Download FSP/Fortron FSP270-60LE power supply unit

Transcript
80 PLUS Verification and Testing Report
83.13%
81.54%
YES
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
326
FSP
FSP270-60LE
NA
2007
CUSTOM
8/6/2007
Input Current and Voltage Waveforms
200
15
150
10
5
50
0
0
-50 0
0.003
0.006
0.009
0.012
0.015
-5
Current (A)
100
Voltage (V)
Ecos ID #
Manufacturer
Model Number
Serial Number
Year
Type
Test Date
-100
Rated Specifications
Input Voltage
Input Current
Input Frequency
Rated Output Power
Value
Units
-150
100-240
5
50-60
300
Volts
Amps
Hz
Watts
-200
PF
0.99
0.99
1.00
ITHD (%)
6.5%
6.3%
4.8%
Load
(%)
20%
50%
100%
Fraction Input
of Load Watts
Light
Typical
Full
74
179
370
-15
Time (s)
Voltage
Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz.
IRMS
A
0.65
1.57
3.22
-10
Current
Input AC Current Waveform (ITHD = 6.31%, 50% Load)
DC Terminal Voltage (V)/ DC Load Current (A)
-12V
3.3V
5V*
12V (cumulative of 12V1, 12V2, etc.)
11.1/0.2 3.3/1.8
5/2
12.1/3.3
12/8.2
11.1/0.4 3.3/4.6
4.9/5.1
11.9/16.3
11/0.8
3.3/9.1 4.9/10.3
Input and Output Power
400
5VSB
5/0.5
4.9/1.2
4.9/2.5
Output
Watts
60
149
296
Efficiency
%
81.45%
83.13%
80.04%
Efficiency of the Power Supply
90%
350
80%
Input Watts
Efficiency (%)
Power (Watts)
300
250
200
150
100
60%
50%
Output Watts
40%
50
0
20%
70%
Efficiency %
30%
50%
Loading (% of Rated Output Power)
100%
0%
25%
50%
75%
100%
Loading (% of Rated Output Power)
These tests were conducted as a part of the 80 PLUS program. 80 PLUS is
a computer buy-down program to promote high-efficiency power supplies
(greater than 80% efficiency in the active mode) in desktop computers and
desktop-derived servers.
Tested by Electric Power Research Institute, Knoxville, TN.
125%