TX6 PLUS and TX5e
Shielded Jack Modules
Part Numbers: CJS688TG, CJS688TGY, CJS5E88TG, CJS5E88TGY
INSTALLATION INSTRUCTIONS PN399A
© Panduit Corp. 2006
FTP / ScTP
Overall Foil
Screen
2.0 in
(50.8 mm)
Conductors
.5 in
(12.7mm)
Drain wire
S-FTP
Overall Foil
Screen
Strain Relief
Collar
2.0 in
(50.8 mm)
Conductors
Braid
CWST
.5 in
(12.7 mm)
STP / PIMF
Individual Foil
Pair Screen
Wire Cap
White - TX6 PLUS
Red - TX5e
2.0 in
(50.8 mm)
Conductors
CWST
Braid
.5 in
(12.7 mm)
Jack
TERMINATION STEPS
2
1
Cable
End 1
3
Cable
End 2
4
"
"
"
"
2
1
Trim pair separator and/or rip cord if
present.
5
Pr3
Pr2
Pr1
Pr4
6
Cable End 2
Cable End 1
Pr4
Pr3
Pr2
Pr1
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 2
INSTALLATION INSTRUCTIONS PN399A
7
8
CWST
T568B
T568A
Cable End 1
Cable End 1
1
9
2
2
1
A
B
3
10
EGJT
Cable End 2
Cable End 2
2
1
11
EGJT
2
A
1
B
3
A
B
3
12
CJSGK-X
KIT
See note 5.
See note 4.
REMOVAL STEPS
1
2
3
Notes:
1. For specified performance, follow TIA/EIA 568-B installation guidelines.
2. Jack Modules can terminate PVC or LSZH rated 22-26 AWG solid or stranded IWC cable with 0.048 inch (1.2 mm)
maximum insulated conductor outside diameter.
3. Jack Modules may be re-terminated a minimum of 20 times.
4. On cable end 2 for A & B wiring and cable end 1 of A wiring, wrap the designated pairs around the proper center dividing post (A or B) and terminate
in the proper location.
5. CJSGK-X Grounding Kit is REQUIRED for all MINI-COM Modular Patch Panels, but is optional for MINI-COM All Metal Shielded Modular Patch Panels.
6. For technical and performance information, consult PANDUIT Technical Support.
As with all Wiring Accessories, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
E-mail: