Download GE Monogram ZV1050SFSS 42" Island Chimney Hood
Transcript
Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com 42" Island Vent Hood Model: ZV1050 Monogram. ® We bring good things to life. 1 Design Information BEFORE YOU BEGIN WARNING: Read these instructions completely and carefully. TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at the service panel and lock service panel to prevent power from being switched on accidentally. If the service panel cannot be locked, fasten a tag or prominent warning label to the panel. • IMPORTANT - Save these instructions for local inspector’s use. • IMPORTANT - Observe all governing codes and ordinances. • Note to Installer - Be sure to leave these instructions with the Consumer. • Note to Consumer - Keep these instructions for future reference. • Skill Level – Installation of this vent hood requires basic mechanical and electrical skills. • Completion time – 1 to 3 hours. • Proper installation is the responsibility of the installer. • Product failure due to improper installation is not covered under the Warranty. ADVERTISSEMENT POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES REGLES SUIVANTES: A. Utiliser cet appareil uniquement de la maniére prévue par le fabricant. En cas de question, consulter le fabricant. B. Avant toute intervention ou nettoyage, couper l’alimentation électrique au disjoncteur et verrouiller le panneau du disjoncteur pour éviter la mise sous tension accidentelle. S’il n’est pas possible de verrouiller le panneau du disconcteur, attacher un placard ou une étiquette trés visible au panneau. • For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors. • Structural framing, installation work and electrical wiring must be done by qualified person(s). In accordance with all applicable codes and standards including fire-rated construction. • Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. • Local codes vary. Installation electrical connections and grounding must comply with applicable codes. In the absence of local codes, the vent should be installed in accordance with National Electrical Code ANSI/NFPA 70-1990 or latest edition. CAUTION: Due to the weight and size of this vent hood and to reduce the risk of personal injury or damage to the product, we recommend at least three people install this hood. PRUDENCE À cause du poids et de la taille de la hotte et pour réduire les risques de blessures ou de dommages de l’équipement, nous recommandons que trois personnes installent cette hotte. WARNING: To reduce the risk of fire or electrical shock, do not use this range hood with any external solid-state speed control device. Any such alteration from original factory wiring could result in damage to the unit and/or create an electrical safety hazard. ADVERTISSEMENT Pour réduire le risque d’incendie ou de choc électrique, il ne faut pas utiliser cette hotte avec un régulateur de vitesse électronique externe. Toute modification de ce type du branchement d’usine peute endommager l’appareil ou créer un risque de choc électrique. CAUTION: To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. PRUDENCE Il faut prendre soin d’installer un conduit vers l’extérieur pour réduire le risque d’incendie et pouvoir évacuer l’air correctement. Il ne faut pas évacuer l’air correctement. Il ne faut pas évacuer l’air dans l’espace entre les parois d’un mur, un plafond ou un grenier, un espace sanitaire ou un garage. 2 Design Information CONTENTS Design Information Product Dimensions ......................................................... 3 Duct Cover Accessories .................................................... 3 Product Clearances .......................................................... 3 Advance Planning Tools and Materials Required .......................................... 4 Power Supply .................................................................... 4 Duct Fittings ...................................................................... 5 Installation Instructions Step 1, Plan the location, Ceiling Support Structure ...................................... 6 Ductwork ................................................................. 7 Step 2, Remove Packaging ............................................... 8 Step 3, Check Installation Hardware ............................... 8 Step 4, Mount Template ................................................... 9 Step 5, Install Support Frame .......................................... 9 Step 6, Secure Wiring ..................................................... 10 Step 7, Size and Install Ductwork .................................. 10 Step 8, Install Decorative Duct Covers .......................... 11 Step 9, Install Hood ........................................................ 11 Step 10, Connect Electrical ............................................ 12 Step 11, Slide Duct Cover Down .................................... 12 Step 12, Install filters, Finalize Installation ................... 13 PRODUCT DIMENSIONS PRODUCT CLEARANCES The vent hood must be installed 25-1/2” min. and 30” max. above the cooking surface. 30” is recommended for 8 ft. ceilings. 30" clearance will insure that the duct cover meets the ceiling. The cooking surface should be at least 36” above the floor. Installation will be easier if the vent hood is installed before the cooktop and countertop is installed. This vent hood is designed to be used in vented ceiling mounted installations. *Height to Ceiling 10" 31-1/2" 42" * 20" to an 8 ft. ceiling. Using supplied duct cover *30" Recommended 32" for 9 ft. Ceiling. Using ZX1059SFSS Accessory 44" for 10 ft. Ceiling Using ZX10510SFSS Accessory This vent hood is supplied with a decorative duct cover to reach 8 ft. ceiling height, or between 7’11" and 8’1". 36" Min. DUCT COVER ACCESSORIES *9 ft. to 10 ft. ceilings may be 25-1/2" to 30" clearance. Order Accessory duct covers for 9 ft. and 10 ft. ceilings. ZX1059SFSS – For 9 ft. ceiling height This kit includes a decorative duct cover and support frame to reach a 9 ft ceiling height. ZX10510SFSS – For 10 ft. ceiling height This kit includes a decorative duct cover and support frame to reach a 10 ft ceiling height. Order the accessory at the same time as the vent hood and have on site before installation begins. *The distance between the cooking surface and the bottom of the hood must be at least 25-1/2". The 30" recommended installation height, above the standard 36” countertop, will insure duct cover fit to the ceiling. For 9 ft and 10 ft. ceilings, the hood may be lowered to 25-1/2" over the cooking surface. IMPORTANT: Clearances may vary due to type of cooking product and local codes. Check with local inspectors to be sure standard is applicable. – When installing the Island Hood above a Monogram Professional Range or Cooktop, installation clearance must be at least 30". 3 Advance Planning TOOLS AND MATERIALS REQUIRED POWER SUPPLY (not supplied) IMPORTANT - (Please read carefully) • Tape measure • Knife • Spirit level • Wire cutter • Wire stripper • Wire nuts • Electric drill and 5/32” bit • Phillips screwdriver • Flat blade screwdriver • Hammer • Pliers • Safety glasses • Tape to mount template • Gloves to protect against sharp edges • 120V 60Hz. 15 or 20 Amp, 2 wire with ground. Properly grounded branch circuit. • Strain relief for junction cover. • Plumb • Center punch WARNING: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. ATTENTION – POUR DES RAISONS DE SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTEMENT MIS À LA TERRE. Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances. Electrical supply This vent hood must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse. • Wiring must be 2 wire with ground. • If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding. • Route house wiring in the ceiling, as close to the installation location as possible. Allow an additional 3 feet length from ceiling joists to reach the junction box on the hood. • Connect the wiring to the house wiring in accordance with local codes. Grounding Instructions The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood. WARNING: The improper connection of equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded. ADVERTISSEMENT Le mauvais branchement du fil de mise à la terre peut causer un choc électrique. En cas de doute, consulter un électricien qualifié ou un technicien pour déterminer si l’appareil est à la terre. 4 Advanced Planning DUCT FITTINGS This Hood Must Use 8" Round Duct It Can Transition to 3-1/4" x 12" Duct Duct Piece Dimensions Round, straight Total Equivalent Quantity Equivalent Length* Used Length 1 ft. (per foot length) 3-1/4" x 12" straight 1 ft. (per foot length) 90° elbow 15 ft. 45° elbow 9 ft. 3-1/4" x 12" 90° elbow 15 ft. 3-1/4" x 12" 45° elbow 9 ft. 3-1/4" x 12" 90° flat elbow 20 ft. Do NOT use flexible plastic ducting. 8" round to 3-1/4" x 24" transition 1 ft. Note: Any home ventilation system, such as a 3-1/4" x 12" to 8" round transition 5 ft. 8" round to 3-1/4" x 12" transition 90° elbow 5 ft. Use this chart to compute maximum permissable lengths for duct runs to outdoors. Note: Do not exceed maximum permissable equivalent lengths! Maximum duct length: 100 foot for range hoods. Flexible ducting: If flexible metal ducting is used, all the equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as much as possible. ventilation hood, may interrupt the proper flow of combustion air and exhaust required by fireplaces, gas furnaces, gas water heaters and other naturally vented systems. To minimize the chance of interruption of such naturally vented systems, follow the heating equipment manufacturer’s guidelines and safety standards such as those published by NFPA and ASHRAE. 3-1/4" x 12" to 8" round transition 90° elbow 15 ft. Round wall cap with damper 30 ft. 3-1/4" x 12" wall cap with damper 30 ft. Round roof cap 26 ft. Round roof vent 24 ft. * Actual length of straight duct plus duct fitting equivalent. Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance with any ventilation hood. 5 Total Duct Run Installation Instructions STEP 1 ADVANCE PLANNING Ceiling Plan the location Determine the exact location of the vent hood. • Use a plumb bob to check location to be sure countertop/cooktop location below the hood will align exactly. • The hood should project forward 1-1/2” beyond the front edge of the cooking appliance. See illustration. • Observe the recommended space (30") between the cooking surface and bottom of hood. Hood Ducting Centerline Hood Front 15-3/4" 31-1/2" Ceiling support structure • At the hood location, install 2 x 4 min. cross framing between ceiling joists as shown. (2x4’s are required to support the weight.) • The 2 x 4 cross framing can be installed standing or flat, depending on duct run. See illustration. Approx. 1-1/2" Beyond Cooking Surface Cooktop Countertop Side View Cross Framing Top View of Support Framing 11-1/4" Cross Framing Ceiling 7-1/4" *7-1/4" 16" Joist Side View Front of Hood Upper Support Frames Typical Support Frame Mounting Lower *The framing should be spaced 7-1/4" on the sides and 11-1/4" at the front centerline to accept mounting screws in the vent support frame. IMPORTANT: The cross framing must be spaced 7-1/4” from centerline to centerline in order to accept the hood mounting screws. 6 Installation Instructions STEP 1 CONTINUED 2x 4 Min. Cross Framing • Arrange cross framing in the ceiling to suit the existing structure. See examples. – Secure each 2 x 4 block with at least four (4), #10 wood screws, 3” long (not supplied). Use 8 wood screws total for the two supports. Ceiling Joist • The cross framing must be accurately aligned to assure correct positioning of the hood. • The cross framing must be level in all directions. Check with a spirit level and adjust if necessary. 7-1/4" 11-1/4" Upper Half Of Support Frame IMPORTANT: The ceiling structure must be capable of supporting the weight of the hood (approximately 300 pounds) and any inadvertent user contact loads. The hood support frame will be supported by the 2 x 4 min. cross framing. Support Frame Opening Front of Hood Height Adjustment Slot Ductwork • Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 100 feet equivalent length for any duct configuration. • Refer to “Duct Fittings” chart to compute the maximum permissible length for duct runs to the outdoors. • This vent hood must use 8” round duct. The 8” round duct can transition to 3-1/4” x 12”. • Install the house ductwork to run horizontally between ceiling joists or straight up through the roof. Ceiling Joint 8" Duct Vent Straight Up Through The Ceiling 2x4 8" Round Duct Elbow Finish the Ceiling • Finish the ceiling surface. Be sure to mark location of the ceiling joists and cross framing. Check to be sure the ceiling is level, use shims if necessary. Flat Standing *Vent Between Ceiling Joists *Depending on available space. 7 Installation Instructions STEP 2 REMOVE THE PACKAGING The vent hood is packed separate from the decorative duct cover or accessory covers ZX1059SFSS or ZX10510SFSS. • Remove the frame, cover, parts box and packaging. • Remove junction box cover. • Install strain relief onto junction box cover. STEP 3 CHECK INSTALLATION HARDWARE Locate the hardware accessory pack shipped with the hood and check contents. 3 Phillips head decorative screws Template 4 Machine Screws 4 Lock Washers 4 Filters 4 Hex Head Lag Screws Service Safety Stop Screw Check service manual envelope taped to the side of the hood to be sure it contains one stop screw. Leave this screw in the envelope. Check contents of the accessory package. Mounting Screw Holes Decorate Duct Covers Support frames with 8 screws and 8 washers Attachment Screw Hole (Left Side) 8 Installation Instruction STEP 4 MOUNT TEMPLATE • Align the template with the marks on the ceiling and tape in place. – Be sure the template is oriented correctly, with the front of the hood. • Use a plumb to check to be sure the mounting holes will provide parallel alignment with the countertop below. • Center punch all hole locations. • Drill pilot holes in the 4 screw locations. Use a 5/32” bit and drill approximately 1-1/2” deep. • Cut the 8-1/4" duct opening and approx. 1" wire access hole. Wire Access Holes STEP 5 INSTALL SUPPORT FRAME Hood Mounting Flange Lower Support 10" Upper Support Frame 40" Front Of Hood 30" Recommended Support Frame Opening 76" Countertop Lower Support Frame Check Level in Both Direction Install upper support frame • Secure the upper support frame to the ceiling joists and cross framing with the 4 lag screws provided. For maximum rigidity and strength, the screws must be driven into the center of the joists and/or cross framing. Check to be sure the support frame is level, vertically and horizontally. Install lower support frame • Insert lower support frame (or accessory support frame, ZX1059SFSS or ZX10510SFSS) into the upper support frame and loosely secure with 8 screws and washers. (4 on the front and 4 on the back sides) • Adjust the lower support frame up or down to the desired height above the countertop. Tighten screws. IMPORTANT: Again, check to be sure the support is level in both directions. There is no way to level the hood after the hood is secured to the frame. 9 Installation Instructions STEP 6 SECURE WIRING STEP 7 SIZE AND INSTALL DUCTWORK • Route house wiring through the ceiling hole and pull a length to reach the hood junction box, approximately 6” below the support. Ceiling Ceiling House Duct Left Side View Side View Support Frame Support Frames Duct Dim. A Required Duct Length Tape Duct Connection To Hood 1-3/4" House Wiring Bottom Support Frame Flange • Measure from house duct flange to bottom of support frame. Dim. A – Add at least 1” for duct overlap at the top. – Subtract 1-3/4” for hood insertion into the bottom of the frame to determine required duct length. • Cut the 8” duct length required. Note: The bottom of the duct must be external (female) connection to the top of the hood. The bottom end should be flared slightly, to facilitate installation of the hood. • Install duct up through support frames and attach to house ducting with sheet metal screws. • Seal the connection with duct tape. • Tape the wire to the left side of the frame support to prevent damage during installation and service. 10 Installation Instructions STEP 8 INSTALL DECORATIVE DUCT COVERS Install Screw on Each Side Pretap 2 Screw Holes (One On Each Side) Top Duct Cover Bottom Duct Cover Bottom Duct Cover Top Duct Cover Top Duct Cover Stop Screw Install Stop Screw in Hole of Upper (Inner) Duct Cover • Slide the lower decorative duct over the installed upper duct and push to the top, keeping the bottom slotted hole to the left. • Install the decorative stop screw in center hole of upper (inner) duct cover. The decorative screw will act as a stop screw and prevent the lower decorative duct cover from sliding down. • Pretap or drive decorative screw into the screw holes on the support frame. This will make screw installation easier. • Separate the two decorative duct covers. • Select the inside cover (top), which has two screw holes in the top. • Slide the decorative duct cover over the support frame and push to the ceiling. • Attach to the hood support at the top with 2 supplied decorative screws. • Locate the 3rd decorative screw in the hardware package. Set aside. CAUTION: The stop screw must be installed. Failure to do so could result in personal injury or damage to the duct cover. PRUDENCE – La vis supérieure doit être en place, afin d’éviter les blessures ou d’endommager le capot antipoussière. STEP 9 INSTALL HOOD Bottom Duct Cover Note: AT LEAST THREE PEOPLE ARE REQUIRED TO COMPLETE THIS INSTALLATION! • Lift the hood up to the support frame. Carefully align the hood mounting holes to support frame holes, and at the same time, the hood duct connector into the duct. • Install screws through the hood and hood support. • Check hood level in both directions. • Check to be sure that the duct is positioned over the hood connector. • Seal the duct connection with duct tape. Stop Screw Install 4 Lock Washers and 4 Machine Bolts Apply Duct Tape to Seal Duct Connection Note: Do not drive screws through this duct connection. Doing so will prevent proper damper operation. 11 Installation Instructions STEP 11 SLIDE DUCT COVER DOWN STEP 10 CONNECT ELECTRICAL Verify that power is turned off at the source. WARNING: If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use UL approved anti-oxidant compound and aluminum-to-copper connectors. Install Decorative Screw ATTENTION – Si le câblage de la maison n’est pas du type à deux fils avec un fil de terre, l’installateur doit fournir un circuit de terre. Quand les fils de la maison sont en aluminium, il prendre soin d’utiliser de la pâte antioxidation approuvée par UL et des connecteurs pour l’aluminium-cuivre. • Hold the decorative duct cover and remove the decorative stop screw from the support frame. Keep the screw. • Slide the lower duct cover down onto the hood. • Install the decorative screw in the lower left hole on the duct cover as shown. • Install strain relief onto the knockout of the junction box cover. • Insert house wiring through strain relief and tighten. • Connect white leads to branch circuit white lead. • Connect black leads to branch circuit black lead. • Connect green/yellow leads to branch circuit green or bare ground lead. • Secure all connections with wire nuts on each electrical connector. • Push wires into junction box and replace cover. Be sure wires are not pinched. 12 Installation Instructions STEP 12 INSTALL FILTERS, FINALIZE INSTALLATION Filter Slots • Remove protective film on the filters. • Tip the filter into the lower slots at the rear of the opening. Lift the filter and pull the knob forward until the filter rests on the slots. • To remove the filters, grasp the knob and push the filter towards the rear and tilt downwards. • Remove the protective film covering the control panel on the front face of the hood, and any other packaging materials. • Check all 4 lamps to assure tightness in sockets. • Refer to the Owner’s Manual for operating instructions. • Clean the hood with an approved stainless steel cleaner. 13 Notes 14 Notes 15 Note: While performing installations described in this book, safety glasses or goggles should be worn. For Monogram® local service in your area, call 1-800-444-1845. Note: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specifications are subject to change without notice. Monogram. ® We bring good things to life. General Electric Company Louisville, KY 40225 Pub. No. 49-80153 Dwg. No. 164D4290P110 (N.D. 538) 11/02 Printed in Italy 16