Download McIntosh C2200 Owner`s manual

Transcript
Owner’s
Manual
C2200 Tube Preamplifier
C2200
McIntosh Laboratory, Inc. 2 Chambers Street Binghamton, New York 13903-2699 Phone: 607-723-3512 FAX: 607-724-0549
IMPORTANT SAFETY INSTRUCTIONS!
PLEASE READ THEM BEFORE OPERATING THIS EQUIPMENT.
The lightning flash with arrowhead, within
an equilateral triangle, is intended to alert
the user to the presence of uninsulated
“dangerous voltage” within the product’s
enclosure that may be of sufficient magnitude to constitute a risk of electric
shock to persons.
WARNING - TO REDUCE RISK OF
FIRE OR ELECTRICAL SHOCK, DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
General:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Warning: To reduce risk of fire or electrical shock,
do not expose this equipment to rain or moisture.
This unit is capable of producing high sound pressure levels. Continued exposure to high sound pressure levels can cause permanent hearing impairment
or loss. User caution is advised and ear protection is
recommended when playing at high volumes.
6. Caution: to prevent electrical shock do not use this
(polarized) plug with an extension cord, receptacle or
other outlet unless the blades can be fully inserted to
prevent blade exposure.
Attention: pour pevenir les chocs elecriques pas
utiliser cette fiche polarisee avec un prolongateur,
une prise de courant ou un autre sortie de courant,
sauf si les lames peuvent etre inserees afond ans en
laisser aucune partie a decouvert.
7. Unplug this equipment during lightning storms or when
unused for long periods of time.
8. Only use attachments/accessories specified by the
manufacturer.
2
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
NO USER-SERVICEABLE PARTS
INSIDE. REFER SERVICING TO
QUALIFIED PERSONNEL.
To prevent the risk of electric shock, do not remove cover or
back. No user serviceable parts inside.
Installation:
9. The equipment shall be installed near the AC Socket
Outlet and the disconnect device shall be easily accessible.
10. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
11. Do not install near any heat sources such as radiators,
heat registers, stoves, or other equipment (including amplifiers) that produce heat.
12. Do not use this equipment near water.
13. Do not expose this equipment to dripping
or splashing and ensure that no objects
filled with liquids, such as vases, are
placed on the equipment.
14. Use only with the cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the equipment. When a cart is used, use caution when moving the
cart/equipment combination to avoid injury from tipover.
Connection:
15. Connect this equipment only to the type of AC power
source as marked on the unit.
16. Protect the power cord from being walked on or
pinched particularly at plugs, convenience receptacles,
and the point where they exit from the equipment.
17. Do not defeat the safety purpose of the polarized or
grounding-type plug.
A polarized plug has two blades with one wider
than the other. A grounding type plug has two
blades and a third grounding prong. The wide blade
or the third prong are provided for your safety. If
the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete
outlet.
18. Do not overload wall outlets, extension cords or integral convenience receptacles as this can result in a risk
of fire or electric shock.
19. To completely disconnect this equipment from the AC
Mains, disconnect the power supply cord plug from the
AC receptacle.
Care of Equipment:
20. Clean only with a dry cloth.
21. Do not permit objects or liquids of any kind to be
pushed, spilled and/or fall into the equipment through
enclosure openings.
22. Unplug the power cord from the AC power outlet when
left unused for a long period of time.
Repair of Equipment:
23. Refer all servicing to qualified service personnel. Servicing is required when the equipment has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen
into the equipment, the equipment has been exposed to
rain or moisture, does not operate normally, or has been
dropped.
24. Do not attempt to service beyond that described in the
operating instructions. All other service should be referred to qualified service personnel.
25. When replacement parts are required, be sure the service technician has used replacement parts specified by
McIntosh or have the same characteristics as the original part. Unauthorized substitutions may result in fire,
electric shock, or other hazards.
26. Upon completion of any service or repairs to this product, ask the service technician to perform safety checks
to determine that the product is in proper operating condition.
Thank You
Your decision to own this McIntosh C2200 Tube Preamplifier ranks you at the very top among discriminating music
listeners. You now have “The Best.” The McIntosh dedication to “Quality,” is assurance that you will receive many
years of musical enjoyment from this unit.
Please take a short time to read the information in this
manual. We want you to be as familiar as possible with all
the features and functions of your new McIntosh.
Please Take A Moment
The serial number, purchase date and McIntosh Dealer
name are important to you for possible insurance claim or
future service. The spaces below have been provided for
you to record that information:
Serial Number:
Purchase Date:
Dealer Name:
Technical Assistance
If at any time you have questions about your McIntosh
product, contact your McIntosh Dealer who is familiar with
your McIntosh equipment and any other brands that may be
part of your system. If you or your Dealer wish additional
help concerning a suspected problem, you can receive technical assistance for all McIntosh products at:
McIntosh Laboratory, Inc.
2 Chambers Street
Binghamton, New York 13903
Phone: 607-723-1545
Fax: 607-723-3636
Customer Service
If it is determined that your McIntosh product is in need of
repair, you can return it to your Dealer. You can also return
it to the McIntosh Laboratory Service Department. For assistance on factory repair return procedure, contact the
McIntosh Service Department at:
McIntosh Laboratory, Inc.
2 Chambers Street
Binghamton, New York 13903
Phone: 607-723-3515
Fax: 607-723-1917
Copyright 2001  by McIntosh Laboratory, Inc.
3
Table of Contents
Safety Instructions ............................................................ 2
Thank You and Please Take a Moment ............................. 3
Technical Assistance and Customer Service ..................... 3
Table of Contents and General Notes ................................ 4
Connector Information ...................................................... 4
Introduction ....................................................................... 5
Performance Features ....................................................... 5
Dimensions ........................................................................ 6
Installation ........................................................................ 7
Connections
Rear Panel Connections ..................................................... 8
How to Connect for Power Control ................................... 9
How to Connect for Audio and Data Control ................... 10
How to Connect for Pass Thru Mode .............................. 11
How to Connect for a Second Room ................................ 12
Front Panel Features
Front Panel Controls, Displays, Push-buttons,
and Switches .................................................................... 13
Setup
How to Operate the Setup Mode ...................................... 14
Default Settings ................................................................ 14
Display Brightness ........................................................... 14
Input Trim Level .............................................................. 15
Re-Title Inputs ................................................................. 15
Power Control Triggers .................................................... 16
Auto Tone......................................................................... 16
Pass Thru Mode ............................................................... 17
Power On Option ............................................................. 17
Remote Control Selection ................................................ 17
Firmware Version ............................................................. 18
Operation
How to Operate the C2200 .............................................. 19
Remote Control Push-buttons .......................................... 22
How to Operate by Remote Control ................................. 23
Additional Information
Technical Description....................................................... 24
Specifications ................................................................... 26
Packing Instruction .......................................................... 27
General Notes
1. The C2200 uses Vacuum Tubes for amplifying the audio
signal. The C2200 is designed to have only qualified
Service Personnel perform any part(s) replacement
including all the vacuum tubes.
2. For additional information on Audio Connections, refer to
the Owner’s Manual(s) for the component(s).
3. Connecting Cables and Connectors are available from the
McIntosh Parts Department:
Data and Power Control Cable Part No. 170-202
Six foot, shielded 2 conductor, with 1/8 inch stereo mini
phone plug on each end.
4
4. The Main AC Power going to the C2200 and any other
McIntosh Component(s) should not be applied until all the
system components are connected together. When the
C2200 and other McIntosh Components are in their
Standby Power Off Mode, the Microprocessor’s Circuitry
inside each component is active and communication is
occurring between them. Failure to do so could result in
malfunctioning of some or all of the system’s normal
operations.
5. Up to four Sensors can be wired in parallel for Remote
Control of the C2200 from other rooms.
6. Balanced and Unbalanced Inputs and Outputs can be
mixed. For example, you may connect signal sources to
Unbalanced Inputs and send signals from the Balanced
Outputs. You can also use Balanced and Unbalanced
Outputs simultaneously, connected to different Power
Amplifiers.
7. A McIntosh Power Controller may be added to the C2200 to
provide AC Power Switching to components that do not
have Power Control Connections. See your McIntosh
Dealer for additional information.
8. Sound Intensity is measured in units called Decibels and
“dB” is the abbreviation.
9. The PHONO Circuitry uses four Vacuum Tubes. Those tubes
are only Powered-On (glow coming from the tubes) when
the AUX Input is re-titled to PHONO in the Setup Mode.
Refer to page 15 “Re-Titled Inputs” for additional
information.
Connector Information
XLR Connectors
Below is the Pin configuration for the XLR Balanced Input
and Output Connectors on the C2200. Refer to the diagram
for connection:
Pin 2
PIN 1: Shield/Ground
PIN 2: + Input
Pin 1
PIN 3: - Input
Pin 3
Power Control and Trigger Connectors
The C2200’s Power Control Outputs provide a 5 volt signal. Use a 1/8 inch stereo mini
phone plug to connect to the
Positive
Power Control Input on other
N/C
McIntosh Components.
Ground
Data Port Connector
The C2200’s Data Port Output provides Remote Control
Signals. Use a 1/8 inch stereo mini
phone plug to connect to the Data Data Signal
Port Inputs on McIntosh Source
N/C
Units.
Ground
Introduction and Performance Features
Introduction
The McIntosh C2200 Tube Preamplifier is without question
the finest Audio Tube Preamplifier ever created. No design
compromises were allowed in the quest for a Tube Preamplifier with absolute accuracy, total sonic purity and virtual
elimination of distortion and audible noise. For those who
have been searching for their “Last Tube Preamplifier”,
your search is over.
•
Performance Features
•
•
Balanced Inputs and Outputs
Four balanced high level Inputs and three balanced Outputs
are provided.
•
Precision Tracking Volume Control
Volume levels are controlled by a new Multi-Stage Precision
Digitally Controlled Attenuator System with a tracking accuracy of 0.1dB. Levels change in 214 individual 0.5dB
steps.
•
Variable Rate Volume and Balance Control Selection
The C2200 Tube Preamplifier’s Volume and Balance Control Circuitry provides an ideal rate of change with control
rotation.
•
Tone Control with Assignable Bypass
The Bass and Treble Control Circuit Elements can be removed from the Signal Path of any selected input.
•
Alphanumeric Fluorescent Display
The Multifunction Front Panel Display indicates the Source
Selection, Volume and Balance Levels. Setup Mode Selections and Adjustments are also displayed. The display intensity is fully adjustable.
•
Electromagentic Input Switching with Level Trim
Adjustment and Title Reassignment
Digital Logic integrated circuits drive Electromagnetic
Switches on all Inputs and operating functions for reliable,
noiseless, distortion free switching. All eight Inputs on the
C2200 can be matched in level, so that there are no abrupt
changes in volume levels between the different Inputs. There
is also a Record Monitor function for checking the progress
of a recording. Any of the eight Inputs can have their Input
Title reassigned to match the sources in the system.
Precision Parts
Only the finest precision 1% tolerance resistors are used
throughout.
•
Low Distortion
Distortion levels of all types are less than 0.08%. Music is
amplified with total transparency and accuracy.
Moving Magnet Phono Input
There is a Precision Phono Preamplifier for Moving Magnet
Cartridges.
•
Multichannel Pass Thru Mode
The Input Assignable, Automatic Pass Thru Mode allows
the C2200 to become part of a Multichannel Sound System
for DVD-Audio, SACD and Home Theater. The Left and
Right Channels of the C2200 become the two front channels, simply by turning on the Multichannel Processor.
•
Remote Control
The C2200 includes a Remote Control that allows remote
operation of the Front Panel Controls and Push-buttons.
•
Optional External Sensor Input
There are provisions for connecting External Sensors,
which allows for enjoyment of your McIntosh System from
other room(s) in your home via the Remote Control.
•
Output Switching
Front panel Output Push-buttons control two Switched Outputs that allow sending signals to two separate Power Amplifiers.
•
Power Control Output and Trigger Assignment
A Power Control connection for convenient Turn-On of
McIntosh Power Amplifiers, Source Components and Accessories is included. Three of the Power Control Ouputs
may be assigned to activate when a given Input is selected.
5
Dimensions
Dimensions
The following dimensions can assist in determining the best
location for your C2200. There is additional information on
the next page pertaining to installing the C2200 into cabinets.
17-1/2"
44.45cm
Front View of the C2200
7 -1/8"
18.10cm
7 -5/8"
19.37cm
17"
43.18cm
Rear View of the C2200
6 -5/16"
16.03cm
13 -1/4"
33.66cm
16-3/16"
41.43cm
15-1/2"
39.37cm
Side View of the C2200
6-1/2"
3/16"
0.48cm 16.51cm
13/16"
2.06cm
10-1/2"
26.67cm
6
2"
5.08cm
Installation
Installation
The C2200 can be placed upright on a table or shelf, standinches (5.08cm) above the top, 2 inches (5.08cm) below the
ing on its four feet. It also can be custom installed in a piece bottom and 1 inch (2.54cm) on each side of the A/V Control
of furniture or cabinet of your choice. The four feet may be
Center, so that airflow is not obstructed. Allow 19-1/2
removed from the bottom of the C2200 when it is custom
inches (49.53cm) depth behind the front panel. Allow 1-1/8
installed as outlined below. The four feet together with the
inch (2.9cm) in front of the mounting panel for knob clearmounting screws should be retained for possible future use
ance. Be sure to cut out a ventilation hole in the mounting
if the C2200 is removed from the custom installation and
shelf according to the dimensions in the drawing.
used free standing. The required
panel cutout, ventilation cutout
and unit dimensions are shown.
17-1/16"
43.34cm
Always provide adequate
ventilation for your C2200. Cool
operation ensures the longest
possible operating life for any
C2200
electronic instrument. Do not
6 -5/8"
Front Panel
16.83cm
install the C2200 directly above
Custom Cabinet
Cutout
a heat generating component
such as a high powered amplifier. If all the components are
installed in a single cabinet, a
Cutout Opening for Custom Mounting
quiet running ventilation fan can
Cabinet
2"
be a definite asset in maintaining
Front
5.08cm
Panel
all the system components at the
coolest possible operating temOpening for
perature.
Ventilation
A custom cabinet installation
C2200
should provide the following
Side View in a
minimum spacing dimensions for
Partially Open
cool operation. Allow at least 2
Custom Cabinet
Enclosed Custom Cabinet
Ventilaton Fan
Support
Shelf
Warm Air
Output
Other Component
in Enclosed
Custom Cabinet
Cutout Opening for Ventilation
5-3/4"
14.61cm
Chassis
Spacers
6-1/2"
16.51cm
C2200
Support Shelf in
Custom Cabinet
Cutout Opening for Ventilation
Cutout
Opening
for
Ventilation
12"
30.48cm
13-1/4"
33.66cm
C2200
Side View
in Enclosed
Custom Cabinet
Cutout Opening for Ventilation
Chassis
Spacers
Cool Air
Input
Ventilaton Fan
10-1/2"
26.67cm
Notes: Center the Cutout Horitzonally on unit.
For purposes of clarity, the above
illustration is not drawn to scale.
7
Rear Panel Connections
Unbalanced MAIN OUTPUTS contain the program
signals at all times. The Unbalanced 1 and 2 OUTPUTS
contain the program signals
and turn On/Off with the
Front Panel OUTPUTS 1 and
2 Push-buttons
TAPE/REC OUTPUTS contain
RECord Out Signals
Balanced MAIN OUTPUTS
contain the program signals
at all times. The Balanced 1
and 2 OUTPUTS and can be
switched On/Off with the
Front Panel OUTPUTS 1 and
2 Push-buttons
Connect the
power cord to a
live AC outlet.
Refer to information on the back
panel of the
C2200 to determine the correct
voltage
Main Fuse holder,
refer to information
on the back panel of
the C2200 to determine the correct
fuse size and rating
8
VCR, SAT, DVD and CD Balanced INPUTS accept high
level program source signals
TAPE/REC, VCR, SAT, DVD,
CD, CD2 and TUNER unbalanced INPUTS accept high
level program source signals
POWER CONTROL/TRIGGERS Outputs send Turn-On
signals to other components
connected to the C2200. The
MAIN Jack sends the signal
when the C2200 is switched
On. The 1 and 2 Jacks send
the signal when the OUTPUTS 1 and 2 Push-buttons
are active. The ACCessory
Jack is for sending the signal
to McIntosh Source Components. The SETUP Feature in
the C2200 allows the ACC, 1
and 2 Power Control Jacks to
be re-assigned to Switch On
when the desired Input Source
is selected.
The EXTernal
SENSOR Jack
permits the connection of a
McIntosh IR Sensor for remote
operation
PASS THRU Power
Control input receives
a Turn-On signal
from a McIntosh
Home Theater Controller
Gound connection
for turntables
PH/AUX accepts high
level program source signals or signals from a
Moving Magnet Phono
Cartridge. The SETUP
feature determines
whether the Input Jacks
are set for AUX or
PHONO
DATA PORTS send
control signals to
compatible source
components and allow
Remote Control operation
How to Connect for Power Control
How to Connect for Power Control
The four Power Control Jacks have default settings as explained on page 8. The hookup example below utilizing the
default settings. If you wish to use any one of the three assignable Power Control Outputs as a dedicated Trigger instead, connect that Component Source Unit’s Power Control
Input to the desired Trigger Output (A, B, or C). The default setting in the C2200 Setup needs to be changed to
match the new Power Control Connection.
1. Connect a Control Cable from the C2200 POWER
CONTROL ACCessory Jack to the Power Control In
McIntosh CD Player
on the McIntosh CD Player.
2. Connect a Control Cable from the McIntosh CD Player
Power Control Out Jack to the Power Control In Jack
on the McIntosh Tuner.
3. Connect a Control Cable from the McIntosh Tuner
Power Control Out Jack to the Power Control Jack on
the McIntosh Power Control.
4. Connect a Control Cable from the C2200 MAIN
POWER CONTROL Jack to the Power Control In Jack
on the McIntosh Power Amplifier.
McIntosh AM/FM Tuner
McIntosh Power Amplifier
McIntosh
Power Control
9
How to Connect for Audio and Data Control
How to Connect for Audio and Data Control
1. Connect Audio Cables from the McIntosh C2200
MAIN Balanced OUTPUTS to the McIntosh Power
Amplifier Balanced INPUTS.
Note: The unbalanced MAIN Audio Outputs and unbalanced
Power Amplifier Inputs may be used instead of the
Balanced Connections.
2. Connect Audio Cables from the McIntosh CD Player
Balanced Audio Outputs to the C2200 CD Balanced
INPUTS.
Note: The unbalanced Audio Outputs and Inputs may be used
instead of the Balanced Connections.
3. Connect an Audio Cable from a McIntosh Tuner 1 Outputs to the C2200 TUNER INPUTS.
4. Connect an Audio Cable from a Turntable to the PH/
AUX INPUTS and the Turntable Ground Connection to
the GND grounding post.
5. Connect an Audio Cable from the C2200 TAPE/REC
OUTPUTS to the Record Inputs of a Tape Recorder
and from the C2200 TAPE INPUTS to a Tape Recorder
Outputs.
6. Connect a Control Cable from the C2200 CD DATA
PORT Jack to the DATA IN Jack on the McIntosh CD
Player.
7. Connect a Control Cable from the C2200 TUNER
DATA PORT Jack to the DATA IN Jack on the McIntosh Tuner.
Note: By adding a McIntosh Remote Control Translator to
the C2200, non McIntosh Source Devices such as a
Satellite Receiver can be remotely controlled using a
McIntosh Remote Control and Keypad/Sensor.
8. Connect the C2200 Power Cord to a live AC outlet.
McIntosh AM/FM Tuner
McIntosh CD Player
To AC Outlet
McIntosh Power Amplifier
Turntable
in
10
Tape Deck
out
How to Connect for Pass Thru Mode
How to Connect for Pass Thru Mode
The PASS THRU Mode on the C2200 allows it to be part
of a Multichannel System for the Left and Right Front
Channels, when it is connected to a McIntosh Multichannel
Processor such as the MX134.
Any of the C2200’s High Level Inputs may be used for
the PASS THRU Function. The C2200 default setting for
the PASS THRU feature needs to be changed in Setup.
Connect the basic system as outlined in the two previous
pages and then add the two following connections. The example below uses the AUX Input for the PASS THRU
Mode.
1. Connect a Power Control Cable from the McIntosh A/V
Controller Power Control Zone A to the C2200 PASS
THRU Jack.
2. Connect an Audio Cable from the McIntosh A/V Controller Zone A Front Left and Right Audio Outputs to
the C2200 AUX 1 INPUTS.
McIntosh A/V Control Center
11
How to Connect for a Second Room
How to Connect for a Second Room
1. Connect Audio Cables from the C2200 Balanced OUTPUTS 2 to the Second Power Amplifier Balanced Inputs.
Notes: The unbalanced Audio OUTPUTS 2 and unbalanced
Power Amplifier Inputs may be used instead of the
Balanced Connections. When a second room is
connected, it is sometimes desirable to switch Off the
Loudspeakers in the Main Listening Room. This can be
accomplished by connecting the Main Power Amplifier
to the C2200 OUTPUTS 1 instead of the MAIN
OUTPUTS, so that they can be switched Off by the
Front Panel OUTPUTS 1 Push-button.
3. Connect an RG6 or RG59U coaxial cable from the
EXTernal SENSOR Jack to a Keypad.
Note: A Wall Mounted IR Sensor may also be used in place
of the Keypad.
Keypad
2. Connect a Control Cable from the C2200 POWER
CONTROL 2 Jack to the Power Control In of a McIntosh Power Amplifier.
McIntosh Power Amplifier
Right
Loudspeaker
4 ohms
12
Left
Loudspeaker
4 ohms
Front Panel Controls, Displays, Push-Buttons, and Switches
INPUT Switch selects
the Program Source
Signals and is used in
Setup Mode
BASS Control
provides 12dB
boost or cut
with a flat center position
TREBLE Control
provides 12dB
boost or cut with a
flat center position
TONE BYPASS with
indicator, when activated the audio signal
totally bypasses the
Tone Control Circuitry
IR Sensor for
Remote Control Operation
MONO Push-button
with indicator, combines Left and Right
Stereo Signals to
Mono
REC MONITOR
Push-button with
indicator, allows
listening to the
playback of REC/
TAPE Source while
the recording is in
process
METERS indicate the
Preamplifier’s Left and
Right Channels Relative
Output Level
HEADPHONE
Jack accepts
dynamic headphones
SETUP Mode Push-button
with indicator, allows the
changing of the default
settings for Inputs, Levels,
Special Functions and the
Display
VOLUME Control adjusts the listening volume level and is used
for setup functions
DISPLAY indicates the
Sources, Volume/Balance Levels, Operational
Functions and Setup
Mode Settings
METER LIGHTS
Switches the Meter
Illumination On or
Off, and is used in
the Setup Mode
OUTPUTS 1 and
2 Push-buttons
with indicators,
allow the C2200
to switch Power
Control and Audio to two separate Stereo Power
Amplifiers
MUTE Push-button
mutes audio in
MAIN, OUTPUTS
1&2 and HEADPHONES
BALANCE Control
allows the adjustment
of the relative volume
levels for each channel
and is used for setup
functions
POWER
Switch turns
all AC power
completely On
or Off
STANDBY/ON Push-button
turns the C2200 On, or Off
(Standby). The LED Indicator illuminates when there is
incoming AC Power
13
How to Operate the Setup Mode
Default Settings
Your McIntosh C2200 has been factory configured for default operating settings that will allow immediate enjoyment
of superb audio without the need for further adjustments. If
you wish to make changes to the factory default settings, a
Setup Feature is provided to customize the operating settings using the Front Panel Alphanumeric Display.
1. Press the POWER Switch to ON, the Red LED above
the STANDBY/ON Push-button lights to indicate the
C2200 is in Standby mode. To switch On the C2200
press the STANDBY/ON Push-button and wait until
the tube warmup period is over. Refer to figure 3.
2. Press the C2200 Front Panel SETUP Push-button. The
LED above the SETUP Push-button will illuminate and
the Front Panel Display will indicate DISPLAY 20. Refer to figure 1.
The following listings indicate the default settings and the
page number for instructions on how to change a setting.
Setup Function Name
Setting Page Number
Alphanumeric Display Brightness:
Meters Illumnation On
20
14
Meters Illumnation Off
5
14
Trim (Input Level)
00
14
Input Titles
14
Triggers
Off
16
Auto Tone
Off
16
Pass Thru (Multichannel)
Off
16
Power On
16
Remote (Control Type)
Norm
17
Version (C2200 Firmware)
_.__
17
Note: The Front Panel Display will indicate DISPLAY 20
the first time, after then it will display whatever
Setup Mode was last accessed.
Figure 1
3. Rotate the Front Panel METER LIGHTS (Menu) Control and notice that the Setup Mode advances through
eight different possible adjustment selections and one
informational display.
4. To exit from a specific Setup Mode, press the SETUP
Push-button a second time. The LED above the SETUP
Push-button will extinguish and the Front Panel Display
will revert back to its normal display. Refer to figure 2.
Display Brightness
The Front Panel Alphanumeric DISPLAY Brightness may
be varied from a setting of 1(Dim) to 31(Bright) with two
settings, one with the Meter Illumination On and the other
with the Illumination Off. Follow the steps below for changing the brightness. Refer to figure 4.
Figure 2
Figure 3
14
Figure 4
1. Press the SETUP Push-button to access the Setup
Mode.
2. Rotate the Front Panel METER LIGHTS (Menu) Control until the word DISPLAY 20 appears.
3. Rotate the BALANCE (Select) Control until the desired
Display Brightness is achieved. This sets the Brightness
Level with the Meters Illumination On.
Setup
4. Press the SETUP Push-button to exit the Setup Mode.
To set the Front Panel Alphanumeric DISPLAY Brightness
when the Meter Illumination is Off, perform the following
steps.
5. Rotate the Front Panel METER LIGHTS (Menu) to
switch Off the Meter Illumination.
6. Press the SETUP Push-button to access the Setup
Mode.
7. Rotate the Front Panel METER LIGHTS (Menu) Control until the word DISPLAY 5 appears.
8. Rotate the BALANCE (Select) Control until the desired
Display Brightness is achieved. This sets the Brightness
Level with the Meters Illumination Off.
9. Press the SETUP Push-button to exit the Setup Mode.
Input Trim Level
Various Source Components can have slightly different volume levels. This could result in the constant need to readjust
the C2200 Volume Control when switching between different Input Sources. A Volume Trim Feature on the C2200
allows the adjustment of levels for each of the Source Inputs, so that they have the same relative volume. The Tuner
and CD Inputs are used in the following example.
Notes: The possible range of adjustment in volume level is
± 6dB. The Tape/Record Output Levels are uneffected
by any changes in the Trim Settings. Any TRIM
adjustments made are retained in permanent memory
and can be changed only by performing a new TRIM
procedure. The Tuner Input Volume Level can serve as
a reference or choose another Input Source that is
frequently listened to as the reference. The reference
Input Source should be set to a Trim Level of 00.
1. Rotate the INPUT Control to select the Tuner Input and
adjust the VOLUME Control to the desired listening
level.
2. Press the SETUP Push-button to access the Setup
Mode.
3. The Front Panel Alphanumeric Display will change and
the Red LED above the SETUP Push-button will be illuminated.
4. Rotate the METER LIGHTS (Menu) Control until the
words TRIM 00 TUN appears. Refer to figure 5.
Figure 6
6. Rotate the VOLUME Control until the Volume Level of
the CD Input is the same as the Tuner Volume Level.
Refer to figure 7. Figure 7 indicates a 2.5dB decrease in
the CD Level.
Figure 7
7. Rotate the INPUT Control until the next desired Input
Source Name is displayed.
8. Repeat steps 5, 6 and 7 until all the Inputs with sources
connected to the C2200 have the same relative volume
levels when switching between them.
9. Press the SETUP Push-button to exit the Setup Mode.
Note: The Trim Level can also be set via the Remote
Control. A table has been provided on page 17 to
record the changes to the various inputs from the
default settings.
Re-Title Inputs
The C2200 has eight Audio Inputs. These inputs already
have assigned titles that will allow for immediate hookup,
operation and enjoyment.
If these starting assignments do not match up with components in your system, they may be reassigned from the
default settings. The following example will illustrate how
to rename the AUX Input to PHONO. When the Input Selector is rotated to select what was originally the AUX Input, PHONO will now appear on the Front Panel Alphanumeric Display and Power is now supplied to the Vacuum
Tubes in Phono Circuitry.
Notes: 1. Unused Inputs may be switched Off so they will not
appear when rotating through the input source
choices using the Input Selector and also will not be
available when using the Remote Control or Keypad.
Refer to figure 8.
2. The New Input Titles that are available for all the
Inputs (except for the AUX Input) includes TAPE 2,
LV, TV, and VCR2. The AUX Input Titles include
TAPE 2, LV, TV and PHONO.
Figure 5
5. Rotate the INPUT Control until the words TRIM 00
CD appears. Refer to figure 6.
Figure 8
15
1. Press the SETUP Push-button to access the Setup
Mode.
2. The Front Panel Alphanumeric Display will change and
the Red LED above the SETUP Push-button be illuminated.
3. Rotate the METER LIGHTS (Menu) Control until the
words INP AUX>AUX appears. Refer to figure 9.
Note: If another Input Title is displayed, rotate the INPUT
Control to Select the AUX Input
5. Rotate the METER LIGHTS (Menu) Control until the
words TRIG PHONO>- - appears. Refer to figure 13.
Note: If another Input Title is displayed, rotate the INPUT
Control to Select the PHONO Input
Figure 13
6. Rotate the BALANCE (Select) Control until the Front
Panel Alphanumeric Display indicates TRIG PHONO>
B. Refer to figure 14.
Figure 9
4. Rotate the BALANCE (Select) Control until the Front
Panel Alphanumeric Display indicates INP AUX>PH.
Refer to figure 10.
Figure 14
7. Press the SETUP Push-button to exit the Setup Mode.
Auto Tone
Figure 10
5. Press the SETUP Push-button to exit the Setup Mode.
Power Control Triggers
Three of the C2200 Power Control Outputs are reassignable
from their default settings, allowing for various fuinctions
such as activating only when a given Input is selected.
In the following example the Power Control OUTPUT 2
Jack will be reassigned to function as TRIGGER B for the
PHONO Input.
1. Press the SETUP Push-button to access the Setup
Mode.
2. The Front Panel Alphanumeric Display will change and
the Red LED above the SETUP Push-button will be illuminated.
3. Rotate the METER LIGHTS (Menu) Control until the
words TRIG OUT2 > B appears. Refer to figure 11.
Note: If another TRIG Title is displayed, rotate the INPUT
Control to Select OUT2.
Figure 11
4. Rotate the BALANCE (Select) Control until the Front
Panel Alphanumeric Display indicates TRIG OUT2 >
- - . Refer to figure 12.
Figure 12
16
The Auto Tone Feature activates the TONE BYPASS Dynamic Memory Circuit. When the Auto Tone Feature is set
to the On position, the C2200 will automatically remember
for each Input whenever the Tone Bypass Circuit is On or
Off.
1. Press the SETUP Push-button to access the Setup
Mode.
2. The Front Panel Alphanumeric Display will change and
the Red LED above the SETUP Push-button will be illuminated.
3. Rotate the METER LIGHTS (Menu) Control until the
words AUTOTONE OFF appears. Refer to figure 15.
Figure 15
4. Rotate the BALANCE (Select) Control until the Front
Panel Alphanumeric Display indicates AUTOTONE
ON. Refer to figure 16.
Figure 16
5. Press the SETUP Push-button to exit the Setup Mode.
Setup, con’t
Pass Thru Mode
The C2200 can be part of a Multichannel Sound System.
The Right and Left Front Channels from a McIntosh Processor or Decoder can “Pass Thru” the C2200 and on to its
associated Power Amplifier(s). The Setup Mode allows the
Selection of the Input that will be used for the Right and
Left Front Channels Pass Thru Mode. In the example below, the Right and Left Front Channels from the Multichannel Processor/Decoder will be connected to the AUX Input
on the C2200.
1. Press the SETUP Push-button to access the Setup
Mode.
2. Rotate the BALANCE Control Knob until the words
PASSTHRU OFF appears. Refer to figure 17.
Figure 17
3. Rotate the INPUT Control until the Front Panel Alphanumeric Display indicates PASSTHRU AUX. Refer to
figure 18.
4. Rotate the BALANCE (Select) Control until the Front
Panel Alphanumeric Display indicates POWERON
AUTO. Refer to figure 20.
Figure 20
Remote Control Selection
There are two choices for the Remote Control Codes the
C2200 will respond to. The Remote Control included with
the C2200 utilizes the NORMal McIntosh Control Codes.
The Second Set of Control Codes the C2200 will respond to
is referred to as the ALTernate Codes. The ALTernate Codes
are for when the C2200 is used together with a McIntosh
Multichannel Processor/Decoder in the Pass Thru Mode
Hookup. This will prevent the Remote Control from affecting the operation of both units at the same time.
Note: If the ALT Remote Control Code is selected, the C2200
will not respond using the supplied McIntosh Remote
Control.
Figure 18
4. Press the SETUP Push-button to exit the Setup Mode.
Power On Option
The Power On Option Feature permits using the Main
POWER Switch instead of the STANDBY/ON Push-button
for switching the C2200 Preamplifier On or Off.
Note: If the Power On Option is switched to the AUTO Mode
and the Main POWER Switch is in the Off position, the
Front Panel STANDBY/ON Push-button and the
Remote Control POWER Push-button will be unable to
switch Power On to the C2200.
1. Press the SETUP Push-button to access the Setup
Mode.
2. The Red LED above the SETUP Push-button will illuminate.
3. Rotate the Front Panel METER LIGHTS (Menu) Control until the Front Panel Alphanumeric Display indicates POWERON STBY. Refer to figure 19.
1. Press the SETUP Push-button to access the Setup
Mode.
2. The Front Panel Alphanumeric Display will change and
the Red LED above the SETUP Push-button will be illuminated.
3. Rotate the Front Panel METER LIGHTS (Menu) Control until the words REMOTE NORM appears. Refer
to figure 21.
Figure 21
4. Rotate the Front Panel BALANCE (Select) Control until the Front Panel Alphanumeric Display indicates REMOTE ALT. Refer to figure 22.
Figure 22
5. Press the SETUP Push-button to exit the Setup Mode.
Figure 19
17
Setup, con’t
Firmware Version
The C2200 functionality is controlled by internal software
that is know as Firmware. The Version of the Firmware in
the C2200 can be identified at any time by utilizing the
Setup Mode.
1. Press the SETUP Push-button to access the Setup
Mode.
2. Rotate the Front Panel METER LIGHTS (Menu) Control until the word VERSION _. _ _ appears. Refer to
figure 23.
Figure 23
3. The number after the word VERSION is the Firmware
number.
4. Press the SETUP Push-button to exit the Setup Mode.
Input Source Settings
Default Title
AUX
TUNER
CD2
CD
DVD
SAT
VCR
TAPE
18
New Title
Trim
Trigger
How to Operate the C2200
How to Operate the C2200
The McIntosh C2200 Tube Preamplifier has been factory
configured for operating settings that allow immediate enjoyment of superb high fidelity audio without the need for
further adjustments. If you wish to make changes to the factory default settings, refer to the SETUP Section of this
Owner’s Manual.
Power On and Off
Press the POWER switch to ON, the Red LED above the
STANDBY/ON Push-button lights to indicate the C2200 is
in Standby Mode. To Switch On the C2200 press the
STANDBY/ON Push-button. The title TUBE WARMUP
will appear on the Front Panel Alphanumeric Display after
Turn-On, with the Audio Outputs muted. Refer to figures
24, 25 and 26.
Notes: For normal operation, switch the C2200 On and Off
with the Standby/On Push-button. You may also turn
On the C2200 by simply pressing the Power Pushbutton on the Remote Control. If the Preamplifier is
not going to be used for an extended period of time,
turn Off all AC Power with the Power Switch.
The amount of time the Front Panel Alphanumeric
Display indicates TUBE WARMUP is dependant
upon the temperature of the Tubes inside the C2200.
Figure 24
Input Source Selection
Select the desired Source with the INPUT Control or the
Source Push-button on the Remote Control.
Volume Control
Adjust the VOLUME Control
or the Up /Down Pushbuttons on the Remote Control
for the desired listening level.
Record Monitor
Press the REC MONITOR
Push-button to hear the TAPE/
REC Playback Signal during
the recording process.
Tone Bypass
Press the TONE BYPASS
Push-button to totally Bypass
the Tone Control Circuitry, providing a flat frequency response. If the AUTOTONE circuit is set to the On position in
Setup Mode, the C2200 will
remember for each input
whether the Tone Bypass is active.
Bass and Treble Controls
Adjust the BASS and TREBLE
controls to suit your listening
preferences. The Bass or Treble
intensity can be increased with
clockwise rotation and decreased with counterclockwise
rotation.
Figure 26
Figure 25
19
Mono
Press the MONO Mode Push-button to combine Left and
Right Stereo Signals to Mono, for the MAIN, OUTPUTs
1&2 and the HEADPHONES Jack. The MODE Push-button on the Remote Control also can be used to switch between the Stereo and Mono Modes of Operation.
Note: The TAPE/REC Outputs are not effected by the Mono
Mode of Operation.
Balance Control
Adjust the BALANCE Control as needed to achieve approximately equal listening volume levels in each Loudspeaker. Rotate the BALANCE Control clockwise to emphasize the Right Channel by reducing the volume level of
the Left Channel. Refer to figure 27.
Figure 27
Several seconds after the rotation of the BALANCE Control has stopped, the Front Panel Alphanumeric Display will
once again indicate the Input Source and Volume together
with the “>” symbol to show that the Right Channel is now
louder than the Left Channel. Refer to figure 28.
Setup
Pressing the SETUP Push-button activates the Setup Mode
of the C2200 and allows customizing various operating
functions. Refer to page 14 for additional information.
Output 1 and 2
Press OUTPUT 1 or 2 Push-buttons to send audio to separate Power Amplifiers connected to the rear panel OUTPUTS 1 or 2. It also activates the POWER CONTROL 1
&2 Sockets on the rear panel of the C2200. Press either
Push-button individually or both together.
Meter Lights
Rotate the METER LIGHTS Control counterclockwise to
switch Off the Meter Illumination and rotate the control
clockwise to switch On the Meter Illumination.
Note: It is normal for the brightness of the Front Panel
Alphanumeric Display to dim when the Meter
Illumination is switched Off. Refer to page 14 for
additional information.
Pass Thru Mode
When the C2200 is connected together with a McIntosh
Multichannel A/V Control Center or Surround Decoder and
has the PASS THRU MODE activated, it will automatically
Turn-On whenever the A/V Control Center or Surround Decoder is switched On. It will indicate on the Front Panel Alphanumeric Display “PASSTHRU”. Refer to figure 31.
Figure 28
Rotate the BALANCE Control counterclockwise to
deemphasize the Right Channel until equal Balance of both
Channels is achieved. Refer to figure 29.
Figure 29
Mute
Press the MUTE Push-button to Mute the Audio at the
MAIN, OUTPUTS 1 & 2 and HEADPHONES Outputs.
The Front Panel Alphanumeric Display will indicate the Input Source Name followed by the word MUTE in place of
the actual volume setting. Refer to figure 30.
Figure 30
20
Figure 31
In the PASS THRU Mode, the OUTPUTS 1&2 Pushbuttons remain active. The remaining C2200 Front Panel
Controls and Push-buttons are deactivated as long as the
C2200 is in the PASS THRU MODE.
Note: The C2200 Preamplifier remembers separately, the
setting of the OUTPUTS 1&2 Push-buttons when in the
Pass Thru Mode.
Reset of Microprocessors
In the event that the controls of the C2200 stop functioning,
push the POWER switch OFF and wait about two minutes.
Then push the POWER switch ON followed by pushing the
STANDBY/ON Push-button. This will reset the C2200 microprocessors and the Preamplifier should be functioning
normally.
Note: The above condition is usually caused by either
interruptions in AC power and/or major changes that
may occur in AC power line voltage.
How to Operate the C2200, con’t
Default Settings
To restore the C2200 to Factory Default Settings perform
the following. Press and hold in the MONO Push-button
together with the OUTPUTS 2 Push-button. Approximately
5 seconds after holding in the two the Front Panel Push-buttons together, the Front Panel Alphanumeric Display will
indicate MASTER RESET. Refer to figure 32.
Figure 32
Release both Push-buttons and the Front Panel Alphanumeric Display will now indicate -- CLEARED - - and the
C2200 will switch Off. Refer to figure 33.
Figure 33
Press the STANDBY/ON Push-button on the C2200 and
proceed to the Setup on page 14 to re-enter and custom setting that have beeen previously made.
Output Meters
The C2200’s Output Meters indicate the Output Voltage
available at the MAIN and OUTPUT 1 & 2 Jacks to drive
Power Amplifiers. Refer to figure 34. The Meters are calibrated in dBs (decibles) and respond to all the peaks contained in the musical information. They indicate to an accuracy of at least 95% of a single cycle from a 2000Hz tone
burst.
The Meter Electronic Circuitry “Time Stretches” the
Meter Drive Signal so the Meter Pointer pauses just long
enough for the human eye to see it and is followed by a
moderate decay rate.
Figure 34
21
Remote Control Push-Buttons
Turns AC Power ON or OFF to
certain McIntosh Components
when connected via the Data Port
Press to Power the C2200 ON
or OFF
Selects one of the eight
Audio Sources
Selects CD Player or
Tape Recorder Functions
and also performs various
functions on a variety of
McIntosh Components
Press the push-button
to illuminate the keys
Selects the REWind
Mode on Disc Players
and Tuning Down the
AM/FM Dial
Use to select tuner
presets, disc tracks or
any numbered operation
Selects Switched Output
1, AM Tuner Operating
Functions and Disc Selection on certain McIntosh CD Players
Mutes the audio
Selects Functions for
McIntosh Home Controller and as a “shift” key
when used with the AM
or FM Push-buttons to
select Output (Spkr) 1 or
2
Selects On Screen Functions for McIntosh DVD
Players and certain CD
Players
Selects the Fast Forward
Mode on Disc Players
and Tuning Up the AM/
FM Dial
Press to REVIEW Tuner
Station Presets and selects certain functions on
McIntosh CD Players
Press MODE to switch
between Stereo or Mono
Modes
Press TRIM and then the
LEVEL Push-buttons to
Trim the Input Sound
Level
Selects Switched Output
2, FM Tuner Operating
Functions and Track Selection on certain McIntosh CD Players
Adjusts the volume
level up or down
22
How to Operate by Remote Control
How to Operate by Remote Control
The supplied Remote Control is capable of directly controlling the functions of contemporary McIntosh Source Components connected to the C2200. Earlier McIntosh source
components and other brand source components can be controlled by the C2200 with the addition of a McIntosh Remote Control Translator (RCT).
Note: Your McIntosh Dealer can assist you with the
installation and operation of the Remote Control
Translator (RCT).
Mute
Press the MUTE Push-button to mute audio at the all the
Preamplifier Outputs, except the TAPE OUTPUTS. Press
MUTE a second time to unmute audio.
Mono
Press the MODE Push-button to combine Left and Right
Stereo Signals to Mono at all the Preamplifier Outputs, except the Tape Outputs.
Trim and Level
Press the TRIM Push-button to active the Input TRIM
Function. Press the LEVEL Up and Down Push-buttons to Trim the Input Sound Level. For additional information refer to page 15.
Input Source Selection
Press any of the eight Input Push-buttons to select a program source.
CD/Tape Functions
Use these push-buttons to operate a CD Player, CD
Changer or Tape Recorder.
Numbered Push-buttons
Press Push-buttons 0 through 9 to access tuner station presets or CD tracks/discs.
Disc and Track
Use the DISC and TRACK Push-buttons when a CD player
or changer is being used.
Volume
Press the Up or Down VOLUME Push-button to raise
or lower the listening volume level.
Note: The TAPE OUPUTS are not affected by volume
changes.
Amplifier Selection
Press HOME Push-button followed by the SPEAKER 1 or
2 Push-buttons either separately or together, to control the
Rear Panel OUTPUTS 1, 2 Jacks.
Acc On/Acc Off
Press ACC ON to turn the power ON to a McIntosh Disc
Player. Press ACC OFF to turn the power OFF to a McIntosh Disc Player.
E
Press E to perform various functions on a variety of McIntosh Components. It will also pause the playing of a Disc or
Tape Player.
Lighting
Press and release the LIGHTING Push-button to momentarily illuminate the upper half of the Remote Control Pushbuttons.
Note: While the LIGHTING Push-button is being depressed
the Remote Control will be unable to send a remote
command. When the LIGHTING Push-button is
released the push-buttons will continue to stay
illuminated for approximately three seconds thus
allowing you to send the desired command.
Optional Remote Control
If the C2200 is used in the Pass Thru Mode, an optional
McIntosh Remote Control Model UR12
allows use of an Alternate Set of Remote
Control Codes. This will prevent the
C2200 from responding to the McIntosh
A/V Control Center or Surround Decoder Remote Control. See your McIntosh Dealer for additional information.
Tuner Push-buttons
Press the AM or FM Push-button to select the desired
broadcast band. Press and release the Channel Up or
DownPush-button to move from station to station. Press
and hold a Channel Up or Down Push-button to move
continuously from station to station. Press REVIEW to start
the automatic brief audition of each of the presets stored in
the tuner memory. Press REVIEW a second time to stop on
a station preset and exit the Review process.
23
Technical Description
McIntosh Laboratory, the company who introduced the
world’s first amplifier that could be called “High Fidelity”,
has done it again. The McIntosh engineering staff has created a Tube Preamplifier without compromise, using the
most advanced McIntosh circuit design concepts. Creating a
Preamplifier with this level of performance did not come
easily. Many months of design, testing and measuring were
required. Extensive controlled listening tests, the ultimate
form of measuring, were made before the final design was
accepted.
Input and Output Switching
All signal switching in the C2200 is done by Electro-Magnetic devices. Electro-Magnetic Switching is a proven technology that uses the latest in materials and manufacturing
methods. Each switch consists of a glass tube that is filled
with an inert oxygen-free atmosphere and sealed with tiny
leads protruding from either end. These leads extend into the
tube and overlap one another with a separation of a few
thousandths of an inch. The leads are made from a ferrous
material that is influenced by a magnetic field. They are
first plated with gold as a base material, then with rhodium
and finally ruthenium. Ruthenium is the best contact material known.
The glass assembly is then placed in the center of a multilayer coil of copper wire. The entire assembly is molded
together in a tough shock absorbing material. The switch
and coil connectors extend from the bottom in the form of
printed circuit board terminals. When a DC voltage is applied to the coil, current flows and creates a magnetic field.
The force of the field causes the leads to bend and contact
one another inside the sealed glass tube. The inert gas eliminates corrosion of the contacts and insures a low resistance,
distortion free switch.
All inputs, outputs, and data ports are controlled by
logic circuits in the C2200. The logic is changed by Front
Panel Push-buttons or by a microprocessor IR decoder. This
microprocessor IR decoder is programmed with exclusive
McIntosh software. It receives data from the Front Panel or
Keypad/Sensors and provides the command signals for input switching, data switching, and volume control.
Phono Circuitry
The PHONO amplifier uses 12AX7 tubes. Its input stage
has been optimized for low noise and low distortion performance. Open loop gain of this circuit is 10,000. With high
open loop gain, a large amount of negative feedback can be
used around the phono amplifier to further reduce noise and
24
Top Inside View of the C2200
distortion. The feedback network also provides precision
RIAA frequency compensation.
Input sensitivity of the phono amplifier is 4.4 millivolts.
The gain of the amplifier is 40dB at 1000Hz. The phono
amplifier has a very wide dynamic range. At 1000Hz, the
phono input circuit will accept 50 millivolts without overload, a voltage far greater than the output of any current
magnetic phono cartridge. Therefore, phono input overload
is virtually impossible. A signal level of 10 millivolts at the
phono input at 1000Hz will produce 1 volt at the TAPE output. This output has a source impedance of 500 ohms unbalanced.
Tone Control Circuitry
The TONE control section uses 12AX7 amplifiers. The amplifier stages have been optimized for low noise and minimum distortion. Other electrical circuits are arranged in a
configuration that is the equivalent of a series turned circuit.
A control potentiometer inserts this series tuned circuit into
either the feedback or input section of the tone amplifier.
This provides a 12dB boost or cut at the frequency of the
tuned circuit. The overall gain of the stage is 0dB when the
potentiometer is at its center detent position. A TONE BYPASS Switch is provided to remove all tone control circuits
from the signal path.
Volume Control Circuitry
The VOLUME Control for the C2200 is a very special “Hi
Tech” circuit. It employs a Microprocessor Controlled
Technical Description
Logarithmic Attenuator. There are stringent requirements
for the Volume Attenuator in this design. The channel to
channel tracking accuracy must be maintained. After a great
deal of research we found that mechanical potentiometers
cannot approach the tracking accuracy that McIntosh felt
was necessary. Therefore, we choose to use a dual attenuator with switching driven from a 16-bit serial data word.
Resistor values are decoded by an internal multiplexer to
steps of 0.5dB. Total attenuator range is 107dB. Step error
and channel matching is less than .1dB. THD+N is typically
less than .001% and dynamic range is 120dB. A second
stage is added to the volume attenuator. It controls the gain
of the output amplifier. Its steps are interlaced with the main
section in such a manner that it reduces the output amplifier
gain to unity almost immediately as volume is reduced.
Therefore, noise and distortion generated in earlier stages is
not amplified and low level S/N is dramatically improved. It
is comparable to having a straight wire between the input
switching and output connector. Care has been taken to insure that there are no audible artifacts in the analog output
signal during volume control changes. There is a zero
Bottom Inside View of the C2200
crossing detector built in and all changes in level occur at
the signal zero crossing.
Overall Design
The C2200 was designed to use the best components available. All resistors are the lowest noise 1% metal film. Each
amplifier section has its own power supply filter. The
C2200 is truly worthy of being considered a companion and
peer of the world famous MC2000 and MC2102 Tube
Power Amplifiers.
Side Inside View of the C2200
Block Diagram
of
Preamplifier
and Meter
Circuitry
(one channel
shown)
with
Power Supply
25
Specifications
Specifications
Frequency Response
+0, -0.5dB from 20Hz to 20,000Hz
Total Harmonic Distortion
0.08% from 20Hz to 20,000Hz
Signal To Noise Ratio
Phono, 80dB
High Level, 93dB
Maximum Voltage Output
8Vrms Unbalanced, 16Vrms Balanced
Output Impedance
250 ohms Unbalanced, 500 ohms Balanced
Sensitivity
Phono MM, 4.4mV for 2.5V rated output
High Level, 450mV for 2.5V rated output
Input Impedance
Phono MM, 47K ohms, 65pF
High Level, 22K Unbalanced, 44K Balanced
Maximum Input Signal
Phono MM, 50mV @ 1,000Hz
High Level, 5V Unbalanced, 10V Balanced
Power Requirements
100 Volts, 50/60Hz at 75 watts
110 Volts, 50/60Hz at 75 watts
120 Volts, 50/60Hz at 75 watts
220 Volts, 50/60Hz at 75 watts
230 Volts, 50/60Hz at 75 watts
240 Volts, 50/60Hz at 75 watts
Note: Refer to the rear panel of the C2200 for the correct
voltage.
26
Tube Compliment
Phono Circuitry:
2 - 12AX7A
2 - 12AT7A
High Level Circuitry:
2 - 12AX7A
2 - 12AT7A
Overall Dimensions
17-1/2 inches (44.5cm) W, 7-5/8 inches (19.37cm) H, 20
inches (50.8cm) D (including clearance for connectors)
Weight
26.75 pounds (12.14 kg) net, 47.75 pounds (21.67 kg) in
shipping carton
Packing Instructions
Packing Instructions
In the event it is necessary to repack the equipment for shipment, the equipment must be packed exactly as shown below. It is very important that the four plastic feet are attached to the bottom of the equipment. This will ensure the
proper equipment location on the bottom pad. Failure to do
this will result in shipping damage.
Use the original shipping carton and interior parts only if
they are all in good serviceable condition. If a shipping carton or any of the interior part(s) are needed, please call or
write Customer Service Department of McIntosh Laboratory. Please see the Part List for the correct part numbers.
Quantity
1
4
Part Number
033888
033887
Description
Shipping carton only
End cap
1
1
1
1
033697
033725
034194
034037
Inside carton only
Top pad
Bottom pad
Inner carton pad
4
4
4
017218
100159
104083
Plastic foot
#10-32 x 3/4” screw
#10-7/16” Flat washer
27
McIntosh Laboratory, Inc.
2 Chambers Street
Binghamton, NY 13903
McIntosh Part No. 04080701