Download Datalogic GRYPHON Specifications
Transcript
Gryphon™ Family General Purpose Handheld Linear Imager or Laser Bar Code Readers Gryphon I GD4100/GM4100 Gryphon BT4100/ L GD4300 Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation. Should future revisions of this manual be published, you can acquire printed versions by contacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page. Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A and the E.U. All other brand and product names referred to herein may be trademarks of their respective owners. Microsoft Windows®, Windows® XP and the Windows logo are registered trademarks of Microsoft Corporation. Patents Gryphon I GD4100, I GD4100-HC This product may be covered by one or more of the following patents: Design Patents: CN ZL200830142386.5; CN ZL200930006852.1; EP870787; USD599799; USD606076. Utility Patents: CN ZL200680050007.8; EP0789315B1; EP0926620B1; EP0997760B1; EP1128314B1; EP1128315B1; EP1164536B1; EP1217571B1; EP1396811B1; EP1413971B1; EP1804089B1; EP1942442B1; US5481098; US5493108; US5992740; US6098883; US6260764; US6443360; US6454168; US6494376; US6517003; US6561427; US6808114; US6871785; US6997385; US7075663; US7387246; US7527198; US8006904; US8113430; USRE41349. Gryphon GM41XX, GBT41XX This product may be covered by one or more of the following patents: Design Patents: CN ZL200830142386.5; CN ZL200930006852.1; CN ZL201030175545.9; EP870787; EP1177943; USD599799; USD606076; USD629003. Utility Patents: CN ZL200680050007.8; EP0789315B1; EP0926620B1; EP0997760B1; EP1128314B1; EP1128315B1; EP1164536B1; EP1217571B1; EP1396811B1; EP1413971B1; EP1804089B1; EP1942442B1; US5481098; US5493108; US5992740; US6098883; US6260764; US6443360; US6454168; US6494376; US6517003; US6561427; US6808114; US6871785; US6997385; US7075663; US7387246; US8113430; USRE41349. BC40XX UV Counterfeit Detection, CFS4000, CHR-GM40 This product may be covered by one or more of the following patents: Design Patents: CN ZL201030175545.9; EP1177943; USD629003. Gryphon L GD4300 This product may be covered by one or more of the following patents: Design Patents: CN ZL200830142386.5; CN ZL200930006852.1; EP870787; USD599799; USD606076. Utility Patents: EP0789315B1; EP1128314B1; EP1128315B1; EP1396811B1; EP1413971B1; EP1942442B1; US5481098; US5493108; US5992740; US6454168; US6494376; US6517003; US6561427; US6808114; US6997385; US7387246 Additional patents pending. Table of Contents INTRODUCTION ................................................................................................................................................................................ 9 About this Manual .......................................................................................................................................................................................... 9 Overview .................................................................................................................................................................................................................................................... 9 Manual Conventions ...........................................................................................................................................................................................................................10 References ..................................................................................................................................................................................................... 10 Technical Support ........................................................................................................................................................................................ 10 Datalogic Website Support ...............................................................................................................................................................................................................10 Reseller Technical Support ................................................................................................................................................................................................................10 Telephone Technical Support ..........................................................................................................................................................................................................10 About the Reader ......................................................................................................................................................................................... 11 The BC40xx™ Radio Base ............................................................................................................................................................................. 11 Base LEDs .................................................................................................................................................................................................................................................11 Base Button .............................................................................................................................................................................................................................................12 BC40XX UV Counterfeit Detection .............................................................................................................................................................. 12 Display ........................................................................................................................................................................................................... 14 Battery Safety ............................................................................................................................................................................................... 14 Programming the Reader ............................................................................................................................................................................ 16 Configuration Methods ......................................................................................................................................................................................................................16 SETUP .............................................................................................................................................................................................. 17 Unpacking ..................................................................................................................................................................................................... 17 Setting Up the Reader .................................................................................................................................................................................. 17 Installing the Interface Cable ...................................................................................................................................................................... 18 Configuring the Base Station ...................................................................................................................................................................... 20 Changing the Base Station Position ..............................................................................................................................................................................................21 Connecting the Base Station ............................................................................................................................................................................................................22 Connecting the Base when Security Pin is Enabled .................................................................................................................................................................25 Linking the Reader to a Base Station .............................................................................................................................................................................................25 Linking a BT Reader to a PC ..............................................................................................................................................................................................................26 GRYPHON™ I System and Network Layouts ............................................................................................................................................... 27 Stand Alone Layouts ...........................................................................................................................................................................................................................27 Interface Selection ....................................................................................................................................................................................... 29 Setting the Interface ............................................................................................................................................................................................................................29 Customizing Configuration Settings .......................................................................................................................................................... 33 Configure Interface Settings ...........................................................................................................................................................................................................33 Global Interface Features ...................................................................................................................................................................................................................33 Configuring Other Features ..............................................................................................................................................................................................................33 Software Version Transmission .......................................................................................................................................................................................................33 Resetting the Product Configuration to Defaults .....................................................................................................................................................................34 Replacing the Battery ..........................................................................................................................................................................................................................35 CONFIGURATION USING BARCODES ............................................................................................................................................ 37 Configuration Parameters .................................................................................................................................................................................................................37 Reading Configuration Barcodes ....................................................................................................................................................................................................38 GLOBAL INTERFACE FEATURES 39 Host Commands — Obey/Ignore .............................................................................................................................................................................39 USB Suspend Mode ........................................................................................................................................................................................................39 RS-232 ONLY Interface ........................................................................................................................................................... 41 Baud Rate ...........................................................................................................................................................................................................................42 Data Bits .............................................................................................................................................................................................................................43 Stop Bits ..............................................................................................................................................................................................................................43 Parity ....................................................................................................................................................................................................................................44 Handshaking Control ....................................................................................................................................................................................................45 RS-232/USB-Com Interfaces................................................................................................................................................... 46 Intercharacter Delay .......................................................................................................................................................................................................47 Beep On ASCII BEL ..........................................................................................................................................................................................................47 Product Reference Guide 1 Contents Beep On Not on File .......................................................................................................................................................................................................48 ACK NAK Options ............................................................................................................................................................................................................49 ACK Character ..................................................................................................................................................................................................................50 NAK Character ..................................................................................................................................................................................................................50 ACK NAK Timeout Value ...............................................................................................................................................................................................51 ACK NAK Retry Count ....................................................................................................................................................................................................51 ACK NAK Error Handling ...............................................................................................................................................................................................52 Indicate Transmission Failure .....................................................................................................................................................................................52 Disable Character ............................................................................................................................................................................................................53 Enable Character .............................................................................................................................................................................................................53 Keyboard Interface................................................................................................................................................................. 55 Country Mode ..................................................................................................................................................................................................................56 Caps Lock State ................................................................................................................................................................................................................59 Numlock .............................................................................................................................................................................................................................60 Send Control Characters ..............................................................................................................................................................................................61 Wedge Quiet Interval ....................................................................................................................................................................................................62 Intercharacter Delay .......................................................................................................................................................................................................63 Intercode Delay ...............................................................................................................................................................................................................64 USB Keyboard Speed .....................................................................................................................................................................................................65 USB Keyboard Numeric Keypad ................................................................................................................................................................................66 USB-OEM Interface ................................................................................................................................................................. 67 USB-OEM Device Usage ................................................................................................................................................................................................68 Interface Options ............................................................................................................................................................................................................68 IBM 46XX Interface ................................................................................................................................................................. 69 46xx Number of Host Resets .......................................................................................................................................................................................70 Transmit Labels in Code 39 Format ..........................................................................................................................................................................72 Interface Options ............................................................................................................................................................................................................72 Wand Emulation Interface ..................................................................................................................................................... 73 Wand Signal Speed ........................................................................................................................................................................................................74 Wand Polarity ...................................................................................................................................................................................................................74 Wand Idle State ................................................................................................................................................................................................................75 Transmit Noise .................................................................................................................................................................................................................75 Label Symbology Conversion .....................................................................................................................................................................................76 Data Format ............................................................................................................................................................................ 77 Global Prefix/Suffix .........................................................................................................................................................................................................78 Global AIM ID ....................................................................................................................................................................................................................79 GS1-128 AIM ID ................................................................................................................................................................................................................80 Label ID ...............................................................................................................................................................................................................................81 Label ID: Pre-loaded Sets .............................................................................................................................................................................................81 Label ID: Set Individually Per Symbology ...............................................................................................................................................................81 Label ID Control ...............................................................................................................................................................................................................82 Label ID Symbology Selection ...................................................................................................................................................................................83 Set Global Mid Label ID Characters ..........................................................................................................................................................................89 Case Conversion ..............................................................................................................................................................................................................90 Character Conversion ....................................................................................................................................................................................................90 Reading Parameters .............................................................................................................................................................. 91 Double Read Timeout ...................................................................................................................................................................................................92 Label Gone Timeout ......................................................................................................................................................................................................93 Sleep Mode Timeout .....................................................................................................................................................................................................94 LED AND BEEPER INDICATORS ................................................................................................................................................... 96 Power On Alert .................................................................................................................................................................................................................96 Good Read: When to Indicate .....................................................................................................................................................................................96 Good Read Beep Type ...................................................................................................................................................................................................97 Good Read Beep Frequency .......................................................................................................................................................................................97 Good Read Beep Length ..............................................................................................................................................................................................98 Good Read Beep Volume .............................................................................................................................................................................................99 Good Read LED Duration .......................................................................................................................................................................................... 100 SCANNING FEATURES ...............................................................................................................................................................101 Scan Mode ...................................................................................................................................................................................................................... 101 Stand Mode Triggered Timeout ............................................................................................................................................................................. 102 Stand Detection ............................................................................................................................................................................................................ 103 2 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Contents Stand Mode Sensitivity .............................................................................................................................................................................................. 104 Scanning Active Time ................................................................................................................................................................................................. 104 Flash On Time ................................................................................................................................................................................................................ 105 Flash Off Time ................................................................................................................................................................................................................ 105 Green Spot Duration ................................................................................................................................................................................................... 106 Code Selection ...................................................................................................................................................................... 107 DISABLE ALL SYMBOLOGIES ....................................................................................................................................................108 CODE EAN/UPC ..........................................................................................................................................................................109 Coupon Control ............................................................................................................................................................................................................ 109 UPC-A ............................................................................................................................................................................................................................... 110 UPC-A Enable/Disable ................................................................................................................................................................................................ 110 UPC-A Check Character Transmission .................................................................................................................................................................. 110 Expand UPC-A to EAN-13 .......................................................................................................................................................................................... 111 UPC-A Number System Character Transmission .............................................................................................................................................. 111 UPC-A Minimum Reads .............................................................................................................................................................................................. 112 UPC-E ..........................................................................................................................................................................................113 UPC-E Enable/Disable ................................................................................................................................................................................................. 113 UPC-E Check Character Transmission ................................................................................................................................................................... 113 Expand UPC-E to EAN-13 .......................................................................................................................................................................................... 114 Expand UPC-E to UPC-A ............................................................................................................................................................................................ 114 UPC-E Number System Character Transmission ............................................................................................................................................... 115 UPC-E Minimum Reads .............................................................................................................................................................................................. 115 GTIN FORMATTING ....................................................................................................................................................................116 EAN 13 (JAN 13) .........................................................................................................................................................................117 EAN 13 Enable/Disable .............................................................................................................................................................................................. 117 EAN 13 Check Character Transmission ................................................................................................................................................................ 117 EAN-13 Flag 1 Character ............................................................................................................................................................................................ 118 EAN-13 ISBN Conversion ........................................................................................................................................................................................... 118 EAN 13 Minimum Reads ............................................................................................................................................................................................ 119 ISSN ............................................................................................................................................................................................120 ISSN Enable/Disable .................................................................................................................................................................................................... 120 EAN 8 (JAN 8) .............................................................................................................................................................................121 EAN 8 Enable/Disable ................................................................................................................................................................................................. 121 EAN 8 Check Character Transmission ................................................................................................................................................................... 121 Expand EAN 8 to EAN 13 ........................................................................................................................................................................................... 122 EAN 8 Minimum Reads ............................................................................................................................................................................................... 122 UPC/EAN GLOBAL SETTINGS ....................................................................................................................................................123 UPC/EAN Decoding Level ......................................................................................................................................................................................... 123 UPC/EAN Correlation .................................................................................................................................................................................................. 124 UPC/EAN Price Weight Check .................................................................................................................................................................................. 124 In-Store Minimum Reads ........................................................................................................................................................................................... 125 ADD-ONS ....................................................................................................................................................................................126 Optional Add-ons ........................................................................................................................................................................................................ 126 Optional Add-On Timer ............................................................................................................................................................................................. 127 Optional GS1-128 Add-On Timer ........................................................................................................................................................................... 130 P2 Add-Ons Minimum Reads ................................................................................................................................................................................... 133 P5 Add-Ons Minimum Reads ................................................................................................................................................................................... 134 GS1-128 Add-Ons Minimum Reads ....................................................................................................................................................................... 135 CODE 39 ......................................................................................................................................................................................136 Code 39 Enable/Disable ............................................................................................................................................................................................ 136 Code 39 Check Character Calculation .................................................................................................................................................................. 136 Code 39 Check Character Transmission .............................................................................................................................................................. 137 Code 39 Start/Stop Character Transmission ...................................................................................................................................................... 138 Code 39 Full ASCII ........................................................................................................................................................................................................ 138 Code 39 Quiet Zones .................................................................................................................................................................................................. 139 Code 39 Minimum Reads .......................................................................................................................................................................................... 140 Code 39 Decoding Level ........................................................................................................................................................................................... 141 Code 39 Length Control ............................................................................................................................................................................................ 142 Code 39 Set Length 1 ................................................................................................................................................................................................. 143 Code 39 Set Length 2 ................................................................................................................................................................................................. 144 Code 39 Interdigit Ratio ............................................................................................................................................................................................. 145 Code 39 Character Correlation ................................................................................................................................................................................ 147 Product Reference Guide 3 Contents Code 39 Stitching ......................................................................................................................................................................................................... 147 CODE 32 (ITAL PHARMACEUTICAL CODE) ...............................................................................................................................148 Code 32 Enable/Disable ............................................................................................................................................................................................ 148 Code 32 Feature Setting Exceptions ..................................................................................................................................................................... 148 Code 32 Check Char Transmission ........................................................................................................................................................................ 149 Code 32 Start/Stop Character Transmission ...................................................................................................................................................... 149 CODE 39 CIP (FRENCH PHARMACEUTICAL) .............................................................................................................................150 Code 39 CIP Enable/Disable ..................................................................................................................................................................................... 150 CODE 128 ...................................................................................................................................................................................151 Code 128 Enable/Disable .......................................................................................................................................................................................... 151 Expand Code 128 to Code 39 .................................................................................................................................................................................. 151 Code 128 Check Character Transmission ............................................................................................................................................................ 152 Code 128 Function Character Transmission ...................................................................................................................................................... 152 Code 128 Sub-Code Change Transmission ........................................................................................................................................................ 153 Code 128 Quiet Zones ................................................................................................................................................................................................ 154 Code 128 Minimum Reads ........................................................................................................................................................................................ 155 Code 128 Decoding Level ......................................................................................................................................................................................... 156 Code 128 Length Control .......................................................................................................................................................................................... 157 Code 128 Set Length 1 ............................................................................................................................................................................................... 158 Code 128 Set Length 2 ............................................................................................................................................................................................... 159 Code 128 Character Correlation ............................................................................................................................................................................. 160 Code 128 Stitching ...................................................................................................................................................................................................... 160 GS1-128 ......................................................................................................................................................................................161 GS1-128 Enable ............................................................................................................................................................................................................. 161 CODE ISBT 128 ...........................................................................................................................................................................162 ISBT 128 Concatenation ............................................................................................................................................................................................ 162 ISBT 128 Force Concatenation ................................................................................................................................................................................ 162 ISBT 128 Concatenation Mode ................................................................................................................................................................................ 163 ISBT 128 Dynamic Concatenation Timeout ........................................................................................................................................................ 164 ISBT 128 Advanced Concatenation Options ...................................................................................................................................................... 164 CODABLOCK F ............................................................................................................................................................................165 Codablock F Enable/Disable .................................................................................................................................................................................... 165 Codablock F EAN Enable/Disable ........................................................................................................................................................................... 165 Codablock F AIM Check ............................................................................................................................................................................................. 166 Codablock F Length Control .................................................................................................................................................................................... 166 Codablock F Set Length 1 ......................................................................................................................................................................................... 167 Codablock F Set Length 2 ......................................................................................................................................................................................... 168 INTERLEAVED 2 OF 5 (I 2 OF 5) .................................................................................................................................................169 I 2 of 5 Enable/Disable ................................................................................................................................................................................................ 169 I 2 of 5 Check Character Calculation ..................................................................................................................................................................... 169 I 2 of 5 Check Character Transmission .................................................................................................................................................................. 170 I 2 of 5 Minimum Reads ............................................................................................................................................................................................. 171 2 of 5 Decoding Level ................................................................................................................................................................................................. 172 I 2 of 5 Length Control ............................................................................................................................................................................................... 173 I 2 of 5 Set Length 1 ..................................................................................................................................................................................................... 174 I 2 of 5 Set Length 2 ..................................................................................................................................................................................................... 175 I 2 of 5 Character Correlation ................................................................................................................................................................................... 176 I 2 of 5 Stitching ............................................................................................................................................................................................................ 176 FOLLETT 2 OF 5 ..........................................................................................................................................................................177 Follett 2 of 5 Enable/Disable .................................................................................................................................................................................... 177 INTERLEAVED 2 OF 5 CIP HR .....................................................................................................................................................177 Interleaved 2 of 5 CIP HR Enable/Disable ............................................................................................................................................................ 177 STANDARD 2 OF 5 .....................................................................................................................................................................178 Standard 2 of 5 Enable/Disable .............................................................................................................................................................................. 178 Standard 2 of 5 Check Character Calculation .................................................................................................................................................... 178 Standard 2 of 5 Check Character Transmission ................................................................................................................................................. 179 Standard 2 of 5 Minimum Reads ............................................................................................................................................................................ 179 Standard 2 of 5 Decoding Level ............................................................................................................................................................................. 180 Standard 2 of 5 Length Control .............................................................................................................................................................................. 180 Standard 2 of 5 Set Length 1 ................................................................................................................................................................................... 181 Standard 2 of 5 Set Length 2 ................................................................................................................................................................................... 182 Standard 2 of 5 Character Correlation .................................................................................................................................................................. 183 4 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Contents Standard 2 of 5 Stitching ........................................................................................................................................................................................... 183 INDUSTRIAL 2 OF 5 ....................................................................................................................................................................184 Industrial 2 of 5 Enable/Disable .............................................................................................................................................................................. 184 Industrial 2 of 5 Check Character Calculation .................................................................................................................................................... 184 Industrial 2 of 5 Check Character Transmission ................................................................................................................................................ 185 Industrial 2 of 5 Length Control .............................................................................................................................................................................. 185 Industrial 2 of 5 Set Length 1 ................................................................................................................................................................................... 186 Industrial 2 of 5 Set Length 2 ................................................................................................................................................................................... 187 Industrial 2 of 5 Minimum Reads ............................................................................................................................................................................ 188 Industrial 2 of 5 Stitching .......................................................................................................................................................................................... 188 Industrial 2 of 5 Character Correlation ................................................................................................................................................................. 189 CODE IATA ..................................................................................................................................................................................190 IATA Enable/Disable ................................................................................................................................................................................................... 190 IATA Check Character Transmission ..................................................................................................................................................................... 190 DATALOGIC 2 OF 5 ....................................................................................................................................................................191 Datalogic 2 of 5 Enable/Disable .............................................................................................................................................................................. 191 Datalogic 2 of 5 Check Character Calculation ................................................................................................................................................... 191 Datalogic 2 of 5 Minimum Reads ........................................................................................................................................................................... 192 Datalogic 2 of 5 Decoding Level ............................................................................................................................................................................. 192 Datalogic 2 of 5 Length Control ............................................................................................................................................................................. 193 Datalogic 2 of 5 Set Length 1 ................................................................................................................................................................................... 194 Datalogic 2 of 5 Set Length 2 ................................................................................................................................................................................... 195 Datalogic 2 of 5 Character Correlation ................................................................................................................................................................. 196 Datalogic 2 of 5 Stitching .......................................................................................................................................................................................... 196 CODABAR ...................................................................................................................................................................................197 Codabar Enable/Disable ............................................................................................................................................................................................ 197 Codabar Check Character Calculation .................................................................................................................................................................. 197 Codabar Check Character Transmission .............................................................................................................................................................. 198 Codabar Start/Stop Character Transmission ...................................................................................................................................................... 198 Codabar Start/Stop Character Set .......................................................................................................................................................................... 199 Codabar Start/Stop Character Match ................................................................................................................................................................... 199 Codabar Quiet Zones .................................................................................................................................................................................................. 200 Codabar Minimum Reads ......................................................................................................................................................................................... 201 Codabar Decoding Level ........................................................................................................................................................................................... 202 Codabar Length Control ............................................................................................................................................................................................ 203 Codabar Set Length 1 ................................................................................................................................................................................................. 204 Codabar Set Length 2 ................................................................................................................................................................................................. 205 Codabar Interdigit Ratio ............................................................................................................................................................................................ 206 Codabar Character Correlation ............................................................................................................................................................................... 208 Codabar Stitching ........................................................................................................................................................................................................ 208 ABC CODABAR ...........................................................................................................................................................................209 ABC Codabar Enable/Disable .................................................................................................................................................................................. 209 ABC Codabar Concatenation Mode ...................................................................................................................................................................... 209 ABC Codabar Dynamic Concatenation Timeout .............................................................................................................................................. 210 ABC Codabar Force Concatenation ....................................................................................................................................................................... 211 CODE 11 ......................................................................................................................................................................................212 Code 11 Enable/Disable ............................................................................................................................................................................................ 212 Code 11 Check Character Calculation .................................................................................................................................................................. 212 Code 11 Check Character Transmission .............................................................................................................................................................. 213 Code 11 Minimum Reads .......................................................................................................................................................................................... 213 Code 11 Length Control ............................................................................................................................................................................................ 214 Code 11 Set Length 1 ................................................................................................................................................................................................. 215 Code 11 Set Length 2 ................................................................................................................................................................................................. 216 Code 11 Interdigit Ratio ............................................................................................................................................................................................. 217 Code 11 Decoding Level ........................................................................................................................................................................................... 219 Code 11 Character Correlation ................................................................................................................................................................................ 220 Code 11 Stitching ......................................................................................................................................................................................................... 220 GS1 DATABAR™ OMNIDIRECTIONAL .......................................................................................................................................221 GS1 DataBar™ Omnidirectional Enable/Disable ............................................................................................................................................... 221 GS1 DataBar™ Omnidirectional GS1-128 Emulation ....................................................................................................................................... 221 GS1 DataBar™ Omnidirectional Minimum Reads ............................................................................................................................................. 222 GS1 DATABAR™ EXPANDED .....................................................................................................................................................223 Product Reference Guide 5 Contents GS1 DataBar™ Expanded Enable/Disable ............................................................................................................................................................ 223 GS1 DataBar™ Expanded GS1-128 Emulation ................................................................................................................................................... 223 GS1 DataBar™ Expanded Minimum Reads ......................................................................................................................................................... 224 GS1 DataBar™ Expanded Length Control ........................................................................................................................................................... 224 GS1 DataBar™ Expanded Set Length 1 ................................................................................................................................................................. 225 GS1 DataBar™ Expanded Set Length 2 ................................................................................................................................................................. 226 GS1 DATABAR™ LIMITED ..........................................................................................................................................................227 GS1 DataBar™ Limited Enable/Disable ................................................................................................................................................................. 227 GS1 DataBar™ Limited GS1-128 Emulation ........................................................................................................................................................ 227 GS1 DataBar™ Limited Minimum Reads .............................................................................................................................................................. 228 CODE 93 ......................................................................................................................................................................................229 Code 93 Enable/Disable ............................................................................................................................................................................................ 229 Code 93 Check Character Calculation .................................................................................................................................................................. 229 Code 93 Check Character Transmission .............................................................................................................................................................. 230 Code 93 Length Control ............................................................................................................................................................................................ 230 Code 93 Set Length 1 ................................................................................................................................................................................................. 231 Code 93 Set Length 2 ................................................................................................................................................................................................. 232 Code 93 Minimum Reads .......................................................................................................................................................................................... 233 Code 93 Decoding Level ........................................................................................................................................................................................... 234 Code 93 Quiet Zones .................................................................................................................................................................................................. 235 Code 93 Stitching ......................................................................................................................................................................................................... 236 Code 93 Character Correlation ................................................................................................................................................................................ 236 MSI ..............................................................................................................................................................................................237 MSI Enable/Disable ...................................................................................................................................................................................................... 237 MSI Check Character Calculation ........................................................................................................................................................................... 237 MSI Check Character Transmission ........................................................................................................................................................................ 238 MSI Length Control ..................................................................................................................................................................................................... 238 MSI Set Length 1 .......................................................................................................................................................................................................... 239 MSI Set Length 2 .......................................................................................................................................................................................................... 240 MSI Minimum Reads ................................................................................................................................................................................................... 241 MSI Decoding Level .................................................................................................................................................................................................... 242 PLESSEY ......................................................................................................................................................................................243 Plessey Enable/Disable .............................................................................................................................................................................................. 243 Plessey Check Character Calculation .................................................................................................................................................................... 244 Plessey Check Character Transmission ................................................................................................................................................................ 244 Plessey Length Control .............................................................................................................................................................................................. 245 Plessey Set Length 1 ................................................................................................................................................................................................... 246 Plessey Set Length 2 ................................................................................................................................................................................................... 247 Plessey Minimum Reads ............................................................................................................................................................................................ 248 Plessey Decoding Level ............................................................................................................................................................................................. 249 Plessey Stitching .......................................................................................................................................................................................................... 250 Plessey Character Correlation ................................................................................................................................................................................. 250 CODE 4 ........................................................................................................................................................................................251 Code 4 Enable/Disable ............................................................................................................................................................................................... 251 Code 4 Check Character Transmission ................................................................................................................................................................. 251 Code 4 Hex to Decimal Conversion ....................................................................................................................................................................... 252 CODE 5 ........................................................................................................................................................................................252 Code 5 Enable/Disable ............................................................................................................................................................................................... 252 Code 5 Check Character Transmission ................................................................................................................................................................. 253 Code 5 Hex to Decimal Conversion ....................................................................................................................................................................... 253 CODE 4 AND CODE 5 COMMON CONFIGURATION ITEMS ......................................................................................................254 Code 4 and 5 Decoding Level .................................................................................................................................................................................. 254 Code 4 and Code 5 Minimum Reads ..................................................................................................................................................................... 255 WIRELESS FEATURES................................................................................................................................................................... 257 WIRELESS BEEPER FEATURES ...................................................................................................................................................259 Good Transmission Beep .......................................................................................................................................................................................... 259 Beep Frequency ............................................................................................................................................................................................................ 259 Beep Duration ............................................................................................................................................................................................................... 260 Beep Volume ................................................................................................................................................................................................................. 261 Disconnect Beep .......................................................................................................................................................................................................... 261 Base Station Beep ........................................................................................................................................................................................................ 262 6 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Contents Leash Alarm .................................................................................................................................................................................................................... 262 CONFIGURATION UPDATES ......................................................................................................................................................264 Automatic Configuration Update .......................................................................................................................................................................... 264 Copy Configuration to Scanner .............................................................................................................................................................................. 264 Copy Configuration to Base Station ...................................................................................................................................................................... 265 Automatic Flash Update ............................................................................................................................................................................................ 265 Request Flash Update ................................................................................................................................................................................................ 266 Powerdown Timeout .................................................................................................................................................................................................. 266 BATCH FEATURES ......................................................................................................................................................................268 Batch Mode .................................................................................................................................................................................................................... 268 Send Batch ...................................................................................................................................................................................................................... 268 Erase Batch Memory ................................................................................................................................................................................................... 269 RF Batch Mode Transmit Delay ............................................................................................................................................................................... 269 DIRECT RADIO AUTOLINK .........................................................................................................................................................270 RF ADDRESS STAMPING ............................................................................................................................................................270 Source Radio Address Transmission ..................................................................................................................................................................... 270 Source Radio Address Delimiter Character ........................................................................................................................................................ 271 Features for Star Models Only ............................................................................................................................................. 272 STAR Radio Protocol Timeout ................................................................................................................................................................................. 272 STAR Radio Transmit Mode ...................................................................................................................................................................................... 273 DISPLAY FEATURES ...................................................................................................................................................................274 Contrast ........................................................................................................................................................................................................................... 274 Font Size .......................................................................................................................................................................................................................... 274 Backlight .......................................................................................................................................................................................................................... 275 Display Mode ................................................................................................................................................................................................................. 275 Display Timeout ............................................................................................................................................................................................................ 276 Keypad Select ................................................................................................................................................................................................................ 278 Bluetooth-Only Features...................................................................................................................................................... 279 BT SECURITY FEATURES ............................................................................................................................................................280 BT Security Mode ......................................................................................................................................................................................................... 280 BT Pin Code .................................................................................................................................................................................................................... 281 Select PIN Code Length ............................................................................................................................................................................................. 281 Set PIN Code .................................................................................................................................................................................................................. 281 BT HID FEATURES ......................................................................................................................................................................282 BT HID Variable PIN Code .......................................................................................................................................................................................... 282 BT HID ALT Mode ......................................................................................................................................................................................................... 282 BT HID Send Unkown ASCII Char ............................................................................................................................................................................ 283 OTHER BT FEATURES .................................................................................................................................................................284 BT Poll Rate ..................................................................................................................................................................................................................... 284 LASER FEATURES ......................................................................................................................................................................... 287 Laser Scan Angle .......................................................................................................................................................................................................... 288 Laser Idle Mode ............................................................................................................................................................................................................. 288 Bi-Directional Read Decoding ................................................................................................................................................................................. 289 Always On Scan Mode Timeout .............................................................................................................................................................................. 290 REFERENCES................................................................................................................................................................................. 291 RS-232 Parameters .....................................................................................................................................................................................291 RS-232 Only ......................................................................................................................................................................................................................................... 291 RS-232/USB COM Parameters ....................................................................................................................................................................................................... 292 Keyboard Interface .....................................................................................................................................................................................299 Wedge Quiet Interval ....................................................................................................................................................................................................................... 299 Intercharacter Delay ......................................................................................................................................................................................................................... 300 Intercode Delay .................................................................................................................................................................................................................................. 301 Symbologies ...............................................................................................................................................................................................302 Decoding Level .................................................................................................................................................................................................................................. 302 Set Length ............................................................................................................................................................................................................................................ 302 Data Editing ................................................................................................................................................................................................304 Global Prefix/Suffix ........................................................................................................................................................................................................................... 305 Global AIM ID ...................................................................................................................................................................................................................................... 306 Label ID ................................................................................................................................................................................................................................................. 307 Character Conversion ...................................................................................................................................................................................................................... 311 Reading Parameters ...................................................................................................................................................................................312 Product Reference Guide 7 Contents Label Gone Timeout ......................................................................................................................................................................................................................... 312 Good Read LED Duration ................................................................................................................................................................................................................ 313 Scanning Features ......................................................................................................................................................................................314 Scan Mode ........................................................................................................................................................................................................................................... 314 Scanning Active Time ...................................................................................................................................................................................................................... 315 Flash On Time ..................................................................................................................................................................................................................................... 316 Flash Off Time ..................................................................................................................................................................................................................................... 317 Display Settings ..........................................................................................................................................................................................318 Display Mode ...................................................................................................................................................................................................................................... 318 RF Features .................................................................................................................................................................................................318 Configuration Update ...................................................................................................................................................................................................................... 318 RF Address Stamping ....................................................................................................................................................................................................................... 318 BT-Only Features ............................................................................................................................................................................................................................... 321 MESSAGE FORMATTING.............................................................................................................................................................. 323 Message Formatting ..................................................................................................................................................................................323 Cursor Control .................................................................................................................................................................................................................................... 324 Font Selection ..................................................................................................................................................................................................................................... 324 Clearing Display ................................................................................................................................................................................................................................. 325 LED and Beeper Control .................................................................................................................................................................................................................. 325 Messages from Scanner Command Keys ..................................................................................................................................................326 Technical Specifications ............................................................................................................................................................. 327 Standard Cable Pinouts .............................................................................................................................................................................330 LED and Beeper Indications .......................................................................................................................................................................331 Error Codes ..................................................................................................................................................................................................332 Base Station Indications (Cordless Models ONLY) ...................................................................................................................................333 Base Station Button Indicators ..................................................................................................................................................................................................... 333 Standard Defaults ....................................................................................................................................................................... 335 Sample Bar Codes........................................................................................................................................................................ 347 Keypad ......................................................................................................................................................................................... 351 Scancode Tables .......................................................................................................................................................................... 355 Control Character Emulation .....................................................................................................................................................................355 Single Press and Release Keys ....................................................................................................................................................................................................... 355 Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE ...............................................................................................356 Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode ...........................................................................................................358 Digital Interface ..........................................................................................................................................................................................360 IBM31xx 102-key ........................................................................................................................................................................................361 IBM XT ..........................................................................................................................................................................................................362 Microsoft Windows Codepage 1252 .........................................................................................................................................................363 Index ......................................................................................................................................................................... 365 8 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Chapter 1 Introduction About this Manual This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. The Quick Reference Guide (QRG) and other publications associated with this product are downloadable free of charge from the website listed on the back cover of this manual. Overview Chapter 1, (this chapter) presents information about manual conventions, and an overview of the reader, its features and operation. Chapter 2, Setup presents information about unpacking, cable connection information and setting up the reader. Chapter 3, Configuration Using Barcodes provides instructions and barcode labels for customizing your reader. There are different sections for interface types, general features, data formatting, symbology-specific and model-specific features. Chapter 4, Wireless Features describes options and programming related to radio communication features for the RF variants of the Gryphon family. Chapter 5, Laser Features describes options and programming specific to laser models. Chapter 6, References provides background information and detailed instructions for more complex programming items. Chapter 7, Message Formatting provides details for programming options. Appendix A, Technical Specifications lists physical and performance characteristics, as well as environmental and regulatory specifications. It also provides standard cable pin-outs and LED/ Beeper functions. Appendix B, Standard Defaults references common factory default settings for reader features and options. Appendix C, Sample Bar Codes offers sample barcodes of several common symbologies. Appendix D, Keypad includes numeric barcodes to be scanned for certain parameter settings. Appendix E, Scancode Tables lists control character emulation information for Wedge and USB Keyboard interfaces. Product Reference Guide 9 Introduction Manual Conventions The following conventions are used in this document: The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the reader: Notes contain information necessary for properly diagnosing, repairing and operating the reader. The CAUTION symbol advises you of actions that could damage equipment or property. CAUTION References Current versions of this Product Reference Guide (PRG), Quick Reference Guide (QRG), the Datalogic Aladdin™ Configuration application, and any other manuals, instruction sheets and utilities for this product can be downloaded from the website listed below. Alternatively, printed copies or product support CDs for most products can be purchased through your Datalogic reseller. Technical Support Datalogic Website Support The Datalogic website (www.datalogic.com) is the complete source for technical support and information for Datalogic products. The site offers product support, warranty information, product manuals, product tech notes, software updates, demos, and instructions for returning products for repair. Reseller Technical Support An excellent source for technical assistance and information is an authorized Datalogic reseller. A reseller is acquainted with specific types of businesses, application software, and computer systems and can provide individualized assistance. Telephone Technical Support If you do not have internet or email access, you may contact Datalogic technical support at (541) 349-8283 or check the back cover of your manual for more contact information. 10 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 About the Reader About the Reader Typically, units are factory-programmed for the most common terminal and communications settings. If you need to modify any programmable settings, custom configuration can be accomplished by scanning the programming barcodes within this guide. Several models of the Gryphon are available, and are covered in this manual: • Gryphon I GD4100 - Corded linear imager barcode reader • Gryphon I GM4100 - Cordless linear imager barcode reader with Datalogic STAR™. • Gryphon L GD4300 - Model with Laser scan engine. • Gryphon I BT 4100 - Model with Bluetooth options. Programming can alternatively be performed using the Datalogic Aladdin™ Configuration application which is downloadable from the Datalogic website listed on the back cover of this manual. This multi-platform utility program allows device configuration using a PC. It communicates to the device using a serial or USB cable and can also create configuration barcodes to print. Advancements in the LED technology used in the imager-based readers significantly improve the illumination of the target field of view, resulting in higher scan efficiency. Whether used in Single Trigger or Continuous Mode, the ergonomic design of the reader will help to promote comfortable handling during extended periods of use. See "Interface Selection"on page 29 for a listing and descriptions of available interface sets by model type. The BC40xx™ Radio Base Base LEDs LEDs on the Gryphon I Base provide information about the Base’s status, as shown in Figure 1. Figure 1. Gryphon I Base LEDs YELLOW LED BUTTON RED LED / GREEN LED Product Reference Guide 11 Introduction The following table describes the significance of each LED: LED STATUS Yellow On = Base is powered Power on / Data Yellow Blinking = Base receives data and commands from the Host or the Reader. Charging Red On = Battery charging is in progress. Charge completed Green On = the Battery is completely charged. Charging + Charge completed Red and Green Blinking together = the Reader is not correctly placed onto the Base. See Base Station Indications (Cordless Models ONLY) on page 333 for more specific details on the LEDs. Base Button The Base contains a button which is used primarily to perform a paging function. Pressing the button causes a sound signal to be emitted by all scanners linked with this Base, as long as the scanner is awake (see Powerdown Timeout on page 266) and reception is enabled (see Sleep Mode Timeout on page 94). The button can also be used to "force device connection" via the Datalogic Aladdin Software tool (available for free download from the Datalogic website). See the Aladdin Online Help for details. See Base Station Indications (Cordless Models ONLY) on page 333 for further information on Base Button functions. BC40XX UV Counterfeit Detection The BC40XX Radio Base is available with a UV Counterfeit Money Detector, typically used to verify the authenticity of bank notes. Other uses for counterfeit detection are passport, ticket, credit card, travelers’ check and similar applications where it is possible to detect fluorescent marks with UV light. The detector contains eight special UV LEDs, as shown below: UV LEDs 12 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 BC40XX UV Counterfeit Detection The Counterfeit Detector is based on UV fluorescent emission. Real banknotes under ultraviolet rays usually absorb the UV light and will show special marks made with fluorescent inks. On the other hand, most counterfeit banknotes only reflect the UV lights, without showing fluorescent marks. To use: 1. Quickly press the Base button to light the UV LEDs. 2. Hold the item to be verified under the LED lights to ensure that the special fluorescent marks are visible. 3. The LEDs are set to switch off automatically after about 2 minutes. To keep the UV LEDs in always-on mode, quickly press the Base button a second time within 10 seconds of the first press. To switch them off, simply press the button again. An external power supply is necessary for full functionality of the Base station with UV Counterfeit Detector. Use only the recommended AC adapter 12Vdc. Product Reference Guide 13 Introduction Display The Gryphon GM4100 is available with an optional Display. The Display features 4 lines and 16 characters, and offers icons and three additional keys to allow a better interaction with a remote host. Fonts, contrast, backlight and other parameters can be configured for the Display. See Display Features on page 274 and Message Formatting on page 323 for more information. Figure 2. Gryphon™ I Display Battery Safety To reinstall, charge and/or perform any other action on the battery, follow the instructions in this manual. Before installing the Battery, read “Battery Safety” on this and the following pages. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum performance. WARNING 14 Do not discharge the battery using any device except for the scanner. When the battery is used in devices other than the designated product, it may damage the battery or reduce its life expectancy. If the device causes an abnormal current to flow, it may cause the battery to become hot, explode or ignite and cause serious injury. Lithium-ion battery packs may get hot, explode or ignite and cause serious injury if exposed to abusive conditions. Be sure to follow the safety warnings listed below: • Do not place the battery pack in fire or heat. • Do not connect the positive terminal and negative terminal of the battery pack to each other with any metal object (such as wire). • Do not carry or store the battery pack together with metal objects. • Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts or shocks. • Do not solder directly onto the battery pack. • Do not expose the battery pack to liquids, or allow the battery to get wet. • Do not apply voltages to the battery pack contacts. Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Battery Safety WARNING In the event the battery pack leaks and the fluid gets into your eye, do not rub the eye. Rinse well with water and immediately seek medical care. If left untreated, the battery fluid could cause damage to the eye. • • • CAUTION • • • • • • • • Always charge the battery at 32° – 104°F (0° - 40°C) temperature range. Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. The use of any other power supplies can damage the device and void your warranty. Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite. Do not place the battery in or near fire, on stoves or other high temperature locations. Do not place the battery in direct sunlight, or use or store the battery inside cars in hot weather. Doing so may cause the battery to generate heat, explode or ignite. Using the battery in this manner may also result in a loss of performance and a shortened life expectancy. Do not place the battery in microwave ovens, high-pressure containers or on induction cookware. Immediately discontinue use of the battery if, while using, charging or storing the battery, the battery emits an unusual smell, feels hot, changes color or shape, or appears abnormal in any other way. Do not replace the battery pack when the device is turned on. Do not remove or damage the battery pack’s label. Do not use the battery pack if it is damaged in any part. Battery pack usage by children should be supervised. As with other types of batteries, Lithium-Ion (LI) batteries will lose capacity over time. Capacity deterioration is noticeable after one year of service whether the battery is in use or not. It is difficult to precisely predict the finite life of a LI battery, but cell manufacturers rate them at 500 charge cycles. In other words, the batteries should be expected to take 500 full discharge / charge cycles before needing replacement. This number is higher if partial discharging / recharging is adhered to rather than full / deep discharging, . Storage of batteries for long time at fully charged status or at fully discharged status should be avoided. Only in case of long storage, to avoid deep discharge of the battery it is recommended to partially recharge the battery every three months to keep the charge status at a medium level. As a reference, run a fast recharge for 20 minutes every three months on unused products to avoid any performance deterioration of the cell. The useful life of LI batteries depends on usage and number of charges, etc., after which they should be removed from service, especially in mission critical applications. Do not continue to use a battery showing excessive loss of capacity, it should be properly recycled / disposed of and replaced. Collect and recycle waste batteries separately from the device in compliance with European Directive 2006/66/EC, 2002/95/EC, 2002/96/EC and subsequent modifications, US and China regulatory and others laws and regulations about the environment. Product Reference Guide 15 Introduction Programming the Reader Configuration Methods Programming Barcodes The reader is factory-configured with a standard set of default features. After scanning the interface barcode, you can select other options and customize your reader through use of the instructions and programming barcode labels available in the corresponding features section for your interface. Customizable settings for many features are found in "Configuration Using Barcodes" starting on page 37. Some programming labels, like "Restore Custom Defaults"on page 34, require only the scan of the single label to enact the change. Most, however, require the reader to be placed in Programming Mode prior to scanning them. Scan an ENTER/EXIT barcode once to enter Programming Mode. Once the reader is in Programming Mode, scan a number of parameter settings before scanning the ENTER/EXIT barcode a second time, which will then accept your changes, exit Programming Mode and return the reader to normal operation. There are some exceptions to the typical programming sequence described above. Please read the description and setting instructions carefully when configuring each programmable feature. Datalogic Aladdin™ Datalogic Aladdin™ is a multi-platform utility program providing a quick and user-friendly configuration method via the RS-232/USB-COM interface. Aladdin is available on the CDROM provided with your product, and also from the Datalogic website. Aladdin allows you to program the reader by selecting configuration commands through a user-friendly graphical interface running on a PC. These commands are sent to the reader over the selected communication interface, or they can be printed as barcodes to be scanned. Aladdin also provides the ability to perform a software upgrade for the connected device (see the Datalogic Aladdin™ Help On-Line for more details). 16 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Chapter 2 Setup Unpacking Check carefully to ensure the reader and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact Datalogic Technical Support. Information is shown on page 10. KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container. Setting Up the Reader Depending on whether you are using a Corded or Mobile version of the Gryphon, follow the steps provided in this section to connect and get your reader up and communicating with its host. 1. Begin by Installing the Interface Cable (Corded) or Connecting the Base Station (Mobile) 2. Go to Interface Selection and set the desired interface. 3. Configure Interface Settings (only if not using factory settings for that interface) 4. Go to Configuring Other Features (if modifications are needed from factory settings) Product Reference Guide 17 Setup Installing the Interface Cable For Corded versions, connect the reader cable by inserting the cable into the handle as shown in Figure 3. To remove it, insert a paper clip into the release aperture, then unplug the cable. Figure 3. Connect/disconnect the cable RS-232 Serial Connection Turn off power to the terminal/PC and connect the reader to the terminal/PC serial port via the RS-232 cable as shown in Figure 4. If the terminal will not support POT (Power Off the Terminal) to supply reader power, use the approved power supply (AC Adapter). Plug the AC Adapter barrel connector into the socket on the RS-232 cable connector and the AC Adapter plug into a standard power outlet. Figure 4. RS-232 Connection 18 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Installing the Interface Cable Keyboard Wedge Connection The Keyboard Wedge cable has a ‘Y’ connection from the reader. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC. Reference Figure 5. Figure 5. Keyboard Wedge Interface connection USB Connection Connect the reader to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered. Reference Figure 6. Figure 6. USB connection Other connection types are described below and illustrated in Figure 7. Product Reference Guide 19 Setup B Figure 7. Other Interface Connections US Ke or... IB M W yboa ed rd ge or... Specific cables are required for connection to different hosts. The connectors illustrated above are examples only. Actual connectors may vary from those illustrated, but the steps to connect the reader remain the same. RF Models The power supply connects directly to the base (not on the cable's jack) for all configurations. For all interfaces (except RS-232) a power supply is recommended but not necessary, because the base can be powered from the Host. When the base is powered from the Host, select a slow charge rate. Configuring the Base Station The base charger/station may be configured in desk application to hold the reader in two different positions, either a horizontal or standing position, in order to provide the most comfortable use depending on needs. Standing 20 Horizontal Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Configuring the Base Station Changing the Base Station Position The base station is configured by installing one of two sets of mechanical parts that come with the cordless kit. The default mounts (shown below) provide three options: vertical (wall) mounting, standing (45°), or horizontal mounting with a higher mechanical retention of the scanner. Use the other mounts only for horizontal mounting, with lower retention of the scanner. The different parts may be interchanged to customize retention preferences. A tool such as a rigid pen or a flat screwdriver can be used to change the mounts. Do not allow it to touch the contacts. 1. Insert the appropriate parts for the desired base station position, as shown below. Standing, Horizontal or Vertical Horizontal Only To ensure best contact and performance, do not intermix the parts of the two different mount sets. CAUTION 2. Using your thumbs, push open the plastic tabs on the bottom of the base to free the wing holders. Tab Tab Product Reference Guide 21 Setup 3. The stand can now be repositioned in either horizontal or standing position. Horizontal Standing Connecting the Base Station Figure 8 shows how to connect the Base Station to a terminal, PC or other host device. Turn off the host before connection and consult the manual for that equipment (if necessary) before proceeding. Connect the interface cable before applying power to the Base Station. The Gryphon GBT4100 can be set up to require a PIN code when connecting to the host. To connect to a system that uses a custom security PIN, follow the procedure in "Connecting the Base when Security Pin is Enabled" on page 25. For information on how to configure this feature, see BT Security Mode, starting on page 280. Base Station Connection and Routing: Fully insert the Power Cable and Interface (I/F) Cable connectors into their respective ports in the underside of the Base Station (see Figure 8). Then connect to an AC Adapter, and plug the AC power cord into the (wall) outlet. Gryphon Mobile can also be Powered by the Terminal. The external power supply is recommended but not necessary. When powered by the Terminal, the battery charger is automatically set as Slow charge. For some specific interfaces or hosts or lengths of cable, the use of an external power supply may be recommended for full recharging capability (see "Technical Specifications, starting on page 327" for more details). 22 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Configuring the Base Station Figure 8. Connecting the Base Station Wall plug Connector I/F Cable AC/DC Adapter DC Power Cord Base Station Securing the DC Power Cord (Optional) The DC power cord for the adapter can be secured to the bottom of the base in order to maximize the mechanical retention of the cable itself. The routing of the power cord can be changed to accommodate the base station positioning: horizontal, stand or wall mounting. The cables can be looped around to the front of the Base Station, or fed directly out the back of the Base Station, as shown in Figure 9. Figure 9. Options for routing the DC cord Please refer to the arrows depicted on the bottom of the base when placing the cables, detailed in Figure 10. Product Reference Guide 23 Setup Figure 10. Arrows showing routing Host Connection: Verify before connection that the reader’s cable type is compatible with your host equipment. Most connections plug directly into the host device as shown below. Keyboard Wedge interface cables have a ‘Y’ connection where its female end mates with the male end of the cable from the keyboard and the remaining end at the keyboard port on the terminal/PC. B Figure 11. Connecting to the Host Wa Ke W or... nd US yb ed oard ge or... M or... IB Power Connection : Plug the AC Adapter in to an approved AC wall socket with the cable facing downwards (as shown in Figure 8) to prevent undue strain on the socket. Gryphon Mobile can also be Powered by the Terminal. The external power supply is recommended but not necessary. When powered by the Terminal, the battery charger is automatically set as Slow charge. Disconnecting the Cable: To detach the cable, insert a paper clip or similar object into the hole on the base, as shown in Figure 12. 24 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Configuring the Base Station Figure 12. Disconnecting the Cable Insert Paper Clip Connecting the Base when Security Pin is Enabled When connecting the Base to a system that has a custom Security Pin enabled, follow the steps below in the order shown: 1. Power down the host system. 2. Connect the appropriate interface cable into the Base as shown in Figure 11 on page 24. 3. Place the reader in the Base. 4. Power up the host. The reader will link to the Base. 5. When the host completely powers up, a new custom Security Pin Code may be sent to the reader and Base, depending on host configuration. Contact Datalogic Technical Support for more information. To change security settings or set up a PIN, see BT Security Mode, starting on page 280. Linking the Reader to a Base Station RF Devices For RF devices, before configuring the interface it is necessary to link the handheld with the base. To link the handheld and the base, press the trigger to wake it and place it on the base. If the reader was previously linked to another base, you must first scan the Unlink action command before re-linking to the new base. Unlink Product Reference Guide 25 Setup BT Models only Remember: The mandatory condition for establishing a new linking between a BT handheld and a BT base is that the handheld is unlinked and they share the same security configuration. A successful link is indicated by three ascending tones from the reader. A high-low-high-low tone indicates the link attempt was unsuccessful. A single green LED flash after this tone indicates no Base Station was discovered. Two green LED flashes after this tone indicates that more than one Base Station was discovered and the reader did not link. Three LED flashes after this tone indicate a security error. Linking a BT Reader to a PC The reader can optionally be linked to a Bluetooth-enabled PC with the serial port profile, in either server mode or client mode, or with human interface device profile (HID). Linking to a PC in Server Mode (BT Slave Mode) To link a BT reader in server mode to a Bluetooth-enabled PC, follow these steps: 1. Install any drivers provided with the Bluetooth adapter. 2. Scan the Link to a PC in Server Mode barcode to make the scanner visible to the host computer.. Link to a PC in Server Mode 3. Use the host computer’s Bluetooth manager to “Discover new devices” and select "Datalogic Scanner." If you receive an error message, it may be necessary to disable security on the device. 4. Select “connect” on the PC to link the reader to the PC. Use an RS-232 terminal program to see incoming data on the port designated by the computer's Bluetooth manager. Linking to a PC in Client Mode (BT Master Mode) The reader can optionally be linked in client mode to a Bluetooth-enabled PC with the serial port profile. To do this, follow these steps: 1. Ensure the PC or terminal can network with Bluetooth devices and that it is powered on. 2. Ensure that a COM port is assigned under Services within the Bluetooth setup menu. 3. Create a Link label that contains the address of the PC Bluetooth adapter. The Bluetooth address can be found under "Properties" within in the Bluetooth setup menu. NOTE 26 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 GRYPHON™ I System and Network Layouts The link label is a Code 128 function 3 label with the following format: <FN3 char>LnkB<12 character bluetooth address> 4. Scan the link label you created in step 3. Linking to a PC in HID 1. Install any drivers provided with the Bluetooth adapter. 2. Scan the Link to a PC in HID barcode below to make the scanner visible to the host computer. Link to a PC in HID 3. Use the host computer's Bluetooth manager to "Discover new devices" and select "Datalogic Scanner." If you receive an error message, it may be necessary to disable security on the device. 4. Select "connect" on the PC to link the reader to the PC. Use a text editing program to see incoming data from the reader. GRYPHON™ I System and Network Layouts Stand Alone Layouts Figure 13. Single Reader Layout Product Reference Guide 27 Setup Figure 14. Multiple Reader Layout Gryphon M4100 only (not valid for BT model) In stand alone systems, each cradle is connected to a single Host. Figure 15. Multiple Stand Alone Layouts Gryphon M4100 only (not valid for BT model) Many stand alone connections can operate in the same physical area without interference, provided all readers and cradles in the system have different addresses. 28 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Interface Selection Interface Selection Upon completing the physical connection between the reader and its host, proceed to Table 1 starting on page 30 to select the interface type the reader is connected to (for example: RS-232, Keyboard Wedge, USB, etc.). Scan the appropriate barcode in that section to configure your system’s correct interface type. Each reader model will support one of the following sets of host interfaces: • • • • • General Purpose Models RS-232 RS-232 OPOS USB Keyboard Wedge Wand Emulation • • • • Retail Point of Sale Models RS-232 RS-232 OPOS USB IBM 46XX Setting the Interface Scan the programming barcode from this section which selects the appropriate interface type matching the system the reader will be connected to. Next, proceed to the corresponding section in this manual (also listed in Table 1 starting on page 30) to configure any desired settings and features associated with that interface. Unlike some programming features and options, interface selections require that you scan only one programming barcode label. DO NOT scan an ENTER/EXIT barcode prior to scanning an interface selection barcode. Some interfaces require the scanner to start in the disabled state when powered up. If additional scanner configuration is desired while in this state, pull the trigger and hold it for five seconds. The scanner will change to a state that allows programming with barcodes. Product Reference Guide 29 Setup Table 1. Available Interfaces RS-232 FEATURES RS-232 standard interface Select RS232-STD RS-232 Wincor-Nixdorf Set RS-232 Interface Features Select RS232-WN starting on page 41 RS-232 for use with OPOS/UPOS/JavaPOS Select RS-232 OPOS USB Com to simulate RS-232 standard interface Select USB-COM-STDa IBM FEATURES IBM-46xx Port 5B reader interface Set IBM Interface Features Select IBM-P5B starting on page 69 IBM-46xx Port 9B reader interface Select IBM-P9B USB-OEM FEATURES USB-OEM (can be used for OPOS/UPOS/JavaPOS) Select USB-OEM Set USB-OEM Interface Features starting on page 67 a. Download the correct USB Com driver from www.datalogic.com 30 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Interface Selection KEYBOARD FEATURES AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding Select KBD-AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD-AT-NK AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key Select KBD-AT-ALT Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard Set KEYBOARD WEDGE Interface Features starting on page 55 Select KBD-AT-ALT-NK PC/XT w/Standard Key Encoding Select KBD-XT Keyboard Wedge for IBM Terminal 3153 Select KBD-IBM-3153 Product Reference Guide 31 Setup KEYBOARD — cont. FEATURES Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard Select KBD-IBM-M Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard Select KBD-IBM-MB Keyboard Wedge for DIGITAL Terminals VT2xx, VT3xx, VT4xx Select KBD-DIG-VT USB Keyboard with standard key encoding Set KEYBOARD WEDGE Interface Features starting on page 55 Select USB Keyboard USB Keyboard with alternate key encoding Select USB Alternate Keyboard USB Keyboard for Apple computers Select USB-KBD-APPLE WAND EMULATION FEATURES Set WAND Interface Features Wand Emulation Select WAND 32 starting on page 73 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Customizing Configuration Settings Customizing Configuration Settings Configure Interface Settings If after scanning the interface barcode from the previous table, your installation requires you to select options to further customize your reader, turn to the appropriate section for your interface type in "Configuration Using Barcodes" starting on page 37. • "RS-232 ONLY Interface" on page 41 • "RS-232/USB-Com Interfaces" on page 46 • "Keyboard Interface" on page 55 • "USB-OEM Interface" on page 67 • "IBM 46XX Interface" on page 69 • "Wand Emulation Interface" on page 73 Global Interface Features See "Global Interface Features" on page 39 for settings configurable by all interface types. Configuring Other Features If your installation requires different programming than the standard factory default settings, the following sections of this manual allow configuration of non-interface-specific settings you might require: Reading Parameters: Reading Parameters include programming for scanning, beeper and LED indicators and other universal settings. Code Selection: Includes options concerning the barcode label types (symbologies). These settings allow you to enable/disable symbologies, set label lengths, require check digit, etc. Wireless Features: Contains programming options for RF and Bluetooth models only. Laser Features: Describes options and programming specific to laser models. Software Version Transmission The software version of the device can be transmitted over the RS-232 and Keyboard interfaces by scanning the following label. Transmit Software Version Product Reference Guide 33 Setup Resetting the Product Configuration to Defaults Restore Custom Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want to restore the Custom Default Configuration that may have been saved in the scanner, scan the Restore Custom Default Configuration barcode below. This will restore the custom configuration for the currently active interface. Custom defaults are based on the interface type. Configure the imager for the correct interface before scanning this label. Restore Custom Default Configuration Restore Factory Configuration If you want to restore the Factory Configuration for your imager, scan either the Restore USA Factory Configuration barcode or the Restore EU Factory Configuration barcode below. Both labels restore the scanner configuration to the factory settings, including the interface type. The USA label restores Label IDs to those historically used in the USA. The EU label restores Label IDs to those historically used in Europe. The Label ID sets for USA and EU are shown in the “Label ID” section on page 81 of this manual. Restore USA Factory Configuration Restore EU Factory Configuration The programming items listed in the following sections show the factory default settings for each of the menu commands. 34 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Customizing Configuration Settings Replacing the Battery Before replacing the Battery, read "Battery Safety" starting on page 14. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum performance. To change the battery of your reader, complete the following instructions. 1. With a screwdriver, unscrew the battery cover screw. 2. Unscrew and remove the three screws securing the battery holder, and unplug the white connector. Screw Connector Screw Screw 3. Carefully lift out the gold contacts circuit, and remove the battery holder while letting the white connector pass through the hole in the battery holder (as shown in the picture below). Pass-through hole Product Reference Guide 35 Setup 4. Remove the old battery from its place (if present), and insert the new battery in the same position. 5. Replace the battery holder and three screws, plug in the connector, and return the contacts circuit to its previous location. When inserting the new battery into the handle, take care to position the battery and the connector as shown. 6. Insert the cover in the handle and screw it back into place. Battery replacement is now complete. 36 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Chapter 3 Configuration Using Barcodes This and following sections provide programming barcodes to configure your reader by changing the default settings. For details about additional methods of programming, see Configuration Methods on page 16. You must first enable your reader to read barcodes in order to use this section. If you have not done this, go to Setup, starting on page 17 and complete the appropriate procedure. Configuration Parameters Once the reader is set up, you can change the default parameters to meet your application needs. Refer to "Standard Defaults" starting on page 335 for initial configuration in order to set the default values and select the interface for your application. The following configuration parameters are applicable to all Gryphon models covered in this manual, unless otherwise indicated. The items are divided into logical groups, making it easy to find the desired function based on its reference group. Interface Configuration: • • • "RS-232 ONLY Interface" on page 41 "RS-232/USB-Com Interfaces" on page 46 "Keyboard Interface" on page 55 • • • "USB-OEM Interface" on page 67 "IBM 46XX Interface" on page 69 "Wand Emulation Interface" on page 73 Parameters common to all interface applications: • • "Data Format" on page 77 gives options to control the messages sent to the Host system. "Reading Parameters" on page 91 control various operating modes and indicators status functioning. Symbology-specific parameters: • "Code Selection" on page 107 provides configuration of a personalized mix of codes, code families and their options. Model-specific parameters: • • "Wireless Features" on page 257 offers configuration of radio control parameters for RF and Bluetooth models. "Laser Features" on page 287 provides options specific to laser models. Product Reference Guide 37 Reading Configuration Barcodes You must first enable your reader to read barcodes in order to use this section. If you have not done this, go to Setup, starting on page 17 and complete the appropriate procedure. To program features: 1. Scan the ENTER/EXIT PROGRAMMING barcode, available at the top of each programming page, when applicable. 2. Scan the barcode to set the desired programming feature. You may need to cover unused barcodes on the page, and possibly the facing page, to ensure that the reader reads only the barcode you intend to scan. 3. If additional input parameters are needed, go to Appendix D, Keypad, and scan the appropriate characters from the keypad. Additional information about many features can be found in the “References” chapter. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 4. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING barcode to exit Programming Mode. For detailed descriptions, programming information and examples for setting selected configuration items, see References, starting on page 291. 38 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Host Commands — Obey/Ignore GLOBAL INTERFACE FEATURES The following interface features are configurable by all interface types. Host Commands — Obey/Ignore This option specifies whether the reader will obey or ignore host commands. When set to ignore, the reader will ignore all host commands except for those necessary for: • service mode • flash programming mode • keeping the interface active • transmission of labels. DEFAULT Host Commands = Obey Host Commands = Ignore USB Suspend Mode This setting enables/disables the ability of USB interfaces to enter suspend mode. DEFAULT USB Suspend Mode = Disable USB Suspend Mode = Enable Product Reference Guide 39 Global Interface Features ENTER/EXIT PROGRAMMING MODE NOTES 40 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 RS-232 ONLY INTERFACE BAUD RATE on page 42 DATA BITS on page 43 STOP BITS on page 43 PARITY on page 44 HANDSHAKING CONTROL on page 45 Use the programming barcodes in this section if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in the next section, "RS-232/USB-Com Interfaces" starting on page 46. Reference Appendix B, Standard Defaults for a listing of standard factory settings. Product Reference Guide 41 ENTER/EXIT PROGRAMMING MODE Baud Rate See page 291 for information on this feature. Baud Rate = 1200 Baud Rate = 2400 Baud Rate = 4800 DEFAULT Baud Rate = 9600 Baud Rate = 19,200 Baud Rate = 38,400 Baud Rate = 57,600 Baud Rate = 115,200 42 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Data Bits Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data. 7 Data Bits DEFAULT 8 Data Bits Stop Bits Set the number of stop bits to match host device requirements. See page 291 for more information on this feature. DEFAULT 1 Stop Bit 2 Stop Bits Product Reference Guide 43 ENTER/EXIT PROGRAMMING MODE Parity This feature specifies parity required for sending and receiving data. Select the parity type according to host device requirements. See page 291 for more information. DEFAULT Parity = None Parity = Even Parity = Odd 44 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Handshaking Control Handshaking Control See page 291 for more information about this feature. DEFAULT Handshaking Control = RTS Handshaking Control = RTS/CTS Handshaking Control = RTS/XON/XOFF Handshaking Control = RTS On/CTS Handshaking Control = RTS/CTS Scan Control Product Reference Guide 45 RS-232/USB-COM INTERFACES INTERCHARACTER DELAY on page 47 BEEP ON ASCII BEL on page 47 BEEP ON NOT ON FILE on page 48 ACK NAK OPTIONS on page 49 ACK CHARACTER on page 50 NAK CHARACTER on page 50 ACK NAK TIMEOUT VALUE on page 51 ACK NAK RETRY COUNT on page 51 ACK NAK ERROR HANDLING on page 52 INDICATE TRANSMISSION FAILURE on page 52 DISABLE CHARACTER on page 53 ENABLE CHARACTER on page 53 The programming barcodes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces. Reference Appendix B, Standard Defaults for a listing of standard factory settings. Product Reference Guide 46 ENTER/EXIT PROGRAMMING MODE Intercharacter Delay Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. See page 292 for more information. Intercharacter Delay = No Delay Select Intercharacter Delay Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 00 = No Intercharacter Delay Beep On ASCII BEL When this parameter is enabled, the reader issues a beep when a <BEL> character is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other important event. DEFAULT Beep On ASCII BEL = Disable Beep On ASCII BEL = Enable Product Reference Guide 47 ENTER/EXIT PROGRAMMING MODE Beep On Not on File This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command. Beep On Not On File = Disable DEFAULT Beep On Not On File = Enable 48 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE ACK NAK Options ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. See page 293 for more information. DEFAULT ACK/NAK Protocol = Disable ACK/NAK ACK/NAK Protocol = Enable for label transmission ACK/NAK Protocol = Enable for host-command acknowledge ACK/NAK Protocol = Enable for label transmission and hostcommand acknowledge Product Reference Guide 49 ENTER/EXIT PROGRAMMING MODE ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 293 for more information. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. Select ACK Character Setting DEFAULT 0x06 ‘ACK’ Character NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 294 for more information. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. Select NAK Character Setting DEFAULT 50 0x15 ‘NAK’ Character Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE ACK NAK Timeout Value ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. See page 295 for more information on setting this feature. Select ACK NAK Timeout Value Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 01 ACK NAK Timeout value is 200ms ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. See page 296 for more information. Select ACK NAK Retry Count Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 003 = 3 Retries 51 ENTER/EXIT PROGRAMMING MODE ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host. DEFAULT ACK NAK Error Handling = Ignore Errors Detected ACK NAK Error Handling = Process Error as Valid ACK Character ACK NAK Error Handling = Process Error as Valid NAK Character Indicate Transmission Failure This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode. Indicate Transmission Failure = Disable Indication DEFAULT Indicate Transmission Failure = Enable Indication 52 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Disable Character Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. See page 297 for more information on setting this feature. Select Disable Character Setting DEFAULT 0x44 = Disable Character is ‘D’ Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. See page 298 in “References” for more information on setting this feature. Select Enable Character Setting DEFAULT Product Reference Guide 0x45 = Enable Character is ‘E’ 53 ENTER/EXIT PROGRAMMING MODE NOTES 54 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 KEYBOARD INTERFACE COUNTRY MODE on page 56 CAPS LOCK STATE on page 59 NUMLOCK on page 60 SEND CONTROL CHARACTERS on page 61 WEDGE QUIET INTERVAL on page 62 INTERCHARACTER DELAY on page 63 INTERCODE DELAY on page 64 USB KEYBOARD SPEED on page 65 USB KEYBOARD NUMERIC KEYPAD on page 66 Use the programming barcodes in this chapter to select options for USB Keyboard and Wedge Interfaces. Reference Appendix B, Standard Defaults for a listing of standard factory settings. Information about control character emulation which applies to keyboard interfaces is listed in Appendix E, Scancode Tables. Product Reference Guide 55 ENTER/EXIT PROGRAMMING MODE Country Mode This feature specifies the country/language supported by the keyboard. Only the following interfaces support ALL Country Modes. • USB Keyboard (without alternate key encoding) • AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Std Key Encoding • Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard • AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 without Alternate Key • Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard • Bluetooth HID Profile All other interfaces support ONLY the following Country Modes: U.S., Belgium, Britain, France, Germany, Italy, Spain, Sweden. DEFAULT Country Mode = U.S. Country Mode = Belgium Country Mode = Britain Supports only the interfaces listed in the Country Mode feature description. Country Mode = Croatia Supports only the interfaces listed in the Country Mode feature description. Country Mode = Czech Republic 56 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Country Mode Country Mode — continued Supports only the interfaces listed in the Country Mode feature description. Country Mode = Denmark Country Mode = France Country Mode = French Canadian Country Mode = Germany Supports only the interfaces listed in the Country Mode feature description. Country Mode = Hungary Country Mode = Italy Supports only the interfaces listed in the Country Mode feature description. Country Mode = Japanese 106-key Product Reference Guide 57 ENTER/EXIT PROGRAMMING MODE Country Mode — continued Country Mode = Lithuanian Supports only the interfaces listed in the Country Mode feature description. Country Mode = Norway Supports only the interfaces listed in the Country Mode feature description. Country Mode = Poland Supports only the interfaces listed in the Country Mode feature description. Country Mode = Portugal Supports only the interfaces listed in the Country Mode feature description. Country Mode = Romania Supports only the interfaces listed in the Country Mode feature description. Country Mode = Slovakia Country Mode = Spain 58 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Caps Lock State Country Mode — continued Country Mode = Sweden Supports only the interfaces listed in the Country Mode feature description. Country Mode = Switzerland Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces and Bluetooth HID Profile. This does not apply when an alternate key encoding keyboard is selected. DEFAULT Caps Lock State = Caps Lock OFF Caps Lock State = Caps Lock ON Caps Lock State = AUTO Caps Lock Enable Product Reference Guide 59 ENTER/EXIT PROGRAMMING MODE Numlock This option specifies the setting of the Numbers Lock (Numlock) key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard. DEFAULT Numlock = Numlock key unchanged Numlock = Numlock key toggled 60 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Send Control Characters Send Control Characters This feature Specifies how the reader transmits ASCII control characters to the host. Reference Appendix E, Scancode Tables for more information about control characters. Options are as follows: Control Character 00 . Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1. Control Character 01 . Characters from 00 to 0x1F are sent as control character Ctrl+Capital Key, special keys are located from 0x80 to 0xA1. Control Character 02 . Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table (Microsoft Windows Codepage 1252 — see "Microsoft Windows Codepage 1252"on page 363). DEFAULT Wedge Send Control Characters = 00 Wedge Send Control Characters = 01 Wedge Send Control Characters = 02 Product Reference Guide 61 ENTER/EXIT PROGRAMMING MODE Wedge Quiet Interval This option specifies the amount of time to look for keyboard activity before the reader breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments. This feature applies ONLY to the Keyboard Wedge interface. See page 299 in “References” for detailed information and examples for setting this feature. Select Wedge Quiet Interval Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 62 10 = Quiet Interval of 100 ms Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Intercharacter Delay Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. This feature applies ONLY to the Keyboard Wedge interface and Bluetooth HID Profile. See page 300 in “References” for detailed information and examples for setting this feature. Intercharacter Delay = No Delay Select Intercharacter Delay Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 00 = No Intercharacter Delay 63 ENTER/EXIT PROGRAMMING MODE Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. See page 301 in “References” for detailed information and examples for setting this feature. Set Intercode Delay Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 64 00 = No Wedge Intercode Delay Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard. This feature applies ONLY to the USB Keyboard interface. DEFAULT USB Keyboard Speed = 1ms USB Keyboard Speed = 2ms USB Keyboard Speed = 3ms USB Keyboard Speed = 4ms USB Keyboard Speed = 5ms USB Keyboard Speed = 6ms Product Reference Guide 65 ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed — continued USB Keyboard Speed = 7ms USB Keyboard Speed = 8ms USB Keyboard Speed = 9ms USB Keyboard Speed = 10ms USB Keyboard Numeric Keypad This option Controls whether numeric characters will be sent using standard keys or the numeric keypad. DEFAULT Standard Keys Numeric Keypad 66 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 USB-OEM INTERFACE USB-OEM DEVICE USAGE on page 68 INTERFACE OPTIONS on page 68 Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter and "IBM 46XX Interface"on page 69 to specifically configure for the USB-OEM interface. Other USB interfaces are included in the appropriate chapter for their host type. Reference Appendix B, Standard Defaults for a listing of standard factory settings. Product Reference Guide 67 ENTER/EXIT PROGRAMMING MODE USB-OEM Device Usage The USB-OEM protocol allows for the reader to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate. Options are: • Table Top Scanner • Handheld Scanner It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system. USB-OEM Device Usage = Table Top Scanner DEFAULT USB-OEM Device Usage = Handheld Scanner Interface Options This feature provides for an interface-specific control mechanism. Obey Scanner Configuration Host Commands DEFAULT Ignore Scanner Configuration Host Commands 68 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 IBM 46XX INTERFACE 46XX NUMBER OF HOST RESETS on page 70 TRANSMIT LABELS IN CODE 39 FORMAT on page 72 INTERFACE OPTIONS on page 72 Use the barcodes in this section to configure programmable features for available IBM 46XX interfaces. Reference Appendix B, Standard Defaults for a listing of standard factory settings. Product Reference Guide 69 ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets Specifies how many consecutive resets are processed before the reader starts a five-second period to allow the user to enter Programming Mode and configure the reader. The configurable range for this feature is 1 to 15 resets. 46xx Number of Host Resets = 1 46xx Number of Host Resets = 2 46xx Number of Host Resets = 3 46xx Number of Host Resets = 4 46xx Number of Host Resets = 5 DEFAULT 46xx Number of Host Resets = 6 46xx Number of Host Resets = 7 70 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets 46xx Number of Host Resets — cont. 46xx Number of Host Resets = 8 46xx Number of Host Resets = 9 46xx Number of Host Resets = 10 46xx Number of Host Resets = 11 46xx Number of Host Resets = 12 46xx Number of Host Resets = 13 46xx Number of Host Resets = 14 46xx Number of Host Resets = 15 Product Reference Guide 71 ENTER/EXIT PROGRAMMING MODE Transmit Labels in Code 39 Format This feature enable/disables translation to Code 39 before transmitting label data to an IBM46XX or a USB-OEM host. Only the symbology identifier is modified for the translation. The data is not converted to Code 39 or verified to be valid for Code 39. Options are: IBM Standard Format. Send labels in standard IBM format. Code 39 Format. Translate the following symbologies to Code 39: • USB-OEM: Code128, Code 93, and Codabar • IBM-Port 5B: Code 128, Code 93, and Codabar • IBM-Port 9B: Code 93 and Codabar DEFAULT Transmit Labels in Code 39 Format = IBM Standard Format Transmit Labels in Code 39 Format = Code 39 Format Interface Options This feature provides for an interface-specific control mechanism. Obey Scanner Configuration Host Commands DEFAULT Ignore Scanner Configuration Host Commands 72 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 WAND EMULATION INTERFACE WAND SIGNAL SPEED on page 74 WAND POLARITY on page 74 WAND IDLE STATE on page 75 TRANSMIT NOISE on page 75 LABEL SYMBOLOGY CONVERSION on page 76 This chapter provides feature/settings configuration for the Wand Emulation interface. Reference Appendix B, Standard Defaults for a listing of standard factory settings. Product Reference Guide 73 ENTER/EXIT PROGRAMMING MODE Wand Signal Speed This feature specifies the speed of the Wand output signal per nominal bar or space. Choices are: • 330 microseconds • 660 microseconds Wand Signal Speed = 330ms DEFAULT Wand Signal Speed = 660ms Wand Polarity This option specifies the polarity of the Wand output signal. Choices are: • Quiet zones and spaces are high, bars are low • Quiet zones and spaces are low, bars are high TTL logic levels: 0V <= Low <= 0.7V 2.4V <= High <= 5.25V Wand Polarity = Quiet Zones & Spaces High, Bars Low DEFAULT Wand Polarity = Quiet Zones & Spaces Low, Bars High 74 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Wand Idle State Wand Idle State This feature specifies the level of the Wand output signal when the reader is idle. TTL logic levels: 0V <= Low <= 0.7V 2.4V <= High <= 5.25V Wand Idle State = Low DEFAULT Wand Idle State = High Transmit Noise This option specifies the leading/trailing noise for the Wand interface. DEFAULT Transmit Noise = Disable Transmit Noise = Transmit leading noise Transmit Noise = Transmit trailing noise Transmit Noise = Transmit leading and trailing noise Product Reference Guide 75 ENTER/EXIT PROGRAMMING MODE Label Symbology Conversion When this feature is enabled for the Wand Emulation interface, all barcode labels are converted to a single symbology. Options are: • No conversion • Convert to Code 39 symbology • Convert to Code 39 Full ASCII • Convert to Code 128 symbology DEFAULT Label Symbology Conversion = No conversion Label Symbology Conversion = Convert to Code 39 Label Symbology Conversion = Convert to Code 39 Full ASCII Label Symbology Conversion = Convert to Code 128 76 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 DATA FORMAT GLOBAL PREFIX/SUFFIX on page 78 GLOBAL AIM ID on page 79 GS1-128 AIM ID on page 80 LABEL ID starting on page 81 • • • • • Label ID: Pre-loaded Sets Label ID: Set Individually Per Symbology Label ID Control Label ID Symbology Selection Set Global Mid Label ID Characters CASE CONVERSION on page 90 CHARACTER CONVERSION on page 90 It is not recommended to use these features with IBM interfaces. CAUTION The features in this chapter can be used to build specific user-defined data into a message string. See “References” starting on page 304 for more detailed instructions on setting these features. Product Reference Guide 77 ENTER/EXIT PROGRAMMING MODE Global Prefix/Suffix This option sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. The characters may be added as a prefix (in a position before the barcode data, also called a header) and/or as a suffix (in a position following the barcode data, also called a footer). See page 305 for more detailed instructions on setting this feature. To configure this feature, scan the ENTER/EXIT PROGRAMMING MODE barcode above to place the unit in Programming Mode, then the “Set Global Prefix” or “Set Global Suffix,” barcode followed by the digits (in hex) from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). If less than the expected string of 20 characters are selected, scan the ENTER/EXIT barcode to terminate the string. Exit programming mode by scanning the ENTER/EXIT barcode again. Set Global Prefix Set Global Suffix Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 78 No Global Prefix Global Suffix = 0x0D (CR) Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Global AIM ID Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by... • A code character (see the table below), followed by... • A modifier character (the modifier character is symbol dependent). SYMBOLOGY CHAR SYMBOLOGY CHAR UPC/EAN Ea Code 128/GS1-128 C Code 39 and Code 32 A DataBar Omnidirectional, DataBar Expanded e Codabar F Standard 2 of 5 S Interleaved 2 of 5 I ISBN Xb Code 93 G Code 11 H a. UPC-A and UPC-E labels are converted to EAN 13 when adding AIM IDs. b. ISBN (X with a 0 modifier character) DEFAULT Global AIM ID = Disable Global AIM ID = Enable Product Reference Guide 79 ENTER/EXIT PROGRAMMING MODE GS1-128 AIM ID If Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled independently. The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3. AIM IDs for other symbologies can be enabled/disabled independently as well. Contact Customer Support for assistance GS1-128 AIM ID = Disable DEFAULT GS1-128 AIM ID = Enable 80 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Label ID Label ID A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x010xFF), used to identify a barcode (symbology) type. It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs as a pre-loaded set (see "Label ID: Pre-loaded Sets" below) or individually per symbology (see "Label ID: Set Individually Per Symbology" on page 81). If you wish to program the reader to always include an industry standard label identifier for ALL symbology types, see the previous feature "Global AIM ID" on page 79. See Label ID, starting on page 307 of “References” for more information on setting this feature. Label ID: Pre-loaded Sets The reader supports two pre-loaded sets of Label IDs. See Label ID: Pre-loaded Sets, starting on page 307 for details on the USA set and the EU set. CAUTION When changing from one Label ID set to another, all other reader configuration settings, including the host interface type, will be erased and set to the standard factory defaults. Any custom configuration or custom defaults will be lost. DEFAULT Label ID Pre-loaded Set = USA Set Label ID Pre-loaded Set = EU Set Label ID: Set Individually Per Symbology This feature configures a Label ID individually for a single symbology. See Label ID: Set Individually Per Symbology, starting on page 309 for detailed instructions on setting this feature. Product Reference Guide 81 ENTER/EXIT PROGRAMMING MODE Label ID Control This option controls whether a Label ID is disabled, or sent as a prefix or suffix for a given symbology type. DEFAULT Label ID Transmission = Disable Label ID Transmission = Enable as Prefix Label ID Transmission = Enable as Suffix Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 82 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection Label ID Symbology Selection This option selects the symbology for which a Label ID is to be configured. See "Label ID" on page 81 or page 309 in “References” for more detailed instructions. Set UPC-A Label ID Character(s) Set UPC-A/P2 Label ID Character(s) Set UPC-A/P5 Label ID Character(s) Set UPC-A/GS1-128 Label ID Character(s) Set UPC-E Label ID Character(s) Set UPC-E/P2 Label ID Character(s) Set UPC-E/P5 Label ID Character(s) Product Reference Guide 83 ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection — continued Set UPC-E/GS1-128 Label ID Character(s) Set EAN 13 Label ID Character(s) Set EAN 13/P2 Label ID Character(s) Set EAN 13/P5 Label ID Character(s) Set EAN 13/GS1-128 Label ID Character(s) Set EAN 8 Label ID Character(s) Set EAN 8/P2 Label ID Character(s) 84 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection Label ID Symbology Selection — continued Set EAN 8/P5 Label ID Character(s) Set EAN 8/GS1-128 Label ID Character(s) Set GTIN Label ID Character(s) Set GTIN/P2 Label ID Character(s) Set GTIN/P5 Label ID Character(s) Set GTIN/GS1-128 Label ID Character(s) Set Code 39 Label ID Character(s) Product Reference Guide 85 ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection — continued Set Code 32 Label ID Character(s) Set Code 39 CIP Label ID Character(s) Set Code 128 Label ID Character(s) Set GS1-128 Label ID Character(s) Set ISBT 128 Label ID Character(s) Set Codablock F Label ID Character(s) Set Interleaved 2 of 5 Label ID Character(s) Set Follett 2 of 5 Label ID Character(s) 86 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection Label ID Symbology Selection — continued Set Interleaved 2 of 5 CIP HR Label ID Character(s) Set Standard 2 of 5 Label ID Character(s) Set Industrial 2 of 5 Label ID Character(s) Set IATA Label ID Character(s) Set Datalogic 2 of 5 Label ID Character(s) Set Codabar Label ID Character(s) Set ABC Codabar Label ID Character(s) Product Reference Guide 87 ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection — continued Set Code 11 Label ID Character(s) Set DataBar Omnidirectional Label ID Character(s) Set DataBar Expanded Label ID Character(s) Set DataBar Limited Label ID Character(s) Set Code 93 Label ID Character(s) Set MSI Label ID Character(s) Set Plessey Label ID Character(s) 88 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Set Global Mid Label ID Characters Label ID Symbology Selection — continued Set Anker Plessey Label ID Character(s) Set Code 4 Label ID Character(s) Set Code 5 Label ID Character(s) Set Global Mid Label ID Characters Specifies mid-label ID that is added for transmission between the labels of a two-label pair. To configure this feature, scan the ENTER/EXIT PROGRAMMING MODE barcode above to place the unit in Programming Mode, then the “Set Global Mid Label ID Character(s)” barcode followed by the digits (in hex) from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). If less than the expected string of 20 characters are selected, scan the ENTER/EXIT barcode to terminate the string. Exit programming mode by scanning the ENTER/EXIT barcode again. Set Global Mid Label ID Character(s) Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide No Mid Label ID Character (00) 89 ENTER/EXIT PROGRAMMING MODE Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case. Case conversion affects ONLY scanned barcode data, and does not affect Label ID, Prefix, Suffix, or other appended data. DEFAULT Case Conversion = Disable (no case conversion) Case Conversion = Convert to upper case Case Conversion = Convert to lower case Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done. If less than the expected string of 16 characters are selected, scan the ENTER/ EXIT barcode twice to accept the selections and exit Programming Mode. Configure Character Conversion DEFAULT 90 0xFFFFFFFFFFFFFFFF (No character conversion) Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 READING PARAMETERS DOUBLE READ TIMEOUT on page 92 GOOD READ LED DURATION on page 100 LABEL GONE TIMEOUT on page 93 SCAN MODE on page 101 SLEEP MODE TIMEOUT on page 94 STAND MODE TRIGGERED TIMEOUT on page 102 POWER ON ALERT on page 96 STAND DETECTION on page 103 GOOD READ: WHEN TO INDICATE on page 96 STAND MODE SENSITIVITY on page 104 GOOD READ BEEP TYPE on page 97 SCANNING ACTIVE TIME on page 104 GOOD READ BEEP FREQUENCY on page 97 FLASH ON TIME on page 105 GOOD READ BEEP LENGTH on page 98 FLASH OFF TIME on page 105 GOOD READ BEEP VOLUME on page 99 GREEN SPOT DURATION on page 106 Product Reference Guide 91 ENTER/EXIT PROGRAMMING MODE Double Read Timeout Double Read Timeout prevents a double read of the same label by setting the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the specified timeout, the second read is ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label read. Double Read Timeout = 0.1 Second Double Read Timeout = 0.2 Second Double Read Timeout = 0.3 Second Double Read Timeout = 0.4 Second Double Read Timeout = 0.5 Second DEFAULT Double Read Timeout = 0.6 Second Double Read Timeout = 0.7 Second 92 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Label Gone Timeout Double Read Timeout — continued Double Read Timeout = 0.8 Second Double Read Timeout = 0.9 Second Double Read Timeout = 1 Second Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read. See page 312 in “References” for detailed instructions and examples for setting this feature. Select Label Gone Timeout Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 016 = Timeout of 160 ms 93 ENTER/EXIT PROGRAMMING MODE Sleep Mode Timeout This feature sets the amount of time that the reader will be idle before it enters into a low power Sleep Mode. When in Sleep Mode the reader can no longer receive commands from the Host or base station until it is woken up again by a trigger pull or being placed into a base station. In order for the reader to enter Sleep Mode, the following conditions must be met: Corded version (GD4100 only). RS-232 interface and trigger single, trigger multiple or trigger pulse. Mobile version (GM4100 only). Sleep state is allowed only on the handheld (not on the base) when trigger single, trigger multiple or trigger pulse are set, and when the reader is not charging the battery. This feature is not applicable to the Gryphon Laser or Gryphon BT models DEFAULT Sleep Mode Timeout = Disable Sleep Mode Timeout = 1 Second Sleep Mode Timeout = 2 Seconds Sleep Mode Timeout = 3 Seconds Sleep Mode $ Timeout = 4 Seconds 94 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Sleep Mode Timeout Sleep Mode Timeout — continued Sleep Mode Timeout = 5 Seconds Sleep Mode$ Timeout = 6 Seconds $ Timeout = 7 Seconds Sleep Mode Sleep Mode Timeout = 8 Seconds Sleep Mode Timeout = 9 Seconds Sleep Mode Timeout = 10 Seconds Product Reference Guide 95 LED and Beeper Indicators ENTER/EXIT PROGRAMMING MODE LED AND BEEPER INDICATORS Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power. Power On Alert = Disable (No Audible Indication) DEFAULT Power On Alert = Four Beeps Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a barcode. . This option, which uses CTS, is only valid for RS-232 interfaces. This item is not configurable for the GM4100/GBT 4100 models. DEFAULT Indicate Good Read = After Decode Indicate Good Read = After Transmit Indicate Good Read = After CTS Goes Inactive, Then Active 96 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Good Read Beep Type Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound. DEFAULT Good Read Beep Type = Mono Good Read Beep Type = Bitonal Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.) Good Read Beep Frequency = Low Good Read Beep Frequency = Medium DEFAULT Good Read Beep Frequency = High Product Reference Guide 97 LED and Beeper Indicators ENTER/EXIT PROGRAMMING MODE Good Read Beep Length Good Read Beep Length = 60 msec DEFAULT Good Read Beep Length = 80 msec Good Read Beep Length = 100 msec Good Read Beep Length = 120 msec Good Read Beep Length = 140 msec Good Read Beep Length = 160 msec Good Read Beep Length = 180 msec Good Read Beep Length = 200 msec 98 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Good Read Beep Volume Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels. Good Read Beep Volume = Beeper Off Good Read Beep Volume = Low Good Read Beep Volume = Medium DEFAULT Good Read Beep Volume = High Product Reference Guide 99 LED and Beeper Indicators ENTER/EXIT PROGRAMMING MODE Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 100ms increments. See page 313 in “References” for detailed instructions and examples for setting this feature. Select Good Read LED Duration Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 003 = Good Read LED stays on for 300 ms Indicators are dimmed during sleep. 100 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Scan Mode SCANNING FEATURES Scan Mode Selects the reader’s scan operating mode. See page 314 in “References” for descriptions. DEFAULT Scan Mode = Trigger Single Scan Mode = Trigger Hold Multiple Scan Mode = Trigger Pulse Multiple Scan Mode = Flashinga Scan Mode = Always Onb Scan Mode = Stand Modec Scan Mode = Trigger Object Sense c a. Recommended scan mode for Gryphon L for hands-free stand mode operation. b. See "Laser Features" starting on page 287 for additional laser programmable timeout options. c. Not applicable to the Gryphon L. Product Reference Guide 101 Scanning Features ENTER/EXIT PROGRAMMING MODE Stand Mode Triggered Timeout This feature specifies the time to remain in Trigger Single mode after the trigger is pulled while in Stand Mode. This timeout is only used when the Scan Mode is configured as Stand Mode. This feature is not applicable to the Gryphon L model. DEFAULT Stand Mode Triggered Timeout = 0.5 Seconds Stand Mode Triggered Timeout = 1.5 Seconds Stand Mode Triggered Timeout = 2 Seconds Stand Mode Triggered Timeout = 3 Seconds Stand Mode Triggered Timeout = 4 Seconds Stand Mode Triggered Timeout = 6 Seconds 102 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Stand Detection Stand Mode Triggered Timeout — continued Stand Mode Triggered Timeout = 8 Seconds Stand Mode Triggered Timeout = Switch back to Trigger Single on trigger pull Stand Detection Specifies the behavior of the scanner when placed in a stand that contains autorecognition hardware. This feature is not applicable to the Gryphon L. Ignore Autorecognition DEFAULT Switch to Stand Mode Switch to Always On Switch to Flashing Product Reference Guide 103 Scanning Features ENTER/EXIT PROGRAMMING MODE Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high. This feature is not applicable to the Gryphon L. Stand Mode Sensitivity = Low DEFAULT Stand Mode Sensitivity = Medium Stand Mode Sensitivity = High Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. See page 315 in “References” for descriptions of each feature Select Scanning Active Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 104 005 = Scanning is active for 5 Seconds Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Flash On Time Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.See page 316 in “References” for detailed information on setting this feature. Select Flash ON Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 10 = Flash is ON for 1 Second Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See page 317 in “References” for detailed information on setting this feature. Select Flash OFF Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 06 = Flash is OFF for 600ms 105 Scanning Features ENTER/EXIT PROGRAMMING MODE Green Spot Duration Specifies the duration of the good read pointer beam after a good read. Green Spot Duration = Disable (Green Spot is Off) DEFAULT Green Spot Duration = Short (300 msec) Green Spot Duration = Medium (500 msec) Green Spot Duration = Long (800 msec) 106 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 CODE SELECTION The reader supports the following symbologies (barcode types). Symbology-dependent options for each symbology are included in this chapter. CODE EAN/UPC on page 109 • Coupon Control • UPC-A • UPC-E • EAN 13 (Jan 13) • ISSN • EAN 8 (Jan 8) • UPC/EAN Global Settings STANDARD 2 OF 5 on page 178 INDUSTRIAL 2 OF 5 on page 184 • Code IATA DATALOGIC 2 OF 5 on page 191 CODABAR on page 197 • ABC Codabar CODE 11 on page 212 GS1 DATABAR™ OMNIDIRECTIONAL on page 221 CODE 39 on page 136 • GS1 DataBar™ Omnidirectional • Code 32 (ITAL Pharmaceutical Code) • GS1 DataBar™ Expanded • Code 39 CIP (French Pharmaceutical) • GS1 DataBar™ Limited CODE 128 on page 151 • GS1-128 CODE ISBT 128 on page 162 CODABLOCK F on page 165 INTERLEAVED 2 OF 5 (I 2 OF 5) on page 169 CODE 93 on page 229 MSI on page 237 PLESSEY on page 243 CODE 4 on page 251 CODE 5 on page 252 • Follett 2 of 5 • Interleaved 2 of 5 CIP HR Default settings are indicated at each feature/option with a green arrow. Also reference Appendix B, Standard Defaults for a listing of the most widely used set of standard factory settings. That section also provides space to record any custom settings needed or implemented for your system. To set most features: 1. Scan the ENTER/EXIT PROGRAMMING barcode at the top of applicable programming pages. 2. Scan the correct barcode to set the desired programming feature or parameter. You may need to cover unused barcodes on the page, and possibly the facing page, to ensure that the reader reads only the barcode you intend to scan. Product Reference Guide 107 Disable All Symbologies 3. If additional input parameters are needed, go to Appendix D, Keypad, and scan the appropriate characters from the keypad. Additional information about many features can be found in the “References” chapter. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 4. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING barcode to exit Programming Mode. DISABLE ALL SYMBOLOGIES Use this feature to disable all symbologies. 1. Scan the ENTER/EXIT PROGRAMMING barcode below. 2. Scan the Disable All Symbologies barcode. 3. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING barcode. ENTER/EXIT PROGRAMMING MODE Disable All Symbologies This does not disable the reading of programming labels. 108 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Coupon Control CODE EAN/UPC Coupon Control This feature is used to control the reader’s method of processing coupon labels. Coupon Control = Allow all coupon barcodes to be decoded DEFAULT Coupon Control = Enable only UPCA coupon decoding Coupon Control = Enable only GS1 DataBar™ coupon decoding Product Reference Guide 109 Code EAN/UPC ENTER/EXIT PROGRAMMING MODE UPC-A The following options apply to the UPC-A symbology. UPC-A Enable/Disable When disabled, the reader will not read UPC-A barcodes. UPC-A = Disable DEFAULT UPC-A = Enable UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A barcode data. UPC-A Check Character Transmission = Don’t Send DEFAULT UPC-A Check Character Transmission = Send 110 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Expand UPC-A to EAN-13 Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. DEFAULT UPC-A to EAN-13 = Don’t Expand UPC-A to EAN-13 = Expand UPC-A Number System Character Transmission This feature enables/disables transmission of the UPC-A number system character. UPC-A Number System Character = Do not transmit DEFAULT UPC-A Number System Character = Transmit Product Reference Guide 111 Code EAN/UPC ENTER/EXIT PROGRAMMING MODE UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as a good read. DEFAULT UPC-A Minimum Reads = 1 UPC-A Minimum Reads = 2 UPC-A Minimum Reads = 3 UPC-A Minimum Reads = 4 112 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE UPC-E Enable/Disable UPC-E The following options apply to the UPC-E symbology. UPC-E Enable/Disable When disabled, the reader will not read UPC-E barcodes. UPC-E = Disable DEFAULT UPC-E = Enable UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E barcode data. UPC-E Check Character Transmission = Don’t Send DEFAULT UPC-E Check Character Transmission = Send Product Reference Guide 113 UPC-E ENTER/EXIT PROGRAMMING MODE Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. DEFAULT UPC-E to EAN-13 = Don’t Expand UPC-E to EAN-13 = Expand Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format. DEFAULT UPC-E to UPC-A = Don’t Expand UPC-E to UPC-A = Expand 114 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE UPC-E Number System Character Transmission UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number character. UPC-E Number System Character = Do not transmit DEFAULT UPC-E Number System Character = Transmit UPC-E Minimum Reads Specifies the minimum number of consecutive times a UPC-E label must be decoded before it is accepted as a good read. UPC-E Minimum Reads = 1 DEFAULT UPC-E Minimum Reads = 2 UPC-E Minimum Reads = 3 UPC-E Minimum Reads = 4 Product Reference Guide 115 GTIN Formatting ENTER/EXIT PROGRAMMING MODE GTIN FORMATTING This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14-character format. If add-on information is present on the base label prior to the conversion taking place, the add-on information will be appended to the converted GTIN label. DEFAULT GTIN Formatting = Disable GTIN Formatting = Enable 116 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE EAN 13 Enable/Disable EAN 13 (JAN 13) The following options apply to the EAN 13 (Jan 13) symbology. EAN 13 Enable/Disable When disabled, the reader will not read EAN 13/JAN 13 barcodes. EAN 13 = Disable DEFAULT EAN 13 = Enable EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode data. EAN 13 Check Character Transmission = Don’t Send DEFAULT EAN 13 Check Character Transmission = Send Product Reference Guide 117 EAN 13 (Jan 13) ENTER/EXIT PROGRAMMING MODE EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label. EAN-13 Flag 1 Char= Don’t transmit DEFAULT EAN-13 Flag 1 Char= Transmit EAN-13 ISBN Conversion This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels. DEFAULT EAN-13 ISBN Conversion = Disable EAN-13 ISBN Conversion = Convert to ISBN 118 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE EAN 13 Minimum Reads EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read. DEFAULT EAN 13 Minimum Reads = 1 EAN 13 Minimum Reads = 2 EAN 13 Minimum Reads = 3 EAN 13 Minimum Reads = 4 Product Reference Guide 119 ISSN ENTER/EXIT PROGRAMMING MODE ISSN The following options apply to the ISSN symbology. ISSN Enable/Disable Enables/disables conversion of EAN/JAN13 Bookland labels starting with 977 to ISSN labels. DEFAULT ISSN = Disable ISSN = Enable 120 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE EAN 8 Enable/Disable EAN 8 (JAN 8) The following options apply to the EAN 8 (Jan 8) symbology. EAN 8 Enable/Disable When disabled, the reader will not read EAN 8/JAN 8 barcodes. EAN 8 = Disable DEFAULT EAN 8 = Enable EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 barcode data. EAN 8 Check Character Transmission = Don’t Send DEFAULT EAN 8 Check Character Transmission = Send Product Reference Guide 121 EAN 8 (Jan 8) ENTER/EXIT PROGRAMMING MODE Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. DEFAULT Expand EAN 8 to EAN 13 = Disable Expand EAN 8 to EAN 13 = Enable EAN 8 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label must be decoded before it is accepted as good read. DEFAULT EAN 8 Minimum Reads = 1 EAN 8 Minimum Reads = 2 EAN 8 Minimum Reads = 3 EAN 8 Minimum Reads = 4 122 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE UPC/EAN Decoding Level UPC/EAN GLOBAL SETTINGS This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description. UPC/EAN Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature. UPC/EAN Decoding Level = 1 (Conservative) DEFAULT UPC/EAN Decoding Level = 2 UPC/EAN Decoding Level = 3 UPC/EAN Decoding Level = 4 UPC/EAN Decoding Level = 5 (Aggressive) Product Reference Guide 123 UPC/EAN Global Settings ENTER/EXIT PROGRAMMING MODE UPC/EAN Correlation When correlation is enabled, the reader will combine label data from multiple scans when decoding. This will help the scanner read labels that have spots, voids and/or damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly. DEFAULT UPC/EAN Correlation = Disable UPC/EAN Correlation = Enable UPC/EAN Price Weight Check This feature enables/disables calculation and verification of price/weight check digits. DEFAULT Price Weight Check = Disabled Price Weight Check = 4-digit price-weight check Price Weight Check = 5-digit price-weight check Price Weight Check = European 4-digit price-weight check Price Weight Check = European 5-digit price-weight check 124 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE In-Store Minimum Reads In-Store Minimum Reads This feature specifies the minimum number of consecutive times an in-store label must be decoded before it is accepted as good read. In-store labels are defined as UPC-A labels with a number-system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label starting with the three characters '980'. In-Store Minimum Reads = 1 DEFAULT In-Store Minimum Reads = 2 In-Store Minimum Reads = 3 In-Store Minimum Reads = 4 Product Reference Guide 125 Add-Ons ENTER/EXIT PROGRAMMING MODE ADD-ONS Contact Customer Support for advanced programming of optional and conditional add-ons. Optional Add-ons The reader can be enabled to optionally read the following add-ons (supplementals): If a UPC/EAN base label and an add-on are both decoded, the reader will transmit the base label and add-on. If a UPC/EAN base label is decoded without an add-on, the base label will be transmitted without an add-on. Conditional add-on settings (if enabled) are considered by the reader before optional add-on settings. DEFAULT Optional Add-Ons = Disable P2 Optional Add-Ons = Enable P2 DEFAULT Optional Add-Ons = Disable P5 Optional Add-Ons = Enable P5 DEFAULT Optional Add-Ons = Disable GS1-128 Optional Add-Ons = Enable GS1-128 126 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Optional Add-On Timer Optional Add-On Timer This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see "Optional GS1-128 Add-On Timer" on page 130.) Optional Add-on Timer = 10ms Optional Add-on Timer = 20ms Optional Add-on Timer = 30ms Optional Add-on Timer = 40ms Optional Add-on Timer = 50ms Product Reference Guide 127 Add-Ons ENTER/EXIT PROGRAMMING MODE Optional Add-On Timer — cont. Optional Add-on Timer = 60ms DEFAULT Optional Add-on Timer = 70ms Optional Add-on Timer = 100ms Optional Add-on Timer = 120ms Optional Add-on Timer = 140ms Optional Add-on Timer = 160ms 128 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Optional Add-On Timer Optional Add-On Timer — cont. Optional Add-on Timer = 180ms Optional Add-on Timer = 200ms Optional Add-on Timer = 220ms Optional Add-on Timer = 240ms Optional Add-on Timer = 260ms Optional Add-on Timer = 280ms Optional Add-on Timer = 300ms Product Reference Guide 129 Add-Ons ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer This option sets the timer expiration value to read the added part after reading the linear EAN/ UPC part. For UPC/EAN add-ons other than those of that type, see "Optional Add-On Timer" on page 127. DEFAULT Optional GS1-128 Add-On Timer = Disable Optional GS1-128 Add-On Timer = 10ms Optional GS1-128 Add-On Timer = 20ms Optional GS1-128 Add-On Timer = 30ms Optional GS1-128 Add-On Timer = 40ms Optional GS1-128 Add-On Timer = 50ms 130 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer Optional GS1-128 Add-On Timer — cont. Optional GS1-128 Add-On Timer = 60ms Optional GS1-128 Add-On Timer = 70ms Optional GS1-128 Add-On Timer = 100ms Optional GS1-128 Add-On Timer = 120ms Optional GS1-128 Add-On Timer = 140ms Optional GS1-128 Add-On Timer = 160ms Product Reference Guide 131 Add-Ons ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer — cont. Optional GS1-128 Add-On Timer = 180ms Optional GS1-128 Add-On Timer = 200ms Optional GS1-128 Add-On Timer = 220ms Optional GS1-128 Add-On Timer = 240ms Optional GS1-128 Add-On Timer = 260ms Optional GS1-128 Add-On Timer = 280ms Optional GS1-128 Add-On Timer = 300ms 132 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE P2 Add-Ons Minimum Reads P2 Add-Ons Minimum Reads This feature specifies the minimum number of times a P2 add-on must be read before it is marked as valid and then combined with a base label. P2 Add-Ons Minimum Reads = 1 DEFAULT P2 Add-Ons Minimum Reads = 2 P2 Add-Ons Minimum Reads = 3 P2 Add-Ons Minimum Reads = 4 Product Reference Guide 133 Add-Ons ENTER/EXIT PROGRAMMING MODE P5 Add-Ons Minimum Reads This feature specifies the minimum number of times a P5 add-on must be read before it is marked as valid and then combined with a base label. DEFAULT P5 Add-Ons Minimum Reads = 1 P5 Add-Ons Minimum Reads = 2 P5 Add-Ons Minimum Reads = 3 P5 Add-Ons Minimum Reads = 4 134 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE GS1-128 Add-Ons Minimum Reads GS1-128 Add-Ons Minimum Reads This feature specifies the minimum number of times an GS1-128 add-on must be read before it is marked as valid and then combined with a base label. DEFAULT GS1-128 Add-Ons Minimum Reads = 1 GS1-128 Add-Ons Minimum Reads = 2 GS1-128 Add-Ons Minimum Reads = 3 GS1-128 Add-Ons Minimum Reads = 4 Product Reference Guide 135 Code 39 ENTER/EXIT PROGRAMMING MODE CODE 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable Code 39 = Disable DEFAULT Code 39 = Enable Code 39 Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Code 39 check character. When disabled, any check character in the label is treated as a data character DEFAULT Code 39 Check Character Calculation = Don’t Calculate Code 39 Check Character Calculation = Calculate Std Check Code 39 Check Character Calculation = Calculate Mod 7 Check 136 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 39 Check Character Transmission Code 39 Check Character Calculation — cont. Code 39 Check Character Calculation = Enable Italian Post Check Code 39 Check Character Calculation = Enable Daimler Chrysler Check Code 39 Check Character Transmission Enable this option to transmit the check character along with Code 39 barcode data. Code 39 Check Character Transmission = Don’t Send DEFAULT Code 39 Check Character Transmission = Send Product Reference Guide 137 Code 39 ENTER/EXIT PROGRAMMING MODE Code 39 Start/Stop Character Transmission Enable this option to enable/disable transmission of Code 39 start and stop characters. DEFAULT Code 39 Start/Stop Character Transmission = Don’t Transmit Code 39 Start/Stop Character Transmission = Transmit Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters. DEFAULT Code 39 Full ASCII = Disable Code 39 Full ASCII = Enable 138 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 39 Quiet Zones Code 39 Quiet Zones This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a barcode, typically 10 times the width of the narrowest bar or space in the label. Code 39 Quiet Zones = Quiet Zone on one side Code 39 Quiet Zones = Quiet Zones on two sides DEFAULT Code 39 Quiet Zones = Auto Code 39 Quiet Zones = Virtual Quiet Zones on two sides Code 39 Quiet Zones = Small Quiet Zones on two sides Product Reference Guide 139 Code 39 ENTER/EXIT PROGRAMMING MODE Code 39 Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read. Code 39 Minimum Reads = 1 DEFAULT Code 39 Minimum Reads = 2 Code 39 Minimum Reads = 3 Code 39 Minimum Reads = 4 140 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 39 Decoding Level Code 39 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature. This configuration item applies to Code 39 and Code 32. Code 39 Decoding Level = 1 (Conservative) Code 39 Decoding Level = 2 DEFAULT Code 39 Decoding Level = 3 Code 39 Decoding Level = 4 Code 39 Decoding Level = 5 (Aggressive) Product Reference Guide 141 Code 39 ENTER/EXIT PROGRAMMING MODE Code 39 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 39 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. DEFAULT Code 39 Length Control = Variable Length Code 39 Length Control = Fixed Length 142 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 39 Set Length 1 Code 39 Set Length 1 This feature specifies one of the barcode lengths for Code 39 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 0 to 50 characters. Table 2 provides examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 2. Code 39 Length 1 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 00 Characters 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODE 39 LENGTH 1 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Code 39 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 02 = Length 1 is 2 Characters 143 Code 39 ENTER/EXIT PROGRAMMING MODE Code 39 Set Length 2 This feature specifies one of the barcode lengths for Code 39 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Table 3 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 3. Code 39 Length 2 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 00 (Ignore This Length) 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODE 39 LENGTH 2 SETTING 4 5 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Code 39Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 144 50 = Length 2 is 50 Characters Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio Code 39 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 39 labels. Code 39 Interdigit Ratio = Disable Code 39 Interdigit Ratio = 1 Code 39 Interdigit Ratio = 2 Code 39 Interdigit Ratio = 3 DEFAULT Code 39 Interdigit Ratio = 4 Code 39 Interdigit Ratio = 5 Product Reference Guide 145 Code 39 ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio — cont. Code 39 Interdigit Ratio = 6 Code 39 Interdigit Ratio = 7 Code 39 Interdigit Ratio = 8 Code 39 Interdigit Ratio = 9 Code 39 Interdigit Ratio = 10 146 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 39 Character Correlation Code 39 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly. DEFAULT Code 39 Character Correlation = Disable Code 39 Character Correlation = Enable Code 39 Stitching This option enables/disables stitching for Code 39 labels. When parts of a Code 39 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met. Code 39 Stitching = Disable DEFAULT Code 39 Stitching = Enable Product Reference Guide 147 Code 32 (ITAL Pharmaceutical Code) ENTER/EXIT PROGRAMMING MODE CODE 32 (ITAL PHARMACEUTICAL CODE) The following options apply to the Code 32 (Italian Pharmaceutical Code) symbology. Code 32 Enable/Disable When disabled, the reader will not read Code 32 barcodes. DEFAULT Code 32 = Disable Code 32 = Enable Code 32 Feature Setting Exceptions The following features are set for Code 32 by using these Code 39 settings: "Code 39 Quiet Zones" on page 139 "Code 39 Minimum Reads" on page 140 "Code 39 Decoding Level" on page 141 "Code 39 Interdigit Ratio" on page 145 "Code 39 Character Correlation" on page 147 "Code 39 Stitching" on page 147 148 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 32 Check Char Transmission Code 32 Check Char Transmission Enable this option to transmit the check character along with Code 32 barcode data. DEFAULT Code 32 Check Character Transmission = Don’t Send Code 32 Check Character Transmission = Send Code 32 Start/Stop Character Transmission This option enables/disables transmission of Code 32 start and stop characters. DEFAULT Code 32 Start/Stop Character Transmission = Don’t Transmit Code 32 Start/Stop Character Transmission = Transmit Product Reference Guide 149 Code 39 CIP (French Pharmaceutical) ENTER/EXIT PROGRAMMING MODE CODE 39 CIP (FRENCH PHARMACEUTICAL) The following options apply to the Code 39 CIP symbology. Code 39 CIP Enable/Disable Enables/Disables ability of the reader to decode Code 39 CIP labels. DEFAULT Code 39 CIP = Disable Code 39 CIP = Enable 150 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 128 Enable/Disable CODE 128 The following options apply to the Code 128 symbology. Code 128 Enable/Disable When disabled, the reader will not read Code 128 barcodes. Code 128 = Disable DEFAULT Code 128 = Enable Expand Code 128 to Code 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels. DEFAULT Code 128 to Code 39 = Don’t Expand Code 128 to Code 39 = Expand Product Reference Guide 151 Code 128 ENTER/EXIT PROGRAMMING MODE Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 barcode data. DEFAULT Code 128 Check Character Transmission = Don’t Send Code 128 Check Character Transmission = Send Code 128 Function Character Transmission Enables/disables transmission of Code128 function characters 1, 2, 3, and 4. DEFAULT Code 128 Function Character Transmission = Don’t Send Code 128 Function Character Transmission = Send 152 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 128 Sub-Code Change Transmission Code 128 Sub-Code Change Transmission Enables/disables the transmission of “Sub-Code exchange” characters (NOT transmitted by standard decoding). DEFAULT Code 128 Sub-Code Change Transmission = Disable Code 128 Sub-Code Change Transmission = Enable Product Reference Guide 153 Code 128 ENTER/EXIT PROGRAMMING MODE Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label. Code 128 Quiet Zones = No Quiet Zones Code 128 Quiet Zones = Quiet Zone on one side Code 128 Quiet Zones = Quiet Zones on two sides DEFAULT Code 128 Quiet Zones = Auto Code 128 Quiet Zones = Virtual Quiet Zones on two sides 154 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 128 Minimum Reads Code 128 Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read. DEFAULT Code 128 Minimum Reads = 1 Code 128 Minimum Reads = 2 Code 128 Minimum Reads = 3 Code 128 Minimum Reads = 4 Product Reference Guide 155 Code 128 ENTER/EXIT PROGRAMMING MODE Code 128 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature. Code 128 Decoding Level = 1 (Conservative) Code 128 Decoding Level = 2 DEFAULT Code 128 Decoding Level = 3 Code 128 Decoding Level = 4 Code 128 Decoding Level = 5 (Aggressive) 156 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 128 Length Control Code 128 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology. See page 302 for more information.. DEFAULT Code 128 Length Control = Variable Length Code 128 Length Control = Fixed Length Product Reference Guide 157 Code 128 ENTER/EXIT PROGRAMMING MODE Code 128 Set Length 1 Specifies one of the barcode lengths for Code 128 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 80 characters. Table 4 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 4. Code 128 Length 1 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 01 Character 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODE 128 LENGTH 1 SETTING 4 5 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ 80 Characters ‘8’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Code 128 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 158 01 = Length 1 is 1 Character Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 128 Set Length 2 Code 128 Set Length 2 This feature specifies one of the barcode lengths for Code 128 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 80 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 5 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 5. Code 128 Length 2 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 00 (Ignore This Length) 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODE 128 LENGTH 2 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘0’ ‘0’ and ‘7’ ‘0’ and ‘F’ 80 Characters ‘5’ AND 0’ Scan ENTER/EXIT PROGRAMMING MODE . Select Code 128 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 80 = Length 2 is 80 Characters 159 Code 128 ENTER/EXIT PROGRAMMING MODE Code 128 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly. DEFAULT Code 128 Character Correlation = Disable Code 128 Character Correlation = Enable Code 128 Stitching This option enables/disables stitching for Code 128 labels. When parts of a Code 128 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met. Code 128 Stitching = Disable DEFAULT Code 128 Stitching = Enable 160 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE GS1-128 Enable GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS-128, GS1-128, GTIN-128, UCC-128, EAN-128.) GS1-128 Enable This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are: • Transmit GS1-128 labels in Code 128 data format. • Transmit GS1-128 labels in GS1-128 data format. • Do not transmit GS1-128 labels. GS1-128 = Transmit in Code 128 data format DEFAULT GS1-128 = Transmit in GS1-128 data format GS1-128 = Do not transmit GS1-128 labels Product Reference Guide 161 Code ISBT 128 ENTER/EXIT PROGRAMMING MODE CODE ISBT 128 The following options apply to the ISBT 128 symbology. ISBT 128 Concatenation Use this option to enable/disable ISBT128 concatenation of 2 labels. DEFAULT ISBN 128 Concatenation = Disable ISBN 128 Concatenation = Enable ISBT 128 Force Concatenation When enabled, this feature forces concatenation for ISBT. This option is only valid when ISBT 128 Concatenation is enabled . DEFAULT ISBT 128 Force Concatenation = Disable ISBT 128 Force Concatenation = Enable 162 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE ISBT 128 Concatenation Mode ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic. This option is only valid when ISBT 128 Concatenation is enabled (see page 162). DEFAULT ISBT 128 Concatenation Mode = Static ISBT 128 Concatenation Mode = Dynamic Product Reference Guide 163 Code ISBT 128 ENTER/EXIT PROGRAMMING MODE ISBT 128 Dynamic Concatenation Timeout Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode. ISBT 128 Dynamic Concatenation Timeout = 50 msec ISBT 128 Dynamic Concatenation Timeout = 100 msec DEFAULT ISBT 128 Dynamic Concatenation Timeout = 200 msec ISBT 128 Dynamic Concatenation Timeout = 500 msec ISBT 128 Dynamic Concatenation Timeout = 750 msec ISBT 128 Dynamic Concatenation Timeout = 1 second ISBT 128 Advanced Concatenation Options To set up pairs of label types for concatenation, use the Datalogic Aladdin configuration application or contact Datalogic Technical Support, as described on page 10. 164 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Codablock F Enable/Disable CODABLOCK F The following options apply to the Codablock F symbology. Codablock F Enable/Disable Enables/Disables ability of reader to decode Codablock F labels. DEFAULT Codablock F = Disable Codablock F = Enable Codablock F EAN Enable/Disable Enables/Disables the Codablock F EAN subtype (code with FNC1 in the first position).. DEFAULT Codablock F EAN = Disable Codablock F EAN = Enable Product Reference Guide 165 Codablock F ENTER/EXIT PROGRAMMING MODE Codablock F AIM Check Specifies if Check Digit calculation algorithm is AIM compliant or not. Codablock F AIM Check = Disable DEFAULT Codablock F AIM Check = Enable Check C Codablock F Length Control This feature specifies either variable length decoding or fixed length decoding for the Codablock F symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. DEFAULT Codablock F Length Control = Variable Length Codablock F = Fixed Length 166 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Codablock F Set Length 1 Codablock F Set Length 1 Specifies one of the barcode lengths for Codablock F Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. Characters can be set from 03 to 255 characters. Table 6 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 6. CODABLOCK F Length 1 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 03 Characters 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODABLOCK F LENGTH 1 SETTING 4 Scan Three Characters From ‘0’, ‘0’ and ‘3’ Appendix D, Keypad 5 ‘0’, ‘0’ and ‘7’ ‘0’,‘1’ and ‘5’ 50 Characters ‘0’,‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Codablock F Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 03 = Length 1 is 3 Characters 167 Codablock F ENTER/EXIT PROGRAMMING MODE Codablock F Set Length 2 This feature specifies one of the barcode lengths for Codablock F Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Table 7 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 7. CODABLOCK F Length 2 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 00 (Ignore This Length) 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODABLOCK F LENGTH 2 SETTING 4 Scan Three Characters From Appendix D, Keypad 5 ‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘7’ ‘0’,‘1’ and ‘5’ 50 Characters ‘0’,‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Codablock F Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 168 100 = Length 2 is 100 Characters Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE I 2 of 5 Enable/Disable INTERLEAVED 2 OF 5 (I 2 OF 5) The following options apply to the I 2 of 5 symbology. I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 barcodes. DEFAULT I 2 of 5 = Disable I 2 of 5 = Enable I 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional I 2 of 5 check character. DEFAULT I 2 of 5 Check Character Calculation = Disable I 2 of 5 Check Character Calculation = Check Standard (Modulo 10) I 2 of 5 Check Character Calculation = Check German Parcel Product Reference Guide 169 Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE I 2 of 5 Check Character Calculation - cont. I 2 of 5 Check Character Calculation = Check DHL I 2 of 5 Check Character Calculation = Check Daimler Chrysler I 2 of 5 Check Character Calculation = Check Bosch I 2 of 5 Check Character Calculation = Italian Post I 2 of 5 Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 barcode data. I 2 of 5 Check Character Transmission = Don’t Send DEFAULT I 2 of 5 Check Character Transmission = Send 170 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE I 2 of 5 Minimum Reads I 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read. I 2 of 5 Minimum Reads = 1 DEFAULT I 2 of 5 Minimum Reads = 2 I 2 of 5 Minimum Reads = 3 I 2 of 5 Minimum Reads = 4 Product Reference Guide 171 Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE 2 of 5 Decoding Level This configuration item applies to Interleaved 2 of 5, Datalogic 2 of 5 and Standard 2 of 5. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature. 2 of 5 Decoding Level = 1 (Conservative) 2 of 5 Decoding Level = 2 DEFAULT 2 of 5 Decoding Level = 3 2 of 5 Decoding Level = 4 2 of 5 Decoding Level = 5 (Aggressive) 172 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE I 2 of 5 Length Control I 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. DEFAULT I 2 of 5 Length Control = Variable Length I 2 of 5 Length Control = Fixed Length Product Reference Guide 173 Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE I 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for I 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters in increments of two. Table 8 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 8. I 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Characters 6 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 02 06 14 50 ‘1’ and ‘4’ ‘5’ AND ‘0’ 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT I 2 of 5 LENGTH 1 SETTING 5 6 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘2’ ‘0’ and ‘6’ Scan ENTER/EXIT PROGRAMMING MODE Select I 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 174 06 = Length 1 is 6 Characters Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE I 2 of 5 Set Length 2 I 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for I 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 9 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 9. I 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Ignore This Length 4 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 00 04 14 50 ‘1’ and ‘4’ ‘5’ AND ‘0’ 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT I 2 OF 5 LENGTH 2 SETTING 5 Scan Two Characters From Appendix D, Keypad 6 ‘0’ and ‘0’ ‘0’ and ‘4’ Scan ENTER/EXIT PROGRAMMING MODE Select I 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 50 = Length 2 is 50 Characters 175 Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE I 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly. DEFAULT I 2 of 5 Character Correlation = Disable I 2 of 5 Character Correlation = Enable I 2 of 5 Stitching This option enables/disables stitching for I 2 of 5 labels. When parts of a I 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met. DEFAULT I 2 of 5 Stitching = Disable I 2 of 5 Stitching = Enable 176 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Follett 2 of 5 Enable/Disable FOLLETT 2 OF 5 The following options apply to the Follett 2 of 5 symbology. Follett 2 of 5 Enable/Disable Enables/Disables ability of imager to decode Follett 2 of 5 labels. DEFAULT Follett 2 of 5 = Disable Follett 2 of 5 = Enable INTERLEAVED 2 OF 5 CIP HR The following options apply to the Interleaved 2 of 5 CIP HR symbology. Interleaved 2 of 5 CIP HR Enable/Disable Enables/Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels. DEFAULT Interleaved 2 of 5 CIP HR = Disable Interleaved 2 of 5 CIP HR = Enable Product Reference Guide 177 Standard 2 of 5 ENTER/EXIT PROGRAMMING MODE STANDARD 2 OF 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 barcodes. DEFAULT Standard 2 of 5 = Disable Standard 2 of 5 = Enable Standard 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Standard 2 of 5 check character. DEFAULT Standard 2 of 5 Check Character Calculation = Disable Standard 2 of 5 Check Character Calculation = Enable 178 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Check Character Transmission Standard 2 of 5 Check Character Transmission This feature enables/disables transmission of an optional Standard 2 of 5 check character. Standard 2 of 5 Check Character Transmission = Don’t Send DEFAULT Standard 2 of 5 Check Character Transmission = Send Standard 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read. Standard 2 of 5 Minimum Reads = 1 DEFAULT Standard 2 of 5 Minimum Reads = 2 Standard 2 of 5 Minimum Reads = 3 Standard 2 of 5 Minimum Reads = 4 Product Reference Guide 179 Standard 2 of 5 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Decoding Level The Standard 2 of 5 Decoding Level feature is set using "2 of 5 Decoding Level" on page 172. Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. DEFAULT Standard 2 of 5 Length Control = Variable Length Standard 2 of 5 Length Control = Fixed Length 180 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Set Length 1 Standard 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 1 to 50 characters. Table 10 provides some examples for setting Length 1. See page 302 if you want detailed instructions on setting this feature. Table 10. Standard 2 of 5 Length 1 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 01 Character 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 08 = Length 1 is 8 Characters 181 Standard 2 of 5 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 11 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 11. Standard 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting (pad with leading zeroes) 00 (Ignore This Length) 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT STANDARD 2 OF 5 LENGTH 2 SETTING 4 5 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 182 50 = Length 2 is 50 Characters Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Character Correlation Standard 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly. DEFAULT Standard 2 of 5 Character Correlation = Disable Standard 2 of 5 Character Correlation = Enable Standard 2 of 5 Stitching This option enables/disables stitching for Standard 2 of 5 labels. When parts of a Standard 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met. DEFAULT Standard 2 of 5 Stitching = Disable Standard 2 of 5 Stitching = Enable Product Reference Guide 183 Industrial 2 of 5 ENTER/EXIT PROGRAMMING MODE INDUSTRIAL 2 OF 5 The following options apply to the Industrial 2 of 5 symbology. Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode Industrial 2 of 5 labels. DEFAULT Industrial 2 of 5 = Disable Industrial 2 of 5 = Enable Industrial 2 of 5 Check Character Calculation Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character. DEFAULT Industrial 2 of 5 Check Character Calculation = Disable Industrial 2 of 5 Check Character Calculation = Enable 184 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Check Character Transmission Industrial 2 of 5 Check Character Transmission Enables/disables transmission of an Industrial 2 of 5 check character. Industrial 2 of 5 Check Character Transmission = Disable DEFAULT Industrial 2 of 5 Check Character Transmission = Enable Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. DEFAULT Industrial 2 of 5 Length Control = Variable Length Industrial 2 of 5 = Fixed Length Product Reference Guide 185 Industrial 2 of 5 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 0 to 50 characters. Table 12 provides some examples for setting Length 1. See page 302 if you want detailed instructions on setting this feature. Table 12. Industrial 2 of 5 Length 1 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 00 Characters 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 1 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Industrial 2 of 5 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 186 01 = Length 1 is 1 Character Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Set Length 2 Industrial 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 13 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 13. Industrial 2 of 5 Length 2 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 00 (Ignore This Length) 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING 4 Scan Two Characters From ‘0’ and ‘0’ Appendix D, Keypad 5 ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Industrial 2 of5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 50 = Length 2 is 50 Characters 187 Industrial 2 of 5 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Industrial 2 of 5 label must be decoded before it is accepted as good read. DEFAULT Industrial 2 of 5 Minimum Reads = 1 Industrial 2 of 5 Minimum Reads = 2 Industrial 2 of 5 Minimum Reads = 3 Industrial 2 of 5 Minimum Reads = 4 Industrial 2 of 5 Stitching Enables/disables fixed length stitching for Industrial 2 of 5. DEFAULT Industrial 2 of 5 Stitching = Disable Industrial 2 of 5 Stitching = Enable 188 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Character Correlation Industrial 2 of 5 Character Correlation Enable/disables character correlation for Industrial 2 of 5. DEFAULT Industrial 2 of 5 Character Correlation = Disable Industrial 2 of 5 Character Correlation = Enable Product Reference Guide 189 Code IATA ENTER/EXIT PROGRAMMING MODE CODE IATA The following options apply to the IATA symbology. IATA Enable/Disable Enables/Disables the ability of the reader to decode IATA labels. DEFAULT IATA = Disable IATA = Enable IATA Check Character Transmission Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character. IATA Check Character Transmission = Disable DEFAULT IATA Check Character Transmission = Enable 190 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Enable/Disable DATALOGIC 2 OF 5 The following options apply to the Datalogic 2 of 5 symbology. Datalogic 2 of 5 Enable/Disable When disabled, the reader will not read Datalogic 2 of 5 barcodes. DEFAULT Datalogic 2 of 5 = Disable Datalogic 2 of 5 = Enable Datalogic 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Datalogic 2 of 5 check character. DEFAULT Datalogic 2 of 5 Check Character Calculation = Disable Datalogic 2 of 5 Check Character Calculation = Enable Product Reference Guide 191 Datalogic 2 of 5 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Datalogic 2 of 5 label must be decoded before it is accepted as good read. I 2 of 5 Minimum Reads = 1 DEFAULT I 2 of 5 Minimum Reads = 2 I 2 of 5 Minimum Reads = 3 I 2 of 5 Minimum Reads = 4 Datalogic 2 of 5 Decoding Level The Datalogic 2 of 5 Decoding Level feature is set using "2 of 5 Decoding Level" on page 172. 192 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Length Control Datalogic 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Datalogic 2 of 5 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. DEFAULT Datalogic 2 of 5 Length Control = Variable Length Datalogic 2 of 5 Length Control = Fixed Length Product Reference Guide 193 Datalogic 2 of 5 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Datalogic 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters in increments of two. Table 14 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 14. Datalogic 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Characters 6 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 02 06 14 50 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT Datalogic 2 of 5 LENGTH 1 SETTING 5 6 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘2’ ‘0’ and ‘6’ ‘1’ and ‘4’ ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 194 06 = Length 1 is 6 Characters Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Set Length 2 Datalogic 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Datalogic 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 15 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 15. Datalogic 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Ignore This Length 4 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 00 04 14 50 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT DATALOGIC 2 OF 5 LENGTH 2 SETTING 5 Scan Two Characters From Appendix D, Keypad 6 ‘0’ and ‘0’ ‘0’ and ‘4’ ‘1’ and ‘4’ ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 50 = Length 2 is 50 Characters 195 Datalogic 2 of 5 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly. DEFAULT I 2 of 5 Character Correlation = Disable I 2 of 5 Character Correlation = Enable Datalogic 2 of 5 Stitching This option enables/disables stitching for Datalogic 2 of 5 labels. When parts of a Datalogic 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met. DEFAULT Datalogic 2 of 5 Stitching = Disable Datalogic 2 of 5 Stitching = Enable 196 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Codabar Enable/Disable CODABAR The following options apply to the Codabar symbology. Codabar Enable/Disable When disabled, the reader will not read Codabar barcodes. DEFAULT Codabar = Disable Codabar = Enable Codabar Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Codabar check character. When disabled, any check character in the label is treated as a data character DEFAULT Codabar Check Character Calculation = Don’t Calculate Codabar Check Character Calculation = Enable AIM standard check char. Codabar Check Character Calculation = Enable Modulo 10 check char. Product Reference Guide 197 Codabar ENTER/EXIT PROGRAMMING MODE Codabar Check Character Transmission Enable this option to transmit the check character along with Codabar barcode data. Codabar Check Character Transmission = Don’t Send DEFAULT Codabar Check Character Transmission = Send Codabar Start/Stop Character Transmission Enable this option to enable/disable transmission of Codabar start and stop characters. Codabar Start/Stop Character Transmission = Don’t Transmit DEFAULT Codabar Start/Stop Character Transmission = Transmit 198 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Codabar Start/Stop Character Set Codabar Start/Stop Character Set This option specifies the format of transmitted Codabar start/stop characters. Codabar Check Character Set = ABCD/TN*E Codabar Check Character Set = ABCD/ABCD Codabar Check Character Set = abcd/tn*e DEFAULT Codabar Check Character Set = abcd/abcd Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match. DEFAULT Codabar Start/Stop Character Match = Don’t Require Match Codabar Start/Stop Character Match = Require Match Product Reference Guide 199 Codabar ENTER/EXIT PROGRAMMING MODE Codabar Quiet Zones Specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label. Codabar Quiet Zones = Quiet Zone on one side Codabar Quiet Zones = Quiet Zones on two sides DEFAULT Codabar Quiet Zones = Auto Codabar Quiet Zones = Virtual Quiet Zones on two sides Codabar Quiet Zones = Small Quiet Zones on two sides 200 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Codabar Minimum Reads Codabar Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read. Codabar Minimum Reads = 1 DEFAULT Codabar Minimum Reads = 2 Codabar Minimum Reads = 3 Codabar Minimum Reads = 4 Product Reference Guide 201 Codabar ENTER/EXIT PROGRAMMING MODE Codabar Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative, depending on a particular customer’s needs. See page 302 for more information on this feature. Codabar Decoding Level = 1 (Conservative) Codabar Decoding Level = 2 DEFAULT Codabar Decoding Level = 3 Codabar Decoding Level = 4 Codabar Decoding Level = 5 202 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Codabar Length Control Codabar Length Control This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. DEFAULT Codabar Length Control = Variable Length Codabar Length Control = Fixed Length Product Reference Guide 203 Codabar ENTER/EXIT PROGRAMMING MODE Codabar Set Length 1 This feature specifies one of the barcode lengths for Codabar Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. Table 16 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 16. Codabar Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting (and pad with leading zeroes) 03 Characters 09 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODABAR LENGTH 1 SETTING 4 5 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘3’ ‘0’ and ‘9’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Codabar Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 204 03 = Length 1 is 3 Characters Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Codabar Set Length 2 Codabar Set Length 2 This feature specifies one of the barcode lengths for Codabar Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 17 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 17. Codabar Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting (and pad with leading zeroes) 00 Ignore This Length 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODABAR LENGTH 2 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Codabar Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 50 = Length 2 is 50 Characters 205 Codabar ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Codabar labels. Codabar Interdigit Ratio = Disable Codabar Interdigit Ratio = 1 Codabar Interdigit Ratio = 2 Codabar Interdigit Ratio = 3 DEFAULT Codabar Interdigit Ratio = 4 Codabar Interdigit Ratio = 5 206 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio Codabar Interdigit Ratio — cont. Codabar Interdigit Ratio = 6 Codabar Interdigit Ratio = 7 Codabar Interdigit Ratio = 8 Codabar Interdigit Ratio = 9 Codabar Interdigit Ratio = 10 Product Reference Guide 207 Codabar ENTER/EXIT PROGRAMMING MODE Codabar Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly. DEFAULT Codabar Character Correlation = Disable Codabar Character Correlation = Enable Codabar Stitching This option enables/disables stitching for Codabar labels. When parts of a Codabar barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met. DEFAULT Codabar Stitching = Disable Codabar Stitching = Enable 208 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE ABC Codabar Enable/Disable ABC CODABAR The following options apply to the ABC Codabar symbology. ABC Codabar Enable/Disable Enables/Disables ability of reader to decode ABC Codabar labels. DEFAULT ABC Codabar = Disable ABC Codabar = Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic. DEFAULT ABC Codabar Concatenation Mode = Static ABC Codabar Concatenation Mode = Dynamic Product Reference Guide 209 ABC Codabar ENTER/EXIT PROGRAMMING MODE ABC Codabar Dynamic Concatenation Timeout Specifies the timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Concatenation Mode. ABC Codabar Dynamic Concatenation Timeout = 50 msec ABC Codabar Dynamic Concatenation Timeout = 100 msec DEFAULT ABC Codabar Dynamic Concatenation Timeout = 200 msec ABC Codabar Dynamic Concatenation Timeout = 500 msec ABC Codabar Dynamic Concatenation Timeout = 750 msec ABC Codabar Dynamic Concatenation Timeout = 1 Second 210 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE ABC Codabar Force Concatenation ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated. DEFAULT ABC Codabar Force Concatenation = Disable ABC Codabar Force Concatenation = Enable Product Reference Guide 211 Code 11 ENTER/EXIT PROGRAMMING MODE CODE 11 The following options apply to the Code 11 symbology. Code 11 Enable/Disable When disabled, the reader will not read Code 11 barcodes. DEFAULT Code 11 = Disable Code 11 = Enable Code 11 Check Character Calculation This option enables/disables calculation and verification of optional Code 11 check character. Code 11 Check Character Calculation = Disable Code 11 Check Character Calculation = Check C Code 11 Check Character Calculation = Check K DEFAULT Code 11 Check Character Calculation = Check C and K 212 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 11 Check Character Transmission Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check character. Code 11 Check Character Transmission = Don’t Send DEFAULT Code 11 Check Character Transmission = Send Code 11 Minimum Reads This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read. Code 11 Minimum Reads = 1 DEFAULT Code 11 Minimum Reads = 2 Code 11 Minimum Reads = 3 Code 11 Minimum Reads = 4 Product Reference Guide 213 Code 11 ENTER/EXIT PROGRAMMING MODE Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. DEFAULT Code 11 Length Control = Variable Length Code 11 Length Control = Fixed Length 214 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 11 Set Length 1 Code 11 Set Length 1 This feature specifies one of the barcode lengths for Code 11 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. Table 18 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 18. Code 11 Length 1 Setting Examples STEP ACTION 1 Desired Setting (pad with leading zeroes) EXAMPLES 02 Characters 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODE 11 LENGTH 1 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘2’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Code 11 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 04 = Length 1 is 4 Characters 215 Code 11 ENTER/EXIT PROGRAMMING MODE Code 11 Set Length 2 This feature specifies one of the barcode lengths for Code 11 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 19 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 19. Code 11 Length 2 Setting Examples STEP ACTION 1 Desired Setting (pad with leading zeroes) EXAMPLES 00 (Ignore This Length) 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODE 11 LENGTH 2 SETTING 4 5 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘0’ ‘0’ and ‘7’ ‘0’ and ‘F’ 50 Characters ‘3’ AND 2’ Scan ENTER/EXIT PROGRAMMING MODE Select Code 11 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 216 50 = Length 2 is 50 Characters Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio Code 11 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 11 labels. Code 11 Interdigit Ratio = Disable Code 11 Interdigit Ratio = 1 Code 11 Interdigit Ratio = 2 Code11 Interdigit Ratio = 3 DEFAULT Code 11 Interdigit Ratio = 4 Code 11 Interdigit Ratio = 5 Product Reference Guide 217 Code 11 ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio — cont. Code 11 Interdigit Ratio = 6 Code 11 Interdigit Ratio = 7 Code 11 Interdigit Ratio = 8 Code 11 Interdigit Ratio = 9 Code 11 Interdigit Ratio = 10 218 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 11 Decoding Level Code 11 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature. Codabar Decoding Level = 1 (Conservative) Codabar Decoding Level = 2 DEFAULT Codabar Decoding Level = 3 Codabar Decoding Level = 4 Codabar Decoding Level = 5 (Aggressive) Product Reference Guide 219 Code 11 ENTER/EXIT PROGRAMMING MODE Code 11 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly. DEFAULT Code 11 Character Correlation = Disable Code 11 Character Correlation = Enable Code 11 Stitching This option enables/disables stitching for Code 11 labels. When parts of a Code 11 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met. DEFAULT Code 11 Stitching = Disable Code 11 Stitching = Enable 220 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Omnidirectional Enable/Disable GS1 DATABAR™ OMNIDIRECTIONAL The following options apply to the GS1 DataBar™ Omnidirectional (formerly RSS-14) symbology. GS1 DataBar™ Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar™ Omnidirectional barcodes. DEFAULT GS1 DataBar™ Omnidirectional = Disable GS1 DataBar™ Omnidirectional = Enable GS1 DataBar™ Omnidirectional GS1-128 Emulation When enabled, GS1 DataBar™ Omnidirectional barcodes will be translated to the GS1-128 label data format. DEFAULT GS1 DataBar™ Omnidirectional GS1-128 Emulation = Disable GS1 DataBar™ Omnidirectional GS1-128 Emulation = Enable Product Reference Guide 221 GS1 DataBar™ Omnidirectional ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Omnidirectional Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Omnidirectional label must be decoded before it is accepted as good read. DEFAULT GS1 DataBar™ Omnidirectional Minimum Reads = 1 GS1 DataBar™ Omnidirectional Minimum Reads = 2 GS1 DataBar™ Omnidirectional Minimum Reads = 3 GS1 DataBar™ Omnidirectional Minimum Reads = 4 222 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Expanded Enable/Disable GS1 DATABAR™ EXPANDED The following options apply to the GS1 DataBar™ Expanded (formerly RSS Expanded) symbology. GS1 DataBar™ Expanded Enable/Disable When disabled, the reader will not read GS1 DataBar™ Expanded barcodes. DEFAULT GS1 DataBar™ Expanded = Disable GS1 DataBar™ Expanded = Enable GS1 DataBar™ Expanded GS1-128 Emulation When enabled, GS1 DataBar™ Expanded barcodes will be translated to the GS1-128 label data format. DEFAULT GS1 DataBar™ Expanded GS1-128 Emulation = Disable GS1 DataBar™ Expanded GS1-128 Emulation = Enable Product Reference Guide 223 GS1 DataBar™ Expanded ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Expanded Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Expanded label must be decoded before it is accepted as good read. DEFAULT GS1 DataBar™ Expanded Minimum Reads = 1 GS1 DataBar™ Expanded Minimum Reads = 2 GS1 DataBar™ Expanded Minimum Reads = 3 GS1 DataBar™ Expanded Minimum Reads = 4 GS1 DataBar™ Expanded Length Control This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar™ Expanded symbology. Variable Length. For variable-length decoding, a minimum length may be set. Fixed Length. For fixed-length decoding, two different lengths may be set. DEFAULT GS1 DataBar™ Expanded Length Control = Variable Length GS1 DataBar™ Expanded Length Control = Fixed Length 224 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Expanded Set Length 1 GS1 DataBar™ Expanded Set Length 1 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. Table 20 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 20. GS1 DataBar™ Expanded Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 52 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT GS1 DataBar™ EXPANDED LENGTH 1SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘1’ ‘0’ and ‘7’ ‘5’ and ‘2’ 74 Characters ‘7’ AND ‘4’ Scan ENTER/EXIT PROGRAMMING MODE Select GS1 DataBar™ Expanded Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 01 = Length 1 is 1 Character 225 GS1 DataBar™ Expanded ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Expanded Set Length 2 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 21 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 21. GS1 DataBar™ Expanded Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 (ignore second length) 07 Characters 52 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT GS1 DataBar™ EXPANDED LENGTH 2 SETTING 4 5 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘0’ ‘0’ and ‘7’ ‘5’ and ‘2’ 74 Characters ‘7’ and ‘4’ Scan ENTER/EXIT PROGRAMMING MODE Select GS1 DataBar™ Expanded Set Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 226 74 = Length 2 is 74 Characters Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Limited Enable/Disable GS1 DATABAR™ LIMITED The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology. GS1 DataBar™ Limited Enable/Disable When disabled, the reader will not read GS1 DataBar™ Limited barcodes. DEFAULT GS1 DataBar™ Limited = Disable GS1 DataBar™ Limited = Enable GS1 DataBar™ Limited GS1-128 Emulation When enabled, GS1 DataBar™ Limited barcodes will be translated to the GS1-128 label data format. DEFAULT GS1 DataBar™ Limited GS1-128 Emulation = Disable GS1 DataBar™ Limited GS1-128 Emulation = Enable Product Reference Guide 227 GS1 DataBar™ Limited ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Limited Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Limited label must be decoded before it is accepted as good read. DEFAULT GS1 DataBar™ Limited Minimum Reads = 1 GS1 DataBar™ Limited Minimum Reads = 2 GS1 DataBar™ Limited Minimum Reads = 3 GS1 DataBar™ Limited Minimum Reads = 4 228 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 93 Enable/Disable CODE 93 The following options apply to the Code 93 symbology. Code 93 Enable/Disable Enables/Disables ability of reader to decode Code 93 labels. DEFAULT Code 93 = Disable Code 93 = Enable Code 93 Check Character Calculation Enables/disables calculation and verification of an optional Code 93 check character. Code 93 Check Character Calculation = Disable Code 93 Check Character Calculation = Enable Check C Code 93 Check Character Calculation = Enable Check K DEFAULT Code 93 Check Character Calculation = Enable Check C and K Product Reference Guide 229 Code 93 ENTER/EXIT PROGRAMMING MODE Code 93 Check Character Transmission Enables/disables transmission of an optional Code 93 check character. DEFAULT Code 93 Check Character Transmission = Disable Code 93 Check Character Transmission = Enable Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. DEFAULT Code 93 Length Control = Variable Length Code 93 = Fixed Length 230 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 93 Set Length 1 Code 93 Set Length 1 Specifies one of the barcode lengths for Code 93 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 22 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 22. Code 93 Length 1 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 01 Characters 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODE 93 LENGTH 1 SETTING 4 Scan Two Characters From ‘0’ and ‘1’ Appendix D, Keypad 5 ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Code 93 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 01 = Length 1 is 1 Character 231 Code 93 ENTER/EXIT PROGRAMMING MODE Code 93 Set Length 2 This feature specifies one of the barcode lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 23 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 23. CODE 93 Length 2 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 00 (Ignore This Length) 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODE 93 LENGTH 2 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Code 93 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 232 50 = Length 2 is 50 Characters Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 93 Minimum Reads Code 93 Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read. DEFAULT Code 93 Minimum Reads = 1 Code 93 Minimum Reads = 2 Code 93 Minimum Reads = 3 Code 93 Minimum Reads = 4 Product Reference Guide 233 Code 93 ENTER/EXIT PROGRAMMING MODE Code 93 Decoding Level Specifies the decoding level for Code 93. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature. Code 93 Decoding Level = Disable Code 93 Decoding Level = 1 (Conservative) Code 93 Decoding Level = 2 DEFAULT Code 93 Decoding Level = 3 Code 93 Decoding Level = 4 Code 93 Decoding Level = 5 (Aggressive) 234 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 93 Quiet Zones Code 93 Quiet Zones Enables/disables quiet zones for Code 93. Code 93 Quiet Zones = No Quiet Zones Code 93 Quiet Zones = Quiet Zone on one side Code 93 Quiet Zones = Quiet Zones on two sides DEFAULT Code 93 Quiet Zones = Auto Code 93 Quiet Zones = Virtual Quiet Zones on two sides Product Reference Guide 235 Code 93 ENTER/EXIT PROGRAMMING MODE Code 93 Stitching Disable/enable fixed or variable length stitching for Code 93. Code 93 Stitching = Disable DEFAULT Code 93 Stitching = Enable Code 93 Character Correlation Enables/disables Character Correlation for Code 93. DEFAULT Code 93 Character Correlation = Disable Code 93 Character Correlation = Enable 236 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE MSI Enable/Disable MSI The following options apply to the MSI symbology. MSI Enable/Disable Enables/Disables ability of reader to decode MSI labels. DEFAULT MSI = Disable MSI = Enable MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check character. MSI Check Character Calculation = Disable DEFAULT MSI Check Character Calculation = Enable Mod10 MSI Check Character Calculation = Enable Mod11/10 MSI Check Character Calculation = Enable Mod10/10 Product Reference Guide 237 MSI ENTER/EXIT PROGRAMMING MODE MSI Check Character Transmission Enables/disables transmission of an MSI check character. MSI Check Character Transmission = Disable DEFAULT MSI Check Character Transmission = Enable MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. DEFAULT MSI Length Control = Variable Length MSI = Fixed Length 238 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE MSI Set Length 1 MSI Set Length 1 This feature specifies one of the barcode lengths for MSI Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 24 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 24. MSI Length 1 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 01 Characters 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT MSI LENGTH 1 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select MSI Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 01 = Length 1 is 1 Character 239 MSI ENTER/EXIT PROGRAMMING MODE MSI Set Length 2 This feature specifies one of the barcode lengths for MSI Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 25 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 25. MSI Length 2 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 00 (Ignore This Length) 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT MSI LENGTH 2 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select MSI Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 240 50 = Length 2 is 50 Characters Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE MSI Minimum Reads MSI Minimum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read. MSI Minimum Reads = 1 MSI Minimum Reads = 2 MSI Minimum Reads = 3 DEFAULT MSI Minimum Reads = 4 Product Reference Guide 241 MSI ENTER/EXIT PROGRAMMING MODE MSI Decoding Level Specifies the decoding level for MSI. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature. MSI Decoding Level = Disable MSI Decoding Level = 1 (conservative) MSI Decoding Level = 2 DEFAULT MSI Decoding Level = 3 MSI Decoding Level = 4 MSI Decoding Level = 5 (aggressive) 242 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Plessey Enable/Disable PLESSEY The following options apply to the Plessey symbology. Plessey Enable/Disable Enables/Disables ability of reader to decode Plessey labels. DEFAULT Plessey = Disable Plessey = Enable Product Reference Guide 243 Plessey ENTER/EXIT PROGRAMMING MODE Plessey Check Character Calculation Enables/Disables calculation and verification of an optional Plessey check character. Plessey Check Character Calculation = Disable DEFAULT Plessey Check Character Calculation = Enable Plessey std. check char. verification Plessey Check Character Calculation = Enable Anker check char. verification Plessey Check Character Calculation = Enable Plessey std. and Anker check char verification Plessey Check Character Transmission Enables/disables transmission of an MSI check character. Plessey Check Character Transmission = Disable DEFAULT Plessey Check Character Transmission = Enable 244 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Plessey Length Control Plessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. DEFAULT Plessey Length Control = Variable Length Plessey = Fixed Length Product Reference Guide 245 Plessey ENTER/EXIT PROGRAMMING MODE Plessey Set Length 1 This feature specifies one of the barcode lengths for Plessey Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 26 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 26. Plessey Length 1 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 01 Characters 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT Plessey LENGTH 1 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Plessey Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 246 01 = Length 1 is 1 Character Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Plessey Set Length 2 Plessey Set Length 2 This feature specifies one of the barcode lengths for Plessey Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 27 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 27. Plessey Length 2 Setting Examples STEP ACTION 1 Desired Setting EXAMPLES 00 (Ignore This Length) 07 Characters 15 Characters 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT PLESSEY LENGTH 2 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 ‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ 50 Characters ‘5’ AND ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Select Plessey Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 50 = Length 2 is 50 Characters 247 Plessey ENTER/EXIT PROGRAMMING MODE Plessey Minimum Reads This feature specifies the minimum number of consecutive times a Plessey label must be decoded before it is accepted as good read. Plessey Minimum Reads = 1 Plessey Minimum Reads = 2 Plessey Minimum Reads = 3 DEFAULT Plessey Minimum Reads = 4 248 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Plessey Decoding Level Plessey Decoding Level Specifies the decoding level for Plessey. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature. Plessey Decoding Level = Disable Plessey Decoding Level = 1 (conservative) Plessey Decoding Level = 2 DEFAULT Plessey Decoding Level = 3 Plessey Decoding Level = 4 Plessey Decoding Level = 5 (aggressive) Product Reference Guide 249 Plessey ENTER/EXIT PROGRAMMING MODE Plessey Stitching Enables/disables fixed length stitching for Plessey. DEFAULT Plessey Stitching = Disable Plessey Stitching = Enable Plessey Character Correlation Enables/disables Character Correlation for Plessey. DEFAULT Plessey Character Correlation = Disable Plessey Character Correlation = Enable 250 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 4 Enable/Disable CODE 4 The following options apply to the Code 4 symbology. Code 4 Enable/Disable Enables/Disables ability of imager to decode Code 4 labels. DEFAULT Code 4 = Disable Code 4 = Enable Code 4 Check Character Transmission This feature enables/disables transmission of an optional Code 4 check character. Code 4 Check Character Transmission = Don’t Send DEFAULT Code 4 Check Character Transmission = Send Product Reference Guide 251 Code 5 ENTER/EXIT PROGRAMMING MODE Code 4 Hex to Decimal Conversion This feature enables/disables the conversion of hexidecimal label data to decimal label data. Code 4 Hex to Decimal Conversion = Disable DEFAULT Code 4 Hex to Decimal Conversion = Enable CODE 5 The following options apply to the Code 5 symbology. Code 5 Enable/Disable Enables/Disables ability of imager to decode Code 5 labels. DEFAULT Code 5 = Disable Code 5 = Enable 252 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 5 Check Character Transmission Code 5 Check Character Transmission This feature enables/disables transmission of an optional Code 5 check character. Code 5 Check Character Transmission = Don’t Send DEFAULT Code 5 Check Character Transmission = Send Code 5 Hex to Decimal Conversion This feature enables/disables the conversion of hexidecimal label data to decimal label data. Code 5 Hex to Decimal Conversion = Disable DEFAULT Code 5 Hex to Decimal Conversion = Enable Product Reference Guide 253 Code 4 and Code 5 Common Configuration Items ENTER/EXIT PROGRAMMING MODE CODE 4 AND CODE 5 COMMON CONFIGURATION ITEMS The following options apply to both Code 4 and Code 5 symbologies. Code 4 and 5 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 291 for more information on this feature. This configuration item applies to Code 4 and Code 5. Code 4 and Code 5 Decoding Level = 1 (conservative) Code 4 and Code 5 Decoding Level = 2 DEFAULT Code 4 and Code 5 Decoding Level = 3 Code 4 and Code 5 Decoding Level = 4 Code 4 and Code 5 Decoding Level = 5 (aggressive) 254 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Code 4 and Code 5 Minimum Reads Code 4 and Code 5 Minimum Reads This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read. DEFAULT Code 4 or Code 5 Minimum Reads = 1 Code 4 or Code 5 Minimum Reads = 2 Code 4 or Code 5 Minimum Reads = 3 Code 4 or Code 5 Minimum Reads = 4 Product Reference Guide 255 Code 4 and Code 5 Common Configuration Items ENTER/EXIT PROGRAMMING MODE NOTES 256 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Chapter 4 Wireless Features The features in this section are valid only for the GM4100 and GBT4100 models. This section provides options and programming related to the reader’s STAR and Bluetooth communication features. Reference Appendix B, Standard Defaults for a listing of standard factory settings. WIRELESS BEEPER FEATURES starting on page 259 • Good Transmission Beep • Disconnect Beep • Beep Frequency • Base Station Beep • Beep Duration • Leash Alarm • Beep Volume • CONFIGURATION UPDATES starting on page 264 • Automatic Configuration Update • Automatic Flash Update • Copy Configuration to Scanner • Request Flash Update • Copy Configuration to Base Station • POWERDOWN TIMEOUT starting on page 266 BATCH FEATURES starting on page 268 • Batch Mode • Erase Batch Memory • Send Batch • RF Batch Mode Transmit Delay DIRECT RADIO AUTOLINK starting on page 270 RF ADDRESS STAMPING starting on page 270 • Source Radio Address Transmission Product Reference Guide • Source Radio Address Delimiter Character 257 ENTER/EXIT PROGRAMMING MODE FEATURES FOR STAR MODELS ONLY starting on page 272 • STAR Radio Protocol Timeout • STAR Radio Transmit Mode DISPLAY FEATURES starting on page 274 • Contrast • Display Mode • Font Size • Display Timeout • Backlight • Keypad Select BLUETOOTH-ONLY FEATURES starting on page 279 BT SECURITY FEATURES • BT Security Mode • Select PIN Code Length • BT Pin Code • Set PIN Code BT HID Send Unkown ASCII Char BT HID FEATURES • BT HID Variable PIN Code • • BT HID ALT Mode • OTHER BT FEATURES • BT Poll Rate • 258 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Good Transmission Beep WIRELESS BEEPER FEATURES Several options are available to configure beeper behavior for RF operation. Good Transmission Beep Enables/disables the Good Transmission Beep indication. When enabled, a beep occurs when a Label is correctly transmitted to the base. Good Transmission Beep = Disable DEFAULT Good Transmission Beep = Enable Beep Frequency Adjusts radio-specific beep indications to sound at a low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.) DEFAULT Beep Frequency = Low Beep Frequency = Medium Beep Frequency = High Product Reference Guide 259 Wireless Beeper Features ENTER/EXIT PROGRAMMING MODE Beep Duration This feature controls the duration of radio-specific beep indications. Beep Duration = 60 msec Beep Duration = 80 msec DEFAULT Beep Duration = 100 msec Beep Duration = 120 msec Beep Duration = 140 msec Beep Duration = 160 msec Beep Duration = 180 msec Beep Duration = 200 msec 260 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Beep Volume Beep Volume Selects the beeper volume (loudness) of radio-specific beep indications. There are three selectable volume levels. Beep Volume = Low Beep Volume = Medium DEFAULT Beep Volume = High Disconnect Beep Enables/disables the beep indication that a handheld has become connected or disconnected from a Base Station. The defaults are different for the STAR and BT models. DEFAULT GM 4100 STAR default Disconnect Beep = Disable DEFAULT Disconnect Beep = Enable BT default Product Reference Guide 261 Wireless Beeper Features ENTER/EXIT PROGRAMMING MODE Base Station Beep Enables/disables a beep indication when the handheld is placed in the Base Station. BT Base Station Beep = Disable DEFAULT BT Base Station Beep = Enable Leash Alarm This setting specifies the number of seconds to sound the Leash Mode beeps (three per second) when the handheld goes out of range. This is especially useful in instances where the reader might inadvertently have been placed in a bag or cart. For this mode to be effective, reader must be linked to the Base Station and Sleep Mode Timeout on page 94 must be disabled. If the reader is asleep or disconnected from the Base Station, there is no way for it to know where it is relative to the Base Station because communication is not active between the devices. DEFAULT Leash Alarm = Disabled Leash Alarm = 1 Second Leash Alarm = 2 Seconds 262 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Leash Alarm Leash Alarm — cont. Leash Alarm = 3 Seconds Leash Alarm = 4 Seconds Leash Alarm = 5 Seconds Leash Alarm = 10 Seconds Leash Alarm = 25 Seconds Leash Alarm = 30 Seconds Product Reference Guide 263 Configuration Updates ENTER/EXIT PROGRAMMING MODE CONFIGURATION UPDATES See page 318 in “References” for detailed information and examples of these features. Automatic Configuration Update When this feature is enabled, a reader and its linked Base Station can automatically ensure they stay in sync with regard to application hardware and/or configuration. See page 318 for more information on this feature. Automatic Configuration Update = Disable DEFAULT Automatic Configuration Update = Enable Copy Configuration to Scanner Scan the following label to copy the current Base Station configuration to the scanner. Use this method when the Auto Configuration Update feature is disabled and you want a one-time configuration update to be performed on the scanner. Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with this barcode. Copy Configuration to Scanner 264 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Copy Configuration to Base Station Copy Configuration to Base Station Scan the following label to copy the current scanner configuration to the Base Station. Use this method when the Auto Configuration Update feature is disabled and you want a one-time configuration update to be performed on the Base Station. Copy Configuration to Base Station Do not scan an ENTER/EXIT PROGRAMMING MODE label with this barcode. Automatic Flash Update This feature enables/disables the automatic flash update of a reader. This item is valid only with POS version of Base Station (model 4010). DEFAULT Automatic Flash Update = Disable Automatic Flash Update = Enable Product Reference Guide 265 Configuration Updates ENTER/EXIT PROGRAMMING MODE Request Flash Update Scan this barcode to request a flash update from a Base Station Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with this barcode. NOTE Request Flash Update Powerdown Timeout The Powerdown Timeout feature sets the time for automatically switching the unit off when the imager has been idle. Powerdown Timeout = Disable Powerdown Timeout = 10 minutes Powerdown Timeout = 20 minutes DEFAULT Powerdown Timeout = 30 minutes 266 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Powerdown Timeout Powerdown Timeout — continued Powerdown Timeout = 60 Minutes (1 Hour) Powerdown Timeout = 120 Minutes (2 Hours) Powerdown Timeout = 4 Hours Powerdown Timeout = 6 Hours Powerdown Timeout = 8 Hours Powerdown Timeout = 16 Hours Powerdown Timeout = 24 Hours Product Reference Guide 267 Batch Features ENTER/EXIT PROGRAMMING MODE BATCH FEATURES Batch Mode This option specifies whether to store labels in the handheld while disconnected from the base. Options are as follows: • Disabled — The handheld will not store/batch labels. • • Automatic — The handheld will store labels to RAM when the handheld goes out of range and is disconnected from the remote device. Manual — The handheld will always store labels to Flash memory. The user must manually send the stored labels to the remote device using a special "batch send" label. DEFAULT Batch Mode = Disabled Batch Mode = Automatic Batch Mode = Manual Send Batch Use this barcode to initiate sending of labels stored in batch memory. Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with this barcode. Send Batch 268 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Erase Batch Memory Erase Batch Memory Use this barcode to erase any labels stored in batch memory. Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with this barcode. Erase Batch Memory RF Batch Mode Transmit Delay Specifies the delay in 10 msec increments between transmitting labels stored in batch memory . DEFAULT RF Batch Mode Transmit Delay = No Delay RF Batch Mode Transmit Delay = 50 mS RF Batch Mode Transmit Delay = 100 mS RF Batch Mode Transmit Delay = 0.5 seconds RF Batch Mode Transmit Delay = 1 second RF Batch Mode Transmit Delay = 2.5 seconds Product Reference Guide 269 Direct Radio AutoLink ENTER/EXIT PROGRAMMING MODE DIRECT RADIO AUTOLINK This feature enables/disables the ability to link a wireless handheld to a base station without scanning the Unlink label first. DEFAULT Direct Radio Link = Unlink Label Required Direct Radio Link = Automatic Unlinking RF ADDRESS STAMPING These features allow configuration of source radio data inclusion. Source Radio Address Transmission Enables/disables the ability of source radio address information to be transmitted to the host and, if so, at what position with respect to the label data. See page 318 in “References” for detailed information and examples for setting this feature. When included as a prefix, the source-radio ID is displayed after all label formatting has been applied. The 6 byte hex address is sent as 12 ascii characters, i.e., an address of 00 06 66 00 1A ED will be sent as (shown in hex): 30 30 30 36 36 36 30 30 31 41 45 44 DEFAULT Source Radio Address Transmission = Do Not Include Source Radio Address Transmission = Prefix 270 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Source Radio Address Delimiter Character Source Radio Address Delimiter Character This option specifies the delimiter character to be placed between the label data and radio address when address stamping is enabled. This feature only applies if "Source Radio Address Transmission" on page 270 is enabled. Set Source Radio Address Delimiter Character Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT Product Reference Guide 00 = No Delimiter Character 271 RF Address Stamping ENTER/EXIT PROGRAMMING MODE Features for Star Models Only The features in this section are valid only for the Gryphon I GM4100 Star model: • STAR Radio Protocol Timeout • STAR Radio Transmit Mode DISPLAY FEATURES starting on page 274 • • • • • • Contrast Font Size Backlight Display Mode Display Timeout Keypad Select STAR Radio Protocol Timeout This parameter sets the valid wait time before transmission between the handheld reader and Base Station is considered failed. When setting this parameter, take into consideration the radio traffic (number of readers in the same area). The selectable range for this feature is from 02 to 25 seconds. See page 320 in “References” for detailed information and examples for setting this feature. Set Radio Protocol Timeout Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 272 02 = 2 Seconds Radio Protocol Timeout Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE STAR Radio Transmit Mode STAR Radio Transmit Mode Specifies the transmission protocol for Star communications. Options are: • ACK from cradle to scanner — signals a good transmission as soon as the Base Station receives a label • ACK when sent to host — scanner signals a good transmission as soon as the Base Station has sent the label to the host • ACK from host — scanner signals a good transmission as soon as the Base Station has sent the label to the host and host has replied with an acknowledge message. DEFAULT $ from cradle ACK ACK when sent to host ACK from host ACK from host works only for RS232 or USB-COM interfaces with ACK/ NACK disabled. If ACK from host is configured with any other interface conditions, it works like ACK when sent to host. See "Message Formatting" on page 323 for details. Product Reference Guide 273 Display Features ENTER/EXIT PROGRAMMING MODE DISPLAY FEATURES Contrast Read the code until the desired contrast is reached. Lighter Darker Font Size DEFAULT Font size = Small Font$ size = Medium Font $ size = Large 274 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Backlight Backlight DEFAULT Display$backlight = off Display $ backlight = on Display Mode The user can control the reader display behavior according to various selections. See page 318 in “References” for detailed information about each feature. DEFAULT Local $ Echo mode Normal mode Clear display after decode Product Reference Guide 275 Display Features ENTER/EXIT PROGRAMMING MODE Display Timeout Specifies how long the display will remain on after a display write. Display is forced on after any display write or after any reading phase. Display and backlight are turned off after this timeout expires. Display $Timeout = Disable Display Timeout = 1 Second Display Timeout = 2 Seconds $ Display Timeout = 3 Seconds Display Timeout = 4 Seconds 276 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Display Timeout Display Timeout - cont. $ Display Timeout = 5 Seconds Display Timeout= 6 Seconds Display Timeout = 7 Seconds DEFAULT Display Timeout = 8 Seconds Display Timeout = 9 Seconds Display Timeout$= 9.9 Seconds (9,900ms max.) Product Reference Guide 277 Display Features ENTER/EXIT PROGRAMMING MODE Keypad Select This parameter specifies the character that has to be sent from the scanner when one of the three keys are pressed. For example, when key1 is pressed a 0x3C '<' character is sent. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: DISPLAY KEYPAD SELECT. 4. Then read 3 HEX characters in the range 01-FE from the keypad in Appendix D, Keypad, corresponding to the left, center and right keys respectively. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. Disable Keypad $ Enable Keypad Select Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 278 3C3D3E Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Keypad Select Bluetooth-Only Features The features in this section are valid only for Gryphon Bluetooth models. Also reference the Setup section for instructions on Linking a BT Reader to a PC, starting on page 26. Please update the list as below: BT SECURITY FEATURES • • BT Security Mode BT Pin Code •Select PIN Code Length •Set PIN Code BT HID FEATURES • • • BT HID Variable PIN Code BT HID ALT Mode BT HID Send Unkown ASCII Char OTHER BT FEATURES • BT Poll Rate Product Reference Guide 279 BT Security Features ENTER/EXIT PROGRAMMING MODE BT SECURITY FEATURES The BT system can be set up to require a configurable PIN code to authenticate/connect BT devices, and encrypt the data. This can be done in one of two ways: • The scanner can be programmed with a PIN code using the bar codes in this section. • The Host can be set up to specify a custom security PIN code when a scanner attempts to connect. For more information about this feature, contact Datalogic Technical Support. The Gryphon GBT4100 can be set up to require a PIN code when connecting to the host. If you are adding new equipment to a system that uses a custom security PIN, please read this section for information before proceeding. Follow these steps to set the PIN code for a scanner: 1. Enable BT Security Mode by scanning the "Enable” bar code below. 2. Select a PIN code length of either 4 or 16 characters by scanning the appropriate bar code in "Select PIN Code Length" on page 281. 3. Scan the relevant bar code from "Set PIN Code" on page 281, then scan the desired alphanumeric characters from the keypad in Appendix D, Keypad to set the PIN code. See "BT-Only Features" on page 321 in "References” for more detailed information and examples for this feature. BT Security Mode This feature enables/disables authentication and encryption of the BT link. Use the feature "BT Pin Code" on page 281 to specify the pin code used to authenticate the BT Link. NOTE Changing the security mode setting will unlink the devices. If the Automatic Configuration Update is set to the default enabled setting, the devices must only be relinked. If the Automatic Configuration Update is set to the disabled setting, the Security Mode setting must also be updated in the Base Station using Aladdin. After the Base Station has been updated the devices must be relinked. DEFAULT BT Security Mode = Disable BT Security Mode = Enable 280 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 BT Pin Code BT Pin Code After enabling Security Mode (see "BT Security Mode on page 280), specify whether you want to set a 4-digit or a 16-digit PIN Code. See page 321 for detailed information and examples for setting this feature. Select PIN Code Length DEFAULT Select 4-character BT PIN Code Select 16-character BT PIN Code Set PIN Code Determine the desired characters for the PIN code, then convert to hexadecimal using the ASCII Chart on the inside back cover of this manual. See page 321 for detailed information and examples for setting this feature. DEFAULT Set 4-character BT Pin Code To configure this feature, scan the ENTER/EXIT PROGRAMMING MODE bar code above, then the desired bar code , followed by the digits from the Alphanumeric characters in Appendix D. Keypad representing your desired character(s). End by scanning the ENTER/EXIT bar code again. Set 16-character BT PIN Code Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL Product Reference Guide 281 BT HID Features BT HID FEATURES BT HID Variable PIN Code This feature specifies the selection available for Static or Variable Pin Code, when BT HID profile is configured. DEFAULT Use Static PIN Code Use Variable PIN Code BT HID ALT Mode This feature Enables/Disables the ability to transmit correctly a label content to the host regardless of the BT HID Country Mode selected, when BT HID profile is configured. DEFAULT HID ALT Mode = Disable HID ALT Mode = Enable 282 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 BT HID Send Unkown BT HID Send Unkown ASCII Char This feature Enable/Disable the ability of a BT HH to transmit a label containing an unknown character to the host, when BT HID profile is configured. DEFAULT HID Send Unkown ASCII Char = Disable HID Send Unkown ASCII Char = Enable Product Reference Guide 283 Other BT Features OTHER BT FEATURES BT Poll Rate This feature specifies the time between BT polls. BT Poll Rate = Maximum BT Poll Rate BT Poll Rate = 10 ms DEFAULT BT Poll Rate = 20 ms BT Poll Rate = 30 ms BT Poll Rate = 50 ms BT Poll Rate = 100 ms 284 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 BT Poll Rate BT Poll Rate (continued) BT Poll Rate = 150 ms BT Poll Rate = 200 ms BT Poll Rate = 500 ms BT Poll Rate = 990 ms Product Reference Guide 285 Other BT Features NOTES 286 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Chapter 5 Laser Features The features in this section are valid for the Gryphon L GD4300 model only. LASER SCAN ANGLE on page 288 LASER IDLE MODE on page 288 BI-DIRECTIONAL READ DECODING on page 289 ALWAYS ON SCAN MODE TIMEOUT on page 290 This section provides options and programming related to the reader’s laser features. Reference Appendix B, Standard Defaults for a listing of standard factory settings. For hands-free or stand operations, it is recommended that Flashing scan mode be used. See "Scan Mode" on page 101 for programming labels for this feature. For more information, go to page 314 in “References”. Product Reference Guide 287 ENTER/EXIT PROGRAMMING MODE Laser Scan Angle This feature sets the scan angle for the laser. The Narrow scan angle is helpful for selecting and reading a specific barcode among a tight grouping of labels. DEFAULT Laser Scan Angle = Normal (47 degrees) Laser Scan Angle = Narrow (35 degrees) Laser Idle Mode Laser Idle Mode option is applicable for; trigger Single, Trigger Hold Multiple & Trigger Pulse Multiple only. This configuration provides control over the laser scanning motor when the laser is not actively scanning. The options are: Dither Disable . Shuts down the motor (laser mirror dithering) during laser engine idle time to reduce overall scanner power consumption. Dither Enable. Allows the laser engine motor to continue dithering when laser is not active; may provide an improved read response time. DEFAULT Dither Disable Dither Enable 288 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ENTER/EXIT PROGRAMMING MODE Bi-Directional Read Decoding Bi-Directional Read Decoding This configuration provides control over the good read and barcode label requirement. This programming option for Gyphon Laser affects all barcode symbologies. Bi-Directional Read Disable. When Bi-directional reading is disabled, the laser scan is only required to obtain a valid label read in one scanning direction. Bi-Directional Read Enable. When enabled, the reader is must obtain a valid good read in both scanning directions as part of the label read/decode process. Enabled will provides increased decode reliability. Bi-Directional Read Disable DEFAULT Bi-Directional Read Enable Product Reference Guide 289 ENTER/EXIT PROGRAMMING MODE Always On Scan Mode Timeout When the Gryphon Laser is in Always On scanning mode, timeout periods can be configured. If the programmed Always On Timeout elapses, the reader will shut down and a trigger pull is required to resume operation. Always On Timeout: 1 Hour Always On Timeout: 2 Hours Always On Timeout: 3 Hours Always On Timeout: 4 Hours DEFAULT Always On Timeout: 5 Hours 290 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Chapter 6 References This section contains explanations and examples of selected barcode features. See the Configuration section for the actual barcode labels used to configure the reader. RS-232 Parameters RS-232 Only Baud Rate Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly. Stop Bits The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements. Parity This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. • Select None when no parity bit is required. • Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character. • Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character. Handshaking Control The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking Control includes the following options: • RTS — RTS is asserted during transmissions. CTS is ignored. • RTS/CTS — RTS is asserted during transmissions. CTS gates transmissions. Product Reference Guide 291 References • • RTS/XON/XOFF — RTS is asserted during transmissions. CTS is ignored. XON and XOFF gate transmissions. RTS On/CTS — RTS is always asserted. CTS gates transmissions. RTS/CTS Scan Control — RTS is asserted during transmissions. CTS gates transmissions and controls enable and disable state of scanner. RS-232/USB COM Parameters Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. To set the delay: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Go to page 47 and scan the barcode: SELECT INTERCHARACTER DELAY SETTING. 5. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit. This completes the procedure. See Table 28 for some examples of how to set this feature. Table 28. Intercharacter Delay Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 50ms 150ms 600ms 850ms 2 Divide by 10 (pad with leading zeroes to yield two-digits) 05 15 60 85 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT INTERCHARACTER DELAY SETTING 5 6 292 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘5’ ‘5’ and ‘0’ ‘6’ and ‘0’ ‘8’ and ‘5’ Scan ENTER/EXIT PROGRAMMING MODE Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 RS-232 Parameters ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Options are: • Disable • Enable for label transmission — The reader expects an ACK/NAK response from the host when a label is sent. • Enable for host-command acknowledge — The reader will respond with ACK/NAK when the host sends a command. • Enable for label transmission and host-command acknowledge ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. 1. Determine the desired character or value. 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value. 3. Go to page 50 and scan ENTER/EXIT PROGRAMMING MODE to enter Programming Mode. 4. Scan the barcode: SELECT ACK CHARACTER SETTING. 5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix D, Keypad, that represent the desired character/value in step 1 above. The second character will cause a two-beep indication. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit. See Table 29 for some examples of how to set this feature. Table 29. ACK Character Setting Examples STEP ACTION EXAMPLES 1 Desired Character/Value ACK $ @ > 2 Hex equivalent from ASCII Chart 0x06 0x24 0x40 0x3E 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT ACK CHARACTER SETTING 5 Scan Two Characters from Appendix D, Keypad 6 Product Reference Guide ‘0’ and ‘6’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’ Scan ENTER/EXIT PROGRAMMING MODE 293 References NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set this feature: 1. Determine the desired character or value. 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value. 3. Go to page 50 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT NAK CHARACTER SETTING. 5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix D, Keypad, that represent the desired character/value in step 1 above. The second character will cause a two-beep indication. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 30 for some examples of how to set this feature. Table 30. NAK Character Setting Examples STEP ACTION EXAMPLES 1 Desired Character/Value NAK $ @ > 2 Hex equivalent from ASCII Chart 0x15 0x24 0x40 0x3E 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT ACK CHARACTER SETTING 5 6 294 Scan Two Characters From Appendix D, Keypad ‘1’ and ‘5’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’ Scan ENTER/EXIT PROGRAMMING MODE Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 RS-232 Parameters ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. To set this value: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Go to page 51 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT ACK NAK TIMEOUT VALUE SETTING. 5. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 31 for some examples of how to set this feature. Table 31. ACK NAK Timeout Value Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 200ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 15,000ms (15 sec.) 2 Divide by 200 01 05 26 75 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT ACK NAK TIMEOUT VALUE SETTING 5 Scan Two Characters From Appendix D, Keypad 6 Product Reference Guide ‘0’ and ‘1’ ‘0’ and ‘5’ ‘2’ and ‘6’ ‘7’ and ‘5’ Scan ENTER/EXIT PROGRAMMING MODE 295 References ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. To set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Go to page 51 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT ACK NAK RETRY COUNT SETTING. 5. Scan the appropriate three digits from the keypad in Appendix D, Keypad, that represent the number which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 32 for some examples of how to set this feature. Table 32. ACK NAK Retry Count Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Disable Retry Count 3 Retries 54 Retries Unlimited Retries 2 Pad with leading zero(es) 000 003 054 255 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT ACK NAK RETRY COUNT SETTING 5 6 296 Scan Three Characters From Appendix D, Keypad ‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘3’ ‘0’, ‘5’ and ‘4’ ‘2’, ‘5’ and ‘5’ Scan ENTER/EXIT PROGRAMMING MODE Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 RS-232 Parameters Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set the value: 1. Determine the desired character or value. A setting of 0xFF indicates the Disable Character is not used (not available). 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value. 3. Go to page 53 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT DISABLE CHARACTER SETTING. 5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix D, Keypad, that represent the desired character/value in step 1 above. The second character will cause a two-beep indication. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 33 for some examples of how to set this feature. Table 33. Disable Character Setting Examples STEP ACTION EXAMPLES 1 Desired character/value ‘d’ ‘}’ ‘D’ Disable Command Not Used 2 Hex equivalent from ASCII Chart 0x64 0x7D 0x44 0xFF 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT DISABLE CHARACTER VALUE SETTING 5 Scan Two Characters From Appendix D, Keypad 6 Product Reference Guide ‘6’ and ‘4’ ‘7’ and ‘D’ ‘4’ and ‘4’ ‘F’ AND ‘F’ Scan ENTER/EXIT PROGRAMMING MODE 297 References Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set this feature: Determine the desired character or value. A setting of 0xFF indicates the Enable Character is not used (not available). 1. Determine the desired character or value. 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value. 3. Go to page 53 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT ENABLE CHARACTER SETTING. 5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix D, Keypad, that represent the desired character/value in step 2 above. The second character will cause a two-beep indication. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 34 for some examples of how to set this feature. Table 34. Enable Character Setting Examples STEP ACTION EXAMPLES 1 Desired character/value ‘e’ ‘}’ ‘E’ Enable Command Not Used 2 Hex equivalent from ASCII Chart 0x65 0x7D 0x45 0xFF 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT DISABLE CHARACTER VALUE SETTING 5 6 298 Scan Two Characters From Appendix D, Keypad ‘6’ and ‘5’ ‘7’ and ‘D’ ‘4’ and ‘5’ ‘F’ AND ‘F’ Scan ENTER/EXIT PROGRAMMING MODE Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Keyboard Interface Keyboard Interface Wedge Quiet Interval Specifies the amount of time the reader looks for keyboard activity before it breaks the keyboard connection in order to transmit data to host. The range is from 0 to 990ms in 10ms increments. This feature applies ONLY to the Keyboard Wedge interface. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Go to page 62 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Prog. Mode. 4. Scan the barcode: SELECT WEDGE QUIET INTERVAL SETTING. 5. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit. This completes the procedure to set the Wedge Quiet Interval. See Table 35 for some examples of how to set this feature. Table 35. Wedge Quiet Interval Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 10ms 150ms 600ms 850ms 2 Divide by 10 (and pad with leading zeroes) 01 15 60 85 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT WEDGE QUIET INTERVAL SETTING 5 Scan Two Characters From Appendix D, Keypad 6 Product Reference Guide ‘0’ and ‘1’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’ Scan ENTER/EXIT PROGRAMMING MODE 299 References Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. This feature applies ONLY to the Keyboard Wedge interface. To set the delay: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Go to page 63 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT INTERCHARACTER DELAY SETTING. 5. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 36 for some examples of how to set this feature. Table 36. Intercharacter Delay Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 50ms 150ms 600ms 850ms 2 Divide by 10 (and pad with leading zeroes to yield twodigits) 05 15 60 85 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT INTERCHARACTER DELAY SETTING 5 6 300 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘5’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’ Scan ENTER/EXIT PROGRAMMING MODE Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Keyboard Interface Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc 3. Go to page 64 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT INTERCODE DELAY SETTING. 5. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 37 for some examples of how to set this feature. Table 37. Wedge Intercode Delay Examples STEP ACTION EXAMPLES 1 Desired Setting No Delay 5 Seconds 60 Seconds 99 Seconds 2 Pad with leading zero(es) 00 05 60 99 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT INTERCODE DELAY SETTING 5 Scan Two Characters From Appendix D, Keypad 6 Product Reference Guide ‘0’ and ‘0’ ‘0’ and ‘5’ ‘6’ and ‘0’ ‘9’ AND ‘9’ Scan ENTER/EXIT PROGRAMMING MODE 301 References Symbologies Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels. • Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors. • Level 3, which is the default setting, allows the majority of product labels to be decoded. There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level. Set Length Length Control allows you to select either variable length decoding or fixed length decoding for the specified symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set. Set Length 1 This feature specifies one of the barcode lengths for Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The number of characters that can be set varies, depending on the symbology. Reference the page for your selected symbology to see specific variables. 1. Determine the desired character length (varies depending on symbology). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Go to the Set Length page for your selected symbology and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode to SELECT LENGTH 1 SETTING for your selected symbology. 4. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Prog Mode. 302 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Symbologies Set Length 2 This feature allows you to set one of the barcode lengths for the specified symbology. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. See the page for the specific symbology for parameters. The length that can be set varies depending on the symbology. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1. Determine the desired character length (from 1 to 50 — or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Go to the Set Length page for your selected symbology and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode to SELECT LENGTH 2 SETTING for your selected symbology. 4. Scan the appropriate two digits from the keypad in Appendix D, Keypad that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake, before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. Product Reference Guide 303 References Data Editing It is not recommended to use these features with IBM interfaces. CAUTION When a barcode is scanned, additional information can be sent to the host computer along with the barcode data. This combination of barcode data and supplementary user-defined data is called a “message string.” The Data Editing features can be used to build specific user-defined data into a message string. There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. Figure 16 shows the available elements you can add to a message string: Figure 16. Breakdown of a Message String Label ID Transmission: Enable this option to transmit the Label ID you configure for the scanned symbology. Prefix Label ID AIM ID OR... Bar Code Data Label ID Suffix AIM ID: This function is used to identify and display the common label identifier for its symbology. When enabled, this ID code will be transmitted before the scanned bar code data. 00 - 20 Characters (ASCII) Additional advanced editing is available. See the Advanced formatting features in the Datalogic Aladdin configuration software, or contact Technical Support (described on page 10 for more information. Please Keep In Mind... • • • • 304 Modifying a message string is not a mandatory requirement. Data editing is a sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE. A prefix or suffix may be applied only to a specified symbology (reference Code Selection, starting on page 107) or across all symbologies (set via the Global features in this chapter). You can add any character from the ASCII Chart (from 00-FF) on the inside back cover of this manual as a prefix, suffix or Label ID. Enter prefixes and suffixes in the order in which you want them to appear on the output. Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Data Editing Global Prefix/Suffix Up to 20 ASCII characters may be added as a prefix (in a position before the barcode data) and/ or as a suffix (in a position following the barcode data) as indicated in Figure 17. Figure 17. Prefix and Suffix Positions OR... Prefix Label ID AIM ID Bar Code Data Label ID Suffix 00 - 20 Characters (ASCII) AND OR Example: Setting a Prefix In this example, we’ll set a prefix for all symbologies. 1. Determine which ASCII character(s) are to be added to scanned barcode data. In this example, we’ll add a dollar sign (‘$’) as a prefix. 2. Go to page 78 and scan the ENTER/EXIT PROGRAMMING MODE barcode. 3. Scan the SET GLOBAL PREFIX barcode. 4. Reference the ASCII Chart on the inside back cover of this manual to find the hex value assigned to the desired character. The corresponding hex number for the ‘$’ character is 24. To enter this selection code, scan the ‘2’ and ‘4’ barcodes from Appendix D, Keypad. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 5. If less than the expected string of 20 characters are selected, scan the ENTER/EXIT barcode to terminate the string. 6. Scan the ENTER/EXIT barcode once again to exit Programming Mode. 7. The resulting message string would appear as follows: Scanned barcode data:12345 Resulting message string output: $12345 Product Reference Guide 305 References Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by... • A code character (see the table below), followed by... • A modifier character (the modifier character is symbol dependent). SYMBOLOGY CHAR SYMBOLOGY CHAR UPC/EAN Ea Code 128/GS1-128 C Code 39 and Code 32 A DataBar Omnidirectional, DataBar Expanded e Codabar F Standard 2 of 5 S Interleaved 2 of 5 I ISBN Xb Code 93 G Code 11 H a. UPC-A and UPC-E labels are converted to EAN 13 when adding AIM IDs. b. ISBN (X with a 0 modifier character) Figure 18. AIM ID Prefix 306 Label ID AIM ID Bar Code Data Label ID Suffix Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Data Editing Label ID A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x010xFF), used to identify a barcode (symbology) type. It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs as a pre-loaded set (see "Label ID: Pre-loaded Sets" below) or individually per symbology (see "Label ID: Set Individually Per Symbology"on page 309). If you wish to program the reader to always include an industry standard label identifier for ALL symbology types, see "Global AIM ID"on page 79. Label ID: Pre-loaded Sets The reader supports two pre-loaded sets of Label IDs. Table 38 shows the USA and the EU sets. CAUTION When changing from one Label ID set to another, all other reader configuration settings, including the host interface type, will be erased and set to the standard factory defaults. Any custom configuration or custom defaults will be lost. Table 38. Label ID Pre-loaded Sets Symbology USA Label ID set EU Label ID set ASCII character Hexidecimal value ASCII character Hexidecimal value ABC Codabar S 530000 S 530000 Anker Plessey o 6F0000 o 6F0000 CODABAR % 250000 R 520000 Codablock F l 6C0000 m 6D0000 CODE11 CE 434500 b 620000 CODE128 # 230000 T 540000 CODE32 A 410000 X 580000 CODE39 * 2A0000 V 560000 CODE39 CIP Y 590000 Y 590000 CODE4 4 340000 4 340000 CODE5 j 6A0000 j 6A0000 CODE93 & 260000 U 550000 DATALOGIC 2OF5 s 730000 s 730000 EAN13 F 460000 B 420000 EAN13 P2 F 460000 L 4C0000 EAN13 P5 F 460000 M 4D0000 EAN13 P8 F 460000 # 230000 Product Reference Guide 307 References Label ID Pre-Loaded Sets (continued) Symbology USA Label ID set ASCII character Hexidecimal value ASCII character Hexidecimal value EAN8 FF 464600 A 410000 EAN8 P2 FF 464600 J 4A0000 EAN8 P5 FF 464600 K 4B0000 EAN8 P8 FF 464600 * 2A0000 FOLLETT 2OF5 O 4F0000 O 4F0000 GS1 DATABAR EXPANDED RX 525800 t 740000 GS1 DATABAR LIMITED RL 524C00 v 760000 GS1 DATABAR OMNIDIRECTIONAL R4 523400 u 750000 000000 k 6B0000 GS1-128 308 EU Label ID set GTIN G 470000 $A 244100 GTIN2 G2 473200 $B 244200 GTIN5 G5 473500 $C 244300 GTIN8 G8 473800 $D 244400 IATA IA 494100 & 260000 Industrial 2 of 5 W 570000 W 570000 Interleaved 2 of 5 i 690000 N 4E0000 Interleaved 2 of 5 CIP HR e 650000 e 650000 ISBN I 490000 @ 400000 ISBT128 f 660000 f 660000 ISSN n 6E0000 n 6E0000 MSI @ 400000 Z 5A0000 Plessey a 610000 a 610000 S25 s 730000 P 500000 UPCA A 410000 C 430000 UPCA P2 A 410000 F 460000 UPCA P5 A 410000 G 470000 UPCA P8 A 410000 Q 510000 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Data Editing Label ID: Set Individually Per Symbology To configure a Label ID individually for a single symbology: 1. Go to page 81 and scan the ENTER/EXIT barcode. 2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suffix) by scanning the appropriate barcode in the section "Label ID Control"on page 82. Reference Figure 19 for Label ID positioning options if multiple identification features are enabled. 3. Scan a barcode to select the symbology for which you wish to configure a custom Label ID from the section "Label ID Symbology Selection"on page 83. 4. Determine the desired character(s) (you may choose up to three) which will represent the Label ID for the selected symbology. 5. Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D. Turn to Keypad, starting on page 351 and scan the barcodes representing the hex characters determined. For the example given, the characters ‘3’ and ‘D’ would be scanned. More examples of Label ID settings are provided in Table 39. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT barcode to exit Label ID entry. 7. Scan the ENTER/EXIT barcode once again to exit Programming Mode. This completes the steps to configure a Label ID for a given symbology. Figure 19. Label ID Position Options Prefix Label ID Aim ID Bar Code Data Label ID Suffix OR Product Reference Guide 309 References Table 39. Label ID Examples STEP ACTION EXAMPLES 1. Scan the ENTER/EXIT barcode (Scanner enters Programming Mode) 2. Determine placement of the Label ID characters BEFORE or AFTER with regard to scanned Enable as Prefix data using Label ID Control, starting on page 82 Enable as Suffix Enable as Prefix Enable as Suffix 3. Scan the barcode selecting the symbology type you wish to DataBar designate label ID characters Omnidirectional for using Label ID Symbology Selection, starting on page 83. Code 39 Interleaved 2 of 5 Code 32 4. Custom Label ID example (desired characters): D B * =C3 + PH 5. Find hex equivalents from the ASCII Chart(inside back cover), then scan in these digits/characters using the barcodes in the section: Keypad, starting on page 351. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 44 42 2A 3D 43 33 2B 50 48 6. Scan the ENTER/EXIT barcode (Scanner exits Label ID entry) 7. Scan the ENTER/EXIT barcode once again (Scanner exits Programming Mode) Result: 310 DB*[barcode data] [barcode data]=C3 +[barcode data] [barcode data]PH Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Data Editing Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done. For example, if you have the character conversion configuration item set to the following: 41423132FFFFFFFF The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs are FFFF and FFFF. With the label, AB12BA21, it would look as follows after the character conversion: BB22BB22. The A characters were converted to B characters and the 1 characters were converted to 2 characters. Nothing is done with the last two character pairs, since they are all FF. To set Character Conversion: 1. Go to page 90 and scan the ENTER/EXIT barcode. 2. Scan the “Configure Character Conversion” barcode. 3. Determine the desired string. Sixteen positions must be determined as in the above example. Next, turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string. 4. Turn to Appendix D, Keypad and scan the barcodes representing the hex characters determined in the previous step. 5. Scan the ENTER/EXIT barcode to exit Programming Mode. If less than the expected string of 16 characters are selected, scan the ENTER/EXIT barcode twice to accept the selections and exit Programming Mode. Product Reference Guide 311 References Reading Parameters Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Go to page 93 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT LABEL GONE TIMEOUT SETTING. 5. Scan the appropriate three alpha-numeric characters from the keypad in Appendix D, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 40 for some examples of how to set this feature. Table 40. Timeout Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 50ms 150ms 1800ms (1.8 sec.) 2550ms (2.55 sec.) 2 Divide by 10 (and pad with leading zeroes) 005 015 180 255 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT LABEL GONE TIMEOUT SETTING 5 6 312 Scan Three Characters From Appendix D, Keypad ‘0’, ‘0’ and ‘5’ ‘0’, ‘1’ and ‘5’ ‘1’, ‘8’ and ‘0’ ‘‘2’, ‘5’ and ‘5’ Scan ENTER/EXIT PROGRAMMING MODE Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Reading Parameters Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 100ms increments. Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. A setting of 0 means that the good read LED stays on until the next time the trigger is pulled. 2. Divide the desired setting by 10 (setting is in 100ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc. 3. Go to page 100 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING. 5. Scan the appropriate three digits from the keypad in Appendix D, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 41 for some examples of how to set this feature. Table 41. Good Read LED Duration Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Good Read LED stays on until next trigger pull (00) 20ms 150ms 2550ms (2.55 sec.) 2 Divide by 10 (and pad with leading zeroes) 000 002 015 255 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT LABEL GONE TIMEOUT SETTING 5 Scan Three Characters From Appendix D, Keypad 6 Product Reference Guide ‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘2’ ‘0’, ‘1’ and ‘5’ ‘2’, ‘5’ and ‘5’ Scan ENTER/EXIT PROGRAMMING MODE 313 References Scanning Features Scan Mode This mode is associated with typical handheld reader operation. Selects the scan operating mode for the reader. The following selections are valid for all models: Trigger Single. When the trigger is pulled, scanning is activated until one of the following occurs: - Scanning Active Time has elapsed - a label has been read - the trigger is released Trigger Hold Multiple. When the trigger is pulled, scanning starts and the product scans until the trigger is released or Scanning Active Time has elapsed. Reading a label does not disable scanning. Double Read Timeout prevents undesired multiple reads of the same label while in this mode. Trigger Pulse Multiple. When the trigger is pulled, continuous scanning is activated until Scanning Active Time has elapsed or the trigger has been released and pulled again. Double Read Timeout prevents undesired multiple reads of the same label while in this mode. Flashing. The reader flashes1 on and off regardless of the trigger status. Flash rate is controlled by Flash On Time and Flash Off Time. When Flash is ON the imager reads continuously; when Flash is OFF scanning is deactivated. Flashing is the recommended scan mode for Gryphon L hands-free (stand mode) of operation Always On. No trigger pull is required to read a barcode. Scanning is continually on. If the trigger is pulled, the reader acts as if it is in Trigger Single Mode. Double Read Timeout prevents undesired multiple reads of the same label while in this mode. The following two features are valid only for the Gryphon I (desk and mobile), but not the Gryphon Laser model. See "Laser Features"on page 287 for specific parameters for the Laser model. Stand Mode. No trigger pull is required to read a barcode. Scanning is turned on automatically when an item is placed in the reader’s field of view. If the trigger is pulled, the reader acts as if it in single read mode. Double Read Timeout prevents undesired multiple reads while in this mode. Trigger Object Sense. This mode is similar to Stand Mode, except that a trigger pull is required to activate the decoder. 1. Controlled by Flash On Time. 314 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Scanning Features Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Go to page 104 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT SCANNING ACTIVE TIME SETTING. 5. Scan the appropriate three digits from the keypad in Appendix D, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 42 for some examples of how to set this feature. Table 42. Scanning Active Time Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 1 Second 90 Sec. (1.5 min.) 2 Pad leading zero(es) 001 090 180 Sec. (3 min.) 255 Seconds (4.25 min.) 180 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT SCANNING ACTIVE TIME SETTING 5 Scan Three Characters From Appendix D, Keypad 6 Product Reference Guide ‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ 255 ‘2’, ‘5’ and ‘5’ Scan ENTER/EXIT PROGRAMMING MODE 315 References Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Go to page 105 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT FLASH ON TIME SETTING. 5. Scan the appropriate two digits from the keypad in Appendix D, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 43 for some examples of how to set this feature. Table 43. Flash On Time Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 500ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 9,900ms (9.9 sec.) 2 Divide by 100 (and pad with leading zeroes to yield two digits) 05 10 52 99 ‘5’ and ‘2’ ‘9’ and ‘9’ 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT FLASH OFF TIME SETTING 5 6 316 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘5’ ‘1’ and ‘0’ Scan ENTER/EXIT PROGRAMMING MODE Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Scanning Features Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Go to page 105 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT FLASH OFF TIME SETTING. 5. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 44 for some examples of how to set this feature. Table 44. Flash Off Time Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 500ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 9,900ms (9.9 sec.) 2 Divide by 100 (and pad with leading zeroes to yield two digits) 05 10 52 99 ‘5’ and ‘2’ ‘9’ and ‘9’ 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT FLASH OFF TIME SETTING 5 Scan Two Characters From Appendix D, Keypad 6 Product Reference Guide ‘0’ and ‘5’ ‘1’ and ‘0’ Scan ENTER/EXIT PROGRAMMING MODE 317 References Display Settings Display Mode The user can control the reader display behavior according to the following selections: Local Echo mode: When a barcode is read with the reader: • The code is sent to the Host. • The reader display is cleared. • The code is also sent to the reader display (Local Echo). • The cursor is positioned after the last printed character on the reader display. Normal mode: When a barcode is read with the reader: • The code is sent to the Host. • The reader display is not cleared. Therefore if any previous data was displayed on the reader screen it remains. • There is no Local Echo to the reader display. Clear Display After Decode mode: When a barcode is read with the reader: • The code is sent to the Host. • The reader display is cleared. Therefore if any previous data was displayed on the reader screen it is cancelled and the screen remains blank. • There is no Local Echo of the code to the reader display. Host messages sent to the reader are always written to the reader display. RF Features Configuration Update Automatic Configuration Update When this feature is enabled, the base station and reader will keep their configurations synchronized. If a reader's configuration is altered by reading programming labels, this change is automatically transferred and updated in a linked base station. Likewise, if the base station's configuration is changed using Aladdin or by host commands, then the reader's configuration will automatically be updated if this feature is enabled. RF Address Stamping Source Radio Address Delimiter Character This option specifies the delimiter character to be placed between the label data and radio address when address stamping is enabled. This feature only applies if "Source Radio Address Transmission"on page 270 is enabled. 318 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 RF Features Follow these instructions to select the delimiter character: 1. Determine the desired character, then find its hexadecimal equivalent on the ASCII Chart on the inside back cover. A setting of 00 specifies no delimiter character. 2. Go to page 271 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SET SOURCE RADIO ADDRESS DELIMITER CHARACTER. 4. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the hexidecimal characters which were determined in the steps above. You will hear a twobeep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 45 for some examples of how to set this feature. Table 45. Source Radio Address Delimiter Character Setting Examples STEP ACTION EXAMPLES 1 Desired Setting No delimiter character , (comma) - (dash) 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SET SOURCE RADIO ADDRESS DELIMiTER CHARACTER 4 Scan Two Characters From Appendix D, Keypad 5 Product Reference Guide ‘0’ and ‘0’ ‘2’ and ‘C’ ‘2’ and ‘D’ / (slash) ‘2’ AND ‘F’ Scan ENTER/EXIT PROGRAMMING MODE 319 References STAR Radio Protocol Timeout This parameter sets the valid wait time before transmission between the handheld reader and Base Station is considered failed. When setting this parameter, take into consideration the radio traffic (number of readers in the same area). The selectable range for this feature is from 02 to 25 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 25 = 25, etc 3. Go to page 272 and scanScan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT. 5. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 46 for some examples of how to set this feature. Table 46. STAR Radio Protocol Timeout Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Seconds 5 Seconds 10 Seconds 25 Seconds 2 Pad with leading zero(es) 02 05 10 25 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT INTERCODE DELAY SETTING 5 6 320 Scan Two Characters From Appendix D, Keypad ‘0’ and ‘2’ ‘0’ and ‘5’ ‘1’ and ‘0’ ‘2’ AND ‘5’ Scan ENTER/EXIT PROGRAMMING MODE Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 RF Features BT-Only Features BT Pin Code This option specifies the pin code (either 4- or 16-characters) to be used for authentication of the BT link. To set the pin code: 1. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode, then enable "BT Security Mode" on page 280. 2. Specify the desired pin code length (4 or 16) by scanning the appropriate bar code in "Select PIN Code Length" on page 281. 3. Determine the desired characters. For example, D254 or TOR12345678135M 4. Convert the characters to hexadecimal using the ASCII Chart on the inside back cover of this manual. 5. Go to page 281 and Scan the bar code: SET 4 CHAR PIN CODE or SET 16-CHAR PIN CODE. 6. Scan the appropriate alphanumeric characters from the keypad in Appendix D, Keypad, representing the hexadecimal entries determined in the steps above. You will hear a twobeep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 7. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode. Changing the pin code setting will unlink the devices. If the Automatic Configuration Update is set to the default enabled setting, the devices must only be relinked. If the Automatic Configuration Update is set to the disabled setting, the Pin Code setting must also be updated in the Base Station using Aladdin. After the Base Station has been updated, the devices must be relinked. Table 47. BT Pin Code Setting Examples STEP ACTION EXAMPLES 1 Desired Setting D254 STOR12345678135M 2 Convert the characters to hexadecimal 44 32 35 34 53 54 4F 52 31 32 33 34 35 36 37 38 31 33 35 4D 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SET BT PIN CODE 5 Scan 8 or 32 Alphanumeric Characters From Appendix 44323534 53544F5231323334353637383133354D D, Keypad 6 Product Reference Guide Scan ENTER/EXIT PROGRAMMING MODE 321 References NOTES 322 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Chapter 7 Message Formatting Message Formatting Message Formatting is only available for the Gryphon™ Mobile model. A message from the Host to the base must follow these rules: • If Address stamping options or address delimiter are enabled on the base, the Host replay must have address field and delimiter too. Otherwise the message will be ignored. Address delimiter is present only when address stamping is enabled. • Address stamping is necessary to correctly route the message to the Gryphon I, especially when more than one handheld is linked to the same base. Address stamping could be disabled if the system is in point to point configuration. If address stamping is not enabled, the messages are addressed to the first handheld linked to the base. • Messages end with “CR” 0x0D ASCII character. The CR character cannot be contained in the middle. • Messages cannot start with '$' or # because these are reserved for Service mode command • Base station can receive host message only if Host Commands Obey/Ignore is set to Ignore. • Message could be sent to the HH in response to a Label when “Transmit mode” require Ack from Host (see transmit mode parameter) or at any time. When messages are sent not in response to a label must start with DC2 0x12 ASCII character and could be sent in any transmit mode setting. • Message could be sent to all HH linked to base by using a Multicast message: “00 00 00 00 2A AA” • In order to receive a message, handhelds must not be in sleep state. The format of the ACK from Host message (used for transmission mode 02) is: [Scanner_Addr] [Scanner_Addr_delimiter] MESSAGE <CR> The format of a generic message From Host to HH is: [Scanner_Addr] [Scanner_Addr_delimiter] DC2 MESSAGE <CR> where DC2 is ASCII 0x12 (^R) character. [Items in square brackets are optional.] Product Reference Guide 323 Message Formatting • If you want to control the Scanner's beeper from the host, you will also probably want to disable the good transmission beep that is emitted when the code is received from the cradle. (See Wireless Beeper Features on page 259). The message field can store plain text and escape sequences. • Escape sequences are interpreted as commands. • Plain text is directly printed on the display. If writing beyond the end of line, the display does not wrap automatically. Extra characters are ignored. Control characters are not interpreted (i.e. LF, FF, etc.). Cursor Control ESC [ n A Up n rows, no scroll ESC [ n B Down n rows, no scroll ESC [ n C Right n columns ESC [ n D Left n columns ESC [ G CR ESC [ r ; c H Move to row r , column c (ESC[1;1H is the upper left character position of the display) ESC D Down 1 row, with scroll CR and cursor down 1 row with scroll Up 1 row and scroll ESC E ESC M NOTES: • • • Since CR is used as the message terminator, you must use ESC [ G or ESC E to print a CR. The cursor row position is not affected by the currently selected font. The display always has 4 rows, so when writing with the large font, actually two rows are written to: the current one and the one below it. You will need two ESC E commands to step from one row to the next when using the large font. The cursor column position is affected by the currently selected font. Therefore, column 6 is 36 pixels from the left border only if you last selected the 6x8 font; otherwise it could be 48 or 72 pixels from the left border. Font Selection ESC [ 0 m ESC [ 7 m ESC # 4 ESC # 5 ESC # 7 324 Normal mode Reverse mode Large font: subsequent characters are written on the current row and the row below it using the 12x16 font which allows for two rows of eight characters on the display. Normal font: subsequent characters are written using the 6x8 font, which allows for four rows of sixteen characters on the display. Medium font: subsequent characters are written using the 8x8 font, which allows for 4 rows of 12 characters on the display. Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Message Formatting Clearing Display ESC [ 0 K ESC [ 1 K ESC [ 2 K ESC [ 0 J ESC [ 1 J ESC [ 2 J From cursor position to end of line inclusive From beginning of line to cursor position (not inclusive) Entire line From cursor position to end of display inclusive From beginning of display to cursor position (not inclusive) Entire display; moves cursor to upper left corner on display LED and Beeper Control ESC [ 0 q ESC [ 1 q ESC [ 2 q ESC [ 3 q ESC [ 4 q ESC [ 5 q ESC [ 6 q ESC [ 7 q ESC [ 8 q ESC [ 9 q ESC [ 0 r ESC [ 1 r Emit short High tone + short delay Emit short Low tone + short delay Emit long Low tone + short delay Emit good read tone Emit bad tx tone Wait 100 ms Turn on the green LED Turn off the green LED Turn on the green spot Turn off the green spot Beep for Find me function (new) Power-off (new) The LED control escape sequences are intended to activate the LEDs for short periods of time and can be used in combination with the Beeper. The LED and Beeper will be controlled by the system after the entire command sequence is interpreted. Example: Turns on the green LED, emits a good read tone, and turns off the green LED. ESC [ 6 q ESC [ 5 q ESC [ 7 q Turns on the green LED for 100 ms and then turns off the green LED. ESC [ 6 q ESC [ 3 q ESC [ 7 q Product Reference Guide 325 Message Formatting Messages from Scanner Command Keys The Gryphon™ I series scanners with display have 3 command keys that can each be associated with a character to send to the host. By pressing the keys on the scanner, the associated character with its relative message formatting is sent to the Host. For example, keys can be used to select items from a menu sent to the scanner display by the application program. The messages are handled by the system as if they were barcodes, that's why KeyID can have so many fields appended to it. If in your application there is some chance of reading a 1-char barcode identical to KeyID, the way you can distinguish between the two is to enable the Code ID: The KeyID is the only 1-character long EAN 8 code. The default characters associated with each key (KeyID) are shown in the following table: 326 (left) Key '<' (center) Key '=' (right) Key '>' Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Appendix A Technical Specifications Table 48 contains Physical and Performance Characteristics, User Environment and Regulatory information. Table 49 provides Standard Cable Pinouts. Table 48. Technical Specifications Item Description Physical Characteristics Color Dimensions Weight (without cable) White/Gray Gray/Gray Height 7.1”/181 mm Length 3.9”/100 mm Width 2.8”/71 mm GD 41x0/GD4300 : Approximately 6.0 ounces/169 g GM4100/GBT4100: Approximately 8.7 ounces/246 g BC40x0: Approximately 8.7 ounces/246 g BC40x0-CF: Approximately 10.1 ounces/290 g Electrical Characteristics Voltage & Current GD4130 model: 5V±5% Input range. 1.9W max. 360 mA (max) at 5V 2.5 mA RS-232 sleep mode/ USB suspend GD4330 model: Input current at 5V±5% = 260 mA (max) 2.5 mA (USB suspend) Standby (typical) <= 30mA GD4110 model: 4.5÷14V Input range. Power 1.8W max. 340 mA (max) at 5V. 2.5 mA (RS-232 sleep mode / USB suspend) GD4310 model: Input Power = 1.2W max in the 4.5÷14V range 2.5 mA (USB suspend) Standby (typical): 30mA @5V (90mA @5V for IBM46xx) BC40x0 base: 4.75-14V; Input range. Power 8W max a; Imax 500mA when in host/bus powered modea. Battery Type Charge time for full charge from full discharge Product Reference Guide BC40x0-CF base: 10-14V; Input range. Power 8W maxa ; Imax 800mA . Li-Ion battery pack 4 hours with 12v external power supply adapterb Max 22h hours with Host power (In this case no supply adapter is needed)b 327 Technical Specifications Item Description Operating autonomy (continuous reading) Performance Characteristics Light Source GM4100: 50,000 reads (typical) GBT4100: 30,000 reads (typical) GD41x0 model: GD43x0 model: Dual LEDs 650nm Class 2 Laser Roll (Tilt) Tolerance ± 35° from normal Pitch Tolerance GD 41x0/GM4100/GBT4100: ± 65° GD4300: ± 50° Skew (Yaw) Tolerance Field of View Depth of Field (Typical) c ( Minimum Element Width Print Contrast Minimum ± 65° 10” (25.4cm) wide at 12.5” (31.8cm) from the reader 3 mil – 2.9” to 4.7” (7.5cm to 12cm) 13 mil c – 1.2” to 23.6” (3cm to 60cm) 20 mil – 1.2” to 31.5” (3cm to 80cm) Scan Angle: 47° (normal) or 35° (narrow) 5 mil - 1.4" to 6.22" (3,6cm to 15,8cm) 13 milc – 0.87" to 18.7" (2,2cm to 47,5cm) 20 mil – up to 27.1" (to 69cm) 3 mil 4 mil 15% minimum reflectance Decode Capability UPC/EAN/JAN, P2 /P5, ISBN/ISSN; Code 39, Code39 FullASCII; Italian Pharmacode 39, Code39 CIP; Code 128, GS1-128; C128 ISBT; Code 128 addons;I 2 of 5; Standard 2 of 5; I 2 of 5 CIP HR; Industrial 2 of 5; IATA; Datalogic 2 of 5; Follet 2 of 5; Code 11; Plessey, Anker Plessey; Codabar, ABC Codabar ; Code 93; MSI; GS1 DataBar™ Omnidirectional, GS1 DataBar™ Limited, GS1 DataBar™ Expanded; Code 4, Code 5; Codablock F, Codablock F EAN; Interfaces Supportedd RS-232 Std, RS-232 Wincor-Nixdorf, RS-232 OPOS, IBM 46xx (ports 5B and 9B), USB Com Std., USB Keyboard, USB Alternate Keyboard,USB OEM, Keyboard Wedge (AT with or w/o Alternate Key, IBM AT PS2 with or w/o Alternate Key, PC-XT, IBM 3153, IBM Terminals 31xx, 32xx,34xx, 37xx make only and make break keyboard, Digital Terminals VT2x, VT3xx, VT4xx, and Apple) and Wand Emulation. User Environment Operating Temperature GD 41x0: 32° to 131° F (0° to 55° C) GM4100/GBT4100/GD4300: 32° to 122° F (0° to 50° C) Charging Temperature 32° to 104° F (0° to 40° C) Storage Temperature -4° to 158° F (-20° to 70° C) Humidity Drop Specifications Operating: 5% to 90% relative humidity, non-condensing 18 drops from 1.8 meters (5.9 feet) to concrete Ambient Light Immunity Up to 100,000 Lux Contaminants Spray/Rain/ Dust/Particulates IP52 ESD Level 328 16 KV Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Technical Specifications Item Description Regulatory Electrical Safety EMI/RFI See the Quick Reference Guide for each specific product for details. Laser Safety LED class safety a. b. c. d. Typical input current measured under factory default configuration. Charge Times are much lower when battery is within daily typical operating condition. 13 mils DOF based on EAN. All others are Code 39. All labels grade A, typical environmental light, 20°C, label inclination 10° See "Interface Selection"on page 29 for a listing of available interface sets by model type. Model Radio Features Working Center Frequency Range (in open air) Max. number of devices per base station Product Reference Guide 433MHz model 910 Mhz BT 433.920 MHz 910.000 MHz 2400 to 2483.5 MHz 30 m 15 m 30 m 16 16 1 329 Technical Specifications Standard Cable Pinouts Figure 20 and Table 49 provide standard pinout information for the Base Station’s interface cable. Figure 20. Standard Cable Pinouts Bottom of Scanner Cable Strain Relief Pin 10 To Host Pin 1 Cable Clip (Latch) Cable Interface Cable Port The signal descriptions in Table 49 apply to the connector on the reader and are for reference only. Table 49. Standard Cable Pinouts — Reader Side Pin RS-232 1 RTS (out) USB Keyboard Wedge 2 D+ CLKIN (KBD side) 3 D- DATAIN (KBD side) GND GND GND VCC VCC VCC 4 GND 5 RX 6 TX 7 VCC 8 IBM_B CLKOUT (PC side) 9 IBM_A DATAOUT (PC side) 10 330 OEM CTS (in) Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Technical Specifications LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The tables below list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on. For example, certain indications such as the power-up beep can be disabled using programming barcode labels. Table 50. LED and Beeper Indications INDICATION DESCRIPTION Power-up Beep The reader is in the process of powering-up. Good Read Beep A label has been successfully scanned by the reader. ROM Failure There is an error in the reader's software/programming Limited Scanning Label Read Indicates that a host connection is not established when the IBM or USB interface is enabled. Reader Active Mode LED BEEPER Reader beeps four times at highest frequency and volume upon power-up. LED behavior for this indication is configurable via the feature “Good Read: When to Indicate” The reader will beep once at current frequency, volume, mono/bitonal setting and duration upon a successful label scan. Flashes Reader sounds one error beep at highest volume. N/A Reader 'chirps' six times at the highest frequency and current volume. The reader is active and ready to scan. The LED is lit steadilya N/A Reader Disabled The reader has been disabled by the host. The LED blinks continuously Green Spot is on continuously While in Stand Mode or Trigger Stand Mode the green spot shall be on while in stand watch state. N/A N/A Green Spota flashes momentarily Upon successful read of a label, the software shall turn the green spot on for the time specified by the configured value. N/A N/A N/A a. Except when in sleep mode or when a Good Read LED Duration other than 00 is selected Product Reference Guide 331 Technical Specifications Table 51. Programming Mode Indications Programming Mode - The following indications ONLY occur when the reader is in Programming Mode. Label Programming Mode Entry A valid programming label has been scanned. Label Programming Mode Rejection of Label A label has been rejected. Label Programming Mode Acceptance of Partial Label In cases where multiple labels must be scanned to program one feature, this indication acknowledges each portion as it is successfully scanned. Label Programming Mode Acceptance of Programming Configuration option(s) have been successfully programmed via labels and the reader has exited Programming Mode. Label Programming Mode Cancel Item Entry Cancel label has been scanned. LED blinks continuously N/A N/A N/A N/A Reader sounds four low frequency beeps. Reader sounds three times at lowest frequency & current volume. Reader sounds one short beep at highest frequency & current volume. Reader sounds one high frequency beep and 4 low frequency beeps followed by reset beeps. Reader sounds two times at low frequency and current volume. Error Codes Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is reset, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found. NUMBER OF LED FLASHES/BEEPS ERROR 1 Configuration 2 Interface PCB 4 Reader Module 5 Laser Pointer (if so equipped) 6 Digital PCB 14 CPLD/Code Mismatch CORRECTIVE ACTION Contact Helpdesk for assistance 332 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Technical Specifications Base Station Indications (Cordless Models ONLY) INDICATION LEDS Power-up Complete Yellow LED on Reader Disabled by the HOST or the communication with HOST is not established Yellow LED blinking ~1Hz Data/labels are transmitted to the HOST Yellow LEDs turned off for 100mSec Programming Mode Yellow LED blinks quickly Base and handheld are exchanging data Red LED blinks quickly Battery charging in progress Red LED on Battery charging complete Green LED on Battery charger error Green LED and Red LEDs blink alternatively ~1Hz No handheld is placed on the cradle Red and Green LEDs off Base Station Button Indicators BUTTON PUSH EVENT CORDLESS YELLOW INDICATOR RED INDICATOR GREEN INDICATOR Push at power-up Force device connection (Aladdin) Off Off Slow blink Fast blink < 1 sec (*) UV LED On/Off Off Off Off 1 to 5 sec Paging Off Off Fast blink 5 to 10 sec Unlink (Only BT) Off Off Slow blink 10 to 20 sec Reset Off Fast blink Off > 20 sec Restore factory defaults Off Slow blink Off (*) Only for models with UV Counterfeit Money Detector. See page 12 for more details Product Reference Guide 333 Technical Specifications NOTES 334 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Appendix B Standard Defaults The most common configuration settings are listed in the “Default” column of the table below. Page references are also provided for feature descriptions and programming barcodes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features. Table 52. Standard Defaults Parameter Default Your Setting Page Number GLOBAL INTERFACE FEATURES Host Commands — Obey/Ignore Obey 39 Disable 39 Baud Rate 9600 42 Data Bits 8 Data Bits 43 Stop Bits 1 Stop Bit 43 None 44 RTS 45 No Delay 47 Beep On ASCII BEL Disable 47 Beep On Not on File Enable 48 ACK Character ‘ACK’ 50 NAK Character ‘NAK’ 50 ACK NAK Timeout Value 200 ms 51 ACK NAK Retry Count 3 Retries 51 Ignore Errors Detected 52 USB Suspend Mode RS-232 ONLY Parity Handshaking Control RS-232/USB-Com Intercharacter Delay ACK NAK Error Handling Product Reference Guide 335 Standard Defaults Parameter Indicate Transmission Failure Default Your Setting Page Number Enable 52 Disable Character ‘D’ 53 Enable Character ‘E’ 53 Country Mode U.S. Keyboard 56 Caps Lock State Caps Lock OFF 59 Numlock Key Unchanged 60 Control Character 00 61 Wedge Quiet Interval 100 ms 62 Intercharacter Delay No Delay 63 100 ms 64 1 ms 65 Standard Keys 66 Handheld Scanner 68 Ignore Host Configuration Commands 68 6 70 IBM Standard Format 72 Ignore Scanner Configuration Host Commands 72 660 ms 74 Quiet Zones & Spaces High, Bars Low 74 Wand Idle State High 75 Transmit Noise Disable 75 No conversion 76 No Global Prefix Global Suffix = 0x0D (CR) 78 Disable 79 KEYBOARD WEDGE Numlock Send Control Characters Intercode Delay USB Keyboard Speed USB Keyboard Numeric Keypad USB-OEM USB-OEM Device Usage Interface Options IBM 46xx 46xx Number of Host Resets Transmit Labels in Code 39 Format Interface Options Wand Emulation Wand Signal Speed Wand Polarity Label Symbology Conversion Data Format Global Prefix/Suffix Global AIM ID 336 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Standard Defaults Parameter Default Your Setting Page Number GS1-128 AIM ID Enable 80 Label ID: Pre-loaded Sets USA Set 81 Label ID Control Disable 82 No Mid Label ID Character 89 Disable 90 No Char Conversion 90 0.6 Second 91 Label Gone Timeout 160 ms 93 Sleep Mode Timeout Disable 94 Power On Alert 4 Beeps 96 After Decode 96 Mono 97 Medium 97 Good Read Beep Length 80 ms 98 Good Read Beep Volume High 99 Good Read LED Duration 300 ms 100 Trigger Single 101 0.5 second 102 Switch to Stand mode 103 Medium 104 Scanning Active Time 5 Seconds 104 Flash On Time 1 Second 105 Flash Off Time 600 ms 105 Green Spot Duration 300 ms 106 Enable UPCA coupon decoding 109 UPC-A Enable/Disable Enable 110 UPC-A Check Character Transmission Enable 110 Don’t Expand 111 Set Global Mid Label ID Characters Case Conversion Character Conversion READING PARAMETERS Double Read Timeout Good Read: When to Indicate Good Read Beep Type Good Read Beep Frequency Scan Mode Stand Mode Triggered Timeout Stand Detection Stand Mode Sensitivity Code Selection Coupon Control UPC-A Expand UPC-A to EAN-13 Product Reference Guide 337 Standard Defaults Parameter UPC-A Number System Character Transmission Default Your Setting Page Number Transmit 111 1 112 Enable 113 Send 113 Expand UPC-E to EAN-13 Don’t Expand 114 Expand UPC-E to UPC-A Don’t Expand 114 Transmit 115 2 115 Disable 116 Enable 117 Send 117 EAN-13 Flag 1 Character Transmit 118 EAN-13 ISBN Conversion Disable 118 EAN 13 Minimum Reads 1 119 Disable 120 Enable 121 Send 121 Expand EAN 8 to EAN 13 Disable 122 EAN 8 Minimum Reads 1 122 2 123 UPC/EAN Correlation Disable 124 UPC/EAN Price Weight Check Disable 124 2 125 Disable P2, P5 and GS1-128 126 70 ms 127 UPC-A Minimum Reads UPC-E UPC-E Enable/Disable UPC-E Check Character Transmission UPC-E Number System Character Transmission UPC-E Minimum Reads GTIN GTIN Formatting EAN 13 (Jan 13) EAN 13 Enable/Disable EAN 13 Check Character Transmission ISSN ISSN Enable/Disable EAN 8 EAN 8 Enable/Disable EAN 8 Check Character Transmission UPC/EAN Global Settings UPC/EAN Decoding Level In-Store Minimum Reads Add-Ons Optional Add-ons Optional Add-On Timer 338 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Standard Defaults Parameter Optional GS1-128 Add-On Timer Default Your Setting Page Number Disable 130 P2 Add-Ons Minimum Reads 2 133 P5 Add-Ons Minimum Reads 1 134 GS1-128 Add-Ons Minimum Reads 1 135 Enable 136 Don’t Calculate 136 Don’t Send 137 Don’t Transmit 138 Disable 138 Auto 139 Code 39 Minimum Reads 2 140 Code 39 Decoding Level 3 141 Code 39 Length Control Variable 142 Code 39 Set Length 1 2 143 Code 39 Set Length 2 50 144 Code 39 Interdigit Ratio 4 145 Code 39 Character Correlation Disable 147 Code 39 Stitching Enable 147 Disable 148 N/A 148 Don’t Send 149 Don’t Transmit 149 Disable 148 Enable 151 Don’t Expand 151 Send 152 Code 128 Function Character Transmission Don’t Send 152 Code 128 Sub-Code Change Transmission Disable 153 Code 39 Code 39 Enable/Disable Code 39 Check Character Calculation Code 39 Check Character Transmission Code 39 Start/Stop Character Transmission Code 39 Full ASCII Code 39 Quiet Zones Code 32 (Italian Pharmaceutical Code) Code 32 Enable/Disable Code 32 Feature Setting Exceptions Code 32 Check Char Transmission Code 32 Start/Stop Character Transmission Code 39 CIP (French Pharmaceutical Code) Code 39 CIP Enable/Disable Code 128 Code 128 Enable/Disable Expand Code 128 to Code 39 Code 128 Check Character Transmission Product Reference Guide 339 Standard Defaults Parameter Code 128 Quiet Zones Default Your Setting Page Number Auto 154 Code 128 Minimum Reads 1 155 Code 128 Decoding Level 3 156 Code 128 Length Control Variable 157 Code 128 Set Length 1 1 158 Code 128 Set Length 2 80 159 Code 128 Character Correlation Disable 160 Code 128 Stitching Enable 160 Transmit in GS1-128 data format 161 ISBT 128 Concatenation Disable 162 ISBT 128 Force Concatenation Disable 162 ISBT 128 Concatenation Mode Static 163 ISBT 128 Dynamic Concatenation Timeout 200 msec 164 ISBT 128 Advanced Concatenation Options Disable 164 Codablock F Enable/Disable Disable 165 Codablock F EAN Enable/Disable Disable 165 Enable check C 166 Variable 166 Codablock F Set Length 1 3 characters 167 Codablock F Set Length 2 100 characters 168 I 2 of 5 Enable/Disable Disable 169 I 2 of 5 Check Character Calculation Disable 169 Send 170 I 2 of 5 Minimum Reads 2 192 2 of 5 Decoding Level 3 192 I 2 of 5 Length Control Variable 173 6 174 GS1-128 GS1-128 Enable ISBT 128 Codablock F Codablock F AIM Check Codablock F Length Control Interleaved 2 of 5 I 2 of 5 Check Character Transmission I 2 of 5 Set Length 1 340 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Standard Defaults Parameter I 2 of 5 Set Length 2 Default Your Setting Page Number 50 175 I 2 of 5 Character Correlation Disable 176 I 2 of 5 Stitching Disable 176 Disable 177 Disable 177 Standard 2 of 5 Enable/Disable Disable 178 Standard 2 of 5 Check Character Calculation Disable 178 Send 179 Standard 2 of 5 Minimum Reads 2 179 Standard 2 of 5 Decoding Level 3 180 Standard 2 of 5 Length Control Variable 180 Standard 2 of 5 Set Length 1 8 181 Standard 2 of 5 Set Length 2 50 182 Standard 2 of 5 Character Correlation Disable 183 Standard 2 of 5 Stitching Disable 183 Industrial 2 of 5 Enable/Disable Disable 184 Industrial 2 of 5 Check Character Calculation Disable 184 Industrial 2 of 5 Check Character Transmission Enable 185 Industrial 2 of 5 Length Control Variable 185 Industrial 2 of 5 Set Length 1 1 186 Industrial 2 of 5 Set Length 2 50 187 Industrial 2 of 5 Minimum Reads 1 188 Industrial 2 of 5 Stitching Disable 188 Industrial 2 of 5 Character Correlation Disable 189 IATA Enable/Disable Disable 190 IATA Check Character Transmission Enable 190 Follett 2 of 5 Follett 2 of 5 Enable/Disable Interleaved 2 of 5 CIP HR Interleaved 2 of 5 CIP HR Enable/Disable Standard 2 of 5 Standard 2 of 5 Check Character Transmission Industrial 2 of 5 Code IATA Product Reference Guide 341 Standard Defaults Your Setting Page Number Parameter Default Datalogic 2 of 5 Enable/Disable Disable 191 Datalogic 2 of 5 Check Character Calculation Disable 191 Datalogic 2 of 5 Minimum Reads 2 192 Datalogic 2 of 5 Decoding Level 3 192 Datalogic 2 of 5 Length Control Variable 193 Datalogic 2 of 5 Set Length 1 6 characters 194 Datalogic 2 of 5 Set Length 2 50 195 Datalogic 2 of 5 Character Correlation Disable 196 Datalogic 2 of 5 Stitching Disable 196 Disable 197 Don’t Calculate 197 Send 198 Transmit 198 abcd/abcd 199 Don’t Require Match 199 Auto 200 Codabar Minimum Reads 2 201 Codabar Decoding Level 3 202 Codabar Length Control Variable 202 Codabar Set Length 1 3 204 Codabar Set Length 2 50 205 Codabar Interdigit Ratio 4 206 Codabar Character Correlation Disable 208 Codabar Stitching Disable 208 Disable 209 Static 209 200 msec 210 Disable 211 Datalogic 2 of 5 Codabar Codabar Enable/Disable Codabar Check Character Calculation Codabar Check Character Transmission Codabar Start/Stop Character Transmission Codabar Start/Stop Character Set Codabar Start/Stop Character Match Codabar Quiet Zones ABC Codabar ABC Codabar Enable/Disable ABC Codabar Concatenation Mode ABC Codabar Dynamic Concatenation Timeout ABC Codabar Force Concatenation 342 Gryphon™ I GD 4100/GM 4100/GBT4100/L GD 4300 Standard Defaults Parameter Default Your Setting Page Number Code 11 Code 11 Enable/Disable Disable 212 Check C and K 212 Send 213 Code 11 Minimum Reads 2 213 Code 11 Length Control Variable 214 Code 11 Set Length 1 4 215 Code 11 Set Length 2 50 216 Code 11 Interdigit Ratio 4 217 Code 11 Decoding Level 3 219 Code 11 Character Correlation Disable 220 Code 11 Stitching Disable 220 GS1 DataBar™ Omnidirectional Enable/Disable Disable 221 GS1 DataBar™ Omnidirectional GS1-128 Emulation Disable 221 1 222 GS1 DataBar™ Expanded Enable/Disable Disable 223 GS1 DataBar™ Expanded GS1-128 Emulation Disable 223 GS1 DataBar™ Expanded Minimum Reads 1 224 GS1 DataBar™ Expanded Length Control Variable 224 GS1 DataBar™ Expanded Set Length 1 1 225 GS1 DataBar™ Expanded Set Length 2 74 226 GS1 DataBar™ Limited Enable/Disable Disable 227 GS1 DataBar™ Limited GS1-128 Emulation Disable 227 1 228 Disable 229 Enable Check C and K 229 Code 93 Check Character Transmission Disable 230 Code 93 Length Control Variable 230 Code 11 Check Character Calculation Code 11 Check Character Transmission GS1 DataBar™ Omnidirectional GS1 DataBar™ Omnidirectional Minimum Reads GS1 DataBar™ Expanded GS1 DataBar™ Limited GS1 DataBar™ Limited Minimum Reads Code 93 Code 93 Enable/Disable Code 93 Check Character Calculation Product Reference Guide 343 Standard Defaults Parameter Default Your Setting Page Number Code 93 Set Length 1 1 231 Code 93 Set Length 2 50 232 Code 93 Minimum Reads 1 233 Code 93 Decoding Level 3 234 Auto 235 Code 93 Stitching Enable 236 Code 93 Character Correlation Disable 236 Disable 237 Enable Mod10 237 MSI Check Character Transmission Enable 238 MSI Length Control Variable 239 MSI Set Length 1 1 239 MSI Set Length 2 50 240 MSI Minimum Reads 4 241 MSI Decoding Level 3 242 Disable 243 Enable Plessey std. check char. verification 244 Plessey Check Character Transmission Enable 244 Plessey Length Control Variable 245 Plessey Set Length 1 1 246 Plessey Set Length 2 50 247 Plessey Minimum Reads 4 248 Plessey Decoding Level 3 249 Plessey Stitching Disable 250 Plessey Character Correlation Disable 250 Disable 251 Send 251 Enable 252 Code 93 Quiet Zones MSI MSI Enable/Disable MSI Check Character Calculation Plessey Plessey Enable/Disable Plessey Check Character Calculation Code 4 Code 4 Enable/Disable Code 4 Check Character Transmission Code 4 Hex to Decimal Conversion 344 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Standard Defaults Parameter Default Your Setting Page Number Code 5 Code 5 Enable/Disable Disable 252 Send 253 Enable 253 Code 4 and 5 Decoding Level 3 254 Code 4 and Code 5 Minimum Reads 1 255 Enable 259 Low 259 Beep Duration 80 msec 260 Beep Volume High 261 Disconnect Beep Enable 261 Base Station Beep Enable 262 Leash Alarm Disable 262 Automatic Configuration Update Enable 264 Automatic Flash Update Disable 265 30 minutes 266 Disable 268 No Delay 269 Unlink label required 270 Do not include 270 No Delimiter Character 271 2 seconds 272 ACK from cradle 272 Code 5 Check Character Transmission Code 5 Hex to Decimal Conversion Code 4 and 5 Common Configuration Items WIRELESS Features Good Transmission Beep Beep Frequency Powerdown Timeout Batch Mode RF Batch Mode Transmit Delay Direct Radio AutoLink Source Radio Address Transmission Source Radio Address Delimiter Character Features for Star Models Only STAR Radio Protocol Timeout STAR Radio Transmit Mode Display (STAR model only) - Contrast 274 - Font Size Small 274 - Backlight Off 275 Local Echo mode 275 8 seconds 276 - Display Mode - Display Timeout Product Reference Guide 345 Standard Defaults Parameter Keypad Select Default Your Setting Page Number 3C3D3E 278 Disable 280 Select PIN Code Length Select 4-character BT PIN Code 281 Set PIN Code 31323334 = Default PIN Code is 1234 281 Use Static PIN Code 282 BT HID ALT Mode Disable 282 BT HID Send Unkown ASCII Char Disable 283 BT Poll Rate 20 ms 284 Laser Scan Angle 47 degrees 288 Laser Idle Mode Disable 288 Bi-Directional Read Decoding Enable 289 Always On Scan Mode Timeout 5 Hours 290 Bluetooth-Only Features BT Security Mode BT HID Variable PIN Code Laser Features 346 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Appendix C Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types. 1D Bar Codes UPC-A EAN-13 978033029095 Code 39 Code 128 Code 128 Interleaved 2 of 5 Product Reference Guide 347 Sample Bar Codes Sample Bar Codes — continued Code 32 Codabar 13579 Code 93 Code 11 123456789 348 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Sample Bar Codes GS1 DataBar™ (RSS) GS1 DataBar™ variants must be enabled to read the bar codes below (see GS1 DataBar™ Omnidirectional on page 221). GS1 DataBar™ Expanded Stacked 10293847560192837465019283746029478450366523 GS1 DataBar™ Expanded 1234890hjio9900mnb GS1 DataBar™ Limited 08672345650916 GS1 DataBar™-14 GS1 DataBar™ Omnidirectional Truncated 55432198673467 GS1 DataBar™ Omnidirectional Stacked 90876523412674 GS1 DataBar™ Omnidirectional Stacked 78123465709811 Product Reference Guide 349 Sample Bar Codes NOTES 350 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Appendix D Keypad Use the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad. 0 1 2 3 4 5 Product Reference Guide 351 Keypad 6 7 8 9 HID Variable PIN Code Cancel an incomplete HID Variable PIN Code Exit HID Variable PIN Code 352 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Keypad A B C D E F Product Reference Guide 353 Keypad NOTES 354 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Appendix E Scancode Tables Control Character Emulation Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables. These apply to Wedge and USB Keyboard platforms. Control Character 00 . Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1. Control Character 01 . Characters from 00 to 0x1F are sent as control character Ctrl+Capital Key, special keys are located from 0x80 to 0xA1. Control Character 02 . Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table (Microsoft Windows Codepage 1252 — See page 362.) Single Press and Release Keys In the following tables, Ar↓ means Alt right pressed and Ar↑ means Alt right released and so on. Definitions for other keys are Al (Alt left ), Cr (Control Right ) Cl (Control Left ) Sh (shift). This method can be used for combining Alt, Control or Shift with other keys. Example: Consider a Control character set to 00. If AltRight+A is required before sending a label to the host, it could be done by setting three Prefix keys in this way: 0x99 0x41 0x9A. Product Reference Guide 355 Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE Table 53. Scancode Set When Control Character is 00 or 01 0x 1x x0 NULL C+@ DLE C(S)+P x1 SOH C(S)+A DC1 C(S)+Q x2 STX C(S)+B DC2 C(S)+R x3 ETX C(S)+C DC3 C(S)+S x4 EOT C(S)+D DC4 C(S)+T x5 ENQ C(S)+E NAK C(S)+U X6 ACK C(S)+F SYN C(S)+V x7 BEL C(S)+G ETB C(S)+W x8 BS CAN C(S)+X x9 HT TAB EM C(S)+Y xA LF C(S)+J SUB C(S)+Z xB VT C(S)+K ESC Esc xC FF C(S)+L FS C+\ xD CR Enter GS C+] xE SO C(S)+N RS C+^ xF SI C(S)+O US C(S)+_ 2x SP ! " # $ % & ' ( ) * + , - . / 3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 4x @ A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z [ \ ] ^ _ 6x ` a b c d e f g h i j k l m n o 7x p q r s t u v w x y z { | } ~ Del 8x € Sh↓ Sh↑ Ins Ent (keyp) F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 9x F12 Home End Pg Up Pg Dwn Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Ax Cr ↑ ‘ ƒ „ … † ‡ ˆ ‰ Š ‹ Ś ‹ Œ Bx ° ± ² ³ ´ µ ¶ ¸ ¹ º » ¼ ½ ¾ ¿ Cx À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï Dx Ð Ò Ó Ô Õ Ö × Ø Ù Ú Û Ü Ý Þ ß Ex à á â ã ä å æ ç è é ê ë ì í î ï Fx ð ñ ò ó ô õ ö ÷ ø ù ú û ü ý þ ÿ · Extended characters (sky blue) are sent through dedicated keys (when available in the selected country mode) or by using an Alt Mode sequence. 356 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE — cont. Table 54. Scancode Set When Control Character is 02 0x x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Cr ↑ BS Tab S+ Tab Home F1 F2 F3 F5 ESC F7 xE xF Enter Ins Pg Up Pg Dwn 2x Space ! “ # $ % & ‘ ( ) * + , - . / 3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 4x @ A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z [ \ ] ^ _ 6x ` a b c d e f g h i j k l m n o 7x p q r s t u v w x y z { | } ~ Del 8x € ‘ ƒ „ … † ‡ ˆ ‰ Š ‹ Ś ‹ Œ 9x ‘ ’ “ ” • – — ˜ ™ š › œ ž Ÿ Ax NBSP ¡ ¢ £ ¤ ¥ ¦ § ¨ © ª « ¬ - ® ¯ Bx ° ± ² ³ ´ µ ¶ ¸ ¹ º » ¼ ½ ¾ ¿ Cx À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï Dx Ð Ò Ó Ô Õ Ö × Ø Ù Ú Û Ü Ý Þ ß Ex à á â ã ä å æ ç è é ê ë ì í î ï Fx ð ñ ò ó ô õ ö ÷ ø ù ú û ü ý þ ÿ · F4 xD 1x Product Reference Guide F6 xC Enter Keypd F8 F9 F10 357 Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode Table 55. Scancode Set When Control Character is 00 or 01 x0 x1 x2 x3 x4 x5 X6 x7 x8 0x Alt+000 Alt+001 Alt+002 Alt+003 Alt+004 Alt+005 Alt+006 Alt+007 1x Alt+016 Alt+017 Alt+018 Alt+019 Alt+020 Alt+021 Alt+022 Alt+023 Alt+024 Alt+025 Alt+026 2x A+032 A+033 A+034 A+035 A+036 A+037 A+038 A+039 A+040 A+041 A+042 3x A+048 A+049 A+050 A+051 A+052 A+053 A+054 A+055 A+056 A+057 4x A+064 A+065 A+066 A+067 A+068 A+069 A+070 A+071 A+072 5x A+080 A+081 A+082 A+083 A+084 A+085 A+086 A+087 6x A+096 A+097 A+098 A+099 A+100 A+101 A+102 7x A+112 A+113 A+114 A+115 A+116 A+117 8x € Sh↓ Sh↑ Ins Ent (keyp) 9x F12 Home End Pg Up Ax Cr ↑ A+0161 A+0162 Bx A+0176 A+0177 Cx A+0192 Dx BS x9 HT TAB xA xB Alt+010 Alt+011 ESC Esc xC xD CR Alt+012 Enter xE Xf Alt+014 Alt+015 Alt+028 Alt+029 Alt+030 Alt+031 A+043 A+044 A+045 A+046 A+047 A+058 A+059 A+060 A+061 A+062 A+063 A+073 A+074 A+075 A+076 A+077 A+078 A+079 A+088 A+089 A+090 A+091 A+092 A+093 A+094 A+095 A+103 A+104 A+105 A+106 A+107 A+108 A+109 A+110 A+111 A+118 A+119 A+120 A+121 A+122 A+123 A+124 A+125 A+126 A+127 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 Pg Dwn Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ A+0163 A+0164 A+0165 A+0166 A+0167 A+0168 A+0169 A+0170 A+0171 A+0172 A+0173 A+0174 A+0175 A+0178 A+0179 A+0180 A+0181 A+0182 A+0183 A+0184 A+0185 A+0186 A+0187 A+0188 A+0189 A+0190 A+0191 A+0193 A+0194 A+0195 A+0196 A+0197 A+0198 A+0199 A+0200 A+0201 A+0202 A+0203 A+0204 A+0205 A+0206 A+0207 A+0208 A+0209 A+0210 A+0211 A+0212 A+0213 A+0214 A+0215 A+0216 A+0217 A+0218 A+0219 A+0220 A+0221 A+0222 A+0223 Ex A+0224 A+0225 A+0226 A+0227 A+0228 A+0229 A+0230 A+0231 A+0232 A+0233 A+0234 A+0235 A+0236 A+0237 A+0238 A+0239 Fx A+0240 A+0241 A+0242 A+0243 A+0244 A+0245 A+0246 A+0247 A+0248 A+0249 A+0250 A+0251 A+052 A+0253 A+0254 A+0255 358 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — cont. Table 56. Scancode Set When Control Character is 02 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA 0x Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Cr ↑ BS Tab 1x Pg Dwn Home 2x A+032 A+033 A+034 A+035 A+036 A+037 A+038 A+039 A+040 A+041 A+042 A+043 A+044 A+045 A+046 A+047 3x A+048 A+049 A+050 A+051 A+052 A+053 A+054 A+055 A+056 A+057 A+058 A+059 A+060 A+061 A+062 A+063 4x A+064 A+065 A+066 A+067 A+068 A+069 A+070 A+071 A+072 A+073 A+074 A+075 A+076 A+077 A+078 A+079 5x A+080 A+081 A+082 A+083 A+084 A+085 A+086 A+087 A+088 A+089 A+090 A+091 A+092 A+093 A+094 A+095 6x A+096 A+097 A+098 A+099 A+100 A+101 A+102 A+103 A+104 A+105 A+106 A+107 A+108 A+109 A+110 A+111 7x A+112 A+113 A+114 A+115 A+116 A+117 A+118 A+119 A+120 A+121 A+122 A+123 A+124 A+125 A+126 A+127 8x A+0128 A+0129 A+0130 A+0131 A+0132 A+0133 A+0134 A+0135 A+0136 A+0137 A+0138 A+0139 A+0140 A+0141 A+0142 A+0143 9x A+0144 A+0145 A+0146 A+0147 A+0148 A+0149 A+0150 A+0151 A+0152 A+0153 A+0154 A+0155 A+0156 A+0157 A+0158 A+0159 Ax A+0160 A+0161 A+0162 A+0163 A+0164 A+0165 A+0166 A+0167 A+0168 A+0169 A+0170 A+0171 A+0172 A+0173 A+0174 A+0175 Bx A+0176 A+0177 A+0178 A+0179 A+0180 A+0181 A+0182 A+0183 A+0184 A+0185 A+0186 A+0187 A+0188 A+0189 A+0190 A+0191 Cx A+0192 A+0193 A+0194 A+0195 A+0196 A+0197 A+0198 A+0199 A+0200 A+0201 A+0202 A+0203 A+0204 A+0205 A+0206 A+0207 Dx A+0208 A+0209 A+0210 A+0211 A+0212 A+0213 A+0214 A+0215 A+0216 A+0217 A+0218 A+0219 A+0220 A+0221 A+0222 A+0223 Ex A+0224 A+0225 A+0226 A+0227 A+0228 A+0229 A+0230 A+0231 A+0232 A+0233 A+0234 A+0235 A+0236 A+0237 A+0238 A+0239 Fx A+0240 A+0241 A+0242 A+0243 A+0244 A+0245 A+0246 A+0247 A+0248 A+0249 A+0250 A+0251 A+052 A+0253 A+0254 A+0255 Product Reference Guide F6 F1 F2 F3 F4 F5 xB xC Enter S+ Tab Keypd ESC F7 xD xE xF Enter Ins Pg Up F8 F9 F10 359 Digital Interface Table 57. Scancode Set When Control Character is 00 or 01 0x 1x X0 NULL C+@ DLE C(S)+P x1 SOH C(S)+A DC1 C(S)+Q x2 STX C(S)+B DC2 C(S)+R x3 ETX C(S)+C DC3 C(S)+S x4 EOT C+D DC4 C(S)+T x5 ENQ C(S)+E NAK C(S)+U x6 ACK C(S)+F SYN C(S)+V x7 BEL C(S)+G ETB C(S)+W x8 BS CAN C(S)+X x9 HT TAB EM C(S)+Y xA LF C(S)+J SUB C(S)+Z xB VT C(S)+K ESC Esc xC FF C(S)+L FS C(S)+\ xD CR Enter GS C+] xE SO C(S)+N RS C(S)+^ xF SI C(S)+O US C(S)+_ 2x Space ! “ # $ % & ‘ ( ) * + , - . / 3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 4x @ A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z [ \ ] ^ _ 6x ` a b c d e f g h i j k l m n o 7x p q r s t u v w x y z { | } ~ Del Sh↓ Sh↑ Ins Ent (keyp) F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F13 F14 F15 F16 Cl ↓ Cl ↑ x4 x5 x6 x7 x8 x9 xA xB xC xD xE Cl ↓ Cl ↑ BS Tab à S+ Tab Enter Keypd Enter Ins 8x 9x F12 Table 58. Scancode Set When Control Character is 02 X0 x1 x2 x3 0x 1x F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 xF F10 2x Space ! “ # $ % & ‘ ( ) * + , - . / 3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 4x @ A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z [ \ ] ^ _ 6x ` a b c d e f g h i j k l m n o 7x p q r s t u v w x y z { | } ~ Del 360 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 IBM31xx 102-key Table 59. Scancode Set When Control Character is 00 or 01 0x 1x X0 NULL C+@ DLE C(S)+P x1 SOH C(S)+A DC1 C(S)+Q x2 STX C(S)+B DC2 C(S)+R x3 ETX C(S)+C DC3 C(S)+S x4 EOT C+D DC4 C(S)+T x5 ENQ C(S)+E NAK C(S)+U x6 ACK C(S)+F SYN C(S)+V x7 BEL C(S)+G ETB C(S)+W x8 BS CAN C(S)+X x9 HT TAB EM C(S)+Y xA LF C(S)+J SUB C(S)+Z xB VT C(S)+K ESC Esc xC FF C(S)+L FS C(S)+\ xD CR Enter GS C+] xE SO C(S)+N RS C(S)+^ xF SI C(S)+O US C(S)+_ 2x Space ! “ # $ % & ‘ ( ) * + , - . / 3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 4x @ A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z [ \ ] ^ _ 6x ‘ a B c d e f g h i j k l m n o 7x p q R s t u v w x y z { | } Sh↓ Sh↑ Ins Ent (keyp) F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 Enter Reset Insert Delete Field - Field + Enter paddle Printl Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ xC Enter Keypd xD xE xF Enter Ins Pg Up 8x 9x F12 Ax Cr ↑ Del Table 60. Scancode Set When Control Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB 0x Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Cr ↑ BS Tab S+ Tab 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space ! “ # $ % & ‘ ( ) * + , - . / 3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 4x @ A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z [ \ ] ^ _ 6x ‘ a B c d e f g h i j k l m n o 7x p q R s t u v w x y z { | } Product Reference Guide Del 361 IBM XT Table 61. Scancode Set When Control Character is 00 or 01 0x 1x X0 NULL C+@ DLE C(S)+P x1 SOH C(S)+A DC1 C(S)+Q x2 STX C(S)+B DC2 C(S)+R x3 ETX C(S)+C DC3 C(S)+S x4 EOT C+D DC4 C(S)+T x5 ENQ C(S)+E NAK C(S)+U x6 ACK C(S)+F SYN C(S)+V x7 BEL C(S)+G ETB C(S)+W x8 BS C(S)+H CAN C(S)+X x9 HT TAB EM C(S)+Y xA LF C(S)+J SUB C(S)+Z xB VT C(S)+K ESC Esc xC FF C(S)+L FS C(S)+\ xD CR Enter GS C+] xE SO C(S)+N RS C(S)+^ xF SI C(S)+O US C(S)+_ 2x Space ! “ # $ % & ‘ ( ) * + , - . / 3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 4x @ A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z [ \ ] ^ _ 6x ‘ a B c d e f g h i j k l m n o 7x p q R s t u v w x y z { | } Sh↓ Sh↑ Ins Ent (keyp) F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 Home End Pg Up Pg Dwn Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF S+ Tab Enter Keypd Enter Ins Pg Up 8x 9x F12 Ax Cr ↑ Del Table 62. Scancode Set when Control Character 02 X0 x1 x2 x3 0x Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ 1x Pg Dwn Home Cl ↑ F6 Cr ↓ F1 Cr ↑ F2 BS F3 Tab F4 F5 ESC F7 F8 F9 F10 2x Space ! “ # $ % & ‘ ( ) * + , - . / 3x 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 4x @ A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z [ \ ] ^ _ 6x ‘ a B c d e f g h i j k l m n o 7x p q R s t u v w x y z { | } 362 Del Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Scancode Tables Microsoft Windows Codepage 1252 Windows-1252 is a character encoding of the Latin alphabet, used by default in the legacy components of Microsoft Windows in English and some other Western languages. Product Reference Guide 363 Scancode Tables NOTES 364 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Index A Aladdin™ G 16 B barcodes cancel 351 numeric barcodes 351 RS-232 baud rate 65 RS-232 parameters parity 59, 177, 251, 252, 255 battery WARNINGS 15 Beeper Pitch, Good Read 97 Volume, Good Read 99 Beeper, Good Read 96 C Cable Pinouts 330 Clear to Send 291 Code 39 Format 72 Conversion, case 90 Conversion, character 90, 311 Convert to Code 128 76 Convert to Code 39 76 Coupon Control 109 CTS 291 H Handheld Scanner Host Resets 70 68 I IBM interface selection 30 IBM Standard Format 72 Idle State (wand) 75 Indications 331 Interface Cable 18 ISSN 120 K keyboard support 56 KEYBOARD WEDGE (KBW) interface selection Keyboard Wedge Connection 19 31 M D Datalogic Aladdin™ Defaults 335 Dimensions 327 Good Read, Beeper 96 Pitch 97 Volume 99 Good Read, Beeper – 96 Good Read, Beeper Pitch – 97 Good Read, Beeper Volume – 99 Green Spot 331 16 E Mixed OEM Standard + Code 39 Format 72 N numbers lock key 60 Error Codes 332 Errors 332 Product Reference Guide 365 Index P Performance Characteristics 328 Physical Characteristics 327 Pitch – Good Read, Beeper 97 Polarity (wand) 74 Prefix/Suffix 78, 305 Product Specifications 327 Programming Barcodes 16 R Read, Beeper – Good 96 Read, Beeper Pitch – Good 97 Read, Beeper Volume – Good 99 Reading Configuration Barcodes 38 Request to Send 291 RS-232 interface selection 30 RS-232 Serial Connection 18 RTS 291 S sample barcodes code 128 347 code 39 347 interleaved 2 of 5 348 Scancode Tables 355 select digits/characters 351 Serial Output 330 Signal Speed (wand) 74 366 Standard Cable Pinouts Suffix 78, 305 Symbology Conversion symbology types 347 330 76 T Table Top Scanner 68 U UPC 110 USB Connection 19 USB interface selection 30 V Volume – Good Read, Beeper 99 W Weight 327 X XON/XOFF 292 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ASCII Chart ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP ! “ # $ % & ’ ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _ 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F ‘ a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F Australia Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 [email protected] France and Benelux Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 [email protected] Germany Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 [email protected] India Datalogic Scanning India Telephone: 91- 22 - 64504739 [email protected] Italy Datalogic Scanning SpA Telephone: [39] (0) 39/62903.1 [email protected] Japan Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 [email protected] Latin America Datalogic Scanning, Inc Telephone: (305) 742-2206 [email protected] Singapore Datalogic Scanning Singapore PTE LTD Telephone: (65) 6435-1311 [email protected] Iberia Datalogic Scanning SAS Sucursal en España Telephone: 34 91 746 28 60 [email protected] United Kingdom Datalogic Scanning LTD Telephone: 44 (0) 1582 464900 [email protected] www.datalogic.com Datalogic Scanning, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 © 2011-2013 Datalogic Scanning, Inc. 820050514 (Rev G) March 2013