Download Will Not Start
Transcript
Troubleshooting Drying Tumblers Refer to Page 3 for Model Identification HIGH TEMP START LOW TEMP MED TEMP NO HEAT 25 C 1 SELECT TEMP 2 INSERT COIN 3 PUSH START 1 SELECT TEMP HIGH TEMP START LOW TEMP MED TEMP 2 INSERT COIN 3 NO HEAT PUSH START 25 C T478C T478C T477C T477C Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.comlaundry.com Part No. 70172201 November 2001 Table of Contents Introduction......................................................................................... Model Identification ............................................................................. Theory of Operation of Instant Electronic Ignition .............................. 3 3 3 Safety Information.............................................................................. 5 Cannot Perform Infrared (IR) Communication.............................. 7 Coins Ignored When Entered ............................................................ 9 Control Display ................................................................................... Door Open Light “On” ......................................................................... No Visible Display – OPL Microprocessor Models............................. No Visible Display – Power On ........................................................... 11 11 12 13 Will Not Start ...................................................................................... Electric.................................................................................................. Manual Timer................................................................................... Rotary Coin Drop............................................................................. Gas ........................................................................................................ Manual Timer................................................................................... Rotary Coin Drop............................................................................. Steam .................................................................................................... Manual Timer................................................................................... Rotary Coin Drop............................................................................. 15 15 15 16 18 18 19 21 21 22 Will Not Start/Continue Running ..................................................... 25 EDC Control ......................................................................................... 25 OPL Microprocessor Control ............................................................... 28 Will Not Run ....................................................................................... Electric.................................................................................................. Manual Timer................................................................................... Rotary Coin Drop............................................................................. Gas ........................................................................................................ Manual Timer................................................................................... Rotary Coin Drop............................................................................. Steam .................................................................................................... Manual Timer................................................................................... Rotary Coin Drop............................................................................. 31 31 31 34 37 37 39 41 41 43 Will Not Heat....................................................................................... Electric.................................................................................................. Manual Timer................................................................................... Rotary Coin Drop............................................................................. Rotary Coin Drop (with and without time delay board) ................. Electric/Gas........................................................................................... OPL Microprocessor ........................................................................ Gas ........................................................................................................ EDC Models..................................................................................... Manual Timer................................................................................... Rotary Coin Drop............................................................................. 45 45 45 47 49 51 51 54 54 56 58 © Copyright 2001, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 1 Steam .................................................................................................... EDC Models..................................................................................... Manual Timer................................................................................... OPL Microprocessor ........................................................................ Rotary Coin Drop............................................................................. 2 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 60 60 62 64 67 70172201 Introduction Model Identification Information in this manual is applicable to these tumbler models: Gas Steam/Thermal Oil Electric 25 Pound (220 Liter) DC0220SFG DC0220SRG DT0220SFG DT0220SRG JC0220SFG JC0220SRG JT0220SFG JT0220SRG SC0220SFG SC0220SRG ST0220SFG ST0220SRG DC0220SSL DT0220SSH DT0220SSL JC0220SSL JT0220SSH JT0220SSL SC0220SSL ST0220SSH ST0220SSL DC0220SEL DT0220SEL JC0220SEL JT0220SEL SC0220SEL ST0220SEL 30 Pound (270 Liter) DC0270SFG DC0270SRG DT0270SFG DT0270SRG JC0270SFG JC0270SRG JT0270SFG JT0270SRG SC0270SFG SC0270SRG ST0270SFG ST0270SRG DC0270SSL DT0270SSH DT0270SSL JC0270SSL JT0270SSH JT0270SSL SC0270SSL ST0270SSH ST0270SSL DC0270SEL DT0270SEL JC0270SEL JT0270SEL SC0270SEL ST0270SEL 30 Pound Stacked (300 Liter) DC0300DFG DC0300DRG DT0300DFG DT0300DRG JC0300DFG JC0300DRG JT0300DFG JT0300DRG NT0300DRG SC0300DFG SC0300DRG ST0300DFG ST0300DRG DC0300DSL DT0300DSH DT0300DSL JC0300DSL JT0300DSH JT0300DSL SC0300DSL ST0300DSH ST0300DSL DC0300DEL DT0300DEL JC0300DEL JT0300DEL SC0300DEL ST0300DEL 35 Pound (350 Liter) AT0350SRG DC0350SFG DC0350SRG DT0350SFG DT0350SRG JC0350SFG JC0350SRG JT0350SFG JT0350SRG SC0350SFG SC0350SRG ST0350SFG ST0350SRG AT0350SSL DC0350SSL DT0350SSH DT0350SSL JC0350SSL JT0350SSH JT0350SSL SC0350SSL ST0350SSH ST3050SSL DC0350SEL DT0350SEL JC0350SEL JT0350SEL SC0350SEL ST0350SEL Theory of Operation of Instant Electronic Ignition IMPORTANT: The Non-CE Marked Instant Electronic Ignition system will attempt to light the gas by sparking for approximately 15 seconds. If gas ignition does not take place within approximately 15 seconds, the Instant Electronic Ignition control will go into safety lockout and the valve will no longer open until Instant Electronic Ignition control is reset. To reset Instant Electronic Ignition control, remove power from control by opening and closing the tumbler door. If condition persists, check that the gas shut-off valve is in “on” position and that the gas service is properly connected. 70172201 If condition persists: 1. Check resistance of high tension lead (approximately 1000 ohms/inch), and replace if not within resistance range. 2. Check voltage present at valve. 3. Check that machine is properly grounded. 4. Check the gap between igniter and burner tube (gap should be 1/4-3/8 inch). 5. Check that burner ports are not blocked or plugged under the igniter. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 3 Safety Information Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine. DANGER DANGER indicates the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the danger is ignored. WARNING WARNING indicates the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the warning is ignored. CAUTION CAUTION indicates the presence of a hazard that will or can cause minor personal injury or property damage if the caution is ignored. IMPORTANT: The word “IMPORTANT” is used to inform the reader of specific procedures where minor machine damage will occur if the procedure is not followed. NOTE: The word “NOTE” is used to communicate installation, operation, maintenance or servicing information that is important but not hazard related. WARNING Failure to install, maintain, and/or operate this machine according to manufacturer’s instructions may result in conditions which can produce serious injury, death and/or property damage. W051 NOTE: The WARNINGS and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and carefulness are factors which CANNOT be built into this tumbler. These factors MUST BE supplied by the person(s) installing, maintaining or operating the tumbler. Always contact your dealer, distributor, service agent or the manufacturer on any problems or conditions you do not understand. Additional precautionary statements (“IMPORTANT” and “NOTE”) are followed by specific instructions. 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 5 Cannot Perform Infrared (IR) Communication Attempt to communicate with the electronic control from the micro wand. Single and stacked. Gas and electric heat. Single and three phase supply. Check the following: Is there a response of any kind from the electronic control? NO Aim micro wand closer and try again. YES Does the control respond? NO - low battery on micro wand - is the IR window covered or blocked on the control. - if needed replace the EDC control - is the IR cap properly attached to the micro wand. YES Does the electronic control display "E:OF" or "-C-"? "-C-" Communication sequence checks out. "E:OF" Check the following: - IR communication disabled by manual programming. - Is the IR window on the control covered or blocked. - if needed, change EDC board. T027D T027D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 7 Coins Ignored When Entered Single and stacked units. Gas and electric heat. Single and three phase voltage. Start coin drop diagnostic tests. Does the display on the EDC control increment properly? YES Exit diagnostic testing and reset control. (Prompting for vend price) NO Is connector H2 firmly seated in its receptacle? NO Reconnect and run diagnostic test again. NO Reconnect and run diagnostic test again. YES Is the 3 pin connector between coin drop and control connected correctly? YES Are wires exiting coin drop optical sensor cracked or broken? YES Replace coin drop. NO Replace coin drop. If problem still exists then replace the EDC control. T026D T026D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 9 Control Display Door Open Light “On” Single and stacked units. Gas and electric heat. Single and three phase supply. Is there voltage at "H4-6 on the EDC control? YES Reference voltage checks to transformer neutral. Is there voltage at the input of the secondary fuse? NO Replace EDC Control. Correct wiring between secondary fuse and transformer. YES NO Is there power supplied to the unit? NO Is there voltage to output side of secondary fuse? NO Replace secondary fuse. Plug unit in and run it. YES YES Is there voltage to input of primary fuses? NO Correct wiring between primary fuses and power supply. Is there voltage to N.O. of door switch? NO Correct wiring between N.O. and output of secondary fuse. YES YES Is there voltage to output side of the primary fuses? NO Replace primary fuse(s). With door closed is there voltage to COM of door switch? NO Check for proper function of door switch replace if necessary. YES YES Is there voltage across terminals "1" & "2" of transformer primary? NO Correct wiring between primary fuses and transformer. Is there voltage to N.O. of lint drawer switch? NO Correct wiring between N.O. on lint drawer and COM on door switch. YES YES Is there voltage across terminals "2" & "3" of transformer secondary? NO Replace transformer. Is there voltage to COM of lint drawer switch with lint panel closed? NO Check for proper operation replace if necessary. YES YES Correct wiring between "H4-6" of EDC control and COM of lint drawer switch. T028D T028D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 11 Control Display No Visible Display – OPL Microprocessor Models Gas, steam and electric heat. Single and three phase supply. NO Is there voltage supplied to the unit? Connect supply voltage and run unit. YES Is there voltage across fuse on OPL Micro? NO Replace OPL Micro. YES Note: Reference voltage to supply neutral. Replace fuse. Is there voltage to the input side of the primary fuse(s)? NO Correct wiring between primary fuse and supply. YES Is there voltage to the output side of the primary fuse(s)? NO Replace primary fuse. YES Is there voltage to primary side of the transformer terminal "1"? NO Correct wiring between transformer and primary fuse. YES Is there voltage across "1" & "4" of transformer secondary? NO Replace transformer YES Is there voltage across terminals "H3-3" & "H3-4" on OPL Micro? NO Correct wiring between OPL Micro and transformer secondary. YES T007D T007D 12 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Control Display No Visible Display – Power On Single and stacked units. Gas and electric heat. Single and three phase supply. Is there voltage across "H4-2 & H4-5" on the EDC control? YES Replace EDC Control. NO Is there voltage at the input of the secondary fuse? NO Correct wiring between secondary fuse and transformer. YES Is there power supplied to the unit? NO Plug unit in and run it. YES Is there voltage to output side of secondary fuse? NO Replace secondary fuse. YES Is there voltage to input of primary fuses? NO Correct wiring between primary fuses and power supply. Correct wiring between "H4-2" and secondary fuse. YES Is there voltage to output side of the primary fuses? NO Replace primary fuse(s). YES Is there voltage across terminals "1" & "2" of transformer primary? NO Correct wiring between primary fuse and transformer. YES Is there voltage across terminals "2" & "3" of transformer secondary? NO Replace transformer. YES T025D T025D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 13 Will Not Start Electric Manual Timer Manual Timer, with and without Time Delay Board, Single and Stacked units, Single and 3 Phase power supply. Is there power supply voltage coming to the tumbler? NO Connect power and run the cycle. YES Is there voltage at the primary side of the transformer at terminals 1 and 2? NO Change the primary Still no voltage fuse to the transformer. Correct wiring between power supply and transformer. For stacked units. YES Correct wiring between upper and lower pocket. Is there voltage at the secondary side of the transformer at terminal 2 and 3? NO Replace the transformer. NO Change the secondary fuse. YES Is there voltage to the output side of the secondary fuse? YES NOTE: White wires are transformer "neutral" Is there voltage to the "N.O." terminal of the door switch? YES With door closed Is there voltage at "COM" of the door switch? With lint panel closed is there votlage to "N.O." terminal of the liint panel switch? YES NO NO Correct the wiring between the door switch and the secondary fuse. NO Correct the wiring between the secondary fuse and the transformer. NO Is there voltage to the "COM" of the lint panel switch? YES NO Correct wiring between lint panel switch and door switch. Check for proper operation, replace the door switch if necessary. Refer to NO MOTOR RUN (run circuit.) YES Replace lint panel switch. T050D T050D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 15 Will Not Start Electric Rotary Coin Drop (Sheet 1 of 2) Coin Drop with and without Time Delay Boards. Single and Stacked units. Single and 3 phase power supply. Is there power supply voltage coming to the unit? NO Connect power to the unit and run cycle. Is there voltage across coinmeter timer motor? NO Correct wiring between coinmeter timer motor and COM on switch "A". YES YES Is the primary fuse good? Is there voltage at the primary side of the transformer at terminals "1" & "2"? NO NO Replace fuse and run machine. Does the coinmeter timer motor advance? YES Is there voltage at the secondary side of the transformer at terminal "2" and "3"? NO Is there voltage at N.O. terminal of the door switch? Replace the transformer. Is the secondary fuse good? NO YES Correct wiring between secondary of transformer and fuse. YES Note: Reference voltage to transformer neutral. (White wire) Is there voltage to "N.C." terminal of switch "A" on rotary coin drop? NO Correct wiring between N.O on door switch and COM on switch"A". YES YES Is there voltage to the output side of the secondary fuse? Replace coinmeter timer motor. YES Correct wiring between transformer and power supply. YES NO NO Correct wiring between rotary coin drop and secondary fuse. NO Replace fuse and run machine. With the door closed is there voltage across the door switch? YES Check door switch for proper operation, replace if necessary. NO Is there voltage to the N.O. terminal of the lint panel switch? NO Correct wiring between N.O. on the lint panel switch and COM of door switch. YES YES Is the unit equipped with time delay boards? YES Continued on next page at step 1. With the lint panel closed is there voltage across the lint panel switch? YES Check lint panel switch for proper operation and replace if necessary. NO NO Note: The following checks are made with the vend price satisfied. Is there voltage on the "COM" terminal of switch "A"? NO Continued on next page at step 2. Replace switch "A". Step 3 continuation. YES T075D T075D 16 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Start Electric Rotary Coin Drop (Sheet 2 of 2) STEP 1 STEP 2 Is there voltage to "H1-2" on TMR1 board? YES NO Correct wiring between "H1-2" and output of secondary fuse. Is there voltage at "2A" of the start switch? YES Note: Following tests are conducted with vend price satisfied. With vend price satisfied is there voltage across "N.C." & COM of switch "A"? YES Correct wiring between "2A" of start switch and COM of lint panel switch. NO Replace Switch "A" 3 phase Does the unit have single phase or three phase power supply? NO Single phase Is there voltage across the timer motor? NO Correct wiring between timer motor and COM on switch "A" Is there voltage at terminal "7" of the motor relay? YES Does Coinmeter Timer Motor advance? NO Replace Timer Motor. NO Correct wiring between "H1-6" and COM on switch "A" YES Correct wiring between "7" of motor relay and COM of lint panel switch. NO Refer to NO MOTOR RUN (run circuit). YES Is there voltage across "H1-6" & "H1-8" of TMR1? YES Is there voltage at terminal "14" of the motor control relay? NO Correct wiring to terminal "14" of motor control relay. YES Is there voltage across "H1-2" & "H1-3" of TMR1"? YES Replace TMR1. Refer to NO MOTOR RUN (Run Circuit). NO Is there voltage to N.O. of door switch? NO Correct wiring between N.O. of door switch and "H1-3" of TMR1. YES Continue at step 3 on previous page. T076D T076D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 17 Will Not Start Gas Manual Timer No motor run (start circuit) Manual Tumblers. Single and stacked units with and without time delay. GAS UNITS Is there power supply voltage coming to the tumbler? NO Connect power and run the cycle. NO Change the primary Still no voltage fuse to the transformer. YES Is there voltage at the primary side of the transformer at terminals 1 and 2? YES Correct wiring between power supply and transformer. For stacked units. Correct wiring between upper and lower pocket. Is there voltage at the secondary side of the transformer at terminal 2 and 3? NO Replace the transformer. NO Change the secondary fuse. YES Is there voltage to the output side of the secondary fuse? YES NOTE: White wires are transformer "neutral" Is there voltage to the input side of the door switch? YES Is there voltage to the output side of the door switch? Correct the wiring between the door switch and the secondary fuse. Is there voltage to the output side of the lint panel switch? YES NO NO NO Correct the wiring between the secondary fuse and the transformer. NO Is there voltage to the input side of the lint panel switch? YES NO Correct wiring between lint panel switch and door switch. Replace the door switch. Refer to NO MOTOR RUN (run circuit). YES Replace lint panel switch. T041D T041D 18 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Start Gas Rotary Coin Drop (Sheet 1 of 2) Single & Stacked Tumblers with and without time delay Gas units. Is there power supply voltage coming to the unit? NO Connect power to the unit and run cycle. Is there voltage across coinmeter timer motor? NO Correct wiring between coinmeter timer motor and COM on switch "A". YES YES Is the primary fuse good? Is there voltage at the primary side of the transformer at terminals "1" & "2"? NO NO Replace fuse and run machine. Does the coinmeter timer motor advance? YES Is there voltage at the secondary side of the transformer at terminal "2" and "3"? NO Is there voltage at N.O. terminal of the door switch? Replace the transformer. NO Correct wiring between N.O on door switch and COM on switch"A". YES YES Is the secondary fuse good? Is there voltage to the output side of the secondary fuse? Replace coinmeter timer motor. YES Correct wiring between transformer and power supply. YES NO NO YES Correct wiring between secondary of transformer and fuse. YES Note: Reference voltage to transformer neutral. (White wire) Is there voltage to Correct wiring NO "N.C." terminal of between rotary coin switch "A" on rotary drop and secondary coin drop? fuse. NO Replace fuse and run machine. With the door closed is there voltage across the door switch? YES Check door switch for proper operation, replace if necessary. NO Is there voltage to the N.O. terminal of the lint panel switch? NO Correct wiring between N.O. on the lint panel switch and COM of door switch. YES YES Is the unit equipped with time delay boards? YES Continued on next page at step 1. With the lint panel closed is there voltage across the lint panel switch? YES Check lint panel switch for proper operation and replace if necessary. NO NO Note: The following checks are made with the vend price satisfied. Is there voltage on the COM terminal of switch "A"? NO Continued on next page at step 2. Replace switch "A". Step 3 continuation. T086D YES T086D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 19 Will Not Start Gas Rotary Coin Drop (Sheet 2 of 2) STEP 2 STEP 1 Is there voltage to "H1-2" on TMR1 board? YES NO Correct wiring between "H1-2" and output of secondary fuse. YES NO Correct wiring between 2A of start switch and COM of lint panel switch. YES Note: Following tests are conducted with vend price satisfied. With vend price satisfied is there voltage across "N.C." & COM of switch "A"? Is there voltage at 2A of the start switch? Replace Switch "A" Is there voltage at terminal 7 of the motor relay? NO Correct wiring between 7 of motor relay and COM of lint panel switch. NO YES Is there voltage across the timer motor? NO Correct wiring between timer motor and COM on switch "A" Refer to NO MOTOR RUN (run circuit). YES Does Coinmeter Timer Motor advance? NO Replace Timer Motor. NO Correct wiring between "H1-6" and COM on switch "A" YES Is there voltage across "H1-6" & "H1-8" of TMR1? YES Is there voltage across "H1-2" & "H1-3" of TMR1? YES Replace TMR1. NO Is there voltage to N.O. of door switch? NO Correct wiring between N.O. of door switch and "H1-3" of TMR1. YES Continue at step 3 on previous page. T087D T087D 20 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Start Steam Manual Timer Single and stacked units with and without time delay boards. Steam Heat. Is there power supply voltage coming to the tumbler? NO Connect power and run the cycle. NO Change the primary Still no voltage fuse to the transformer YES Is there voltage at the primary side of the transformer at terminals 1 and 2? YES Correct wiring between power supply and transformer. For stacked units. Correct wiring between upper and lower pocket. Is there voltage at the secondary side of the transformer at terminal 2 and 3? NO Replace the transformer. NO Change the secondary fuse. YES Is there voltage to the output side of the secondary fuse? YES NOTE: White wires are transformer "neutral" Is there voltage to the N.O. terminal of the door switch? YES Is there voltage to the COM terminal of the door switch? Correct the wiring between the door switch and the secondary fuse Is there voltage to the N.O. terminal of the lint panel switch? YES NO NO NO Correct the wiring between the secondary fuse and the transformer. NO Is there voltage to the COM terminal of the lint panel switch? YES NO Correct wiring between lint panel switch and door switch. Replace the door switch. Refer to NO MOTOR RUN (run circuit) . YES Replace lint panel switch. T016D T016D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 21 Will Not Start Steam Rotary Coin Drop (Sheet 1 of 2) Single & Stacked Tumblers with and without time delay Steam units. Is there power supply to the unit? NO Connect power to the unit and run cycle. Is there voltage across coinmeter timer motor? NO Correct wiring between coinmeter timer motor and COM on switch "A". YES YES Is the primary fuse good? Is there voltage at the primary side of the transformer at terminals "1" & "2"? NO NO Replace fuse and run machine. Does the coinmeter timer motor advance? YES Correct wiring between transformer and power supply. YES Is there voltage at the secondary side of the transformer at terminal "2" and "3"? NO Replace coinmeter timer motor. YES Is there voltage at N.O. terminal of the door switch? Replace the transformer. NO Correct wiring between N.O on door switch and COM on switch"A". YES YES Is the secondary fuse good? Is there voltage to the output side of the secondary fuse? NO NO YES Correct wiring between secondary of transformer and fuse. YES Note: Reference voltage to transformer neutral. (White wire) Correct wiring Is there voltage to NO between rotary coin "N.C." terminal of drop and secondary switch "A" on rotary fuse. coin drop? NO Replace fuse and run machine. With the door closed is there voltage across the door switch? YES Check door switch for proper operation, replace if necessary. NO Is there voltage to the N.O. terminal of the lint panel switch? NO Correct wiring between N.O. on the lint panel switch and COM of door switch. YES YES Is the unit equipped with time delay boards? YES Continued on next page column 1. With the lint panel closed is there voltage across the lint panel switch? YES Check lint panel switch for proper operation and replace if necessary. NO NO Note: The following checks are made with the vend price satisfied. Is there voltage on the COM terminal of switch "A"? NO Continued on next page column 2. Replace switch "A". Step 3 continuation. YES T062D T062D 22 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Start Steam Rotary Coin Drop (Sheet 2 of 2) COLUMN 1 COLUMN 2 Is there voltage to "H1-2" on TMR1 board? YES NO Correct wiring between "H1-2" and output of secondary fuse. YES NO Correct wiring between "2A" of start switch and COM of lint panel switch. YES Note: Following tests are conducted with vend price satisfied. With vend price satisfied is there voltage across "N.C." & COM of switch "A"? Is there voltage at "2A" of the start switch? Replace Switch "A" Is there voltage at terminal "7" of the motor relay? NO Correct wiring between "7" of motor relay and COM of lint panel switch. NO YES Is there voltage across the timer motor? NO Correct wiring between timer motor and COM on switch "A" Refer to NO MOTOR RUN (run circuit). YES Does Coinmeter Timer Motor advance? NO Replace Timer Motor. NO Correct wiring between "H1-6" and COM on switch "A" YES Is there voltage across "H1-6" & "H1-8" of TMR1? YES Is there voltage across "H1-2" & "H1-3" of TMR1"? YES Replace TMR1. NO Is there voltage to N.O. of door switch? NO Correct wiring between N.O. of door switch and "H1-3" of TMR1. YES Continue at step 3 on previous page. T063D T063D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 23 Will Not Start/Continue Running EDC Control (Sheet 1 of 3) Note: test conducted with vend price satisfied and start button pressed. Is there voltage at "H4-4" on the EDC control to transformer neutral? YES Single and stacked units. Gas, electric and steam heat. Single and three phase supply. Continued on next page. Is there voltage at the input of the secondary fuse? NO Correct wiring between secondary fuse and transformer. YES NO Is there power supplied to the unit? NO Plug unit in and run it. Is there voltage to output side of secondary fuse? NO Replace secondary fuse. YES YES Is there voltage to N.O. of door switch? Is there voltage to input of primary fuse(s)? NO Correct wiring between primary fuse(s) and power supply. YES Correct wiring between N.O. and output of secondary fuse. YES With door closed is there voltage to COM of door switch? Is there voltage to output side of the primary fuse(s)? NO NO Check for proper function of door switch replace if necessary. YES NO Replace primary fuse. Is there voltage to N.O. of lint drawer switch? YES NO Correct wiring between N.O. on lint drawer and COM on door switch. YES Is there voltage across terminals "1" & "2" of transformer primary? NO Correct wiring between primary fuse and transformer. Is there voltage to COM of lint drawer switch with lint panel closed? NO Check for proper operation replace if necessary. YES YES Is there voltage across terminals "2" & "3" of transformer secondary? YES NO Replace transformer. Is there voltage at "H4-1" on the EDC control board? NO Correct wiring between "H4-1" and COM of lint drawer switch. YES Replace EDC Control. T029D T029D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 25 Will Not Start/Continue Running EDC Control (Sheet 2 of 3) Note: Tests conducted with vend price satisfied and start button pressed. Is there voltage on "B" terminal of motor control relay? Is there voltage across terminals "1" & "4" of the fan motor? NO Correct wiring between "B" and "H4-4". NO Correct wiring between fan motor and motor control relay. YES YES Does the fan motor run? 3 phase. See note on next page Is the unit equipped with single phase or three phase power? Replace fan motor. YES Is unit equipped with single phase or three phase power supply? Single phase Is there voltage to terminal "5" of the motor control relay? NO NO Correct wiring between terminal "5" and power supply. Three phase. See note on next page. Is there supply voltage to L2 & L3 of motor control relay? YES Single phase NO Correct wiring between L2, L3 and supply. YES Replace motor control relay. YES Is there voltage to terminal "8" of motor control relay? NO Replace motor control relay. Is there voltage across terminals L2 & T2 and L3 & T3? YES NO Is there supply voltage to L1 and L2 of the motor control relay? NO Correct wiring between L1, L2 and power supply. Is there voltage at terminal "6" of motor control relay? YES NO Correct wiring between terminal "6" of motor control relay and supply. YES Is there votlage across L1 & T1 and L2 & T2? YES Replace motor control relay. Is there voltage at terminal "9" of motor control relay? NO Replace motor control relay. NO YES Continued on next page. T030D T030D 26 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Start/Continue Running EDC Control (Sheet 3 of 3) Is there voltage across terminals "1" & "4" of cylinder motor? NO Correct wiring between cylinder motor and motor control relay. YES Does the cylinder motor run? NO Replace cylinder motor. YES Motors are operational. Note: For high voltage three phase supply (380 volts or higher), the cylinder and fan motors are supplied by L1, L2, L3 through the motor relay terminals T1, T2, T3. Make the appropriate adjustments when doing voltage checks. T031D T031D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 27 Will Not Start/Continue Running OPL Microprocessor Control (Sheet 1 of 3) Gas, steam and electric heat. Single and three phase supply. Reference voltage to supply neutral. Is power supplied to unit? NO Connect supply and run unit. Is there voltage to output of secondary fuse? NO Replace secondary fuse. YES YES Is there voltage to input of primary fuse(s)? NO Correct wiring between primary fuse and supply. Is there voltage to "N.O." terminal of door switch? NO Correct wiring between "N.O." terminal of door switch and secondary fuse. YES YES Is there voltage to output of primary fuse(s)? NO Change primary fuse. With door closed is there voltage to "COM" of door switch? NO Check for proper operation, replace door switch if necessary. YES YES Is there voltage across terminals "1" & "2" on primary of transformer? NO Correct wiring between transformer and primary fuse. Is there voltage to "N.O." of lint panel switch? NO Correct wiring between "N.O." of lint panel switch and "COM" of door switch. YES YES Is there voltage across terminals "2" & "3" of transformer secondary? NO Replace transformer. Is there voltage to "COM" of lint panel switch with lint panel closed? NO Check for proper operation and replace lint panel switch if necessary. YES YES Note: Reference voltage to transformer secondary neutral terminal "3". Is there voltage to input of secondary fuse? YES NO Correct wiring between secondary fuse and transformer. Is there voltage at terminal "8" of OPL Micro? NO Correct wiring between terminal "8" of OPL Micro and "COM" of lint panel switch. YES Continued on next page. T099D T099D 28 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Start/Continue Running OPL Microprocessor Control (Sheet 2 of 3) OPL Start - Run Circuitry continued. Tests conducted with cycle selected and start key pad activated. Is there voltage at terminal "7" on OPL Micro? Is there voltage across terminals "1" & "4" of fan motor? NO Correct wiring between fan motor and motor control relay. NO Replace OPL Micro. YES YES Is there voltage across terminals "B" & "A" of motor control relay for "OM" model and terminals "0" & "1" for "RM" models? Does the fan motor run? NO NO Replace fan motor. Correct wiring to motor control relay. YES YES Does the unit have reversing capabilities? Is unit supplied with single phase or three phase power? See cylinder rotation. Either forward or reverse. YES Single phase NO Three phase. See note on next page. Reference voltage to supply neutral. Is there voltage to L1 and L2 of the motor control relay? NO Single phase Does the unit have single phase or three phase supply? Correct wiring between L1, L2 and power supply. Three phase. See note on next page. Is there voltage to L2 and L3 on the motor control relay? YES Is ther voltage to T1 and T2 of the motor control relay? NO Replace motor control relay. Is there voltage at terminal "5" on the motor control relay for "OM" models and terminal "2" for "RM" models? NO Correct wiring between motor control relay and power supply. Correct wiring between L2, L3 and power supply. NO Replace motor control relay. YES Is there voltage to T2 and T3 on the motor control relay? YES NO Is there voltage to terminal "6" of motor control relay? Correct wiring between terminal "6" motor control relay and supply voltage. NO YES YES Is there voltage across terminals "5" & "8" of the motor control relay for "OM" models and terminals "2" & "4" for "RM" models? NO YES Replace motor control relay. Is there voltage across terminals "6" & "9" of motor control relay? NO YES Replace motor control relay. Continued on next page. T008D T008D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 29 Will Not Start/Continue Running OPL Microprocessor Control (Sheet 3 of 3) Is there voltage across terminals "1" & "4" of the cylinder motor? NO Correct the wiring between the cylinder motor and control relay. YES Does the cylinder motor run? NO Replace cylinder motor. YES Unit operational. NOTE: For three phase high voltage (380volts or higher), the cylinder and fan motors are supplied L1, L2, L3 through the motor relay terminals T1, T2, T3. Make the appropriate voltage checks while doing trouble shooting. T009D T009D 30 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Run Electric Manual Timer (Sheet 1 of 3) With and without Time Delay Boards. Single and Stacked units. Single and 3 phase power supply. Is there voltage at terminal "C" on the drying timer? NO Correct wiring between drying timer and lint panel switch. NO Is the unit equipped with a Time Delay Board? YES YES NOTE: make sure drying timer is in the "on" position. Is there voltage at terminal "B" on the drying timer? NO Is there voltage across "H1-6" & "H1-8" on TMR1? Replace drying timer. NO Correct wiring to TMR1. NO Check for proper operation of Air Flow Switch. YES Replace Time Delay Board. YES YES ** Is there voltage across terminals "7" and "8" of CR1 relay? NO Is there voltage across terminals "H1-4" & "H1-8" on TMR2? Correct the wiring between CR1 relay and terminal "B" on drying timer. YES YES ** Is there voltage across terminal "3" and "5" of CR1 relay? YES Is there voltage across "DOB" contacts on TMR2? Replace CR1 relay. NO NO NOTE: This test to be made with Push to Start Switch pressed in. Is there voltage across terminals "2A" & "1A" of push to start switch? YES ** Is there voltage across terminals "7" & "8" of CR2 Relay? Replace Push to Start Switch. NO Correct wiring between CR2 Relay and Air Flow Switch. YES NO NOTE: The "N.O." contact is closed in the rest position due to the physical mounting of the switch. ** Is there voltage across "COM" and "N.O." of the air flow switch? YES Is there voltage across terminals "5" & "3" on the CR2 Relay? Adjust the air flow switch or replace if inoperative. YES Replace CR2 Relay. NO NO CONTINUED ON NEXT PAGE. YES ** Is there voltage across coils "B" & "A" of the Motor Control Relay? ** Tested with the start switch pressed in. NO Correct wiring between Motor Control Relay and Air Flow Switch. T051D T051D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 31 Will Not Run Electric Manual Timer (Sheet 2 of 3) Is this a single phase or 3 phase unit? 3 phase Is there voltage across terminals "14" & "13" of motor control relay? Single phase ** Is there voltage across terminal "7" & "4" of the Motor Control Relay? YES Replace motor control relay. NO Correct wiring between "L1" and power supply. NO YES Replace Motor Control Relay. NO Is there voltage to "L1" of motor control relay? YES Is there voltage at terminal "5" on the motor control relay to to supply neutral? NO Correct wiring between terminal "5" and supply voltage. Is there voltage to "L2" of motor control relay? NO Correct wiring between "L2" and power supply. YES YES Is there voltage across terminal "5" & "8" of the motor control relay? YES Replace motor control relay. Is there voltage across "L1" to "T1" and "L2" to "T2" on the motor control relay? YES Replace motor control relay. NO NO Is there voltage across terminals "1" & "4" of Fan Motor? NO Correct wiring between Fan Motor and contact "8" on the Motor Control Relay. YES Note: Only for non time delay machines Is there voltage across terminals "3" & "5" of the fan motor centrifugal switch with the fan motor running? YES Replace Fan Motor. NO Does the Fan Motor Run? NO Replace the Fan Motor. Continued on next page. YES ** Tested with the start switch pressed in. T052D T052D 32 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Run Electric Manual Timer (Sheet 3 of 3) Three phase. Is unit single phase or 3 phase? Is there voltage to "L2" on motor control relay? NO Correct wiring between terminal "6" and power supply. Is there voltage to "L3" on motor control relay? YES Is there voltage across terminal "6" & "9" of the motor control relay? NO Correct wiring between motor control relay and supply. YES YES Replace motor control relay. NO Is there voltage at terminals "1" & "4" of the Cylinder Motor? Correct wiring between motor control relay and supply. YES Single phase. Is there voltage to terminal "6" on the motor control relay? NO Is there voltage across "L2 to T2" and "L3 to T3" on the motor control relay? YES Replace motor control relay. NO NO Correct wiring between Cylinder Motor and contact "9" on the Motor Control Relay. YES Does the Cylinder Motor Run? NO Replace the Cylinder Motor. YES The Cylinder and Fan Motors are operational. T053D T053D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 33 Will Not Run Electric Rotary Coin Drop (Sheet 1 of 3) Tumblers Single & Stack with and without time delay. Single and Three phase power. ** Is there voltage across terminals "7" & "8" of CR2 Relay? ** Tested with vend price satisfied and with start switch pressed in. ** Is there voltage across terminals "2A" & "1A" of push to start switch? YES Replace Push to Start Switch. NO Correct wiring between CR2 Relay and Air Flow Switch. YES ** Is there voltage across terminals "5" & "3" on the CR2 Relay? NO Note: Reference voltage to transformer neutral. Is there voltage to COM of the Air Flow Switch? NO Correct wiring between COM of Air Flow Switch and "1A" on Start Switch. YES NO ** Is there voltage across the coil of the Motor Control Relay? YES NOTE: The N.O. contact is closed in the rest position due to the physical mounting of the switch. ** Is there voltage across COM and "N.O." of the air flow switch? YES Replace CR2 Relay. NO Correct wiring between Motor Control Relay and Air Flow Switch. YES Replace inoperative switch or correct air flow vane operation. Is unit Single phase or Three phase? Three phase please see not. Continued on next page COLUMN 2. NO Single Phase Is the unit equipped with a Time Delay Board? NO ** Is there voltage across terminal "7" & "4" of the Motor Control Relay? YES Replace Motor Control Relay. YES NO ** Is there voltage across terminals "H1-4" & "H1-8" on TMR2? NO Check for proper operation of Air Flow Switch and check wiring. Is there voltage at terminal "5" on the motor control relay? NO Correct wiring between terminal "5" and supply voltage. YES YES ** Is there voltage across "DOB" contacts on TMR2? YES Replace Time Delay Board. Continued on next page COLUMN 1. NO ** Tested with the start switch pressed in. T072D T072D 34 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Run Electric Rotary Coin Drop (Sheet 2 of 3) COLUMN 2 COLUMN 1 Is there voltage across terminal "5" & "8" of the motor control relay? YES Is there voltage across terminal "14" & "13" of motor control relay? Replace motor control relay. YES Replace motor control relay. NO Correct wiring between "L1", "L2" and supply. NO Replace motor control relay. NO NO Is there voltage across terminals "1" & "4" of Fan Motor? Correct wiring between Fan Motor and contact "8" on the Motor Control Relay. NO Is there voltage to "L1" & "L2" terminals on motor control relay? YES YES YES Does the Fan Motor Run? NO Is there voltage to "T1" & "T2" terminals on motor control relay? Replace the Fan Motor. YES For units without Time Delay Boards. Is there voltage across terminals "3" & "5" of the fan motor centrifugal switch with the fan motor running? YES NOTE: For Hi voltage three phase supply (380volts or higher), the cylinder and fan motor are supplied "L1", "L2", "L3" through the motor relay terminals "T1", "T2", "T3". Make the appropriate adjustments when doing trouble shooting. Replace Fan Motor. Is there voltage to "L2" & "L3" terminals on motor control relay? NO Is the machine supplied with single phase or three phase power? Three Phase Please see note. NO Correct wiring between supply and "L2" & "L3" terminals. YES Is there voltage across "L2" to "T2" and "L3" to "T3"? YES Replace motor control relay. NO Replace cylinder motor. Single Phase NO Is there voltage to terminal "6" on the motor control relay? YES Continued on next page COLUMN 1. NO Correct wiring between terminal "6" and power supply. Does the cylinder motor run? YES CYLINDER AND FAN MOTORS ARE OPERATIONAL. T073D T073D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 35 Will Not Run Electric Rotary Coin Drop (Sheet 3 of 3) COLUMN 1 Is there voltage across terminals "6" & "9" of motor control relay? YES Replace motor control relay. NO Is there voltage at terminals "1" & "4" of the Cylinder Motor? NO Correct wiring between Cylinder Motor and contact "9" on the Motor Control Relay. YES Does the Cylinder Motor Run? NO Replace the Cylinder Motor. YES The Cylinder and Fan Motors are operational. T074D T074D 36 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Run Gas Manual Timer (Sheet 1 of 2) No motor run (run circuit) Manual Tumblers Single and stacked units with and without Time Delay Boards. GAS UNIT. Is there voltage at terminal “c” on the drying timer? NO Correct wiring between drying timer and lint panel switch. NO YES Is the unit equipped with a Time Delay Board? YES NOTE: make sure drying timer is in the “on” position. Is there voltage at terminal “b” on the drying timer? NO Is there voltage across “H1-6” & “H1-8” on TMR1? Replace drying timer. NO Correct wiring to TMR1. NO Check for proper operation of Airflow Switch. YES Replace Time Delay Board. YES YES ** Is there voltage across terminals “7” and “8” of CR1 relay? NO Is there voltage across terminals “H1-4” & “H1-8” on TMR2? Correct the wiring between CR1 relay and terminal “b” on drying timer. YES YES ** Is there voltage across terminal “3” and “5” of CR1 relay? YES Is there voltage across "DOB" contacts on TMR2? Replace CR1 relay. NO NO NOTE: This test to be made with Push to Start Switch pressed in. Is there voltage across terminals “2A” & “1A” of push to Start switch? YES ** Is there voltage across terminals “7” & “8” of CR2 Relay? Replace Push to Start Switch. NO Correct wiring between CR2 Relay and Airflow Switch. YES NO NOTE: The N.O. contact is closed in the rest position due to the physical mounting of the switch. ** Is there voltage across “COM” and “N.O.” of the Airflow switch? YES Is there voltage across terminals “5” & “3” on the CR2 Relay? Adjust the Airflow switch or replace if inoperative. YES Replace CR2 Relay. NO NO ** CONTINUED ON NEXT PAGE. YES ** Is there voltage across coils “B” & “A” of the Motor Control Relay? NO Correct wiring between Motor Control Relay and Airflow Switch. Tested with the start switch pressed in. T042D T042D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 37 Will Not Run Gas Manual Timer (Sheet 2 of 2) ** Is there voltage across terminal "7" & "4" of the Motor Control Relay? YES NO Does the Fan Motor Run? NO Replace the Fan Motor. YES Note: Only for non time delay machines Replace Motor Control Relay. Is there voltage across terminals "3" & "5" of the fan motor centrifugal switch with the fan motor running? YES Replace Fan Motor. NO Is there voltage at terminal "5" on the motor control relay to to supply neutral? NO Correct wiring between terminal "5" and supply voltage. Is there voltage to terminal "6" on the motor control relay and supply neutral? NO Correct wiring between terminal "6" and power supply. YES YES Is there voltage across terminal "5" & "8" of the motor control relay? YES Replace motor control relay. Is there voltage across terminal "6" & "9" of the motor control relay? YES Replace motor control relay. NO NO Is there voltage across terminals "1" & "4" of Fan Motor? NO Correct wiring between Fan Motor and contact "8" on the Motor Control Relay. Is there voltage at terminals "1" & "4" of the Cylinder Motor? NO Correct wiring between Cylinder Motor and contact "9" on the Motor Control Relay. YES YES Does the Cylinder Motor Run? NO Replace the Cylinder Motor. YES ** Tested with the start switch pressed in. The Cylinder and Fan Motors are operational. T043D T043D 38 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Run Gas Rotary Coin Drop (Sheet 1 of 2) Single & Stack with and without time delay. Gas units. ** ** Tested with start switch pressed in. ** Is there voltage across terminals "2A" & "1A" of push to start switch? YES Replace Push to Start Switch. Is there voltage across "DOB" contacts (H1-4 and H1-5) on TMR2? YES Replace Time Delay Board. NO NO Note: Reference voltage to transformer neutral. Is there voltage to COM of the Air Flow Switch? NO Correct wiring between COM of Air Flow Switch and "1A" on Start Switch. YES NOTE: The N.O. contact is closed in the rest position due to the physical mounting of the switch. ** Is there voltage across terminals "7" & "8" of CR2 Relay? NO Correct wiring between CR2 Relay and Air Flow Switch. YES ** Is there voltage across terminals "5" & "3" on the CR2 Relay? YES Replace CR2 Relay. ** Is there voltage across "COM" and "N.O." of the air flow switch? YES Adjust the air flow switch or replace if inoperative. NO ** Is there voltage across coils "B" & "A" of the Motor Control Relay? NO NO Correct wiring between Motor Control Relay and Air Flow Switch. YES Is the unit equipped with a Time Delay Board? NO ** Is there voltage across terminal "7" & "4" of the Motor Control Relay? YES YES Replace Motor Control Relay. NO Is there voltage across "H1-6" & "H1-8" on TMR1? NO Correct wiring to TMR1. Is there voltage at terminal "5" on the motor control relay? YES NO Correct wiring between terminal "5" and supply voltage. YES ** Is there voltage across terminals "H1-4" & "H1-8" on TMR2? NO Check for proper operation of Air Flow Switch and check wiring. CONTINUED ON NEXT PAGE. YES ** Tested with the start switch pressed in. T088D T088D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 39 Will Not Run Gas Rotary Coin Drop (Sheet 2 of 2) No Motor Run (run circuit) Is there voltage across terminal "5" & "8" of the motor control relay? YES Replace motor control relay. Is there voltage at terminals "1" & "4" of the Cylinder Motor? NO Correct wiring between Cylinder Motor and contact "9" on the Motor Control Relay. YES NO Is there voltage across terminals "1" & "4" of Fan Motor? NO Correct wiring between Fan Motor and contact "8" on the Motor Control Relay. Does the Cylinder Motor Run? NO Replace the Cylinder Motor. YES YES NO Does the Fan Motor Run? Replace the Fan Motor. The Cylinder and Fan Motors are operational. YES Is there voltage across terminals "3" & "5" of the fan motor centrifugal switch with the fan motor running? YES Replace Fan Motor. NO Is there voltage to terminal "6" on the motor control relay? NO Correct wiring between terminal "6" and power supply. YES Is there voltage across terminal "6" & "9" of the motor control relay? YES Replace motor control relay. NO ** Tested with the start switch pressed in. T089D T089D 40 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Run Steam Manual Timer (Sheet 1 of 2) No motor run (run circuit) Manual Tumblers. Single and stacked units with and without time delay board. Steam heat. NO Is there voltage at terminal “C” on the drying timer? NO Correct wiring between drying timer and lint panel switch. Is the unit equipped with a Time Delay Board? YES YES NOTE: Make sure drying timer is in the "on" position. Is there voltage at terminal “B” on the drying timer? NO Is there voltage across “H1-6” & “H1-8” on TMR1? NO Correct wiring to TMR1. NO Check for proper operation of Airflow Switch. Replace drying timer. YES YES ** Is there voltage across terminals “7” and “8” of CR1 relay? NO Is there voltage across terminals “H1-4” & “H1-8” on TMR2? Correct the wiring between CR1 relay and terminal “B” on drying timer. YES YES ** Is there voltage across terminal “3” and “5” of CR1 relay? YES Is there voltage across “DOB” contacts on TMR2? Replace CR1 relay. YES Replace Time Delay Board. NO NO NOTE: This test to be made with Push to Start Switch pressed in. Is there voltage across terminals “2A” & “1A” of push to Start switch? YES ** Is there voltage across terminals “7” & “8” of CR2 Relay? Replace Push to Start Switch. NO Correct wiring between CR2 Relay and Airflow Switch. NO YES NOTE: The N.O. contact is closed in the rest position due to the physical mounting of the switch. ** Is there voltage across “COM” and “N.O.” of the Airflow switch? YES Is there voltage across terminals “5” & “3” on the CR2 Relay? Adjust the Airflow switch or replace if inoperative. YES Replace CR2 Relay . NO NO CONTINUED ON NEXT PAGE. ** YES ** Is there voltage across “B” & “A” of the Motor Control Relay ? NO Tested with the start switch pressed in. Correct wiring between Motor Control Relay and Airflow Switch. T017D T017D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 41 Will Not Run Steam Manual Timer (Sheet 2 of 2) ** Is there voltage across terminal "7" & "4" of the Motor Control Relay? YES NO Does the Fan Motor Run? Replace the Fan Motor. YES NO Note: only for non time delay machines Replace Motor Control Relay. Is there voltage across terminals "3" & "5" of the fan motor centrifugal switch with the fan motor running? YES Replace Fan Motor. NO Is there voltage at terminal "5" on the motor control relay to to supply neutral? NO Correct wiring between terminal "5" and supply voltage. Is there voltage to terminal "6" on the motor control relay and supply neutral? NO Correct wiring between terminal "6" and power supply. YES YES Is there voltage across terminal "5" & "8" of the motor control relay? YES Replace motor control relay. Is there voltage across terminal "6" & "9" of the motor control relay? YES Replace motor control relay. NO NO Is there voltage across terminals "1" & "4" of Fan Motor? NO Correct wiring between Fan Motor and contact "8" on the Motor Control Relay. Is there voltage at terminals "1" & "4" of the Cylinder Motor? NO Correct wiring between Cylinder Motor and contact "9" on the Motor Control Relay. YES YES Does the Cylinder Motor Run? NO Replace the Cylinder Motor. YES ** Tested with the start switch pressed in. The Cylinder and Fan Motors are operational. T018D T018D 42 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Run Steam Rotary Coin Drop (Sheet 1 of 2) Single & Stack with and without time delay. Steam units. ** ** Tested with start switch pressed in and vend satisfied. ** Is there voltage across terminals "2A" & "1A" of push to start switch? YES Is there voltage across "DOB" contacts on TMR2? YES Replace Time Delay Board. Replace Push to Start Switch. NO NO Note: Reference voltage to transformer neutral. Is there voltage to COM of the Air Flow Switch? NO Correct wiring between COM of Air Flow Switch and "1A" on Start Switch. ** Is there voltage across terminals "7" & "8" of CR2 Relay? NO Correct wiring between CR2 Relay and Air Flow Switch. YES YES NOTE: The N.O. contact is closed in the rest position due to the physical mounting of the switch. ** Is there voltage across "COM" and "N.O." of the air flow switch? YES Adjust the air flow switch or replace if inoperative. ** Is there voltage across terminals "5" & "3" on the CR2 Relay? YES NO ** Is there voltage across "B" & "A" of the Motor Control Relay? NO Replace CR2 Relay. NO Correct wiring between Motor Control Relay and Air Flow Switch. YES Is the unit equipped with a Time Delay Board? NO ** Is there voltage across terminal "7" & "4" of the Motor Control Relay? YES YES Replace Motor Control Relay. NO Is there voltage across "H1-6" & "H1-8" on TMR1? NO Correct wiring to TMR1. Is there voltage at terminal "5" on the motor control relay? YES ** NO Correct wiring between terminal "5" and supply voltage. YES Is there voltage across terminals "H1-4" & "H1-8" on TMR2? NO Check for proper operation of Air Flow Switch and check wiring. CONTINUED ON NEXT PAGE. YES ** Tested with the start switch pressed in. T064D T064D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 43 Will Not Run Steam Rotary Coin Drop (Sheet 2 of 2) No Motor Run (run circuit) Is there voltage across terminal "5" & "8" of the motor control relay? YES Replace motor control relay. Is there voltage at terminals "1" & "4" of the Cylinder Motor? NO Correct wiring between Cylinder Motor and contact "9" on the Motor Control Relay. YES NO Is there voltage across terminals "1" & "4" of Fan Motor? NO Correct wiring between Fan Motor and contact "8" on the Motor Control Relay. Does the Cylinder Motor Run? NO Replace the Cylinder Motor. YES YES NO Does the Fan Motor Run? Replace the Fan Motor. The Cylinder and Fan Motors are operational. YES Only for units without time delay boards. Is there voltage across terminals "3" & "5" of the fan motor centrifugal switch with the fan motor running? YES Replace Fan Motor. NO Is there voltage to terminal "6" on the motor control relay? NO Correct wiring between terminal "6" and power supply. YES Is there voltage across terminal "6" & "9" of the motor control relay? YES Replace motor control relay. NO ** Tested with the start switch pressed in. T065D T065D 44 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Electric Manual Timer (Sheet 1 of 2) With and without Time Delay Board, Single and Stacked units, Single and 3 Phase power supply. NOTE: The following tests are conducted with the Heat Timer in the "ON" position with the machine running and calling for heat. Voltage checks are referenced to transformer neutral. Is there voltage across terminals "1" & "6" of the Temp Control Bd? Is there voltage at Air Flow Switch (AFS) "N.C." terminal to transformer neutral? NO Replace inoperative switch or correct air flow vane operation. NO Correct wiring between A.F.S. and terminal "6" on CR1. YES YES YES NO Is there voltage at terminal "6" on CR1 to transformer neutral? Is there voltage across terminals "5" & "6" of the Temp Control Bd? YES NO Is the thermistor shorted or open? YES Is there voltage from terminal "4" on CR1 to transformer neutral? Replace thermistor. NO Replace CR1. YES NO YES Is temperature selection switch shorted or open? YES Is unit equipped with time delay board? Replace selection switch. NO NO Replace the Temperature Control Board. Is there voltage to terminal "3" of fan motor? NO Correct wiring between fan motor terminal "3" and CR1 terminal "4". Is there voltage from terminal "6" on CR2 to transformer neutral? NO Correct wiring between terminal "6" on CR2 to terminal "4" on CR1. YES YES CONTINUED ON NEXT PAGE Is there voltage from terminal "4" on CR2 to transformer neutral? Is there voltage at terminal 3 & 5 of fan motor? NO NO Replace CR2. Replace fan motor. YES YES Correct wiring between motor terminal "5" and Temp Control Board terminal "1". Correct wiring between CR2 terminal "4" & terminal "1" on Temp Control Board. T054D T054D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 45 Will Not Heat Electric Manual Timer (Sheet 2 of 2) NO HEAT CONTINUED Note: Voltage checks are referenced to transformer neutral. Is there voltage to the input side of the Cabinet Limit? NO Correct wiring between Cabinet Limit and Temp Control Board. YES Is there voltage to the output side of the Cabinet Limit? Do the elements produce heat? NO Replace elements. YES NO Replace the Cabinet Limit. NO Correct wiring between Stove limit and Cabinet Limit. NO Replace the Stove Limit. UNIT OPERATIONAL YES Is there voltage to the input side of the Stove Limit? YES Is there voltage to the output side of the Stove Limit? YES Is there voltage across "HC1" & "HC2" element contactor coils? NO Correct wiring between element contactor coils and stove limit. YES Is there votlage across the elements? NO Check wiring between elements, contactors and supply. Correct if necessary. YES T055D T055D 46 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Electric Rotary Coin Drop (Sheet 1 of 2) Single and stacked units with single and three phase supply. Note: Tests are conducted with unit running and calling for heat. All voltage checks are referenced to transformer neutral. Is there voltage on "FS-2" of EDC control? NO Correct wiring between "FS-2" and COM of lint drawer. YES NO Correct wiring between terminal "3" of fan motor centrifugal switch and terminal "4" of motor control relay. YES Replace EDC control. Replace thermistor. NO Is there voltage on "FS-1" of EDC control? Is there voltage on terminal "3" of fan motor centrifugal switch? Is there voltage at terminal "5" of fan motor centrifugal switch? NO Is the thermistor operational? YES Is there voltage on COM of air flow switch? NO Correct wiring between COM of air flow switch and "FS-1" of EDC control. NO Check for proper function of air flow switch and replace if necessary. Is there voltage to the input side of the cabinet limit? NO Correct wiring between cabinet limit and terminal "5" of fan motor centrifugal switch. Is there voltage at the output of the cabinet limit? NO Replace cabinet limit. YES NO Correct wiring between terminal 7 on motor control relay and N.C. terminal on air flow switch. YES Is there voltage at terminal"4" of motor control relay? YES YES YES Is there voltage on terminal "7" of motor control relay? Replace fan motor. YES YES Is there voltage at "N.C." terminal of air flow switch? NO Is there voltage to the input side of the stove limit? NO Correct wiring between stove limit and cabinet limit. YES NO Replace motor control relay. Continued on next page. YES T034D T034D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 47 Will Not Heat Electric Rotary Coin Drop (Sheet 2 of 2) EDC No Heat continued. Is there voltage to the output side of the stove limit? NO Replace the stove limit. YES Is there voltage across coils "HC1" & "HC2"? NO Correct wiring to the coils of "HC1" and "HC2". YES Is there voltage across the heating elements? NO Correct wiring between elements and supply. Replace "HC1" and or "HC2" if necessary YES Do the elements produce heat? NO Replace elements. YES Unit operational. T035D T035D 48 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Electric Rotary Coin Drop (with and without time delay board) (Sheet 1 of 2) Single & Stacked Tumblers with and without time delay. Single and Three phase uiits. Is there voltage across across terminals "1" & "6" of the Temp Control Board? Is there voltage at Air Flow Switch "N.C." terminal to transformer neutral? NO Is there voltage across terminals "5" & "6" of the Temp Control Bd? Is there voltage at COM on Switch "B" to transformer neutral? NO Correct wiring between air flow switch and COM on Switch "B". YES NO Is the thermistor shorted or open? Adjust the Air Flow Switch or replace if inoperative. YES YES YES NO YES Replace thermistor. Is there voltage from "N.C." on Switch "B" to transformer neutral? NO Replace Switch "B". NO YES Is temperature selection switch shorted or open? YES Replace selection switch. YES NO Replace the Temperature Control Board. Is there voltage on terminal "3" of fan motor to transformer neutral? Is the unit equipped with a Time Delay Board? NO NO Correct wiring between terminal "3" of fan motor and N.C. terminal on Switch "B". Is there voltage from terminal "6" on CR2 to transformer neutral? NO Correct wiring between terminal "6" on CR2 to terminal "N.C." on Switch "B". YES YES With fan motor running is there voltage from terminal "5" to transformer neutral? NO Replace Fan Motor. YES Is there voltage on terminal "1" of Temp Board to transformer neutral? YES CONTINUED ON NEXT PAGE Is there voltage from terminal "4" on CR2 to transformer neutral? NO Replace CR2. YES NO Correct wiring between terminal "1" of Temp Board to terminal "5" of fan motor. Correct wiring between terminal "4" on CR2 & terminal "1" on Temp Control Board. Power supply to Temp Control Board is good. T077D T077D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 49 Will Not Heat Electric Rotary Coin Drop (with and without time delay board) (Sheet 2 of 2) NO HEAT CONTINUED Note: Voltage checks are referenced to transformer neutral. Is there voltage to the input side of the Cabinet Limit? NO Correct wiring between Cabinet Limit and Temp Control Board. NO Replace elements. YES YES Is there voltage to the output side of the Cabinet Limit? Do the elements produce heat? NO Replace the Cabinet Limit. NO Correct wiring between Stove limit and Cabinet Limit. NO Replace the Stove Limit. NO Correct the wiring to the coils. UNIT OPERATIONAL YES Is there voltage to the input side of the Stove Limit? YES Is there voltage to the output side of the Stove Limit? YES Is there voltage across the coils of "HC1" & "HC2"? YES Is there voltage across the elements? NO Check the wiring between elements, contactors and supply. Correct if necessary. YES T078D T078D 50 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Electric/Gas OPL Microprocessor (Sheet 1 of 3) Note: Testing conducted with unit running and calling for heat. Single and three phase supply. Reference voltage to transformer neutral terminal "3". Is there votlage at YES Continued on next terminal "5" on OPL page column 2. Micro? NO Test conducted with unit running and calling for heat. Is the thermister operating properly? NO Replace thermister. Is there voltage across terminals "2" & "3" of transformer secondary? NO Replace transformer. YES Note: Reference voltage to transformer secondary neutral terminal "3". Is there voltage to input of secondary fuse? NO Correct wiring between secondary fuse and transformer. YES YES Reference voltage to supply neutral. Is power supplied to unit? NO Connect supply and run unit. YES NO Replace secondary fuse. YES Is there voltage to input of primary fuse(s)? NO Correct wiring between primary fuse and supply. YES Is there voltage to "N.O." terminal of door switch? NO Correct wiring between "N.O." terminal of door switch and secondary fuse. YES Is there voltage to output of primary fuse(s)? NO Change primary fuse. YES With door closed is there voltage to "COM" of door switch? NO Check for proper operation, replace door switch if necessary. YES Is there voltage across terminals "1" & "2" on primary of transformer? YES Is there voltage to output of secondary fuse? NO Correct wiring between transformer and primary fuse. Is there voltage to "N.O." of lint panel switch? NO Correct wiring between "N.O." of lint panel switch and "COM" of door switch. YES Continued on next page column 1. T010D T010D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 51 Will Not Heat Electric/Gas OPL Microprocessor (Sheet 2 of 3) NO HEAT Column 1 Column 2 Is there voltage to "COM" of lint panel switch with lint panel closed? NO Check for proper operation and replace lint panel switch if necessary. The following tests are conducted with the unit running and calling for heat. Is there voltage at "COM" of air flow switch? YES NO Correct wiring between "COM" & OPL Micro. YES Is there voltage at terminal "8" of OPL Micro? NO Correct wiring between terminal "8" of OPL Micro and "COM" of lint panel switch. Is there voltage at "N.C." terminal of air flow switch? YES NO Check for proper operation and replace if necessary. YES Is there voltage to terminal "13" of OPL Micro? NO Three phase Replace OPL Micro. YES Is the unit supplied with single phase or three phase power? single phase Is there voltage at terminal "6" of OPL Micro? NO Correct wiring between terminal "6" & "13" on OPL Micro. Is there voltage at terminal "7" of motor control relay for "OM" models or terminal "8" for "RM" models? NO YES Correct wiring between terminal "7/8" of motor control relay and "N.C." of air flow switch. YES Replace OPL Micro. Is there voltage at terminal "4" of motor control relay for "OM" models or terminal "6" for "RM" models? Is there voltage to terminal 14 on motor control relay? NO YES Correct wiring between terminal "14" on motor control relay and N.C. terminal of air flow switch. NO Replace motor control relay. YES Is there voltage at terminal "3" of fan motor centrifugal switch? NO Correct wiring between fan motor centrifugal switch and motor control relay. YES Is there votlage across terminals 14 & 13 of motor control relay? NO Is there voltage at terminal "5" of fan motor centrifugal switch? NO Replace fan motor. YES YES Replace motor control relay. Continued on next page. T011D T011D 52 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Electric/Gas OPL Microprocessor (Sheet 3 of 3) Continued from column 2 of previous page. Is there voltage to the input of the cabinet limit? NO Is there voltage to terminal "1" of ICM board? Correct wiring between cabinet limit and terminal "5" of fan motor centrifugal switch. NO Replace ICM board. YES YES Is there voltage across the coils of the gas valve? Is there voltage to output of cabinet limit? NO NO Correct wiring to gas valve coils. NO Replace the coils or complete gas valve. Replace cabinet limit. YES YES Is there gas flow through the valve? Is there voltage to input of stove limit? NO Correct wiring between stove limit and cabinet limit. YES Is there a flame? YES YES Unit is operational. NO Is there voltage to the output side of the stove limit? NO Replace stove limit. Does the ignitor spark? YES Check gas pressures and adjust if necessary. YES NO Is the unit equipped with gas heat or electric heat? Replace igniter or ignition cable. ELECTRIC GAS Is there voltage across HC1 & HC2 coils? Is there voltage to terminal "2" of ICM board? NO Correct wiring between ICM board and stove limit. NO Correct the wiring to the HC1 and/or HC2 coils. YES Do the elements produce heat? YES UNIT OPERATIONAL. NO Correct wiring between supply, contacts and elements. Replace contactors and/or elements if necessary. YES T012D T012D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53 Will Not Heat Gas EDC Models (Sheet 1 of 2) Single and stacked gas units. Note: Tests are conducted with unit running and calling for heat. All voltage checks are referenced to transformer neutral. Is there voltage on "FS-2" of EDC control? NO Correct wiring between "FS-2" and COM of lint drawer. YES NO Correct wiring between terminal "3" of fan motor centrifugal switch and terminal "4" of motor control relay. YES Replace EDC control. Replace thermistor. Is there voltage on "FS-1" of EDC control? Is there voltage on terminal "3" of fan motor centrifugal switch? Is there voltage across terminals "3" & "5" of fan motor centrifugal switch? NO NO Is the thermistor operational? YES Is there voltage on COM of air flow switch? NO Replace fan motor. YES Correct wiring between COM of air flow switch and "FS-1" of EDC control. NO Is there voltage to the input side of the cabinet limit? NO Correct wiring between cabinet limit and terminal "5" of fan motor centrifugal switch. YES YES Is there voltage across COM & "N.C." terminal of air flow switch? YES YES Check for proper function of air flow switch and replace if necessary. Is there voltage across cabinet limit? YES Replace cabinet limit. NO Correct wiring between stove limit and cabinet limit. NO NO Is there voltage on terminal "7" of motor control relay? NO Correct wiring between terminal "7" on motor control relay and N.C. terminal on air flow switch. YES Is there voltage across terminals "7" & "4" of motor control relay? Is there voltage to the input side of the stove limit? YES YES Replace motor control relay. Continued on next page. NO T032D T032D 54 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Gas EDC Models (Sheet 2 of 2) EDC No Heat continued. Is there voltage to the output side of the stove limit? NO Replace the stove limit. Is there a flame? YES Unit operational. NO YES Is there voltage to terminal "2" of the ICM board? NO Correct wiring between terminal "2" of ICM board and stove limit. YES Is there voltage at terminal "1" of ICM board? NO Replace ICM board. YES Is there voltage across the coils of the gas valve? NO Correct wiring between gas valve and ICM board. NO Replace gas valve coils or complete gas valve. NO Replace high voltage ignition cable or igniter. YES Is there gas flow through the gas valve? YES Does the igniter spark? YES T033D T033D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 55 Will Not Heat Gas Manual Timer (Sheet 1 of 2) NOTE: The following tests are conducted with the Heat Timer in the "ON" position with the machine running and calling for heat. Voltage checks are referenced to transformer neutral. Is there voltage across terminals "1" & "6" of the Temp Control Bd? Single and stacked units with and without time delayboards. Is there voltage at Air Flow Switch (AFS) "N.C." terminal to transformer neutral? NO Replace inoperative switch or correct air flow vane operation. YES YES YES NO Is there voltage at terminal "6" on CR1 to transformer neutral? Is there voltage across terminals "5" & "6" of the Temp Control Bd? NO Correct wiring between A.F.S. and terminal "6" on CR1. YES NO Is there voltage from terminal "4" on CR1 to transformer neutral? Is the thermistor shorted or open? YES Replace thermistor. NO YES NO Replace selection switch. NO Is there voltage to terminal 3 of fan motor? NO Correct wiring between fan motor terminal 3 and CR1 terminal 4. Is there voltage across terminal 3 & 5 of fan motor? YES NO Correct wiring between terminal "6" on CR2 to terminal "4" on CR1. YES Is there voltage from terminal "4" on CR2 to transformer neutral? YES CONTINUED ON NEXT PAGE Is unit equipped with time delay board? Is there voltage from terminal "6" on CR2 to transformer neutral? Replace the Temperature Control Board. Replace CR1. YES YES Is the temperature selection switch shorted or open? NO NO Replace CR2. YES Replace fan motor. Correct wiring between CR2 terminal "4" & terminal "1" on Temp Control Board. NO Correct wiring between motor terminal 5 and Temp Control Board terminal 1. T044D T044D 56 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Gas Manual Timer (Sheet 2 of 2) NO HEAT CONTINUED Note: Voltage checks are referenced to transformer neutral. Is there voltage to the input side of the Cabinet Limit? NO Correct wiring between Cabinet Limit and Temp Control Board. Is there voltage across the coils of the gas valve? NO Replace the Cabinet Limit. Is there gas flow through the gas valve? NO Correct wiring between Stove limit and Cabinet Limit. Does the igniter spark? YES Is there voltage to the output side of the Stove Limit? NO Replace gas valve or gas valve coils. NO Replace high voltage cable or igniter. YES YES Is there voltage to the input side of the Stove Limit? Correct wiring between gas valve and ICM board. YES YES Is there voltage to the output side of the Cabinet Limit? NO YES NO Replace the Stove Limit. YES NO Is there a flame? YES UNIT OPERATIONAL Is there voltage across terminals "2" & "3" of ICM board? NO Correct wiring betwee ICM board and Stove limit. YES Is there voltage across terminals "1" & "3" of the ICM board? NO Replace ICM board YES T045D T045D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 57 Will Not Heat Gas Rotary Coin Drop (Sheet 1 of 2) Single & Stacked Tumblers with and without time delay. Is there voltage across terminals "1" & "6" of the Temp Control Bd? Is there voltage at Air Flow Switch "N.C." terminal to transformer neutral? NO Is there voltage across terminals "5" & "6" of the Temp Control Bd? Is there voltage at COM on Switch "B" to transformer neutral? NO Correct wiring between air flow switch and COM on Switch "B". YES NO Is the thermistor shorted or open? Replace inoperative switch or correct air flow vane operation. YES YES YES NO YES Replace thermistor. Is there voltage from "N.C." on Switch "B" to transformer neutral? NO Replace Switch "B". NO YES Is temperature selection switch shorted or open? YES Replace selection switch. YES NO Replace the Temperature Control Board. Is there voltage on terminal "3" of fan motor to transformer neutral? Is the unit equipped with a Time Delay Board? NO NO Correct wiring between terminal "3" of fan motor and "N.C." terminal on switch "B". Is there voltage from terminal "6" on CR2 to transformer neutral? NO Correct wiring between terminal "6" on CR2 to terminal "N.C." on Switch "B". YES YES With fan motor running is there voltage from terminal "5" to transformer neutral? NO Replace Fan Motor. YES Is there voltage on terminal "1" of Temp Board to transformer neutral? YES CONTINUED ON NEXT PAGE Is there voltage from terminal "4" on CR2 to transformer neutral? NO Replace CR2. YES NO Correct wiring between terminal "1" of Temp Board to terminal "5" of fan motor. Correct wiring between terminal "4" on CR2 & terminal "1" on Temp Control Board. Power supply to Temp Control Board is good. T090D T090D 58 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Gas Rotary Coin Drop (Sheet 2 of 2) NO HEAT CONTINUED Note: Voltage checks are referenced to transformer neutral. Is there voltage to the input side of the Cabinet Limit? NO Correct wiring between Cabinet Limit and Temp Control Board. Is there voltage across the coils of the gas valve? YES Is there voltage to the output side of the Cabinet Limit? NO Replace the Cabinet Limit. Is there gas flow through the gas valve? NO Correct wiring between Stove limit and Cabinet Limit. Replace gas valve coils or complete gas valve. Does the igniter spark? NO Replace high voltage ignition cable or igniter. YES NO Replace the Stove Limit. NO Is there a flame? YES YES Is there voltage across terminals "2" & "3" of the ICM Board? NO YES YES Is there voltage to the output side of the Stove Limit? Correct wiring between gas valve and ICM Board. YES YES Is there voltage to the input side of the Stove Limit? NO NO Correct wiring between ICM board and Stove Limit or neutral. UNIT OPERATIONAL YES Is there voltage across terminals "1" & "3" of the ICM Board? NO Replace the ICM Board. YES T091D T091D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 59 Will Not Heat Steam EDC Models (Sheet 1 of 2) Single and Stacked units. Note: Tests are conducted with unit running and calling for heat. All voltage checks are referenced to transformer neutral. Is there voltage on “FS-2” of EDC control? Correct wiring between “FS-2” and COM of lint drawer. NO NO Correct wiring between terminal “3” of fan motor centrifugal switch and terminal “4” of motor control relay. YES YES Replace EDC control. Replace thermistor. Is there voltage on “FS-1” of EDC control? Is there voltage on terminal “3” of fan motor centrifugal switch? NO NO Is there voltage across terminals “3” & “5” of fan motor centrifugal switch? Is the thermistor operational? YES Is there voltage on COM of Airflow switch? NO YES Replace fan motor. YES NO Correct wiring between COM of Airflow switch and “FS-1” of EDC control. Is there voltage to the input side of the cabinet limit? NO Correct wiring between cabinet limit and terminal “5” of fan motor centrifugal switch. YES YES Is there voltage across COM & “N.C.” terminal of Airflow switch? YES Check for proper function of Airflow switch and replace if necessary. Is there voltage across cabinet limit? YES Replace cabinet limit. NO Correct wiring between stove limit and cabinet limit. NO NO Is there voltage on terminal “7” of motor control relay? NO Correct wiring between terminal 7 on motor control relay and N.C. terminal on Airflow switch. Is there voltage to the input side of the stove limit? YES YES Is there voltage across terminals “7” & “4” of motor control relay? YES Replace motor control relay. Continued on next page. NO T096D T096D 60 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Steam EDC Models (Sheet 2 of 2) Is there voltage to the output side of the stove limit? NO Replace the stove limit. NO Correct wiring to steam valve coil. NO Repair or replace steam valve. NO Check for proper steam supply. Correct if necessary. YES Is there voltage across steam valve coil? YES Does steam valve operate properly? YES Is heat produced? YES Unit operational. T097D T097D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 61 Will Not Heat Steam Manual Timer (Sheet 1 of 2) Single and stacked units with and without time delayboards, manual timers. NOTE: The following tests are conducted with the Heat Timer in the "ON" position with the machine running and calling for heat. Voltage checks are referenced to transformer neutral. Is there voltage across terminals "1" & "6" of the Temp Control Bd? Is there voltage at Air Flow Switch "N.C." terminal to transformer neutral? NO YES YES NO Adjust the Air Flow Switch or replace if inoperative. NO Correct wiring between A.F.S. and terminal "6" on CR1. YES Is there voltage at terminal "6" on CR1 to transformer neutral? Is there voltage across terminals "5" & "6" of the Temp Control Bd? YES NO Is there voltage from terminal "4" on CR1 to transformer neutral? Is the thermistor shorted or open? YES YES YES YES NO Replace selection switch. NO Is there voltage to terminal "3" of fan motor? NO Correct wiring between fan motor terminal "3" and CR1 terminal "4". Is there voltage across terminal "3" & "5" of fan motor? NO Correct wiring between terminal "6" on CR2 to terminal "4" on CR1. YES Is there voltage from terminal "4" on CR2 to transformer neutral? YES CONTINUED ON NEXT PAGE Is unit equipped with time delay board? Is there voltage from terminal "6" on CR2 to transformer neutral? Replace the Temperature Control Board. Replace CR1. Replace thermistor. NO Is temperature selection switch shorted or open? NO NO Replace CR2. YES YES Replace fan motor. Correct wiring between CR2 terminal "4" & terminal "1" on Temp Control Board. NO Correct wiring between motor terminal "5" and Temp Control Board terminal "1". T019D T019D 62 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Steam Manual Timer (Sheet 2 of 2) NO HEAT CONTINUED Note: Voltage checks are referenced to transformer neutral. Is there voltage to the input side of the Cabinet Limit? NO Correct wiring between Cabinet Limit and Temp Control Board. YES Is heat produced? NO Check for proper steam supply. Correct if necessary. YES UNIT OPERATIONAL Is there voltage to the output side of the Cabinet Limit? NO Replace the Cabinet Limit. NO Correct wiring between Stove limit and Cabinet Limit. NO Replace the Stove Limit. NO Correct wiring to the steam valve. NO Replace steam valve. YES Is there voltage to the input side of the Stove Limit? YES Is there voltage to the output side of the Stove Limit? YES Is there voltage across the coil of the steam valve? YES Do the steam valves operate properly? YES T020D T020D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 63 Will Not Heat Steam OPL Microprocessor (Sheet 1 of 3) Testing conducted with unit running and calling for heat. Reference voltage to transformer neutral terminal "3". Is there votlage at terminal "5" on OPL Micro? YES Continued on next page column 2. Is there voltage across terminals "2" & "3" of transformer secondary? NO Replace transformer. YES NO Note: Reference voltage to transformer secondary neutral terminal "3". Is the thermister operating properly? NO Replace thermister. Is there voltage to input of secondary fuse? NO Correct wiring between secondary fuse and transformer. YES YES Reference voltage to supply neutral. Is power supplied to unit? NO Connect supply and run unit. NO Replace secondary fuse. YES YES Is there voltage to input of primary fuse(s)? NO Correct wiring between primary fuse and supply. Is there voltage to "N.O" terminal of door switch? NO Correct wiring between "N.O." terminal of door switch and secondary fuse. YES YES Is there voltage to output of primary fuse(s)? NO Change primary fuse. With door closed is there voltage to "COM" of door switch? NO Check for proper operation, replace door switch if necessary. YES YES Is there voltage across terminals "1" & "2" on primary of transformer? YES Is there voltage to output of secondary fuse? NO Correct wiring between transformer and primary fuse. Is there voltage to "N.O." of lint panel switch? NO Correct wiring between "N.O." of lint panel switch and "COM" of door switch. YES Continued on next page column 1. T003D T003D 64 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Steam OPL Microprocessor (Sheet 2 of 3) NO HEAT Column 1 Column 2 Is there voltage to "COM" of lint panel switch with lint panel closed? NO Check for proper operation and replace lint panel switch if necessary. The following tests are conducted with the unit running and calling for heat. Is there voltage at "COM" of air flow switch? YES NO Correct wiring between "COM" & OPL Micro. NO Check for proper oprerationand replace if necessary. YES Is there voltage at terminal "8" of OPL Micro? NO Correct wiring between terminal "8" of OPL Micro and "COM" of lint panel switch. Is there voltage at "N.C." terminal of air flow switch? YES YES Is there voltage to terminal "13" of OPL Micro? NO Three phase Replace OPL Micro. YES Is the unit supplied with single phase or three phase power? Single phase Is there voltage at terminal "6" of OPL Micro? NO Correct wiring between terminal "6" & "13" on OPL Micro. Is there voltage at terminal "7" of motor control relay ? NO Correct wiring between terminal "7" of motor control relay and "N.C." of air flow switch. YES YES Replace OPL Micro. Is there voltage at terminal "4" of motor control relay? Is there voltage to terminal 14 on motor control relay? NO YES Correct wiring between terminal 14 on motor control relay and N.C. terminal of air flow switch. NO Replace motor control relay. YES Is there voltage at terminal "3" of fan motor centrifugal switch? NO Correct wiring between fan motor centrifugal switch and motor control relay. YES Is there votlage to terminal 13 of motor control relay? YES Is there voltage at terminal "5" of fan motor centrifugal switch? NO Replace fan motor. NO YES Replace motor control relay. Continued on next page. T004D T004D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 65 Will Not Heat Steam OPL Microprocessor (Sheet 3 of 3) Continued from column 2 of previous page. Is there voltage to the input of the cabinet limit? NO Correct wiring between cabinet limit and terminal "5" of fan motor centrifugal switch. YES Is heat produced? NO Check for proper steam supply. Correct if necessary. YES UNIT OPERATIONAL. Is there voltage to output of cabinet limit? NO Replace cabinet limit. YES Is there voltage to input of stove limit? NO Correct wiring between stove limit and cabinet limit. YES Is there voltage to the output side of the stove limit? NO Replace stove limit. YES Is there voltage across steam valve coil? NO Correct wiring to steam valve coil. NO Replace steam valve. YES Does the steam valve operate properly? YES T005D T005D 66 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201 Will Not Heat Steam Rotary Coin Drop (Sheet 1 of 2) Single & Stacked Tumblers with and without time delay. Is there voltage across terminals "1" & "6" of the Temp Control Board? Is there voltage at Air Flow Switch "N.C." terminal to transformer neutral? NO Is there voltage across terminals "5" & "6" of the Temp Control Board? Is there voltage at COM on Switch "B" to transformer neutral? NO Correct wiring between A.F.S. and COM on Switch "B". YES NO Is the thermistor shorted or open? Adjust the Air Flow Switch or replace if inoperative. YES YES YES NO YES Replace thermistor. Is there voltage from "N.C." on Switch "B" to transformer neutral? NO Replace Switch "B". NO YES Is temerature selection switch shorted or open? YES Replace selection switch. YES NO Replace the Temperature Control Board. Is there voltage on terminal "3" of fan motor to transformer neutral? Is the unit equipped with a Time Delay Board? NO NO Correct wiring between terminal "3" of fan motor and N.C. terminal on switch B. Is there voltage from terminal "6" on CR2 to transformer neutral? NO Correct wiring between terminal "6" on CR2 to terminal "N.C." on Switch "B". YES YES With fan motor running is there voltage from terminal "5" to transformer neutral? NO Replace Fan Motor. YES Is there voltage on terminal "1"of Temp Board to transformer neutral? YES CONTINUED ON NEXT PAGE Is there voltage from terminal "4" on CR2 to transformer neutral? NO Replace CR2. YES NO Correct wiring between terminal "1" of Temp Board to terminal "5" of fan motor. Correct wiring between terminal "4" on CR2 & terminal "1" on Temp Control Board. Power supply to Temp Control Board is good. T066D T066D 70172201 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 67 Will Not Heat Steam Rotary Coin Drop (Sheet 2 of 2) NO HEAT CONTINUED Note: Voltage checks are referenced to transformer neutral. Is there voltage to the input side of the Cabinet Limit? NO Correct wiring between Cabinet Limit and Temp Control Board. NO Check for proper steam supply. Correct if necessary. YES YES Is there voltage to the output side of the Cabinet Limit? Is heat produced? NO Replace the Cabinet Limit. NO Correct wiring between Stove limit and Cabinet Limit. NO Replace the Stove Limit. NO Correct wiring to steam valve NO Replace steam valve. UNIT OPERATIONAL YES Is there voltage to the input side of the Stove Limit? YES Is there voltage to the output side of the Stove Limit? YES Is there voltage across coil of steam valve? YES Does the steam valve operate properly? YES T067D T067D 68 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70172201