Download Digital Security Controls PC1575 Specifications

Transcript
Distributed By:
North America
Security
Products
Catalogue
The Art
Of Security
Digital Security Controls Ltd.
3301 Langstaff Road
Concord, Ontario
Canada L4K 4L2
Tel (905) 760-3000
Fax (905) 760-3030
Toll Free (888) 888-7838
www.dscgrp.com
An ISO 9001 Registered Company
Part# 29002784 R002
Printed in Canada 02/00
™
Systems
Classic™
The DSC Group of Companies is recognized as a leading manufacturer of intrusion alarm systems and detection devices worldwide.
DSC has a full range of security products including intrusion alarms, alarm communications, fire alarms, home automation, video
surveillance/transmission, access control, and long range radio. The DSC Group brings a singular dedication to the full spectrum of
commercial and residential security needs. This dedication is expressed through the establishment of worldwide leadership in
technology, manufacturing, and distribution. We are able to build upon this foundation with our size, expertise support, innovation,
and unique vision.
TM
®
Already recognized for product excellence by listing agencies, security dealers, distributors and millions of satisfied consumers, the
DSC Group of Companies has the added recognition of ISO 9001 certification for its main engineering and manufacturing facility. The
ISO 9001 rating represents an internationally recognized benchmark to assure our customers of true product quality and is a key
part of DSC's commitment to market its products worldwide.
Digital Security Controls Ltd. stands as the premier manufacturer of
INTRUSION ALARM SYSTEMS and DETECTION DEVICES. Behind that
success is an unwavering commitment to continually bring new
standards of performance, reliability and value to the professional
security installer. At the forefront of wireless technology, integrated
systems and false alarm prevention, Digital Security Controls Ltd.
personifies “The Art of Security”.
®
MAXSYS
™
Sensors
Wireless
Addressable
4 to 32 zone hybrid (wireless/hardwired) security systems
2
Traditional fixed size, hardwired security systems from 4 to 16 zones
4
8 to 32 zone hybrid (wireless/hardwired) life safety and security system,
offering automation control, integrated audio, and telephone
6
8 to 64 and 16 to 128 zone modular security system offering
a network configuration, hybrid (hardwired/wireless) and much more
8
Standalone 10 zone 900MHz spread spectrum security system with a full
range of wireless detectors.
12
900MHz Spread Spectrum wireless controls & detectors
13
Addressable detectors
14
Standard, long range and quad PIR detectors
15
TM
Internationally recognized as the manufacturer of choice for DIGITAL
RECEIVERS, SG Security Communications is now introducing a new
commitment to serve a wider range of communication needs across the
security industry. From digital to video transmission, from telco to radio
telemetry, SG Security Communications is redefining security
communications.
TM
o
TM
A ceiling-mounted 360 dual technology PIR and glassbreak detector
16
A new generation of dual element PIR detectors offering
advanced pet immunity and superior performance
17
Dual technology PIR/Microwave detectors
18
Advanced digital glassbreak detectors and glassbreak simulator
19
2-wire and 4-wire photoelectric smoke detectors and alarms
20
Digital key telephone system with integrated security features
22
Cellular alarm transmitter
24
Skyroute Wireless Communications
24
Sur-Gard digital receivers with up to 14 line expansion with 3584
event memory capability and options for 2 way listen-in and video
25
®
Arguably the most respected and rapidly growing manufacturer serving
the ACCESS CONTROL MARKET, Kantech's reputation is built upon their
success in delivering more features, more innovation, and - ultimately much higher product value to a wide range of access control users.
™
™
Telephone System
As the wireless alarm signal transmission experts, SG Wireless
Communications provides “state of the art” intelligent radio networks and
services that allow the alarm professional to make wireless technology
accessible to all of their customers. SG wireless communications networks,
related equipment and services are manufactured to be fully compatible
with DSC control panels.
As the leader in innovative CCTV Products, Deltavision designs and
manufactures high performance CCTV equipment that is a direct reflection
of their continual pursuit of total quality, innovation and value.
Recognized as a leading manufacturer of fire and security equipment,
Bentel Security boasts national and international approval and quality
marks that guarantee both the functionality and the high quality of their
products, making Bentel a valuable addition to the DSC Group of
Companies.
™
Alarm Communications
™
™
Downlook automated still frame video transmission system
26
CCTV cameras and monitors
27
®
®
•1•
Classic
PC580/1555
4 -32 Zone Hybrid Wireless Security Systems
™
Remote Service
The offsite upload and download service
capabilities of the PC580 and PC1555 mean
that, should an equipment problem ever occur,
it can frequently be identified and diagnosed
over the phone - often eliminating the need for
a service call altogether.
Hybrid Wireless Expansion
Complete life safety
PC1555
4 - 32 Zone Control Panel
6 - 32 Zone Control Panel
• Up to 32 zones using any combination of zones
available from:
- 4 hardwired zones on control panel
- 8 keypad zone inputs (1 per keypad)
- 32 wireless zones (with PC5132 module)
™
• Local PCLINK and remote upload/download
capability
- PCLINK allows direct connect of PC
to alarm panel
- program system using DLS software
- view status and trouble conditions
- view 128 event buffer
• 700mA supervised bell output
At DSC, we don’t like false alarms any more
than you do, so the PC580 and PC1555 have
over a dozen sophisticated SIA false alarm
prevention features built into them.
Advanced
Communications
Digital
• All major formats including
SIA and Contact ID
and security systems
PC580
False Alarm Prevention
DVACS
offering the latest
• Optional function of PC5400 module
advances in hybrid
• Up to 32 zones using any combination of zones
available from:
- 6 hardwired zones on control panel
- 8 keypad zone inputs (1 per keypad)
- 32 wireless zones (with PC5132 module)
PC5132 Wireless Module
wireless/hardwired
burglary and fire
• 37 access codes
• 12 keypads…up to 8 hardwire keypads (any
mix of LCD and/or LED) and 4 wireless keypads
• 128 event buffer…time and date stamped
• 2 programmable voltage outputs:
- 1 high current PGM…300mA @ 12VDC
may also be used for 2-wire smoke
- 1 low current PGM…50mA
protection!
Compatible With All DSC Wireless
Controls and Detectors
Wireless Controls:
• WLS908 Wireless Panic Pendant*
• WLS909 Wireless Key
• WLS910 Wireless Keypad
Wireless Detectors*:
• WLS904 PIR Motion Detector
• WLS906 Photoelectric Smoke Alarm
• WLS907 Universal Transmitter
• Capacity … 32 wireless zones
… 16 WLS909 Wireless Keys
… 4 WLS910 Wireless Keypads
(in addition to hardwired keypads)
• All wireless detectors are fully supervised for
communication integrity
• 900 MHz True Spread Spectrum Technology
• Easy sensor enroll process
*each occupies 1 wireless zone
Wireless Communications
• Fully compatible with Sur-Gard’s
™
™
Links1000 and SKYROUTE
cellemetry transmitter
7438 C5
KEYBUS
Data Network
PC1555RKZ
PC5508Z
LCD5500Z
8 Zone LED Keypad
8 Zone LED Keypad
Dual-Language Message Keypad
• Zone input…connect detector to keypad
to create a keypad zone
• 5 programmable keypad functions
• LED indicators…Ready, Armed, System
• 4 keypad-activated alarms…Panic, Auxiliary, Fire, and Duress
• Backlit display…with Backlighting Boost
to provide extra high key lighting when
any key is pressed
• Piezo buzzer…provides audible feedback
for correct key entries, pre-alert, and
system trouble status
• Zone input…connect detector to keypad
to create a keypad zone
• 5 programmable function keys
• LED indicators…Ready, Armed, Trouble,
Memory, Bypass, Fire, Program
• 4 keypad-activated alarms…Panic, Auxiliary, Fire, and Duress
• Backlit display…with Backlighting Boost
for low light conditions
• Piezo buzzer…provides audible feedback
for correct key entries, pre-alert, and
system trouble status
•2•
• Display zone, system status,
•
•
•
•
trouble conditions, event buffer,
and system instructions
Large backlit, two line 32 character
display with Backlighting Boost for low
light conditions
Dual languages (any 2 from Eng. Fr. or Span.)…
simple key entry to toggle between
languages while viewing keypad
Zone input…connect detector to
keypad to create a keypad zone
5 programmable function keys
Event-Initiated Paging
• Built-in pager format
• 4 conductor, standard, non-shielded,
station wire communications bus for
connection of hardwired keypads,
printer interface module and wireless
interface module
• connect modules up to 1,000ft
(305m) from main control panel
PC5400
RS-232 Printer/DVACS* Interface
• Use as DVACS communicator or
printer interface (not both)
• Print time and date stamped report of:
alarms, openings/closings, and
diagnostic messages,
• Supports any 300, 1200, 2400,
4800 bps serial printer
* DVACS is a trademark of Electro Arts Ltd.
•3•
Long Range Radio
• Fully compatible with the
™
™
Links2150 & Links2450 radio
transmitters
TM
Optional Keypads
7 to21 Zone Fixed Size Hardwired Systems
™
From basic security with advanced features including Escort voice
®
prompting and Downlook still frame video transmission, economical
Classic systems meet a wide range of customer requirements
•
•
•
•
•
•
•
•
•
LCD Multi-Language Message Keypads
PC500
PC550
PC1550
PC1575
7 Zone Control With Keypad
- no digital communicator-
7 Zone Control
Communicator With Keypad
9 Zone Control
Communicator With Keypad
10 Zone Control
Communicator With Keypad
4 programmable zones
3 keypad zones
4 user codes
Up to 3 keypads
Keyswitch compatible
2 PGM outputs
Door chime, quick arming
Optional SL-40 keypad
With STD keypad - PC500RK
•
•
•
•
•
•
•
•
•
•
4 programmable zones
3 keypad zones
4 user codes
Up to 3 keypads
Keyswitch compatible
1 PGM output
Door chime, quick arming
Upload/download
Optional SL-40 keypad
With STD keypad - PC500RK
•
•
•
•
•
•
•
•
•
•
6 prog. zones • 3 keypad zones
Up to 3 keypads
6 user codes
One-time use code, quick arming,
quick exit, auto-arming
Split reporting
Optional Escort Voice Prompt
Upload/download
Opt. SL-60 & LED615 keypads
Optional LCD600 keypad
With STD keypad - PC1500RK
•
•
•
•
•
•
•
•
6 programmable zones
3 keypad zones
1 smoke or auxiliary zone
7 user codes
Up to 8 keypads
2 PGM outputs
Upload/download
Optional Downlook, Escort 5580,
DVACS, and printer
• Optional LCD5500 keypad
• Optional PC5506 and SL-75
LED keypads
• With STD keypad - PC1575RK
LCD5500
LCD600
™
Escort
Voice Prompt Module
Optional Keypad For
PC1575
Optional Keypad For
PC1550, PC2525, PC2550
& PC3000
• Turns any Touch-Tone* phone into a
fully functional keypad
• Choice of language – English, French,
or Spanish
• Compatible with PC1550, PC2525,
PC2550, & PC3000
• Large backlit, two line
32 character display
• Adjustable display contrast
for easy viewing in low
light conditions
• Plain language display
of system conditions
and messages
• Plain language instructions
for system operation
• Change language with
a simple key command
• Access to Event Buffer,
Time & Date Display on
LCD5500
LED Keypads
™
Escort 5580
Voice Prompt Module with Automation
Control for PC1575
• Turns any Touch-Tone* phone into a
fully functional keypad
• Choice of language – English, French,
or Spanish
• Built-in power line interface for up
to 32 X-10 control devices
•
•
•
•
•
•
•
•
•
•
•
PC2525
PC2550
PC3000
PC1150
11 Zone Control
Communicator With Keypad
13 Zone Control
Communicator With Keypad
21 Zone Control
Communicator With Keypad
7 Zone Control
Communicator With Keypad
8 programmable zones
3 keypad zones
8 user codes
Up to 3 keypads
One-time use code
Quick arming, • Quick exit
Auto-arming • Split reporting
Upload/download
Optional Escort Voice Prompt
Optional LCD600 keypad
Optional LED625 and SL-80
LED keypads
• With STD keypad - PC2550RK
•
•
•
•
•
•
•
•
•
•
•
8 programmable zones
3 keypad zones
Auxiliary. input zone
Supervised fire zone
16 user codes
Up to 3 keypads
Upload/download
2 partitions
Optional Escort Voice Prompt
Optional LCD600 keypad
Optional LED625 and SL-80
LED keypads
• With STD keypad - PC2550RK
•
•
•
•
•
•
•
•
•
•
•
•
16 programmable zones
3 keypad zones
Aux. Input zone
Supervised fire zone
16 user codes
Up to 3 keypads
Upload/download
2 partitions
Optional Escort Voice Prompt
Optional LCD600 keypad
Optional LED630 keypad
With STD keypad - PC3000RK
•
•
•
•
•
•
•
4 programmable zones
3 keypad zones
4 user codes
Auto-arming
Split reporting
Upload/download
Built-in keypad
PC5506
Optional Keypad For PC1575
• LED615 –
• LED625 –
• LED630 –
Optional Keypad for PC1550
Optional Keypad for PC2525
& PC2550
Optional Keypad for PC3000
• Attractive keypad door
protects and conceals keys
Slim-Line LED Keypads
Downlook
SL-40, 60/75, 80
®
Still Frame Video Transmission
for PC1575
• New slim-line
•
• Video capture, compression
& transmission from up to 4 video
sources for alarm verification
• Requires Sur-Gard DLM-4 Video Transmission Module and DLM-7 Camera
Expansion Module
(see page 26)
•
•
•
* Touch-Tone is a trademark
•4•
• LED indication of zone,
trouble and alarm status
• Backlit keys and display
for easy viewing in low
light conditions
of Stentor Resource Inc.
•5•
semi-flush keypad
Backlit LED zone
status indication
Colour LED alarm, trouble
and system status
Adjustable keypad
sounder & backlighting
Attractive styling
•
•
•
•
SL-40 for PC500 & PC550
SL-60 for PC1550
SL-75 for PC1575
SL-80 for PC2525,
& PC2550
• SL-40, 60, 75, 80
With backplate/zone label
(shown for SL-40)
®
WINNER
Product Achievement Award for
Intrusion Alarm Systems
8 to 32 Zone Expandable Hybrid Security System
Audio Station and Keypad mounted on a common backplate
Integrated
CCTV*
…packed with options that make Power832 the most innovative security system on the market today !
Integrated
HVAC Control
Integrated
Audio
Integrated
Automation
Downlook®
PC5010/5015Video PC5508Z/16Z/32Z
8 - 32 Zone Control Panel
• 8 programmable zones expandable
to 32 zones hardwired or wireless
• Supervised bell output
• One 2-wire smoke zone
• Up to 14 programmable outputs:
- 1 high current PGM (300mA)
- 1 low current PGM (50mA)
• 2 partitions
• 37 access code: 32 user codes,
2 partition master, 1 system master
code, 2 hold-up codes
• Upload/download
• 128 event buffer, time and date
stamped
PC5010 - Alarm only
®
PC5015* - Alarm plus Downlook
video control capability
8, 16 or 32 Zone LED Keypads
• Backlit keys and full annunciation
of system status
• 5 programmable function
keys with 18 options
• 4 keypad activated alarms (Panic,
Auxiliary, Fire, and Duress)
• Keypads individually
supervised for tamper
• Can be assigned as “global”
or “partition” keypad
• Connect up to 8 keypads,
combination of LED and/or LCD
PC5508 - 8 zone LED Keypad
PC5516 - 16 zone LED Keypad
PC5532 - 32 zone LED Keypad
Output Modules
LCD5500Z
Multi-Language Message Keypad
• Large backlit, two line
32 character display
• 5 programmable function
keys with 18 options
• Connect up to 8
keypads, combination
LCD and/or LED
• Plain language operation
• Keypad can be assigned
as “global” or “partition”
PC5204 - Power Output Module
• Provides 1 Amp @ 12VDC
aux power
• Includes 4 fully programmable
high current switched outputs
rated at 1 Amp @ 12VDC
• Output-1 also supervised bell output
PC5208 Voltage Output Module
• Provides 8 transistor switched
outputs rated at 50mA @ 12VDC
• 24 programmable output options
Zone Expansion
PC5108Alarm/5108L Video
Zone Expanders
• Expand system in 8 zone steps
• Full NC/EOL/DEOL supervision
• PC5108L is c/w 8 camera inputs
®
for Downlook
Intercom
& Central Station
Audio Monitoring
On-Site Sequential Switching
&
Still Frame Video Transmission
EMS-100
Thermostat
• Multi-stage auto-changeover
thermostat – 2 heat/2 cool
• Requires Escort PC5580TC
module
• System LCD keypads display
interior/exterior temperatures
• Control building heating/cooling
from system keypads
• Control building heating/cooling
from any local or remote
touchtone telephone
• Schedule heating/cooling via
Power832 Escort scheduling
• Interior/exterior sensors available
• Interior temperature sensor
averaging for control
Escort™ 5580
Telephone Access
Security & Building
Automation Control Module
• Turns any touch-tone phone
into a keypad with most
standard functions
• Module contains extensive
library of voice prompts
• Choice of language – English,
French, or Spanish
• Built-in Power Line
interface for up to 32
X-10 control devices
• Program up to 16 schedules
and 8 control modes
Local Intercom
• Requires PC5015 Control Panel &
PC5108L Video Zone Expander
• All necessary programming
software built in to PC5015
control panel
• PC5108L provides 8 video
inputs, one video output,
& 8 alarm zones
• May be used standalone as an
on-site video switcher
• Connect to Sur-Gard DLM-4L
Video Transmitter Module for
transmission to monitoring
station (see page 26)
™
Hand-held Demo
• Battery operated demo for
Power832 LCD keypad
• Demonstrates stay arm, away
arm, and disarming system
PC5132
Wireless Module
Compatible With All DSC Wireless
Controls and Detectors
Wireless Controls:
• WLS908 Wireless Panic Pendant*
• WLS909 Wireless Key
• WLS910 Wireless Keypad
Wireless Detectors*:
• WLS904 PIR Motion Detector
• WLS906 Photoelectric Smoke Alarm
• WLS907 Universal Transmitter
*each occupies one wireless zone
• Supports 32 wireless zones,
16 WLS909 Wireless Keys,
and 4 WLS910 Wireless Keypads
• All wireless detectors are fully
supervised for communication integrity
• 900MHz True Spread Spectrum Technology
• Easy sensor enroll process
• Wireless devices use standard
AA/AAA alkaline batteries
•6•
PC5400
RS 232 Printer/DVACS Interface
• Use as DVACS communications or printer
interface
• Print time and date stamped report of:
alarms, openings/closings, diagnostic
messages
• Supports any 300, 1200, 2400,
4800 BPS serial printer
Accredited Technician
Program
• 3Hr video library & companion
workbook
• Designed to make experts of
installers and salespeople
™
Laptop Demo
• The first demonstrator truly
designed for the dealer
• A hands-on demo of all system
features in an attractive, easy to
carry, dealer and customer
friendly package
•7•
• Select Zone, listen/talk,
extend on-line time, hang up
• Use up to 7 intercom stations
• Fully featured with
page/answer, do not disturb,
nursery listen-in, broadcast,
and door bell function
Central Station
Audio Monitoring
• operates via programmable
control tones from central station
PC5928 - Audio Interface Module
for intercom and Central
Station Audio Monitoring
PC5921 - Interior Station
PC5921EXT - Exterior Station
PC5921EXT-R - Exterior Station
with door chime relay
PC5904 - Two Way
Listen-In Station
®
MAXSYS
MAXS
YS
I n t e g r a t e d S y s t e m s Te c h n o l o g y
®
S Y
S T
E M
®
Security
Products
PC4010/4020
LCD4500/4501
Security Control Panels
Plain Language Keypads
PC4010
PC4020
• 8 zone main panel
• Expandable to 64 zones
• 1 addressable loop for up
to 56 addressable devices
• 16 LCD keypads/system
• 4 partitions
• 1,000 user codes
• 3,000 event buffer
• 5 account numbers
3 phone numbers
• 16 zone main panel
• Expandable to 128 zones
• 2 addressable loops for up
to 112 addressable devices
• 16 LCD keypads/system
• 8 partitions
• 1,000 user codes
• 3,000 event buffer
• 9 account numbers
3 phone numbers
• 1 supervised bell zone
™
• PCLINK for local
upload/download
• Remote upload/download
• Supervised digital
alarm communicator
• Opt. attack-resistant cabinet
• Space for two 7 AH
gel-cell batteries
• Two line, 32 character display
• Adjustable brightness & contrast
• Backlighting Boost on LCD4501
for low light conditions
• Display zone and system status,
trouble conditions, event buffer,
and system instructions
• Global or partition operation
• 4 keypad-activated alarms…
panic, auxiliary, fire, & duress
• 5 programmable keypad
functions
• Separate function keys on
LCD4501
• Trouble & Armed LEDs on
LCD4500
• Trouble, Armed, & Ready LEDs
on LCD4501
• Trouble buzzer
• Tamper versions available
PC4108A/4116
PC4204
8/16 Hardwire Zone Expansion Modules
Power Supply/Quad Relay Output Module
• PC4108A .... 8 zone input module
• PC4108AT .. 8 zone input module
with tamper (use with
PC5001CP cabinet)
• PC4116........16 zone input module
• 30 programmable zone types
• All zones programmable as NC , EOL , DEOL
• 250 mA, 12 VDC aux. power for local devices
• Add up to 56 zones on PC4010/CF
• Add up to 112 zones on PC4020/CF
• Up to 1.0A @ 12 VDC power for:
- COMBUS power - local input devices
- local output signals
• 4 form 'C' programmable relays
- contacts rated for 2 A @ 30 VDC
• 59 programmable output options
• Supervised for low/disconnected battery,
AC power fail, and Aux. supply fault
PC4010 .......... up to 16 modules per
system for 64 relays total
PC4020 .......... up to 16 modules per
system for 64 relays total
•8•
Use 2-wire addressable loops to easily
expand to full system zone capacity
without the added cost
of system expansion modules
COMBUS
System Expansion
PC4632/4664
• Hardwired system expansion is
simple and economical using
standard, non-shielded, 4
conductor station wire.
• All hardwired system keypads,
zone input modules, access control
modules, output modules, Escort
automation, fire modules,
annunciators, etc., are connected
to the system via the COMBUS.
• System components may be
connected up to 1,000ft (305m)
from the main control panel.
• Up to four 1,000ft runs can be used.
Addressable
Expansion*
• AMA-100 Glassbreak Detector
• AMS-220 Series…Photoelectric Smoke
Detectors
• AMB-300 PIR Motion Detector
• AMB-500 Ceiling Mount PIR
• AMB-600 Dual Pet Immune PIR
• AMP-700 Series…Contact Modules
(see page 14 for addressable device details)
32 & 64 Zone
Point/Graphic Annunciators
Point or graphic display of zone, partition,
and system status c/w:
• Egg-crate backplane for flexible indicator
location
• Pre-printed point display transparency
• Clear transparencies (2) for custom
graphic printing
PC4632 … 32 indicator capacity c/w:
• 8.5" x 11" (21.6 x 27.9cm) display area
• One PC4216 low power output module capacity for 2 modules
• 16 LEDs
• PC4032C cabinet, beige
PC4664 … 64 indicator capacity c/w:
• 11" x 17" (27.9 x 43.2 cm) display area
• Two PC4216 low power output modules capacity for 4 modules
• 32 LEDs
• PC 4064C cabinet, beige
PC4632FT … opt. flush trim for PC4632
PC4664FT … opt. flush trim for PC4664
Compatible With All
DSC Addressable Detectors
Wireless Expansion
PC4164 Wireless Module
Compatible With All DSC Wireless
Controls and Detectors
Wireless Controls:
• WLS908 Wireless Panic Pendant(1)
• WLS909 Wireless Key
• WLS910 Wireless Keypad
Wireless Detectors(1):
• WLS904 PIR Motion Detector
• WLS906 Photoelectric Smoke Alarm
• WLS907 Universal Transmitter
(1)
each occupies 1 wireless zone
• Capacity … Wireless zones - PC4010…56
- PC4020…64
… 16 WLS909 Wireless Keys
… 4 WLS910 Wireless Keypads
(in addition to hardwired keypads)
• All wireless detectors are fully supervised for
communication integrity
• 900 MHz True Spread Spectrum Technology
• Easy sensor enroll process
(see page 13 for wireless device details)
PC4216
16 Low Current Output Module
• 16 programmable output zones
• Outputs rated for 50 mA @
12 VDC
• 59 programmable output
options
• Up to 9 modules/system for
144 total outputs on
PC4010/CF and PC4020/CF
PC4400
RS 232 Printer/DVACS Interface
PS4350
• Use as DVACS communicator or printer interface
• Print time and date stamped report of: alarms,
openings/closings, diagnostic messages
• Supports 300, 1200, 2400, 4800 BPS serial printers
External Battery Charger
External battery charger c/w:
• PC4055C cabinet, beige
• PS4085 multi-rate charger module
• PT1012 transformer…12 VAC, 160 VA
• Space for 60 AH lead-acid battery
•9•
UL/ULC Listed Fire Systems*
Access
Control
MAXSY
S
PC4820
PC4010/4010CF
PC4020/4020CF
• 16 modules/system
• 32 readers total
• 1000 access cards
• 16 modules/system
• 32 readers total
• 1,000 access cards
• Full standalone operation
• Arm/disarm partitions & postpone
auto-arm by access card or access card
and code…from outside the protected
space
• 3 low current outputs per door
• 4 inputs per door…door contact,
request-to-exit input, arm, postpone
auto-arm
• 64 access levels
• 99 seven-day schedules
• 4 holiday groups - 730 holidays
• Individual door-unlock schedules
• Program via keypad, or via computer
with DLS-2 downloading software
• 1.5A regulated power supply
• Power capacity per door:
reader - 125 mA max. @ 5 VDC
or 250 mA max. @ 12 VDC
lock - 250 mA max. @ 12 VDC
• Auxiliary power -125 mA @ 12 VDC
• Battery required - 12VDC, 7.0 AH
• Transformer req’d - 16.5 VAC, 40 VA
• Fully supervised
Multiple Reader Technologies
POL-1 ....................
POL-1W ................
POL-2 ....................
POL-2W ................
POL-C1CN ..............
POL-1
SH-VR
POL-C1CN
SH-2
HID-PR5355KP
SH-K1
Plain Language Keypads
Security
Products
PC4010CF/4020CF
Fire Control Panels
Integrated
SYSTEMS
Technology
Automation
• PC4701 Fire Module:
… one 2-wire Class B / Style B
supervised smoke zone
… one Class B / Style B
waterflow zone
… dual supervised digital alarm
communicator outputs
… common fire alarm & fire
trouble relays, form 'C', 2 A,
30 VDC contacts
• All panel & expansion zones are
configurable for: fire, waterflow,
or fire supervisory
• 16 VAC, 40 VA transformer
Digital
• 4 communications formats…
high speed pulse (1400 &
2300 bps), Contact ID, and SIA
Identical to the standard security keypads
but with…red bezels
DVACS
All the security features of the
PC4010/4020 plus additional fire
features…
Reader – indoor
Reader – outdoor
Reader & keypad – indoor
Reader & keypad – outdoor
Mag-stripe card
• Alternate function of PC4400
module
PC4702BP
Dual Bell Zone Panel
• 2 alarm notification circuits
- rated for 1.8A @ 24 VDC - FWR
• Outputs supervised for opens, shorts,
and ground fault
• Self-restoring short circuit protection
• PT1024 transfmr incl…28VAC, 160 VA
• PC4052CR cabinet, red
• Space for two 4 AH gel-cell batteries
PC4010CF ...... 4 panels / system
for 8 bell output zones total
PC4020CF ...... 4 panels / system
for 8 bell output zones total
Wireless Communications
• Fully compatible with Sur-Gard’s
™
Links1000 cellular transmitter
™
and SKYROUTE cellemetry
transmitter
ShadowProx…Proximity Readers/Cards
SH-VR.................... Std size reader. – indoor/outdoor
SH-1 ...................... Slim-line mullion size reader
4" (10cm) range – indoor/outdoor
SH-2 ...................... Wall-switch size reader
4" (10cm) range – indoor/outdoor
SH-5 ...................... Reader 16" (40cm) range – indoor
SH-5EXT................ Reader 16" (40cm) range – outdoor
SH-C1 .................... Proximity card
SH-K1.................... Proximity keytag
HID…Proximity Readers/Cards
SH-C1
LCD4520/4521
®
Polaris…Mag-Stripe Readers/Cards
• 26 bit standard Wiegand…plus
®
S Y
S T
E M
Two Reader Access Control Module
Advanced
Communications
HID-MP5365.......... Slimline reader
4-5" (10-13cm) range – indoor
HID-PR5355 .......... Reader 5-9" (13-23cm) range
– indoor/outdoor
HID-PR5355KP.. .... Reader w/keypad 5-9"
(13-23cm) range – indoor/outdoor
HID-C1325KSF ...... Proximity card
HID-C1345KSF ...... Proximity keytag
T.Rex…Infrared Exit Detectors
KT-TREX-XL ...... Complete with piezo buzzer & tamper
KT-TREX-LT........ No piezo, no tamper
• 10 •
Escort4580
Voice Prompt
Security & Building
Automation Control Module
• Turns any touch tone phone
into a fully functional keypad with
both Global and Partition control
• Module contains extensive
library of voice prompts for security
and building automation control and
status feedback
• Up to 6 words per voice prompt,
chosen from a 241 word library
• Built-in Power Line interface for
up to 32 X-10 control devices
• Program event activation of X-10
devices using up to 16 schedules
7438 C5
PC4612
12 Zone Fire Annunciator
• point annunciation of…
- 10 fire zones
- 2 supervisory zones
- common zone trouble
- common bell trouble
- system trouble
- AC ON LED
PS4350R
Fire System External Battery Charger
External battery charger c/w:
• PC4055CR cabinet, red
• PS4085 multi-rate charger module
• PT1012 transformer…12 VAC, 160 VA
• Space for 60 AH lead-acid battery
PC4204CF
Power Supply/Quad Relay Output Panel
• Up to 550mA @ 12 VDC power for:
- COMBUS power - local input devices
- local output signals
• 4 form 'C' programmable relays
- contacts rated for 2 A @ 30 VDC
• 59 programmable output options
• Supervised for low/disconnected battery,
AC power fail, and aux. supply fault
• PT1016 transfmr. incl…16 VAC, 40 VA
• PC4052CR cabinet, red
• Space for one additional PC 4108A module
• Space for two 7 AH gel-cell batteries
PC4010CF ...... up to 16 modules per
system for 64 relays total
PC4020CF ...... up to 16 modules per
system for 64 relays total
• 11 •
Event-Initiated Paging
• 3 built-in pager formats
Long Range Radio
• Fully compatible with the
™
™
Links2150 & Links2450 radio
transmitters
™
For use with:
Wireless
Control
Wireless Control
™
™
®
Hybrid Wireless Security Systems
900MHz Spread Spectrum
MARQUIS ™ is a full 900MHz Spread Spectrum
wireless system that can be installed in minutes and
provide years of reliable, maintenance free service.
WLS900
#1…direct to controller
#2…through sounder to controller
• Only one path has to be open to
complete a transmission
CONTROLLER
PATH
1
WLS910
Wireless Key
Keypad
WLS901
WLS902
WLS903
System Controller
Plain Language Keypad
Sounder/Repeater
• 10 zones
• 10 user codes
• Built-in digital communicator
with telephone jack
connections
• Fully supervised for:
- tamper
- low battery
- device fault
- AC failure
- telephone line integrity
• AC adapter supplied
• 1.2AH sealed battery supplied
• Full 2 way communications
• 2 keypads per system (max.)
• Large 32 character display
backlit for low light conditions
• 3 emergency keys (F, A, P)
• Module placement
test mode reporting
• Fully supervised for:
- tamper
- low battery
- device fault
• 4 AA batteries supplied
• Siren and audible annunciator
• 85dB adjustable siren volume
• Back-up signal repeater between
wireless devices and controller
• 2 per system (max.)
• Door chime
• Fully supervised for:
- tamper
- low battery
- device fault
- AC failure
• AC adapter supplied
• 4 AA alkaline batteries supplied
• 4 programmable function
buttons of users choice such as
STAY arm, AWAY arm, Disarm,
Fire, Auxiliary, Panic,
Automation functions
• 3 A76 batteries supplied
• Performs most hardwired keypad functions, incl.
entry of access code to arm / disarm system and
other functions incl.: STAY arm, AWAY arm, F, P, A,
Chime On/Off, System Test, Utility Output, Reset,
Quick Exit, Reactivate Home/Away, PGM1 &
PGM2 outputs*
• Keys 1-4 are programmable func. keys
• Separate F, A, P, keys
• Supervised for low battery
• 3 AAA batteries (supplied)
900MHz
Wireless
Detection
Wireless Detection
Spread Spectrum wireless technology is superior
for security applications because it provides the proven reliability of
multiple frequency signal transmission and the high security of an
encoded signal. Spread spectrum also provides more frequent
supervisory communications between the control panel and
sensor…a critical issue in the protection of lives and property!
Compatible With All DSC Wireless Detectors*
DETECTOR
• WLS904 PIR Motion Detector
• WLS906 Photoelectric Smoke Alarm
*each occupies one wireless zone
• WLS907 Universal Transmitter
Reliable Installation & Testing
PATH
WLS909
Panic Pendant
• Press 2 buttons for 2 seconds
to transmit a panic alarm to
the monitoring station
• Water resistant
• Sealed non-replaceable battery
True Diversity
RF Communications:
• Each transmitter has two paths
to the controller:
WLS908
• module placement test mode
- allows installer to carry a keypad to the proposed location for a system module (sounder, keypad, detector)
and test communications to the controller before the
module is installed. Keypad reports whether proposed
location is “good”, “fair” or “bad”.
2
• walk test mode
- allows installer or user to test device placement
• sounder test mode - tests sounder operation
SOUNDER
• manual dialer test mode
- tests dialer communication to monitoring station
WLS904
WLS906
WLS907
Passive Infrared Detector
Photoelectric Smoke Detector
Slim-Line Transmitter
• Proven detector design
• 4 interchangeable lenses
- wall to wall - corridor
- curtain
- pet alley
• Lens coverage same as
Bravo3 (pg. 15)
• High traffic shut-down
• Fully supervised for:
- tamper
- low battery
- device fault
• 4 AAA batteries (supplied)
• Exclusive 90 degree smoke
detection pattern
• Automatic self test
• Manual test button
• Loud 85dB alarm horn
• Fully supervised for:
- tamper
- low battery
- device fault - low sensitivity
• ULC listed S531,
UL listed UL217 & UL268
• 6 AA batteries (supplied)
™
For use with:
Standalone Wireless Security System
• 12 •
• May be used as a magnetic door or
window contact or terminal
connection for an external contact
• 2 reed switch contacts for ease of
placement
• Fully supervised for:
- tamper
- low battery
- device fault - open/close
• 3 AAA batteries (supplied)
™
™
®
Hybrid Wireless Security Systems
• 13 •
Addressable
Addressable
Detection
Detection
Power & Communications
via
Two-Wire Addressable Multiplex Loop
TM
For use with:
®
PIR Motion Detectors
A full line of Bravo passive infrared motion
detectors stand ready to offer the precise
performance and value your next security
installation demands. Advanced signal
processing, automatic temperature
compensation and proven immunity to
white light and electrical transients.
AMS100
Acuity Glassbreak Detector
• Exceptional microphone frequency
range provides excellent sound capture
at low sound levels and distances up to
25 ft (7.6 m)
• (see Acuity, pg 19 for range table)
• Detects all common types of framed
glass including plate, wired, tempered,
and laminated
• Built-in tamper switch
• AFT-100 Glassbreak Tester ensures
reliable installation and response
AMS220 Series
AMB300
Photoelectric Smoke Detectors
Passive Infrared Motion Detector
AMS-220… .... 2-wire smoke detector
AMS-220T… .. includes 135°F (57°C)
fixed temp. heat sensor
• Advanced 90° detection pattern
• Red solid-state LED indicator light
• magnet-activated sensitivity
test switch
• continuous self-test for low sensitivity
• manual and programmable scheduled
tests for low sensitivity and alarm
operation
• locking/non-locking mounting plate
• Multi-level PIR signal processing
• Single element low noise sensor
• Built-in tamper switch
LENS COVERAGE
Wall-to-Wall Lens
(BV-L1) . . . .50'L x 60'W
Corridor Lens
(BV-L2) . . . .120'L x 10.5'W
Curtain Lens
(BV-L3) . . . .50'L x 4.4'W
Pet Alley Lens
(BV-L4) . . . .50'L x 60'W
(15.2 x 18.3m)
(36.6 x 3.2m)
(15.2 x 1.3m)
The Bravo2 Standard-Range PIR
is ideal for residential security
systems and all normal office &
commercial installations.
(15.2 x 18.3m)
MODELS
AMB600
Dual Element Pet Immunity PIR
• The addressable version of DSC’s
Bravo6 Pet Immunity detector (pg. 17)
• Multi-level PIR signal processing
• Two dual-element low noise sensors
• High static and transient protection
• High white light & RF immunity
• Temperature compensation
• LED on/off jumper
LENS COVERAGE
Dual PIR Lens Pattern
. . . . . . . . .40'L x 50'W
AMP700 Series
Contact Modules
AMP-701… .. 3 inputs to monitor
external NC alarm,
tamper, and trouble
contacts
COM
STR-
PGM
STR+
Connect unused inputs to GND
TAM
IN
ALM
COM
TBL
NOTE : Do not use more than
3ft (1m) of cable to connect
an external device to the AMP-701
To next addressable device
COM
STR-
AMP-700 ...... magnetic door and
window contact
GND
PGM
STR+
COM
GND
(12.2 x 15.2m)
To next addressable device
• 14 •
Tamper Switch
IN
The Bravo3 Long-Range PIR can
be used for all residential, commercial
and industrial applications requiring
longer range sensing capability
without compromising accuracy.
The Bravo4 ‘Quad PIR’ is
designed for commercial, industrial
& institutional environments that
experience abnormally severe or
volatile conditions.
Form 'A' alarm contact
BV-200
BV-300
BV-400
Form 'A' alarm contact,
tamper, extra terminal
BV-200R
BV-300R
BV-400R
Form 'A' alarm contact,
& tamper
BV-201
BV-301
BV-401
Form 'C' alarm contact
& tamper
BV-202
BV-302
BV-402
LENS COVERAGE
Wall-to-Wall lens
(BV-L1)
40'L x 40'W
(12.2 x 12.2m)
50'L x 60'W
(15.2 x 18.3m)
50'L x 60'W
(15.2 x 18.3m)
Corridor lens
(BV-L2)
70'L x 6'W
(21.3 x 1.8m)
120'L x 10.5'W
(36.6 x 3.2m)
60'L x 5'W
(18.3 x 1.5m)
Curtain lens
(BV-L3)
40'L x 3.5'W
(12.2 x 1.1m)
50'L x 4.4'W
(15.2 x 1.3m)
50'L x 4.4'W
(15.2 x 1.3m
Pet Alley lens
(BV-L4)
40'L x 40'W
(12.2 x 12.2m)
50'L x 60'W
(15.2 x 18.3m)
50'L x 60'W
(15.2 x 18.3m)
Reed Switch
Local magnet next to reed switch
• 15 •
TM
TM
Superior Pet Immunity
Detector
Ceiling-Mount
360°PIR
Motion Detector
BV-500
Form 'A' alarm contact
BV-501
Form 'A' alarm contact & tamper switch
Where office partitions and room furniture offer
convenient hiding places, ordinary wall-mounted
detectors are at a disadvantage. Not so with Bravo5.
From its vantage point high up on the ceiling, it sees
where other detectors can't. And where street access
offers easy entry points, Bravo5 offers an optional
glassbreak detector, for double the protection.
BV-502
Form 'C' alarm contact & tamper switch
360° QUAD Element PIR…at 8' (2.4m) height
MODELS…Motion Alone
Introducing Bravo6 Dual Element PIR from DSC.
A new detector that’s going to change your expectations
for stability, sensitivity and cost effectiveness. Not just a
detector for harsh environments, Bravo6 offers a
new level of detector performance your business
can depend on in every security installation.
Features common to Bravo2, 3, 4, & 6:
•
•
•
•
Top View
15' / 4.6m
MODELS…Motion & Glassbreak
Multi-level PIR signal processing
Low noise sensors
Temperature compensation
High level static and transient protection
•
•
•
•
Exceptional white light immunity
Excellent RF immunity
LED on/off jumper
Super quiet operation
Multi-Level Dual PIR Lens
BV-500GB Form 'A' alarm contact (motion), form 'C' contact (glassbreak)
• Wall/corner mounting
• Attractive styling for any decor
• 5 year warranty
MODELS
Top View
BV-501GB Form 'A' alarm contact (motion), form 'C' contact (glassbreak)
& tamper switch
5' / 1.5m
BV-502GB Form 'C' alarm contact (motion), form 'C' contact (glassbreak)
& tamper switch
0
40'
12.2m
BV-600
Form ‘A’ alarm contact
BV-601
Form ‘A’ alarm contact & tamper switch
BV-602
Form ‘C’ alarm contact & tamper switch
5' / 1.5m
360° PIR DETECTOR RANGE
LENS COVERAGE
Mounting height
8' (2.4m)
10' (3.0m)
12' (3.6m)
Detection
diameter at floor
24'(7.3m)
30'(9.2m)
40'(12.2m)
15' / 4.6m
15'
4.6m
5'
1.5m
Top Lens
0
5'
1.5m
Dual PIR lens pattern . . . . . . .40'L x 50'W (12.2 x 15.2m)
15'
4.6m
Middle Lens
Bottom Lens
Side View
0
360° GLASSBREAK DETECTOR RANGE
Plate/Tempered
1⁄8" - 1⁄4" thick
(3 - 6mm)
18" x 18" and up
(46 x 46cm)
12" x 12" to 18" x 18"
(30 x 30 to 46 x 46cm)
25'
(7.6m)
15'
(4.6m)
15'
(4.6m)
10'
(3m)
18" x 18" and up
(46 x 46cm)
12" x 12" to 18" x 18"
(30 x 30 to 46 x 46cm)
20'
(6m)
10'
(3m)
DO
NOT
USE
25'
7.6m
8' / 2.4m
10' / 3m
5'
1.5m
20'
6m
0
5'
1.5m
20'
6m
360° Glassbreak Detector
D
• 16 •
25'
7.6m
Side View
PIR 1 – T op Lens
PIR 2 – Bottom Lens
7.5'
2.3m
D
Floor
†Jumper selectable
0
(For clarity, overlapping beams are not shown)
12' / 3.6m
Window
Wired/Laminated
1⁄4" thick
(6mm)
Sizes
Maximum 'D'
Detection Range
Level 1†
Level 2†
Window
Glass Type
& Thickness
5'
1.5m
5'
1.5m
Multi-level signal processing with
a vertically interleaving beam pattern
Bravo6 utilizes 2 dual element PIRs featuring High
Density Digital Analysis* and multi-level signal
processing with a vertically interleaving beam pattern
for superior intruder detection while being immune to
pets weighing up to
85lbs/38kg.
Nothing tells the
difference better
than Bravo6.
40'
12.2m
*patent pending
• 17 •
®
TM
Dual Technology
PIR/Microwave
Detectors
Digital Glassbreak
Detectors
Not just a new glassbreak detector, Acuity is a
breakthrough in glassbreak detection technology.
In fact, Acuity offers Dynamic Sound Analysis a detection system so innovative it’s recognized
by two patents.
Force2 offers two independent, high
quality motion detection systems - the
perfect integration of passive infrared
and microwave technology in a single
detector package. For great design,
superior intruder catch and exceptional
stability, choose Force2.
Features common to all Force2 detectors:
• High RF immunity with SMD
construction
• Exceptional white
light immunity
• Microcontroller low
voltage reset circuit
• Optional Form 'C' alarm contacts
• Optional tamper switch
• Multi-level PIR signal
processing**
• Digital Microwave
signal processing
• DRO microwave technology
for low current and reliable
operation
• MOV transient/static protection
BRACKETS
• Exceptional microphone
frequency range provides
excellent sound capture at
low sound levels and
distances of up to 12m (25ft).
• Jumper-selectable
sensitivity range.
MODELS
F2-200,
210, 220
Form 'A' alarm contact
F2-201,
211, 221
Form 'A' alarm contact & tamper switch
F2-201R, 211R, 221R
Form 'A' alarm contact & tamper switch & relay
F2-202,
Form 'A' alarm contact & tamper switch
F2-210/11/12
212, 222
F2-200/01/02
30'
9m
20'
6m
30'
9m
20'
6m
10'
3m
10'
3m
10'
3m
T
O
P
T
O
P
0
10'
3m
10'
3m
20'
6m
20'
6m
30'
9m
20'
6m
10'
3m
20'
6m
30' 40'
9m 12m
S
I
D
E
0
10'
3m
5'
1.5 m
10'
3m
20'
6m
30' 40' 50'
9m 12m 15m
S
I
D
E
Microwave
Infrared
T
O
P
0
10'
3m
30'
9m 0
10'
3m
5'
1.5m
AFT-100
Glassbreak Simulator
F2-220/21/22
30'
9m
20'
6m
0
30'
9m 0
10'
3m
5'
1.5 m
10'
3m
20'
6m
30'
9m
• portable, battery operated tester
ensures reliable locating and testing
of Acuity Glassbreak Detectors
• generates Plate or Tempered
Glass sound samples
• 7.62cm (3") full range speaker accurately
reproduces the full range of frequencies
generated by shattering glass
• single or automatic/continuous sound
(sound every 10 sec) operation
30 x 40ft (9 x 12m)
40 x 50ft (12 x 15m)
10 to 40ft (3 to 13m)
over entire operating range
• 18 •
AC-100
Form ‘A’ alarm contact
AC-101
Form ‘A’ alarm contact & tamper switch
AC-102
Form ‘C’ alarm contact & tamper switch
DETECTION RANGE
Glass Type
Plate/Tempered
1⁄ 1⁄
8 - 4" thick
(3 - 6mm)
40' 50' 60' 70' 80'
12 m 15 m 18 m 21m 24m
S
I
D
E
Opposite Wall Mounting
D
Coverage (max.L x max.W):
Microwave range adjust:
Temperature compensation:
• Exceptional detection
• Digital signal processing
of all common types of framed
analyzes sound in remarkable
glass including; plate, wired,
detail to provide greater detector
tempered and laminated.
sensitivity and immunity to
false alarms.
• Detectors accommodate
changes in frame construction,
• High static and transient
glass thickness and
protection includes reliable
MOV circuitry.
room acoustics.
MODELS
Ceiling Or Wall
• For use with all BRAVO
& FORCE2 detectors
• Adjustable universal joint
bracket
• Easily installed
• High impact white plastic
to match detector
• DM-W
Wall mount bracket
(not shown)
• DM-C
Ceiling-mount bracket
Features common to all Acuity detectors:
• Digital temperature compensation
(F2-200, F2-220 only)
• Adjustable microwave
detection pattern to match room
size (F2-200, F2-220 only)
**patent pending
70 x 60ft (21 x 18m)
30 to 70ft (9 to 21m)
over entire operating range
Adjacent Wall Mounting
Ceiling Mounting
Wired/Laminated
1⁄4" thick
(6mm)
D
D
D
D
D
†
Windows
Windows
Windows
• 19 •
Jumper selectable
Sizes
Maximum 'D'
Detection Range
Level 1† Level 2 †
18" x 18" and up
(46 x 46cm)
25'
(7.6m)
15'
(4.6m)
12" x 12" to 18" x 18"
(30 x 30 to 46 x 46cm)
15'
(4.6m)
10'
(3m)
18" x 18" and up
(46 x 46cm)
20'
(6m)
12" x 12" to 18" x 18"
(30 x 30 to 46 x 46cm)
10'
(3m)
DO
NOT
USE
MN-140 SERIES - DC POWERED SMOKE ALARM
™
•
•
•
•
•
•
WIRING
DIAGRAM
V+
V–
NO
+ I
MN-140
Form 'A' alarm relay, sounder, interconnect
MN-140T
As MN-140 plus 57oC (135oF) sensor
MN-140R
As MN-140 plus Form ‘C’ auxiliary relay
MN-140RT
As MN-140 with Form ‘C’ auxiliary relay, 57oC (135oF) sensor
MN-140C
Form ‘C’ alarm relay, sounder, interconnect
MN-140CT
As MN-140C plus 57oC (135oF) sensor
MN-140CH
As MN-140C plus isolated 57oC (135oF) sensor as
heat detector with Form ‘A’ relay
COM
I/O
NO
NC
COM
I/O
NO
NC
+ I
COM
• User verification of sensitivity
• Solid-state LED indicator light
• Locking/non-locking
mounting plate
• Attractive styling for any decor
• UL and ULC listed
NU
I/O
• Multi-level PIR signal processing
• Advanced 90° photoelectric detection pattern
and patented smoke chamber for superior
detection and dust resistance
• Unique high signal-to-noise ratio and superior
RFI immunity to prevent false alarms
• Excellent smoke access provides reliable detection
for all smoke flow directions and velocities
NO
+ I
Meridian is setting a new standard for
reliability and performance with a photoelectric
design so revolutionary it’s covered by two
patents. With 2-wire, 4-wire and wireless
versions, and all the options for relay type,
local sounder and fixed temperature sensor,
Meridian is ready for your next security or
fire alarm installation.
•MODELS
To
Interconnected
Units
12 to 24 VDC
COM
Photoelectric
Smoke Detectors
& Alarms
•
•
•
GREEN solid-state LED indicator light
Loud 85dB piezoelectric alarm sounder
Interconnect up to 20 detectors
Removable terminals for easier wiring
Optional Form ‘A’ (normally open, alarm closed) and/or Form ‘C’ (normally
open/normally closed) alarm relays
57oC (135oF) fixed temperature heat sensor option
Test Button for user to perform sensitivity test
Automatic self-test every 40 seconds with audible trouble indication if the
detector has insufficient smokesensitivity
ULC listed S531
To
Interconnected
Units
MN-220 SERIES - 2-WIRE SMOKE DETECTORS
• RED solid state LED indicator light
•MODELS
• Optional Form 'C' auxiliary relay
MN220
2-wire detector
MN220T
2-wire detector, fixed temp 135°F (57°C) sensor
• ULC listed S529/UL listed UL268
MN220R
2-wire detector, Form 'C' auxiliary relay
• Nominal operating voltage ................................12 - 24VDC or Vfwr
MN220RT
2-wire detector, Form 'C' auxiliary relay,
fixed temp 135°F (57°C) sensor
• 57°C (135°F) fixed temperature heat sensor option
• Magnet-activated sensitivity test switch
• Maximum operating volt. range ........................10 - 30VDC or 10 - 26.4Vfwr
WIRING DIAGRAM
V+
End of Line
Device
12 to 24 VDC
V–
Advanced 90° Detection Pattern
++ I
++ I
++ I
AUX Relay
Patented Smoke Chamber Design
Detects Smoke – Not Dust
NO
NC
C
NO
NC
C
With its advanced 90° photoelectric detection pattern, Meridian offers
superior detection of smoldering or rapid growth fires under a broad
range of applications and changing environmental conditions.
AUX Relay
MN-240 SERIES - 4-WIRE SMOKE DETECTORS
Meridian’s exclusive detection pattern smoke chamber design cannot
be found in just any ordinary smoke detector. Meridian’s design offers
greater sensitivity to smoke while at the same time better immunity to
dust, insects and other environmental factors - conditions that may
leave a lesser quality smoke detector impaired and unable to
alert you to danger.
• RED solid state LED indicator light
•MODELS
• Audible trouble indication (in sounder-equipped units)
if the unit has insufficient smoke sensitivity
MN240
Form 'A' alarm relay
• ULC listed S529/UL listed UL 268
MN240T
Form 'A' alarm relay, fixed temp 57°C (135°F) sensor
• Nominal operating voltage ................................12 - 24VDC or Vfwr
MN240R
Form 'A' alarm relay, Form 'C' auxiliary relay
MN240RT
Form 'A' alarm relay, Form 'C' auxiliary relay,
fixed temp 57°C (135°F) sensor
MN240S
Form 'A' alarm relay, 85dB sounder
MN240ST
Form 'A' alarm relay, 85dB sounder,
fixed temp 57°C (135°F) sensor
MN240SR
Form 'A' alarm relay, 85dB sounder, Form 'C' auxiliary relay
MN240SRT
Form 'A' alarm relay, 85dB sounder, Form 'C'
auxiliary relay, fixed temp 57°C (135°F) sensor
• Maximum operating volt. range ........................10 - 30VDC or 10 - 26.4Vfwr
Heat Detector Option
WIRING DIAGRAM
In addition to its superior ability to detect smoke, Meridian offers you
yet another critical safeguard - it is available with a built-in sensor
designed to detect the presence of heat caused by a fire that starts
and develops very rapidly.
V+
End of Line
Device
12 to 24 VDC
V–
++ I
C
NO
++ I
C
NO
C
NO
++ I
Alarm
Initiating
Circuit
With a quick glance at the LED indicator located at the top of your
Meridian unit, you can see in an instant if the smoke detector is ‘on’
or its alarm/trouble/normal status.
AUX Relay
• 20 •
NO
NC
C
NO
NC
C
Status Indicator
AUX Relay
EOL
Resistor
• 21 •
™
Integrated
Te l e p h o n e S y s t e m
by
®
8 lines
24 stations
voice mail
call management
intercom
computer/fax
interface
security system
management
building automation
management
infrared control
FCC Class A&B
certified
CPU-BRD
Digital KSU
Provides processing for the entire system and has
integral capability to provide a basic
communications system complete with:
• 8 digital stations
- 8/24 digital telephone stations, internal
intercom stations, door intercom
stations, and dual analog interface
stations
• 2 telephone lines
• 100 caller ID log of name*, number*, time and
date of call
• 4 programmable outputs
- program to operate when any or a
selected line rings, when a page is
performed, or to activate an electric lock
from any phone or internal or external
intercom station while a door station is
being answered,mobile telephone,etc.
• RCA input for an external source of system
background music, music on hold, and advertisement on hold
• Paging output for external warehouse or pool
speakers
• Emergency jack on line 1 for backup
analog phone
• Super-cap memory back-up
• Overcurrent, transient, and lightning/surge circuit protection
*Requires subscriber activation of appropriate
local Telco service(s)
• 22 •
VPC-CRD
Digital Message Center Card
Included with KSU
• 24 private station mailboxes
+ 1 general system mailbox
• 1 user recorded greeting/mailbox
• 5 recordable system greetings
• 100 message buffer records
message, caller phone number*,
date, and time (*requires caller ID)
• 3 modes of telephone answering:
Normal, Night Sentry, and Automated Attendant
• Remote access…allows users to
remotely perform the following:
- retrieve messages
- security control
- all page
- room monitor
- automation control
- open electric lock
• PIN protection of remote access
• Toll saver by line and mailbox
• Broadcast message
• Conversation recording
(where permitted by authorities)
• Installed and ready to use
EKT-824
INT-STA
DOOR-STA
DAI-CRD
Digital Telephone Station
Digital Intercom Station
Digital Intercom Station
2 Port Interface Station
Digital to Analog Conector
• 8 incoming telephone line keys
• 24 DSS (direct station select) keys…
each key may be used to:
- communicate with another station
- perform a programmable security or
automation function
• 19 dedicated function keys including:
Security (requires VPM-CRD Security
Interface Card)…one-touch access to
Maxsys and Power832 for security
system control
Automation (requires VPM-CRD Security
Interface Card)…one-touch access to
Maxsys & Power832 for X-10 control
Fire, Auxiliary, Panic (requires VPM-CRD
Security Interface Card)…3 keys to perform
one-touch emergency calls through the
Maxsys & Power832 building security
systems.
Room Monitor…allows user to listen to
room activity through from aremote
station and initiate private hands-free
conversation with the occupants. This
feature can be PIN protected and
disallowed to selected stations.
Hands-free
Message Center
Call forward
DND/MIC mute
Conference
Clock
Volume Up/Dn PGM
Hold/music
Speed dial
All page
Redial
• 32 character alphanumeric backlit
display with adjustable brightness and
contrast for display of:
- caller ID
- line selected
- number dialed
- station dialed
- date & time
- directory info
- messages
- alarm clock
- trouble conditions
- program instructions
• 16 character programmable station and
line labels
• Backlit keys with adjustable brightness
• Multiple security PINs
• Prime line access
• Line ring and access
• Loud bell control
• Off-hook ring
• Ring line preference
• “Flash” call switching
• Line call-back
• Automatic hold
• Exclusive hold
• Hold and transfer recall
• Music on hold and transfer
• Executive over-ride
• Alarm clock
• Door release output
• Hearing aid compatible
• DTMF and pulse signalling
• Hands-free mic and speaker
• Hands-free mic and speaker
• Volume control
• Call forward…station can be
programmed to call forward to an
• All page/answer button…
off-premise number when door bell
- press to page all other stations;
is pressed
or to answer a page or incoming
• Doorbell button…
call with private conversation
- press to sound door chime at all
• Door answer/release button…
stations programmed to receive
- press to answer a doorbell
door chime
station or terminate a call
- may be answered by an internal
• Background music on/off control
intercom station or at a phone
• Do not disturb on/off…
station
programmable from the intercom
- conversations are private once
station or any 8/24 Digital Telephone
answered
Station
• Provides an interface to 2 analog
telephone devices such as:
- fax machines to send and receive
faxes. (requires VPC-CRD Digital
Message Center Card)
- computer modems to save a
separate phone line
- cordless and standard analog
phone sets
• Each DAI occupies a separate station
space with corresponding DSS key on
8/24 Digital Telephone Stations
REM-IRC Infrared Remote Control
• Hand-held control with 22 buttons and low battery indicator
• Control station functions including:
- hands-free
- door release
- paging
- security
- automation
- intercom
- message center
- redial
- tune radio
- hold/music
- volume control
- flash
- room monitor
- do not disturb
Feature Expansion
Capacity
Expansion
TUN-CRD
Digital Tuner Card
• Proprietary radio tuner
• Provides background music
and music on hold
• Can be tuned from any 8/24
phone station
VPM-CRD
4580/5580
Security & Automation
Interface Card
• Interface to Maxsys (4580) and
•
•
•
•
•
Power832 (5580) security
systems
Any phone station keypad can be
used as a security system keypad
and automation controller
Operates security system and
associated 'X-10' control devices
Provides voice prompts
for programming and operation,
and voice feedback of system
status reports
Provides off premises access to
system from any telephone in the
world
Security, automation, all call
page, silent room monitoring,
intercom and DISA
STA-CRD
Digital Station Card
• Adds 8 additional stations
per card
• Add up to 2 cards for 16
additional stations or 24
stations total
MOD-CRD
Modem Card
• Two RS 232 ports for
connection to on-site printers
• Print system diagnostic and
Station Message Detail
Recording (SMDR) reports
• perform factory remote
diagnostics
• 23 •
CO-CRD
Central Office Card
• Adds 2 additional telephone
lines per card
• Add up to 3 cards for 6
additional lines or 8 lines total
Wireless Communications
Central Station
Receivers
Links 1000
Cellular Alarm Transmitter
SKYROUTE
Wireless Communications
™
Features
• UL • ULC Approved
Sur-Gard multiplex digital, video and two way listen-in compatible receivers
provide more lines and formats, faster installation and service, and better call
processing for superior control.
The Skyroute transceiver provides wireless communication of event
conditions to the alarm monitoring facility utilizing the the Cellemetry/sm
Data Service. The Skyroute module comes in the form of a plug-in
module for all Power832, PC1555 and PC580 control panels, utilizing
the keybus technology to provide full reporting, ease of programming
and module supervision. Cellemetry/sm Service is a patented wireless
technology developed by Cellemetry LLC and is provided exclusively in
Canada by Mobility Canada cellular carriers.
• Uses standard and priority cellular telephone services available
nationwide.
• Compatible with most DSC security systems including:
-PC1500, PC1550 (v4.0 Software), PC1575 (v1.0 software)
-PC2525 (v1.0 software), PC2550 (v1.2 & newer software)
-PC3000 (v7.6 & newer software), PC4010, PC4020 (all versions)
-PC4020KT (all versions), PC5010 (v1.0 & newer software)
-PC1555 & PC580 (all versions), PC 5015 (all versions)
• Battery back-up to A.C. power
• Registration format eliminates the possibility of ESN theft
• On-board signal strength indicator
• Auxiliary input trigger
- for automatic in-house phone connection to a preprogrammed
phone number.-connect
any in house phone onto cellular network
• Jumper selection for DC power operation…ideal for commercial
trucks, buses, boats and RV’S
• Self monitoring of:
-loss of A.C. power, battery fault, cellular communication and
tampering
• Programmable with Sur- Gard Links1000 PGM v1.4 :
-cellular telephone number, home access I.D. and initial paging
channel
Features
Uses Wireless Cellemetry Network where available
Simple four wire keybus connection
Compatible with:
DSC PC5010 software version v1.XX; v2.02
DSC PC1555 software version v2.XX
DSC PC580 (all version)
DSC PC5015 software version v1.XX; v2.2X
Provides full event reporting through keybus connection
Module transmits event conditions in less than a second
Module mounts into existing control panel cabinet
Powered from the control panel, preventing the use of an additional
transformer and an additional battery
Full status from built-in LED's
- Signal strength indicator
maximum signal strength
good signal strength
acceptable signal strength
- Transmit/Receive status
- Transceiver status
normal operation
modem not responding
module not connected
fail to communicate
Fully programmable via control panel keypad
Specifications
Cellular Specifications
• Local cellular telephone network
• Frequency Range: 880 MHz to 889 MHz
• Supports all control panel communication features.
Power
SLR
MLRV-A
DRL2A
MLR2
Single Line Receiver
Downlook® Video Receiver Module
Digital Receiver Module
Multi-Line Receiver
• Multiple communication
formats
• Caller ID
• 256 event memory
• Desk mount
• Parallel & Serial outputs
• Compatible with MLR2
Digital Receiver Expandable to 14
modules
• Video and Serial output
• Processes slow
scan video images
• Output to PC
• Outputs to switch
time lapse VCR
• Available in PAL or NTSC
• Requires expansion cage MLRXV
or MLR2XV
•
•
•
•
2 digital lines
256 event memory per line
Expands MLR2 to 14 lines
92 communication formats
including: Contact ID, SIA, BFSK,
ITI, SIA Level 1, 2, 3, 8, 20,
Ademco Contact ID, Radionics,
Silent Knight FSK
• Caller ID
•
•
•
•
•
•
•
Expandable to 14 lines
92 communication formats
Caller ID
Built-in audio
256 event memory per line
Parallel & Serial outputs
®
Downlook video compatible
Installation
• Current with no A.C.:
1.1A transmitting 210mA not transmitting
• Current with A.C.:
280mA battery charged 680mA battery under charge 1.15A tranmitting
• RF power output: 3.0Watts max.
• Battery: 12V 4 Ah rechargeable sealed battery
• Transformer: 16.5VAC, 40VA
Module mounts at top right corner or bottom left corner of existing
control panel cabinet.
Antenna through knockout
Antenna can be remotely located using available extension kits
Module can be remotely located up to 1000 feet from the control via
keybus connection
Antenna
Antenna
• 3-5dB gain, TNC connector, cabinet or remote control
• Extension kits available:
LAE- 3…3 foot antenna kit, LAE-15…15 foot antenna kit, LAE25…25 foot antenna kit
3 – 5 dB gain, TNC connector
Extension kits available:
LAE-3, 3 foot antenna extension kit,
LAE-15, 15 foot antenna extension kit
LAE25, 25 foot antenna extension kit
Dimensions
Power Supply
• 11” x 11.8” x 3.3” (279 x 300 x 84mm)
12 VDC from Panel Keybus and 12 VDC from Bell+ circuit
Dimension
Weight
MLRX
MLRXV
CABINETS
MLR2-SP
Receiver Expansion Cage
Video Expansion Cage
Receiver Cabinets
Spare Parts Kit
• 19" Rack Mount
• Holds 2 DRL2A
receiver modules
• 19" rack mount
• Holds 4 - MLRV-A
receiver module’s
MLR2XV
Video/Receiver Expansion Cage
• 19" rack mount
• Holds 2 - MLRV-A modules
and 1 DRL2A module
• CSX 2 line desk
mount Non U.L.
• CS.6 line desk
mount U.L.
• CM.14 line desk
mount U.L.
• CL.14 line floor
mount U.L. (shown)
3.5" x 4.6" x 1.8" (85 mm x 115 mm x 45 mm)
• 6.5 lbs. (3Kg)
Weight
• 24 •
0.5 lbs. (0.2 kg)
• 25 •
CPM2............central processor module
DRL2A ........2-line digital module
DML2A ........backplane circuit board
DML4 ..........backplane circuit board
MCBL............telephone connection cable
CH6UF2 ......power ribbon cable
CH6UF3 ......data bus ribbon cable
Automated
Still Frame Video
Transmission System
This line of observation system equipment creates a
complete professional CCTV solution. Standard CAT5
cables and 2-way audio capability combine to provide
an easy-to-install plug and play expandable system
which requires less cabling and installation time.
®
Downlook integrates video with DSC alarm systems to provide positive alarm verification and a visual record of events for subsequent investigations.
DLM-4/4L
DLM-7
DLGB
PC 5108L
Video Transmitter Module
7 Camera Expansion Module
Video Grabber Board
Power832 Video Matrix Module
• Captures, compresses, and
transmits B&W still frame video
®
• Used on all Downlook
applications:
- DLM-4 with 8400DL,
PC1580, and PC3000DL
- DLM-4L for Power832
equipped with PC5015
control board
• Single 75ohm input for camera,
VCR, or video switcher
• PAL or NTSC operation
• 10.5 - 16VDC operation,
300mA @12VDC
• Connects to DLM-4
®
• Expands Downlook system to:
- 7 video inputs when used
with 8400DL
- 4 video inputs when used
with PC1580
®
- not used on Power832
• Provides camera switching when
used with DLM-4 rotary feature
• Plugs into computer ISA slot
• Cable connection to receiver
MLRV-A module to capture
®
Downlook video on a PC
• One DLGB required
per MLRV-A
• Includes PSA software to
display and manage
video images
• Requires dedicated 486 Pentium
with at least 8Mb ram, 1Mb
™
video ram, Windows 3.11
or 95, and a mouse or
touch screen
• 4 cards per PC
• Adds 8 video inputs, one video
output and 8 alarm zones to
®
Power832 equipped with
PC5015* control board
®
• All necessary Downlook
programming software
®
built-in to Power832
• May be used alone as an
on-site video switcher
DLC-1 Cabinet
OBS14 Remote
Observation System
®
DLM-4L required for video, capture,
compression and transmission to a
monitoring station
Video Recorders
Impact Quad Splitter
Our new line of video recorders, a complement
to our monitor series, has been made for high
performance. These recorders are capable of
reproducing high-resolution color or black &
white images, and provide advanced features such
as combined time-lapse and real-time recording.
Our video handling series offers multiplexers,
quad processors and video switchers. Easy to use,
reliable and versatile, this series optimizes the
customer's CCTV installations through intelligent
design and a high degree of programmability.
Universal Downlook® System
®
adds Downlook capability to any alarm panel
®
or…acts as a standalone Downlook system
DLM-7
up to 7
video sources
DSC 8400DL
DLM-4
8 Channel Digital Communicator
PS3085
Power Supply
®
8400DL
up to 7
control
inputs
Optional
Alarm Panel
PS3085
Telco
Telco
• Built-in Downlook program
• 7 N/O or N/C alarm inputs
®
• programmed for Downlook
via DSC PC2550RK keypad
• Communicates alarm
and video information
• 3 outputs
• Built in telephone line monitor
DLM-7 provides 7 video inputs
triggered from inputs to 8400DL
DLM-4 provides video, capture,
compression and transmission
to a monitoring station
• 26 •
• Provides 3A, 12VDC power
for the 8400DL, DLM-4,
and DLM-7
• Supervisory outputs for
low battery and AC failure
• 16VAC transformer required
DLC-1
BG100
Ellipse Concealed Cameras
Our camera housing series has been designed for
indoor, outdoor, ceiling- or wall-mount installation.
The series is adaptable to a wide range of
installation conditions in the harshest environments,
and each has been designed to be user-friendly,
simple to install and easy to maintain.
Our dome series presents a versatile line of full or
half sphere domes engineered for easy installation
and maintenance. The domes are capable of housing
up to four PCB cameras and are extremely durable.
Adaptable to many different applications, they can be
recessed, flush-, pole- or wall-mounted.
Universal System Cabinet
• Houses 8400DL, PS3085,
DLM-7, and DLM-4
• 27 •
PC
15
55
Po
w
er
83
2
PC
40
10
PC
40
20
M
ar
qu
is ™
MODEL
PC
11
50
PC
15
50
PC
15
75
PC
25
25
PC
25
50
PC
30
00
PC
58
0
PC
50
0
PC
55
0
®
Control Panel
Feature Chart
# Programmable Zones
4
4
4
6
6
8
8
16
4
6
8
8
16
10
Expandable to
–
–
–
–
–
–
–
–
8
8
32
64
128
–
Wireless Option
–
–
–
–
–
–
–
–
l
l
l
l
l
l
Addressable
–
–
–
–
–
–
–
–
–
–
–
l
l
–
# Transistor Outputs
2
1
1
1
2
1
1
1
2
2
2
1
2
–
Expandable to
–
–
–
–
–
–
–
–
–
–
14
144
144
–
# Relay Outputs
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Expandable to
–
–
–
–
–
–
–
–
–
–
–
64
64
–
Swinger Shutdown
–
l
l
l
l
l
l
l
l
l
l
l
l
–
# Access Codes
4
4
6
6
7
8
16
16
37(1)
37(1)
37(1)
1,000
1,000(1)
10
# Partitions
1
1
1
1
1
1
2
2
1
1
2
4
8
1
–
–
l
l
l
l
l
l
l
l
l
l
l
–
Keypad Included…PC -
500RK
500RK
Integrated
1500RK
1575RK
2550RK
2550RK
3000RK
1555RKZ
1555RKZ
LED (2)
–
–
WLS902
Digital Communicator
no
l
l
l
l
l
l
l
l
l
l
l
l
l
–
–
–
–
l
l
l
l
l
l
l
l
l
l
Split Reporting
Telephone Line Monitor
Siren Circuit Supervision
–
–
–
l
l
l
l
l
l
l
l
l
l
l
Max. # of Keypads
3
3
1
3
8
3
3
3
8
8
8
16
16
2
LCD Keypad Available
–
–
–
l
l
l
l
l
l
l
l
l
l
l
Keyswitch Arming
l
–
–
–
l
l
l
l
l
l
l
l
l
–
Auto Bypass
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Auto Arming
–
–
l
l
l
l
l
l
l
l
l
l
l
–
Quick Exit
–
–
l
l
l
l
l
l
l
l
l
l
l
l
Keypad Programmable
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Downloadable
–
l
l
l
l
l
l
l
l
l
l
l
l
l
Ans. Machine Bypass
–
l
l
l
l
l
l
l
l
l
l
l
l
l
–
–
–
l
l
l
l
l
–
–
l
l
l
–
–
–
–
–
l
–
–
l
–
–
l
–
–
–
l
l
l
l
l
l
l
l
l
l
l
™
Escort Compatible
®
Downlook Option
SIA False Alarm
Prevention Features
–
–
–
Event Buffer
–
–
l
–
–
–
l
l
l
l
l
l
–
–
–
–
DEOL
–
–
l
–
–
–
l
l
l
l
l
–
DVACS
–
–
–
–
l
–
–
–
l
l
l
l
l
–
–
–
–
–
–
–
–
–
–
–
–
l
l
–
Access Control
(1) 4 or 6 digit codes
(2) PC5508, PC5516 or PC5532 LED keypad to match panel ordered
• 28 •
(3) DVACS is a trademark of Electro Arts Ltd.
International ISO 9001 Certification
Throughout our 20 year history, DSC Security Controls Ltd. has maintained the
highest standards of product quality in the industry. That is why we take
such pride in having received ISO 9001 certification for our main
engineering and manufacturing facilities - a rating that represents an
internationally recognized benchmark of quality. The ISO 9001 rating
assures you, our customer, of true product quality and it has been a key
factor in the successful introduction of DSC products worldwide.
Worldwide Agency Approvals
The products offered by the DSC Group of Companies are known and
trusted for their quality and reliability in markets around the world. That
trust is backed by product testing and approvals from safety and
rating agencies in every country we serve.