Download Viking Designer DDSB548D Installation guide
Transcript
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com UL F20605A EN C UL (070709J) Side-By-Side & Bottom-Mount Refrigerator/Freezer Table of Contents IMPORTANT–Please Read and Follow! Warnings & Important Information_____________________________________________________ 3 Professional & Professional Integrated Side-by-Side Dimensions & Specifications (Professional 42” & 48”) ________________________________ 6 Dimensions & Specifications (Professional Integrated 42” & 48”) _______________________8 Cutout Dimensions (42”) _________________________________________________________10 Anti-Tip Dimensions (42”) ________________________________________________________11 Cutout Dimensions (48”)_________________________________________________________ 12 Anti-Tip Dimensions (48”)________________________________________________________ 13 Professional & Professional Integrated Bottom-Mount Dimensions & Specifications (36”)_________________________________________________ 14 Cutout Dimensions (36”)_________________________________________________________ 16 Anti-Tip Dimensions (36”)________________________________________________________ 17 Cabinet Information (Professional) ____________________________________________________ 18 Cabinet Information (Professional Integrated) __________________________________________ 20 Designer Side-by-Side Dimensions & Specifications (42” & 48”)___________________________________________ 22 Cutout Dimensions (42”)_________________________________________________________ 24 Anti-Tip Dimensions (42”)________________________________________________________ 25 Cutout Dimensions (48”)_________________________________________________________ 26 Anti-Tip Dimensions (48”)________________________________________________________ 27 Designer Bottom-Mount Dimensions & Specifications (36”)_________________________________________________ 28 Cutout Dimensions (36”)_________________________________________________________ 30 Anti-Tip Dimensions (36”)________________________________________________________ 31 Cabinet Information (Designer)_______________________________________________________ 32 Custom Side Panel Dimensions (Professional) __________________________________________ 34 Custom Side Panel Dimensions (Designer & Professional Integrated) _____________________ 35 General Information ________________________________________________________________ 36 Unpacking & Moving _______________________________________________________________ 38 Installation_________________________________________________________________________ 39 Hinge Adjustment ______________________________________________________________ 40 Kickplate Installation ____________________________________________________________ 42 Door Stop Adjustment __________________________________________________________ 43 Water Filter Installation __________________________________________________________ 44 System Specifications and Data___________________________________________________ 45 Final Installation ________________________________________________________________ 46 Performance Checklist ______________________________________________________________ 47 Control Panels _____________________________________________________________________ 48 Service & Registration_______________________________________________________________ 49 • Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product. 2 Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. • To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated construction. This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others. All safety messages will be preceded by the safety alert symbol and the word“DANGER” or “WARNING.” These words mean: • The installer should leave these instructions with the consumer who should retain them for local inspector’s use and for future reference. D A N G E R You will be killed or seriously injured if you don’t follow instructions. WARNING You can be killed or seriously injured if you don’t follow instructions. All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. 3 IMPORTANT–Please Read and Follow! IMPORTANT–Please Read and Follow! A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances. • The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture. • Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below. It is your responsibility to: • comply with installation specifications and dimensions. • properly install unit. • remove any moldings or decorative panels that prevent the unit from being serviced. • make sure that you have these materials (not provided with your unit), which are necessary for proper installation: • 1/4” (6 mm) copper tubing with shutoff valve • 6– #8 x 3” (7.6 cm) wood screws (longer screws may be required) • 1– Saddle valve (do not use self-piercing feature of the valve) • assure that floor will support unit, door panels and contents (approximately 1200 pounds [540 kg]). • provide a properly grounded electrical outlet. • assure that location will permit appliance doors to open 90° minimum. If • • • • the use of a GFI is required, it should be: Of the receptacle type (breaker type or portable type NOT recommended) Used with permanent wiring only (temporary or portable wiring NOT recommended) On a dedicated circuit (no other receptacles, switches or loads in the circuit) Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended) • Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard) • In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations) • Protected from moisture (water, steam, high humidity) as much as reasonably possible WARNING WARNING ELECTRICAL SHOCK HAZARD TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions. Disconnect power or turn power disconnect switch to OFF position before removing top grille. Failure to do so can result in death or electrical shock. Use two or more people to move and install appliance. Failure to do so can result in death or serious injury. Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping. Use cardboard shipping material or plywood under unit until it is installed in the operating position to protect floor surface. 4 5 Dimensions Specifications (Professional Side-By-Side) (Professional Side-By-Side) 42” Professional Side-By-Side 42” Professional Description (104.1 (9.1 cm2” ) /2” 1–1cm) cm) (3.8 42” (106.7 cm) Cutout width Cutout height Cutout depth Electrical requirements 48” Professional 9–5 / (23.332” 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with cm) 47” (119.4 3–19/3 (9.1 cm2” ) 1– cm) cm) Requirements (3.8 48” (121.9 cm) 75–1 (192 5/16” .9 cm ) 9–5 / (23.332” 82 (21 –3/4” 0.2 min cm) . 84– to (21 1/16” 3.5 ma cm) x. ” 27–1/4 cm) (69.2 cm) (192 5/16” .9 cm ) Description 82 (21 –3/4” 0.2 min cm) . 84– to (21 1/16” 3.5 ma cm) x. ” 27–1/4 cm) (69.2 Overall width Overall height from bottom Overall depth from rear Cutout width Cutout height Cutout depth Electrical requirements 2 .7 52 ( Overall interior dimensions Refrigerator Freezer Total capacity Approximate shipping weight 15.0 cu. ft. (425 liters) 9.0 cu. ft. (255 liters) 24.0 cu. ft. (680 liters) 652 lbs. (293.4 kg) ” /16 –3 m) 226.4 c 5 ( 6” 1/1 –1 m) 24 2.7 c (6 Maximum amp usage Inlet water Requirements 4” –3/ ) 20 .7 cm (52 ” /16 –3 ) 226.4 cm (5 6” 1/1 –1 m) 24 .7 c Overall interior dimensions Refrigerator Freezer Total capacity Approximate shipping weight VCSB548 VCSB548D 48” (121.9 cm) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To front edge of side trim: 22-3/16” (56.4 cm) To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm) 47-1/2” (120.7 cm) min. to 47-3/4” (121.3 cm) max. 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. 24” (61.0 cm) min. 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product 9.9 amps 1/4” copper tubing inlet waterline; 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi 18.5 cu. ft. (524 liters) 8.9 cu. ft. (252 liters) 27.4 cu. ft. (776 liters) 715 lbs. (321.8 kg) (62 6 15.0 cu. ft. (425 liters) 8.6 cu. ft. (243 liters) 23.6 cu. ft. (668 liters) 676 lbs. (304.2 kg) 48” Professional Side-By-Side 75–1 /4” 0–3cm) grounded 3-prong plug attached to product 9.9 amps 1/4” copper tubing inlet waterline; 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi Maximum amp usage Inlet water ” 1/2 VCSB542D 42” (106.7 cm) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To front edge of side trim: 22-3/16” (56.4 cm) To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm) 41-1/2” (105.4 cm) min. to 41-3/4” (106 cm) max. 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. 24” (61.0 cm) min. Overall height from bottom Overall depth from rear 41” 3–19/3 VCSB542 Overall width 7 18.5 cu. ft. (524 liters) 8.6 cu. ft. (243 liters) 27.1 cu. ft. (767 liters) 735 lbs. (330.8 kg) Dimensions Specifications (Professional Side-By-Side) (Professional Side-By-Side) 42” Professional Integrated Side-By-Side Description 42” Professional Integrated VISB542 Overall width Overall height from bottom Overall depth from rear 41 (104.1” cm) 3–19/3 (9.1 cm2” ) /2” 1–1cm) (3.8 42” (106.7 cm) Cutout width Cutout height Cutout depth Electrical requirements 48” Professional Integrated 9–5 / (23.332” cm) 47 (119.4” cm) 3–19/3 2” (9.1 cm ) /2” 1–1cm) requirements (3.8 48” (121.9 Maximum amp usage Inlet water cm) 75–1 (192 5/16” .9 cm ) 9–5 / (23.332” 82 (21 –3/4” 0.2 min cm) . 84– to (21 1/16” 3.5 ma cm) x. ” 26–1/2 cm) (67.3 cm) Description (192 5/16” .9 cm ) Overall width 82– (21 3/4 0.2 ” min cm) . ma cm) x. (67.3 /8” –3 ) 23 .4 cm (59 ” 24 cm) (61 Overall height from bottom Overall depth from rear 84– to (21 1/16” 3.5 ” 26–1/2 cm) 4” –3/ ) 20 cm .7 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product 9.9 amps 1/4” copper tubing inlet waterline; 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi 15.0 cu. ft. (425 liters) 9.0 cu. ft. (255 liters) 24.0 cu. ft. (680 liters) 625 lbs. (293.4 kg) 15.0 cu. ft. (411 liters) 8.6 cu. ft. (244 liters) 23.6 cu. ft. (668 liters) 676 lbs. (304.2 kg) 48” Professional Integrated Side-By-Side 75–1 (52 Overall interior dimensions Refrigerator Freezer Total capacity Approximate shipping weight VISB542D 42” (106.7 cm) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To front edge of side trim: 23-3/8” (59.4 cm) To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm) 42” (106.7 cm) 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. 24” (61.0 cm) min. Cutout width Cutout height Cutout depth Electrical requirements Maximum amp usage Inlet water .0 requirements ” 3/4 ) – 20 .7 cm (52 ” 3/8m) – 23 c .4 (59 ” 24 cm) Overall interior dimensions Refrigerator Freezer Total capacity Approximate shipping weight VISB548 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product 9.9 amps 1/4” copper tubing inlet waterline; 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi 18.5 cu. ft. (524 liters) 8.9 cu. ft. (252 liters) 27.4 cu. ft. (776 liters) 715 lbs. (321.8 kg) .0 (61 8 VISB548D 48” (121.9 cm) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To front edge of side trim: 23-3/8” (59.4 cm) To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm) 48” (121.9 cm) 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. 24” (61.0 cm) min. 9 18.5 cu. ft. (507 liters) 8.6 cu. ft. (243 liters) 27.1 cu. ft. (767 liters) 735 lbs. (330.8 kg) Cutout Dimensions Anti-Tip Dimensions (Professional Side-By-Side) 42” Professional 42” Professional & Professional Integrated 24” ) cm (61.0 (Professional Side-By-Side) Professional Anti-Tip Location See An ti-Tip b oard in Electric Outlet Location stallati on 6” (15.2 9” (22.9 Two 2”x 4” Mounting Boards 3” (7.6 cm) x 3-1/2” (8.9 cm) cm) cm) 3” ) m (7.6 c 9” (22.9 cm) 35” (88.9 cm ) 3–1/ 82 (210 –7/8” .5 anti- cm) m 79 (201 –3/8” .6 to cm) m in tip open board . & ing h eigh t in. bo anti- ttom of tip b oard 84 (213 –1/16” .5 anti- cm) m t a op ip boa x. enin g rd heig & ht (8.9 c2” m) 80 (204 –1/2” .6 to bocm) max NOTE: If unit is installed deeper than 24” (61.0 cm),then shim behind the mounting board by the difference. . anti- ttom of tip b oard 73-3 (186.4/8” cm) Water Line Entry Area 42 Professional Integrated Anti-Tip Location ” Prof (106.7 essio cm) n mod al Integ els o rated nly 41– 7–5/ (105 41–1 .4 /2 (106 41– to cm) min” . .0 cm 3/4” Pro ) m fess (106 42” ax. modional I.7 cm) els o nteg nly rate d 5/8 (1.6 ” cm) (19.4 3” (7.6 8” One 2”x 4” Mounting Board 3” (7.6 cm) x 3-1/2” (8.9 cm) (105 1/2” .4 cm ) 6–3/ cm) (17.1 4” cm) 1.5” ) m (3.8 c cm) 5/8 (1.6 ” cm) 3 (9.2 –5/8” cm) 1 (27.30–3/4 c m) ” / cm)2” 3–1/ 1” ) cm (8.9 c2” m) (2.5 10–1 (26.7 35” (88.9 cm ) (1.6 5/8” cm) Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height. NOTE: Top of unit must be placed firmly under anti-tip board. p waO ter tiona line l flo ent or ry 10 NOTE: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting board by the difference. 11 Cutout Dimensions Anti-Tip Dimensions (Professional Side-By-Side) (Professional Side-By-Side) 48” Professional & Professional Integrated 48” Professional & Professional Integrated 24” (61.0 cm) See An ti-Tip b Professional Anti-Tip Location Electric Outlet Location oard in st allation 6” (15.2 9” (22.9 Two 2”x 4” Mounting Boards 3” (7.6 cm) x 3-1/2” (8.9 cm) cm) cm) 3” ) m 9” (22.9 (7.6 c cm) 41” (104.1 82 (210 –7/8” .5 anti- cm) m (201 84 (213 –1/16” .5 anti- cm) m tip b ax. 80 (204 –1/2” .6 cm )m to 79–3 / .6 c 8” ope ning oard & heig ht (8.9 c2” m) to bo m) min . anti- ttom of tip b oard in tip open board . & ing h eigh t ax. bo anti- ttom of tip b oard 73-3/ (186.4 cm) 3–1/ NOTE: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting board by the difference. 8” cm) Water Line Entry Area 48 (12 ” essio 1.9 cm) n mod al Integ els o rated nly Prof Professional Integrated Anti-Tip Location One 2”x 4” Mounting Board 3” (7.6 cm) x 3-1/2” (8.9 cm) 47– (120 1/2” 7–5 .7 cm (19.4/8” 6 ) – c 3 m 5/8 ) (1 /4” 7.1 c (1.6 ” m cm) ) 3” (7.6 cm) (120 47–1 .7 /2 (121 47– to cm) min” . .2 cm 3/4” Pro ) m fes (12 48 ax. modsional 1.9 cm” els o Integ ) nly rate d 41” 5/8 (1.6 ” cm) 3 (9.2 –5/8” cm) 1 (2 0– 7.3 3/4” cm) p waO ter tiona line l flo ent or ry 12 ” 1-1/2m) (3.8 c /2” cm) 3–1/ 1” ) cm (8.9 c2” m) (2.5 10–1 (26.7 (104.1 cm) (1.6 5/8” cm) Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height. NOTE: Top of unit must be placed firmly under anti-tip board. NOTE: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting board by the difference. 13 Dimensions Specifications (Professional Bottom-Mount) (Professional Bottom-Mount) 36” Professional Bottom-Mount 36” Professional Description 35” (88.9 cm ) 36” 3–19/3 Overall width /2” 1–1cm) Overall height from bottom Overall depth from rear (3.8 (91.5 cm (9.1 cm2” ) ) 36” Professional Integrated 9–5/3 Cutout wdth Cutout height Cutout depth Electrical requirements 2 (23.3 cm” ) /2” 35” 5 (13 2” (88.9 cm ) 36” 3–19/3 1–1cm) (3.8 (91.5 cm (9.1 cm2” ) ) Maximum amp usage Inlet water 2.1 c m) 9–5/3 2 (23.3 cm” ) 82–3 (210.2/4” cm min. ) to ” 27–1/4 cm) (69.2 84–1 /1 (213.5 6” cm max. ) 5 (132 2” .1 cm ) 23–1 (58.5/16” cm) 82–3 (210.2/4” cm min. ) to ” 26–1/2 cm) (67.3 84–1 /1 (213.5 6” cm max. ) 4” –3/ ) 20 .7 cm (52 ” /16 –3 ) 226.4 cm (5 6” 1/1 –1 m) 24 .7 c 23–1 (58.5/16” cm) requirements .4 (59 ” 24 cm) .0 (61 14 grounded 3-prong plug attached to product 9.9 amps 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi 15.2 cu. ft. (431 Liters) 5.1 cu. ft. (145 Liters) 20.3 cu. ft. (576 Liters) 565 lbs. (254.3 kg) 36” Professional Integrated Bottom-Mount Description VIBB536 Overall width 36” (91.5 cm) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To front edge of side trim: 23-3/8” (59.4 cm) To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm) 36” (91.4 cm) 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. 24” (61.0 cm) min. Overall height from bottom Overall depth from rear Maximum amp usage Inlet water 4” –3/ ) 20 .7 cm (52 /8” –3 ) 23 cm 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with Overall interior dimensions Refrigerator Freezer Total capacity Approximate shipping weight Cutout wdth Cutout height Cutout depth Electrical requirements (62 VCBB536 36” (91.5 cm) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To front edge of side trim: 22-3/16” (56.4 cm) To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm) 35-1/2” (90.2 cm) min. to 35-3/4” (90.8 cm) max. 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. 24” (61.0 cm) min. requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product 9.9 amps 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi Overall interior dimensions Refrigerator Freezer Total capacity Approximate shipping weight 15.2 cu. ft. (431 Liters) 5.1 cu. ft. (145 Liters) 20.3 cu. ft. (576 Liters) 565 lbs. (254.3 kg) 15 Cutout Dimensions Anti-Tip Dimensions (Professional Bottom-Mount) 36” Professional & Professional Integrated 36” Professional & Professional Integrated 24” ) cm (61.0 See An ti-Tip b oard in Professional Anti-Tip Location Electric Outlet Location stallati on (Professional Bottom-Mount) 6” (15.2 Two 2”x 4” Mounting Boards 3” (7.6 cm) x 3-1/2” (8.9 cm) cm) 9” (22.9 cm) 3” ) m 9” (22.9 cm) (7.6 c 79–3 .6 to bo cm) min . anti- ttom of tip b oard 82 (210 –7/8” .5 anti- cm) min tip . 80–1 (204 open board & ing h eigh t .6 c r g he d & ight 3–1/ (8.9 c2” m) /2” to bo m) max . anti- ttom of tip b oard 84 (213 –1/16” .5 anti- cm) m t a op ip boa x. enin 29–1/2 (74.9 cm” ) /8” (201 NOTE: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting boards by the difference. 73-3/ (186.4 8” cm) Water Line Entry Area Professional Integrated Anti-Tip Location 36 ” Prof (91.5 essio c na m) mod l Integr el on a ly ted 7–5/ 5/8 (1.6 ” cm) (90.235–1 cm /2 (90.8 35–3 to ) min”. / c m Pro ) ma4” fess (91 36” x. modional I.5 cm) el o nteg nly rate d 3” (7.6 One 2”x 4” Mounting Board 3” (7.6 cm) x 3-1/2” (8.9 cm) 35–1 (19.4 8” cm 6 ) (1 –3/4” 7.1 c m) (90.2 /2” cm) .5” 1 m) (3.8 c 5/8” 3 (9 –5/ .2 cm 8” ) (1.6 1 (27.30–3/4 cm) ” cm) 1 (26.70–1/2” cm) 3–1/ (8.9 c2” m) 1” ) cm (2.5 (1.6 5/8” cm) Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height. NOTE: Top of unit must be placed firmly under anti-tip board. p waO ter tiona line l flo ent or ry 16 29–1/2 (74.9 cm” ) cm) NOTE: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting boards by the difference. 17 Cabinet Information Cabinet Information (Professional) Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/2” (6.4 cm) from the cabinet face. The handle protrudes an additional 2-1/2” (6.4 cm) into the room. (Professional) Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/2” (6.4 cm) from the cabinet face. The handles protrude an additional 2-1/2” (6.4 cm) into the room. Top View Top View Wall Wall 1–13/16” (4.6 cm) Space if 24” standard cabinet depth is used 1–13/16” (4.6 cm) Space if 24” standard cabinet depth is used 24” (61.0 cm) Standard Cabinet Depth 3/4” (1.9 cm) Full End Panel 24” (61.0 cm) Standard Cabinet Depth 3/4” (1.9 cm) Full End Panel Partial Overlay Cabinet Door Countertop Overhang Door 2–1/2” Door (6.4 cm) Offset 2–1/2” Top View (6.4 cm) Offset Wall 1–13/16” 24” (4.6 cm) Space if 24” standard cabinet depth is used (61.0 cm) Standard Cabinet Depth 3/4” (1.9 cm) Full End Panel 5/16” (0.8 cm) Door 2–1/2” (6.4 cm) Offset 18 19 Cabinet Information (Professional Integrated) Professional Integrated models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2” (6.4 cm) into the room. Cabinet Information (Professional Integrated) Professional Integrated models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2” (6.4 cm) into the room. Top View Overlapping cabinet doors Top View Wall Wall 3/4” (1.9 cm) space if 24” (61.0 cm) standard cabinet depth is used 1” (2.5 cm) space if 25” (63.5 cm) cabinet depth is used 24-3/4” (62.9 cm) 25” (63.5 cm) Countertop Depth 3/4” (1.9 cm) Full End Panel 24” 3/4” (61.0 cm) Standard Cabinet Depth (1.9 cm) Full End Panel Cabinet Door Door Door Flush Flush Top View Top View Flush mount cabinet doors Wall Wall 1” (2.5 cm) space if 25” (63.5 cm) cabinet depth is used 1” (2.5 cm) space if 25” (63.5 cm) cabinet depth is used 25” (63.5 cm) Cabinet Depth 3/4” (1.9 cm) Full End Panel 25” (63.5 cm) 3/4” (1.9 cm) Full End Panel Cabinet Door Door Door Flush Flush 20 21 24” (61.0 cm) Standard Cabinet Depth Dimensions Specifications (Designer Side-By-Side) (Designer Side-By-Side) 42” Designer Side-By-Side Description Designer 42” Overall width 41 3–1/2 (8.9 cm” ) 42 (106.7” cm) (104.1” cm) Overall height from bottom Overall depth from rear /2” 1–1 ) (3.8 cm Cutout width Cutout height Cutout depth Electrical requirements Designer 48” 9–5 / (23.332” cm) 47 3–1/2 (8.9 cm” ) 48 (121.9” cm) (119.4” cm) Maximum amp usage Inlet water /2” 1–1 ) (3.8 cm Requirements 75–1 (192 5/16 .9 cm ” ) 9–5 82– / (23.332” (21 3/4” 0.2 min cm) . 84– to (21 1/16” 3.5 ma cm) x. /2” 26-1 cm) (67.3 cm) (192 5/16” .9 cm ) Description 82 (21 –3/4” 0.2 min cm) . 84– to (21 1/16” 3.5 ma cm) x. /2” 26-1 cm) (67.3 Overall width Overall height from bottom Overall depth from rear Cutout width Cutout height Cutout depth Electrical requirements (59 ” 24 cm) .0 (61 Maximum amp usage Inlet water 4” –3/ ) 20 .7 cm (52 /8” –3 ) 23 .4 cm (59 ” 24 cm) .0 (61 22 DDSB542D 42” (106.7 cm) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To front edge of side trim: 23-3/8” (59.4 cm) To front of top gr:ille: 24” (61.0 cm) To front of handle: 26-1/2” (67.3 cm) 42” (106.7 cm) 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. 24” (61.0 cm) min. 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product 9.9 amps 1/4” copper tubing inlet waterline; 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi 15.0 cu. ft. (425 liters) 9.0 cu. ft. (255 liters) 24.0 cu. ft. (680 liters) 642 lbs. (289 kg) 15.0 cu. ft. (425 liters) 8.6 cu. ft. (243 liters) 23.6 cu. ft. (668 liters) 665 lbs. (299.3 kg) 48” Designer Side-By-Side 75–1 4” –3/ ) 20 .7 cm (52 /8” –3 ) 23 .4 cm Overall interior dimensions Refrigerator Freezer Total capacity Approximate shipping weight DDSB542 Requirements Overall interior dimensions Refrigerator Freezer Total capacity Approximate shipping weight DDSB548 DDSB548D 48” (121.9 cm) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To front edge of side trim: 23-3/8” (59.4 cm) To front of top grille: 24” (61.0 cm) To front of handle: 26-1/2” (67.3 cm) 48” (121.9 cm) 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. 24” (61.0 cm) min. 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product 9.9 amps 1/4” copper tubing inlet waterline; 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi 18.5 cu. ft. (524 liters) 8.9 cu. ft. (252 liters) 27.4 cu. ft. (776 liters) 705 lbs. (317.3 kg) 23 18.5 cu. ft. (524 liters) 8.6 cu. ft. (243 liters) 27.1 cu. ft. (767 liters) 730 lbs. (328.5 kg) Cutout Dimensions (Designer Side-By-Side) 24” ) .0 cm (61 Anti-Tip Dimensions (Designer Side-By-Side) 42” Designer 42” Designer See An ti-T Electric Outlet Location ip boa rd inst allation 6” (15.2 9” (22.9 cm) Anti-Tip Location cm) 9” (22.9 cm) 79 (201 –3/8” .6 to bo cm) min . 82 (210 –7/8” .5 anti- cm) min tip . (3.8 c 35” (88.9 cm 80–1 (204 84 .6 (213 –1/16” .5 anti- cm) m tip b ax. ) /2” to bo cm) max . anti- ttom of tip b oard ope ning oard & heig ht 2” 1–1/ m) anti- ttom of tip b oard open board & ing h eigh t 3–1/ (8.9 2” cm) 73–3/ (186.4 8” cm) Water Line Entry Area 7–5/ 5/8 (1.6 ” cm) (106 42” .7 cm ) 42 (106 ” .7 cm ) (19.4 8” 6 –3 cm) (17.1/4” cm) 3” (7.6 cm) One 2”x 4” Mounting Board 1–1/2” (3.8 cm) x 3–1/2” (8.9 cm) NOTE: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting board by the difference. 5/8 (1.6 ” cm) 3 (9.2 –5/8” cm) 1 (2 0– 7.3 3/4” cm) (26.7 /2” cm) 1” ) cm Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height. NOTE: Top of unit must be placed firmly under anti-tip board. (2.5 10–1 (1.6 5/8” cm) p waO ter tiona line l flo ent or ry 24 25 Cutout Dimensions (Designer Side-By-Side) Anti-Tip Dimensions (Designer Side-By-Side) 48” Designer 48” Designer 24” ) cm (61.0 See An ti-Tip b Electric Outlet Location oard in st allation 6” (15.2 9” (22.9 Anti-Tip Location cm) cm) 9” (22.9 cm) 79 (201 –3/8” .6 to bo cm) min . 82–7 (210 .5 /8” ning oard & heig ht (3.8 c 41” (104.1 cm) 80 (204 –1/2” .6 to bo cm) max 84 (213 –1/16” .5 anti- cm) m tip b ax. ope 2” 1–1/ m) anti- ttom of tip b oard anti- cm) min tip open board . & ing h eigh t . anti- ttom of tip b oard 3–1/ (8.9 2” cm) 73–3 (186.4/8” cm) Water Line Entry Area 47– 7–5/ 5/8 (1.6 ” cm) (121 48” .9 cm ) (120 1/2” .7 cm ) (19.4 8” 6 –3 cm) (17.1/4” cm) 3” (7.6 cm) One 2”x 4” Mounting Board 1–1/2” (3.8 cm) x 3 1/2” (8.9 cm) NOTE: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting board by the difference. 5/8 (1.6 ” cm) 3 (9.2 –5/8” cm) 1 (2 0– 7.3 3/4” cm) NOTE: Top of unit must be placed firmly under anti-tip board. (2.5 1 (26.70–1/2” cm) Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height. 1” ) cm (1.6 5/8” cm) p waO ter tiona line l flo ent or ry 26 27 Dimensions Specifications (Designer Bottom-Mount) 36” Designer Bottom-Mount Designer 36” Description Overall width 35” (88.9 c m) 36” /2” 1–1cm) (3.8 Overall height from bottom Overall depth from rear (91.5 c 3–1/2 m) (8.9 cm” ) (Designer Bottom-Mount) 9–5/3 2 (23.3 c ” m) Cutout width Cutout height Cutout depth Electrical requirements Maximum amp usage Inlet water Requirements DDBB536 36” (91.5 cm) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To front edge of side trim: 23-3/8” (59.4 cm) To front of top grille: 24” (61.0 cm) To front of handle: 26-1/2” (67.3 cm) 36” (91.5 cm) 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. 24” (61.0 cm) min. 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product 9.9 amps 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi Overall interior dimensions Refrigerator Freezer Total capacity Approximate shipping weight 5 (132 2” .1 cm ) 15.2 cu. ft. (431 Liters) 5.1 cu. ft. (145 Liters) 20.3 cu. ft. (576 Liters) 565 lbs. (254.3 kg) 82–7 (210.5/8” cm min. ) to /2” 26-1 cm) (67.3 84–1 / (213.5 16” cm max. ) 23–1 (58.5/16” cm) /4” –3 ) 20 .7 cm (52 /8” –3 ) 23 4 cm . (59 ” 24 cm) .0 (61 28 29 Cutout Dimensions (Designer Bottom-Mount) Anti-Tip Dimensions (Designer Bottom-Mount) 36” Designer 24” (61.0 cm) See An ti-Tip b oard in 36” Designer Electric Outlet Location stallati on 6” (15.2 cm) Anti-Tip Location 9” (22.9 cm) 79 (201 –3/8” .6 to bo cm) min . 82 (210 –7/8” .5 anti- cm) min tip . open board & ing h eigh t 80 (204 –1/2” .6 to b cm) ma 84 (213 –1/16” .5 anti- cm) m tip b ax. ope ning oard & heig ht 2” 1–1/ m) (3.8 c anti- ttom of tip b oard x. o anti- ttom of tip b oard 29” (73.7 cm ) 3–1/ (8.9 c2” m) 73–3 (186.4/8” cm) Water Line Entry Area 36 7–5/ 5/8 (1.6 ” cm) (91.5 36” cm) (91.5 ” cm) (19.4 8” 6 –3 cm) (17.1/4” cm) 3” (7.6 cm) One 2”x 4” Mounting Board 1–1/2” (3.8 cm) x 3–1/2” (8.9 cm) NOTE: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting board by the difference. 5/8 (1.6 ” cm) 3 (9.2 –5/8” cm) 1 (2 0– 7.3 3/4” cm) (26.7 / cm)2” 1” ) cm (2.5 10–1 Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height. NOTE: Top of unit must be placed firmly under anti-tip board. (1.6 5/8” cm) p waO ter tiona line l flo ent or ry 30 31 Cabinet Information Cabinet Information (Designer) Designer models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except 2-1/2” (6.3 cm) handle depth. Top View (Designer) Designer models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except 2-1/2” (6.3 cm) handle depth. Overlapping cabinet doors Top View Wall 3/4” Wall (1.9 cm) space if 24” (61.0 cm) standard cabinet depth is used 1” (2.5 cm) space if 25” (63.5 cm) cabinet depth is used 24-3/4” (62.9 cm) 3/4” (1.9 cm) Full End Panel 24” (61.0 cm) Standard Cabinet Depth 3/4” (1.9 cm) Full End Panel Cabinet Door Door Door Flush Flush Top View Top View Flush mount cabinet doors Wall Wall 1” 1” (2.5 cm) space if 25” (63.5 cm) cabinet depth is used (2.5 cm) space if 25” (63.5 cm) cabinet depth is used 25” (63.5 cm) Cabinet Depth 3/4” (1.9 cm) Full End Panel 25” (63.5 cm) 3/4” (1.9 cm) Full End Panel Cabinet Door Door Door Flush 32 25” (63.5 cm) Countertop Depth Flush 33 24” (61.0 cm) Standard Cabinet Depth Custom Side Panel Dimensions (Professional) 3/16” (0.5 cm) Back filler panel ” 16 -7/ m) 227.0 c Custom Side Panel Dimensions (Designer & Professional Integrated) 3/4” (1.9 cm) End panel Z-Bracket /4” 1/4” 3/4” (0.6 cm) (1.9 cm) End panel -3 ) 21.2 cm 6”cm) .2 (15 1” (2.5 cm) (55 (5 5/32” (0.4 cm) 4” -3/ ) 21.2 cm ” 16 -7/ m) 227.0 c (55 (5 (2182-7 0.5 /8 cm ” )m in. (21 84-1to 3.5 /1 cm 6” )m ax .* (2182-7 0.5 /8 cm ” )m in. (21 84-1to 3.5 /1 cm 6” )m ax .* 6”cm) .2 (15 8 (21 2-7 0.5 /8 cm ” )m in. (21 84-1to 3.5 /1 cm 6” )m ax .* (2182-7 0.5 /8 cm ” )m in. (21 84-1to 3.5 /1 cm 6” )m ax .* ” 24 cm) 4” -1/ ) 22.0 cm .0 (61 (61 /4” 2-1 m) Optional kickplate Notch, dimensions determined by cabinets 2 .0 c (61 * Depending on how high leveling feet are raised, and cabinet enclosure height. 34 Optional kickplate ” 2 4 cm ) Notch, dimensions determined by cabinets .0 (61 * Depending on how high leveling feet are raised, and cabinet enclosure height. 35 General Information General Information this appliance be provided. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, grounding-type wall receptacle. Do not use an extension cord. Area Requirements Verify the following: • Unit can fit into residence and can be moved around corners and through doorways. • Floors can support unit’s weight plus food weight (approximately 1200 pounds [540 kg] total). If codes permit a separate grounding wire to be used, it is recommended that a qualified electrician determine that the grounding path is adequate. • Rear wall is solid and is able to support two horizontally mounted 2X4s (included) bolted to two wall studs. The 2X4 board bolt heads must be flush with 2X4 to prevent obstruction. • Remove anything attached to rear or side walls that can obstruct unit installation. DO NOT ground to a gas pipe. Check with a qualified electrician if you are not sure the appliance is properly grounded. DO NOT have a fuse in the neutral or grounding circuit. • Cutout dimensions are accurate. Anti-Tip Requirements • Electrical outlet is in correct location. The anti-tip boards should be fastened into position prior to moving the unit into the opening. • Water line is in correct location. • Do not install a refrigeration unit near a heat source, nor in a location where the surrounding temperature will fall below 60º F (16º C). NOTE: Additional mounting boards may be required if the unit does not touch the back wall of the enclosure. To prevent unit from tipping forward, it must be secured in place with a solid soffit or wood block. Electrical Requirements It is the customer’s responsibility to: • Contact a qualified electrical installer. • Assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70latest edition or Canadian Electrical Code C22.1-1998 and C22.2 No. 0-M91 (or latest edition), and all local codes and ordinances. A 115 volt, 60-Hz, 15 amp, fused, electrical supply is required. It is required that a separate circuit serving only WARNING To avoid serious illness or death, do not use unit where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. The contaminants or other substances removed or reduced by this water treatment system are not necessarily in you water. 36 • Do not use plastic water lines from the household plumbing to the water inlet valve connection on the refrigeration unit. Water Supply Requirements CAUTION Be sure to have a replacement cartridge available when filter change is required. •If water filtration system has been allowed to freeze, replace filter cartridge. •If system has not been used in several months, and water has an unpleasant taste or odor, flush system by dispensing 2-3 glasses of water. If unpleasant taste or odor persists, change filter cartridge. • Do not use the self-piercing feature of a saddle valve. The hole made by the piercing lance is too small for the water flow rate required by the ice maker. • If saddle valve is not used, place a separate shut-off valve in an easily accessible location between water supply and the unit. Do not locate shut-off valve behind the unit. Use only 1/4” (6 mm) copper tubing for water line. Do Not install copper tubing in area where temperatures drop below 35˚ F (1.7˚ C). Before attaching copper tubing to the unit, flush at least 2 quarts (1.9 L) of water through the copper tubing and into a bucket to remove any particles in the water line. • The installation of Viking units with a reverse osmosis system is acceptable as long as the water pressure remains within the allowable PSI as stated below. It is important to note that with many reverse osmosis systems, the pressure starts off high, but then it decreases as the water level of the reverse osmosis storage area drops. This must be considered when checking the water pressure coming into the unit. • Viking Range Corporation is not responsible for property damage due to improper installation or water connection. • Connect 1/4” (6 mm) flexible copper tubing to household plumbing in compliance with local codes and ordinances. • Connect a vertical or horizontal 1/2” (1.2 cm) to 1-1/4” (3.2 cm) COLD water line near water area. • Length of copper tubing must reach from water supply connection to the unit connection with an additional length to facilitate moving the unit out of enclosure for cleaning or service. Tubing should be soft instead of rigid and ends should be free of burrs. • Run water line through the floor, back, or side wall. Tubing should lay flat on floor underneath the unit. Clamp tubing to wall or floor. • Water pressure must be greater than 20 psi and less than 120 psi on non-dispensers and greater than 35 psi and less than 120 psi on dispensers. • Copper tubing route must be above 35˚ F (1.7˚ C) to prevent water line from freezing. 37 Installation General Information 2a 1 TIP OVER HAZARD • Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping. Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions. Use two or more people to move and install appliance. Failure to do so can result in death or serious injury. • Do not remove protective film until unit is in operating position. • All four leveling legs must contact the floor to support and stabilize the full weight. • Do not drop unit. • Remove exterior shipping materials prior to moving unit into home, except door latching device. Unpacking Unit • Use two or more people to move and install unit. Failure to follow this instruction can result in back or other injury. 3. Cut carton rear approximately 1/4” (0.6 cm) to 1” (2.5 cm) from right corner with a utility knife extended 1/4” (0.6 cm). • To avoid personal injury, wear gloves when performing any installation procedure and wear eye protection when cutting metal straps. 4. Remove carton and exterior packaging. Save cardboard shipping material to protect floor surface when installing unit. Remove anti-tip board, kickplate and door trim pieces (DF models) from rear of unit. 1. Remove top and bottom strap. 2. Remove top cap. Place unit in front of cutout. (Professional) Lift center grille louver up and pull out. 3 2b Moving Unit (Designer) Pull the center grille louver up at an angle and pull out. Using an 8” magnetic nut driver, remove the two 1/4” screws. 4 Slip appliance dolly between unit and skid. Remove unit from skid. NOTE: Use excess packaging to protect decorative trim; also, verify that leveling legs are up (0” adjustment). Remove shipping brackets from skid by removing four bolts (two on each side) with a 1/2” deep-well socket wench and a pair of pliers. NOTE: Tilting unit is not required to remove shipping brackets. 38 Remove grille assembly. 39 Hinge Adjustment 6 5 Front of unit 10a 9 2 2 3” 1 1 Remove four side screws and remove unit top. 3 Plug in power cord to verify operation. NOTE: Make sure power switch is in the “On” Position. Loosen the four hinge screws. Adjust door. Retighten four hinge screws. 7 Place unit within 3” of being flush with cabinets. NOTE: To avoid cabinet damage, place cardboard between cabinets and unit. When moving unit, do not crimp, kink or crush water supply line. 10b 11 1 2 Replace unit top. Replace four side screws. Carefully move unit until semi flush with cabinet (depending on unit). 8a 12 8b Wall Wall 2x4 2x4 Refrigerator Pull supply tubing forward under unit. NOTE: DO NOT use plastic water lines. 13 Refrigerator Attach one 2x4 to wall stud (refer to dimensions page for exact location). If needed, depending on cabinet and depth, attach second 2x4 to first 2x4. 40 Flush water line by running two quarts of water into a bucket. Turn water off. Connect supply tube to water valve using a 1/2” wrench. NOTE: DO NOT overtighten. 41 Door Stop Adjustment 14 (Side-by-Side) 20 15 21 1 1 90˚ 110˚ 120˚ 3 2 2 Turn on water supply and check for leaks. Lift unit off rollers to desired height and level unit using a 5/16” head wrench. NOTE: DO NOT use an electric device. Overtightening can cause damage. 16 17 Open refrigerator door so door stop and shoulder screw are accessible. NOTE: Shoulder screw should be in 110˚ door opening position. Door Stop Adjustment Remove shoulder screw and place in 90° or 120° position. (Bottom-Mount) 22 Screw 23 120˚ 110˚ Wall 90˚ 2x4 1 3 Refrigerator 2 Attach positive secure self-tapping bolts to 2x4 using a 22” extension. Verify that drain pan is installed and aligned. Kickplate Installation Open refrigerator door so door stop and shoulder screw are accessible. NOTE: Shoulder screw should be in 110˚ door opening position. 19 18 1 2 1 1 2 3 2 Align holes on both ends of louvered panels and insert screws. Using a Phillips screwdriver, attach the kickplate to the unit and adjust to desired height. 42 43 Remove shoulder screw and place in 90˚ or 120˚ position. Water Filter Installation (Side-by-Side with Dispenser) Water Filter System Specification and Performance Data Sheet 25 24 This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration of less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.* (100% safety factors builtin for unmetered usage for health claims only.) 2 Parameter 1 Locate water filter door. The door is located under the Adjustable Cold Zone™ handle. Chlorine T&O Particulates** Push upper left corner of door to release latch and pull door downward. Parameter 26 27 1 Turbidity Cysts 3 USEPA McL Asbestos Influent Average 1.88 mg/L 5,700,000 #/mL Standard No. 42: Aesthetic Effects Influent Effluent Challenge Average Maximum Concentrations 2.0 mg/L + 10% <0.05mg/L 0.06 mg/L at least 29.83#/mL 10,000 particles/mL 140 #/mL %Reduction Average Minimum Min. Req. Reduction >97.26% 96.84% > 50% 99.98% 99.91% > 85% Standard No. 53: Health Effects Influent Effluent Challenge Average Maximum Concentrations 1 NTU*** 10.73 NTU*** 11 + 1 NTU 0.36 NTU .049 NTU 99.95% Reduction 200,000 #/L min. 50,000/L <1 <1 99% Reduction 155 MF/L 107 & 108 fibers/L <1 <1 USEPA McL Influent Average %Reduction Average Minimum Min. Req. Reduction 97.09% 95.20% >99.99% >99.99% 0.5 NTU >99.95% >99.99% >99.99% 99% fibers>10micrometers 0.015 mg/L 0.015 mg/L Mercury at pH 6.5 0.002 mg/L Mercury at pH 8.5 0.002mg/L Lindane 0.0002 mg/L Atrazine 0.003 mg/L Toxaphene 0.003 mg/L Lead at pH 6.5 Lead at pH 8.5 2 Insert filter cartridge into circular opening in filter housing. Rotate clockwise gently until filter stops. Close water filter door. NOTE: Allow 1-2 minute delay in water dispersal to allow internal water tank to fill. Flush air from the system by running water through the dispenser continuously for 3 minutes. 0.153 mg/L 0.150 mg/L 0.006 mg/L 0.006 mg/L 0.002 mg/L 0.00873 mg/L 0.015 mg/L 0.15mg/L 0.15mg/L .006mg/L .006mg/L .002mg/L .009mg/L .015mg/L + + + + + + + 10% <.001 10% <.001 -10% 0.00026 -10% 0.0008 10% 0.000025 10% <.002 mg/L 10% <0.001 <.001 <.001 0.0005 0.0015 0.00007 <.002 mg/L <0.001 >99.35% >99.35% 98.72% 98.72% 98.72% 76.99% 92.97% >99.35% 97.35% 90.91% 75.93% 96.50% 75.31% 91.67% 0.010 mg/L 0.010 mg/L 0.002mg/L 0.002mg/L 0.0002mg/L 0.003 mg/L 0.003mg/L *Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 + 0.5; temp of 68o + 5oF (20o + 3oC) **Measurement in particles/mL. Particles used were 0.5 - 1 microns ***NTU = Nephelometric Turbidity units Operating Specifications Capacity: Certified for up to 750 gallons (2,838 L); up to nine months Pressure Requirement: 20 - 120 psi (2.8 - 8.2 bar) Temperature: 33-100oF (0.6 - 38oC) Flow rate: 0.78 gpm (2.9 l/min.) Check for compliance with the state and local laws and regulations. Note: While the testing was performed under standard laboratory conditions, actual performance may vary. Must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines. Installation instructions, parts and service availability, and standard warranty are included with the product when shipped. This drinking water system must be maintained according to manufacturer’s instruction, including replacement of filter cartridges. System tested and certified by NSF International against Standard 42 for the reduction of chlorine taste Manufactured by: Cuno, a 3M company and odor, particulate Class I and Standard 53 for the 1000 Apollo Road reduction of Lead, Lindane, Atrazine, Mercury, Eagan, MN 55121 Toxaphene, Cyst, Turbidity, and Abestos. (651) 450-4913 44 45 Final Installation 28 29 Replace top air grille. Performance Checklist Using an 8” magnetic nut driver, replace the two 1/4” screws. 30a 30b (Professional) Replace the center grille louver. (Designer) Replace the center grille louver. 31 32 h Verify cabinet size. h Align/square door(s). h Verify electrical supply and water supply (if applicable). h Verify drain pan is properly installed and no leaks on water connection. h Install anti-tip device(s) and verify unit is secure. h Install kickplate. h Position unit in cutout, level at desired height and secure unit. h Plug-in unit and verify operation. Open door. Display should flash. Press “ACTIVATE CONTROLS” pad and close door. NOTE: There is a 6 minute delay before the unit starts. 46 h Connect water supply (if applicable). • Verify icemaker fill tube is properly inserted. • Verify icemaker bail arm is down. • Verify dispenser operation (if applicable). h Remove internal packaging and labels and wipe unit down. Installer’s information: Installer’s name:_____________________________ Installer’s company:_________________________ Date: ________________________________________ 47 Verify Operations Service & Registration Control Panels Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician. Bottom Mount Side by Side Record the following information indicated below. You will need it if service is ever required. The serial number and model number for your appliance are located on the identification plate mounted behind the top light. 1. Press “Activate Controls” pad. 2. Verify unit is not in Sabbath Mode. If in Sabbath Mode: A. The Sabbath Mode will disable the interior lights, display (except three blue squares) and alarm. (See picture below for visual indication of Sabbath Mode.) Model number _________________________________________ Serial number _________________________________________ Date of purchase To exit the Sabbath Mode: B. Press and hold “Activate Controls” and then “Display Off” for 3 seconds. (The control will beep three times to alert the user the Sabbath Mode has been exited.) 3. Verify unit is not in Showroom Mode. If in Showroom Mode: A. The Showroom Mode will disable the refrigerator system but all other functions are normal. These include lights and control. (See picture below for visual indication of Showroom Mode.) _________________________________________ Date installed _________________________________________ Dealer's name _________________________________________ Address To exit Showroom Mode: B. Press and hold “Activate Controls”; while holding, press and hold “Higher” and “Alarm Off” together. (The control will beep three times to alert the user that Showroom Mode has been exited.) 4. Press “Alarm Off” and “Display Off” at the same time and hold until beeps (force start compressor). 5. All models need to be set at the 5th bar for Refrigerator and Freezer - factory setting. 48 _________________________________________ 49 50 51