Download Venstar T1045 Owner`s manual

Transcript
residential
THERMOSTAT
Digital
Thermostat
T1045
5+2 DAY
PROGRAMMABLE
up to
2-heat
& 1-cool
HEAT
PUMP
Stages: 2-Heat, 1-Cool
Battery or System Powered
Auxiliary Heat Indicator
Back-Lit Digital Display
Fahrenheit or Celsius
Service Filter Indicator
Bi-Color LED (when system powered)
Use with most 1 or 2 Stage Heat Pump Heat and 1 stage Heat Pump Cool units
INSTALLATION
INSTRUCTIONS
Venstar Inc. 05/08
INSTALLATION INSTRUCTIONS
Contents
T1045
Page #
Safety Warnings
Preparation
Remove Old Thermostat
Battery Replacement
Wire Connections
Test Operation
Troubleshooting
Warranty
Page 2
INSTALLATION INSTRUCTIONS
T1045
Safety Warnings
P/N T1045
CAUTION
Follow Installation Instructions carefully.
DISCONNECT POWER TO THE HEATER AIR CONDITIONER BEFORE REMOVING
THE OLD THERMOSTAT AND INSTALLING
THE NEW THERMOSTAT.
WARNING
CAUTION
The two Alkaline “AA” batteries must be replaced at
least once every 12 months to ensure proper
operation. The Low Battery icon (fig. 1) will
appear on the display when it is time to replace
the batteries. If the thermostat is connected to FIG. 1
24v power, the batteries should still be installed, but
are not required.
When
is displayed the batteries must be replaced
immediately. The manufacturer cannot be liable for
improper operation of the thermostat if the batteries are
not immediately replaced.
Annual battery replacement is especially critical in
locations subject to freezing temperatures. The
thermostat will be unable to turn on the heating system
if the batteries are exhausted.
Page 3
INSTALLATION INSTRUCTIONS
T1045
Preparation
:
I2:00
PM
Su
:
I2:00
PM
Su
Proper installation of the thermostat will be
accomplished by following these step
by step instructions. If you are unsure
about any of these steps, call a qualified
technician for assistance.
These tools will be required:
Flat Blade
Screwdriver
:
I2:00
PM
Su
:
I2:00
PM
Su
:
I2:00
Su
PM
Wire cutter
& Stripper
Make sure your Heater/Air Conditioner
is working properly before beginning
installation of the thermostat.
Carefully unpack the thermostat.
Save the screws and instructions.
Turn off the power to the Heating/Air
Conditioning system at the main fuse
panel. Most residential systems have
a separate breaker for disconnecting
power to the furnace.
Page 4
INSTALLATION INSTRUCTIONS
T1045
Remove & Replace
Old Thermostat
:
I2:00
PM
Su
:
I2:00
PM
Su
:
I2:00
PM
Su
:
I2:00
Su
PM
Remove the cover of the old thermostat.
If it does not come off easily check for
screws.
Loosen the screws holding the thermostat
base or subbase to the wall, and lift away.
Disconnect the wires from the old
thermostat. Tape the ends of the wires
as you disconnect them, and mark them
with the letter of the terminal for easy
reconnection to the new thermostat.
Keep the old thermostat for reference
purposes, until your new thermostat is
functioning properly.
Page 5
INSTALLATION INSTRUCTIONS
T1045
Battery Replacement
The batteries are easily accessible from the battery
slot located on the front of the thermostat (fig. 1). To
open the battery slot, press down on the battery
cover (fig. 1) and pull out (fig. 2).
Pull out
:
I2:00
PM
Su
Press
down
Battery
slot
(Bottom View)
FIG. 1
FIG. 2
Remove the old batteries and replace with the new
AA alkaline batteries (fig. 3).
New
batteries
in
Old
batteries
out
Place the bottom hook of the battery cover into the
Snap closed
slot and snap closed (fig. 4).
The batteries must be replaced
immediately when the thermostat
displays the low battery icon (fig.
1). If the thermostat is connected
(Bottom View)
to 24v power, the batteries should
still be installed. Installing the batteries when
system powered (24VAC) will keep the clock
running in the event of line power interruption.
Page 6
Bottom
Hook
FIG. 4
FIG. 1
INSTALLATION INSTRUCTIONS
T1045
Wire Connections
:
I2:00
Su
PM
If the terminal designations on your old
thermostat do not match those on the
new thermostat, refer to the chart below
or the wiring diagrams that follow.
Wire from the
old thermostat
terminal marked
Function
Install on the
new thermostat
connector marked
C (optional)
C
Common
Rc, R, M, Vr, A
Power
R
Y1 or Y
Cooling
Y
W1, W or H
Auxiliary Heat
W
G or F
Fan
G
Rev. Valve
B
B
(Energize to Heat)
O
Rev. Valve
(Energize to Cool)
Page 7
O
INSTALLATION INSTRUCTIONS
T1045
Sample Wiring Diagrams
4 Wire, 1 Stage Cooling, 1 Stage Heat-Heat Pump with O reversing valve.
Residential Heat Pumps, split systems & package units, with no auxiliary heat.
Common wire optional*
O B GW Y R C
FAN
G
REVERSING VALVE
O
COMPRESSOR
Y
POWER
R
4 Conductor 18 to 22 gauge
unshielded cable from the
thermostat to the equipment.
* Common wire is optional in all installations. If a common wire is not
used the thermostat must be powered by two AA alkaline batteries.
These batteries must be replaced (page 6) each year or when the Low
Battery indicator is displayed (page 3).
Page 8
INSTALLATION INSTRUCTIONS
T1045
Sample Wiring Diagrams
5 Wire, 1 Stage Cooling, 2 Stage Heat-Heat Pump with O reversing valve.
Residential Heat Pumps, split systems & package units, with auxiliary heat.
Common wire optional*
O B GW Y R C
FAN
G
REVERSING VALVE
O
AUXILIARY HEAT
Y
COMPRESSOR
W
POWER
R
5 Conductor 18 to 22 gauge
unshielded cable from the
thermostat to the equipment.
* Common wire is optional in all installations. If a common wire is not
used the thermostat must be powered by two AA alkaline batteries.
These batteries must be replaced (page 6) each year or when the Low
Battery indicator is displayed (page 3).
Page 9
INSTALLATION INSTRUCTIONS
T1045
Sample Wiring Diagrams
4 Wire, 1 Stage Cooling, 1 Stage Heat-Heat Pump with B reversing valve.
Residential Heat Pumps, split systems & package units, with no auxiliary heat.
Common wire optional*
O B GW Y R C
FAN
G
REVERSING VALVE
B
COMPRESSOR
Y
POWER
R
4 Conductor 18 to 22 gauge
unshielded cable from the
thermostat to the equipment.
* Common wire is optional in all installations. If a common wire is not
used the thermostat must be powered by two AA alkaline batteries.
These batteries must be replaced (page 6) each year or when the Low
Battery indicator is displayed (page 3).
Page 10
INSTALLATION INSTRUCTIONS
T1045
Sample Wiring Diagrams
5 Wire, 1 Stage Cooling, 2 Stage Heat-Heat Pump with B reversing valve.
Residential Heat Pumps, split systems & package units, with auxiliary heat.
Common wire optional*
O B GW Y R C
FAN
G
REVERSING VALVE
B
AUXILIARY HEAT
Y
COMPRESSOR
W
POWER
R
5 Conductor 18 to 22 gauge
unshielded cable from the
thermostat to the equipment.
* Common wire is optional in all installations. If a common wire is not
used the thermostat must be powered by two AA alkaline batteries.
These batteries must be replaced (page 6) each year or when the Low
Battery indicator is displayed (page 3).
Page 11
INSTALLATION INSTRUCTIONS
T1045
Test Operation
:
I2:00
PM
Su
:
I2:00
PM
Su
Turn on the power to the Heat Pump.
On the thermostat, slide the Mode Switch
to HEAT. Press the COOLER or WARMER
button until the set temperature is 10 degrees
above room temperature. The HVAC unit
should energize in the heating mode.
Note: You may need to wait up to five minutes
for heating to energize due to the compressor
lockout feature. There is a two minute minimum run-time for first stage heating.
On the thermostat, slide the Aux Heat
Switch to the NORMAL position. The
Aux Heat icon will appear indicating that
the thermostat has energized Aux Heat
(page 7 of the Owner’s Manual).
:
I2:00
Su
PM
TWO STAGE OPERATION - The 2nd stage
of heat (auxiliary heat) is turned on when
the room temperature is equal to or less
than: the setpoint minus the 1st stage
deadband (one degree, adjustable), minus
the 2nd stage deadband (two degrees,
non-adjustable).
Cooling
Heating
2nd Stage
turn on
Deadband
Deadband
Deadband
db 2
(non-adj. 2 )
db 1
(adj. 1-6 )
db 1
(adj. 1-6 )
1st Stage
turn on
Page 12
Heat or Cool
Setpoint
1st Stage
turn on
INSTALLATION INSTRUCTIONS
T1045
Test Operation
:
I2:00
PM
Su
On the thermostat, slide the Mode Switch
to COOL. Press the COOLER or WARMER
buttons until the set temperature is 10
degrees below room temperature. The
HVAC unit should energize in the cooling
mode (Page 6 of the Owner’s Manual).
Note: You may need to wait up to five minutes
for cooling to energize due to the compressor
lockout feature.
:
I2:00
Su
PM
On the thermostat, slide the Mode Switch to
OFF. Slide the Fan Switch to Fan On. The
fan should turn on and run continuously.
Page 13
INSTALLATION INSTRUCTIONS
T1045
Trouble Shooting
:
I2:00
PM
Su
:
I2:00
PM
Su
:
I2:00
Su
PM
SYMPTOM: The slide switches on the thermostat
are very difficult to move.
CAUSE: The backplate of the thermostat is
screwed too tightly into a wall that is not
perfectly flat.
REMEDY: Loosen the screws holding the
thermostat into the wall.
SYMPTOM: The Air Conditioning does not
attempt to turn on.
CAUSE: The cooling setpoint is set too
high, the Mode Switch is not set for
Cool, the batteries are too weak, or the
Aux Heat Switch is set for Emergency.
REMEDY: Consult the Normal Operation
section in the Owner’s Manual to:
Lower the cooling setpoint.
Correct the Mode Switch position.
Replace the batteries.
Slide the Aux Heat Switch to Normal.
SYMPTOM: The fan does not turn on even though
the compressor has energized.
CAUSE: The Fan Switch is not completely in the
On or Auto position.
REMEDY: Slide the Fan Switch firmly into the On
or Auto position.
Page 14
INSTALLATION INSTRUCTIONS
T1045
Trouble Shooting
:
I2:00
SYMPTOM: Aux Heat does not turn on.
CAUSE: The Aux Heat Switch is set for
Lockout.
REMEDY: Consult the Aux Heat section
of this manual to slide the Aux
Heat Switch to Normal (Page 7 of the
Owner’s Manual).
PM
Su
:
I2:00
SYMPTOM: The Heating does not attempt
to turn on.
CAUSE: The heating setpoint is set too
high, the Mode Switch is not set for
Heat, the batteries are too weak, or the
Aux Heat Switch is set for Emergency.
REMEDY: Consult the Normal Operation
section in this manual to:
Raise the heating setpoint.
Correct the Mode Switch position.
Replace the batteries.
Slide the Aux Switch to Normal.
PM
Su
P/N 88-637
Rev. 3
4Z95
Page 15
INSTALLATION INSTRUCTIONS
T1045
Warranty
One-Year Warranty - This Product is warranted to be free from defects in material and
workmanship. If it appears within one year from the date of original installation, whether or not
actual use begins on that date, that the product does not meet this warranty, a new or
remanufactured part, at the manufacturer’s sole option to replace any defective part, will be
provided without charge for the part itself provided the defective part is returned to the distributor
through a qualified servicing dealer.
THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS incurred for diagnosing, repairing,
removing, installing, shipping, servicing or handling of either defective parts or replacement
parts. Such costs may be covered by a separate warranty provided by the installer.
THIS WARRANTY APPLIES ONLY TO PRODUCTS IN THEIR ORIGINAL INSTALLATION LOCATION AND
BECOMES VOID UPON REINSTALLATION.
LIMITATIONS OF WARRANTIES – ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF
FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO
THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS
ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE
EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED,
ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER. ALL
WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING
HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS THEIR
WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY.
THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR:
1. Normal maintenance as outlined in the installation and servicing instructions or owner’s
manual, including filter cleaning and/or replacement and lubrication.
2. Damage or repairs required as a consequence of faulty installation, misapplication,
abuse, improper servicing, unauthorized alteration or improper operation.
3. Failure to start due to voltage conditions, blown fuses, open circuit breakers or other
damages due to the inadequacy or interruption of electrical service.
4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or
other conditions beyond the control of the Manufacturer.
5. Parts not supplied or designated by the Manufacturer, or damages resulting from their use.
6. Manufacturer products installed outside the continental U.S.A., Alaska, Hawaii, and
Canada.
7. Electricity or fuel costs or increases in electricity or fuel costs for any reason whatsoever
including additional or unusual use of supplemental electric heat.
8. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY
NATURE WHATSOEVER. Some states do not allow the exclusion of incidental or
consequential damages, so the above may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which may
vary from state to state.