Download Chauvet Intimidator Color DMX-500 User manual

Transcript
DMX-500
Intimidator Color™
USER MANUAL
th
Chauvet, 3000 N 29 Ct, Hollywood, FL 33020 U.S.A
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
TABLE OF CONTENT
BEFORE YOU BEGIN........................................................................................................................................................... 3
WHAT IS INCLUDED ................................................................................................................................................................................ 3
UNPACKING INSTRUCTIONS .................................................................................................................................................................... 3
AC POWER........................................................................................................................................................................................... 3
SAFETY INSTRUCTIONS .......................................................................................................................................................................... 3
INTRODUCTION ................................................................................................................................................................... 4
FEATURES ............................................................................................................................................................................................ 4
DMX CHANNEL SUMMARY ..................................................................................................................................................................... 4
PRODUCT OVERVIEW ............................................................................................................................................................................ 5
SETUP ................................................................................................................................................................................... 6
LAMP ................................................................................................................................................................................................... 6
Lamp installation ................................................................................................................................................................................................ 6
POWER ................................................................................................................................................................................................ 6
MOUNTING ........................................................................................................................................................................................... 7
Orientation .......................................................................................................................................................................................................... 7
Rigging ............................................................................................................................................................................................................... 7
MANUAL FOCUSING ............................................................................................................................................................................... 7
FUSE REPLACEMENT ............................................................................................................................................................................. 7
OPERATING INSTRUCTIONS.............................................................................................................................................. 8
OPERATING MODES............................................................................................................................................................................... 8
Stand Alone .................................................................................................................................................................. 8
Master/Slave ................................................................................................................................................................. 8
Master/Slave settings ......................................................................................................................................................................................... 8
Master/Slave Show Customization .................................................................................................................................................................... 9
DMX Mode .................................................................................................................................................................... 9
Setting the starting address ............................................................................................................................................................................... 9
APPENDIX........................................................................................................................................................................... 11
DMX PRIMER ..................................................................................................................................................................................... 11
Fixture Linking .................................................................................................................................................................................................. 11
DMX CHANNEL VALUES ...................................................................................................................................................................... 12
MAINTENANCE .................................................................................................................................................................................... 13
RETURNS PROCEDURE ........................................................................................................................................................................ 13
CLAIMS .............................................................................................................................................................................................. 13
GENERAL TROUBLESHOOTING .............................................................................................................................................................. 14
TECHNICAL SPECIFICATIONS ................................................................................................................................................................ 15
DMX-500 User Manual
2
Revision: 10/11/2006 1:11 PM
BEFORE YOU BEGIN
What is included
¾
¾
¾
¾
Intimidator Color™ (DMX-500)
Power cord with plug
ELC 24V 250W MR-16 lamp
Manual with Warranty Card
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts
are present, and have been received in good condition. Notify the shipper immediately and retain packing
material for inspection if any parts appear damaged from shipping or the carton itself shows signs of
mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the
factory, it is important that the fixture be returned in the original factory box and packing.
AC Power
To determine the power requirements for a particular fixture, see the label affixed to the back plate of the
fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average current draw
under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a
rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel
Figure 1 - AC Voltage Switch
is used solely for a 0% to 100% switch. Before applying power to a fixture, check that
the source voltage matches the fixture’s requirement. Check the fixture or device
carefully to make sure that if a voltage selection switch exists that it is set to the
correct line voltage you will use.
Warning!
Verify that the power select switch on your unit matches the
line voltage applied. All fixtures must be connected to circuits with a suitable Earth
Ground.
Safety Instructions
Please read these instructions carefully, which
includes important information about the
•
•
•
•
•
•
•
Please keep this User Guide for future consultation. If you
sell the unit to another user, be sure that they also receive
this instruction booklet.
Always make sure that you are connecting to the proper
voltage and that the line voltage you are connecting to is
not higher than that stated on decal or rear panel of the
fixture.
This product is intended for indoor use only!
To prevent risk of fire or shock, do not expose fixture to
rain or moisture. Make sure there are no flammable
materials close to the unit while operating.
The unit must be installed in a location with adequate
ventilation, at least 50cm from adjacent surfaces. Be sure
that no ventilation slots are blocked.
Always disconnect from power source before servicing or
replacing lamp or fuse and be sure to replace with same
lamp source.
Caution!
•
•
•
•
•
•
Secure fixture to fastening device using a safety chain.
Never carry the fixture solely by its head. Use its carrying
handles.
Maximum ambient temperature is Ta: 40°. Do not operate
fixture at temperatures higher than this.
In the event of serious operating problem, stop using the
unit immediately. Never try to repair the unit by yourself.
Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest
authorized technical assistance center. Always use the
same type spare parts.
Don’t connect the device to a dimmer pack.
Make sure power cord is never crimped or damaged.
Never disconnect power cord by pulling or tugging on the
cord.
Avoid direct eye exposure to lamp while it is on.
There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET.
DMX-500 User Manual
3
Revision: 10/11/2006 1:11 PM
INTRODUCTION
The Intimidator Color™ DMX-500 brings the latest automated intelligent lighting technology to a super
compact and affordable fixture. The Intimidator Color™ features a super bright 250 watt halogen bulb
encased in a highly optimized dichroic reflector ensuring optimum lamp performance. DMX-512 control
means total control of your light show and an internal microphone enables sound activated programs to
perform seamlessly. The Intimidator Color(tm) is best suited for small clubs and mobile DJs. Weighing only
15 lbs, any mobile DJ can truly appreciate its portability and extreme power. Ideal show conditions would
include 4 or more Intimidator Color(tm)s and an atmospheric effect device such as a fogger or hazer.
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
advanced 4 channel DMX-512 fixture
14 colors plus open
diffusion filter for color wash effect (installed)
electronic dimming
manual focus
reliable micro-stepping motors
built-in beat activated programs
built-in microphone
automatically enters stand-alone mode when no DMX signal is present
fan cooled
linkable via master/slave controller
programmable via any universal DMX controller
thermal fuse protection
switch-selectable power setting 115V/230V
2 year warranty
DMX Channel Summary
CHANNEL
FUNCTION
1
Speed
2
Color
3
Strobe
4
Dimmer
DMX-500 User Manual
4
Revision: 10/11/2006 1:11 PM
Introduction
Product Overview
DMX Input
Locking 3-pin XLR
male socket
Lamp Cover
Remove screw
to slide out
DMX Output
Locking 3-pin XLR
female socket
Power Input
Fuse Holder
Dipswitches
Provided for
DMX channel
addressing
Audio Sensitivity
(POT)
Adjust audio
sensitivity to
improve fixture
response
Integrated Mic
Top Cover also Lamp
cover
Hanging Bracket
(Yoke)
Yoke tensioning knob
Manual Focus Lens Gun
DMX-500 User Manual
5
Revision: 10/11/2006 1:11 PM
SETUP
Lamp
You will need to install a lamp prior to the initial operation of the fixture. An ELC 250W halogen lamp is
included.
Warning!
When replacing the lamp, please wait 15 minutes after powering down to allow the
unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp with
alcohol and wipe it with a lint free cloth before installation.
LA M P IN STA LLA T ION
1)
Remove the lamp cover screw and slide our lamp cover.
2)
Remove the top cover completely to expose lamp cage.
3)
Make sure the lamp is no longer hot before handling. Hold the lamp by its base and slide it
upwards until it is free from the retaining clips. Disconnect lamp from lamp socket.
4)
Connect a new lamp to the lamp socket and follow the same procedure as above to insert lamp
into lamp cage.
5)
Replace top cover and screw.
6)
No lamp alignment is necessary for this fixture.
Remove
Philips
screws to
remove unit
Unit with top
cover
removed and
lamp
Power
Warning!
Verify that the power label on your unit matches the line voltage applied. All fixtures
must be connected to circuits with a suitable Earth Ground.
•
•
•
•
•
To determine the power requirements for a particular fixture, see the label affixed to the back plate of
the fixture or refer to the fixture’s specifications chart.
A fixture’s listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable
resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100%
switch.
Before applying power to a fixture, check that the source voltage matches the fixture’s requirement.
All fixtures must be connected to circuits with a suitable Earth Ground.
DMX-500 User Manual
6
Revision: 10/11/2006 1:11 PM
Setup
Mounting
ORIENTATION
This fixture may be mounted in any position provided there is adequate room for ventilation.
R IG G IN G
It is important never to obstruct the fan or vents pathway. Mount the fixture
using, a suitable “C” or “O” type clamp. Adjust the angle of the fixture by
loosening both knobs and tilting the fixture. After finding the desired position,
retighten both knobs.
•
•
•
When selecting installation location, take into consideration lamp
replacement access and routine maintenance.
Safety cables should always be used.
Never mount in places where the fixture will be exposed to rain, high
humidity, extreme temperature changes or restricted ventilation.
Hanging Clamp
Note!
Clamp is sold separately.
Manual Focusing
IN
To adjust the focus, please follow the instructions below.
1)
2)
If operating in stand alone mode, turn the music
down so that the unit temporarily stops any activity,
other wise turn the lamp on using Channel 4.
Rotate the lens gun either clockwise or counterclockwise until the spot is defined by a hard edge.
Rotate lens gun
clockwise and
counterclockwise to
achieve desired
Fuse Replacement
Disconnect the power cord before replacing a
fuse and always replace with the same type fuse.
With a flat head screwdriver wedge the fuse holder out of its
housing. Remove the damaged fuse from its holder and
replace with exact same type fuse. Insert the fuse holder
back in its place and reconnect power.
DMX-500 User Manual
7
The fuse is located
inside this
compartment.
Remove using a flat
head screwdriver.
Revision: 10/11/2006 1:11 PM
OPERATING INSTRUCTIONS
Operating Modes
The Intimidator Color™ DMX-500 can be operated in three ways.
•
•
•
A stand-alone mode will listen to sound and run through its diverse range of built in programs.
Master/Slave mode will allow the command of up to as many units you want in a synchronized light
show to the sound.
DMX control mode will provide the greatest flexibility and creativity. Each fixture trait can be controlled
individually using any universal DMX-512 controller.
Stand Alone
The Stand Alone mode is activated automatically when the fixture is absent of DMX signal or a controller is
not connected. The Intimidator Color(tm) will run through its built in programs as it listens to the sound.
Master/Slave
The Master/Slave mode will allow you to link up to as many units you want in a daisy chain fashion. In this
mode, the first unit in the daisy chain will automatically command all other units following. The programs are
constructed based on the control of four units. Connecting the Intimidator Color(tm)s for (Master/Slave)
operation does not require any menu or setting selections. Simply connect each Intimidator Color(tm) in a
daisy like fashion using qualified 3 pin DMX cables as described below.
MASTER /SLAVE SETTIN GS
1)
Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector
of the first fixture.
2)
Connect the end of the cable coming from the first fixture which will have a (female) 3 pin
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then,
proceed to connect from the output as stated above to the input of the following fixture and so on
as illustrated below.
The built in programs were created using a set of 4 fixtures. When connecting fixtures together,
Daisy Chain Connection
Optional
leaving all dipswitches in the off position will enable the
auto-location function. The auto-location function will
automatically enumerate units in sets of four and will
execute the programs based on a 4 fixture show.
All dipswitches in the OFF position will enable the autolocation method.
Note!
For additional information on linking fixtures read under section “DMX Primer”
DMX-500 User Manual
8
Revision: 10/11/2006 1:11 PM
Operating Instructions
M AST ER /SLA VE SHOW CU ST OM IZAT ION
You can manually assign a slave device number to the fixtures by adjusting the dip-switches as illustrated
below. This provides a way for you to customize the playback such as creating unison movement across
selections or counter movements.
MANUAL SLAVE SETTINGS
FIXTURE 1
FIXTURE 2
FIXTURE 3
FIXTURE 4
DMX Mode
Operating in a DMX Control mode environment gives the user the greatest flexibility when it comes to
customizing or creating a show. You can tailor your programming to suit a specific event. Whether it is a
wedding where a spot light may be required or a lead singer requiring a color solo, the opportunities are end
less. In this mode you will be able to control each individual trait of the fixture independently.
SETTING TH E STAR TING ADDRESS
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start
address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data on the
channel indicated by the start address. For example, a fixture that occupies or uses 6 channels of DMX and
was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and
105. Choose start addresses so that the channels used do not overlap and notate the start address selected
for future reference.
If this is your first time addressing a fixture using the DMX-512 control protocol then I suggest jumping to the
Appendix Section and read the heading “DMX Primer”. It contains very useful information that will help you
understand its use.
Set the start address using the group of DIP switches located usually on bottom of the fixture. Each dip
switch has an associated value. Adding the value of each switch in the ON position will provide the start
address. Determining which switches to toggle ON given a specific start address can be accomplished in the
DMX-500 User Manual
9
Revision: 10/11/2006 1:11 PM
Operating Instructions
following manner. By subtracting the largest switch value possible from the selected start address which
does not cause a negative number.
EXAMPLE STARTING
ADDRESS
THE CHANNEL ADDRESSES WERE SELECTED AT RANDOM. IT IS RECOMMENDED TO SEQUENCE
YOUR FIXTURES FOLLOWING A NUMERICAL ORDER.
Address 10
Pin # 4 = 8
Pin # 2 = 2
Total
= 10
DMX Values
Address 24
Pin # 5 = 16
Pin # 4 = 8
Total
= 24
Resolving address
using simple math.
Address 233
DMX Values
233 – (128) = 105, Turn ON Dip # 8
105 – (64) = 41, Turn ON Dip # 7
41 – (32) = 9, Turn ON Dip # 6
9 – (8) = 1, Turn ON Dip # 4
1 – (1) = 0, Turn ON Dip # 1
You will most likely use the first available
number which maybe number 1. This
number was selected for example
purposes.
DMX-500 User Manual
10
DIP SWITCH
(DMX VALUE)
1
2
3
4
5
6
7
8
9
10
1
2
4
8
16
32
64
128
256
Revision: 10/11/2006 1:11 PM
APPENDIX
DMX Primer
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture
capable of receiving DMX 512 will require one or a number of sequential channels. The user must assign a
starting address on the fixture that indicates the first channel reserved in the controller. There are many
different types of DMX controllable fixtures and they all may vary in the total number of channels required.
Choosing a start address should be planned in advance. Channels should never overlap. If they do, this will
result in erratic operation of the fixtures whose starting address is set incorrectly. You can however, control
multiple fixtures of the same type using the same starting address as long as the intended result is that of
unison movement or operation. In other words, the fixtures will be slaved together and all respond exactly
the same.
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is where
the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are
connected is not important and has no effect on how a controller communicates to each fixture. Use an
order that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor
twisted pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2
is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET carries 3-pin XLR DMX compliant cables,
DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)
F I X T URE L I NKING
Figure 2 - DMX connector configuration
1
3
2
COMMON
1
3
INPUT
2
Note!
1
3
2
DMX +
DMX -
Resistance 120
ohm 1/4w between
pin 2 (DMX -) and
pin 3 (DMX +) of
the last fixture.
OUTPUT
Termination reduces signal errors and to
avoid signal transmission problems and
interference, it is always advisable to
connect a DMX signal terminator.
If you use a controller with a 5 pin DMX output connector, you will need to use a 5
pin to 3 pin adapter. Chauvet Model No: DMX5M.
The chart below details a proper cable conversion:
3 PIN TO 5 PIN CONVERSION CHART
CONDUCTOR
3 Pin Female (output)
5 Pin Male (Input)
GROUND/SHIELD
Pin 1
Pin 1
DATA ( - )SIGNAL
Pin 2
Pin 2
DATA ( + ) SIGNAL
Pin 3
Pin 3
DO NOT USE
Do not use
DO NOT USE
Do not use
DMX-500 User Manual
11
Revision: 10/11/2006 1:11 PM
Appendix
DMX Channel Values
Channel
Value
Function
1
000 Ù 219
220 Ù 239
240 Ù 255
Speed
Fast > Slow
Sound activated mode; Slow
Sound activated mode; Fast
2
000 Ù 009
010 Ù 019
020 Ù 029
030 Ù 039
040 Ù 049
050 Ù 059
060 Ù 069
070 Ù 079
080 Ù 089
090 Ù 099
100 Ù 109
110 Ù 119
120 Ù 129
130 Ù 139
140 Ù 149
150 Ù 159
160 Ù 255
Color
Closed
White/Open
Magenta
Amber
Cyan
Dark Green
Pink
Blue
Red
Yellow
Green
Dark Red
Dark Pink
UV-Purple
Light Blue
Orange
Color Scroll: Speed set by channel (1)
3
000 Ù 100
101 Ù 120
121 Ù 140
141 Ù 160
161 Ù 180
181 Ù 200
201 Ù 255
Strobe
No Strobe
1 strobe per second
2 strobes per second
3 strobes per second
4 strobes per second
5 strobes per second
6 strobes per second
4
000 Ù 255
Dimming
0% Ù 100%
DMX-500 User Manual
12
Revision: 10/11/2006 1:11 PM
Appendix
Maintenance
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and
environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned
at least twice a month. Dust build up reduces light output performance and can cause overheating. This can
lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting
maintenance.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected on
external vents and internal components. Clean all glass when the fixture is cold with a mild solution of glass
cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to the cloth or
tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they are free of
haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil and dirt can cause damage and
premature aging of the lamp. In the event that the lamp is touched or becomes dirty, clean the lamps with an
alcohol wipe.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. Clean with
soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean the external optics at
least every 20 days. Clean the internal optics at least every 30/60 days.
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be
prepared to provide the model number, serial number and a brief description of the cause for the return. Be
sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer’s
responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a
suggestion, proper UPS packing or double-boxing is always a safe method to use.
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to
the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with
the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing
component/part, damage not related to shipping, and concealed damage, must be made within seven (7)
days of receiving merchandise.
DMX-500 User Manual
13
Revision: 10/11/2006 1:11 PM
Appendix
General Troubleshooting
Applies to
Symptom
Solution(s)
Light
s
Auto shut off
Check fan thermal switch reset
9
Beam is very dim or not
bright
Clean optical system or replace lamp
Controlle
rs
Dimme
rs&
Chaser
9
Check 220/110v switch for proper setting
Breaker/Fuse keeps
blowing
Check total load placed on device
Chase is too slow
Check users manual for speed adjustment
Device has no power
Fogge
rs &
Snow
Check for power on Mains.
9
9
9
9
9
9
9
9
9
9
9
Check device’s fuse. (internal and/or external)
Fixture is not
responding
Check DMX Dip switch settings for correct addressing
Check DMX cables
Check polarity switch settings
Fixture is on but there
is no movement to the
audio
Make sure you have the correct audio mode on the control
switches. If audio provided via ¼” jack, make sure a live
audio signal exists
9
9
Adjust sound sensitivity knob
Lamps cuts off
sporadically
Possible bad lamp or fixture is overheating.
Light will not come on
after power failure
Some discharge lamps require a cooling off period before
the electronics in the fixture can kick start it again, wait 5 to
10 minutes before powering up
Loss of signal
Use only DMX cables
9
Lamp may be at end of its life.
9
Install terminator
Note: Keep DMX cables separated from power cables or
black lights.
9
Moves slow
Check 220/110v switch for proper setting
9
No flash
Re-install bulb, may have shifted in shipping
9
No laser output
Bounce mirror motor may have shifted during shipping,
readjust
9
No light output
Check slip ring & brushes for contact
Install bulb
9
9
Call service technician
Relay will not work
Check reset switch
9
Check cable connections
Remote does not work
Make sure connector is firmly connected to device
9
Stand alone mode
All Chauvet lighting fixtures featuring stand-alone functions
do not require additional settings, simply power the fixture
and it will automatically enter into this mode
9
DMX-500 User Manual
14
9
Revision: 10/11/2006 1:11 PM
Appendix
Technical Specifications
WEIGHT & DIMENSIONS
Length...................................................................................................................... 279.4 mm (11.00 in)
Width ......................................................................................................................... 196.9 mm (7.75 in)
Height ........................................................................................................................ 247.7 mm (9.75 in)
Weight .............................................................................................................................. 3.63 Kg (8 lbs)
POWER
Switch-selectable power setting ....................................................................115V 60 Hz or 230V 50 Hz
AC input......................................................................................... 3-prong IEC 60320 C14 male socket
LAMPS
ELC3............................................................................................................................300 hr, 250W 24V
THERMAL
Maximum ambient temperature............................................................................................ 40° (104° F)
FUSE
Main.......................................................................................................... 20mm Glass 3.15A Fast Blow
CONTROL & PROGRAMMING
Data input ................................................................................................ locking 3-pin XLR male socket
Data output ........................................................................................... locking 3-pin XLR female socket
Data pin configuration ..............................................................................pin 1 shield, pin 2 (-), pin 3 (+)
Protocols........................................................................................................................ DMX-512 USITT
DMX Channels .......................................................................................................................................4
ORDERING INFORMATION
Intimidator Color™ ....................................................................................................................DMX-500
Fuse..................................................................................................................................P170FUSE003
DMX-500 User Manual
15
Revision: 10/11/2006 1:11 PM