USER INSTRUCTIONS
FOR
IMMEDIATE RESPONSE
TECHNOLOGIES, INC.
M96 CARTRIDGE
PART NO. S-70020
NSN: 4240-01-574-9568
This cartridge shall only be used with NIOSH approved
IMMEDIATE RESPONSE TECHNOLOGIES systems. The
NIOSH approval label (see reverse) outlines the NIOSH-approved systems, and their components, that may be used with
the M96 Cartridge. Complete maintenance of systems and
operating instructions are detailed in your system’s user
manual.
The restrictions and limitations are outlined on the NIOSH
approval label (see reverse) and must be followed strictly.
Failure to do so may cause severe bodily injury or death.
Pre-Use
Failure to change the cartridges when needed reduces the
user’s protection, comfort, and may cause severe bodily injury or death. Make sure:
1)that the cartridge is appropriate for your application by
checking with your Local Safety Program Administrator
2)verify that the packaging is intact and confirm the following: that the cartridge part number on the wrap-around
label is S-70020, the word NIOSH is apparent, the expiration date date has not been passed
3)verify that the cartridge housing is not damaged. Using
damaged Cartridges may cause contamination to enter the
system and cause serious bodily injury or death;
4)verify that the filter seal for the Facepiece cartridge inlet
or the rubber gasket for the Powered Air Blower Assembly
cartridge port is in place and in good condition, and install/replace if necessary;
5)carefully thread the cartridge into the Facepiece or Powered Air Blower Assembly cartridge inlet until snug.
Storage
This cartridge shall be used as soon as possible after opening. However, the M96 Cartridge has an extended storage
life if stored unopened, out of direct sunlight and in a dry
environment. Note the expiration date on the cartridge body.
S-Special Use Limitations Apply
The IRT M96 Cartridge, when used with the C420 and
FlexAir PAPR Systems, meets NIOSH approval for organic
vapors, ammonia, acid gases (Chlorine, Chlorine Dioxide,
Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide
and Sulfur Dioxide), Formaldehyde, Methylamine and as an
HE Filter for powered air purifying respirator (PAPR).
The M96 Cartridge, when used with the Promask 2000 full
facepiece and the M95 full facecepiece, meets NIOSH approval for organic vapors, ammonia, acid gases (Chlorine,
Chlorine Dioxide, Hydrogen Chloride, Hydrogen Fluoride,
Hydrogen Sulfide and Sulfur Dioxide), Formaldehyde, Methylamine and as a P100 Filter for an air purifying respirator
(APR).
The C420 PAPR System, Promask 2000 facepiece, M95
facepiece (APRs) and M96 cartridge have been tested at canister levels for Tear Gas (CS & CN) and Phosphine and can
therefore be used as a gas mask for Tear Gas and Phosphine
only.
Disposal
These cartridges MUST be disposed of in strict accordance with local, state and/or federal regulations.
Failure to comply and follow the Disposal, Storage,
Use, Pre-use or Duration instructions as outlined in
these instructions may cause serious bodily injury or
DEATH to oneself or others.
Duration
The cartridge’s duration is determined by the atmosphere
and contaminant in which it is being used.
Refer to your user’s manual for specific details outlining the method of use and your actions.
However, the user:
1) must leave the contaminated area immediately if he/
she notices an increase in resistance or can detect (Taste or
Smell) an odor. The person must then follow the system’s
user manual’s instructions for cartridge changeout;
2)must change the cartridge if exposed to water.
Immediate Response Technologies, Inc.
7100 Holladay-Tyler Road
Glenn Dale, MD 20769
800 598-9711
P/N C-85095-001, Rev. 9
This manual could contain technical inaccuracies or typographical errors. Updates are made periodically to the information herein. If you have comments please forward them to Immediate Response
Technologies, Inc. Thank you.
IMMEDIATE RESPONSE TECHNOLOGIES, INC.
7100 HOLLADAY-TYLER ROAD
GLENN DALE, MD 20769
(800) 598-9711
Immediate Response Technologies IRT M96 CARTRIDGE
This Cartridge is approved only in the following configurations:
RESPIRATOR COM PONENTS
CAUTIONS AND
PROT ECT ION1
TC-
LIMITATIONS
23C-2457
HE/AM/CD/CL/FM /HC/HF/HS
X
/MA/OV/PH/SD/CS/CN
X
X
X
84A-5036
P100/AM/CD/CL/FM/HC/HF/
HS/MA/OV/PH/SD/CS/CN
X
X
X
23C-2458
HE/AM/CD/CL/FM /HC/HF/HS
/MA/OV/SD
84A-5175
P100/AM/CD/CL/FM/HC/HF/
HS/MA/OV/PH/SD/CS/CN
23C-2484
HE/AM/CD/CL/FM /HC/HF/HS
/MA/OV/SD
23C-2486
HE/AM/CD/CL/FM /HC/HF/HS
/MA/OV/PH/SD/CS/CN
23C-2497
HE/AM/CD/CL/FM /HC/HF/HS
/MA/OV/SD
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
ABCHJLMNOPSLL
X
X
OV - Organic Vapor
CL - Chlorine
PH - Phosphine
FM - Formaldehyde
SD - Sulfur Dioxide
HC - Hydrogen Chloride
HF - Hydrogen Fluoride
cs - Chlorobenzylidene Malononitrile
2. Cautions and Limitations
A- Not for use in atmospheres containing less than 19.5% oxygen
B- Not for use in atmospheres immediately dangerous to life or health.
C- Do not exceed maximum use concentrations established by regulatory standards
F- Do not use respirator if airflow is less than 115 lpm ( 4CFM) for tight fitting facepieces
or 170 lpm (6CFM) for hoods and/or helmet.
H- Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges
and canisters are replaced before breakthrough occurs.
I- Contains electrical parts that may cause an ignition in flammable or explosive
atmospheres.
J- Failure to properly use and maintain this product could result in injury or death.
L- Follow the manufacturer's User's Instructions for changing cartridges, canisters and/or filters.
M-All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA
and other applicable regulations.
N- Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as
specified by the manufacturer.
O- Refer to User's Instructions, and/or maintenance manuals for information on use and maintenance of
these respirators.
P- NIOSH does not evaluate respirators for use as surgical masks.
S- Special or critical User's Instructions and/or specific use limitations apply. Refer to User's Instructions before donning.
LL- This respirator contains filter or cartridge components that are not approved for all protections in all configurations.
Check the specific row on the NIOSH approval label to ensure proper use.
© 01/10 by Immediate Response Technologies, Glenn Dale, Maryland. All rights reserved.
ABCHJLMNOPSLL
X
X
ABCFHIJLMNOPLL
X
ABCFHIJLMNOPSLL
X
X
P100 - Particulate Filter (99.97% filter efficiency level) effective against all particulate aerosols
CD - Chlorine Dioxide
ABCFHIJLMNOPLL
X
HE - High Efficiency Particulate Air Filter For Powered, Air-purifying Respirators
MA - Methylamine
ABCFHIJLMNOPSLL
X
1. Protection
AM - Ammonia
2
HS - Hydrogen Sulfide
CN - Chloroacetophenone
X
ABCFHIJLMNOPLL