7.7 Fault list
Problem
Motor fault
Possible cause
mains voltage deviates more than
10% of the rated motor voltage
Too high cooling air temperature
Poor cable connection
Blown fuse
Too little cooling air caused by a
clogged cooling air passage
The motor hums and takes Defect winding
too much power
Loose wire
Action / Solution
Provide the correct voltage
Fuses are blown
Short circuit in wiring or motor
Rectify the short circuit
Motor short circuit to housing or
has a short in the windings
Turn to a repair shop to fix the short circuit
Motor is connected incorrectly
Connect the motor correct
Too little substrate in the bin
Fill the bin with substrate
Elevator provides little substrate
Door safety switch is open
Set the substrate conveyor faster
Close door and reset the safety circuit by pressing
the reset button
Pull Emergency Stop button and reset the safety
circuit by pressing the reset button
Reset the safety circuit by pressing the reset button
See why circuit breaker has tripped. Remove
obstacles to conveyors. Switch on the machine
after solving the problem.
Reduce cable length
Minimum substrate in the
trays
Machine does not start
Emergency stop button is not
pulled
Emergency stop button not reset
Breaker tripped in main cabinet
Cable length too large causing
voltage loss
Voltage fluctuations caused by
other devices on the same group
Provide cool air
check the cable connection and repair if necessary
Replace fuse
Ensure proper inlet and outlet of the cooling air
Repair or replace the motor winding
Lock wire
Ensure the correct voltage. Turn off other devices
7.8 Drawings and schemes
The drawings accompanying this machine are supplied in a separate file. The wiring diagrams are included in the
electrical cabinet of the machine.