Cellar Temperature is too Cold
Temperature is too Low when Unit is ON
Possible Cause
Solution
Controller set too low
Change set point on controller to higher
temperature.
(Note: controller is programmed at 55°F
when assembled at the factory)
Temperature is too Cold When Unit is OFF
Possible Cause
Solution
Too much heat lost to
adjacent areas.
Add more insulation around ductwork
and ensure doorways and glass panels
are sealed.
Cellar Temperature is too High
Temperature too High
Possible Cause
Solution
Controller set too high
Change set point on controller to lower
temperature.
(Note: controller is programmed at 55°F
when assembled at factory)
Check for blockage in supply or return
ductwork.
Check and clean filter and coil if needed.
Measure square footage of room and
confirm the unit being used is correct size
for room.
Make sure that you are using a high quality
door seal. If there is a gap between the
bottom of the door and the floor, the cool
air will sink and flow out beneath the door.
Not enough airflow from
evaporator
Confirm room size
Door seal