Download PowerFlex® 70 AC Drives

Transcript
Technical Data
PowerFlex® 70
AC Drives
Product Overview
PowerFlex® 70 AC Drive Technical Data
Optimized Simplicity
PowerFlex® 70 drives are designed to worldwide standards providing out-of-the-box
performance around the globe. Available ratings include: 0.5 to 25 Hp output at 240V
ac input, 0.5 to 50 Hp output at 480V ac input, 0.5 to 50 Hp output at 600V ac input.
The PowerFlex 70 drive can be used with a full featured LCD Human Interface
Module, which provides multilingual text for startup, metering, programming and
troubleshooting.
The PowerFlex 70 can be programmed for either Volts per Hertz, Sensorless Vector or
Vector Control with Force Technology to cover a wide range of applications from fans
to extruders.
Optional internal communication modules provide fast and efficient control and/or
data exchange with host controllers over popular interfaces. These interfaces include:
DeviceNet™, EtherNet, ControlNet™, Remote I/O, Serial Communications and other
open control and communication networks. PC tools such as DriveExplorer™ and
DriveTools™ SP assist with programming, monitoring, and troubleshooting the
PowerFlex 70.
Table of Contents
Description
Page
Product Overview
Flexible Packaging and Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Space Saving Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Easy to Use Human Interface Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Control and Performance Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unsurpassed Capability in Network Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Product Selection Guide
Catalog Number Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Stock Products Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Standard Drives Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Packaged Drives Program
Packaged Drives Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Quick Ship Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Standard Packaged Drives Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Engineered Drives Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Approximate Dimensions – Standard Packaged Drives Program . . . . . . . . . . . . . . . . . . 20
Installation Considerations
Power Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Control Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Specifications
Safe Off Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Encoder Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Branch Circuit Protection Devices and Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . 26
Maximum Lead Lengths (in feet). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Control and Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Parameter List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Approximate Dimensions – PowerFlex 70 Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Approximate Dimensions – Medium Duty External Dynamic Brake Resistors . . . . . . . 34
2
Product Overview
Flexible Packaging and Mounting
IP20, NEMA Type 1 – For conventional mounting inside or
outside a control cabinet. Conduit plate is vertically removable
for easy installation and replacement without disturbing conduit.
IP66, NEMA Type 4X/12 (Indoor Use) – For mounting directly
in the production environment. Listed by UL to resist dust, dirt,
etc. and to survive high pressure water spray. Also certified by
NSF to assure conformity with international food equipment
standards.
Flange Type – For mounting heatsink through back of an
enclosure, thus removing a large portion of the heat inside a
cabinet. The backside is rated IP66 and UL (NEMA) Type 4X/12
for both indoor and outdoor use.
Space Saving Hardware Features
Zero Stacking™ - Drives can be mounted directly next to one another with no reduction of ambient temperature rating
(50° C).
Integral EMC Filtering provides a compact, all-in-one package solution for meeting EMC requirements, including CE
in Europe.
Integral Dynamic Brake Transistor delivers a cost-effective means of switching regenerative energy without costly
external chopper circuits.
Internal Dynamic Brake Resistor requires no extra panel space, and supplies a large amount of braking torque for short
periods.
Easy to Use Human Interface Tools
PowerFlex 7-Class LCD Human Interface Modules provide:
• Large and easy to read 7 line backlit display
• Variety of languages (English, French, German, Italian, Spanish, Portuguese, Dutch)
• Alternate function keys for shortcuts to common tasks
• “Calculator-like” number pad for fast and easy data entry (Full Numeric version only)
• Control keys for local start, stop, speed, and direction
• Remote versions for panel mount applications
Family of PC based configuration tools:
• DriveExplorer and DriveExplorer Lite: A simple and
flexible “On-line” tool for monitoring and configuration
while connected to a drive.
• DriveTools™ SP: A suite of software tools which provide
an intuitive means for programming, troubleshooting and
maintaining Allen-Bradley AC and DC drives.
3
Product Overview
Control and Performance Features
Vector Control with Force Technology ➊ provides outstanding torque and speed regulation, with or without encoder
feedback.
Sensorless Vector Control develops high torque over a wide speed range, and
adapts to individual motor characteristics.
Fast acting Current Limit and Bus Voltage Regulation result in maximum
acceleration and deceleration without tripping.
Flying Start delivers smooth connection into rotating loads, regardless of
commanded direction, without the need for any speed feedback device.
PI Control can eliminate the need for a separate process loop controller.
Inertia Ride-Through offers tripless operation during a prolonged power
outage by using the rotating energy stored in high inertia, low friction loads.
User Sets, allowing up to three complete sets of parameter data, can be
individually loaded for different batch processes.
Slip compensation delivers minimum of 0.5% open loop speed regulation
across a wide speed range, eliminating the need for speed feedback devices in
some applications.
Safe Off Option ➊, the first offering available within the DriveGuard™ series
of safety solutions, prevents a drive from delivering rotational energy to motors
by integrating a safety circuit with the drive’s power switching signals. This
solution meets EN 954-1, Category 3.
Droop Control ➊ for load sharing applications.
Sleep/Wake Control ➊ for analog control of start and stop.
➊ Feature available for Enhanced Control only.
4
Product Overview
Unsurpassed Capability in Network Communications
PowerFlex 70 drives are fully compatible with
Allen-Bradley drive’s wide variety of DPI
communication adapters, offering the following
benefits:
Esc
Sel
Jog
✔
✔
Bluetooth®
✔
Siemens P1 FLN
✔
Metasys N2
✔
Modbus RTU
✔
LonWorks
✔
Interbus
✔
PROFIBUS
EtherNet/IP
✔
RS-485 DF1
ControlNet
✔
Remote I/O
DeviceNet
Alt
(Unconnected Messaging) permits other network devices (e.g. PanelView) to
communicate directly to a drive without routing the communication through the network
scanner.
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
Adapter Routing -- Plug PC into one drive and talk to other Allen-Bradley drives on
same network, without being routed through the network scanner.
✔
Access to 100% of all parameters over the network.
✔
AutoBaud capability makes initial connections less problematic.
✔
Change Of State significantly reduces network traffic by configuring control messages
to be sent only upon customer defined states. Very flexible configuration for each node
(Example: “reference must change by more than 5%”).
✔
✔
Peer Control provides master slave type control between drives, where one or more
slave drives (consumers) can run based on the status of a master drive (producer), which
can also significantly reduce network traffic.
✔
✔
ADR (Automatic Device Replacement) saves significant time and effort when
replacing a drive, by allowing the scanner to be configured to automatically detect a new
drive and download the required parameter settings.
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
Flexible Fault Configuration – Adapters can be programmed to take fault based
actions such as ramp to stop, cost to stop, and hold last state, as well as send user
configurable logic control and speed reference values. In addition, different actions can be
taken based on whether the network experienced a serious problem (broken cable etc.)
versus a network idle condition (PLC set to “Program”).
5
Product Selection Guide
Catalog Number Explanation
20A
Drive
B
2P1
Voltage Rating Rating
A
3
Enclosure
A
Y
HIM (1) Documentation
Code Type
20A 70
Y
Brake IGBT
Code Type
A
English Manual (2)
N
No Manual
N
Brake Resistor
N
Emission Class
Comm Slot
Code w/Brake Resistor
Y
Yes
N
No
Code
N
C
G(5)
C
0
Control & I/O (3)
Feedback
Control
Standard
Enhanced
Enhanced
Safe-Off
N/A
No
Yes
Code w/Brake IGBT
Y
Yes
Code
B
C
D
E
Voltage
240V ac
400V ac
480V ac
600V ac
Code
0
2
3
5
Ph.
3
3
3
3
Code
A
C
F
G
Interface Module
Blank HIM
Digital LCD HIM
Full Numeric LCD HIM
Prog. Only LCD HIM
Code
C
D
E
H
R
S
N
Code Rating
A
Filtered (Excluding 600V ac)
A(4) & B Frames (Optional)
C, D & E Frames (Standard)
N
Not Filtered
A & B Frames (Optional)
C, D & E Frames NA (600V ac only)
Enclosure
Panel Mount - IP 20, NEMA Type 1
Wall/Machine Mount = IP66, NEMA 4X/12 (Indoor Use)
Flange Mount - Front = IP 20, NEMA Type 1; Heatsink = IP66, NEMA Type 4X/12
Wall/Machine Mount = IP54, NEMA Type 12
(1)
(2)
(3)
(4)
(5)
Version
ControlNet (Coax)
DeviceNet
EtherNet/IP
RS485 HVAC
RIO
RS485 DF-1
N/A
Code
N
0
1
Feedback
N/A
None
5V/12V Encoder
IP66, NEMA 4X/12 (Code C) is available only
with HIM codes 0, 3, or 5.
Multilingual Quick Start also included.
Frame E ratings are only available with
Enhanced Control.
Increases A Frame size to B.
Not available as factory installed option for
600V ratings.
Output Current @ 600V 60Hz Input
Output Current @ 480V 60Hz Input Output Current @ 400V 50Hz Input
Output Current @ 240V 60Hz Input
Output Current @ 208V 60Hz Input
Code
0P9
1P7
2P7
3P9
6P1
9P0
011
017
022
027
032
041
052
Code
1P1
2P1
3P4
5P0
8P0
011
014
022
027
034
040
052
065
Code
2P2
4P2
6P8
9P6
015
022
028
042
054
070
Code
2P2
4P2
6P8
9P6
015
022
028
042
054
070
6
Amps
0.9
1.7
2.7
3.9
6.1
9.0
11
17
22
27
32
41
52
kW (Hp)
0.37 (0.5)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
4.0 (5.0)
5.5 (7.5)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
22 (30)
30 (40)
37 (50)
Amps
1.1
2.1
3.4
5.0
8.0
11
14
22
27
34
40
52
65
kW (Hp)
0.37 (0.5)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
3.7 (5.0)
5.5 (7.5)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
22 (30)
30 (40)
37 (50)
Code
1P3
2P1
3P5
5P0
8P7
011
015
022
030
037
043
060
072
Amps
1.3
2.1
3.5
5.0
8.7
11.5
15.4
22
30
37
43
60
72
kW (Hp)
0.37 (0.5)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
4.0 (5.0)
5.5 (7.5)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
22 (30)
30 (40)
37 (50)
Amps
2.2
4.2
6.8
9.6
15.3
22
28
42
54
70
kW (Hp)
0.37 (0.5)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
4.0 (5.0)
5.5 (7.5)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
Amps
2.5
4.8
7.8
11
17.5
25.3
32.2
43
62.1
78.2
kW (Hp)
0.37 (0.5)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
4.0 (5.0)
5.5 (7.5)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
Product Selection Guide
Stock Products Program
PowerFlex 70 Drives — Panel Mount - IP 20, NEMA Type 1
200-240V ac, Three-Phase Drives
Output Amps
240V ac Input ➊
Cont.
1 Min.
2.2
4.2
6.8
9.6
15.3
22
28
42
54
70
2.4
4.8
9.0
10.6
17.4
24.2
33
46.2
63
81
(For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
3 Sec.
208V ac Input
Cont.
1 Min.
3.3
6.4
12
14.4
23.2
33
44
63
84
108
2.5
4.8
7.8
11
17.5
25.3
32.2
43
62.1
78.2
2.7
5.5
10.3
12.1
19.2
27.8
37.9
55.5
72.4
93.1
IP20, NEMA Type 1 with HIM
3 Sec.
Nominal Power Ratings
Normal Duty
Heavy Duty
kW
Hp
kW
Hp
Catalog Number
20A…
Frame Size
3.7
7.4
13.8
16.5
26.2
37.9
50.6
74
96.6
124
0.37
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
B2P2A3AYNNNC0
B4P2A3AYNNNC0
B6P8A3AYNNNC0
B9P6A3AYNNNC0
B015A3AYNANC0
B022A3AYNANC0
B028A3AYNANC0
B042A3AYNANC0
B054A3AYNANC0
B070A3AYNANC0
A
A
B
B
C
D
D
D
E
E
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
11
15
0.33
0.75
1.5
2.0
3.0
5.0
7.5
10
15
20
380-480V ac, Three-Phase Drives (For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
Output Amps
480V ac Input ➊
Cont.
1 Min.
1.1
2.1
3.4
5.0
8.0
11
14
22
27
34
40
52
65
1.2
2.4
4.5
5.5
8.8
12.1
16.5
24.2
33
40.5
51
60
78
3 Sec.
380-400V ac Input
Cont.
1 Min. 3 Sec.
Nominal Power Ratings
Normal Duty
Heavy Duty
kW
Hp
kW
Hp
Catalog Number
20A…
Frame Size
1.6
3.2
6.0
7.5
12
16.5
22
33
44
54
68
80
104
1.3
2.1
3.5
5.0
8.7
11.5
15.4
22
30
37
43
60
72
0.37
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
D1P1A3AYNNNC0
D2P1A3AYNNNC0
D3P4A3AYNNNC0
D5P0A3AYNNNC0
D8P0A3AYNNNC0
D011A3AYNANC0
D014A3AYNANC0
D022A3AYNANC0
D027A3AYNANC0
D034A3AYNANC0
D040A3AYNANC0
D052A3AYNANC0
D065A3AYNANC0
A
A
A
B
B
C
C
D
D
D
D
E
E
1.4
2.4
4.5
5.5
9.9
13
17.2
24.2
33
45
56
66
90
1.9
3.2
6.0
7.5
13.2
17.4
23.1
33
45
60
74
90
120
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
11
15
18.5
22
30
0.33
0.75
1.5
2.0
3.0
5.0
7.5
10
15
20
25
30
40
IP20, NEMA Type 1 with HIM
7
Product Selection Guide
Standard Drives Selection
PowerFlex 70 Drives — Panel Mount - IP 20, NEMA Type 1
200-240V ac, Three-Phase Drives
Output Amps
240V ac Input ➊
Cont.
1 Min.
2.2
4.2
6.8
9.6
15.3
22
28
42
54
70
2.4
4.8
9.0
10.6
17.4
24.2
33
46.2
63
81
(For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
3 Sec.
208V ac Input
Cont.
1 Min.
3.3
6.4
12
14.4
23.2
33
44
63
84
108
2.5
4.8
7.8
11
17.5
25.3
32.2
43
62.1
78.2
2.7
5.5
10.3
12.1
19.2
27.8
37.9
55.5
72.4
93.1
IP20, NEMA Type 1 with HIM
3 Sec.
Nominal Power Ratings
Normal Duty
Heavy Duty
kW
Hp
kW
Hp
Catalog Number
20A…
Frame Size
3.7
7.4
13.8
16.5
26.2
37.9
50.6
74
96.6
124
0.37
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
B2P2A0AYNNNC0
B4P2A0AYNNNC0
B6P8A0AYNNNC0
B9P6A0AYNNNC0
B015A0AYNANC0
B022A0AYNANC0
B028A0AYNANC0
B042A0AYNANC0
B054A0AYNANC0
B070A0AYNANC0
A
A
B
B
C
D
D
D
E
E
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
11
15
0.33
0.75
1.5
2.0
3.0
5.0
7.5
10
15
20
380-480V ac, Three-Phase Drives (For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
Output Amps
480V ac Input ➊
Cont.
1 Min.
1.1
2.1
3.4
5.0
8.0
11
14
22
27
34
40
52
65
1.2
2.4
4.5
5.5
8.8
12.1
16.5
24.2
33
40.5
51
60
78
3 Sec.
Nominal Power Ratings
Normal Duty
Heavy Duty
kW
Hp
kW
Hp
IP20, NEMA Type 1 with HIM
380-400V ac Input
Cont.
1 Min. 3 Sec.
Catalog Number
20A…
Frame Size
1.6
3.2
6.0
7.5
12
16.5
22
33
44
54
68
80
104
1.3
2.1
3.5
5.0
8.7
11.5
15.4
22
30
37
43
60
72
0.37
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
D1P1A0AYNNNC0
D2P1A0AYNNNC0
D3P4A0AYNNNC0
D5P0A0AYNNNC0
D8P0A0AYNNNC0
D011A0AYNANC0
D014A0AYNANC0
D022A0AYNANC0
D027A0AYNANC0
D034A0AYNANC0
D040A0AYNANC0
D052A0AYNANC0
D065A0AYNANC0
A
A
A
B
B
C
C
D
D
D
D
E
E
1.4
2.4
4.5
5.5
9.9
13
17.2
24.2
33
45
56
66
90
1.9
3.2
6.0
7.5
13.2
17.4
23.1
33
45
60
74
90
120
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
11
15
18.5
22
30
0.33
0.75
1.5
2.0
3.0
5.0
7.5
10
15
20
25
30
40
500-600V ac, Three-Phase Drives (For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
Output Amps
600V ac Input
Cont.
1 Min.
0.9
1.7
2.7
3.9
6.1
9.0
11
17
22
27
32
41
52
1.0
1.9
3.6
4.3
6.7
9.9
13.5
18.7
25.5
33
40.5
48
61.5
3 Sec.
Nominal Power Ratings
Normal Duty
kW
Hp
Heavy Duty
kW
Hp
Catalog Number
20A…
Frame Size
1.4
2.6
4.8
5.8
9.1
13.5
18
25.5
34
44
54
64
82
0.37
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
11
15
18.5
22
30
E0P9A0AYNNNC0
E1P7A0AYNNNC0
E2P7A0AYNNNC0
E3P9A0AYNNNC0
E6P1A0AYNNNC0
E9P0A0AYNNNC0
E011A0AYNNNC0
E017A0AYNNNC0
E022A0AYNNNC0
E027A0AYNNNC0
E032A0AYNNNC0
E041A0AYNANC0
E052A0AYNANC0
A
A
A
B
B
C
C
D
D
D
D
E
E
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
IP20, NEMA Type 1 with HIM
0.33
0.75
1.0
1.5
3.0
5.0
7.5
10
15
20
25
30
40
➊ Catalog code corresponds to output amps in these columns. Drive must be programmed to lower voltage to obtain higher currents shown at right.
8
Product Selection Guide
PowerFlex 70 Drives — Wall / Machine Mount - IP 66, NEMA Type 4X/12 (Indoor Use)
200-240V ac, Three-Phase Drives
Output Amps
240V ac Input ➊
Cont.
1 Min.
2.2
4.2
6.8
9.6
15.3
22
28
42
54
70
2.4
4.8
9.0
10.6
17.4
24.2
33
46.2
63
81
(For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
3 Sec.
208V ac Input
Cont.
1 Min.
3.3
6.4
12
14.4
23.2
33
44
63
84
108
2.5
4.8
7.8
11
17.5
25.3
32.2
42
62.1
78.2
2.7
5.5
10.3
12.1
19.2
27.8
37.9
55.5
72.4
93.1
IP66, NEMA Type 4X/12 with HIM
3 Sec.
Nominal Power Ratings
Normal Duty
Heavy Duty
kW
Hp
kW
Hp
Catalog Number
20A…
Frame
Size
3.7
7.4
13.8
16.5
26.2
37.9
50.6
74
96.6
124
0.37
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
B2P2C3AYNNNC0
B4P2C3AYNNNC0
B6P8C3AYNNNC0
B9P6C3AYNNNC0
B015C3AYNANC0
B022C3AYNANC0
B028C3AYNANC0
B042C3AYNANC0
B054C3AYNANC0
B070C3AYNANC0
B
B
B
B
D
D
D
D
E
E
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
11
15
0.33
0.75
1.5
2.0
3.0
5.0
7.5
10
15
20
380-480V ac, Three-Phase Drives (For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
Output Amps
480V ac Input ➊
Cont.
1 Min.
1.1
2.1
3.4
5.0
8.0
11
14
22
27
34
40
52
65
1.2
2.4
4.5
5.5
8.8
12.1
16.5
24.2
33
40.5
51
60
78
3 Sec.
Nominal Power Ratings
Normal Duty
Heavy Duty
kW
Hp
kW
Hp
IP66, NEMA Type 4X/12 with HIM
380-400V ac Input
Cont.
1 Min. 3 Sec.
Catalog Number
20A…
Frame
Size
1.6
3.2
6.0
7.5
12
16.5
22
33
44
54
68
80
104
1.3
2.1
3.5
5.0
8.7
11.5
15.4
22
30
37
43
60
72
0.37
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
D1P1C3AYNNNC0
D2P1C3AYNNNC0
D3P4C3AYNNNC0
D5P0C3AYNNNC0
D8P0C3AYNNNC0
D011C3AYNANC0
D014C3AYNANC0
D022C3AYNANC0
D027C3AYNANC0
D034C3AYNANC0
D040C3AYNANC0
D052C3AYNANC0 ➋
D065C3AYNANC0 ➋
B
B
B
B
B
D
D
D
D
D
D
E
E
1.4
2.4
4.5
5.5
9.9
13
17.2
24.2
33
45
56
66
90
1.9
3.2
6.0
7.5
13.2
17.4
23.1
33
45
60
74
90
120
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
11
15
18.5
22
30
0.33
0.75
1.5
2.0
3.0
5.0
7.5
10
15
20
25
30
40
500-600V ac, Three-Phase Drives (For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
Output Amps
600V ac Input
Cont.
1 Min.
0.9
1.7
2.7
3.9
6.1
9.0
11
17
22
27
32
41
52
1.0
1.9
3.6
4.3
6.7
9.9
13.5
18.7
25.5
33
40.5
48
61.5
3 Sec.
Nominal Power Ratings
Normal Duty
kW
Hp
Heavy Duty
kW
Hp
Catalog Number
20A…
Frame
Size
1.4
2.6
4.8
5.8
9.1
13.5
18
25.5
34
44
54
64
82
0.37
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
11
15
18.5
22
30
E0P9C3AYNNNC0
E1P7C3AYNNNC0
E2P7C3AYNNNC0
E3P9C3AYNNNC0
E6P1C3AYNNNC0
E9P0C3AYNNNC0
E011C3AYNNNC0
E017C3AYNNNC0
E022C3AYNNNC0
E027C3AYNNNC0
E032C3AYNNNC0
E041C3AYNANC0
E052C3AYNANC0
B
B
B
B
B
D
D
D
D
D
D
E
E
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
IP66/NEMA Type 4X/12 with HIM
0.33
0.75
1.0
1.5
3.0
5.0
7.5
10
15
20
25
30
40
➊ Catalog code corresponds to output amps in these columns. Drive must be programmed to lower voltage to obtain higher currents shown at right.
➋ Frame E ratings are only available with Enhanced Control.
9
Product Selection Guide
PowerFlex 70 Drives — Wall / Machine Mount - IP 54, NEMA Type 12
200-240V ac, Three-Phase Drives (For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
Output Amps
240V ac Input ➊
Cont.
1 Min.
54
70
63
81
3 Sec.
208V ac Input
Cont.
1 Min.
84
108
62.1
78.2
72.4
93.1
IP66, NEMA Type 4X/12 with HIM
3 Sec.
Nominal Power Ratings
Normal Duty
Heavy Duty
kW
Hp
kW
Hp
Catalog Number
20A…
Frame
Size
96.6
124
15
18.5
B054G3AYNANC0
B070G3AYNANC0
E
E
20
25
11
15
15
20
380-480V ac, Three-Phase Drives (For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
Output Amps
480V ac Input ➊
Cont.
1 Min.
52
65
60
78
3 Sec.
Nominal Power Ratings
Normal Duty
Heavy Duty
kW
Hp
kW
Hp
IP66, NEMA Type 4X/12 with HIM
380-400V ac Input
Cont.
1 Min. 3 Sec.
Catalog Number
20A…
Frame
Size
80
104
60
72
30
37
D052G3AYNANC0
D065G3AYNANC0
E
E
66
90
90
120
40
50
22
30
30
40
500-600V ac, Three-Phase Drives (For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
Output Amps
600V ac Input ➊
Cont.
1 Min.
41
52
10
48
61.5
3 Sec.
Nominal Power Ratings
Normal Duty
Heavy Duty
kW
Hp
kW
Hp
IP66, NEMA Type 4X/12 with HIM
500-600V ac Input
Cont.
1 Min. 3 Sec.
Catalog Number
20A…
Frame
Size
64
82
41
52
30
37
E041G3AYNANC0
E052G3AYNANC0
E
E
48
61.5
64
82
40
50
22
30
30
40
Product Selection Guide
PowerFlex 70 Drives — Flange Mount ➊ - Front Chassis = IP 20, NEMA Type 1; Heatsink = IP 66, NEMA
Type 4X/12
200-240V ac, Three-Phase Drives
Output Amps
240V ac Input þ
Cont.
1 Min.
2.2
4.2
6.8
9.6
15.3
22
28
42
54
70
2.4
4.8
9.0
10.6
17.4
24.2
33
46.2
63
81
(For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
3 Sec.
208V ac Input
Cont.
1 Min.
3.3
6.4
12
14.4
23.2
33
44
63
84
108
2.5
4.8
7.8
11
17.5
25.3
32.2
43
62.1
78.2
2.7
5.5
10.3
12.1
19.2
27.8
37.9
55.5
72.4
93.1
Flange Type with HIM
3 Sec.
Nominal Power Ratings
Normal Duty
Heavy Duty
kW
Hp
kW
Hp
Catalog Number
20A…
Frame
Size
3.7
7.4
13.8
16.5
26.2
37.9
50.6
74
96.6
124
0.37
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
B2P2F3AYNNNC0
B4P2F3AYNNNC0
B6P8F3AYNNNC0
B9P6F3AYNNNC0
B015F3AYNANC0
B022F3AYNANC0
B028F3AYNANC0
B042F3AYNANC0
B054F3AYNANC0
B070F3AYNANC0
A
A
B
B
C
D
D
D
E
E
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
11
15
0.33
0.75
1.5
2.0
3.0
5.0
7.5
10
15
20
380-480V ac, Three-Phase Drives (For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
Output Amps
480V ac Input ➋
Cont.
1 Min.
1.1
2.1
3.4
5.0
8.0
11
14
22
27
34
40
52
65
1.2
2.4
4.5
5.5
8.8
12.1
16.5
24.2
33
40.5
51
60
78
3 Sec.
Nominal Power Ratings
Normal Duty
Heavy Duty
kW
Hp
kW
Hp
Flange Type with HIM
380-400V ac Input
Cont.
1 Min. 3 Sec.
Catalog Number
20A…
Frame
Size
1.6
3.2
6.0
7.5
12
16.5
22
33
44
54
68
80
104
1.3
2.1
3.5
5.0
8.7
11.5
15.4
22
30
37
43
60
72
0.37
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
D1P1F3AYNNNC0
D2P1F3AYNNNC0
D3P4F3AYNNNC0
D5P0F3AYNNNC0
D8P0F3AYNNNC0
D011F3AYNANC0
D014F3AYNANC0
D022F3AYNANC0
D027F3AYNANC0
D034F34YNANC0
D040F3AYNANC0
D052F3AYNANC0
D065F3AYNANC0
A
A
A
B
B
C
C
D
D
D
D
E
E
1.4
2.4
4.5
5.5
9.9
13
17.2
24.2
33
45
56
66
90
1.9
3.2
6.0
7.5
13.2
17.4
23.1
33
45
60
74
90
120
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
11
15
18.5
22
30
0.33
0.75
1.5
2.0
3.0
5.0
7.5
10
15
20
25
30
40
500-600V ac, Three-Phase Drives (For pricing information, refer to the PowerFlex 70 Price List, Publication 20A-PL001…)
Output Amps
600V ac Input
Cont.
1 Min.
0.9
1.7
2.7
3.9
6.1
9.0
11
17
22
27
32
41
52
1.0
1.9
3.6
4.3
6.7
9.9
13.5
18.7
25.5
33
40.5
48
61.5
3 Sec.
Nominal Power Ratings
Normal Duty
kW
Hp
Heavy Duty
kW
Hp
Catalog Number
20A…
Frame Size
1.4
2.6
4.8
5.8
9.1
13.5
18
25.5
34
44
54
64
82
0.37
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
11
15
18.5
22
30
E0P9F3AYNNNC0
E1P7F3AYNNNC0
E2P7F3AYNNNC0
E3P9F3AYNNNC0
E6P1F3AYNNNC0
E9P0F3AYNNNC0
E011F3AYNNNC0
E017F3AYNNNC0
E022F3AYNNNC0
E027F3AYNNNC0
E032F3AYNNNC0
E041F3AYNANC0
E052F3AYNANC0
A
A
A
B
B
C
C
D
D
D
D
E
E
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
Flange Type with HIM
0.33
0.75
1.0
1.5
3.0
5.0
7.5
10
15
20
25
30
40
➊ Provides a method for heatsink to be external to customer enclosure. Front chassis = IP20, NEMA Type 1; Rear Heatsink = IP66 UL Type 4X/12 for indoor/outdoor use.
➋ Catalog code corresponds to output amps in these columns. Drive must be programmed to lower voltage to obtain higher currents shown at right.
11
Product Selection Guide
Accessories
HIM (Blank Plate)
20-HIM-A0
Cat Code: 0
LCD Digital Speed
20-HIM-A2
Cat Code: 2
Remote (Panel Mount)
Full Numeric
20-HIM-C3
20-HIM-C3S
LCD Full Numeric
20-HIM-A3
Cat Code: 3
LCD Programmer Only
20-HIM-A5
Cat Code: 5
Remote (Panel Mount)
Programmer Only
20-HIM-C5S
20-HIM-C5
DPI NEMA 1 WIM
20-WIM-N1
Cat Code: 8
LCD NEMA 4X/12 ➋
No HIM (Blank)
Cat Code: 0
DPI NEMA 4 WIM
Remote (Panel Mount)
Cat Code: 8
LCD NEMA 4X/12 ➋
Full Numeric
Cat Code: 3
LCD NEMA 4X/12 ➋
Programmer Only
Cat Code: 5
Human Interface Modules (HIM) Option Kits
Catalog Number
Handheld/Local (Drive Mount) Type ➊
User Installed
Factory Installed
(position 9)
Blank Plate ➋
LCD Display, Digital Speed
LCD Display, Full Numeric Keypad ➋
LCD Display, Programmer Only ➋
DPI NEMA 1 WIM
20-HIM-A0
0
20-HIM-A2
2
20-HIM-A3
3
20-HIM-A5
5
20-WIM-N1
8
Remote (Panel Mount) IP 66, UL Type 4x/12 ➌
LCD Display, Full Numeric Keypad
20-HIM-C3 ➍
–
20-HIM-C3S ➎
–
LCD Display, Programmer Only
20-HIM-C5 ➍
–
20-HIM-C5S ➎
–
DPI NEMA 4 WIM
20-WIM-N4S
–
➊ Mounts to either IP20, NEMA Type 1 or Flange Type.
➋ Available only as factory installed for IP66, NEMA Type 4X/12 and IP54, NEMA Type 12 drives.
➌ For indoor use only.
➍ Includes a 1 meter PowerFlex HIM Interface Cable (20-HIM-H10).
➎ Includes a 3 meter 1202-C30 cable.
Human Interface Module/Communication Interface Cables
Description
Catalog No.
Description
Catalog No.
Bezel Kit for LCD HIMs, NEMA 1 ➏
PowerFlex HIM Interface Cable, 1 m (39 in.)➐
HIM/Comm Cable Kit (Male-Female) ➑
0.33 Meters (1.1 Feet)
1 Meter (3.3 Feet)
3 Meter (9.8 Feet)
9 Meter (29.5 Feet)
20-HIM-B1
20-HIM-H10
DPI Cable Kit with Connectors, Tools and 100 m (328 ft.) Cable
DPI Cable Connector Kit
Comm Option Cable Kit
0.33 Meters (1.1 Feet)
1 Meter (3.3 Feet)
3 Meter (9.8 Feet)
9 Meter (29.5 Feet)
DPI/SCANport One to Two Port Splitter Cable
1202-CBL-KIT-100M
1202-TB-KIT-SET
1202-H03
1202-H10
1202-H30
1202-H90
➏Includes an interface cable (1202-C30) for connection to drive.
➐ Required only when HIM is used as handheld or remotely mounted.
➑ Required in addition to 20-HIM-H10 for distances up to 100 Meters (328 Feet) maximum.
12
1202-C03
1202-C10
1202-C30
1202-C90
1203-S03
Product Selection Guide
Accessories, Continued
EMC Filters
Catalog Number
Description
Frame
User Installed
Factory Installed
(Position 13)
External 1-Phase 200-240V, 8A Filter
External 3-Phase 200-480V, 5A Filter
Internal 3-Phase 200-480 Filter➊
A
A
B, C, D
20A-RF-08-A1
20A-RF-05-A3
–
N/A
N/A
A
➊ Standard on Frames C and D. Optional on Frame B (Frame A ratings increase to Frame B).
EMC Filter
20A-RF-08-A1
20A-RF-05-A3
Communication Options
Description
ControlNet Communication Adapter (Coax)
DeviceNet Communication Adapter
EtherNet/IP Communication Adapter
RS485 HVAC Communication Adapter
(Modbus RTU, Metasys N2, Siemens P1)
Interbus Communication Adapter
LonWorks Communication Adapter
PROFIBUS DP Communication Adapter
ControlNet Communication Adapter (Fiber)
Remote I/O Communication Adapter
RS485 DF-1 Communication Adapter
External DPI Communications Kit for 20-COMM-C, -D, -E
and -Q adapters. Multi-Drive capability allows connectivity
for up to 5 drives.
External DPI I/O Option Board
External Comms Power Supply. Optional 100-240V ac power
supply for external DPI communications kits.
Compact I/O Module (3 Channel)
Smart Self-powered Serial Converter (RS-232)
includes 1203-SFC and 1202-C10 Cables
Serial Null Modem Adapter
Catalog No. User
Installed
Factory
Installed
(Position 14)
20-COMM-C
20-COMM-D
20-COMM-E
20-COMM-H
C
D
E
H
20-COMM-I
20-COMM-L
20-COMM-P
20-COMM-Q
20-COMM-R
20-COMM-S
20-XCOMM-DC-BASE
N/A
N/A
N/A
N/A
R
S
N/A
20-XCOMM-IO-OPT1
20-XCOMM-AC-PS1
N/A
N/A
1769-SM1
1203-SSS
N/A
N/A
1203-SNM
N/A
Communication
Adapter
20-COMM-D
Other Options
Catalog No.
Description
User Installed
Factory Installed
(Position 15) (Position 16)
DriveGuard™ Safe-Off Board ➋
Service Connection Board ➌
5V/12V Encoder Option Board
115 Volt AC Interface Card
Frame E Flange Gasket
20A-DG01
SK-M9-SCB1
20A-ENC-1
AK-M9-115VAC-1
AK-M9-GASKET1-E4
G
N/A
N/A
N/A
N/A
N/A
N/A
1
N/A
N/A
➋ Works only with PowerFlex 70 Enhanced Control.
DriveGuard™ Safe-Off Option
20A-DG01
Cat Code: G
Service Connection Board
SK-M9-SCB1
1
2
3
4
5
9
8
7
6
5
4
3
2
1
➌ Provides temporary DPI/HIM connection for NEMA 1 and Flange drives with cover removed.
6
5V/12V Encoder Option Board
20A-ENC-1
Cat Code: 1
115V Interface Card
AK-M9-115VAC-1
13
Product Selection Guide
Accessories, Continued
Dynamic Brake Resistors
Application requirements should be thoroughly evaluated to determine what size (and thus type) will be sufficient. Publication PFLEX-AT001…,
Dynamic Braking Resistor Calculator, provides a method based on application data such as load inertia.
Small Duty Internal DB Resistors
Limited duty resistors mount directly to the back surface of the drive and require no extra panel space. Internal resistors are non-destructive and do not
require a resistor overheat external safety circuit.
PowerFlex 70 AC Drive
Normal
Duty
Heavy Duty Min DB Res
kW (Hp)
kW (Hp)
Ohms ±10%
200-240 Volt AC Input Drives
0.37 (0.5) 0.25 (0.33)
33
0.75 (1.0) 0.55 (0.75)
33
1.5 (2.0)
1.1 (1.5)
33
2.2 (3.0)
1.5 (2.0)
33
4.0 (5.0)
3.0 (3.0)
30
5.5 (7.5)
4.0 (5.0)
23
7.5 (10)
5.5 (7.5)
23
400-480 Volt AC Input Drives
0.37 (0.5) 0.25 (0.33)
68
0.75 (1.0) 0.55 (0.75)
68
1.5 (2.0)
1.1 (1.5)
68
2.2 (3.0)
1.5 (2.0)
68
4.0 (5.0)
3.0 (3.0)
68
5.5 (7.5)
4.0 (5.0)
74
7.5 (10)
5.5 (7.5)
74
11 (15)
7.5 (10)
44
15 (20)
11 (15)
31
500-600 Volt AC Input Drives
0.37 (0.5) 0.25 (0.33)
117
0.75 (1.0) 0.55 (0.75)
117
1.5 (2.0)
1.1 (1.5)
117
2.2 (3.0)
1.5 (2.0)
117
4.0 (5.0)
3.0 (3.0)
80
5.5 (7.5)
4.0 (5.0)
80
7.5 (10)
5.5 (7.5)
80
11 (15)
7.5 (10)
48
15 (20)
11 (15)
48
Small Duty Internal DB Resistor
Application Type 1
Max Braking
Max
Braking Torque
Energy Torque
% of ND Motor % of ND Motor Duty Cycle
kJ
Application Type 2
Braking Torque
% of ND Motor Duty Cycle
Resistance
Ohms ±5%
Continuos
Power
kW
20AB-DB1-A
20AB-DB1-A
20AB-DB1-B
20AB-DB1-B
20AB-DB1-C
20AB-DB1-D
20AB-DB1-D
62
62
62
62
62
22
22
0.048
0.048
0.028
0.028
0.040
0.036
0.036
8.3
7.3
0.8
0.8
0.8
0.9
0.9
307%
300%
160%
109%
60%
117%
86%
100%
100%
100%
100%
60%
100%
86%
25.9%
12.8%
3.7%
2.5%
3.3%
1.3%
1.1%
150%
150%
150%
109%
N/A
117%
N/A
17.3%
8.5%
2.5%
2.3%
N/A
1.1%
N/A
20AD-DB1-A
20AD-DB1-A
20AD-DB1-A
20AD-DB1-B
20AD-DB1-B
20AD-DB1-C
20AD-DB1-C
20AD-DB1-D
20AD-DB1-D
115
115
115
115
115
115
115
62
62
0.048
0.048
0.048
0.028
0.028
0.04
0.04
0.036
0.036
8.3
9.0
2.4
0.9
0.9
0.9
0.9
0.8
0.8
320%
259%
243%
206%
129%
94%
69%
87%
64%
100%
100%
100%
100%
100%
94%
69%
87%
64%
25.9%
12.8%
6.4%
2.5%
1.4%
1.5%
1.5%
0.8%
0.8%
150%
150%
150%
150%
129%
N/A
N/A
N/A
N/A
17.3%
8.5%
4.3%
1.7%
1.1%
N/A
N/A
N/A
N/A
20AD-DB1-A
20AD-DB1-A
20AD-DB1-A
20AD-DB1-B
20AD-DB1-B
20AD-DB1-C
20AD-DB1-C
N/A
N/A
115
115
115
115
115
115
115
N/A
N/A
0.048
0.048
0.048
0.028
0.028
0.04
0.04
N/A
N/A
8.3
9.0
2.4
0.9
0.9
0.9
0.9
N/A
N/A
287%
263%
243%
202%
193%
147%
108%
N/A
N/A
100%
100%
100%
100%
100%
100%
100%
N/A
N/A
25.9%
12.8%
6.4%
2.5%
1.4%
1.5%
1.1%
N/A
N/A
150%
150%
150%
150%
150%
147%
108%
N/A
N/A
17.3%
8.5%
4.3%
1.7%
0.9%
1.0%
1.0%
N/A
N/A
Part Number
Medium Duty External DB Resistors
These resistors provide a larger duty cycle capability than the internal type. Includes an internal thermal switch for use in external safety circuit.
PowerFlex 70 AC Drive
Normal
Duty
Heavy Duty Min DB Res
kW (Hp)
kW (Hp)
Ohms ±10%
200-240 Volt AC Input Drives
0.37 (0.5) 0.25 (0.33)
33
0.75 (1.0) 0.55 (0.75)
33
1.5 (2.0)
1.1 (1.5)
33
2.2 (3.0)
1.5 (2.0)
33
4.0 (5.0)
3.0 (3.0)
30
5.5 (7.5)
4.0 (5.0)
23
7.5 (10)
5.5 (7.5)
23
400-480 Volt AC Input Drives
0.37 (0.5) 0.25 (0.33)
68
0.75 (1.0) 0.55 (0.75)
68
1.5 (2.0)
1.1 (1.5)
68
2.2 (3.0)
1.5 (2.0)
68
4.0 (5.0)
3.0 (3.0)
68
5.5 (7.5)
4.0 (5.0)
74
7.5 (10)
5.5 (7.5)
74
11 (15)
7.5 (10)
44
15 (20)
11 (15)
31
500-600 Volt AC Input Drives
0.37 (0.5) 0.25 (0.33)
117
0.75 (1.0) 0.55 (0.75)
117
1.5 (2.0)
1.1 (1.5)
117
2.2 (3.0)
1.5 (2.0)
117
4.0 (5.0)
3.0 (3.0)
80
5.5 (7.5)
4.0 (5.0)
80
7.5 (10)
5.5 (7.5)
80
11 (15)
7.5 (10)
48
15 (20)
11 (15)
48
Note 1:
Note 2:
Note 3:
14
Part Number
Resistance
Ohms ±5%
Continuos
Power
kW
Medium Duty External DB Resistor
Application Type 1
Max
Max Braking
Energy Torque
Braking Torque
kJ
% of ND Motor % of ND Motor Duty Cycle
Application Type 2
Braking Torque
% of ND Motor Duty Cycle
AK-R2-091P500
AK-R2-091P500
AK-R2-091P500
AK-R2-047P500
AK-R2-047P500
AK-R2-030P1K2
AK-R2-030P1K2
91
91
91
47
47
30
30
0.086
0.086
0.086
0.166
0.166
0.26
0.26
17
17
17
33
33
52
52
293%
218%
109%
144%
79%
90%
66%
100%
100%
100%
100%
79%
90%
66%
46%
23%
11%
15%
11%
10%
10%
150%
150%
109%
144%
N/A
N/A
N/A
31%
15%
11%
11%
N/A
N/A
N/A
AK-R2-360P500
AK-R2-360P500
AK-R2-360P500
AK-R2-120P1K2
AK-R2-120P1K2
AK-R2-120P1K2
AK-R2-120P1K2
See Note 3
See Note 3
360
360
360
120
120
120
120
60
60
0.086
0.086
0.086
0.26
0.26
0.26
0.26
0.52
0.52
17
17
17
52
52
52
52
104
104
305%
220%
110%
197%
124%
90%
66%
90%
66%
100%
100%
100%
100%
100%
90%
66%
90%
66%
47%
23%
12%
24%
13%
10%
10%
10%
10%
150%
150%
110%
150%
124%
N/A
N/A
N/A
N/A
31%
15%
11%
16%
10%
N/A
N/A
N/A
N/A
AK-R2-360P500
AK-R2-360P500
AK-R2-360P500
AK-R2-120P1K2
AK-R2-120P1K2
AK-R2-120P1K2
AK-R2-120P1K2
See Note 3
See Note 3
360
360
360
120
120
120
120
60
60
0.086
0.086
0.086
0.26
0.26
0.26
0.26
0.52
0.52
17
17
17
52
52
52
52
104
104
274%
251%
172%
193%
185%
141%
103%
141%
103%
100%
100%
100%
100%
100%
100%
100%
100%
100%
46%
23%
11%
24%
13%
9%
7%
9%
7%
150%
150%
150%
150%
150%
141%
103%
141%
103%
31%
15%
8%
16%
9%
7%
7%
7%
7%
Always check resistor ohms against minimum resistance for drive being used.
Duty cycle listed is based on full speed to zero speed deceleration.
For constant regen at full speed, duty cycle capability is half of what is listed.
Application Type 1 represents maximum capability up to 100% braking torque where possible.
Application Type 2 represents more than 100% braking torque where possible, up to a maximum of 150%.
For 11 and 15 kW (15 and 20 Hp) applications, use two 7.5 kW (10 Hp) size resistors wired in parallel.
Product Selection Guide
Accessories, Continued
Input and Output Line Reactors – 240V, 60 Hz, Three-Phase
Input Line Reactor➊
Drive Catalog
Number
Duty
Hp
Output Line Reactor➊
IP 00 (Open Style)
IP 11 (Nema Type 1)
IP 00 (Open Style)
IP 11 (Nema Type 1)
Catalog Number
Catalog Number
Catalog Number
Catalog Number
1321-3R2-D
1321-3R2-D
1321-3R4-A
1321-3R4-A
1321-3R8-A
1321-3R8-A
1321-3R8-A
1321-3R12-A
1321-3R12-A
1321-3R18-A
1321-3R18-A
1321-3R25-A
1321-3R25-A
1321-3R35-A
1321-3R35-A
1321-3R45-A
1321-3R45-A
1321-3R55-A
1321-3R55-A
1321-3R80-A
1321-3RA2-D
1321-3RA2-D
1321-3RA4-A
1321-3RA4-A
1321-3RA8-A
1321-3RA8-A
1321-3RA8-A
1321-3RA12-A
1321-3RA12-A
1321-3RA18-A
1321-3RA18-A
1321-3RA25-A
1321-3RA25-A
1321-3RA35-A
1321-3RA35-A
1321-3RA45-A
1321-3RA45-A
1321-3RA55-A
1321-3RA55-A
1321-3RA80-A
1321-3R2-D
1321-3R2-D
1321-3R4-A
1321-3R4-A
1321-3R8-A
1321-3R8-A
1321-3R12-A
1321-3R12-A
1321-3R18-A
1321-3R18-A
1321-3R25-A
1321-3R25-A
1321-3R35-A
1321-3R35-A
1321-3R45-A
1321-3R45-A
1321-3R55-A
1321-3R55-A
1321-3R80-A
1321-3R80-A
1321-3RA2-D
1321-3RA2-D
1321-3RA4-A
1321-3RA4-A
1321-3RA8-A
1321-3RA8-A
1321-3RA12-A
1321-3RA12-A
1321-3RA18-A
1321-3RA18-A
1321-3RA25-A
1321-3RA25-A
1321-3RA35-A
1321-3RA35-A
1321-3RA45-A
1321-3RA45-A
1321-3RA55-A
1321-3RA55-A
1321-3RA80-A
1321-3RA80-A
1321-3R2-A
1321-3R2-A
1321-3R4-B
1321-3R4-B
1321-3R8-B
1321-3R8-B
1321-3R8-B
1321-3R12-B
1321-3R12-B
1321-3R18-B
1321-3R18-B
1321-3R25-B
1321-3R25-B
1321-3R35-B
1321-3R35-B
1321-3R45-B
1321-3R45-B
1321-3R55-B
1321-3R55-B
1321-3R80-B
1321-3RA2-A
1321-3RA2-A
1321-3RA4-B
1321-3RA4-B
1321-3RA8-B
1321-3RA8-B
1321-3RA8-B
1321-3RA12-B
1321-3RA12-B
1321-3RA18-B
1321-3RA18-B
1321-3RA25-B
1321-3RA25-B
1321-3RA35-B
1321-3RA35-B
1321-3RA45-B
1321-3RA45-B
1321-3RA55-B
1321-3RA55-B
1321-3RA80-B
1321-3R2-A
1321-3R2-A
1321-3R4-B
1321-3R4-B
1321-3R8-B
1321-3R8-B
1321-3R12-B
1321-3R12-B
1321-3R18-B
1321-3R18-B
1321-3R25-B
1321-3R25-B
1321-3R35-B
1321-3R35-B
1321-3R45-B
1321-3R45-B
1321-3R55-B
1321-3R55-B
1321-3R80-B
1321-3R80-B
1321-3RA2-A
1321-3RA2-A
1321-3RA4-B
1321-3RA4-B
1321-3RA8-B
1321-3RA8-B
1321-3RA12-B
1321-3RA12-B
1321-3RA18-B
1321-3RA18-B
1321-3RA25-B
1321-3RA25-B
1321-3RA35-B
1321-3RA35-B
1321-3RA45-B
1321-3RA45-B
1321-3RA55-B
1321-3RA55-B
1321-3RA80-B
1321-3RA80-B
3% Impedance – 240V, 60 Hz, Three-Phase
20AB2P2
20AB2P2
20AB4P2
20AB4P2
20AB6P8
20AB6P8
20AB9P6
20AB9P6
20AB015
20AB015
20AB022
20AB022
20AB028
20AB028
20AB042
20AB042
20AB054
20AB054
20AB070
20AB070
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
0.33
0.5
0.75
1.0
1.5
2.0
2.0
3.0
3.0
5.0
5.0
7.5
7.5
10
10
15
15
20
20
25
5% Impedance – 240V, 60 Hz, Three-Phase
20AB2P2
20AB2P2
20AB4P2
20AB4P2
20AB6P8
20AB6P8
20AB9P6
20AB9P6
20AB015
20AB015
20AB022
20AB022
20AB028
20AB028
20AB042
20AB042
20AB054
20AB054
20AB070
20AB070
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
Heavy Duty
Normal Duty
0.33
0.5
0.75
1.0
1.5
2.0
2.0
3.0
3.0
5.0
5.0
7.5
7.5
10
10
15
15
20
20
25
➊ Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.
15
Product Selection Guide
Accessories, Continued
Input and Output Line Reactors – 480V, 60 Hz, Three-Phase
Input Line Reactor➊
Drive Catalog
Number
Duty
Hp
3% Impedance – 480V, 60 Hz, Three-Phase
20AD1P1
Heavy Duty
0.33
20AD1P1
Normal Duty
0.5
20AD2P1
Heavy Duty
0.75
20AD2P1
Normal Duty
1.0
20AD3P4
Heavy Duty
1.5
20AD3P4
Normal Duty
2.0
20AD5P0
Heavy Duty
2.0
20AD5P0
Normal Duty
3.0
20AD8P0
Heavy Duty
3.0
20AD8P0
Normal Duty
5.0
20AD011
Heavy Duty
5.0
20AD011
Normal Duty
7.5
20AD014
Heavy Duty
7.5
20AD014
Normal Duty
10
20AD022
Heavy Duty
10
20AD022
Normal Duty
15
20AD027
Heavy Duty
15
20AD027
Normal Duty
20
20AD034
Heavy Duty
20
20AD034
Normal Duty
25
20AD040
Heavy Duty
25
20AD040
Normal Duty
30
20AD052
Heavy Duty
30
20AD052
Normal Duty
40
20AD065
Heavy Duty
40
20AD065
Normal Duty
50
5% Impedance – 480V, 60 Hz, Three-Phase
20AD1P1
Heavy Duty
0.33
20AD1P1
Normal Duty
0.5
20AD2P1
Heavy Duty
0.75
20AD2P1
Normal Duty
1.0
20AD3P4
Heavy Duty
1.5
20AD3P4
Normal Duty
2.0
20AD5P0
Heavy Duty
2.0
20AD5P0
Normal Duty
3.0
20AD8P0
Heavy Duty
3.0
20AD8P0
Normal Duty
5.0
20AD011
Heavy Duty
5.0
20AD011
Normal Duty
7.5
20AD014
Heavy Duty
7.5
20AD014
Normal Duty
10
20AD022
Heavy Duty
10
20AD022
Normal Duty
15
20AD027
Heavy Duty
15
20AD027
Normal Duty
20
20AD034
Heavy Duty
20
20AD034
Normal Duty
25
20AD040
Heavy Duty
25
20AD040
Normal Duty
30
20AD052
Heavy Duty
30
20AD052
Normal Duty
40
20AD065
Heavy Duty
40
20AD065
Normal Duty
50
Output Line Reactor➊
IP 00 (Open Style)
IP 11 (Nema Type 1)
IP 00 (Open Style)
IP 11 (Nema Type 1)
Catalog Number
Catalog Number
Catalog Number
Catalog Number
1321-3R1-C
1321-3R1-C
1321-3R2-A
1321-3R2-A
1321-3R4-C
1321-3R4-B
1321-3R4-B
1321-3R8-C
1321-3R8-C
1321-3R8-B
1321-3R8-B
1321-3R12-B
1321-3R12-B
1321-3R18-B
1321-3R18-B
1321-3R25-B
1321-3R25-B
1321-3R35-B
1321-3R35-B
1321-3R35-B
1321-3R35-B
1321-3R45-B
1321-3R45-B
1321-3R55-B
1321-3R55-B
1321-3R80-B
1321-3RA1-C
1321-3RA1-C
1321-3RA2-A
1321-3RA2-A
1321-3RA4-C
1321-3RA4-B
1321-3RA4-B
1321-3RA8-C
1321-3RA8-C
1321-3RA8-B
1321-3RA8-B
1321-3RA12-B
1321-3RA12-B
1321-3RA18-B
1321-3RA18-B
1321-3RA25-B
1321-3RA25-B
1321-3RA35-B
1321-3RA35-B
1321-3RA35-B
1321-3RA35-B
1321-3RA45-B
1321-3RA45-B
1321-3RA55-B
1321-3RA55-B
1321-3RA80-B
1321-3R2-B
1321-3R2-B
1321-3R2-A
1321-3R2-A
1321-3R4-B
1321-3R4-B
1321-3R8-C
1321-3R8-C
1321-3R8-B
1321-3R8-B
1321-3R12-B
1321-3R12-B
1321-3R18-B
1321-3R18-B
1321-3R25-B
1321-3R25-B
1321-3R25-B
1321-3R25-B
1321-3R35-B
1321-3R35-B
1321-3R45-B
1321-3R45-B
1321-3R55-B
1321-3R55-B
1321-3R80-B
1321-3R80-B
1321-3RA2-B
1321-3RA2-B
1321-3RA2-A
1321-3RA2-A
1321-3RA4-B
1321-3RA4-B
1321-3RA8-C
1321-3RA8-C
1321-3RA8-B
1321-3RA8-B
1321-3RA12-B
1321-3RA12-B
1321-3RA18-B
1321-3RA18-B
1321-3RA25-B
1321-3RA25-B
1321-3RA25-B
1321-3RA25-B
1321-3RA35-B
1321-3RA35-B
1321-3RA45-B
1321-3RA45-B
1321-3RA55-B
1321-3RA55-B
1321-3RA80-B
1321-3RA80-B
1321-3R1-B
1321-3R1-B
1321-3R2-C
1321-3R2-B
1321-3R4-D
1321-3R4-D
1321-3R4-D
1321-3R8-D
1321-3R8-D
1321-3R8-C
1321-3R8-C
1321-3R12-C
1321-3R12-C
1321-3R18-C
1321-3R18-C
1321-3R25-C
1321-3R25-C
1321-3R35-C ➋
1321-3R35-C ➋
1321-3R35-C
1321-3R35-C
1321-3R45-C
1321-3R45-C
1321-3R55-C
1321-3R55-C
1321-3R80-C
1321-3RA1-B
1321-3RA1-B
1321-3RA2-C
1321-3RA2-B
1321-3RA4-D
1321-3RA4-D
1321-3RA4-D
1321-3RA8-D
1321-3RA8-D
1321-3RA8-C
1321-3RA8-C
1321-3RA12-C
1321-3RA12-C
1321-3RA18-C
1321-3RA18-C
1321-3RA25-C
1321-3RA25-C
1321-3RA35-C ➋
1321-3RA35-C ➋
1321-3RA35-C
1321-3RA35-C
1321-3RA45-C
1321-3RA45-C
1321-3RA55-C
1321-3RA55-C
1321-3RA80-C
1321-3R2-C
1321-3R2-C
1321-3R2-B
1321-3R2-B
1321-3R4-D
1321-3R4-D
1321-3R8-D
1321-3R8-D
1321-3R8-C
1321-3R8-C
1321-3R12-C
1321-3R12-C
1321-3R18-C
1321-3R18-C
1321-3R25-C
1321-3R25-C
1321-3R25-C
1321-3R25-C
1321-3R35-C
1321-3R35-C
1321-3R45-C
1321-3R45-C
1321-3R55-C
1321-3R55-C
1321-3R80-C
1321-3R80-C
1321-3RA2-C
1321-3RA2-C
1321-3RA2-B
1321-3RA2-B
1321-3RA4-D
1321-3RA4-D
1321-3RA8-D
1321-3RA8-D
1321-3RA8-C
1321-3RA8-C
1321-3RA12-C
1321-3RA12-C
1321-3RA18-C
1321-3RA18-C
1321-3RA25-C
1321-3RA25-C
1321-3RA25-C
1321-3RA25-C
1321-3RA35-C
1321-3RA35-C
1321-3RA45-C
1321-3RA45-C
1321-3RA55-C
1321-3RA55-C
1321-3RA80-C
1321-3RA80-C
➊ Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.
➋ Reactors sized at 4% impedance.
16
Product Selection Guide
Accessories, Continued
Input and Output Line Reactors – 600V, 60 Hz, Three-Phase
Input Line Reactor➊
Drive Catalog
Number
Duty
Hp
3% Impedance – 480V, 60 Hz, Three-Phase
20AE0P9
Heavy Duty
0.33
20AE0P9
Normal Duty
0.5
20AE1P7
Heavy Duty
0.75
20AE1P7
Normal Duty
1.0
20AE2P7
Heavy Duty
1.5
20AE2P7
Normal Duty
2.0
20AE3P9
Heavy Duty
2.0
20AE3P9
Normal Duty
3.0
20AE6P1
Heavy Duty
3.0
20AE6P1
Normal Duty
5.0
20AE9P0
Heavy Duty
5.0
20AE9P0
Normal Duty
7.5
20AE011
Heavy Duty
7.5
20AE011
Normal Duty
10
20AE017
Heavy Duty
10
20AE017
Normal Duty
15
20AE022
Heavy Duty
15
20AE022
Normal Duty
20
20AE027
Heavy Duty
20
20AE027
Normal Duty
25
20AE032
Heavy Duty
25
20AE032
Normal Duty
30
20AE041
Heavy Duty
30
20AE041
Normal Duty
40
20AE052
Heavy Duty
40
20AE052
Normal Duty
50
5% Impedance – 480V, 60 Hz, Three-Phase
20AE0P9
Heavy Duty
0.33
20AE0P9
Normal Duty
0.5
20AE1P7
Heavy Duty
0.75
20AE1P7
Normal Duty
1.0
20AE2P7
Heavy Duty
1.5
20AE2P7
Normal Duty
2.0
20AE3P9
Heavy Duty
2.0
20AE3P9
Normal Duty
3.0
20AE6P1
Heavy Duty
3.0
20AE6P1
Normal Duty
5.0
20AE9P0
Heavy Duty
5.0
20AE9P0
Normal Duty
7.5
20AE011
Heavy Duty
7.5
20AE011
Normal Duty
10
20AE017
Heavy Duty
10
20AE017
Normal Duty
15
20AE022
Heavy Duty
15
20AE022
Normal Duty
20
20AE027
Heavy Duty
20
20AE027
Normal Duty
25
20AE032
Heavy Duty
25
20AE032
Normal Duty
30
20AE041
Heavy Duty
30
20AE041
Normal Duty
40
20AE052
Heavy Duty
40
20AE052
Normal Duty
50
Output Line Reactor➊
IP 00 (Open Style)
IP 11 (Nema Type 1)
IP 00 (Open Style)
IP 11 (Nema Type 1)
Catalog Number
Catalog Number
Catalog Number
Catalog Number
1321-3R1-C
1321-3R1-C
1321-3R2-B
1321-3R2-B
1321-3R2-A
1321-3R4-C
1321-3R4-C
1321-3R4-C
1321-3R4-C
1321-3R8-C
1321-3R8-C
1321-3R12-C
1321-3R12-C
1321-3R12-B
1321-3R12-B
1321-3R18-B
1321-3R18-B
1321-3R25-B
1321-3R25-B
1321-3R35-C
1321-3R35-C
1321-3R35-B
1321-3R35-B
1321-3R45-B
1321-3R45-B
1321-3R55-B
1321-3RA1-C
1321-3RA1-C
1321-3RA2-B
1321-3RA2-B
1321-3RA2-A
1321-3RA2-C
1321-3RA4-C
1321-3RA4-C
1321-3RA4-C
1321-3RA8-C
1321-3RA8-C
1321-3RA12-C
1321-3RA12-C
1321-3RA12-B
1321-3RA12-B
1321-3RA18-B
1321-3RA18-B
1321-3RA25-B
1321-3RA25-B
1321-3RA35-C
1321-3RA35-C
1321-3RA35-B
1321-3RA35-B
1321-3RA45-B
1321-3RA45-B
1321-3RA55-B
1321-3R1-B
1321-3R1-B
1321-3R2-B
1321-3R2-B
1321-3R4-D
1321-3R4-D
1321-3R4-C
1321-3R4-C
1321-3R8-C
1321-3R8-C
1321-3R12-C
1321-3R12-C
1321-3R12-B
1321-3R12-B
1321-3R18-C
1321-3R18-C
1321-3R25-B
1321-3R25-B
1321-3R35-C
1321-3R35-C
1321-3R35-B
1321-3R35-B
1321-3R45-B
1321-3R45-B
1321-3R55-B
1321-3R55-B
1321-3RA1-B
1321-3RA1-B
1321-3RA2-B
1321-3RA2-B
1321-3RA4-D
1321-3RA4-D
1321-3RA4-C
1321-3RA4-C
1321-3RA8-C
1321-3RA8-C
1321-3RA12-C
1321-3RA12-C
1321-3RA12-B
1321-3RA12-B
1321-3RA18-C
1321-3RA18-C
1321-3RA25-B
1321-3RA25-B
1321-3RA35-C
1321-3RA35-C
1321-3RA35-B
1321-3RA35-B
1321-3RA45-B
1321-3RA45-B
1321-3RA55-B
1321-3RA55-B
1321-3R1-A
1321-3R1-B
1321-3R2-C
1321-3R2-C
1321-3R2-B
1321-3R4-D ➋
1321-3R4-D ➋
1321-3R4-D
1321-3R4-D
1321-3R8-D
1321-3R8-D
1321-3R12-C ➋
1321-3R12-C ➋
1321-3R12-C
1321-3R12-C
1321-3R18-C
1321-3R18-C
1321-3R25-C
1321-3R25-C ➋
1321-3R35-C ➋
1321-3R35-C ➋
1321-3R35-C ➋
1321-3R35-C ➋
1321-3R45-C
1321-3R45-C
1321-3R55-C
1321-3RA1-A
1321-3RA1-B
1321-3RA2-C
1321-3RA2-C
1321-3RA2-B
1321-3RA4-D ➋
1321-3RA4-D ➋
1321-3RA4-D
1321-3RA4-D
1321-3RA8-D
1321-3RA8-D
1321-3RA12-C ➋
1321-3RA12-C ➋
1321-3RA12-C
1321-3RA12-C
1321-3RA18-C
1321-3RA18-C
1321-3RA25-C
1321-3RA25-C ➋
1321-3RA35-C ➋
1321-3RA35-C ➋
1321-3RA35-C ➋
1321-3RA35-C ➋
1321-3RA45-C
1321-3RA45-C
1321-3RA55-C
1321-3R1-B
1321-3R1-B
1321-3R2-C
1321-3R2-C
1321-3R4-D ➋
1321-3R4-D ➋
1321-3R4-D
1321-3R4-D
1321-3R8-D
1321-3R8-D
1321-3R12-C ➋
1321-3R12-C ➋
1321-3R12-C
1321-3R12-C
1321-3R18-C
1321-3R18-C
1321-3R25-C
1321-3R25-C
1321-3R35-C ➋
1321-3R35-C ➋
1321-3R35-C ➋
1321-3R35-C ➋
1321-3R45-C
1321-3R45-C
1321-3R55-C
1321-3R55-C
1321-3RA1-B
1321-3RA1-B
1321-3RA2-C
1321-3RA2-C
1321-3RA4-D ➋
1321-3RA4-D ➋
1321-3RA4-D
1321-3RA4-D
1321-3RA8-D
1321-3RA8-D
1321-3RA12-C ➋
1321-3RA12-C ➋
1321-3RA12-C
1321-3RA12-C
1321-3RA18-C
1321-3RA18-C
1321-3RA25-C
1321-3RA25-C
1321-3RA35-C ➋
1321-3RA35-C ➋
1321-3RA35-C ➋
1321-3RA35-C ➋
1321-3RA45-C
1321-3RA45-C
1321-3RA55-C
1321-3RA55-C
➊ Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.
➋ Reactors sized at 4% impedance.
17
Packaged Drives Program
Packaged Drives Overview
The PowerFlex 70 Packaged Drives Program allows users to create drive packages based on their specific needs. This
program enhances stand-a-lone drive functionality through additional control, power and packaging options which are
ideal for OEM and end users with special installation needs.
The program has three levels:
Quick Ship
Quick Ship products are intended to meet faster than normal delivery requirements. Pre-defined catalog strings are offered
to support shipping one to three business days from date of order entry. The current offering is based on NEMA 1 (IP20)
and NEMA 4/12 (IP65), 480V, top of frame ratings for frames A-C and frame D @ 20 Hp. These packages are a subset of
the Standard Packaged Drives Program noted below and can be ordered through the Passport order entry system. This
program uses the Standard Control version of the PowerFlex 70.
Standard Packaged Drives
The Standard Packaged Drives Program allows users to create drive packages based on their specific needs. A complete
drive package may be specified by assembling a single catalog number string that includes a base drive and all required
options. Packaging is available for 480V requirements in NEMA Type 1 (IP20), NEMA 4/12 (IP65) indoor, and
NEMA 3/4 (IP65) outdoor. The program consists of a fully defined catalog string identified within the price sheet.
Focused on higher volume, repeat business, the standard designs provide consistent manufacturing and minimizes
customer resources by reducing engineering, manufacturing and installation time. Typical delivery is 10 business days
from order entry and can be ordered through the Passport order entry system. This program uses the Enhanced Control
version of the PowerFlex 70.
Engineered Drives
The Engineered Drives Program offers users the ability to create drive packages beyond the Standard Packaged Drives
offering. Packaging is available for 208V, 240V, 480V and 600V requirements. This program supports both the Standard
and the Enhanced Control versions of the PowerFlex 70. Options may or may not be defined within this publication.
Product can be ordered by:
• Assembling a catalog string from the options listed in this publication.
Engineered options that are listed within this publication will be specified by the heading “Engineered Drives Program
Only” and will have varied lead-times.
• Entering a custom quote request for additional options not listed.
A custom quote will require a Passport quote using “SP-SDB-CUSTOM” as the line item part number and entering a
description of the base catalog string and custom options in the Competitive Summary. For questions or help with a
custom quote please contact the Engineered Drives Group at 262-512-8415.
18
Packaged Drives Program
Quick Ship Program
➊
The Quick Ship Program order entry system has been simplified, minimizing the time required to place an order. To enter your order,
type in the first 14 characters of the string and the system will complete the rest.
Program Features
Standard Features
• Standard Control
• 480V top of frame NEMA Type 1 or
NEMA Type 4/12 packages
• Pre-determined catalog numbers
• Delivery within 1 to 3 business days of order entry
• Four different 480V PowerFlex 70 flange mount drives [21AQD]
• NEMA Type 1 (IP 20) [-AA] or
NEMA Type 4/12 (IP 65) indoor enclosure [-AF]
• Full Numeric LCD HIM, door mounted [-C3]
• Fuse Disconnect [-DS]
• 115V ac Control Power Transformer [-CF]
• Hand/Off/Auto Selector Switch [-D1A]
• Drive Run Pilot Light [-D2A]
• Drive Fault Pilot Light [-D2B]
• Control Power On Pilot Light [-D3A]
• Drive Fault Control Relay [-JF]
• Drive Run Control Relay [-JR]
Quick Ship Catalog Entry
Normal Duty
Frame Hp
IP20, NEMA Type 1
A
2.0
B
5.0
C
10
D
20
IP65, NEMA Type 4/12
A
2.0
B
5.0
C
10
D
20
Heavy Duty
Hp
Type in Catalog
Number
Name Plated Catalog Number
Dimensions
(in inches)
Approx. Weight
(in lbs.)
1.5
3.0
7.5
15
21AQD3P4-AA-DS
21AQD8P0-AA-DS
21AQD014-AA-DS
21AQD027-AA-DS
21AQD3P4-AA-DS-C3-CF-D1A-D2A-D2B-D3A-JF-JR
21AQD8P0-AA-DS-C3-CF-D1A-D2A-D2B-D3A-JF-JR
21AQD014-AA-DS-C3-CF-D1A-D2A-D2B-D3A-JF-JR
21AQD027-AA-DS-C3-CF-D1A-D2A-D2B-D3A-JF-JR
32h x 24w x 16d
32h x 24w x 16d
32h x 24w x 16d
38h x 24w x 16d
225
225
235
250
1.5
3.0
7.5
15
21AQD3P4-AF-DS
21AQD8P0-AF-DS
21AQD014-AF-DS
21AQD027-AF-DS
21AQD3P4-AF-DS-C3-CF-D1A-D2A-D2B-D3A-JF-JR
21AQD8P0-AF-DS-C3-CF-D1A-D2A-D2B-D3A-JF-JR
21AQD014-AF-DS-C3-CF-D1A-D2A-D2B-D3A-JF-JR
21AQD027-AF-DS-C3-CF-D1A-D2A-D2B-D3A-JF-JR
32h x 24w x 16d
32h x 24w x 16d
32h x 24w x 16d
38h x 24w x 16d
225
225
235
250
➊ Consult factory for orders larger than one drive per frame size.
Standard Packaged Drives Program
NEMA Type 1
NEMA Type 4/12 Indoor
NEMA Type 3/4 Outdoor
•
•
•
•
Enhanced Control
Flange Mount Drive
Welded Construction
480V Rating
All Enclosure Types
•
•
•
•
•
•
•
•
•
•
Drive Input Protection Options
Input/Output Contactors
Bypass Options
Input/Output Line Reactor Options
115V Control Power Options
Control Interface and Feedback Options
Human Interface Modules
Motor Interface Options
Operator Devices
Drawing and Test Options
Engineered Drives Program
•
•
•
•
Drive Packages beyond the Standard Packaged Drives Program
Enhanced and Standard Control
Defined and Undefined Options
Pre-determined Options or Custom Quotation
19
Packaged Drives Program
Approximate Dimensions – Standard Packaged Drives Program
W
W
W
D
D
H
D
D
H
H
NEMA Type 1
(Ventilated)
Figure 1
NEMA Type 4
Figure 2
Figure 3
Maximum Enclosure Dimensions
Enclosure Style for Flange Mounted Drives
NEMA Type 1, Option Code A NEMA Type 4/12 Indoor, Option Code D
NEMA Type 3/4, Option Code E
Ratings
All Options
B0, C1, C5, S1,
ND
Hp
HD
Hp
S9…S13, S16,
Power
P1…P3 or P6,
Flex 70 Drive
Mounted
Drive Flange
Options & All
HIMs
Frame Drive
Cat. No. Figure Style Figure
Size
0.5
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
0.33
0.75
1.5
2.0
3.0
5.0
7.5
10
15
20
25
30
40
A
A
A
B
B
C
C
D
D
D
D
E
E
D1P1
D2P1
D3P4
D5P0
D8P0
D011
D014
D022
D027
D034
D040
D052
D065
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Style
3
3
3
3
3
3
3
4
4
4
4
6
6
B0, C1, C5, S1, All Options Less
Line Reactor
S9…S13, S16,
P1…P3 or P6,
Drive Mounted
Options & All
NEMA 4 HIMs
Figure Style
Figure Style
480V ac, Three-Phase Drives
1
1
2
3
1
1
2
3
1
1
2
3
1
1
2
3
1
1
2
3
1
1
2
3
1
1
2
3
1
1
2
4
1
1
2
4
1
1
2
4
1
1
2
4
1
2
2
6
1
2
2
6
All Options
B0, C1, C5, S1,
S9…S13, S16,
P1…P3 or P6,
Drive Mounted
Options
All Options Less
Line Reactor
All Options
Figure
Style
Figure
Style
Figure
Style
Figure
Style
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
4
4
4
4
5
5
5
5
7
7
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
4
4
5
5
6
6
2
2
2
2
2
2
2 or 3 ➊
2 or 3 ➊
3
3
3
3
3
3
3
4
5
5
5
5 or 8 ➊
5 or 8 ➊
8
8
8
9
9
➊ Figure 2, Style 5 when one line reactor selected. Figure 3, Style 8 when two line reactors selected.
Enclosure Dimensions
Figure
1
1
2
2
2
1
1
2
2
2
2
2
3
3
Style
1
2
3
4
6
1
2
3
4
5
6
7
8
9
Enclosure Rating
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 4/12 Indoor, NEMA 4 Outdoor
NEMA 4/12 Indoor, NEMA 4 Outdoor
NEMA 4/12 Indoor, NEMA 4 Outdoor
NEMA 4/12 Indoor, NEMA 4 Outdoor
NEMA 4/12 Indoor, NEMA 4 Outdoor
NEMA 4/12 Indoor, NEMA 4 Outdoor
NEMA 4/12 Indoor, NEMA 4 Outdoor
NEMA 4/12 Indoor, NEMA 4 Outdoor
NEMA 4/12 Indoor, NEMA 4 Outdoor
➊ Depth includes 6.35 mm (2.5 in) for Operator Handle when ordered.
20
Option Code
(Position d)
A
A
A
A
A
D or E
D or E
D or E
D or E
D or E
D or E
D or E
D or E
D or E
Dimensions
H x W x D (mm)
H x W x D (in)
812.8 x 330.2 x 484.1
32 x 13 x 19.06
1,270.0 x 406.4 x 484.1
50 x 16 x 19.06
812.8 x 609.6 x 484.1
32 x 24 x 19.06
965.2 x 609.6 x 484.1
38 x 24 x 19.06
1,270.0 x 762.0 x 484.1
50 x 30 x 19.06
812.8 x 330.2 x 484.1
32 x 13 x 19.06
1,270.0 x 406.4 x 484.1
50 x 16 x 19.06
812.8 x 609.6 x 484.1
32 x 24 x 19.06
965.2 x 609.6 x 484.1
38 x 24 x 19.06
1,270.0 x 609.6 x 484.1
50 x 24 x 19.06
1,270.0 x 762.0 x 484.1
50 x 30 x 19.06
1,270.0 x 914.4 x 484.1
50 x 36 x 19.06
812.8 x 831.9 x 484.1
50 x 32.75 x 19.06
1,270.0 x 984.3 x 484.1
50 x 38.75 x 19.06
Installation Considerations
Power Wiring
The PowerFlex 70 has the following built in protective features to help simplify installation:
• Ground fault protection during start-up and running helps ensure reliability
• Electronic motor moverload protection increases motor life
• Removable MOV to ground and common mode capacitors to ground, ensures compatibility with ungrounded systems
• 6kV transient protection increased robustness for 380-480V system voltages
There are many other factors that must be considered for optimal performance in any given application. The block
diagram below highlights the primary installation considerations. Consult the PowerFlex Reference Manual, Publication
PFLEX-RM001…, available on-line at www.ab.com/manuals/dr, for detailed recommendations on input power
conditioning, CE conformance (EMC filtering), dynamic braking, reflected wave protection, motor cables types and
motor cable distances.
Block Diagram
Branch Circuit Protective Devices – See Tables on page 26
Input Power Conditioning – See PowerFlex Reference Manual
EMC Requirements – See PowerFlex Reference Manual
Removable MOV and
Common Mode Capacitors
(Located underneath cover, see
PowerFlex Reference Manual)
Power Terminal Block – See Description Below
L1
R
L2
S
L3 BR1 BR2 T1
T +DC BRK U
T2
V
T3
W
PE
PE
Dynamic Brake Resistor – See page 14
Reflected Wave Protection – (Consult the PowerFlex Reference Manual)
Motor Cable Type and Length Recommendations – See page 28
Class 10 Overload Protection – Provided by the PowerFlex 70 drive
Motor – See publication MOTORS-CA001…
Power Terminal Block
Terminal
R
S
T
BR1
BR2
U
V
W
PE
PE
-DC
+DC
Description
R (L1)
S (L2)
T (L3)
DC Brake
DC Brake
U (T1)
V (T2)
W (T3)
PE Ground
PE Ground
DC Bus (–)
DC Bus (+)
Notes
AC Line Input Power
AC Line Input Power
AC Line Input Power
Dynamic Brake Resistor Connection
Dynamic Brake Resistor Connection
To Motor
To Motor
To Motor
Power Wiring
Name
Power Terminal Block
SHLD terminal
Frame
A, B, & C
D
E
All
Wire Size Range ➊
Maximum
3.5 mm2 (12 AWG)
8.4 mm2 (8 AWG)
25.0 mm2 (3 AWG)
—
Minimum
0.3 mm2 (22 AWG)
0.8 mm2 (18 AWG)
2.5 mm2 (14 AWG)
—
Torque
Maximum
0.66 N-m (5.5 lb.-in.)
1.7 N-m (15 lb.-in.)
2.71 N-m (24 lb.-in.)
1.6 N-m (14 lb.-in.)
Recommended
0.6 N-m (5 lb.-in.)
1.4 N-m (12 lb.-in.)
2.71 N-m (24 lb.-in.)
1.6 N-m (14 lb.-in.)
➊ Maximum/minimum sizes that the terminal block will accept - these are not recommendations.
21
Installation Considerations
Control Wiring
14
26
1
13
No. Signal
Factory Default
Description
1
Digital In1 Sel
2
3
4
5
6
7
8
9
10
11
12
Digital In2 Sel
Digital In3 Sel
Digital In4 Sel
Digital In5 Sel
Digital In6 Sel
24V Common
Digital In Common
+24V dc
+10V Pot Reference
Digital Out 1 – N.O. ➊
Digital Out 1 Common
Stop – CF
(CF = Clear Fault)
Start
Auto/Man
Speed Sel 1
Speed Sel 2
Speed Sel 3
–
–
–
–
NOT Fault
11.2 mA @ 24V dc
19.2V minimum on state
3.2V maximum off state
Important: Use only 24V dc, not suitable for 115V ac circuitry.
Inputs can be wired as sink or source.
13
Digital Out 1 – N.C. ➊
14
15
16
17
18
19
20
21
22
Analog In 1 (– Volts)
Analog In 1 (+ Volts)
Analog In 1 (– Current)
Analog In 1 (+ Current)
Analog In 2 (– Volts)
Analog In 2 (+ Volts)
Analog In 2 (– Current)
Analog In 2 (+ Current)
10V Pot Common
Analog Out (– Volts)
Analog Out (– Current)
Analog Out (+ Volts)
Analog Out (+ Current)
Digital Out 2 – N.O.
Digital Out 2 Common
Digital Out 2 – N.C.
23
24
25
26
361 - 366
Drive supplied power for Digital In1-6 inputs.
150mA maximum load.
2 k ohm minimum load.
Max Resistive Load
Max Inductive Load
250V ac / 30V dc
250V ac / 30V dc
50 VA / 60 Watts
25 VA / 30 Watts
Minimum DC Load
Fault
10 µA, 10 mV dc
Voltage – Reads value at 14 Non-isolated, 0 to +10V, 10 bit, 100k ohm input impedance. ➌
& 15 ➋
380 - 387
320 - 327
Non-isolated, 4-20mA, 10 bit, 100 ohm input impedance. ➌
Voltage – Reads value at 18 Isolated, bipolar, differential, 0 to +10V unipolar (10 bit) or ±10V bipolar (10 bit & sign),
& 19 ➋
100k ohm input impedance.➍
Isolated, 4-20mA, 10 bit & sign, 100 ohm input impedance. ➍
Output Freq ➋
0 to +10V, 10 bit, 10k ohm (2k ohm minimum) load.
0 to 20mA, 10 bit, 400 ohm maximum load. ➎
Referenced to chassis ground.
Common if internal 10V supply (terminal 10) is used.
341 - 344
Run
See description at No.s 11-13.
380 - 387
➊ Contacts shown in unpowered state. Relays change state when drive is powered.
➋ These inputs/outputs are dependent on a number of parameters. See “Related Parameters.”
➌ Differential Isolation - External source must be less than 10V with respect to PE.
➍ Differential Isolation - External source must be maintained at less than 160V with respect to PE. Input provides high common mode immunity.
➎ Analog output current is only available with Enhanced Control drives.
22
Related
Param.
Installation Considerations
Control Wiring, Continued
I/O Wiring
Name
I/O Terminal Block
Wire Size Range ➊
Maximum
1.5 mm2 (16 AWG)
Minimum
0.05 mm2 (30 AWG)
Torque
Maximum
0.55 N-m (4.9 lb.-in.)
Recommended
0.5 N-m (4.4 lb.-in.)
➊ Maximum/minimum sizes that the terminal block will accept - these are not recommendations.
I/O Wiring Examples
Input/Output
Connection Example
Potentiometer Unipolar Speed Reference
10k Ohm Pot. Recommended
(2k Ohm minimum)
Required Parameter Settings
14
15
22
10
Joystick Bipolar Speed Reference
±10V Input
18
19
22
-10V Com +10V
Power Source
Analog Input Bipolar Speed Reference
±10V Input
Analog Input Unipolar Speed Reference
0 to +10V Input
Analog Input, PTC
PTC OT set > 5V
PTC OT cleared < 4V
PTC Short < 0.2V
–
+
18
19
Common
+
18
19
Ferrite
Bead
14
15
1.8k
PTC
22
Select Speed Reference source:
Param. 090 = 1 “Analog In 1”
Adjust Scaling:
Param. 091, 092, 322, 323
Check Results:
Param. 016
Set Direction Mode:
Param. 190 = 1 “Bipolar”
Adjust Scaling:
Param. 091, 092, 325, 326
Check Results:
Param. 017
Adjust Scaling:
Param. 091, 092, 325, 326
Check Results:
Param. 017
Adjust Scaling:
Param. 091, 092, 325, 326
Check Results:
Param. 017
Set Fault Config 1:
Param. 238, Bit #7 = 1 “Enabled”
Set Alarm Config 1:
Param. 259, Bit #11 = 1 “Enabled”
10
3.32k
Ohm
Analog Input Unipolar Speed Reference
4-20 mA Input
Common
+
20
21
Analog Output Unipolar
0 to +10V Output. Can Drive a 2k Ohm load (25
mA short circuit limit)
Configure Input for Current:
Param. 320, Bit #1 = 1 “Current”
Adjust Scaling:
Param. 091, 092, 325, 326
Check Results:
Param. 017
Select Source Value:
Param. 342
Adjust Scaling:
Param. 343, 344
+
–
22
23
23
Installation Considerations
Control Wiring, Continued
Input/Output
Connection Example
Required Parameter Settings
2 Wire Control Non-Reversing
Internal Supply
Disable Digital Input 1:
Param. 361 = 0 “Not Used”
Set Digital Input 2:
Param. 362 = 7 “Run”
2
Stop-Run
7
8
9
2 Wire Control Reversing
External Supply
Run Rev
Set Digital Input 1:
Param. 361 = 8 “Run Forward”
Set Digital Input 2:
Param. 362 = 9 “Run Reverse”
1
2
Run Fwd
8
+24V
3 Wire Control
3 Wire Control
Common
Internal Supply
Use factory default parameter settings.
Stop
1
2
Start
7
8
9
External Supply
Use factory default parameter settings.
Stop
1
2
Start
8
+24V
Common
Digital Output
Form C Relays Energized in Normal State.
11
12
13
24
25
26
or
Power
Source
Enable Input
Shown in enabled state.
Standard Control
Configure with parameter 366
6
24
Select Source:
Param. 380, 384
Enhanced Control
Configure with parameter 366
For dedicated hardware Enable: Remove Enable
Jumper
Specifications
Safe Off Board
Terminal Description
No. Signal
Description
1
2
Monitor - N.C.
Common - N.C.
Normally closed contacts for monitoring relay status.
Maximum Resistive Load: 250V ac / 30V dc / 50 VA / 60 Watts
Maximum Inductive Load: 250V ac / 30V dc / 25 VA / 30 Watts
3
4
+24V dc
24V Common
Connections for user supplied power to energize coil.
4 3 2 1
Connection Examples
For detailed connection examples refer to the DriveGuard™ Safe-Off Option for PowerFlex 70 AC Drives
User Manual, publication PFLEX-UM001….
Encoder Board
Terminal Description
No. Signal
1
2
3
4
5
6
Description
5V/12V Power
Power Return
Encoder B (NOT)
Encoder B
Encoder A (NOT)
Encoder A
Internal power source 250 mA (isolated).
Single channel or quadrature B input.
Single channel or quadrature A input.
1
6
Jumper Settings
Receive Voltage
= 12V
= 5V
= 12V
= 5V
Send Voltage
Connection Examples
I/O
Connection Example
Encoder
Power –
External
to
SHLD
Power Source
Encoder Signal –
Single-Ended,
Dual Channel
Encoder
Signal –
Differential,
Dual Channel
+
Common
I/O
Connection Example
Encoder Power –
+12V DC
(250 mA)
1
Internal Drive
2
Power
Common
3
4
Internal (drive)
to SHLD
5
12V dc, 250mA
External
Power
Supply
6
to Power Supply
Common
1
2
3
4
5
6
B NOT
B
A NOT
A
1
2
3
4
5
6
to SHLD
B NOT
B
A NOT
A
to SHLD
25
Specifications
Branch Circuit Protection Devices and Power Dissipation
Frame➒
Hp
Rating
Drive
Catalog
Number
ND HD
208 Volt AC Input
20AB2P2 A 0.5 0.33
20AB4P2 A 1
0.75
20AB6P8 B 2
1.5
20AB9P6 B 3
2
20AB015 C 5
3
20AB022
Power
Dissipation ➑
2.9
5.6
10
14
16
19.2
20.5
22.6
25.4
33.2
1.1
2
3.6
5.1
5.8
2.5
4.8
7.8
11
17.5
2.7
5.5
10.3
12.1
19.2
3.7
7.4
13.8
16.5
26.6
6
10
15
20
20
6
10
15
25
35
6
10
15
20
20
10
17.5
30
40
70
15
15
30
40
70
7
7
15
30
30
140M-C2E-B40
140M-C2E-B63
140M-C2E-C10
140M-C2E-C16
140M-C2E-C20
140M-D8E-B40
140M-D8E-B63
140M-D8E-C10
140M-D8E-C16
140M-D8E-C20
–
–
140M-F8E-C10
140M-F8E-C16
140M-F8E-C20
–
–
–
–
–
Internal Total
31.4
51.2
67.2
92.7
174.5
5
23.3
8.3
25.3
27.8
37.9
30
50
30
100
100
30
140M-C2E-C25
140M-D8E-C25
140M-F8E-C25
140-CMN-2500
34.2
239.9
20AB028 D 10
20AB042 D 15
20AB054 E 20
20AB070 E 25
240 Volt AC Input
20AB2P2 A 0.5
7.5
10
15
20
29.8
39.8
57.5
72.3
10.7
14.3
20.7
26.0
32.2
43
62.1
78.2
37.9
55.5
72.4
93.1
50.6
74
96.6
124
40
60
80
90
70
100
125
175
40
60
80
90
125
175
200
300
125
175
200
300
50
70
100
100
–
–
–
–
–
–
–
–
140M-F8E-C32
140M-F8E-C45
–
–
140-CMN-4000
140-CMN-6300
140-CMN-6300
140-CMN-9000
48.1
40.3
44.9
51.6
318.5
425.9
539.5
702.3
0.33 2.5
1.1
2.2
2.4
3.3
3
4.5
3
8
15
3
140M-C2E-B25
140M-D8E-B25
–
–
19.2
31.4
20AB4P2 A 1
20AB6P8 B 2
20AB9P6 B 3
20AB015 C 5
20AB022 D 7.5
20AB028 D 10
20AB042 D 15
20AB054 E 20
20AB070 E 25
400 Volt AC Input
20AC1P3 A 0.37
20AC2P1 A 0.75
20AC3P5 A 1.5
20AC5P0 B 2.2
20AC8P7 B 4
20AC011 C 5.5
20AC015 C 7.5
20AC022 D 11
20AC030 D 15
20AC037 D 18.5
20AC043 D 22
20AC060 E 30
20AC072 E 37
480 Volt AC Input
20AD1P1 A 0.5
20AD2P1 A 1
20AD3P4 A 2
20AD5P0 B 3
20AD8P0 B 5
20AD011 C 7.5
20AD014 C 10
20AD022 D 15
20AD027 D 20
20AD034 D 25
20AD040 D 30
20AD052 E 40
20AD065 E 50
0.75
1.5
2
3
5
7.5
10
15
20
4.8
8.7
12.2
13.9
19.9
25.7
38.7
49.8
64.5
2
3.6
5.1
5.8
8.3
10.7
16.1
20.7
26.8
4.2
6.8
9.6
15.3
22
28
42
54
70
4.8
9
10.6
17.4
24.4
33
46.2
63
81
6.4
12
14.4
23.2
33
44
63
84
108
6
15
20
20
25
35
50
60
90
9
15
20
30
45
60
90
100
150
6
15
20
20
25
35
50
60
90
15
25
35
60
80
110
150
200
275
15
25
35
60
80
110
150
200
275
7
15
15
30
30
50
50
100
100
140M-C2E-B63
140M-C2E-C10
140M-C2E-C16
140M-C2E-C16
140M-C2E-C25
–
–
–
–
140M-D8E-B63
140M-D8E-C10
140M-D8E-C16
140M-D8E-C16
140M-D8E-C25
–
–
–
–
–
140M-F8E-C10
140M-F8E-C16
140M-F8E-C16
140M-F8E-C25
140M-F8E-C32
140M-F8E-C45
–
–
–
–
–
–
140-CMN-2500
140-CMN-4000
140-CMN-6300
140-CMN-6300
140-CMN-9000
20.5
22.6
25.4
33.2
34.2
48.1
40.3
44.9
51.6
51.2
67.2
92.7
174.5
239.9
318.5
425.9
539.5
702.3
0.25
0.55
1.1
1.5
3
4
5.5
7.5
11
15
18.5
22
30
1.6
2.5
4.3
6.5
11.3
11
15.1
21.9
30.3
35
40.7
56.8
68.9
1.1
1.8
3
4.5
7.8
7.6
10.4
15.2
21
24.3
28.2
39.3
47.8
1.3
2.1
3.5
5
8.7
11.5
15.4
22
30
37
43
60
72
1.4
2.4
4.5
5.5
9.9
13
17.2
24.2
33
45
56
66
90
1.9
3.2
6
7.5
13.2
17.4
23.1
33
45
60
74
90
120
3
4
6
10
15
15
20
30
40
50
60
80
90
3
6
6
10
17.5
25
30
45
60
80
90
125
150
3
4
6
10
15
15
20
30
40
50
60
80
90
5
8
12
20
30
45
60
80
120
125
150
225
250
15
15
15
20
30
40
60
80
120
140
160
240
280
3
7
7
15
15
15
20
30
50
50
70
80
100
140M-C2E-B16
140M-C2E-B25
140M-C2E-B63
140M-C2E-C10
140M-C2E-C16
140M-C2E-C16
140M-C2E-C16
140M-C2E-C25
–
–
–
–
–
–
140M-D8E-B25
140M-D8E-B63
140M-D8E-C10
140M-D8E-C16
140M-D8E-C16
140M-D8E-C16
140M-D8E-C25
–
–
–
–
–
–
–
–
140M-F8E-C10
140M-F8E-C16
140M-F8E-C16
140M-F8E-C16
140M-F8E-C25
140M-F8E-C32
140M-F8E-C45
–
–
–
–
–
–
–
–
–
–
140-CMN-2500
140-CMN-4000
140-CMN-4000
140-CMN-6300
140-CMN-6300
140-CMN-9000
17.9
19.5
21.6
24.0
28.2
27.8
32.0
34.2
42.9
40.5
41.5
50.0
57.7
29.4
47.3
65.2
88.6
127.7
167.8
225.3
339.6
475.8
404.3
438.3
550.8
689.7
0.33
0.75
1.5
2
3
5
7.5
10
15
20
25
30
40
1.3
2.4
3.8
5.6
9.8
9.5
12.5
19.9
24.8
31.2
36.7
47.7
59.6
1.1
2
3.2
4.7
8.4
7.9
10.4
16.6
20.6
25.9
39.7
39.7
49.6
1.1
2.1
3.4
5
8
11
14
22
27
34
40
52
65
1.2
2.4
4.5
5.5
8.8
12.1
16.5
24.2
33
40.5
51
60
78
1.6
3.2
6
7.5
12
16.5
22
33
44
54
68
80
104
3
3
6
10
15
15
20
25
35
40
50
60
80
3
6
6
10
15
20
30
45
60
70
90
110
125
3
3
6
10
15
15
20
25
35
40
50
60
80
4
8
12
20
30
40
50
80
100
125
150
200
250
15
15
15
20
30
40
50
80
100
125
150
200
250
3
3
7
15
15
15
20
30
50
50
50
70
100
140M-C2E-B16
140M-C2E-B25
140M-C2E-B40
140M-C2E-B63
140M-C2E-C10
140M-C2E-C16
140M-C2E-C16
140M-C2E-C25
–
–
–
–
–
–
140M-D8E-B25
140M-D8E-B40
140M-D8E-B63
140M-D8E-C10
140M-D8E-C16
140M-D8E-C16
140M-D8E-C25
–
–
–
–
–
–
–
–
140M-F8E-C10
140M-F8E-C16
140M-F8E-C16
140M-F8E-C25
140M-F8E-C32
140M-F8E-C45
140M-F8E-C45
–
–
–
–
–
–
–
–
–
–
140-CMN-2500
140-CMN-4000
140-CMN-4000
140-CMN-6300
140-CMN-9000
17.9
19.5
21.6
24.0
28.2
27.8
32.0
34.2
42.9
40.5
41.5
50.0
57.7
29.4
47.3
65.2
88.6
127.7
167.8
225.3
339.6
475.8
404.3
438.3
550.8
689.7
➊
➋
➌
➍
➎
➏
D 7.5
Input Branch Circuit Protection Devices
Dual
➍
Element
➌
Motor
Input
Time Delay Non-Time
Circuit Circuit
Ratings
Output Amps
Fuse
Delay Fuse Breaker Protector 140M Motor Starter with Adjustable Current Range ➎ ➏
➊
➋
➊
➋
Amps kVA Cont. 1 Min. 3 Sec. Min. Max. Min. Max. Amps
Amps
Available Catalog Numbers ➐
Minimum protection device size is the lowest rated device that supplies maximum protection without nuisance tripping.
Maximum protection device size is the highest rated device that supplies drive protection.
Circuit breaker - inverse time breaker.
Motor Circuit Protector - instantaneous trip circuit breaker.
Bulletin 140M with adjustable current range should have the current trip set to the minimum range that the device will not trip.
Manual Self-Protector (Type E) Combination Motor Controller, UL Listed for 208 Wye, 240 Wye or Delta, 480Y/277 or 600y/347. Not UL listed for use on 480V or 600V
Delta/Delta Systems.
➐ The AIC ratings of the Bulletin 140M Motor Protector may vary without testing. See Publication 140M-SG001B-EN-P.
➑ At 4kHz PWM frequency. See PowerFlex Reference Manual for derating above 4kHz.
➒ For internally filtered drives, Frame A increases to Frame B. For enclosure Code C (IP66, NEMA 4X/12), Frame A increases to Frame B and Frame C increases to Frame D.
26
Specifications
Branch Circuit Protection Devices and Power Dissipation, Continued)
Frame➒
Hp
Rating
Drive
Catalog
Number
ND HD
600 Volt AC Input
20AE0P9 A 0.5 0.33
20AE1P7 A 1
0.75
20AE2P7 A 2
1.5
20AE3P9 B 3
2
20AE6P1 B 5
3
20AE9P0 C 7.5 5
20AE011 C 10 7.5
20AE017 D 15 10
20AE022 D 20 15
20AE027 D 25 20
20AE032 D 30 25
20AE041 E 40 30
20AE052 E 50 40
Input Branch Circuit Protection Devices
Dual
➍
Element
➌
Motor
Input
Time Delay Non-Time
Circuit Circuit
Ratings
Output Amps
Fuse
Delay Fuse Breaker Protector 140M Motor Starter with Adjustable Current Range ➎ ➏
➊
➋
➊
➋
Amps kVA Cont. 1 Min. 3 Sec. Min. Max. Min. Max. Amps
Amps
Available Catalog Numbers ➐
1.3
1.9
3
4.4
7.5
7.7
9.8
15.3
20
24.8
29.4
37.6
47.7
1.3
2
3.1
4.5
7.8
8
10.1
15.9
20.8
25.7
30.5
39.1
49.6
0.9
1.7
2.7
3.9
6.1
9
11
17
22
27
32
41
52
1.1
2
3.6
4.3
6.7
9.9
13.5
18.7
25.5
33
40.5
48
61.5
1.4
2.6
4.8
5.9
9.2
13.5
18
25.5
34
44
54
64
82
3
3
4
6
10
10
15
20
25
35
40
50
60
3
6
6
8
12
20
20
35
45
60
70
90
110
3
3
4
6
10
10
15
20
25
35
40
50
60
3.5
6
10
15
20
35
40
60
80
100
125
150
200
15
15
15
15
20
35
40
60
80
100
125
150
200
3
3
7
7
15
15
15
30
30
50
50
100
100
140M-C2E-B16
140M-C2E-B25
140M-C2E-B40
140M-C2E-B63
140M-C2E-C10
140M-C2E-C10
140M-C2E-C16
140M-C2E-C20
140M-C2E-C25
–
–
–
–
–
140M-D8E-B25
140M-D8E-B40
140M-D8E-B63
140M-D8E-C10
140M-D8E-C10
140M-D8E-C16
140M-D8E-C20
140M-D8E-C25
–
–
–
–
–
–
–
–
140M-F8E-C10
140M-F8E-C10
140M-F8E-C16
140M-F8E-C20
140M-F8E-C25
140M-F8E-C25
140M-F8E-C32
140M-F8E-C45
–
–
–
–
–
–
–
–
–
140-CMN-2500
140-CMN-2500
140-CMN-4000
140-CMN-4000
140-CMN-6300
Power
Dissipation ➑
Internal Total
17.9
19.5
21.6
24.0
28.2
27.8
32.0
34.2
42.9
42.4
43.4
51.8
59.9
29.4
47.3
65.2
88.6
127.7
167.8
225.3
339.6
475.8
323.8
355.3
441.7
561.3
➊
➋
➌
➍
➎
➏
Minimum protection device size is the lowest rated device that supplies maximum protection without nuisance tripping.
Maximum protection device size is the highest rated device that supplies drive protection.
Circuit breaker - inverse time breaker.
Motor Circuit Protector - instantaneous trip circuit breaker.
Bulletin 140M with adjustable current range should have the current trip set to the minimum range that the device will not trip.
Manual Self-Protector (Type E) Combination Motor Controller, UL Listed for 208 Wye, 240 Wye or Delta, 480Y/277 or 600y/347. Not UL listed for use on 480V or 600V
Delta/Delta Systems.
➐ The AIC ratings of the Bulletin 140M Motor Protector may vary without testing. See Publication 140M-SG001B-EN-P.
➑ At 4kHz PWM frequency. See PowerFlex Reference Manual for derating above 4kHz.
➒ For internally filtered drives, Frame A increases to Frame B. For enclosure Code C (IP66, NEMA 4X/12), Frame A increases to Frame B and Frame C increases to Frame D.
27
Specifications
Maximum Lead Lengths (in feet)
Carrier
480V Hp Freq.
Rating (kHz)
1488 Volt Motor
1600 Volt Motor
1000 Volt Motor
1200 Volt Motor
NEMA MG1-1998
1329 R/L
Shld. ➊ Shld. ➋ Un-Shld. Shld. ➊ Shld. ➋ Un-Shld. Shld. ➊ Shld. ➋ Un-Shld. Shld. ➊ Shld. ➋ Un-Shld.
0.5
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
1
2
3
5
7.5
10
15
20-50
2
4
6
8
10
2
4
6
8
10
2
4
6
8
10
2
4
6
8
10
2
4
6
8
10
2
4
6
8
10
2
4
6
8
10
2
4
6
8
10
2
4
6
8
10
60
60
60
60
60
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
80
80
80
80
80
50
50
50
50
50
50
50
50
50
50
80
80
80
80
80
70
70
70
70
70
40
40
40
40
40
30
30
30
30
30
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
50
50
50
50
50
50
50
50
50
50
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
175
175
175
175
175
275
250
250
250
200
275
250
250
240
220
220
220
220
220
220
280
280
280
280
280
300
300
300
300
300
300
300
300
300
300
600
400
400
400
400
600
400
200
160
160
60
60
50
50
50
55
55
55
55
55
75
75
75
75
75
75
75
75
75
75
80
80
80
80
80
60
60
60
60
60
60
60
60
60
60
80
80
80
80
80
80
80
80
80
80
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
175
175
175
175
175
275
250
250
250
250
275
250
250
250
250
425
400
425
400
400
450
400
400
300
300
400
400
400
400
300
400
400
400
400
300
600
600
600
600
600
600
600
600
600
600
150
130
130
130
130
180
180
170
160
160
500
400
360
260
260
600
520
520
380
380
600
600
560
400
360
600
600
520
400
320
600
600
560
440
380
600
600
600
500
400
600
600
600
600
340
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
175
175
175
175
175
275
250
250
250
250
275
250
250
250
250
425
400
425
400
400
450
400
400
300
300
400
400
400
400
300
400
400
400
400
300
600
600
600
600
600
600
600
600
600
600
150
150
150
150
150
350
300
280
260
240
500
400
400
400
400
600
600
600
580
550
600
600
600
600
580
600
600
600
560
500
600
600
600
560
520
600
600
600
600
480
600
600
600
600
600
➊ Cable is Belden 295xx series or equivalent.
➋ Cable is Alcatel C1202 or equivalent. Shielded cable with twisted conductors and no filler.
Notes
– 1000V motor is defined as one assembled without phase paper. 1200V motor is defined as one assembled with phase paper. 1488V motor meets NEMA MG 1-1998
section 31 standard where the insulation can withstand voltage spikes of 3.1 x rated motor voltage due to inverter operation (inverter duty motor). 1600V motor is a
1329R or 1329L. Operation at nominal line voltage. To increase the distance between the drive and the motor, some mitigation device needs to be added to the system
(i.e. an RWR or Terminator).
– Shading indicates limited due to cable charging current.
– NA = Data Not Available at time of publication.
28
Specifications
Control and Performance
Environment
Agency
Certification
Specification
PowerFlex 70 Drive
AC Input Overvoltage Trip:
AC Input Undervoltage Trip:
Bus Overvoltage Trip:
Bus Undervoltage Trip:
Nominal Bus Voltage:
All Drives
Heat Sink Thermistor:
Drive Overcurrent Trip
Software Current Limit:
Hardware Current Limit:
Instantaneous Current Limit:
Line transients:
Control Logic Noise Immunity:
Power Ride-Thru:
Logic Control Ride-Thru:
Ground Fault Trip:
Short Circuit Trip:
Altitude:
Maximum Surrounding Air Temperature without derating:
IP20, NEMA Type 1
IP66, NEMA Type 4X/12
Flange Type
Storage Temperature (all const.):
Atmosphere
Relative Humidity:
Shock:
Vibration:
Type 1, IP30 Flange Type
✔
✔
200-208V Drive
247VAC
120VAC
350VDC
176VDC
281VDC
240V Drive
285VAC
138VAC
405VDC
204VDC
324VDC
380/400 Drive
475VAC
233VAC
675VDC
339VDC
540VDC
480V Drive
570VAC
280VAC
810VDC
407VDC
648VDC
600V Drive
690VAC
345VAC
1013VDC
998VDC
810VDC
Monitored by microprocessor overtemp trip
20-160% of rated current
200% of rated current (typical)
220-300% of rated current (dependent on drive rating)
up to 6000 volts peak per IEEE C62.41-1991
Showering arc transients up to 1500V peak
15 milliseconds at full load
0.5 seconds minimum, 2 seconds typical
Phase-to-ground on drive output
Phase-to-phase on drive output
1000 m (3300 ft) max. without derating
0 to 50 degrees C (32 to 122 degrees F)
0 to 40 degrees C (32 to 104 degrees F)
0 to 50 degrees C (32 to 122 degrees F)
–40 to 70 degrees C (–40 to 158 degrees F)
Important: Drive must not be installed in an area where the ambient atmosphere contains volatile
or corrosive gas, vapors or dust. If the drive is not going to be installed for a period of time, it must be
stored in an area where it will not be exposed to a corrosive atmosphere.
5 to 95% non-condensing
15G peak for 11ms duration (±1.0 ms)
0.152 mm (0.006 in.) displacement, 1G peak
Type 4X/12,
IP66
✔
Listed to UL508C and CAN/CSA-C2.2 No. 14-M91
C
UL
®
US
✔
✔
✔
✔
✔
✔
✔
Marked for all applicable European Directives ➊
EMC Directive (89/336/EEC)
EN 61800-3 Adjustable Speed electrical power drive systems
Low Voltage Directive (73/23/EEC)
EN 50178 Electronic Equipment for use in Power Installations
Certified to AS/NZS, 1997 Group 1, Class A
✔
✔
✔
Certified to Criteria C-2, 1983.
✔
✔
✔
Listed to UL508C for plenums (Rear heatsink only)
..
TUV
Rheinland
Product Safety
W
Category
Protection
E
C
Certified to EN 954-1, Category 3 for 240V, 400V, and 480V ratings of PowerFlex 70 Enhanced Control
with DriveGuard Safe-Off option.
Production inspected
EN 50178
Bauart geprüft
Functional
..
TUV
Rheinland
✔
✔
Safety
Type approved
✔
TUV Approved to EN 954-1, Category 3 for 600V ratings of PowerFlex 70 Enhanced Control with
DriveGuard Safe-Off option.
The drive is also designed to meet the appropriate portions of the following specifications:
NFPA 70 - US National Electrical Code
NEMA ICS 3.1 - Safety standards for Construction and Guide for Selection, Installation and Operation of Adjustable Speed Drive Systems.
IEC 146 - International Electrical Code.
➊ Applied noise impulses may be counted in addition to the standard pulse train causing erroneously high (pulse frequency) readings.
29
Specifications
Control and Performance, Continued
Category
Specification
Electrical
Voltage Tolerance:
Control
Frequency Tolerance:
Input Phases:
Displacement Power Factor
All Drives:
Efficiency:
Maximum Short Circuit Rating:
Actual Short Circuit Rating:
Method:
Carrier Frequency:
Output Voltage Range:
Output Frequency Range:
Frequency Accuracy
Digital Input:
Analog Input:
Frequency Control
Speed Control
Torque Regulation
–10% of minimum, +10% of maximum. See the PowerFlex User Manual,
publication 20A-UM001…, for Full Power and Operating Range.
47-63 Hz.
Three-phase input provides full rating for all drives. Single-phase operation provides 50% of rated current.
0.98 across entire speed range.
97.5% at rated amps, nominal line volts.
200,000 Amps symmetrical.
Determined by AIC rating of installed fuse/circuit breaker.
Sine coded PWM with programmable carrier frequency. Ratings apply to all drives.
2, 3, 4, 5, 6, 7, 8, 9 & 10 kHz
2, 4, 8 & 12 kHz E C .
Drive rating based on 4 kHz
0 to rated motor voltage
0 to 400 Hz
Standard .
Standard .
0 to 500 Hz
EC
Within ±0.01% of set output frequency.
Within ±0.4% of maximum output frequency.
Speed regulation - with Slip Compensation
0.5% of base speed across 40:1 speed range
40:1 operating range
10 rad/sec bandwidth
Speed regulation - with Slip Compensation
0.5% of base speed across 80:1 speed range
80:1 operating range
20 rad/sec bandwidth
Speed regulation - with feedback
0.1% of base speed across 80:1 speed range
80:1 operating range
20 rad/sec bandwidth
Speed regulation - without feedback
0.1% of base speed across 120:1 speed range
120:1 operating range
30 rad/sec bandwidth
Speed regulation - with feedback
0.001% of base speed across 120:1 speed range
1000:1 operating range
125 rad/sec bandwidth
Torque regulation - without feedback +/-10%
Torque regulation - with feedback +/-5%
Selectable Motor Control:
Stop Modes:
Accel/Decel:
Intermittent Overload:
Current Limit Capability:
Electronic Motor Overload Protection:
Encoder
30
Type:
Supply:
Quadrature:
Duty Cycle:
Requirements
.
(Volts per Hertz Mode)
Standard
EC
(Sensorless Vector Mode)
Standard
EC
(Sensorless Vector Mode)
EC
(Vector Control Mode)
EC
(Vector Control Mode)
EC
EC
EC
Sensorless Vector with full tuning. Standard V/Hz with full custom capability and vector control.
Multiple programmable stop modes including - Ramp, Coast, DC-Brake, Ramp-to-Hold and S-curve.
Two independently programmable accel and decel times. Each time may be programmed from 0-3600
seconds in 0.1 sec. increments
110% Overload capability for up to 1 minute
150% Overload capability for up to 3 seconds
Proactive Current Limit programmable from 20 to 160% of rated output current. Independently
programmable proportional and integral gain.
Class 10 protection with speed sensitive response. Investigated by U.L. to comply with N.E.C. Article
430. U.L. File E59272, volume 12.
Incremental, dual channel
5V/12V Configurable +/-5%
90° +/-27° at 25° C.
50% +10%
Encoders must be line driver type, quadrature (dual channel) or pulse (single channel), single-ended or
differential and capable of supplying a minimum of 10 mA per channel. The Encoder Interface Board
accepts 5V or 12V dc square-wave with a minimum high state voltage of 3.5V dc (5V mode) and 7.0V
dc (12V mode). Maximum low state voltage is 1V dc (for both 5V and 12V modes). Maximum input
frequency is 250 kHz.
Specifications
Parameter List
Shaded rows denote Enhanced Control parameters.
Parameter Name
Accel Mask
Accel Owner
Accel Time X
Alarm Config 1
Alarm X @ Fault
Analog In X Hi
Analog In X Lo
Analog In X Loss
Analog In1 Value
Analog In2 Value
Analog Out1 Hi
Analog Out1 Lo
Analog Out1 Sel
Anlg In Config
Anlg In Sqr Root
Anlg Out Absolut
Anlg Out Config
Anlg Out1 Scale
Anlg Out1 Setpt
Auto Rstrt Delay
Auto Rstrt Tries
AutoMan Cnfg
Autotune
Autotune Torque
Break Frequency
Break Voltage
Bus Reg Gain
Bus Reg Kd
Bus Reg Ki
Bus Reg Kp
Bus Reg Mode X
Commanded Freq
Commanded Torque
Compensation
Control Status
Control SW Ver
Current Lmt Gain
Current Lmt Sel
Current Lmt Val
Current Rate Limit
Data In XX
Data Out XX
DB Resistor Type
DB While Stopped
DC Brake Level
DC Brake Lvl Sel
DC Brake Time
DC Bus Memory
DC Bus Voltage
Decel Mask
Decel Owner
Decel Time X
Dig In Status
Dig Out Setpt
Dig Out Status
Dig OutX Level
Dig OutX OffTime
Dig OutX OnTime
DigIn DataLogic
Digital InX Sel
Digital OutX Sel
Direction Mask
Direction Mode
Number
281
293
140, 141
259
229, 230
322, 325
323, 326
324, 327
16
17
343
344
342
320
321
341
340
354
377
175
174
192
61
66
72
71
160
165
160
164
161, 162
2
24
56
440
29
149
147
148
154
300-307
310-317
163
145
158
157
159
13
12
282
294
142, 143
216
379
217
381, 385
383, 387
382, 386
411
361-366
380, 384
279
190
Group
Masks & Owners
Masks & Owners
Ramp Rates
Alarms
Diagnostics
Analog Inputs
Analog Inputs
Analog Inputs
Metering
Metering
Analog Outputs
Analog Outputs
Analog Outputs
Analog Inputs
Analog Inputs
Analog Outputs
Analog Outputs
Analog Outputs
Analog Outputs
Restart Modes
Restart Modes
HIM Ref Config
Torq Attributes
Torq Attributes
Volts per Hertz
Volts per Hertz
Stop/Brake Modes
Stop/Brake Modes
Stop/Brake Modes
Stop/Brake Modes
Stop/Brake Modes
Metering
Metering
Torq Attributes
Torq Attributes
Drive Data
Load Limits
Load Limits
Load Limits
Load limits
Datalinks
Datalinks
Stop/Brake Modes
Stop/Brake Modes
Stop/Brake Modes
Stop/Brake Modes
Stop/Brake Modes
Metering
Metering
Masks & Owners
Masks & Owners
Ramp Rates
Diagnostics
Digital Outputs
Diagnostics
Digital Outputs
Digital Outputs
Digital Outputs
Digital Inputs
Digital Inputs
Digital Outputs
Masks & Owners
Direction Config
Parameter Name
Direction Owner
DPI Data Rate
DPI Port Select
DPI Port Value
DPI Ref Select
Drive Alarm X
Drive Checksum
Drive Logic Rslt
Drive OL Count
Drive OL Mode
Drive Ramp Rslt
Drive Ref Rslt
Drive Status X
Drive Temp
Droop RPM @ FLA
Dyn UserSet Actv
Dyn UsrSet Cnfg
Dyn UserSet Sel
Elapsed kWh
Elapsed MWh
Elapsed Run Time
Enc Position Fdbk
Encoder PPR
Encoder Speed
Fault Amps
Fault Bus Volts
Fault Clear
Fault Clear Mode
Fault Clr Mask
Fault Clr Owner
Fault Config 1
Fault Frequency
Fault X Code
Fault X Time
Fdbk Filter Sel
Feedback Select
Flux Braking
Flux Current
Flux Current Ref
Flux Up Mode
Flux Up Time
Flying Start En
Flying StartGain
Gnd Warn Level
HighRes Ref
Inertia Autotune
IR Voltage Drop
Ixo Voltage Drop
Jog Mask
Jog Owner
Jog Speed
Jog Speed 1
Jog Speed 2
Kf Speed Loop
Ki Speed Loop
Kp Speed Loop
Language
Last Stop Source
Load Frm Usr Set
Load Loss Level
Load Loss Time
Local Mask Act
Local Mask
Local Owner
Logic Mask
Number
291
270
274
275
298
211, 212
203
271
219
150
273
272
209, 210
218
152
206
204
205
14
9
10
414
413
415
225
226
240
241
283
295
238
224
243-249
244-250
416
80
166
5
63
57
58
169
170
177
308
67
62
64
278
290
100
100
108
447
445
446
201
215
198
187
188
598
285
297
276
Group
Masks & Owners
Comm Control
Comm Control
Comm Control
Comm Control
Diagnostics
Drive Memory
Comm Control
Diagnostics
Load Limits
Comm Control
Comm Control
Diagnostics
Diagnostics
Stop/Brake Modes
Drive Memory
Drive Memory
Drive Memory
Metering
Metering
Metering
Speed Feedback
Speed Feedback
Speed Feedback
Diagnostics
Diagnostics
Faults
Faults
Masks & Owners
Masks & Owners
Faults
Diagnostics
Faults
Faults
Speed Feedback
Spd Mode & Limits
Stop/Brake Modes
Metering
Torq Attributes
Torq Attributes
Torq Attributes
Restart Modes
Restart Modes
Restart Modes
Datalinks
Torq Attributes
Torq Attributes
Torq Attributes
Masks & Owners
Masks & Owners
Discrete Speeds
Discrete Speeds
Discrete Speeds
Speed Regulator
Speed Regulator
Speed Regulator
Drive Memory
Diagnostics
Drive Memory
Power Loss
Power Loss
Security
Masks & Owners
Masks & Owners
Masks & Owners
31
Specifications
Parameter List, Continued
Parameter Name
Man Ref Preload
Maximum Freq
Maximum Speed
Maximum Voltage
Minimum Speed
MOP Frequency
MOP Mask
MOP Owner
MOP Rate
Motor Cntl Sel
Motor Fdbk Type
Motor NP FLA
Motor NP Hertz
Motor NP Power
Motor NP RPM
Motor NP Volts
Motor OL Count
Motor OL Factor
Motor OL Hertz
Motor Poles
Motor Type
Mtr NP Pwr Units
Neg Torque Limit
Notch Filter K
Notch FilterFreq
Output Current
Output Freq
Output Power
Output Powr Fctr
Output Voltage
Overspeed Limit
Param Access Lvl
PI BW Filter
PI Configuration
PI Control
PI Deriv Time
PI Error Meter
PI Fdback Meter
PI Feedback Hi
PI Feedback Lo
PI Feedback Sel
PI Integral Time
PI Lower Limit
PI Output Meter
PI Preload
PI Prop Gain
PI Reference Hi
PI Reference Lo
PI Reference Sel
PI Ref Meter
PI Setpoint
PI Status
PI Upper Limit
Pos Torque Limit
Port Mask Act
Power Loss Mode
Power Loss Time
Power Up Marker
Powerup Delay
Preset Speed X
PWM Frequency
Ramped Speed
Rated Amps
Rated kW
Rated Volts
32
Number
193
55
82
54
81
11
284
296
195
53
412
42
43
45
44
41
220
48
47
49
40
46
437
420
419
3
1
7
8
6
83
196
139
124
125
459
137
136
462
463
128
129
131
138
133
130
460
461
126
135
127
134
132
436
595
184
185
242
167
101-107
151
22
28
26
27
Group
HIM Ref Config
Torq Attributes
Spd Mode & Limits
Torq Attributes
Spd Mode & Limits
Metering
Masks & Owners
Masks & Owners
MOP Config
Torq Attributes
Speed Feedback
Motor Data
Motor Data
Motor Data
Motor Data
Motor Data
Diagnostics
Motor Data
Motor Data
Motor Data
Motor Data
Motor Data
Torq Attributes
Speed Feedback
Speed Feedback
Metering
Metering
Metering
Metering
Metering
Spd Mode & Limits
Drive Memory
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Process PI
Torq Attributes
Security
Power Loss
Power Loss
Faults
Restart Modes
Discrete Speeds
Load Limits
Metering
Drive Data
Drive Data
Drive Data
Parameter Name
Reference Mask
Reference Owner
Regen Power Lim
Reset Meters
Reset To Defalts
Rev Speed Limit
Run Boost
S Curve %
Save HIM Ref
Save MOP Ref
Save To User Set
Shear Pin Time
Skip Freq Band
Skip Frequency X
Sleep Level
Sleep Time
Sleep Wake Mode
Sleep Wake Ref
Slip Comp Gain
Slip RPM @ FLA
Slip RPM Meter
Speed Desired BW
Speed Feedback
Speed Loop Meter
Speed Mode
Speed Reference
Speed Ref Source
Speed Ref X Hi
Speed Ref X Lo
Speed Ref X Sel
Speed /Torque Mod
Start At PowerUp
Start Inhibits
Start Mask
Start Owner
Start/Acc Boost
Status X @ Fault
Stop/Brk Mode X
Stop Owner
SV Boost Filter
TB Man Ref Hi
TB Man Ref Lo
TB Man Ref Sel
Testpoint X Data
Testpoint X Sel
Torq Current Ref
Torque Current
Torque Perf Mode
Torque Ref A Hi
Torque Ref A Lo
Torque Ref A Sel
Torque Setpoint1
Total Inertial
Trim % Setpoint
Trim Hi
Trim In Select
Trim Lo
Trim Out Select
Voltage Class
Wake Level
Wake Time
Write Mask Act
Write Mask Cfg
Number
280
292
153
200
197
454
70
146
192
194
199
189
87
84-86
182
183
178
179
122
121
123
449
25
451
80
23
213
91, 94
92, 95
90, 93
88
168
214
277
289
69
227, 228
155, 156
288
59
97
98
96
235, 237
234, 236
441
4
53
428
429
427
435
450
116
119
117
120
118
202
180
181
597
596
Group
Masks & Owners
Masks & Owners
Load Limits
Drive Memory
Drive Memory
Spd Mode & Limits
Volts per Hertz
Ramp Rates
HIM Ref Config
MOP Config
Drive Memory
Load Limits
Spd Mode & Limits
Spd Mode & Limits
Restart Modes
Restart Modes
Restart Modes
Restart Modes
Slip Comp
Slip Comp
Slip Comp
Speed Regulator
Metering
Speed Regulator
Spd Mode & Limits
Metering
Diagnostics
Speed Reference
Speed Reference
Speed Reference
Spd Mode & Limits
Restart Modes
Diagnostics
Masks & Owners
Masks & Owners
Volts per Hertz
Diagnostics
Stop/Brake Modes
Masks & Owners
Torq Attributes
Speed Reference
Speed Reference
Speed Reference
Diagnostics
Diagnostics
Torq Attributes
Metering
Torq Attributes
Torq Attributes
Torq Attributes
Torq Attributes
Torq Attributes
Speed Regulator
Speed Trim
Speed Trim
Speed Trim
Speed Trim
Speed Trim
Drive Memory
Restart Modes
Restart Modes
Security
Security
Specifications
Approximate Dimensions – PowerFlex 70 Drives
Rating/Frame Size Cross-Reference
Output Power
kW
ND (HD)
Hp
ND (HD)
Frame Size
200-240V
Without
With
Internal
Internal
Filter
Filter
0.37 (0.25)
0.75 (0.55)
1.5 (1.1)
2.2 (1.5)
4.0 (3.0)
5.5 (4.0)
7.5 (5.5)
11 (7.5)
15 (11)
18.5 (15)
22 (18.5)
30 (22)
37 (30)
0.5 (0.33)
1.0 (0.75)
2.0 (1.5)
3.0 (2.0)
5.0 (3.0)
7.5 (5.0)
10 (7.5)
15 (10)
20 (15)
25 (20)
30 (25)
40 (30)
50 (40)
A
A
B
B
–
–
–
–
–
–
–
–
–
B
B
B
B
C
D
D
D
D
D
–
–
–
400-480V
IP66,
Without
NEMA
Internal
Type 4X/12 Filter
With
Internal
Filter
500-600V
IP66,
Without
NEMA
Internal
Type 4X/12 Filter
With
Internal
Filter
IP66,
NEMA
Type 4X/12
B
B
B
B
D
D
D
D
D
D
–
–
–
B
B
B
B
B
C
C
D
D
D
D
E
E
B
B
B
B
B
D
D
D
D
D
D
E
E
–
–
–
–
–
–
–
–
–
–
–
–
–
B
B
B
B
B
D
D
D
D
–
–
–
–
A
A
A
B
B
–
–
–
–
–
–
–
–
A
A
A
B
B
C
C
D
D
–
–
–
–
PowerFlex 70 Frames A-D
IP20/66, NEMA Type 1/4X/12
A
D
Flange Mount
A
C
E
C
B
B
D
F
E
Dimensions are in millimeters and (inches).
Frame
A
IP20, NEMA Type 1
B
C
D
E
F
Drive Weight ➊
kg (lbs.)
A
B
C
D
E
225.7 (8.89)
234.6 (9.24)
300.0 (11.81)
350.0 (13.78)
555.8 (21.88)
179.8 (7.08)
179.8 (7.08)
179.8 (7.08)
179.8 (7.08)
207.1 (8.15)
94.2 (3.71)
122.7 (4.83)
137.6 (5.42)
169.0 (6.65)
200.0 (7.87)
211.6 (8.33)
220.2 (8.67)
285.6 (11.25)
335.6 (13.21)
491.0 (19.33)
5.8 (0.23)
5.8 (0.23)
5.8 (0.23)
5.8 (0.23)
6.9 (0.27)
2.71 (6.0)
3.60 (7.9)
6.89 (15.2)
9.25 (20.4)
18.60 (41.0)
239.8 (9.44)
350.0 (13.78)
555.8 (21.88)
203.3 (8.00)
210.7 (8.29)
219.8 (8.65)
122.7 (4.83)
169.0 (6.65)
200.0 (7.87)
220.2 (8.67)
335.6 (13.21)
491.0 (19.33)
5.8 (0.23)
5.8 (0.23)
6.9 (0.27)
3.61 (8.0)
9.13 (20.1)
18.60 (41.0)
225.8 (8.89)
234.6 (9.24)
300.0 (11.81)
350.0 (13.78)
555.8 (21.88)
178.6 (7.03)
178.6 (7.03)
178.6 (7.03)
178.6 (7.03)
207.1 (8.15)
123.0 (4.84)
123.0 (4.84)
123.0 (4.84)
123.0 (4.84)
117.2 (4.61)
55.6 (2.19)
55.6 (2.19)
55.6 (2.19)
55.6 (2.19)
89.9 (3.54)
–
–
–
–
–
2.71 (6.0)
3.60 (7.9)
6.89 (15.2)
9.25 (20.4)
18.60 (41.0)
122.4 (4.82)
171.7 (6.76)
185.0 (7.28)
219.9 (8.66)
280.3 (11.04)
IP66, NEMA Type 4X/12
B
D
E
171.7 (6.76)
219.9 (8.66)
280.3 (11.04)
Flange Mount
A
B
C
D
E
156.0 (6.14)
205.2 (8.08)
219.0 (8.62)
248.4 (9.78)
280.3 (11.04)
➊ Weights include HIM and Standard I/O.
33
Specifications
Approximate Dimensions – Medium Duty External Dynamic Brake Resistors
Dimensions are in millimeters and (inches).
30.0
(1.18)
17.0
(0.67)
61.0
(2.40)
60.0
(2.36)
31.0
(1.22)
C
US
C
US
59.0
(2.32)
335.0
(13.19)
386.0
(15.20)
ROCKWELL
AUTOMATION
SURFACES MAY BE
AK-R2-091P500
AK-R2-047P500
AK-R2-360P500
17.0
(0.67)
Catalog Number
Ohms
Watts
Frame Size
AK-R2-091P500
AK-R2-047P500
AK-R2-360P500
AK-R2-030P1K2
AK-R2-120P1K2
91
47
360
30
120
86
166
86
260
260
A
A
A
B
B
34
405.0
(15.94)
AUTOMATION
ROCKWELL
316.0
(12.44)
AK-R2-030P1K2
AK-R2-120P1K2
Notes
35
The Allen-Bradley PowerFlex family of AC drives provides a single-source solution for virtually any drive application
requirement ranging from 0.2 to 6,770 kW (0.25 to 8,500 hp). Significant commonality across multiple platforms
including networks, operator interface, programming and hardware make PowerFlex drives easy to start up, operate and
maintain. Multi-lingual programming, operator interface text and voltage-sensitive defaults in PowerFlex drives will help
global OEMs and end-users save time and money during set-up, integration and maintenance of virtually any automation
system.
Rockwell Automation supports drive users whenever and wherever needed, providing drive specialists and manufacturing
expertise for unmatched service and support around the globe. In fact, one of every five Rockwell Automation employees
is in the field with users every day. Rockwell Automation also offers a full spectrum of value-added services and expertise
to help simplify maintenance and enhance productivity.
Rockwell Automation is committed to helping its customers meet ever-changing demands. PowerFlex drives illustrate our
commitment to user productivity through timely delivery of world-class products and continued backward compatibility
to minimize life-cycle costs. Count on Rockwell Automation to be your Complete Automation™ partner – now and in the
future.
For further information on PowerFlex drives visit our web site at: www.abpowerflex.com
PowerFlex, DriveExplorer and DriveTools SP are trademarks of Rockwell Automation.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
www.rockwellautomation.com
Corporate Headquarters
Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201
Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions
Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444
Europe/Middle East/Africa: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640
Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846
Headquarters for Dodge and Reliance Electric Products
Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA, Tel: (1) 864.297.4800, Fax: (1) 864.281.2433
Europe/Middle East/Africa: Rockwell Automation, Herman-Heinrich-Gossen-Strasse 3, 50858 Köln, Germany, Tel: 49 (0) 2234 379410, Fax: 49 (0) 2234 3794164
Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore 307987, Tel: (65) 6356-9077, Fax: (65) 6356-9011
U.S. Allen-Bradley Drives Technical Support
Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, Email: [email protected], Online: www.ab.com/support/abdrives
Publication 20A-TD001G-EN-P — May 2005
Supersedes 20A-TD001F-EN-P — January 2005