Download NETC01-M3 User Manual
Transcript
Details of command When an error has occurred (remote register) 1) Specify the register address number. 2) Check the register address number response. 3) Turn the TRIG from OFF to ON. The selected parameter or operation data is started writing. 4) When the written value is an error, the STATUS is turned from OFF to ON. Check the command code and DATA. 5) Turn the TRIG from ON to OFF, and reset the error status. Note If an error has occurred in data transfer, the STATUS is turned ON. When specifying data that is outside the setting range (write 1000 to the "STOP input action" parameter) [Master to NETC01-M3] (TM+TS)×2 0001h Register address number 0 s or more TRIG 0 s or more (TM+TS)×2 ON OFF 0 s or more 1100h Command code 1000 (03E8h) DATA [NETC01-M3 to master] Register address number response 0001h (TM+TS)×2 STATUS TRIG_R ON OFF ON OFF Command code response DATA response −44− 1100h 1000 (03E8h)