Turbo PMAC Software Reference Ixx81 for MACRO Absolute Position Reads (Ixx91=$720000 - $740000) Addresses are MACRO Node Numbers MACRO Node Number Ixx81 for MACRO IC 0 Ixx81 for MACRO IC 1 Ixx81 for MACRO IC 2 Ixx81 for MACRO IC 3 0 1 4 5 8 9 12 13 $000100 $000001 $000004 $000005 $000008 $000009 $00000C $00000D $000010 $000011 $000014 $000015 $000018 $000019 $00001C $00001D $000020 $000021 $000024 $000025 $000028 $000029 $00002C $00002D $000030 $000031 $000034 $000035 $000038 $000039 $00003C $00003D If obtaining the absolute position through a Delta Tau MACRO Station or equivalent, MACRO Station setup variable MI11x for the matching node must be set properly to obtain the type of information desired. Ixx82 Motor xx Current-Loop Feedback Address Range: $000000 – $FFFFFF Units: Turbo PMAC Y-addresses Default: $0 Ixx82 tells Turbo PMAC which addresses to read to get its current feedback values for Motor xx if Turbo PMAC is closing the current loop for this motor. Turbo PMAC must be performing the commutation for the motor (Ixx01=1) if it is to close the current loop as well. A zero value for Ixx82 tells PMAC not to close the current loop for this motor. In this case, PMAC outputs either one velocity or torque command value (Ixx01 bit 0 = 0), or two phase-current command values (Ixx01 bit 0 = 1), usually represented as analog voltages. A non-zero value for Ixx82 automatically triggers current loop execution in the phase interrupt using the current values found in the registers specified by Ixx82. Typically, these registers are analog-to-digital converter (ADC) registers in a PMAC2-style Servo IC, or MACRO feedback registers containing copies of ADC registers in a MACRO Station. Digital current loop closure on the Turbo PMAC requires a set of three consecutive command output registers. Generally, this requires writing to either a PMAC2-style Servo IC or a MACRO IC. When Ixx01 is set to 1, Turbo PMAC performs the phase commutation for this motor, computing two phase current commands based on the position/velocity servo command and the magnetization current value. If Ixx82>0, these commands are compared to the two actual current values read from the address specified by Ixx82, and the next lower address. It executes a PI filter on the current loops and outputs three voltage command values to the address specified by Ixx02 and the next two higher addresses. These are typically the PWM commands for the three half-bridges of a brushless motor power stage. When the digital current loop is used for drives connected directly to the Turbo PMAC2, the typical values for Ixx82 are: 5-116 Turbo PMAC/PMAC2 I-Variable Specification
Related documents
Clicca qui
ACC-24P2____________________________Axis Expansion
1^ USER MANUAL ^2 Accessory 70E
Descargar - Cummins Engines
ACC-24E2S___________________________Axis Expansion
^1 USER MANUAL ^2 Accessory 24C2A
turbo_pmac_user_manu.. - BICEP 2yr Data Release
DM-170G User Manual
Here - Delta Tau
DM-170G User Manual
^2 Pmac Tuning Pro
to User Manual