Download CIC751 User´s Manual
Transcript
CIC751 Micro Link Interface (MLI) 4.1.4.2 Write Offset and Data Frame A Write Offset and Data Frame are used by the Local Controller to send an address offset and data to the Remote Controller. The Write Offset and Data Frame contains the following parts: • • • • Header: The header starts with Frame Code FC = 00B followed by the Pipe number PN of the Transfer Window that has been the target of the write operation. m-Bits of write offset: These bits define the write offset. The value of m depends on the size of the Remote Window, defined by the Copy Base Address Frame (m = 1-16). Write data field: The write data field can be 8, 16, or 32 bit wide, depending on the data width of the write access to the Transfer Window. Parity bit P. Header 0 1 2 3 4 0 1 PN 12+m m-Bit Offset Address 8-Bit Data P Header 0 1 2 3 4 0 1 PN 20+m m-Bit Offset Address 16-Bit Data P Header 0 1 2 3 4 0 1 PN 36+m m-Bit Offset Address 32-Bit Data P write_offs_data Figure 4-7 Write Offset and Data Frame Details about the Write Offset and Data Frame handling of the CIC751 are provided in Chapter 4.2.1.2. User Manual MLI, V1.0 4-9 V 1.0, 2005-11