Download Please read user manual before use.

Transcript
USER MANUAL
PIM-3012_24C SERIES
MODIFIED SINE WAVE INVERTER WITH CHARGER
V.2.1
WWW.MPPSOLAR.COM
Please read user manual before use.
USEFUL APPLICATIONS
RUN NOTEBOOK COMPUTERS, RADIOS, TVS, VCRS,
LAMPS, FANS, FAX, DRILL, . . . . . . ETC.
PRODUCT SPECIFICATION
INPUT VOLTAGE RANGE : DC 10~15V (12V) // DC 20~30V (24V)
INPUT FULL LOAD CURRENT : 300A (12V) // 150A (24V)
STANDBY INPUT CURRENT : <0.7A (12V) // <0.6A (24V)
OUTPUT VOLTAGE (AC) : 220V~240V
OUTPUT WAVEFORM : MODIFY SINE WAVE
OUTPUT FREQUENCY : 50Hz or 60Hz
CONTINUE OUTPUT POWER : 3000W
PEAK OUTPUT POWER : 6000W
EFFICIENCY : 85~90%
BATTERY LOW PRE-ALARM : 10.5 ± 0.5V (12V) // 21 ± 0.5V (24V)
BATTERY LOW SHUTDOWN : 10 ± 0.5V (12V) // 20 ± 0.5V (24V)
THERMAL PROTECT : 60 ± 5℃(MICROCONTROLLER )
AUTO-OPERATION FAN (TEMPERATURE OR LOAD)
OVER LOAD PROTECT : YES (MICROCONTROLLER )
OUTPUT SHORT PROTECT : YES ( MICROCONTROLLER )
BATTERY EX. 12V / 24V PROTECT : YES ( MICROCONTROLLER )
BATTERY POLARITY PROTECT : YES (BY FUSE )
FUSE : 25A*16PCS (12V) // 15A*16PCS (24V)
TRANSFER TIME : 16m SEC
CHARGER CURRENT : MAX. 10A (12V) // 5A (24V)
DIMENTION ( L*W*H) mm : 420*169*152
WEIGHT : 8.2Kg
REMOTE CONTROL
REMOTE
CONTROL
TERMINAL
AC OUTPUT
(BLACK)
AC
CHARGER
ON
OVER LOAD
OVER TEMP
AC LINE
OUTLET
FAN
NORMAL
LOW BATTERY
AC
AC
FUSE
OUTLET
OFF
POWER SWITCH
O/P:230VAC/50Hz
AC OUTPUT SOCKET
(RED)
TERMINAL
CAUTION : DO NOT REVERSE INPUT. USE RED BATTERY CORD TO CONNECT (+) OF A DC BATTERY TO (+)
TERMINAL. AND THEN, USE BLACK BATTERY CORD TO CONNECT (-) BATTERY TO (-) TERMINAL.
TERMINAL
(BLACK)
AC LINE
FAN
BLACK
RED
AC
FUSE
TERMINAL
(RED)
BATTERY
WARNING SOUND – PRE-ALARM
LOW-BATTERY BI---------BI---------BI
OVER-HEATING BI---BI---BI---BI---BI
OVERLOAD
BI-BI-BI-BI-BI-BI-BI
NORMAL OPERATION
STEP 1: MAKE SURE POWER SWITCH IS “OFF”.
REMOTE
CONTROL
AC OUTPUT
AC
ON
CHARGER
ON
OFF
OVER LOAD
NORMAL
OVER TEMP
OUTLET
LOW BATTERY
AC
OFF
OUTLET
O/P:230VAC/50Hz
STEP 2: WHEN CONNECTED TO ANY APPLIANCE, BE SURE TO TURN ON INVERTER FIRST BEFORE SWITCHING
ON THE POWER OF THE APPLIANCE.
REMOTE
CONTROL
TURN ON
SECONDLY
TURN ON
FIRSTLY
AC OUTPUT
CHARGER OVER LOAD
OVER TEMP
ON
NORMAL LOW BATTERY
AC
OUTLET
OFF
O/P:230VAC/50Hz
CAUTION: WHEN USING THE INVERTER, DO NOT EXCEED ITS MAXIMUM OUTPUT POWER. MAKE SURE THE
TOTAL STARTING POWER CAPACITY DOES NOT EXCEED THE MAXIMUM OUTPUT POWER OF THE INVERTER.
REMOTE
CONTROL
AC OUTPUT
AC
CHARGER OVER LOAD OVER TEMP
ON
OUTLET
NORMAL LOW BATTERY
BATTERY
OFF
O/P:230VAC/50Hz
UPS FUNCTIONALITY
NOTE: IF YOU WANT TO USE THIS UNIT AS AN UPS, TURN ON THE SWITCH OF THE INVERTER AT FIXED
POSITION. WHEN THE BLACKOUT OCCURS, THE INVERTER WILL DIVERT POWER SOURCE AUTOMATICALLY
FROM HOME MAIN TO BATTERY TO PROVIDE POWER TO APPLIANCE.
ON
HOME MAIN
SOCKET
REMOTE
CONTROL
AC OUTPUT
AC
OFF
CHARGER OVER LOAD OVER TEMP
ON
OUTLET
NORMAL LOW BATTERY
BATTERY
OFF
O/P:230VAC/50Hz
CHASSIS EARTH
THE CHASSIS GROUND LUG SHOULD BE CONNECTED TO GROUND. IN A VEHICLE, CONNECT THE GROUND
LUG TO THE CHASSIS OF THE VEHICLE. WHEN IN A BOAT, CONNECT TO THE BOAT’S GROUND SYSTEM. AT A
FIXED LOCATION ON LAND, CONNECT DIRECTLY TO GROUND.
AC LINE
CHASSIS
GROUND
LUG
FAN
AC
FUSE
AC CHARGER
CONNECT AC INPUT POWER CORD TO HOME MAIN SOCKET FIRST, THEN CONNECT INVERTER TO BATTERY BY
MATCHING RED BATTERY WIRE TO POSITIVE TERMINAL (+) OF THE BATTERY AND BLACK BATTERY WIRE TO
NEGATIVE TERMINAL (-) OF THE BATTERY.
HOME MAIN SOCKET
REMOTE
CONTROL
AC OUTPUT
AC
CHARGER
ON
OVER LOAD
NORMAL
OVER TEMP
OUTLET
BATTERY
LOW BATTERY
AC
OUTLET
OFF
O/P:230VAC/50Hz
POWER SWITCH ON
ON
POWER SWITCH OFF
SLOWLY
CHARGING
QUICK
CHARGING
OFF
WARNING
HOME MAIN SOCKET
AC LINE
AC LINE
MAX. 2300W
AC
FUSE
MAX : 10A
FUSE
BATTERY LED ON/OFF INDICATIVE CHART
A
BATTERY
LED
LIGHT
5A
BATTERY
LED
LIGHT
BATTERY
LED
LIGHT
BATTERY
LED
BLINKS
10A
4.5A
9A
4A
8A
3.5A
7A
3A
6A
2.5A
5A
2A
4A
1.5A
3A
1A
2A
0.5A
1A
0A
(24V)
0A
12V
(24V)
12.5V
(25V)
13V
(26V)
13.5V
(27V)
14V
(28V)
14.5V
(29V)
V
0.2(12V)
V
0.4(24V)
:CHARGER CURRENT
LED INDICATORS
NORMAL LED “ON”: POWER ON, INVERTER STANDBY
NORMAL LED “OFF”: POWER OFF
CHARGER LED “ON”: BATTERY CHARGING
CHARGER LED “BLINKING”: FULL BATTERY
AC OUTPUT
REMOTE
CONTROL
CHARGER
NORMAL
AC
CHARGER
ON
OVER LOAD
NORMAL
OVER TEMP
OUTLET
LOW BATTERY
AC
ON
OFF
OUTLET
O/P:230VAC/50Hz
NOTE:
IF TOTAL ENERGY REQUIREMENT EXCEEDS THE OUTPUT CAPACITY OF INVERTER, OR IF AFTER OPERATING
FOR AN EXTENDED PERIOD OF TIME, OR IF THE TEMPERATURE OF INVERTER REACHES 60°C, INVERTER
OUTPUT WILL REDUCE BY THE PROTECTION CIRCUIT.
0
60 C
.
CAUTION
* ALWAYS PLACE THE INVERTER IN
AN ENVIRONMENT WHICH IS :
( A ) WELL VENTILATED
( B ) NOT EXPOSED TO DIRECT
SUNLIGHT OR HEAT SOURCE
( C ) OUT OF REACH FROM CHILDREN
( D ) AWAY FROM WATER/MOISTURE,
OIL OR GREASE
( E ) AWAY FROM ANY FLAMMABLE
SUBSTANCE
WARNING - FLUORESCENT LAMP:
DO NOT USE THIS DEVICE WITH FLUORESCENT LAMPS.
Glow switch
a
AC IN
b
Lamp
Power Factor
Capacitor
BALLASTS