Download Newport 495CC Manual - Artisan Technology Group

Transcript
Artisan Technology Group is your source for quality
new and certified-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
InstraView REMOTE INSPECTION
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specifications, manuals, and documentation
SM
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
Contact us: (888) 88-SOURCE | [email protected] | www.artisantg.com
(M-) 495CC
(M-) 495ACC
Rotation
Stages
USER’S MANUAL
www.newport.com
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
Rotation Stages
Warranty
Newport Corporation warrants this product to be free from defects in
material and workmanship for a period of 1 year from the date of shipment.
If found to be defective during the warranty period, the product will either
be repaired or replaced at Newport’s discretion.
To exercise this warranty, write or call your local Newport representative,
or contact Newport headquarters in Irvine, California. You will be given
prompt assistance and return instructions. Send the instrument, transportation prepaid, to the indicated service facility. Repairs will be made
and the instrument returned, transportation prepaid. Repaired products
are warranted for the balance of the original warranty period, or at least 90
days.
Limitation of Warranty
This warranty does not apply to defects resulting from modification or misuse of any product or part.
CAUTION
Warranty does not apply to damages resulting from:
• Incorrect usage:
– Load on the rotation stage greater than maximum specified load.
– Carriage speed higher than specified speed.
– Improper grounding.
¬ Connectors must be properly secured.
¬ When the load on the rotation stage represents an electrical
risk, it must be connected to ground.
– Excessive or improper cantilever loads.
• Modification of the rotation stage or any part.
This warranty is in lieu of all other warranties, expressed or implied,
including any implied warranty of merchantability or fitness for a particular
use. Newport Corporation shall not be liable for any indirect, special, or
consequential damages.
No part of this manual may be reproduced or copied without the prior written approval of Newport Corporation.
This manual has been provided for information only and product specifications are subject to change without notice. Any changes will be reflected in
future printings.
EDH0194En1010 – 05/03
ii
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
Rotation Stages
Table of Contents
Warranty .................................................................................................................ii
Table of Contents..................................................................................................iii
Warnings .................................................................................................................v
Cautions .................................................................................................................vi
1.0
— Introduction .................................................................................1
2.0
— Description ...................................................................................2
2.1 Design Details ............................................................................................2
3.0
3.1
3.2
3.3
3.4
3.5
4.0
— Characteristics ............................................................................3
Definitions ..................................................................................................3
Mechanical Specifications........................................................................4
Load Specification Definitions.................................................................4
Load Characteristics and Stiffness .........................................................4
Rotation Stage Weights ............................................................................4
— Drive ................................................................................................5
4.1 DC-Servo Drive Version ............................................................................5
5.0
5.1
5.2
5.3
5.4
5.5
6.0
— Motor ...............................................................................................5
UE31CC DC-Motor Characteristics..........................................................5
Command Signals for the DC-Motor .......................................................5
Sensor Position..........................................................................................6
Feedback Signal Position..........................................................................6
Pinouts........................................................................................................7
— Connection to Newport Controllers ................................8
6.1 Warnings on controllers...........................................................................8
6.2 Connection .................................................................................................9
6.3 Cables .........................................................................................................9
7.0
— Connection to Non-Newport Controllers ....................11
8.0
— Disabling of Limit Switches................................................12
9.0
— Dimensions .................................................................................14
iii
EDH0194En1010 – 05/03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
Rotation Stages
10.0 — Maintenance ..............................................................................15
10.1 Maintenance.............................................................................................15
10.2 Repairing ..................................................................................................15
10.3 Calibration................................................................................................15
Service Form .........................................................................................................16
We declare that the accompanying product, identified with the “
all relevant requirements of Directives:
• 73/23/EEC, for Low Voltage Compatibility.
• 89/336/EEC for Electromagnetic Compatibility.
” mark, meets
Generic standard:
Emission:
NF EN61326-1, for measurement, lab and control equipment.
Immunity:
NF EN61326-1, for measurement, lab and control equipment.
Safety:
EIC 1010-1, safety standards for measurement, lab and control
equipment.
Newport Corporation shall not be liable for damages when using the product:
• Modification of the product.
• Using modified connector, or modified or not supplied cables.
• Connecting this product to non-CE equipment.
EDH0194En1010 – 05/03
iv
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
Rotation Stages
Warnings
WARNING
The rotation of objects of all types carries potential risks for operators.
Ensure the protection of operators by prohibiting access to the dangerous
area and by informing the personnel of the potential risks involved.
WARNING
Do not use this stage when its motor is emitting smoke or is unusually
hot to the touch or is emitting any unusual odor or noise or is in any
other abnormal state.
Stop using the stage immediately, switch off the motor power and then
disconnect the electronics power supply.
After checking that smoke is no longer being emitted contact your
Newport service facility and request repairs. Never attempt to repair the
stage yourself as this can be dangerous.
WARNING
Make sure that this stage is not exposed to moisture and that liquid does
not get into the stage.
Nevertheless, if any liquid has entered the stage, switch off the motor
power and then disconnect the electronics from power supply.
Contact your Newport service facility and request repairs.
WARNING
Do not insert or drop objects into this stage, this may cause an electric
shock, or lock the drive.
Do not use this stage if any foreign objects have entered the stage. Switch
off the motor power and then disconnect the electronics power supply.
Contact your Newport service facility for repairs.
WARNING
Do not place this stage in unstable locations such as on a wobbly table or
sloping surface, where it may fall or tip over and cause injury.
If this stage has been dropped or the case has been damaged, switch off
the motor power and then disconnect the electronics power supply.
Contact your Newport service facility and request repairs.
WARNING
Do not attempt to modify this stage; this may cause an electric shock or
downgrade its performance.
WARNING
Do not exceed the usable depth indicated on the mounting holes (see
section “Dimensions”). Longer screws can damage the mechanics or
cause a short-circuit.
v
EDH0194En1010 – 05/03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
Rotation Stages
Cautions
CAUTION
Do not place this stage in a hostile environment such as X-Rays, hard
UV,… or in a vacuum environment less than 10-2 Torr.
CAUTION
Do not place this stage in a location affected by dust, oil fumes or steam.
This may cause an electric shock.
CAUTION
Do not leave this stage in places subject to extremely high temperatures
or low temperatures. This may cause an electric shock.
• Operating temperature: +10 to +35 °C.
• Storage temperature: -10 to +40 °C (in its original packaging).
CAUTION
Do not move this stage if its motor power is on.
Make sure that the cable to the electronics is disconnected before moving the stage. Failure to do so may damage the cable and cause an electrical shock.
CAUTION
Be careful that the stage is not bumped when it is being carried. This
may cause it to malfunction.
CAUTION
When handling this stage, always unplug the equipment from the power
source for safety.
CAUTION
When the carriage is in end-of-run position, it is strongly recommended
not to go beyond this point by using the manual knob as this may damage the stage mechanism.
CAUTION
Contact your Newport service facility to request cleaning and specification control every year.
EDH0194En1010 – 05/03
vi
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
Rotation Stages
Rotation Stages
(M-)495CC/ACC
1.0
Introduction
This manual provides operating instructions for the rotation stage that you
have purchased in the (M-)495CC/ACC Series:
• (M-)495CC
• (M-)495ACC
(M-)495CC and (M-)495ACC rotation stages.
RECOMMENDATION
We recommend you read carefully the chapter “Connection to electronics” before using the (M-)495CC/ACC rotation stage.
1
EDH0194En1010 – 05/03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
2.0
Rotation Stages
Description
The (M-)495CC rotation stages are a cost-effective performance alternative
to the precision (M-)URM100 rotation stages. They employ a lowprofile
design with highly flexible mounting grid for horizontal or vertical mounting.
(M-)495CC stages incorporate a hardened and ground worm compliantly
loaded against a precision cut self-lubricating worm wheel for continuous
smooth travel. Compliant loading minimizes inherent drivetrain backlash,
limiting it to 0.015°. The worm wheel is held in a large diameter crossedroller bearing to minimize wobble and play.
A precision optical encoder is hard mounted to the worm and reads position to 0.001° resolution. Coarse angular readout is provided by a stage
mounted scale graduated in degrees. The (M-)495CC includes limit switches and a home switch. If desired, the limit switches can be disabled to provide continuos 360° rotation.
All (M-)495CC/ACC Series stages are equipped with a knurled knob for a manual control when motor power is off.
The (M-)495ACC version is available with an aperture allowing a light beam
to pass over the stage.
For optimal performance, we recommend the use of our ESP or MM series
motion controllers.
The (M-)495CC/ACC Series rotation stages are supplied with a 3-meter
cable for connection to our motion controllers.
2.1
Design Details
Base Material
Bearings
Drive Mechanism
Worm Gear Ratio
Feedback
Limit Switches
Origin
Motor
1)
EDH0194En1010 – 05/03
Stainless steel with aluminum body
Crossed-roller bearings
Ground worm gear with self compliant preload
1:180
Worm mounted rotary encoder,
2000 pts/rev., index pulse
Optical, at ±170°, can be disabled for continuous 360° rotation (1)
Optical
DC-servo motor UE31CC
See section: “Disabling of Limit Switches”.
2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
3.0
Rotation Stages
Characteristics
3.1
Definitions
Specifications of our products are established in reference to ISO 230 standard part II “Determination of the position, precision and repeatability of
the machine tools with CNC”.
This standard gives the definition of position uncertainty which depends
on the 3 following quantities:
(Absolute) Accuracy
Difference between ideal position and real position.
On-Axis Accuracy
Difference between ideal position and real position after the compensation
of linear error sources.
Linear errors include: cosine errors, inaccuracy of screw or linear scale
pitch, angular deviation at the measuring point (Abbe error) and thermal
expansion effect. All Newport motion electronics can compensate for linear
accuracy errors by step encoder correction.
The relation between absolute accuracy and on-axis accuracy is as follow:
Absolute Accuracy = On-Axis Accuracy + Slope x Travel
Repeatability
Ability of a system to achieve a commanded position over many attempts.
Reversal Value (Hysteresis)
Difference between actual position values obtained for a given target position when approached from opposite directions.
Minimum Incremental Motion (Sensitivity)
Minimum motion that a rotation stage can achieve. Our rotation stages and
our kinematic chain are conceived in such a way that sensitivity is better
than the resolution of the encoder.
Resolution
The smallest motion an encoder fixed to the rotation stage can measure.
Concentricity
Displacement of the geometric center of a rotation stage from the rotation
axis in the plane defined by bearings.
Wobble
Tilt of rotation axis during rotation of a stage.
The testing of on-axis accuracy, repeatability, and reversal error are made systematically with our test equipment in an air-conditioned room (20 °C ±1 °C).
Each rotation stage is tested with a precision optical encoder.
A linear cycle with 21 measures on the travel and 4 cycles in each direction
gives a total of 164 points.
3
EDH0194En1010 – 05/03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
Rotation Stages
3.2
Mechanical Specifications
Travel Range
(°)
Resolution
(°)
Minimum Incremental Motion
(°)
Uni-directional Repeatability
(°)
Reversal Value (Hysteresis)
(°)
Origin Repeatability
(°)
Absolute Accuracy
(°)
Maximum Speed
(°/sec)
Normal Load Capacity
(N)
Wobble
(µrad)
1)
3.3
360 continuous (1)
0.001
0.003
0.006
0.015
0.002
0.05
2.5
250
150
With disabled limit switches, see section: “Disabling of Limit Switches”.
Load Specification Definitions
Normal Load Capacity (Cz)
Maximum load a rotation stage can move while maintaining specifications.
This value is given with speed and acceleration specified for each rotation
stage, and with a load perpendicular to bearings.
Off-Centered Load (Q)
Maximum cantilever-load a rotation stage can move: Q ≤ Cz / (1 + D/44)
D:
Cantilever distance.
3.4
Load Characteristics and Stiffness
Z
D
Cz
kαx
Mz
Q
Cz
kα
Mz
X
3.5
Q:
Cz:
D:
kα:
Mz:
(N)
(µrad/N.m)
(N.m)
250
20
1.8
Off-center load, Q ≤ Cz / (1 + D/44)
Normal center load capacity on bearings
Cantilever distance in mm
Transversal stiffness
Nominal Torque
Rotation Stage Weights
The weights indicated into the below table is an average value for rotation
stages with a typical drive unit installed.
(M-)495CC/ACC
EDH0194En1010 – 05/03
[lb (kg)]
4
4.4 (2)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
4.0
Rotation Stages
Drive
4.1
DC-Servo Drive Version
(M-)495CC/ACC rotation stages are driven with a DC-motor enabling an
angular speed to 2.5 °/sec. These stages offer a cost effective performance
alternative to those who have precision positioning needs with budget limitations.
(M-)495ACC
Performance Specifications
Resolution
(°)
(M-)495CC/ACC
0.001
Speed
(°/sec)
2.5
Motor
UE31CC
(M-)495CC
5.0
Motor
5.1
UE31CC DC-Motor Characteristics
Motor
UE31CC
5.2
Mechanical
Power
(W)
2.53
Nominal
Voltage
(V)
24
Armature
Resistance
(Ω)
57
Inductance
(mH)
1.6
Command Signals for the DC-Motor
+ Motor
+V
– Motor
–V
Displacement
Direction +
Direction +
+ Motor
+V
– Motor
–V
Direction –
Displacement
Direction +
In the above drawings, + Motor signal is referred to – Motor signal.
➊ When the stage moves in + Direction, the + Motor voltage is higher than
– Motor voltage.
➋ When the stage moves in – Direction, the + Motor voltage is lower than
– Motor voltage.
5
EDH0194En1010 – 05/03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
Rotation Stages
5.3
Sensor Position
Home Position (Origin)
at Center of Travel Range
– EOR Limit
+ EOR Limit
Mechanical
Zero
Index Pulse
Index Pulse
Stage Travel Range
Motion
Direction +
End-of-Run and Mechanical Zero are TTL type: 5 V ±5%, 2 mA max.
Use of the Index Pulse provides a repeatable Home Position at ±1 step.
CAUTION
“End-of-Run” and “Mechanical Zero” are active signals and should not be
connected to any other source. Use appropriate TTL type receivers.
5.4
Feedback Signal Position
1
Encoder
Phase A
Encoder
Phase A
Encoder
Phase B
Encoder
Phase B
2
3
4
1
0
1
Direction +
Direction +
0
1
0
1
0
Direction –
Motion
Direction +
The incremental sensor operates following the photoelectric measurement
principle, with a disk including slides. When the sensor shaft turns, the sensor generates square signals in quadrature, sent to pins #19, #20, #23 and
#24 of the 25-pin Sub-D connector.
Newport
Stage
User
Encoder Phase A
Pin #19
Encoder Phase A
Pin #23
Encoder Phase B
Pin #20
Encoder Phase B
Pin #24
Index Pulse Phase I
Pin #15
Index Pulse Phase I
Pin #25
Pin #21
Pin #22
EDH0194En1010 – 05/03
6
Output Signals
+5 V ±5%
150 mA max.
0V
}
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Encoders
& Sensors
Power Supply
(M-)495CC/ACC
Rotation Stages
5.5
Pinouts
The 25-pin Sub-D connection for the (M-)495CC/ACC rotation stages is
given in the following table:
UE31CC:
(M-)495CC/ACC
14
25
1
13
1
N.C.
14
Shield Ground
2
N.C.
15
Index Pulse I
3
N.C.
16
0 V logic
4
N.C.
17
+ End-of-Run
5
+ Motor
18
– End-of-Run
6
+ Motor
19
Encoder Phase A
7
– Motor
20
Encoder Phase B
8
– Motor
21
Encoder Power: +5 V
9
N.C.
22
0 V Encoder
10
N.C.
23
Encoder Phase /A
11
N.C.
24
Encoder Phase /B
12
N.C.
25
Index Pulse /I
13
Mechanical Zero
7
EDH0194En1010 – 05/03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
6.0
Rotation Stages
Connection to Newport Controllers
6.1
Warnings on controllers
Controllers are intended for use by qualified personnel who recognize
shock hazards and are familiar with safety precautions required to avoid
possible injury. Read the controller user’s manual carefully before operating the instrument and pay attention to all written warnings and cautions.
WARNING
Disconnect the power plug under the following circumstances:
• If the power cord or any attached cables are frayed or damaged in
any way.
• If the power plug is damaged in any way.
• If the unit is exposed to rain, excessive moisture, or liquids are spilled
on the unit.
• If the unit has been dropped or the case is damaged.
• If you suspect service or repair is required.
• Whenever you clean the electronics unit.
CAUTION
To protect the unit from damage, be sure to:
• Keep all air vents free of dirt and dust.
• Keep all liquids away from the unit.
• Do not expose the unit to excessive moisture (>85% humidity).
• Read this manual before using the unit for the first time.
WARNING
All attachment plug receptacles in the vicinity of this unit are to be of the
grounding type and properly polarized.
Contact your electrician to check your receptacles.
WARNING
This product is equipped with a 3-wire grounding type plug.
Any interruption of the grounding connection can create an electric
shock hazard.
If you are unable to insert the plug into your wall plug receptacle, contact your electrician to perform the necessary alterations to ensure that
the green (green-yellow) wire is attached to earth ground.
WARNING
This product operates with voltages that can be lethal.
Pushing objects of any kind into cabinet slots or holes, or spilling any
liquid on the product, may touch hazardous voltage points or short out
parts.
EDH0194En1010 – 05/03
8
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
Rotation Stages
6.2
Connection
On each rotation stage is represented a label which indicates its name, its
serial number and the motor it is equipped with (ex.: UE31PP).
M-495ACC
S/N#
ENCODER:5V MOTOR:UE31CC
DC Motor U=30VDC I=1A
WARNING
Always turn the controller's power OFF before connecting to a stage.
Rotation stages may be connected to the rear panel motor connectors
labeled “Motor…” any time prior to power-up with the supplied cable
assemblies.
WARNING
With MM series controllers, damage to rotation stage may occur if the
rotation stage is not the same type as shown on driver label located near
the rotation stage interface connector.
Check that the option number specified on this label correspond to the
number indicated in the driver module options table for your rotation
stage.
6.3
Cables
Our (M-)495CC/ACC rotation stages are delivered equipped with a 3-meter
cable with 25-pin Sub-D connectors so they can be directly connected to
our controllers/drivers of MM or ESP series.
Dimensions in inches (millimeters)
Locking
Knobs
ø .41
(ø 10.3)
25-Pin Sub-D
Connector
2.13
(54)
2.32 (59)
Disconnected
4.1 (104) for a static cable
6.54 (166) for a cable in motion with the stage
WARNING
This cable is shielded correctly. For a correct operation, make sure to
lock connectors (ground continuity provided by the cable).
For applications where the standard 3-meter cable (MMCABLE-3) included
with your rotation stage is not adequate, Newport offers longer length
cables designed to ensure the integrity of your positioning application.
9
EDH0194En1010 – 05/03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
Rotation Stages
These cables are specially shielded and terminated with Newport’s standard 25-pin sub-D connectors. They are available in 5-m (MMCABLE-5), 7-m
(MMCABLE-7) or 10-m (MMCABLE-10) lengths.
WARNING
Keep the motor cables at a safe distance from other electrical cables in
your environment to avoid potential cross talk.
For cable lengths in excess of 3 meters, we recommend the MMCABLE-REG
to ensure a high quality, regulated 5 V supply to the rotation stages.
Dimensions in inches (millimeters)
25-Pin Sub-D
Male
25-Pin Sub-D
Female
2.1
(54)
2.4 (62)
This regulator is available as an option. Please note that for best efficiency,
this regulator should be attached to the stage to re-adjust the 5 volts coming from the controller through the long cable.
EDH0194En1010 – 05/03
10
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
7.0
Rotation Stages
Connection to Non-Newport Controllers
WARNING
Newport takes no responsibility for improper functioning or damage of a
rotation stage when it is used with any non- Newport controllers.
WARNING
Newport guarantees the “ ” compliance of the (M-)495CC/ACC rotation
stages only if they are used with Newport cables and controllers.
Nevertheless, the figure below indicates the recommended wiring when
a (M-)495CC/ACC rotation stage is used with non-Newport controllers.
Sub-D25 male
Connector
Connection
(M-)495CC/ACC
9
10
11
12
N.C.
N.C.
N.C.
N.C.
1
2
3
4
N.C.
N.C.
N.C.
N.C.
5
6
7
8
+ Motor
+ Motor
– Motor
– Motor
14
Ground
16
13
19
23
20
24
15
25
17
18
21
22
Connector
Cap
0 V logic
Mechanical Zero (*)
Encoder Phase A
Encoder Phase /A
Encoder Phase B
Encoder Phase /B
Index Pulse I
Index Pulse /I
+ End-of-Run (*)
– End-of-Run (*)
+5 V Encoder
0 V Encoder
Connector
Cap
* Open collector type with a 5.6 V protective Zener diode.
End-of-Run or Mechanical Zero:
Max. Iin: 16 mA
Max. V: 5.6 V
Newport
Stage
5.6 V
If the “Mechanical Zero” output is not used, a 1 kΩ/0.25 W resistor must
be connected between pins #13 and #21.
“Encoder” and “Index Pulse” are “differential pair” type output signals.
Using these signals permits a high immunity to noise. Emission circuits
generally used by Newport are 26LS31 or MC3487. Reception circuits to use
are 26LS32 or MC3486.
11
EDH0194En1010 – 05/03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
8.0
Rotation Stages
Disabling of Limit Switches
All (M-)495CC/ACC stages are equipped with ±170° optical limit switches.
These limit switches can be disabled for continuous 360° rotation.
REMARK
To inhibit limit switches, you have to add a jumper on an electrical component. Contact your Newport service facility and order this jumper with
the reference AM1D-200-40-3.7-G.
➊ Note the graduated limb position towards the index located on the body
of the rotation stage.
➋ Unscrew 8 CHc M3 screws fixing the graduated limb, and remove it.
270
280
60
290
50
300
40
310
EDH0194En1010 – 05/03
30
320
330
340
350
0
10
20
12
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
Rotation Stages
➌ On the 2-pin component, add the jumper you ordered with the reference
AM1D-200-40-3.7-G.
➍ Reassemble with 8 CHc M3 screws the graduated limb at ±0.2° of its previous position.
CAUTION
While you reassemble the graduated limb, make sure it is in the same
position as it was before disassembling. It is very important to find again
the zero position on the index and to reach the Index Pulse home position.
13
EDH0194En1010 – 05/03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC/ACC
9.0
Rotation Stages
Dimensions
(M-)495CC
(M-)495ACC
4 HOLES,
4 HOLES,
M4 THD,
THD A,
63
mm SPACING
/
/ C SPACING
4 HOLES,
4 HOLES,
M4 THD,
THD A,
63
mm SPACING
/ C SPACING /
2 HOLES,
THD A CLR,
B SPACING
4 HOLES
THD A CLR,
/ D x C SPACING
4 HOLES, THD A,
/ B SPACING
3 HOLES,
THD A CLR,
C
/ x D SPACING
3 HOLES,
THD A CLR,
/ C x D SPACING
4.5 (114.4)
4 HOLES
THD A, B SPACING
4.5 (114.4)
4 HOLES
THD A, B SPACING
.645 (16.4)
.645 (16.4)
3 HOLES, THD A,
/ D x E SPACING
4 HOLES, THD A,
/ E x D SPACING
1.38
(35.0)
3 HOLES,
THD A,
B SPACING
4 HOLES
THD A CLR,
/ D x C SPACING
3 HOLES, THD A,
/ D x E SPACING
.645
(16.4)
4 HOLES, THD A,
/ E x D SPACING
1.38
(35.0)
3 HOLES,
THD A,
B SPACING
4.5
(114.4)
2.40
(61.0)
4.19
(106.5)
2.07
(52.5)
3 HOLES,
THD A,
B SPACING
4.5
(114.4)
2.40
(61.0)
ø1.97 (50.0) 4 HOLES, M4 THD,
/ 63 mm SPACING
Model (Metric)
495CC
(M-495CC)
495ACC
(M-495ACC)
EDH0194En1010 – 05/03
ø3.94
(100)
4.19
(106.5)
Thread
A
B
1/4-20 1.000
(M6) (25.0)
1/4-20 1.000
(M6) (25.0)
14
.645
(16.4)
2.07
(52.5)
4 HOLES, M4 THD,
/ 63 mm SPACING
Dimension [in. (mm)]
C
D
E
2.000 4.000 3.000
(50.0) (100.0) (75.0)
2.000 4.000 3.000
(50.0) (100.0) (75.0)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
ø3.94
(100)
(M-)495CC/ACC
10.0
Rotation Stages
Maintenance
RECOMMENDATION
It is recommended to contact our After Sales Service which will be able
to define the appropriate maintenance for your application.
10.1
Maintenance
The (M-)495CC/ACC rotation stage requires no particular maintenance.
Nevertheless, this is a precision mechanical device that must be kept and
manipulated with precaution.
PRECAUTIONS
The (M-)495CC/ACC rotation stage must operate, and be stocked in a
clean environment, without dust, humidity, solvents or other substances.
RECOMMENDATION
It is recommended to return your rotation stage to our After Sales
Service after every 2000 hours of use for lubrication.
If your (M-)495CC/ACC rotation stage is mounted on a workstation and
cannot be easily dismantled, please contact our After Sales Service for
further instructions.
10.2
Repairing
CAUTION
Never attempt to disassemble an element of the rotation stage that has
not been specified in this manual.
Disassembling a non specified element can cause a malfunction of the
rotation stage.
If you observe a malfunction in your rotation stage, please immediately
contact us to make arrangements for a repair.
CAUTION
All disassembly attempts or repair of rotation stage without authorization will void your warranty.
10.3
Calibration
CAUTION
It is recommended to return your rotation stage to Newport once a year
for a recalibration to its original specifications.
15
EDH0194En1010 – 05/03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Service Form
Your Local Representative
Tel.:
Fax:
Name:
Return authorization #:
(Please obtain prior to return of item)
Company:
Address:
Date:
Country:
Phone Number:
P.O. Number:
Fax Number:
Item(s) Being Returned:
Model #:
Serial #:
Description:
Reasons of return of goods (please list any specific problems):
EDH0194En1010 – 05/03
16
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(M-)495CC
(M-)495ACC
Rotation Stages
CE Declaration of Conformity
We declare that the accompanying product, identified with the
“ ” mark, meets all relevant requirements of Directive:
• 73/23/CEE, for Low Voltage Compatibility.
• 89/336/EEC for Electromagnetic Compatibility.
Compliance was demonstrated to the following specifications:
EMISSION:
Radiated and Conducted Emission in accordance with
relative prescription to the EMC, NF EN61326-1: Standards
for measurement, lab and control equipment.
IMMUNITY:
Radiated and Conducted Immunity in accordance with
relative prescription to the EMC, NF EN61326-1: Standards
for measurement, lab and control equipment.
SAFETY:
CEI 1010-1, safety standards for measurement, lab and
control equipment.
Jean-Marc DELAHAYE
Quality Director
Zone Industrielle
45340 Beaune-la-Rolande, France
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Artisan Technology Group is your source for quality
new and certified-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
InstraView REMOTE INSPECTION
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specifications, manuals, and documentation
SM
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
Contact us: (888) 88-SOURCE | [email protected] | www.artisantg.com