Download User Manual
Transcript
User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 1 di 19 Industrial Electronic Devices User Manual Revision 1.010 English Software M-Bus Concentrator End User ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 2 di 19 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS INDEX THE SOFTWARE INSTALLATION USE OF CONCENTRATOR M-BUS END USER - CONNECT - SET DATE TIME - GET DATA - NEW SCAN - SET PASSWORD - LANGUAGE CSV FILE WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY PRODUCTS AND RELATED DOCUMENTS UPDATED DOCUMENTATION: Page 2 2 2 2 2 3 3 3 3 6 7 8 9 10 11 19 19 19 Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: Updated Related to the product you own To obtain the most recently updated document, note the “document code” that appears at the top right-hand corner of each page of this document. With this “Document Code” go to web page www.adfweb.com/download/ and search for the corresponding code on the page. Click on the proper “Document Code” and download the updates. To obtain the updated documentation for the product that you own, note the “Document Code” (Abbreviated written "Doc. Code" on the label on the product) and download the updated from our web site www.adfweb.com/download/ REVISION LIST: Revision Date Author Chapter Description 1.000 1.010 04/10/2010 01/02/2012 Fl Fl All All First release version (1.000) Software changed (1.100) WARNING: ADFweb.com reserves the right to change information in this manual about our product without warning. ADFweb.com is not responsible for any error this manual may contain. TRADEMARKS: All trademarks mentioned in this document belong to their respective owners. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 3 di 19 Industrial Electronic Devices THE SOFTWARE: To obtain the software please go to www.adfweb.com/download/filefold/MBus_Concentrator_EU.zip. (This manual is referenced to the last version of the software present on our web site). The software works with MSWindows (MS 2000, XP, Vista, Seven). INSTALLATION: Extract the file downloaded from our web site and follow the procedure to install the software. USE OF CONCENTRATOR M-BUS END USER: - CONNECT: In the main window of the Software (Fig. 1) it is possible to select the type of connection to use for communicate with the HD67054M-xxx (Serial/Modem) and HD67057-B2-xxx (Ethernet). When using the “HD67054M-xxx” it is necessary to select the COM port to use for the communication (“Select COM port”) and then select the connection type between “Direct Connection” if the Concentrator is directly connected to the PC or “Modem Connection” if is used a Dial-UP Modem or GSM Modem. When using the “HD67057-B2-xxx” it is necessary to insert the “IP Address” and the “Port” and then select “TCP Connection” if the Concentrator was programmed for communicate over TCP or “UDP Connection” if the Concentrator was programmed for communicate over UDP. Fig. 1: Main window for “Concentrator M-Bus End User” Software ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 4 di 19 Industrial Electronic Devices If “Modem Connection” is selected from the Main Window of the Software (Fig. 1) the window “Phone Number” appears (Fig. 2). In the field “Insert Phone number” it is necessary to insert the phone number of the modem at the Gateway side. When you have insert the phone number the button “Send” must be pressed. In about 30 seconds the gateway makes the connection to the remote modem. When the connection is established a green string appear in the bottom left side of the window. If the connection isn’t established a red string appear. Fig. 2: “Phone Number” window ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 5 di 19 Industrial Electronic Devices When the connection is performed or when the “Direct Connection” / “TCP Connection” / “UDP Connection” was selected appears the “Password” window (Fig. 3). In the field “Insert the password” it is necessary to insert the Password for use the other functions of the Concentrator and press the “Send” button. There is a Default Password: 0123456789 that were used when the product is tested in the factory. Then it is possible to change that password with this Software. It is possible to insert the wrong password for two times. At the third one it will necessary to wait ten minutes before insert it another time. Fig. 3: “Password” window ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 6 di 19 Industrial Electronic Devices - SET DATE TIME By pressing the “Set Data Time” button from the main window of the software the “Date Time” window appears (Fig. 4). In this section it is possible to read the current data that is used in the Concentrator by pressing the “Read data Time” button. If it is necessary to insert a new data it is possible to fill the fields “Year”, “Month”, “Day”, “Hour”, “Minute”, “Second” manually or pressing the ”Use System Date Time” these field will automatically filled with the Date/Time of your Operating System. Then it is necessary to press the “Write Date Time” button for upload the date/time on the Concentrator. Fig. 4: “Date Time” window ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 7 di 19 Industrial Electronic Devices - GET DATA By pressing the “Get Data” button from the main window of the software the “Get Data” window appears (Fig. 5). This part is used for download the last .csv file saved into the Concentrator. For doing this the “Get Data” button must be pressed. For save the data the button “Save .cvs” must be pressed. Fig. 5: “Get Data” window ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 8 di 19 Industrial Electronic Devices - NEW SCAN By pressing the “New Scan” button from the main window of the software the “New Scan” window appears (Fig. 6). This part is used for send to the Concentrator the command for doing a new scan immediately. For doing this it is necessary to press the “Scan Now” button. If the command is executed with success in the bottom left corner of the window appear the green string “OK”. Otherwise a red string appear. Fig. 6: “New Scan” window ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 9 di 19 Industrial Electronic Devices - SET PASSWORD By pressing the “Set Password” button from the main window of the software the “Set Password” window appears (Fig. 7). If it is necessary to change the Default Password with another one, it is possible to do it in this section. In the two fields it is necessary to insert two times the same new password and then press the “Set New Password” button. Fig. 7: “Set password” window ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 10 di 19 Industrial Electronic Devices - LANGUAGE By pressing the “Language” button from the main window of the software the “Select Language” window appears (Fig. 8). It is possible to select the language from these: English; Italian; German; French; Spanish. Fig. 8: “Select language” window ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 11 di 19 Industrial Electronic Devices CSV FILE When the file is downloaded and opened in a table there are two codes that identify what the number is referred to. At right side you can find an example of file. A: In this field you find the “Title” that you have defined in the compositor; B: This is the date and time of the last scan; C: If in the compositor you have select “M-Bus Node Data” here you can find the “User”; D: If in the compositor you have select “M-Bus Node Data” here you can find the “Scale”; E: If in the compositor you have select “M-Bus Node Data” here you can find the “Floor”; F: If in the compositor you have select “M-Bus Node Data” here you can find the “Flat”; G: This is the Primary Address of the M-Bus Slave Device; H: This is the number of variables defined in the compositor; I: This is the value read of the variable; J: This is the “First Code”. It identify the type of data. For decoded it see “First Code” subsection; K: This is the “Second Code”. Is in addition and complete the information given by the “First Code”. For decoded it see “Second Code” subsection; L: If in the compositor you have select “M-Bus Node Description” here you can find the “Description”. ADFweb.com Srl – IT31010 – Mareno – Treviso Figure 8: Example of CSV file INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 12 di 19 Industrial Electronic Devices FIRST CODE: 31: 32: Mass kg (*103) Mass kg (*104) 33: 34: 35: 36: On On On On 37: 38: 39: 40: Operating Operating Operating Operating 0: Null 1: 2: 3: 4: 5: 6: 7: 8: Energy Energy Energy Energy Energy Energy Energy Energy [Wh] [Wh] [Wh] [Wh] [Wh] [Wh] [Wh] [Wh] 9: 10: 11: 12: 13: 14: 15: 16: Energy Energy Energy Energy Energy Energy Energy Energy [J] [J] [J] [J] [J] [J] [J] [J] (*100) (*101) (*102) (*103) (*104) (*105) (*106) (*107) 41: 42: 43: 44: 45: 46: 47: 48: Power Power Power Power Power Power Power Power W W W W W W W W 17: 18: 19: 20: 21: 22: 23: 24: Volume Volume Volume Volume Volume Volume Volume Volume m3 m3 m3 m3 m3 m3 m3 m3 (*10-6) (*10-5) (*10-4) (*10-3) (*10-2) (*10-1) (*100) (*101) 49: 50: 51: 52: 53: 54: 55: Power Power Power Power Power Power Power J/h J/h J/h J/h J/h J/h J/h 56: Power J/h (*107) 57: 58: 59: 60: 61: Volume Volume Volume Volume Volume 25: 26: 27: 28: 29: 30: Mass Mass Mass Mass Mass Mass kg kg kg kg kg kg (*10-3) (*10-2) (*10-1) (*100) (*101) (*102) (*103) (*104) -3 (*10 ) (*10-2) (*10-1) (*100) (*101) (*102) ADFweb.com Srl – IT31010 – Mareno – Treviso Time: Time: Time: Time: Seconds Minutes Hours Days Time: Time: Time: Time: Seconds Minutes Hours Days (*10-3) (*10-2) (*10-1) (*100) (*101) (*102) (*103) (*104) (*100) (*101) (*102) (*103) (*104) (*105) (*106) Flow Flow Flow Flow Flow m3/h m3/h m3/h m3/h m3/h (*10-6) (*10-5) (*10-4) (*10-3) (*10-2) INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 13 di 19 Industrial Electronic Devices 62: 63: 64: Volume Flow m3/h (*10-1) Volume Flow m3/h (*100) Volume Flow m3/h (*101) 3 -7 65: 66: 67: 68: 69: 70: 71: 72: Volume Volume Volume Volume Volume Volume Volume Volume Flow Flow Flow Flow Flow Flow Flow Flow ext. m /min (*10 ) m3/min (*10-6) m3/min (*10-5) m3/min (*10-4) m3/min (*10-3) m3/min (*10-2) m3/min (*101) m3/min (*100) 73: 74: 75: 76: 77: 78: 79: 80: Volume Volume Volume Volume Volume Volume Volume Volume Flow Flow Flow Flow Flow Flow Flow Flow ext. m3/s (*10-9) m3/s (*10-8) m3/s (*10-7) m3/s (*10-6) m3/s (*10-5) m3/s (*10-4) m3/s (*10-3) m3/s (*10-2) 81: 82: 83: 84: 85: 86: 87: Mass Mass Mass Mass Mass Mass Mass 88: Mass Flow kg/h (*104) 89: 90: 91: 92: Flow Flow Flow Flow Flow Flow Flow Flow Flow Flow Flow kg/h kg/h kg/h kg/h kg/h kg/h kg/h (*10-3) (*10-2) (*10-1) (*100) (*101) (*102) (*103) Temperature Temperature Temperature Temperature [°C] [°C] [°C] [°C] (*10-3) (*10-2) (*10-1) (*100) ADFweb.com Srl – IT31010 – Mareno – Treviso 93: 94: Return Temperature [°C] (*10-3) Return Temperature [°C] (*10-2) 95: 96: Return Temperature [°C] (*10-1) Return Temperature [°C] (*100) 97: 98: 99: 100: Temperature Temperature Temperature Temperature 101: 102: 103: 104: External External External External Temperature Temperature Temperature Temperature 105: 106: 107: 108: Pressure Pressure Pressure Pressure [bar] [bar] [bar] [bar] 109: 110: Time Point: Date Time Point: Time & Date 111: 112: 113: 114: Averaging Averaging Averaging Averaging 115: Actually Duration: Seconds 116: 117: 118: Actually Duration: Minutes Actually Duration: Hours Actually Duration: Days 119: 120: Credit of 10-3 of the nominal local legal currency units Credit of 10-2 of the nominal local legal currency units Difference Difference Difference Difference [K] [K] [K] [K] [°C] [°C] [°C] [°C] (*10-3) (*10-2) (*10-1) (*100) (*10-3) (*10-2) (*10-1) (*100) (*10-3) (*10-2) (*10-1) (*100) Duration: Duration: Duration: Duration: Seconds Minutes Hours Days INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 14 di 19 Industrial Electronic Devices 121: 122: Credit of 10-1 of the nominal local legal currency units Credit of 100 of the nominal local legal currency units 154: 155: Storage interval [hours] Storage interval [days] 123: Debit of 10-3 of the nominal local legal currency units 156: 157. Storage interval month(s) Storage interval year(s) 124: 125: 126: Debit of 10-2 of the nominal local legal currency units Debit of 10-1 of the nominal local legal currency units Debit of 100 of the nominal local legal currency units 127: 128: 129: 130: 131: 132: 133: 134: 135: 136: 137: 138: 139: 140: 141. 142. 143: 144: 145. 146. 147: 148: Access Number (transmission count) Medium (as in fixed header) Manufacturer (as in fixed header) Parameter set identification Model/Version Hardware version # Firmware version # Software version # Customer Location Customer Access Code User Access Code Operator Access Code System Operator Access Code Developer Password Error flags (binary) Error mask Digital Output (binary) Digital Input (binary) Baudrate [Baud] response delay time [bittimes] Retry 158: 159: 160: 161: Duration Duration Duration Duration 162: Start (date/time) of tariff 163: 164: 165: Duration of tariff [minutes] Duration of tariff [hours] Duration of tariff [days] 166: 167: 168: 169: Period Period Period Period 170: 171: 172: Period of tariff months(s) Period of tariff year(s) dimensionless/ no VIF 173: 174: 175: 176: 177: 10-9 Volts 10-8 Volts 10-7 Volts 10-6 Volts 10-5 Volts 149: 150: 151. 152: 153: First storage # for cyclic storage Last storage # for cyclic storage Size of storage block Storage interval [seconds] Storage interval [minutes] 178: 179: 180: 181: 10-4 Volts 10-3 Volts 10-2 Volts 10-1 Volts ADFweb.com Srl – IT31010 – Mareno – Treviso since since since since of of of of tariff tariff tariff tariff last last last last readout[seconds] readout[minutes] readout[hours] readout[days] [seconds] [minutes] [hours] [days] INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 15 di 19 Industrial Electronic Devices 182: 183: 184: 185: 186: 187: 188: 100 Volts 101 Volts 102 Volts 103 Volts 104 Volts 105 Volts 106 Volts 215: 216: Duration since last comulation [months] Duration since last comulation [years] 217: 218: 219: 220: Operation Operation Operation Operation 189: 190: 191: 192: 193: 194: 195: 196: 197: 198: 199: 200: 201: 202: 203: 204: 10-12 Ampere 10-11 Ampere 10-10 Ampere 10-9 Ampere 10-8 Ampere 10-7 Ampere 10-6 Ampere 10-5 Ampere 10-4 Ampere 10-3 Ampere 10-2 Ampere 10-1 Ampere 100 Ampere 101 Ampere 102 Ampere 103 Ampere 221: Date and time of battery change 222: 223: Energy [MWh] (*10-1) Energy [MWh] (*100) 224: 225: Energy [GJ] (*10-1) Energy [GJ] (*100) 226: 227: Volume [m3] (*102) Volume [m3] (*103) 228: 229: Mass [t] (*102) Mass [t] (*103) 205: 206: 207: 208: 209: 210: 211: Reset counter Comulation counter Control signal Day of week Week number Time point of day change State of parameter activation 230: 231: 232: 233: 234: 235: Volume Volume Volume Volume Volume Volume 236: 237: Power [MW] (*10-1) Power [MW] (*100) 238: 239: Power [GJ/h] (*10-1) Power [GJ/h] (*100) 240: 241: Flow Temperature [°F] (*10-3) Flow Temperature [°F] (*10-2) 212: 213: 214: Special supplier information Duration since last comulation [hours] Duration since last comulation [days] ADFweb.com Srl – IT31010 – Mareno – Treviso time time time time battery battery battery battery [hours] [days] [months] [years] 0,1 feet^3 0,1 american gallon 1 american gallon flow 0,001 american gallon/min flow 1 american gallon/min flow 1 american gallon/h INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 16 di 19 Industrial Electronic Devices 242: 243: Flow Temperature [°F] (*10-1) Flow Temperature [°F] (*100) 244: 245: 246: 247: Return Return Return Return 248: 249: Temperature Difference [°F] (*10-3) Temperature Difference [°F] (*10-2) 250: 251: Temperature Difference [°F] (*10-1) Temperature Difference [°F] (*100) 252: 253: 254: 255: External External External External 256: 257: 258: 259: Cold/Warm Cold/Warm Cold/Warm Cold/Warm Temperature Temperature Temperature Temperature Limit Limit Limit Limit [°F] [°F] [°F] [°F] (*10-3) (*10-2) (*10-1) (*100) 260: 261: 262: 263: Cold/Worm Cold/Worm Cold/Worm Cold/Worm Temperature Temperature Temperature Temperature Limit Limit Limit Limit [°C] [°C] [°C] [°C] (*10-3) (*10-2) (*10-1) (*100) 264: 265: 266: 267: 268: 269: Cumul. Cumul. Cumul. Cumul. Cumul. Cumul. Temperature Temperature Temperature Temperature [°F] [°F] [°F] [°F] Temperature Temperature Temperature Temperature count count count count count count max max max max max max (*10-3) (*10-2) (*10-1) (*100) [°F] [°F] [°F] [°F] power power power power power power 270: 271: Cumul. count max power [W] (*103) Cumul. count max power [W] (*104) 272÷299: Empty (*10-3) (*10-2) (*10-1) (*100) [W] [W] [W] [W] [W] [W] (*10-3) (*10-2) (*10-1) (*100) (*101) (*102) ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 17 di 19 Industrial Electronic Devices SECOND CODE: 0: Null 300: 301: 302: 303: 304: 305: 306: 307: 308: 309: 310: 311: 312: 313: 314: 315: 316: 317: 318: 319: 320: 321: 322: 323: 324: 325: 326: 327: 328: 329: 330: 331: 332: per second per minute per hour per day per week per month per year per revolution/measurement increment per input pulse on input channel 0 increment per input pulse on input channel 1 increment per output pulse on output channel 0 increment per output pulse on output channel 1 per liter per m3 per kg per K (Kelvin) per kWh per GJ per kW per (K*l)(Kelvin*liter) per V (Volt) per A (Ampere) multiplied by sek multiplied by sek/V multiplied by sek/A start date(/time) of VIF contains uncorrected unit instead of corrected unit Accumulation only if positive contributions Accumulation of abs value only if negative contributions upper limit value lower limit value # of exceeds of upper limit # of exceeds of lower limit ADFweb.com Srl – IT31010 – Mareno – Treviso 333: 334: 335: 336: 337: 338: 339: 340: Date(/time) Date(/time) Date(/time) Date(/time) Date(/time) Date(/time) Date(/time) Date(/time) of of of of of of of of begin of first lower limit exceed end of first lower limit exceed begin of last lower limit exceed end of last lower limit exceed begin of first upper limit exceed end of first upper limit exceed begin of last upper limit exceed end of last upper limit exceed 341: 342: 343: 344: 345: 346: 347: 348: 349: 350: 351: 352: 353: 354: 355: 356: Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration of of of of of of of of of of of of of of of of limit limit limit limit limit limit limit limit limit limit limit limit limit limit limit limit 357: 358: 359: 360: 361: 362: 363: 364: Duration Duration Duration Duration Duration Duration Duration Duration of of of of of of of of first/last first/last first/last first/last first/last first/last first/last first/last 365: 366: Date(/time) of first/last begin/end Date(/time) of first/last begin/end exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 18 di 19 Industrial Electronic Devices 367: 368: Date(/time) of first/last begin/end Date(/time) of first/last begin/end 369: 370: 371: 372: 373: 374: 375: 376: 377: 378: 379: 380: Multiplicative correction factor (*10-6) Multiplicative correction factor (*10-5) Multiplicative correction factor (*10-4) Multiplicative correction factor (*10-3) Multiplicative correction factor (*10-2) Multiplicative correction factor (*10-1) Multiplicative correction factor (*100) Multiplicative correction factor (*101) Additive correction constant * unit of VIF Additive correction constant * unit of VIF Additive correction constant * unit of VIF Additive correction constant * unit of VIF 381: 382: 383: Multiplicative correction factor: 103 future value next VIFE's and data of this block are manufacturer specific ADFweb.com Srl – IT31010 – Mareno – Treviso (offset) (offset) (offset) (offset) 384: 385: 386: 387: 388: 389: 390: 391: 392: 393: 394: 395: 396: 397: 398: 399: 400: 401: None Too many DIFE's Storage number not implemented Unit number not implemented Tariff number not implemented Function not implemented Data class not implemented Data size not implemented Too many VIFE's Illegal VIF-Group Illegal VIF-Exponent VIF/DIF mismatch Unimplemented action No data available (undefined value) Data overflow Data underflow Data error Premature end of record INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus Concentrator End User Document code: -------- Revision 1.010 Pagina 19 di 19 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address [email protected] RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: 1) Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com. Together with the request, you need to provide detailed information about the problem. 2) Send the product to the address provided with the PRN, having prepaid the shipping costs (shipment costs billed to us will not be accepted). If the product is within the warranty of twelve months, it will be repaired or exchanged and returned within three weeks. If the product is no longer under warranty, you will receive a repair estimate. PRODUCTS AND RELATED DOCUMENTS: Part Description URL HD67031 Analyzer / Scanner / Sniffer M-Bus www.adfweb.com?product=HD67031 HD67120 Converter Ethernet to RS232/RS485 www.adfweb.com?product=HD67120 HD67119 Converter USB 2.0 to RS485 Isolated www.adfweb.com?product=HD67119 HD67507 Gateway Modbus TCP Server to RTU Master www.adfweb.com?product=HD67507 HD67510 Gateway Modbus TCP Client to RTU Slave www.adfweb.com?product=HD67510 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31