Stylish Thermostats For Modern Living
Domestic Heating Control Systems
Dial Type Thermostats
Stylish Dial Type Thermostats
These thermostats are used in conjunction with a separate programmer.
Headline
Information
Product
Ranges
Key
Features
Mounting Type
Flush Mount with Set Back
Function - DS-SB
1 Model, suitable for
radiator and water
Set Back Function
Standard dial thermostats are
either on or off according to the
time clock controlling the system.
A set back thermostat is different.
It will follow the temperature
set on the dial during the timed
period and will automatically
reduce the set temperature by
4°C when its timed to be off.
Surface mounting:
DS1/DS1-L and
DS1-E/DS1-EL
Flush mounting:
DS-SB
Temperature Range
05-35°C
A slide switch on the side
of the thermostat allows you
to switch between On,
Permanent Off or Time
Clock. In On mode, the
thermostat will maintain the
set temperature on the dial, but
will ignore the time clock input.
Lock Facility
DS1-L / DS1-EL
Indication Type
LED: DS1/DS1-E/DS-SB
LCD: DS1-L/DS1-EL
Surface Mount with LED
Indication - DS1 Series
2 Models, suitable for water
& electric heating systems.
Set Back Facility
DS-SB
Dimensions
DS1/DS1-L/DS1-E/DS1-EL
92x92x34mm (L,H,D)
DS-SB
92x92x17mm (L,H,D)
E.U. Back Box
DS-SB
Dial Type Thermostats
Surface Mount with LCD
Indication - DS1-L Series
2 Models, suitable for water
& electric heating systems.
Power and Heating Indication
The DS1 series provides power
Power
and Heating
Indication
and heating
on indication
in
The
DS1 series
provides
power
the form
of coloured
LEDs.
and heating on indication in
the
of colouredRead-out
LEDs.
LCDform
- Temperature
Surface Mount for Easy
Installation
The DS1 and DS1-L series are
surface mounting for easy
installation. Modern styling
remains in keeping with the rest
of the Heatmiser range.
Dial Lock Facility
The DS1-L series offers a dial
lock, allowing you to reduce
tampering of the heating
system. A simple way of
reducing your energy costs.
The DS1-L is equipped with
an LCD. A turn of the dial will
display the set temperature for
5 seconds before reverting back
to the actual room
temperature
Temperature
Range
Limit
read-out.
On
the DS-SB Public thermostat
MAX
MAX
you can limit the temperature
Temperature
Range
Limit
range.
Adjustment
is only
On the DS-SB
Public thermostat
possible
by removing
a screw
you can the
limitDS-SB
the temperature
making
Public features
range.for
Adjustment
is applications.
only
ideal
commercial
possible
byisremoving
a screw
The
DS-SB
shipped ready
making
DS-SB but
Public
to
work the
in On/Off
canfeatures
be
ideal for
applications.
wired
to commercial
work in SetBack
Mode.
The DS-SB is shipped ready
to work in On/Off but can be
wired to work in SetBack Mode.
02
FEATURES
AIR ONLY MODELS
AIR & FLOOR MODELS
DS1
DS1-L
DS-SB
DS-SB Public
DS1-E
DS1-EL
Temperature Range
05-35 °C
05-35 °C
05-35 °C
05-35 °C
05-35 °C
05-35 °C
Mounting Type
Surface
Surface
Flush
Flush
Surface
Surface
Set Back Function
N
N
Y
Y
N
N
Digital Display
N
Y
N
N
N
Y
Time Clock Override Switch
N
N
Y
N
N
N
Dial Lock
N
Y
N
Y
N
Y
Built In Air Sensor
Y
Y
Y
Y
Y
Y
Remote Air Sensor
N
N
Y
Y
N
N
Floor Sensing Mode
N
N
N
N
Y
Y
Floor Probe Included
N
N
N
N
Y
Y
Built In Air & Floor
N
N
N
N
Y
Y
Y
Y
N
N
Y
Y
N
N
N
Y
N
N
Range Limit (Screw required to adjust)
Accuracy
Dimensions
+/- 1.5°C
+/- 1.5°C
+/- 1.5°C
+/- 1.5°C
+/- 1.5°C
+/- 1.5°C
92x92x34mm
92x92x34mm
92x92x17mm
92x92x17mm
92x92x34mm
92x92x34mm
3A
3A
3A
3A
13A
13A
Supply
230VAC
230VAC
230VAC
230VAC
230VAC
230VAC
Weight
150g
150g
150g
150g
150g
150g
Max Switching Current
Flush Mount
with Set Back Function
DS-SB
Public Thermostat
with Range Limit
DS–SB Public
Stylish Thermostats For Modern Living
Surface Mount
with LCD Indication
DS1-L Series
Surface Mount
with LED Indication
DS1 Series
03
Slimline Thermostats
Our most popular product line
Three ranges are available,
available, including
including our
230v
Slimline
Models230v
for standard
model, Slimline-E
systems, Electric
12v Network
Floor Heating
Models for
model
those
and
looking
our 12v
toNetwork
control their
Models
system
ideal for those
lookingFloor
to control
their
centrally.
centrally
and Electric
Models
for system
those with
Electric Floor Heating.
Headline
Information
Product
Ranges
Key
Features
Mounting Type
Flush mounting
230v Models
Model
Can be used to upgrade
existing thermostats and can
be used in conjunction with
our UH2 and UH3
UH8
wiring centres.
Modern Slimline Appearance
The slimline thermostat series
12v Network Models
Have been designed to work
as part of a network system,
12v Network Models
and can be used in conjunction
Have been designed to work
with our UH1 wiring centre and
as part of a network system,
network products.
and can be used in conjunction
*See pages 25 for system
with our UH1 wiring centre and
overview.
network products.
Electric
Floor
*See pages
25 Model
for system
Supplied
overview.with a remote floor
sensor, the Slimline-E offers
the ability to measure room
temperature, floor temperature
or both. The Slimline-E is rated
at 16A making it ideal for electric
Electric
Floor Model
floor heating.
Supplied with a remote floor
sensor, the Slimline-E offers
the ability to measure room
temperature,
floor temperature
Sensor
Housing
or both. The Slimline-E is rated
Part
Heatmiser
EN030
at 16A making Ref:
it ideal
for electric
This sensor housing is ideal for
floor heating.
use in en-suites to house the
remote sensor probe.
Holiday Function
Energy Saving Optimum Start
Reduces the set temperature
Calculates the amount of heat
in your home for the duration
up time required to ensure
Holiday Function
Energy Saving Optimum Start
of your holiday and returns
your home is warm when you
Reduces the set temperature
Calculates the amount of heat
to programmed settings to
wake and return home. This
in your home for the duration
up time required to ensure
ensure your home is warm on
is automatically optimised
of your holiday and returns
your home is warm when you
your return.
throughout the year to save you
to programmed settings to
wake and return home. This
money.
ensure your home is warm on
is automatically optimised
Temperature
Temperature
Hold
your
return. Override
throughout
the
yearFacility
to save you
Allows you to adjust the desired
Allows you to hold a set
money.
temperature in your home
without the need to fully
duration - ideal for parties.
re-program the thermostat.
After which, the thermostat
This new set temperature will
will revert back to the
Temperature Override
Temperature Hold Facility
be maintained until the next
programmed setting.
Allows you to adjust the desired
Allows you to hold a set
programmed setting.
temperature in your home
without the need to fully
duration - ideal for parties.
re-program the thermostat. Remote Sensor
AfterProbe
which, the thermostat
MISC103
This new set temperature will Part Ref: Heatmiser
will revert
back to the
probe can
be used to
be maintained until the next This remote sensor
programmed
setting.
programmed setting.
probe is supplied with a 3 meter cable which
can be extended to 20 meters if required.
Temperature Range
05-35°C
41-95°F
Lock Facility
Yes - All models
Indication Type
LCD with Blue Back Light
Optional Extras
Infrared Remote Control
Dimensions
98x85x16mm (L,H,D)
(13mm Installed)
E.U. Back Box
Slimline Thermostats
a depth of only 13mm after
installation.
Remote Control
All models within our slimline
series are compatible with our
Infrared remote control.
(Part Reference: RM1)
04
FEATURES
230V
12V
ELECTRIC FLOOR MODEL
Slimline
Slimline-N
Slimline-HW-N
Slimline-E
Temperature Range
05-35 °C
41-95 °F
05-35 °C
41-95 °F
05-35 °C
41-95 °F
05-35 °C
05-95 °F
Blue Back Lit Screen
Y
Y
Y
Y
5/2 Day Programming Mode
Y
Y
Y
Y
7 Day Programming Mode
Y
Y
Y
Y
Number of Heating Levels
4
4
4
4
Optimum Start
Y
Y
Y
Y
Number of HW Times
N
N
Y
N
Holiday Function
Y
Y
Y
N
Keylock Function
Y
Y
Y
Y
Temperature Hold Function
Y
Y
Y
Y
Temperature Override
Y
Y
Y
Y
Temperature Override Limit
Y
Y
Y
Y
Frost Protection
Y
Y
Y
Y
Networking Facility
N
Y
Y
N
°C / °F Option
Y
Y
Y
Y
Remote Air Sensor Connection
Y
Y
N
Y
Remote Air Sensor Included
N
N
N
N
Built In Air Sensor
N
Y
Y
Y
Floor Sensing Mode
N
Y
N
Y
Floor Sensor Included
N
N
N
Y
Max Switching Current
3A
3A
3A
16A
+/-1 °C
+/-1 °C
+/-1 °C
+/-1 °C
Infrared Remote Control Option
Y
Y
Y
Y
Adjustable Switching Differential
Y
Y
Y
Y
230VAC
12VDC
12VDC
230VAC
Accuracy
Supply
98x85x13mm(L,H,D)
Installed Dimensions
195g
Weight
98x85x13mm(L,H,D)
195g
195g
98x85x13mm(L,H,D)
195g
Thimble Sensor
Remote Sensor Probe
Part Ref: Heatmiser Thimble Sensor
The Heatmiser Thimble sensor is ideal for
discrete temperature monitoring and is
compatible with all Heatmiser Thermostats
with a remote sensor connection.
Part Ref: Heatmiser MISC103
This remote sensor probe can be used to measure air and floor
temperature. This probe is supplied with a 3 meter cable which
can be extended to 20 meters if required.
Stylish Thermostats For Modern Living
05
TouchScreen Thermostats
Making your life a little easier
The intuitive TouchScreen display makes searching for the user manual a thing of the past.
Headline
Information
Product
Ranges
Key
Features
Mounting Type
Flush mounting
230v Models
5/2 & 7 Day Programming
Frost Protection
Can be used to upgrade
existing thermostats and can
be used in conjunction with
our UH2 and UH8
wiring centres.
5/2 Day mode is ideal for those
who keep to one schedule
Monday - Friday and another
for the weekend. 7 Day mode
allows you to have a different
schedule for each day of the
week. Ideal for families with
changing schedules.
A function designed to protect
your home against frost.
An adjustable frost
temperature level can be
programmed, between
7°C - 17°C, ensuring your home
is always protected against the
elements whilst you are away.
12v Network Models
Adjustable Switching
Differential
Keylock Function
Temperature Range
05-35°C
41-95°F
Lock Facility
Yes - All models
Indication Type
LCD with Blue Back Light
Adjustable Switching
Differential
0.5-3°C
Dimensions
110x100x17mm (L,H,D)
E.U. Back Box
Touch Screen Thermostats
Have been designed to work
as part of a network system,
and can be used in conjunction
with our UH1 wiring centre
and network products. See
page 24 and 25 for our system
overview.
Our TouchScreen Series has
an adjustable switching
differential from 0.5°C - 3°C.
This function allows you to get
even tighter control of your
heating system.
Locking the thermostat
keypad is an easy way to save
energy. Allowing access to
only those that require it.
Air / Floor Models
Networking Facility
Two Zone Models
Are supplied with a remote
floor sensor and provide
the ability to measure room
temperature, floor temperature
or both. The Touch-E offer 16A
switching making them ideal
for electric floor heating.
Control your heating from
anywhere. Our 12v network
thermostats offer you the
ability to control your heating
centrally, with the use of our
TouchPad. Take a look at pages
24-25 for more details on our
network products.
The Touch-Duo is ideal for
bedrooms with ensuite.
Zone one uses the built in
air sensor whilst zone two
uses the remote thimble
sensor provided.
06
FEATURES
230V
230V
MODELS
Touch-Duo
Touch PRT-TS
| PRT-RPTS
DT-TS | DT-RPTS
ELECTRICFLOOR
FLOORMODEL
MODEL
ELECTRIC
12V
12V NETWORK
MODELS
PRT/HW-TS
Touch-N
DT-NTS
Touch-HWN PRT-ENTS
PRT-NTS PRT/HW-NTS
Touch-E PRT-ETS
DT-ETS
Blue Back Lit Screen
Y
Y
YY
Y
YY
Y
Y
Y
Y
Y
Y
5/2 Day Programming Mode
N
Y
YY
Y
NY
Y
Y
Y
N
Y
Y
7 Day Programming Mode
N
Y
YY
Y
NY
Y
Y
Y
N
Y
Y
Number of Heating Levels
1
4
44
4
14
4
4
4
1
4
4
Optimum Start
N
Y
YY
Y
NY
Y
Y
Y
N
Y
Y
Number of HW Times
0
N
0N
4
0N
0
Y4
0
0
N
0
Holiday Function
Number
of Zones
N
1
Y2
Y
N-
Y
Y-
Y
N
-
Y
Keylock Function
Holiday
Y
Y
YY
Y
YY
Y
Y
Y
Y
Y
Y
Temperature
Hold Function
Keylock
Function
N
Y
YY
Y
NY
Y
Y
Y
N
Y
Y
Override
Temperature Hold
Function
Y
Y
YY
Y
YY
Y
Y
Y
Y
Y
Y
Temperature Override Limit
Y
Y
YY
Y
YY
Y
Y
Y
Y
Y
Y
Frost Protection
Temperature
Override Limit
Y
Y
YY
Y
YY
Y
Y
Y
Y
Y
Y
Networking
Facility
Frost
Protection
N
Y
NY
N
YY
Y
Y
Y
N
Y
N
°C / °F OptionFacility
Networking
Y
N
YN
Y
YY
Y
Y
Y
Y
N
Y
Built
Air Sensor
°C
/ °FInOption
Y
Y
YY
Y
YY
Y
Y
Y
Y
Y
Y
Remote
AirSensor
Sensor
Built
In Air
N|Y
Y
N | YY
N
NY
N
N
Y
Y
Y
Y
Y
Remote Air Sensor Included
N|Y
N
NN
N
NY
N
N
N
N
Y
N
Floor Sensing
ModeIncluded
Remote
Air Sensor
N
N
NN
N
NN
N
N
Y
Y
N
Y
Floor Sensor
Included
Thimble
Air Sensor
Included
N
N
NY
N
NN
N
N
Y
Y
N
Y
Max Switching
Current
Floor
Sensing Mode
3A
N
3AN
3A
3AY
3A
3A
N
3A
16A
Y
16A
+/-1°C
Y
Accuracy
Floor
Sensor Included
+/-1°C N
N
+/-1°C
+/-1°C
+/-1°C
N
+/-1°C
+/-1°C
N
+/-1°C
Max Switching Current
0.5 - 3°C 3A
3A
0.5 - 3°C
0.5 - 3°C
0.5 -3A
3°C
0.5 - 3°C
0.53A
- 3°C
0.5 - 3°C
0.5 - 3°C 16A
Accuracy
Supply
230VAC+/-1°C
+/-1°C
230VAC
230VAC
12VDC
+/-1°C
12VDC
12VDC
+/-1°C
12VDC
230VAC+/-1°C 230VAC
+/-1°C
0.5 - 3°C
Adjustable Switching Differential
0.5 - 3°C
0.5 - 3°C
0.5 - 3°C
0.5 - 3°C
0.5 - 3°C
Supply
230VAC
230VAC
12VDC
12VDC
230VAC
Available In
Three Plastic
Colour Finishes
Thimble Sensor
White
Part
Ref: Heatmiser
Sensor
HousingThimble Sensor
The
Heatmiser
Thimble
sensor is ideal for
Part Ref: Heatmiser
EN030
discrete temperature monitoring and is
This sensor housing is ideal for use in
compatible with all Heatmiser Thermostats
en-suites to house the remote sensor probe.
with a remote sensor connection.
Stylish Thermostats For Modern Living
Silver
Remote Sensor Probe
Black
Part
Ref: Heatmiser
Remote
Sensor MISC103
Probe
This remote sensor probe can be used to measure air and floor
Part Ref: Heatmiser MISC103
temperature. This probe is supplied with a 3 meter cable which
can be extended to 20 meters if required.
temperature. This probe is supplied with a 3 meter cable which
can be extended to 20 meters if required.
07
Battery Thermostats & Time Clocks
Slimline design to compliment any environment
Battery Thermostat Series
Headline
Our battery thermostats are a viable upgrade route for those with a dial thermostat working on a 2 wire system.
Information The design follows our slimline thermostat series with Non-programmable and Programmable models being available.
Key
Mounting Type
Battery Thermostats:
Features
Surface mounting
Time Clocks:
Flush mounting
Battery Thermostat
Temperature Range
05-35°C
Lock Facility
Battery powered
Surface mount
Powered from 2 x AAA Batteries – suitable for
2 wire heating systems.
Our battery thermostats are surface mounted
for easy installation, making them perfect for the
Optimum Start
Key Lock Function
A feature whereby the thermostat calculates
the amount of heat up time required, is
standard on the Programmable model (PRT-B).
Our battery thermostats are equipped with a
key lock helping to prevent energy usage by
restricting access.
Yes - All models
Indication Type
LCD with Blue Back Light
FEATURES
Dimensions
Battery Thermostats:
86x99x24mm (L,H,D)
Slimline Time Clocks:
98x85x16mm (L,H,D)
TouchScreen Time Clocks:
92x92x17mm (L,H,D)
E.U. Back Box
Time Clock Only
BATTERY THERMOSTATS
DT-B
PRT-B
5/2 Day Programming Mode
N
Y
7 Day Programming Mode
N
Y
Number of Heating Levels
1
4
Optimum Start
N
Y
Holiday Function
N
Y
Keylock Function
Y
Y
Temperature Hold Function
N
Y
Temperature Override Limit
Y
Y
Frost Protection
Y
Y
°C / °F Option
Y
Y
Built In Air Sensor
Y
Y
Accuracy
+/-1°C
+/-1°C
Y
Y
Supply
2 x AAA
2 x AAA
Battery Thermostats & Time Clocks
Battery Thermostat
Part Ref: Heatmiser PRT-B
08
FEATURES
Slimline Time Clock
Part Ref: Heatmiser TM1
TIME CLOCKS
230V MODELS
TIME CLOCKS
12V NETWORK MODELS
TM1
TM4-TS
TM1-N
Blue Back Lit Screen
Keypad
TTouchScreen
Touch
Screen
Keypad
Keypad/TouchScreen
Y
Y
Y
Number of Zones
1
4
1
5/2 Day Programming Mode
Y
Y
Y
7 Day Programming Mode
Y
Y
Y
Number of Switching Times
4
4
4
+ Boost Facility
N
Y
N
N
Y
N
Copy Facility
N
Y
N
Countdown Timer Function
Y
N
Y
Holiday Function
Y
Y
Y
Keylock Function
Y
Y
Y
Manual Override
Y
Y
Y
Networking Facility
N
N
Y
Max Switching Current
3A
3A
3A
Changeover Output Option
Supply
Product
Ranges
Key
Features
230v Models
Are designed to work with
our UH8 wiring centre and
dial thermostat with set
back function, providing
Number of Zones
A single zone can be
controlled on the TM1
series and 4 zones can
be controlled on the TM4
series.
Y
N
N
230VAC
230VAC
12VDC
+ Boost Facility
A mode select button
providing an easy method
of switching between
permanent on, permanent
This programmable function allows
you to extend the program time,
in 30 minute increments - ideal for
unscheduled operation of the system.
mode) TM4 only.
12v Network Models
Have been designed to
work as part of a network
system, and can be used
in conjunction with our
UH1 wiring centre and
network products.
Number of
Switching Times
provided on all time
clock models, allowing
heating system.
Stylish Thermostats For Modern Living
Countdown Timer
From Towel Rails to Lighting
A simple yet useful function
that enables the output
for the duration of the
programmed countdown
time.
All time clock models can be used to control
anything - not just your heating system. In
fact, those using our networking system can
control each time clock independently from
the TouchPad or over the internet, so it makes
sense to use one of our time clocks wherever
you want complete control.
09
Wireless Thermostats
Wireless design for easy installation
alternative, and are the ideal choice for extensions or when you are looking to relocate your thermostat.
Headline
Information
Key
Features
Mounting Type
Relocate
Rechargeable Battery
Fail Safe
TouchScreen:
Desk & Wall mounting
Slimline:
Wall mounting
(TouchScreen models only)
Our Wireless TouchScreen
series incorporate a
rechargeable battery,
saving money on
replacement batteries.
A USB recharge cable is
provided, and an optional
plug-in charger is available.
A loss of wireless connection
could leave your home
vulnerable to frost damage.
The fail safe function
enables the heating for 20%
of the time, ensuring the
temperature in your home
does not drop to
dangerous levels.
Yes - All models
Many thermostats are sited
incorrectly, causing your boiler to
come on more than necessary.
A wireless thermostat allows you
to move your thermostat to a more
suitable position, without the need
to run additional cables. What’s
more, our TouchScreen models
have a desk stand, enabling you to
move the thermostat around the
house with you.
Indication Type
Key Lock Function
Compatible
Electric FloorReceivers
Model
Easily Change Batteries
LCD with Blue Back Light
A simple way to reduce
tampering of the system
settings, and standard across
our wireless thermostat series.
Our Wireless thermostats
are
compatible
withof
our
models
are capable
2switching
channel RF-Switch
and
up to 16A and
8 zone UH8-RF wireless
receivers.
Temperature Range
05-35°C
41-95°F
Lock Facility
Dimensions
TouchScreen Thermostats:
110x100x21mm (L,H,D)
Battery Thermostats:
86x99x24mm (L,H,D)
TouchScreen Wireless Thermostat Series
Wireless Thermostats
Rechargable Battery (via USB)
(Slimline models only)
Slimline Wireless Thermostat Series
10
FEATURES
AIR ONLY MODELS
FEATURES
ELECTRIC
FLOOR
MODELS
Slimline-RF
SLIMLINE WIRELESS SERIES
COMPATIBLE RECEIVERS
Compatible Receivers
PRT-W
DT-W
RF Switch
RC1-W Compatible
UH8-RF
Y
TOUCHSCREEN WIRELESS SERIES
PRTHW-W
DT-EW
PRT-EW
Y
N
N
Y
N
N
N
Y
Operating Type
N
N
N
RC1-WTS Compatible
N
Temperature Range
N
N
N
RC2-WTS Compatible
N
Heating Only Mode (Selectable by User)
Y
Y
Y
UH1-W Compatible
N
Heating & Hot Water Mode (Selectable by User)
05-35 °C
05-35 °C
05-35 °C
05-35 °C
Non Programmable Mode
Temperature Range
41-95 °F
41-95 °F
41-95 °F
41-95 °F
5/2 Day Programming Mode
Y
Y
N
N
5/2 Day Programming Mode
7 Day Programming Mode
Y
Y
N
N
7 Day Programming Mode
Number of Heating Levels
4
4
1
1
Number of Heating Levels
Optimum Start
Y
Y
N
N
Optimum Start
Number of HW Times
RC2-W Compatible
ELECTRIC
FLOOR
MODELS
Touch-RF
AIR ONLY MODELS
Y
N
N
N
05-35 °C
41-95 °F
Y
Y
4
Y
DT-WTS DT-UWTS
Y
N Y
PRT-WTS PRT-UWTS
N
N
N
N
N
Button
N
Y
05-35 °C - 41-95 °F
N
N
Y
Y
N
Y
05-35 °C
Y
41-95 °F
Y
N
Y
N
4
1
Y
N
4
N
N
Y
N
N
N
N
Y
05-35 °C
41-95 °F
Y
Y
4
Y
PRTHW-WTS PRTHW-UWTS
Y
NY
N
Touchscreen
Y
05-35 °C - 41-95 °F
N
Y
N
Y
05-35 °C
Y
41-95 °F
Y
Y
Y
Y
4
4
Y
Y
4
DT-EWTS PRT-EWTS
N
N
N
N
N
N
N
N
N
N
Y
Y
Y
N
N
05-35 °C
05-35 °C
41-95 °F
41-95 °F
N
Y
N
Y
1
4
N
Y
0
Holiday Function
N
Keylock Function
0
4
0
0
Y
4
0
0
Y
Y
N
Y
Y 0
Y N
0
Holiday Function
Y
Y
Y
N
Y
Number of HW Times
Keylock Function
Y Hold
Temperature
Y
Y
Y
Y
Y Y
Y
Y
Y
Y
Y
Temperature Hold
N Override Y
Temperature
Y
N
Y
Y N
Y
Y
Y
N
Y
Temperature Override
Y
Frost Protection
Y
Y
Y
Y
Y Y
Y
Y
Y
Y
Y
Frost Protection
C/F FunctionY
Y
Y
Y
Y
Y Y
Y
Y
Y
Y
Y
°C / °F Option
Built in Air Sensor
Y
Y
Y
Y
Y
Y Y
Y
Y
Y
Y
Y
Built in Air Sensor
Remote Air Y
Sensor Connection
Y
Y
Y
Y
Y Y
Y
N
Y
Y
Y
N
Y
Y
1 °C N
N
1 °C
N
N
N
N
N
N
Y
N
N
N
Y
Y
Y N
Y N
N
N
N
Y
N
Y
Y
N
868MhZ
N
N
N
+/-1°C
+/-1°C
+/-1°C
Y
Y
Y
Y
Remote Air Sensor ConnectionAccuracy N
Diff
N erential
N
Remote Air Sensor Included Adjustable Switching
Floor Sensing Mode
Wireless FailNSafe Function
N
Floor Sensor Included
RF Frequency
N
N
N
Operational Radio Range (Open Space)
+/-1°C
+/-1°C
+/-1°C
Power
Y
Y
Y
Battery Lifetime
Y
Y
Y
USB Power Lead Included
868MHz
868MHz
868MHz
Mounting Type
Up to
Up to
Up to
Dimensions
100M
100M
100M
Accuracy
Wireless Fail Safe Function
RF Frequency
Operational Radio Range
(Open Space)
N
+/-1°C
Y
Y
868MHz
Up to
100M
868MhZ
N
Up to 100M
+/-1°C
+/-1°C
2 X AAA
Y
Y
1 Year
Y
Y
N
868MHz
433MHz | 868MHz
Wall
Up to
Up to
85mm(L) x 98mm (H) x 24mm
100M
100M
N
Up to 100M
+/-1°C
Rechargeable Battery
Y
1 Year
Y
Y
Y
433MHz | 868MHz
433MHz | 868MHz
Wall/Desk
Up to
Up to
110mm(L) 100mm (H) x 20mm (D)
100M
100M
Y
Y
433MHz
Up to
100M
Power
2 x AAA
2 x AAA
2 x AAA
2 x AAA
2 x AAA
Battery Lifetime
Typically
Typically
Typically
Typically
Typically
Typically
Typically
Typically
Typically
1 Year
1 Year
1 Year
1 Year
1 Year
6-8 Months
6-8 Months
6-8 Months
6-8 Months
USB Power Lead Included
Mounting Type
Dimensions
Rechargable Battery (Mini USB Connection)
N
N
N
N
N
Y
Y
Y
Y
Wall
Wall
Wall
Wall
Wall
Wall/Desk Stand
Wall/Desk Stand
Wall/Desk Stand
Wall/Desk Stand
85mm(L) x 98mm(H) x 24mm(D)
Stylish Thermostats For Modern Living
110mm(L) x 100mm(H) x 20mm(D)
11
Wireless Receivers
H
HW-UWTS
A
H
PRT-W
Wireless Thermostat Inc HW)
A
H
PRT-W
(Programmable Wireless Thermostat)
PRTHW-UWTS
(Programmable Wireless Thermostat)
ply
Headline
Headline
Information
Information
ADDRESS
N
L
nals)
FUSE 1
ACTUATORS
W
alve
ess Thermostat)
Slimline Thermostat Wireless Receivers
FUSE 4
12V FUSE CONTROL
FUSE 3
CONTROLS
Mounting
Type
PRT-W
PRTHW-UWTS
H
A
H
Wireless
Antenna
A
PRT-W UH1-W
RF Switch
/ Boost
Slimline
& TouchScreen
Receivers:
Flush Mounting
Surface Wiring
Mounting
UH1-W
Centre:
Wall Mount
(Programmable Wireless Thermostat Inc HW)
(Programmable Wireless Thermostat) (Programmable Wireless Thermostat)
Heating
UH8-RF
ostat
N
L
ADDRESS
L
DHW
SL
ZONE1
N
FUSE 4
12V FUSE CONTROL
N
ntrol
To Boiler
Enable
N
L
N
L
FUSE 2
ZONE 8
PUMP
VALVE
N
L
L
ZONE 7
N
L
ZONE 8
108x90x24mm
(L,H,D) Receivers:
Slimline
& TouchScreen
Radiator Zone Valve
UH8-RF:
86x86x16mm
(L,H,D)
384x148x60mm
(L,H,D)
Wiring
Centre Receiver:
290x200x70mm (L,H,D)
PUMP
VALVE
N
L
L
Compatability
Compatability
UFH Manifold
(Using 230v Actuators)
Wireless Slimline
Thermostat
Wireless
Slimline
Thermostat
Part Ref: Slimline-RF
Wireless
Receivers
(Using 230v Actuators)
Part Ref: Heatmiser RC1-W
The Heatmiser RF Switch is our surface mount 2 channel RF Receiver
compatible with the Slimline RF and Touch RF Thermostats.
capable of controlling two heating zones, using our DT-W/PRT-W or
one heating and one hot water zone, using our PRTHW-W.
A single Slimline RF / Touch RF in Heating Only mode or a single
Slimline RF / Touch RF in Heating/Hot Water mode can be paired to
the RF Switch.
Part Ref: Heatmiser RC2-W
The RF Switch can be
paired to multiple UH8-RF,
providing a wireless link for
the boiler signal.
Slimline Wireless Repeater
Part Ref: WR1
The WR1 is our 230v powered wireless repeater, designed to extend the communication
8 Zone Wiring Centre
distance between the thermostat and receiver.
Part Ref: Heatmiser UH8-RF
Wireless Slimline Thermostats
DT-W, PRT-W, PRT-EW, PRTHW-W
Wireless TouchScreen Thermostats
DT-UWTS, PRT-UWTS,
PRTHW-WUTS
UFH Manifold
Part Ref: Heatmiser PRT-W
Heatmiser
RF Switch
Wireless
Receiver
for Twin Heating Zones
In addition to the two changeover contacts for the heating and hot
water circuits, the RF Switch provides a volt free switch for the boiler.
with our DT-EW or PRT-EW thermostat and is supplied with a 3 meter
Wireless
Antenna
To Boiler FUSE 2
Enable
ZONE 6
N
e Thermostat
miser PRT-W
N
L
ZONE 7
STAT 6
VALVE
AND
PUMP
ENABLE
Radiator Zone Valve
Centre
H1-W
ZONE 6
Dimensions
RF Switch / Boost
Dimensions
UH1-W
oducts
ZONE 5
N
L
Radiator Zone Valve
ermostat)
L
ZONE 4
STAT 6
VALVE
AND
PUMP
ENABLE
To Boiler
Enable
W
N
ZONE 3
N
L
LED
Radiator Zone Valve
To Boiler
Enable
ZONE 5
ZONE 2
Indication Type
LED
Indication
Type
L
L
A
BOILER
ENABLE
(VOLT FREE)
Fused Spur)
N
H
PRT-W
(Programmable Wireless Thermostat) (Programmable Wireless Thermostat)
Our wireless receivers are designed Heating
to work with our wireless thermostats and are ideally suited for water underfloor heating and
conventional
heating systems.
as
well as conventional
radiator systems.
adiators
ZONE 4
A
PRT-W
(Programmable Wireless Thermostat Inc HW)
Heatmiser Boost
Wireless TouchScreen Thermostat
Part Ref: Heatmiser PRT-UWTS
UH1-W, RC1-W, RC2-W
E.U. Back Box
The Heatmiser Boost is our surface mount 230v powered wireless
repeater for the RF and Neo systems designed to extend the
TouchScreen Thermostat Wirelesscommunication
Receivers distance between the thermostat and receiver.
Wireless Receiver for Twin Heating Zones
Part Ref: Heatmiser RC1-WTS
Wireless TouchScreen Thermostat
Wireless
TouchScreen
Thermostat
Part Ref: Heatmiser
PRT-UWTS
Part Ref: Touch-RF
Wireless Receivers
TouchScreen wireless thermostats. Two heating zones can be controlled using our
DT-WTS/PRT-WTS or alternatively, one heating and one hot water zone can be controlled from
this receiver using our PRTHW-WTS.
12
FEATURES
Mounting Type
Compatible with
RF-Switch
UH8-RF
Surface
Surface
Slimline RF / Touch RF
Slimline RF / Touch RF
Number of Channel
2
8
Fail Safe
Y
Y
Power
230V AC
230V AC
Rating
3A
3A
Optional Extendable Aerial
N
Y
868MHz
868Mhz
Operating Frequency
Range(Open Space)
100M
100M
Pump Output
N
Y
Zone, HW & Pump Output Test Mode
N
Y
Boiler Enable
Y
Y
HW Cylinder Thermostat Connection
N
Y
Per Zone UFH / Radiator Selection
N
Y
Wireless Wiring Centre
Wireless 230v 8 Zone Wiring Centre
Part Ref: Heatmiser UH8-RF
The UH8-RF is designed to be used in conjunction with our Slimline RF and Touch RF Wireless
Thermostats.
The UH8-RF provides central switching and is therefore ideally situated next to the underfloor heating manifold. Eight zones can be controlled as well as providing an output for a hot water cylinder.
On demand from any zone, a 230v output is provided to switch the relevant zone actuators, underfloor heating pump and valve. A volt free connection is supplied for the boiler making it compatible
with almost all types of boilers. The RF Switch can also be paired to multiple UH8-RF providing a
wireless link for the boiler enable signal.
Up to 6 actuators can be connected to each zone. An external aerial is available for use when the
UH8-RF is being mounted in a metal cupboard or when the wireless signal is restricted.
A software option in the thermostat allows you to configure which zones are underfloor heating
and which zones are radiators. Radiator zones will not enable the underfloor heating pump and
underfloor heating valve when there is a call for heat.
Stylish Thermostats For Modern Living
13
WiFi Smart Thermostat
SmartStat is our all-new WiFi Connected Thermostat with full colour LCD.
Now is the time to take control of your multi zone heating and hot water system from anywhere. What’s more, our Geo Location feature
ensures you never heat an empty home.
Headline
Information
Key
Features
Mounting Type
Flush mounting
Control from your
SmartPhone
Temperature Range
05-35°C
41-95°F
Indication Type
2.8” Full Colour LCD
Dimensions
95x95x45mm
(15mm installed)
E.U. Back Box
SmartStat has built in WiFi
so connects directly to your
Home Router. As SmartStat
connects to your SmartPhone
via our cloud server setup
is a dream and will take
minutes – no technical setup
here. SmartStat is compatible
with iPhone & iPad and with
Android SmartPhones &
Tablets.
Heat or Timer Option
The SmartStat can be setup
to work in either Heat or
Timer mode, so is perfect for
controlling heating zones or
timer zones such as towel
rails and hot water.
Auto Dimming
The SmartStat Display
can be programmed to
automatically dim in low light
– making SmartStat perfect
for bedrooms.
SmartStat
Frost Protection
Geo Location
Don’t worry we have your
home covered. The in built frost
protection feature will protect
your home against the elements.
Geo Location uses the mobile
phone masts, nearby WiFi and
your GPS to calculate your
position. When you setup Geo
Location on the SmartStat App,
you set a leaving and returning
trigger. When you pass these
triggers, SmartStat will adjust
the temperature in your home
automatically.
Thermostat and
Programmer in One
Gone are the days of having
a separate programmer and
thermostat. SmartStat is both
in one so you no longer have
to fiddle with the awkwardly
positioned thermostat.
Comfort Programming
Now is the time to re-think how
you heat your home.
SmartStat lets you have different
temperatures at different times
of the day, not only an energy
saving feature but one that
creates for a more comfortable
living environment too. The Self
Learning Optimum Start feature
will automatically calculate
when your heating should be
on, so it’s one less thing for you
to worry about.
Multi-Zone
Up to 32 SmartStats can be
controlled within one location
without the need for any
network hub. Global features
such as Temperature Hold, Key
Lock and Home/Away are all
available on the SmartStat App.
Multi User
Multiple users can login to the
SmartStat App and take control
of the heating & hotwater from
anywere. In addition,
Geo Location can be configured
on each persons device meaning
the heating is turned off when
the last person has left home
and back on when the first
person returns.
14
FEATURES
SMARTSTAT
Available In Two
Stunning Colours
05-35 °C
41-95 °F
Temperature Range
Blue Back Lit Screen
Y
Non-Programmable Mode
Y
5/2 Day Programming Mode
Y
7 Day Programming Mode
Y
24 Hour Programming Mode
Y
Number of Heating Levels
4
Optimum Start
Y
Number of HW Times
0
Holiday Function
Y
Temperature Hold Function
Y
Temperature Override
Y
Temperature Override Limit Frost
Y
Protection
Y
App Control
Y
°C / °F Option
Y
Remote Air Sensor Connection
Y
Built In Air Sensor
Y
Floor Sensing Mode
Y
Floor Sensor Included
N
Max Switching Current
3A
Sapphire Black
+/- 1°C
Accuracy
Adjustable Switching Differential
+/- 1-3°C
Supply
230VAC
Output
Volt Free Contact
95x95x15mm (L,H,D)
Installed Dimensions
128g
Weight
Glacier White
Thimble Sensor
Remote Sensor Probe
Part Ref: Heatmiser Thimble Sensor
The Heatmiser Thimble sensor is ideal for
discrete temperature monitoring and is
compatible with all Heatmiser Thermostats
with a remote sensor connection.
Part Ref: Heatmiser MISC103
This remote sensor probe can be used to measure air and floor
temperature. This probe is supplied with a 3 meter cable which
can be extended to 20 meters if required.
Stylish Thermostats For Modern Living
15
Modern touch
touch technology
technology
Modern
TheneoStats
neoStatshave
havebeen
beendesigned
designedto
tobe
besimple
simpleto
touse
useand
andmake
makeprogramming
programmingsimple
simplewith
withthe
thenew
newintuitive
intuitivemenu
menunavigation.
navigation.
The
TheneoStats
neoStatscan
canbe
becontrolled
controlledfrom
fromanywhere
anywherethanks
thanksto
tothe
theplug
plugand
andplay
playneoHub,
neoHub,and
andare
areavailable
availableininGlacier
GlacierWhite
Whiteand
andSapphire
SapphireBlack.
Black.
The
Headline
Headline
Information
Information
Key
Key
Features
Features
MountingType
Type
Mounting
Flushmounting
mounting
Flush
ModernSlimline
SlimlineAppearance
Appearance
Modern
TheneoStat
neoStatthermostat
thermostatseries
series
The
flushmounting,
mounting,resulting
resultinginin
isisflush
depthof
ofonly
only15mm
15mmafter
after
aadepth
installation.
installation.
EnergySaving
SavingOptimum
OptimumStart
Start
Energy
Calculatesthe
theamount
amountof
ofheat
heat
Calculates
uptime
timerequired
requiredto
toensure
ensure
up
yourhome
homeisiswarm
warmwhen
whenyou
you
your
wakeand
andreturn
returnhome.
home. This
This
wake
automaticallyoptimised
optimised
isisautomatically
throughoutthe
theyear
yearto
tosave
saveyou
you
throughout
money.
money.
TemperatureHold
HoldFacility
Facility
Temperature
Allowsyou
youto
tohold
holdaaset
set
Allows
temperaturefor
foraaspecific
specific
temperature
duration- -ideal
idealfor
forparties.
parties.
duration
Afterwhich,
which,the
thethermostat
thermostat
After
willrevert
revertback
backto
tothe
the
will
programmedsetting.
setting.
programmed
Heator
orTimer
TimerOption
Option
Heat
TheneoStat
neoStatcan
canbe
besetup
setup
The
towork
workinineither
eitherHeat
Heator
or
to
Timermode,
mode,so
soisisperfect
perfectfor
for
Timer
controllingheating
heatingzones
zonesor
or
controlling
timerzones
zonessuch
suchas
astowel
towelrails
rails
timer
andhot
hotwater.
water.The
Thequick
quicksetup
setup
and
menuenables
enablesthe
theinstaller
installeror
or
menu
homeowner
ownerto
toselect
selectbetween
between
home
thetwo
twomodes,
modes,and
andby
by
the
incorporatingthe
thetwo
twomodes
modes
incorporating
intoone
oneproduct
productmeans
meansone
one
into
lessSKU
SKUfor
forstockists.
stockists.
less
WirelessNetworking
Networking
Wireless
Althoughthe
theheating
heatingsignal
signalisis
Although
hardwired,
wired,the
thecommunication
communication
hard
dataisissent
sentwirelessly
wirelesslyvia
viaour
our
data
meshnetwork
networkto
tothe
theneoHub.
neoHub.
mesh
OurNeo
Neonetwork
networkhas
hasbeen
been
Our
designedto
tooffer
offeraareliable
reliableand
and
designed
scaleablenetwork
networksystem,
system,offering
offering
scaleable
controlof
ofup
upto
to32
32neoStats
neoStatson
on
control
onenetwork.
network.The
TheneoHub
neoHubwill
will
one
automaticallyroute
routethe
thedata
data
automatically
aroundyour
yourhome
homeensuring
ensuringrange
range
around
neveran
anissue.
issue.
isisnever
Perfectfor
forNew
NewBuild
Build &
Perfect
&Retrofit
Retrofit
As
Asthe
theneoStat
neoStatisismains
mains
powered,
powered,ititisisperfect
perfectfor
fornew
new
homes
homesand
andfor
forretrofitting
retrofittingto
to
existing
existingproperties
propertiesas
asthere
there
are
areno
norequirements
requirementsfor
forCAT5
CAT5
Data
cable
and
you
don’t
Data cable and you don’t
need
needto
toworry
worryabout
aboutreplacing
replacing
batteries
either!
batteries either!
EasyNavigation
Navigation
Easy
TheneoStat
neoStatseries
seriesoffers
offersan
an
The
easyto
tonavigate
navigateprogramming
programming
easy
system,providing
providingall
allof
ofthe
the
system,
optionsacross
acrossthe
thebottom
bottomof
of
options
theblue
blueback
backlitlitdisplay.
display.
the
SoftTouch
TouchOperation
Operation
Soft
Moderntouch
touchsensitive
sensitive
Modern
keysprovide
provideaaclean
cleansmooth
smooth
keys
interface,adding
addingfurther
furtherto
tothe
the
interface,
premiumfeel
feelof
ofthe
theneoStat
neoStat
premium
series.
series.
Remote Sensing
Neo can be used with remote
air and floor sensors to cater
for applications where remote
temperature monitoring is
required.
TemperatureRange
Range
Temperature
05-35°C
05-35°C
41-95°F
41-95°F
LockFacility
Facility
Lock
Yes- -All
Allmodels
models
Yes
IndicationType
Type
Indication
LCDwith
withBlue
BlueBack
BackLight
Light
LCD
Dimensions
Dimensions
85x85x40mm(L,H,D)
(L,H,D)
85x85x40mm
(15mmInstalled)
Installed)
(15mm
E.U.Back
BackBox
Box
E.U.
Wireless
Thermostats
neoStat
neoStat
16
16
FEATURES
STANDARD MODELS
Temperature Range
ELECTRIC FLOOR
MODEL
neoStat
neoStat-hw
neoStat-e
05-35 °C
41-95 °F
N/A
05-35 °C
41-95 °F
Blue Back Lit Screen
Y
Y
Y
Non-Programmable Mode
Y
N
Y
5/2 Day Programming Mode
Y
Y
Y
7 Day Programming Mode
Y
Y
Y
24 Hour Programming Mode
Y
Y
Y
Number of Heating Levels
4
N/A
4
Optimum Start
Y
N
Y
Number of HW Times
0
4
0
Holiday Function
Y
Y
Y
Temperature Hold Function
Y
N
Y
Temperature Override
Y
N
Y
Temperature Override Limit Frost
Y
N
Y
Protection
Y
N
Y
Networking Facility
Y
Y
Y
°C / °F Option
Y
N
Y
Remote Air Sensor Connection
Y
N
Y
Built In Air Sensor
Y
N
Y
Floor Sensing Mode
Y
N
Y
Floor Sensor Included
N
N
Y
Max Switching Current
Accuracy
3A
3A
16A
+/- 1°C
N/A
+/- 1°C
Adjustable Switching Differential
+/- 1-3°C
N/A
+/- 1-3°C
Supply
230VAC
230VAC
230VAC
Output
Volt Free Contact
Changeover
85x85x15mm (L,H,D)
Installed Dimensions
128g
Weight
128g
Available In Three
Stunning Colours
Sapphire Black
Glacier White
230VAC
85x85x15mm (L,H,D)
128g
Platinum Silver
Thimble Sensor
Remote Sensor Probe
Part Ref: Heatmiser Thimble Sensor
The Heatmiser Thimble sensor is ideal for
discrete temperature monitoring and is
compatible with all Heatmiser Thermostats
with a remote sensor connection.
Part Ref: Heatmiser MISC103
This remote sensor probe can be used to measure air and floor
temperature. This probe is supplied with a 3 meter cable which
can be extended to 20 meters if required.
Stylish Thermostats For Modern Living
17
Multi-Zone Control
Modern touch technology
The
The neoStat
neoStat has
has been
been designed
designed to
to replace
replace aa standard
standard mains
mains powered
powered thermostat
thermostat and
and provides
provides the
the ability
ability to
to create
create aa network
network system,
system,
with
with local
local and
and remote
remote access.
access. With
With neo
neo you
you can
can control
control your
your heating
heating from
from anywhere
anywhere using
using your
your smartphone
smartphone or
or tablet.
tablet.
Headline
Information
Mounting
Mounting Type
Type
Flush
Flush mounting
mounting
Connectivity
Connectivity Standard
Standard
Wireless
Wireless Mesh
Mesh Network
Network
Technology
Technology
Lock
Lock Facility
Facility
Yes
Yes -- All
All models
models
SmartPhone
SmartPhone App
App
iPhone
iPhone // iPad
iPad
Android
Android Tablet
Tablet &
& Phone
Phone
Kindle
Kindle Devices
Devices
Windows
Windows Phone
Phone
Supported
Supported
Dimensions
Dimensions
85x85x40mm
85x85x40mm (L,H,D)
(L,H,D)
(15mm
(15mm Installed)
Installed)
Key
Features
Features
Local
Local Control
Control (In
(In case
case of
of loss
loss
of
of Broadband
Broadband Connection)
Connection)
Should
Should the
the internet
internet connection
connection
fail,
fail, the
the heating
heating system
system can
can still
still
be
be operated
operated within
within the
the home
home by
by
using
using the
the thermostat
thermostat keypad.
keypad.
As
As soon
soon as
as the
the internet
internet
connection
connection is
is restored,
restored, your
your
neoHub
neoHub will
will automatically
automatically logon
logon
to
to the
the Cloud
Cloud Server
Server re-enabling
re-enabling
app
app control.
control.
Multi-Zone
Multi-Zone
The
The Heatmiser
Heatmiser Neo
Neo Network
Network
system
system has
has been
been built
built from
from
the
the ground
ground up
up with
with multi-zone
multi-zone
homes
homes in
in mind.
mind. The
The neoHub
neoHub
coordinates
coordinates the
the data
data between
between
each
each neoStat
neoStat thermostat
thermostat on
on the
the
network.
network.
API
API
API -- Third
Third Party
Party Integration
Integration
Our
Our published
published API
API (JSON)
(JSON)
makes
makes it
it easy
easy for
for third
third party
party
integration
integration companies
companies to
to
integrate
integrate our
our Neo
Neo Network
Network
System
System with
with leading
leading home
home
automation
automation brands
brands products
products
from
from companies
companies such
such as
as
Control4
Control4 and
and Crestron.
Crestron.
Multi-Locations
Multi-Locations
During
During the
the installation
installation of
of
the
the app,
app, you
you are
are prompted
prompted
to
to create
create an
an account
account on
on the
the
Heatmiser
Heatmiser Cloud
Cloud Server
Server after
after
which
which multiple
multiple locations
locations can
can be
be
created.
created. Logging
Logging into
into to
to your
your
account
account from
from another
another device
device will
present
all ofallyour
Locations
for
will present
of your
Locations
quick
andand
easyeasy
access.
for quick
access.
Plug
Plug and
and Play
Play
The
neoHub connects
connects directly
directly to
to aaspare
spareport
porton
onyour
yourrouter,
router,obtaining
obtainingananIPIP
The neoHub
Address
and joining
joining itself
itself to
to your
your home
homenetwork.
network. ItIthas
hasbeen
beendesigned
designedtotobe
be
Address and
simple
simple to
to install
install and
and setup,
setup, and
and is
is compatible
compatible with
with broadband
broadband connections
connections
with
with Dynamic
Dynamic IP
IP Addresses.
Addresses. The
The neoHub
neoHub connects
connects to
to our
our Cloud
Cloud Server
Server
eliminating
eliminating any
any complex
complex setup
setup requirements
requirements including
including port
port forwarding.
forwarding.
E.U.
E.U. Back
Back Box
Box
Multi-Zone
Control
Multi-Zone
Control
18
18
Multi User Control
A new feature of the neoApp is the ability to have multiple users, providing an easy way of giving friends and family access to your
heating system.
The Share and Geo Location features mean that you never need to heat an empty home – or return to a cold home any longer.
Share
Modes
Geo Location
& Share
Guest Share
A Guest Share has limited access
to the Neo System providing the
ability to Hold a Temperature,
Lock a Thermostat, Place the
Heating into Standby mode and
make temporary temperature
changes. They cannot reprogram
heating levels, remove zones or
setup Geo Location.
Energy Saving when you Leave
Geo Location works on a User Level, so each user can setup their own preferred
Leave and Return Trigger Distances, Temperatures and Applicable Zones.
When the last person has left home, the Leave temperature will be sent to the zones
configured. Rest assured Neo won’t turn the heating off if somebody is still at home
– it only works when the last person has left.
In addition, Guest user access will
be revoked on the date set in the
neoApp - so is perfect for holiday
rental applications.
A Warm Welcome Home
When the first person heads home, the Return temperatures will be sent to the
configured zones ensuring that your home is warm for your return.
Adjustment Notifications Whenever Neo makes an adjustment to your heating
system a notification will be presented in your phones notification centre so you’re
always kept informed of the status of your Neo System.
Admin Share
Admin users have full access to
the system including the Geo
Location feature.
Stylish Thermostats For Modern Living
19
Base Level
Heating & Radiator System
Our base level water underfloor heating system uses our UH8, 8 Zone wiring centre. With the flush mount set back thermostats and
4 zone touchscreen time clock, this creates a simple, yet cost effective solution.
Headline
Information
Key
Features
Set Back Function
Connections for
8 x Zone outputs
(suitable for 230v actuators)
230v Output for UFH Pump &
Valve Control
Volt Free Boiler Enable
Component Dimensions
Time Clock
110x100x17mm (L,H,D)
Set Back Thermostat
86 x 86 x 19mm (L,H,D)
Wiring Centre
384 x 148 x 60mm (L,H,D)
Our base level heating system offers simple but
effective control of up to eight zones*.
The UH8 wiring centre is the hub of this system
and is designed to work with our four channel
230v Time Clock (TM4) and 230v Set Back
Thermostat (DS-SB). On board the UH8 are two
heating time channels. Each zone allows you to
specify which time channel it should follow.
Two additional time channel connections are
provided for hot water control or other auxiliary
devices.
* Additional zones can be controlled with the use
of a second UH8.
The set back function is a simple way of reducing
temperature when the heating is timed to be
according to the time clock controlling the system.
temperature set on the dial during the timed period
and will automatically reduce the set temperature
DIN Rail Mounting
The UH8 wiring centre can be DIN Rail Mounted
for simple, easy installation.
Providing
Wiring centre, controlling up
to 8 zones
4 Zone Master Time Clock
230v Set Back Thermostat in
each room
Neon Indication
Radiator Zone Control
Neon indicators are provided on the UH8
allowing you to see the power, valve, boiler
and zone status without the need to remove
the cover.
A simple slide switch makes zone eight suitable
for controlling a radiator zone. When used for
controlling radiators, zone 8 does not enable the
Simple Connectivity
230v Models
Are designed to work with our UH8 wiring centre
and dial thermostat with set back function,
Product List
8 Zone Wiring Centre
Part Ref: Heatmiser UH8
(See page 31)
4 Zone Time Clock
Part Ref: Heatmiser TM4
(See page 09)
Set Back Thermostat
Part Ref: Heatmiser DS-SB
(See page 03)
The UH8 allows the connection of up to eight
230v room thermostats. On demand from any
zone, a 230v output is provided to switch the
pump and valve. A volt free connection is
supplied for the boiler, making it compatible
with almost all types of boilers.
Base Level Water Underfloor Heating & Radiator System
20
neoStat (Timer)
neoStat
230VAC
CYLINDER
NOT
NOT
USED USED
L
N
A1
A2
neoStat
(Connected to Zone 2)
(Connected to Zone 1)
HOT WATER
DS-SB Thermostat
DS-SB Thermostat
VALVE
(Connected to Channel 2)
(Connected to Channel 1)
TM4THERMOSTAT
Time Clock
(4 Independant
NC Channels)
UH8
MOTOR
C
NO
UFH
POWER SUPPLY
3A 230V
L
N
UFH
UFH
L
HEATING
L
A1
N
N
SL
DS-SB STAT
DS-SB STAT
DS-SB STAT
L
L
L
N SL
R T+ R T-
L N
2
3 4
1
TIME CLOCK
SL
L N 1
3 4SL
TIME CLOCK
1
R T+ R T-
L N
L 1N 2
L N
N SL
L N
ZONE1
2
1
ZONE1
N SL
ZONE 2
1
2
ZONE 2
L
R T+ R T-
ZONE 3
2
1
ZONE 3
1
ZONE 4
L N
SL
L N 1
ZONE 4
2
L
L N
SL
2
DS-SB STAT
R T+ R T-
SL
L N 1
SL
2
N SL
L N
SL
L N 1
SL
2
SL
DS-SB STAT
L N
SL
L N 1
SL
2
A2
L
N
CH1 CH2 CH3 CH4
A1
N
A2
L
N
TM4-TS TIMER
L
UFH
BOILER
ENABLE
ZONE 5
2
1
ZONE 5
SL
L N 1
SL
2
L N
ZONE 6
2
1
ZONE 6
L N
SL
L N1
SL
2
SL
2
1
ZONE 7
2
1
ZONE 7
FOUR CORE AND
EARTH 1.5 CABLE
NO
E
L
N
E
N
1
UH3
ZONE 1
L
2
E
HEAT
ENABLE
LS
E
LR
LS AND LR IS
VOLT FREE
1
ZONE 2
2
MAINS
UFH
SUPPLY
PUMP
L
L
E
L
SL
MAINS
SUPPLY
R1
R2
N
GR OR
BOILER
L
N
N
L
N
ZONE 3
1
2
L
L
L
L
E
N
N
L
N
N
ZONE 2
L
L
N
L
UFH PUMP
2
L
SL
L
N
N
ZONEL4
ZONE 3
L
L
N
L N
N
SL
L
L N
L
N
N
ZONE 5
N
L
E
N
1
ZONE
ZONE54
L
L
ZONE 6
N
L
SL
ZONE 6
N
ZONE 7
L
E
N
ZONE 7
ZONE 5
L
N
1
LN
L
SL
L
L
N
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ACTUATOR
230V
ACTUATOR
230V
ACTUATOR
230V
1
N
2
L
SL
N
UFH
SL
ZONE 8
E
N
1
A1
2
SL
RAD
ZONE 8
ZONE 7
N
L
L
N
N
L
L
N
N
N
neoStat
(Connected to Zone 8)
DS-SB Thermostat
(Connected
to Channel 1)Zone Valve
Radiator
Boiler
Radiator Zone Valve To
Enable
N
LN
ACTUATOR
230V
E
ZONEZONE
8 6
N
ZONE 8
L
ZONE 7
2
L
N
LN
ZONE 6
2
A2
L
L
ZONE 5
2
1
ZONEZONE
3 3ZONE 4
ZONE 2
ZONE 2
L
E
N
YES
YES
ZONE 4
1
N
N
LN
UFH VALVE
Boiler
N
ZONE 1
N
L
N
N
(Via Heating/Hot
ENABLE Water System Fused Spur)
Boiler
E
ZONE 1
ZONE 1
230V AC Supply
(Via Heating/Hot Water System Fused Spur)
230V
AC Supply
BOILER
(Heating Enable Terminals)
L
SL
UFH PUMP
UFH VALVE
BOILER
UFH PUMP
N
E
NO
ZONE 8 TYPE
L
2
ZONE 8
ZONE 8
UH3
FUSE
Heating or Manifold Valve
Heating or Manifold
ValveMAINS
TIME CLOCK
5A FUSE
R T+ R T-
2
FUSE
MAINS
SUPPLY
N SL
SL
RADIATOR
VALVE
Zone 8 Isolation Switch
If set to YES, Zone 8 enables the Boiler Pump and Valve.
If set to NO
Zone 8 is isolated.
Zone 8 Isolation
Switch
VALVE WITH
ENDSWITCH
PLEASE ADD LINK TO GR AND OR IF
VALVE NOT FITTED
If set to YES, Zone 8 enables the Boiler Pump and Valve.
If set to NO Zone 8 is isolated.
(Heating Enable Terminals)
PL
SL
PL
SL
PL PERMANENT LIVE
UFM UNDER FLOOR SL
MANIFOLD
SWITCH LIVE
PL PERMANENT LIVE
LIVE SL SWITCH LIVE
TIMER LIVE
SWITCH LIVE
This equipment should be installed by an appropiately qualified/registered electrician.
Fully read the instructions for proper wiring before applying power.
The warranty does not cover damage from improper
wiring or installation.
UFH Manifold
(Using 230v Actuators)
UFH Manifold
NEUTRAL
(Using 230v Actuators)
EARTH
Standard Products
Standard Products
END SWITCH AND
BOILER ENABLE
8 Zone Wiring Centre
Part Ref: Heatmiser UH3
8 Zone Wiring Centre
8 Zone
WiringUH3
Centre
Part Ref:
Heatmiser
Part Ref: Heatmiser UH8
neoStat (Heat Mode)
Part Ref: neoStat
Stylish Thermostats For Modern Living
neoStat (Timer Mode)
Part Ref: neoStat
4 Zone Time Clock
Part Ref: Heatmiser TM4-TS
neoHub
Part Ref: neoHub
Back Thermostat
Set BackSet
Thermostat
Ref: Heatmiser
Part Ref: Part
Heatmiser
DS-SB DS-SB
21
To Boiler
Enable
Wireless
Heating & Radiator System
Designed to be easy to install and operate
Our wireless system is compatible with our wireless thermostats. Communication between the thermostat and wiring centre is achieved
by reliable RF (radio frequency) communication, using the 868Mhz frequency band. This means the installer only needs to wire the boiler,
pump and actuator connections, which are normally all local to the wiring centre.
Headline
Information
Key
Features
Features
Providing
Simple
Process
SimplePairing
Pairing
Process
Up
within
thethe
Up to
to 99
99UH8-RF’s
UH8-RF'scan
canbebeused
used
within
same
ofof
upup
to to
a a
same building,
building,allowing
allowingcontrol
control
possible
has
anan
possible792
792zones.
zones.Each
EachUH8-RF
UH8-RF
has
address
onon
the
PCB.
addresssetting
settingclearly
clearlymarked
marked
the
PCB.
This
relevant
zone
This address,
address,along
alongwith
withthe
the
relevant
zone
number
in the
thermostat
numberisiscongured
configured
in the
thermostat
and
setup
and
and that’s
that’sitit––aasimple
simpletotoinstall,
install,
setup
and
operate
operatesystem.
system.
Connectivity
Connectivity
Hot Water Control
The UH8-RF also takes care of the hot water.
Hot Water Control
A volt free changeover output is provided
The UH8-RF also takes care of the hot water.
for the cylinder stat/hot water valve.
A volt free changeover output is provided
The Slimline-RF & Touch-RF provide time and
for the cylinder stat/hot water valve.
temperature control of the heating and
The Slimline-RF & Touch-RF offer time and
time control of the hot water.
temperature control of the heating and
time control
of the
hot water.
Pump
& Boiler
Delay
DIN Rail Mounting
A software option in the thermostat allows
The UH8-RF wiring centre can be DIN Rail
you to configure which zones are underfloor
Mounted for simple, easy installation.
heating and which zones are radiators.
Radiator zones will not enable the underfloor
heating pump and underfloor heating valve
where there is a call for heat.
The UH8-RF offers an optional pump
and boiler delay feature. This 2 minute
delay is designed to prevent boilers from
going to lockout by giving the zone actuators
External Aerial
time to open.
Our external aerial is designed to work with
our UH8-RF wiring centre. Should the
Radiator or Underfloor
UH8-RF be installed in a metal cupboard
A software option in the thermostat allows
or where the RF signal is weak, an external
you to configure which zones are underfloor
aerial can be used. This 3 meter long aerial
heating and which zones are radiators.
is equipped with a magnetic base for simple
Radiator zones will not enable the underfloor
installation. It is also perfect for extending
heating pump and underfloor heating valve
the RF coverage within your property.
where there is a call for heat.
The UH8-RF wiring centre can be DIN Rail Mounted
External
for
simple, Aerial
easy installation.
Part Ref: EA1
Wiring centre,
controlling up to eight zones
Wireless thermostat in each room
Product List
8 Zone Wiring Centre
(expandable up to 792 Zones)
Part Ref: UH8-RF
(See page 30)
Compatible wireless thermostats
Examples:
Wireless Slimline Thermostat
Part Ref: Slimline-RF
Wireless TouchScreen Thermostat
Part Ref: Touch-RF
(See page 10-11 for
Optionalrange)
Products
complete
External Aerial
Part Ref: EA1
Optional Products
External
Aerial Repeater
Slimline Wireless
Part Ref: EA1
Boost
Slimline Wireless Repeater
Part Ref: RF Link
The UH8-RF works with up to eight compatible
wireless
thermostats.
On demand On
from
any
compatible
wireless thermostats.
demand
zone,
a 230v
output
is provided
to switch to
the
from any
zone,
a 230v
output is provided
relevant
zone
actuator,
heating
switch the
relevant
zoneunderfloor
actuator, underfloor
pump
and
valve.
A volt
free
connection
is
heating
pump
and
valve.
A volt
free
supplied
foristhe
boiler, making
it compatible
connection
supplied
for the boiler,
making
with
almost allwith
types
of boilers.
it compatible
almost
all types of boilers.
DIN Rail Mounting
External Aerial
Part Ref: EA1
Heatmiser Boost
The Heatmiser Boost is our surface mount
repeater for the RF System, designed to
extend the communication distance between
the thermostat and receiver.
Wireless Water Underfloor Heating & Radiator System
22
neoStat (Timer)
neoStat
CYLINDER
THERMOSTAT
A2
NC
PRTHW-UWTS
PRT-W
C
(Programmable Wireless Thermostat Inc HW)
(Programmable Wireless Thermostat)
(Programmable Wireless Thermostat)
PRTHW-UWTS
(Programmable Wireless Thermostat)
BOILER
ENABLE
L
Boiler
L N
L N
1
PL
SL
2
SL
FUSE 1
ACTUATORS
1 2
3 4
TIME CLOCK
L
A1
N
A2
ZONE1
L N
L N
SL
1
SL
1
2
ZONE 2
L N
2
ZONE 3
L N
SL
1
2
ZONE 4
L N
SL
1
2
A2
ZONE 5
L N
SL
1
DHW Zone Valve
L N
SL
FUSE 4
12V FUSE CONTROL
1 2
2
ZONE 6
ZONE 7
FUSE 3
CONTROLS
SL
1
FUSE
UH3
(TENS)
1
FUSE 5A
800MA
MA IN S IN
MAINS
SUPPLY
C
B O IL E R
UFH PUMP
BOILER
H/W
N
L
L
NO NC
L
L
N
N L
L
ZONE 1
N
L
SL
N L
N
DHW
ZONE1
LZONE
N N1
ZONE 2
L
N
N
N
L
ZONE 4
N
N
L
N
L
N
L
NO
ZONE
LZONE
N8 N8
ZONE 6
L
N
ZONE 5
N
L
7 7L
ZONE
6 N ZONE
ZONE
LZONE
L 6 N
STAT 6
VALVE
AND
PUMP
ENABLE
L
A2
A1
1 2 3 4 5 6 7 8 9 10 1112
FUSE 2
N
N
ZONE 7
PUMP
VALVE
N
L
L
NO
L
L
L
N
N
ZONE 8
L
E
N
E
L
N
VALVE
PUMP
neoStat
(Connected to Zone 8)
230V AC Supply
BOILER
ENABLE
L
ZONE
5 5
ZONE
ZONE
L 4L 4 N ZONE
N
ZONE
ZONE
N
N33
ZONE 3
N
L L N
N
L
MAINS
SUPPLY
3 AMP
ZONEL22 L
ZONE
N
L
BOILER
PAIRING
YES
(UNITS)
BOILER RF TEST
CREEPAGE ENABLE
PUMP DELAY ENABLE
NO NC
Wireless
Antenna
ZONE 8
10
Heating or Manifold Valve
C
2
BOILER RF TEST
CREEPAGE ENABLE
UH1-W
PUMP
DELAYNOENABLE
To Boiler
Enable
N
PRT-W
(Programmable Wireless Thermostat) (Programmable Wireless Thermostat)
ADDRESS
(Heating Enable Terminals)
E
A
N
L
L
H
PRT-W
(Programmable Wireless Thermostat Inc HW)
UH8-RF
A1
N
BOILER
ENABLE
(VOLT FREE)
(Via Heating/Hot Water System Fused Spur)
DHW Thermostat
A
Heating
230V AC Supply
PERMANENT LIVE
SWITCH LIVE
H
NO
Radiators
POWER SUPPLY
3A 230V
PRT-W
MOTOR
FUSE 2A
A1
A
1
2
3
4
5
6
7
8
PRT-W
N
H
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
L
neoStat
(Connected to Zone 2)
(Connected to Zone 1)
A
H/W
P UMP
B OIL ER
NOT
NOT
USED USED
HOT WATER
H
VALVE
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
ZONE 8
H/W
PUMP
BOILER
A
1 2 3 4 5
230VAC
H
HW STAT
LN
LN
LN
LN
LN
LN
LN
Radiator Zone Valve
(Via Heating/Hot Water System Fused Spur)
Radiator Zone Valve
ZONE 1
H
A
To Boiler
Enable
PRTHW-W
Boiler
(Programmable Wireless Thermostat)
(Heating Enable Terminals)
PL
SL
To Boiler
Enable
ACTUATOR
230V
ACTUATOR
230V
Z O NE 4
ACTUATOR
230V
ZONE 5
ACTUATOR
230V
ACTUATOR
230V
RADIATOR
VALVE
VALVE WITH
ENDSWITCH
Radiator Zone Valve
To Boiler
Enable
Radiator Zone Valve
(Using 230v Actuators)
UFM UNDER FLOOR MANIFOLD
Standard Products
Products
Standard
NEUTRAL
EARTH
UFH
VALVE
To Boiler
Enable
UFH Manifold
LIVE
Zone 8 Isolation Switch
If set to YES, Zone 8 enables the Boiler Pump and Valve.
If set to NO Zone 8 is isolated.
(Optional)
PERMANENT LIVE
SWITCH LIVE
UFH PUMP
ZONE 7
Z O NE 6
ACTUATOR
230V
HOT WATER
VALVE
Hot Water Control
PL
SL
ACTUATOR
230V
ZONEValve
3
Zone
ZONE Radiator
2
UFH Manifold
(Using 230v Actuators)
This equipment should be installed by an appropriately qualified/ registered electrician.
Fully read the instructions for proper wiring before applying power.
The warranty does not cover damage from improper wiring or installation.
END SWITCH AND
BOILER ENABLE
8 Zone
Wiring
Centre
Wireless
88Zone
Wiring
Centre
Zone
Wiring
Centre
UH8-RF
Part Ref:
Heatmiser
UH1-W
Part
Ref: Heatmiser
UH3
neoStat (Timer Mode)
neoStat (HeatWireless
Mode) Slimline Thermostat
Part
Ref:Ref:
Heatmiser
PRT-W Part Ref: neoStat
Part
Slimline-RF
Part Ref: neoStat
Stylish Thermostats For Modern Living
Wireless TouchScreen
Thermostat
neoHub
Part Ref:
PRT-UWTS
PartHeatmiser
Ref: Touch-RF
Part
Ref: neoHub
23
To Boiler
Enable
Low Voltage
Network Control Solution
Total control of your home heating system
Use the Heatmiser Touchpad for instant access to your heating system.
Headline
Information
Key
Features
Providing
Complete Network Control
Wiring Centre, controlling
up to 8 zones
12v Programmable
Thermostats in each room
Optional Central Control
Product List
8 Zone Wiring Centre
(expandable up to 32 Zones)
Part Ref: Heatmiser UH1
(See page 30)
Slimline Thermostat
Part Ref: Heatmiser Slimline-N
(See page 04-05 for complete
slimline range)
TouchScreen Thermostat
Part Ref: Heatmiser Touch-N
(See page 06-07 for complete
TouchScreen range)
Cable Type
Belden 9538 or Cat5(e)-ftp
Optional Products
32 zones. What’s more, it provides the ability to
control the entire heating system centrally, with the
TouchPad. Designed to be used in conjunction
with our Slimline or TouchScreen 12v Network
Thermostats, our deluxe heating system really is a
complete package for those wanting superior control
of their heating system.
Simple Connectivity
The UH1 allows the connection of up to eight
12v Network Thermostats. On demand from
any zone, a 230v output is provided to switch
pump and valve. A volt free connection is
supplied for the boiler, making it compatible
with almost all types of boilers.
Hot Water Control
Radiator Zone Control
The UH1 also takes care of the hot water. A cylinder
thermostat connection and a 230v hot water valve
output are provided. Controlling the hot water from
A simple slide switch makes zone 8 suitable
for controlling a radiator zone. When used for
controlling radiators, zone 8 does not enable
the wiring, but also because it enables you to control
your hot water centrally from the TouchPad and
remotely from the NetMonitor.
Optional Products
Central Control
Central Control
Part Ref: Heatmiser TouchPad
(See page 28-29 for details)
Low Voltage Network Control Solution
24
Network Link
Central TouchPad
Slimline-HWN
(Optional Central Control)
(To Other UH1 Units)
Touch-N
(Hot Water Control Thermostat)
(TouchScreen Thermostat)
Fri 10:23h
Y
B
H
+
BOILER
ENABLE
(VOLT FREE)
230V AC Supply
(Via Heating/Hot Water System Fused Spur)
L
-
B
+ Y
Y
-
B
A
Y
+
+
B
-
A1
+
Y
B1
A2
B
B2
-
-
A1
+
Y
B1
B2
A2
B
-
Y
A1
A2
B
+
Y
A1
A2
B
-
A1
A2
+
Y
B
TOUCHPAD SLIMLINE-HWN
ZONE 1
A2
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
B
ZONE 8
H
(Heating Enable Terminals)
Y
A1
NETWORK
N
Boiler
PERMANENT LIVE
SWITCH LIVE
-
FUSE 1
ACTUATORS
FUSE 4
12V FUSE CONTROL
A
Slimline-N
(Programmable Thermostat)
PL
SL
Radiator Zone Valve
FUSE 3
CONTROLS
To Boiler
Enable
UH1
DHW Zone Valve
To Boiler
Enable
FUSE 2
STAT 6
VALVE
AND
PUMP
Y ENABLE
N
DHW Thermostat
L
N
ZONE1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
ZONE 8
PUMP
DHW
L
SL
Zone 8 Isolation Switch
If set to YES, Zone 8 enables the Boiler Pump and Valve.
If set to NO Zone 8 is isolated.
N
N
L
N
L
N
L
N
L
N
L
N
L
L
VALVE
Hot Water Control
(Optional)
UFH Manifold
(Using 230v Actuators)
Standard Products
8 Zone Wiring Centre
Part Ref: Heatmiser UH1
Stylish Thermostats For Modern Living
Slimline Thermostat
Part Ref: Heatmiser Slimline-N
TouchScreen Thermostat
Part Ref: Heatmiser Touch-N
25
Mains Voltage Network System
Network control of your mains wired heating system from your
Smartphone and Tablet
Headline
Information
Key
Features
Connections for
Neo Network
8 x Zone outputs
(suitable for 230v actuators)
230v Output for UHF Pump
and Valve control
Volt free Boiler Enable
The Neo Network System is designed to
provide reliable communication of the
thermostat data whilst at the same time
providing an extended communication range.
Each neoStat thermostat acts as a repeater
on the network, helping to eliminate range
issues which are common on standard RF
systems.
Component Dimensions
UH8 Wiring Center
384 x 148 x 60mm (L,H,D)
Providing
Wiring centre, controlling
up to 8 zones
8 Neo Mains Network
Thermostats
Easy Upgrade
Customers with existing 230v thermostats
can upgrade to the Neo Network System and
take control of their system from anywhere.
The neoHub gateway connects the neoStats
to the internet for access via a Smartphone or
Tablet both in the home and remotely from
anywhere in the world.
Neon Indication
Neon indicators are provided on the UH8 allowing
you to see the power, valve, boiler and zone status
without the need to remove the cover.
NeoStat Thermostat Flexibility
The neoStat can be set to operate in heating
or timer mode, allowing the installer to select
on installation if the thermostat will be used
to control a heating zone or a timed appliance,
such as the hot water or perhaps a towel rail.
230v Models
Are designed to work with our UH8 wiring centre
and dial thermostat with set back function,
DIN Rail Mounting
The UH8 wiring centre can be DIN Rail Mounted
for simple, easy installation.
Product List
8 Zone wiring centre
Part ref: Heatmiser UH8
(See page 31)
7 x neoStat in Heating mode
1 x neoStat in Timer mode
(See page 16-17)
NeoHub
Optional Products
neoX (Range
Extender)
Heatmiser
Boost
has been
designed
the range
The neoX to
hasextend
been designed
of
Neo
System,
ensuring
to your
extend
the
range of
your
the
can reachthe
every
Neonetwork
system, ensuring
part
of your
network
canhome.
reach every part
of your home.
Mains Voltage Network System
Simple Connectivity
The UH8 allows the connection of up to eight
230v thermostats. On demand from any
zone, a 230v output is provided to switch the
pump and valve. A volt free connection is
supplied for the boiler, making it compatible
with almost all types of boilers.
Radiator Zone Control
A simple slide switch make’s zone eight suitable
for controlling a radiator zone. When used for
controlling radiators, zone 8 does not enable
26
neoStat (Timer)
230VAC
UFM UNDER FLOOR MANIFOLD
NOT
NOT
USED USED
LIVE
L
N
CYLINDER
THERMOSTAT
A1
A2
UH8
HOT WATER
VALVE
neoStat
neoStat
(Connected to Zone 1)
(Connected to Zone 2)
NC
MOTOR
C
TIMER LIVE
SWITCH LIVE
UFH
UFH
NEO STAT
NEO STAT
NO
UFH
UFH
HEATING
NEO
STAT
A1
NEO STAT
NEUTRAL
EARTH
POWER SUPPLY
3A 230V
BOILER
ENABLE
END SWITCH AND
BOILER ENABLE
L
N
L
N A1 A2 - R T 1 R T 2
1
2
L N
THREE CORE AND
EARTH 1.5 CABLE
L N
3 4
TIME CLOCK
MAINS
SUPPLY
L N
SL
1
N A1 A2 - R T 1 R T 2
L
2
ZONE1
L
L N
SL
1
ZONE 2
N A1 A2 - R T 1 R T 2
L N
SL
1
2
L
2
ZONE 3
2
ZONE 4
L N
SL
1
A2
N A1 A2 - R T 1 R T 2
L
L N
SL
1
NEO STAT
A1
N
A2
2
SL
1
ZONE 5
2
L N
ZONE 6
L N
SL
1
2
N
TIME CLOCK
E
N 1
L
E
L
E
ZONE 1
N
1
SL
2
L
E
ZONE 2
N
1
2
SL
L
E
ZONE 3
N
1
2
SL
L
N
YES
ZONE 4
N
1
E
2
SL
L
E
ZONE 5
N
1
2
SL
L
ZONE 6
N
1
E
2
SL
L
E
E
A2
L
ZONE 7
1
N
2
A1
SL
UFH
ZONE 8
N
1
2
SL
RAD
HEAT
ENABLE
LS
2
UFH
MAINS
PUMP
SUPPLY
LR
L
IN OUT IS
VOLT FREE
L
E
N
UFH PUMP
BOILER
N
UFH VALVE
GR OR
L
L
L
E N
N
ZONE 1
L
ZONE 1
L
N
N
L
N
L
ZONE 2
L
N
L
ZONE 3
L
L N
N
ZONE 4
ZONE 3
ZONE 2
N
N
ZONE 4
L
L
N
ZONE 5
N
ZONE 6
L
L
N
ZONE 6
ZONE 5
N
ZONE 7
N
L
ZONE 8
L
L
N
N
L
L
N
ZONE 8
ZONE 7
N
L
L
N
N
L
L
N
N
N
neoStat
(Connected to Zone 8)
LN
230V AC Supply
LN
LN
LN
ZONE 2
ZONE 3
ZONE 4
ACTUATOR
230V
ACTUATOR
230V
ACTUATOR
230V
Radiator Zone Valve
BOILER
(Via
Heating/Hot Water System Fused Spur)
ENABLE
UFH VALVE
Boiler
UFH PUMP
(Heating Enable Terminals)
ZONE 1
ACTUATOR
230V
PLEASE ADD LINK TO GR AND OR IF
VALVE IS NOT FITTED
RADIATOR
VALVE
VALVE WITH
Zone 8 Isolation Switch
ENDSWITCH
If set to YES, Zone 8 enables the Boiler Pump
and Valve.
If set to NO Zone 8 is isolated.
PL
SL
PL
SL
PERMANENT LIVE
SWITCH LIVE
This Equipment should be installed by an appropiately qualified/ registered electrician.
Fully read the instructions for proper wiring before applying power.
The warranty does not cover damage from improper
wiring or installation.
UFH Manifold
(Using 230v Actuators)
Standard Products
8 Zone Wiring Centre
Part Ref: Heatmiser UH8
UH3
neoStat (Heat Mode)
Part Ref: neoStat
Stylish Thermostats For Modern Living
neoStat (Timer Mode)
Part Ref: neoStat
neoHub
Part Ref: neoHub
27
To Boiler
Enable
ZONE 8 TYP E
E
L
NO
UH3
L
2
ZONE 8
FUSE
Heating or Manifold
ValveMAINS
5A FUSE
N A1 A2 - R T 1 R T 2
SL
1
ZONE 7
L
Central Control
Designed to give Central Control within your home
Designed to work with our 12v Network Thermostats, the Heatmiser Touchpad provides central control of your home heating system.
Headline
Information
Key
Features
Central Control
Home and Away
Holiday
Temperature Hold
Part Ref: Heatmiser TouchPad
This feature gives you a simple
Use this function to hold
a desired temperature
Up to 32 rooms can be
controlled from the full colour
TFT Display meaning that
walking around each room to
turn up or down the heating
is a thing of the past.
system whilst you are away.
On your return, pressing the
Home button will re-enable the
system. Ideal when you have a
holiday home and are not sure
when you will return.
Use the holiday feature to
put the heating into frost
mode whilst you are away.
At the end of the holiday,
each room will revert back
to the programmed time,
ensuring your home is warm
on your return.
Display
TouchScreen 4.3” TFT
Colour LCD
Number Of Zones
32 (Max)
Titles
for unexpected activities.
Apply to a single or multiple
rooms.
Copy Facility
Auto GMT Correction
Gives the ability to store a
set of comfort levels for a
group of rooms. This setting
can be applied as and when
required, for example at the
start of a new shift.
Save time - copy comfort
levels between rooms.
Automatically adjusts
the clocks in all of the
thermostats at the start of
summer and winter time.
History
USB Export
Key Lock
The TouchPad will store hours
of temperature history.
The temperature log can
be exported via the USB
connection.
Lock each thermostat to
prevent misuse.
Hot Water Boost
Quick View
Auto Time Sync
Use the hot water boost to
quickly override the hot water
settings.
See at a glance the
current thermostat status
throughout your building.
Syncronises all of the
thermostat clocks on the
network.
Give each room a title
Passcode Protect
When enabled, the user must
enter a passcode in order to
access the system.
Central Control
28
Intuitive User Interface
Interfac
Central Control
Stylish Thermostats For Modern Living
Temperature Hold
Home & Away
29
Central Wiring Switch Boxes
Multi-zone wiring centres - Designed to Mains
make installation
Thermostatssimple
Compatible Wiring C
Our central wiring switch boxes have been designed to simplify the wiring
process.
Using
our
wiring
centres
your application
that
Our
UH2 and
UH3
wiring
centres
areindesigned
to work means
with our
230v therm
the actuator, boiler and pump connections are wired from a single point. and the UH3 for eight zones.
12v Network Thermostat Wiring Centre
Wireless
230vWiring
8 ZoneCentre
Wiring Centre
230v 4 Zone
230
Part Ref: Heatmiser UH1
Part Ref: Heatmiser UH8-RF
UH2
Part
The UH1 is designed to be used in conjunction with our 12v network
thermostats. The UH1 provides central switching and is therefore ideally
as well as providing an output for a hot water cylinder. On demand from
any zone, a 230v output is provided to switch the relevant zone actuators,
boiler, making it compatible with almost all types of boilers. Up to six actuators
can be connected to each zone. An option is provided to turn zone 8 into a
not enabled when there is a call for heat from zone 8.
The UH8-RF
designed
be used inwith
conjunction
with
our compatible
UH2 canisbe
used in to
conjunction
our mains
thermostats.
The UH3 is desi
wireless
The UH8-RF
provides
switching
andas
is therefore thermostat (DS
The UH2thermostats.
provides central
switching
of up tocentral
four zone
actuators
ideally
next
to the underfloor
heating
manifold.
Eight
zones can be zones can be co
well as situated
providing
an output
for a hot water
cylinder
and the
heating
controlled as well as providing an output for hot water control. On demand zone allows you
from
any zone,
a 230v
is provided to
switch control.
the relevant
is available
to use
zoneoutput
4 for conventional
radiator
Up tozone
six
connections ar
actuators,
underfloor
heatingtopump
and valve. A volt free connection is
actuators can
be connected
each zone.
supplied for the boiler, making it compatible with almost all types of boilers. and valve. A vo
Up to six actuators can be connected to each zone. An external aerial is available
all types of boil
for use when the UH8-RF is being mounted in a metal cupboard or when the
wireless signal is restricted. A software option in the thermostat allows you to valve and boile
configure which zones are underfloor heating and which zones are radiators.
MAINS
SUPPLY
BOILER
BOILER
PRT/HW
MAINS
SUPPLY
PRT
PRT/HW
PRT
PRT
PRT
PRT
PRT
TIM
THER
TIM
THER
T
THERMOSTATS
THERMOSTATS
ACTUATORS
T
ACTUATORS
ZONE 1
ZONE 1
ZONE 2
ZONE 2
ZONE 3
ZONE 3
ZONE 4
ZONE 4
M
MA
SU
SU
HOT WATER HOT WATER
PIPE
PIPE
HOT WATERHOT WATER
HEATING HEATING
THERMOSTAT
THERMOSTAT
THERMOSTAT
THERMOSTAT
VALVE/PUMP
PUMP PUMP
VALVE/PUMP
Heatmiser UH1
UH1
Heatmiser
Central Wiring Switch Boxes
Heatmiser
UH8-RF
Heatmiser
UH1-W
Heatmiser
UH2
Heatmiser
UH2
Heatmiser
UH2
UH1-W
is not suitable
for use in Australia
New Zealand.
UH8-RF
is not suitable
for useand
in Australia.
30
Central
CentralWiring
WiringSwitch
SwitchBoxes
Boxes
e Wiring Centres
Multi-zone
Multi-zonewiring
wiringcentres
centres- Designed
- Designedtotomake
makeinstallation
installationsimple
simple
with our 230v thermostats.
The
new
UH4
is boxes
ideal
for
smaller
systems,
uptoto
four
zones
Our
Our
central
central
wiring
wiring
switch
switch
boxes
have
have
been
been
designed
designed
to
simplify
simplify
thethe
wiring
wiring
process.
process.
Using
Using
ourour
wiring
wiring
centres
centres
in your
in your
application
application
means
means
that
that
thethe
actuator,
actuator,
boiler
boiler
and
and
pump
pump
connections
connections
areare
wired
wired
from
from
a single
a single
point.
point.
Mains Thermostats Compatible Wiring Centres
Our UH4 and UH8 wiring centres are designed to work with our 230v thermostats. The new UH4 is ideal for smaller systems, up to four zones
and the UH8 for eight zones.
230v 8 Zone
Wiring
Centre
12v
12v
Network
Network
Thermostat
Thermostat
Wiring
Wiring
Centre
Centre
Wireless
Wireless
230v
230v
8 Zone
8 Zone
Wiring
Wiring
Centre
Centre
Part Ref: Heatmiser
UH8
Part
Part
Ref:
Ref:
Heatmiser
Heatmiser
UH1
UH1
Part
Part
Ref:Ref:
Heatmiser
Heatmiser
UH8-RF
UH8-RF
UH8 is designed
The UH3
toiswork
with to
ourbe
channel
230v timewith
clock
and
230v Set back
TheThe
UH1
UH1
designed
is designed
tofour
be
used
used
in conjunction
in conjunction
with
our(TM4)
our
12v12v
network
network
TheThe
UH8-RF
UH8-RF
is designed
is designed
to be
to be
used
used
in conjunction
in conjunction
with
with
ourour
compatible
compatible
230v 4 Zone Wiring Centre
230v 8 Zone Wiring Centre
Up
to
thermostat (DS-SB)
but equally
could
be
usedcentral
with
any
230v
room
thermostat.
Upideally
toeight
eight
thermostats.
thermostats.
TheThe
UH1
UH1
provides
provides
central
switching
switching
andand
is therefore
is therefore
ideally
wireless
wireless
thermostats.
thermostats.
TheThe
UH8-RF
UH8-RF
provides
provides
central
central
switching
switching
andand
is therefore
is therefore
Part Ref: Heatmiser UH4
Part Ref: Heatmiser UH8
UH8. On
zones can be controlled from the UH3.
Onboard
boardthe
theUH8
UH3are
aretwo
twoheating
heatingtime
timechannels,
channels,each
each ideally
ideally
situated
situated
next
next
to the
to the
underfloor
underfloor
heating
heating
manifold.
manifold.
Eight
Eight
zones
zones
cancan
be be
zone allows you
towell
specify
which an
time
channel
it
should
follow.
Two additional
time
channel
as well
as
as providing
as providing
an
output
output
for for
a hot
a hot
water
water
cylinder.
cylinder.
OnOn
demand
demand
from
from
controlled
controlled
as well
as well
as providing
as providing
an an
output
output
for for
hothot
water
water
control.
control.
OnOn
demand
demand
connections are
provided
hot
water
control
orto
other
auxiliary
devices.
On
demand
from any from
anyany
zone,
zone,
a 230v
afor
230v
output
output
is provided
is provided
switch
to switch
thethe
relevant
relevant
zone
zone
actuators,
actuators,
from
anyany
zone,
zone,
a 230v
a 230v
output
output
is provided
is provided
to switch
to switch
thethe
relevant
relevant
zone
zone
The UH4 can be used in conjunction with our 230v mains thermostats.
The UH3 is designed to work with our four channel 230v time clock (TM4) and 230v Set back
zone, a 230v output is provided to switch the relevant zone actuator, underfloor heating pump actuators,
actuators,
underfloor
underfloor
heating
heating
pump
pump
andand
valve.
valve.
A volt
A volt
freefree
connection
connection
is is
The UH4 provides central switching of up to four zones as well as
thermostat (DS-SB) but equally could be used with any 230v room thermostat. Up to eight
free
connection
isissupplied
for
the
boiler,
ititboilers.
compatible
with
almost
and valve. AAvolt
voltboiler,
free
connection
supplied
foralmost
the
boiler,
making
compatible
with
almost
boiler,
making
making
it compatible
it compatible
with
with
almost
all types
allmaking
types
of boilers.
of
UpUp
to six
to
six
actuators
actuators supplied
supplied
for for
thethe
boiler,
boiler,
making
making
it compatible
it compatible
with
with
almost
almost
all types
all types
of boilers.
of boilers.
providing an output for hot water, system boiler and pump.
zones can be controlled from the UH3. On board the UH3 are two heating time channels, each
simple
slide
makes
88suitable
for
aaradiator
all types of boilers.
simple
slide
switch
makes
zone
suitable
forcontrolling
controlling
radiator
zone.
cancan
beAAbe
connected
connected
toswitch
each
to each
zone.
zone.
Anzone
An
option
option
is provided
is provided
to turn
to turn
zone
zone
8 into
8 into
a zone.
a
UpUp
to six
to six
actuators
actuators
cancan
be be
connected
connected
to each
to each
zone.
zone.
An An
external
external
aerial
aerial
is available
is available
When used for underfloor heating, an option is available to use
zone allows you to specify which time channel it should follow. Two additional time channel
When used for controlling radiators, zone 8 does not enable the underfloor heating pump,
for for
useuse
when
when
thethe
UH8-RF
UH8-RF
is being
is being
mounted
mounted
in ainmetal
a metal
cupboard
cupboard
or when
or when
thethe
zone 4 for conventional radiator control. Up to six actuators
connections are provided for hot water control or other auxiliary devices. On demand from any
Up
to
actuators
can
be
connected
to
each
zone.
valve and boiler.
Upenabled
tofour
four
actuators
can
be
connected
to
each
zone.
notnot
enabled
when
when
there
there
is
aiscall
a call
for for
heat
heat
from
from
zone
zone
8. 8.
wireless
wireless
signal
signal
is restricted.
is restricted.
A software
A software
option
option
in the
in the
thermostat
thermostat
allows
allows
youyou
to to
can be connected to each zone.
configure
configure
which
which
zones
zones
areare
underfloor
underfloor
heating
heating
andand
which
which
zones
zones
areare
radiators.
radiators.
and valve. A volt free connection is supplied for the boiler, making it compatible with almost
all types of boilers. A simple slide switch makes zone 8 suitable for controlling a radiator zone.
TIME CLOCK
THERMOSTAT
DIAL TYPE
THERMOSTAT
DIAL TYPE
THERMOSTAT
MAINS
PRT/HW
PRT
SUPPLY
DS-SB
DS-SB
BOILER
TM4
DIAL TYPE
THERMOSTAT
PRT
DS-SB
valve and boiler. Up to four actuators can be connected to each zone.
NO
PRT
YES
VALVE
MAINS
SUPPLY
TO
BOILER
ZONE 1
ZONE 2
THERMOSTATS
ACTUATORS
SUPPLY TO
SUPPLY TO
ACTUATORS
ACTUATORS
UFH
UFH
OR VALVES
PUMP ZONE 1 VALVE ZONE 2 OR VALVES
ZONE 3
ZONE 4
TIME CLOCK
THERMOSTAT
DIAL TYPE
THERMOSTAT
DIAL TYPE
THERMOSTAT
DIAL TYPE
THERMOSTAT
TM4
DS-SB
DS-SB
DS-SB
ZONE 8
NO
YES
SUPPLY TO
ACTUATORS
OR VALVES
VALVE
Heatmiser
Heatmiser
UH1
UH1
Heatmiser
Heatmiser
UH1
UH1
Heatmiser
UH3
Heatmiser
UH8
HOT WATER
THERMOSTAT
HOT WATER
VALVE/PUMP
HEATING
PUMP
PIPE
THERMOSTAT
Heatmiser
HeatmiserUH2
UH4
Stylish Thermostats For Modern Living
ZONE 1
ZONE 2
ZONE 8
Heatmiser
Heatmiser
UH8-RF
UH8-RF
Heatmiser
Heatmiser
UH1-W
UH1-W
UH1-W
UH1-W
is not
is suitable
notnot
suitable
for use
for in
useAustralia
in Australia
and
and
New
New
Zealand.
Zealand.
UH8-RF
UH8-RF
is
is not
suitable
suitable
for
for
useuse
in Australia.
in Australia.
MAINS
SUPPLY
TO
BOILER
UFH
PUMP
UFH
VALVE
SUPPLY TO
ACTUATORS
OR VALVES
SUPPLY TO
ACTUATORS
OR VALVES
SUPPLY TO
ACTUATORS
OR VALVES
Heatmiser
UH3
Heatmiser UH8
31
Stylish Thermostats For Modern Living
Heatmiser UK Ltd
8 & 9 Hurstwood Court, Mercer Way
Shadsworth Business Park, Blackburn
Lancashire. BB1 2QU, England
Tel: +44 (0)1254 669090
Fax: +44 (0)1254 669091
Email: [email protected]
Registered in England: 3747773
www.heatmiser.com
Twitter: @heatmiseruk
Facebook: facebook.com/thermostats
09/15
WEEE Registration Number: WEE/GF0052TQ