Download PTQ ADM Dev Guide - ProSoft Technology
Transcript
PTQ-ADM ♦ 'C' Programmable ‘C’ Programmable Network Interface Module for Quantum 4.4 Configuring the Processor with Unity Pro Developer Guide Connect Your PC to the Processor The next step is to connect to the processor so that you can download the project file. The processor uses this project file to communicate over the backplane to modules identified in the project file. Note: If you have never connected from the PC to your processor before, you must verify that the necessary port drivers are installed and available to Unity Pro. To verify address and driver settings in Unity Pro: 1 Open the PLC menu, and choose STANDARD MODE. This action turns off the PLC Simulator, and allows you to communicate directly with the Quantum or Unity hardware. 2 Open the PLC menu, and choose SET ADDRESS... This action opens the Set Address dialog box. Open the MEDIA dropdown list and choose the connection type to use (TCPIP or USB). ProSoft Technology, Inc. February 20, 2013 Page 41 of 239