Download Appendix D - AutomationDirect

Transcript
Appendix D: Special Relays
A
2
3
D
5
6
7
8
9
10
11
12
13
14
A
B
C
D
D–4
HSIO Pulse Output Relay
SP104
Profile Complete
On when the pulse output profile is completed. (Mode 30)
Communication Monitoring Relay
SP116
CPU port busy Port 2
On when port 2 is the master and sending data.
SP117
Communication error
Port 2
On when port 2 is the master and has a communication error.
SP120
SP121
Communication busy
Option card slot
Communication error
Option card slot
SP540
SP541
SP542
SP543
SP544
SP545
SP546
SP547
SP550
SP551
SP552
SP553
SP554
SP555
SP556
SP557
SP560
SP561
SP562
SP563
SP564
SP565
SP566
SP567
Current = target value
On when the counter current value equals the value in V2320 / V2321.
Current = target value
On when the counter current value equals the value in V2322 / V2323.
Current = target value
On when the counter current value equals the value in V2324 / V2325.
Current = target value
On when the counter current value equals the value in V2326 / V2327.
Current = target value
On when the counter current value equals the value in V2330 / V2331.
Current = target value
On when the counter current value equals the value in V2332 / V2333.
Current = target value
On when the counter current value equals the value in V2334 / V2335.
Current = target value
On when the counter current value equals the value in V2336 / V2337.
Current = target value
On when the counter current value equals the value in V2340 / V2341.
Current = target value
On when the counter current value equals the value in V2342 / V2343.
Current = target value
On when the counter current value equals the value in V2344 / V2345.
Current = target value
On when the counter current value equals the value in V2346 / V2347.
Current = target value
On when the counter current value equals the value in V2350 / V2351.
Current = target value
On when the counter current value equals the value in V2352 / V2353.
Current = target value
On when the counter current value equals the value in V2354 / V2355.
Current = target value
On when the counter current value equals the value in V2356 / V2357.
Current = target value
On when the counter current value equals the value in V2360 / V2361.
Current = target value
On when the counter current value equals the value in V2362 / V2363.
Current = target value
On when the counter current value equals the value in V2364 / V2365.
Current = target value
On when the counter current value equals the value in V2366 / V2367.
Current = target value
On when the counter current value equals the value in V2370 / V2371.
Current = target value
On when the counter current value equals the value in V2372 / V2373.
Current = target value
On when the counter current value equals the value in V2374 / V2375.
Current = target value
On when the counter current value equals the value in V2376 / V2377.
Equal Relays for HSIO Mode 10 Counter Presets
DL05 Micro PLC User Manual, 6th Edition, Rev. C