Download Appendix D - AutomationDirect
Transcript
Appendix D: Special Relays A 2 3 D 5 6 7 8 9 10 11 12 13 14 A B C D D–4 HSIO Pulse Output Relay SP104 Profile Complete On when the pulse output profile is completed. (Mode 30) Communication Monitoring Relay SP116 CPU port busy Port 2 On when port 2 is the master and sending data. SP117 Communication error Port 2 On when port 2 is the master and has a communication error. SP120 SP121 Communication busy Option card slot Communication error Option card slot SP540 SP541 SP542 SP543 SP544 SP545 SP546 SP547 SP550 SP551 SP552 SP553 SP554 SP555 SP556 SP557 SP560 SP561 SP562 SP563 SP564 SP565 SP566 SP567 Current = target value On when the counter current value equals the value in V2320 / V2321. Current = target value On when the counter current value equals the value in V2322 / V2323. Current = target value On when the counter current value equals the value in V2324 / V2325. Current = target value On when the counter current value equals the value in V2326 / V2327. Current = target value On when the counter current value equals the value in V2330 / V2331. Current = target value On when the counter current value equals the value in V2332 / V2333. Current = target value On when the counter current value equals the value in V2334 / V2335. Current = target value On when the counter current value equals the value in V2336 / V2337. Current = target value On when the counter current value equals the value in V2340 / V2341. Current = target value On when the counter current value equals the value in V2342 / V2343. Current = target value On when the counter current value equals the value in V2344 / V2345. Current = target value On when the counter current value equals the value in V2346 / V2347. Current = target value On when the counter current value equals the value in V2350 / V2351. Current = target value On when the counter current value equals the value in V2352 / V2353. Current = target value On when the counter current value equals the value in V2354 / V2355. Current = target value On when the counter current value equals the value in V2356 / V2357. Current = target value On when the counter current value equals the value in V2360 / V2361. Current = target value On when the counter current value equals the value in V2362 / V2363. Current = target value On when the counter current value equals the value in V2364 / V2365. Current = target value On when the counter current value equals the value in V2366 / V2367. Current = target value On when the counter current value equals the value in V2370 / V2371. Current = target value On when the counter current value equals the value in V2372 / V2373. Current = target value On when the counter current value equals the value in V2374 / V2375. Current = target value On when the counter current value equals the value in V2376 / V2377. Equal Relays for HSIO Mode 10 Counter Presets DL05 Micro PLC User Manual, 6th Edition, Rev. C