Download LED Easy Move Mini Beam & Wash RGBW

Transcript
Manual
LED Easy Move Mini
Beam & Wash RGBW
Table of contents
Safety instructions ............................................................................................................................ 3
1.1.
FOR SAFE AND EFFICIENT OPERATION ............................................................................ 3
2. Designated use ................................................................................................................................ 4
2.1.
Overhead installation ............................................................................................................... 5
3. Introduction ....................................................................................................................................... 7
3.1.
Product overview ..................................................................................................................... 7
4. Connections ..................................................................................................................................... 8
4.1.
Electrical connections .............................................................................................................. 8
4.2.
DMX connections .................................................................................................................... 8
4.3.
DMX connection with terminator.............................................................................................. 8
5. Control .............................................................................................................................................. 9
5.1.
Structure of the menu .............................................................................................................. 9
6. DMX chart ...................................................................................................................................... 11
6.1.
DMX mode Standard (19 channels) ...................................................................................... 11
6.2.
DMX mode Basic (17 channels) ............................................................................................ 12
7. Technical data ................................................................................................................................ 13
1.
2 / 16
1. Safety instructions
•
This device is suitable for indoor use (not outdoors) only.
•
•
•
All modifications to the device will void the warranty.
Repairs are to carry out by skilled personnel only.
Use only fuses of the same type and original parts as spare parts.
•
Protect the unit from rain and humidity to avoid fire and electric shocks.
•
Make sure to unplug the power supply before opening the housing.
1.1. FOR SAFE AND EFFICIENT OPERATION
Be careful with heat and extreme temperature
Avoid exposing it to direct rays of the sun or near a heating appliance.
Not put it in a temperature bellow 32°F
32 /0°C, or exceeding 104°F /40°C.
Keep away from humidity, water and dust
Do not place the set in a location with high humidity or lots of dust.
Containers with water should not be placed on the set.
Keep away from sources of hum and noise
Such as transformer motor, tuner, TV set and amplifier.
To avoid placing on un-stable
stable location
l
Select a level and stable location to avoid vibration.
Do not use chemicals or volatile liquids for cleaning
Use a clean dry cloth to wipe off the dust, or a wet soft cloth for stubborn dirt.
If out of work, contact sales agency immediately
Any troubles arose, remove the power plug soon, and contact with an engineer for repairing, do not
open the cabinet by yourself, it might result a danger of electric shock.
Take care with the power cable
Never pull the power cable to remove the plug from the receptacle, be sure to hold the plug. When not
using the device for an extended period of time, be sure to disconnect the plug from the receptacle.
Important:
Damages caused by the disregard of this user manual are not subject to warranty. The dealer
will
ill not accept liability for any resulting defects or problems. Make sure the electrical
connection is carried out by qualified personnel. All electrical and mechanical connections
have to be carried out according to the European safety standards.
3 / 16
2. Designated use
This device was developed for professional use on stages, in discos, theatres etc. The device is only
approved for a connection up to 230V 50/60 Hz AC voltage and only for indoor use.
Regular breaks during operation increase the lifetime of your device.
Avoid convulsions or any form of forceful impact during the installation or the start-up of the device.
Make sure that the device is not exposed excessive heat, humidity or dust at the place of installation.
Take care that no cables are lying around. You would endanger your own safety and also the safety of
a third party.
It is not allowed to operate or store the device in an environment in which spray water, rain, humidity
or fog is expected. Humidity or very high atmospheric humidity could reduce the isolation of the device
and could cause deathly electric shocks. If you use fog devices the device has not be exposed to a
direct smoke jet. There has to be a safety distance of at least 0,5m between this device and the fog
machine. Make sure that the saturation of the fog has to enable a visibility of at least 10m.
The ambient temperature has to be between 0°C and +40°C. Avoid direct sunlight and close proximity
to heaters. You have also to attend it during the transport in closed motor vehicles.
Operate the device not during thunderstorms. Surge voltages could destroy the device. Unplug the
power supply during thunderstorms.
During the installation the use of the mounting bracket is obligatory.
Surrounding objects or surfaces should not be in contact with the device.
Make sure that during the installation and removal of the device the area below the place of
installation is basically cordoned off. This also applies to implementation of service.
The device has basically been protected by a suitable safety.
Make familiar yourself with the functions of the device before start-up. People without the experience
should not handle with the device. The most cause of functional disorder is inappropriate handling.
Do not use chemicals or volatile liquids for cleaning. Use a clean dry cloth to wipe off the dust, or a
wet soft cloth for stubborn dirt.
For transport use the original packing or designated accessory to avoid damages during the transport.
For reasons of safety unauthorized changes are forbidden.
A usage of the device which differs from usages which are described in this manual can cause
damages of the device. In that case the warranty expires. Additional you should notice that every
differed usage is related with dangers and can cause e.g. an electrical short, fire, electric shock or
crash.
4 / 16
2.1. Overhead installation
Danger of life!
You have to observe the regulations of BGV C1 (formerly VBG 70) and
EN60598-2-17
17 Installations are to carry out by skilled personnel only.
The suspension devices have to be build and measured so they can withstand for an hour the tenfold
of the payload without suffering a permanent detrimental deformation.
Basically installation has to be made by using
using a second separate suspension. This can be e.g. a
suitable net. The second suspension must be designed and attached so no part of the installation can
fall down in case of failure.
During construction, reconstruction and deconstruction unnecessary stay in the range of moving
areas, on lightning bridges, under elevated work stations or any other danger zones is forbidden.
The operator is obliged to following safety-related
safety
and mechanical facilities:
-
Before the first start-up
up or after critical changes before restarting it has to be checked by an
expert.
Review in the frame of the inspection test at least all four years by an expert. .
Review by a qualified person at least once a year.
ye
How to carry out the overhead installation:
In tidal fall you should install the device out of the lounge area of people
IMPORTANT! Overhead installation requires a high level of experience. This includes knowledge of
calculating the payload, used installation material and safety inspections of the used material and the
projector whereas the required experience is not limited to this. Do not try to carry out installation
yourself under any circumstances if you are not qualified. Contact a professional installer. An
inappropriate installation can lead to injuries and/or damaged properties.
It is not allowed to install the device in the
th grip area of people.
If the device may hang from the ceiling or from high beams, the use of truss systems is mandatory.
The device may not be installed so it can swing freely in the room.
Please note: Crashing down items can cause serious injuries! Do not install the projector, if you doubt
the safety of a possible installation form!
Before installation make sure that the mounting surface has the ability to carry the tenfold point load of
the own weight of the device.
Mount the device with the mounting-bracket
mounti bracket to your trussing system using an appropriate clamp.
During overhead installation the device must be always secured by a safety rope which is designed to
hold the twelvefold weight of device. Only safety ropes with quick-release
quick release safety fastener elements
may be used. Hang up the safety rope in the hole of the mounting bracket. Direct the rope over the
truss or an appropriate fastening point. Hang up the end in the fastening element and tie up the
locking nut. A safety rope once exposed to failing load or damaged may not be used furthermore.
5 / 16
The maximum drop exceed must not exceed 20cm.
A safety rope once exposed to failing load or damaged may not be used furthermore.
Adjust the desired inclination angle via the mounting bracket and tighten the screw.
6 / 16
3. Introduction
Thank you for buying the LED Easy Move Mini Multi Beam. . It is a powerful device.
For a successful installation and operation, please read this manual carefully.
3.1. Product overview
1. Display
2. Menu
3. Up
4. Down
5. Enter
11. Power out P-Con
6. DMX in XLR 3 pol
7. DMX out XLR 3pol
8. Switch On/Off
9. Fuse
10. Power in P-Con
7 / 16
4. Connections
4.1. Electrical connections
If you wish to change the power supply settings, see the chapter Appendix. Connect the fixture to the
mains with the enclosed power cable and plug. The earth has to be connected.
Cable (EU)
Cable (US)
Pin
International
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green
Green
Earth
4.2. DMX connections
To make a DMX512 connection go ahead like it is described in the picture. Make sure that you
use shielded cable. 3pole or 5pole XLR cables are suitable.
Important! After the last device the line has to be terminated. In order to do this you have to solder
a 120Ω resistor between the pins Data + and Data -. You can solder this end resistor on a 3pin or
5pin XLR: Plug this adapter into the DMX output of the device.
4.3. DMX connection with terminator
Where the DMX cable has to run a long distance or the equipment is operated in an electrically noisy
environment like a disco for installations, we recommend using a DMX terminator. This prevents
corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR
connector with a 120 Ω resistor between pins 2 and 3, which is then plugged into the XLR output
socket of the last device in the series. Please look to the bottom drawings.
8 / 16
5. Control
Press MENU to reach the first menu and use UP/DOWN to get to submenu. To open submenu you
have to press ENTER, here you can also reach other menu items with UP/DOWN buttons, confirm
with ENTER. Press MENU to store your settings.
5.1. Structure of the menu
Menu
Submenu 1
AddreSet
ADD:000512
MotorSet
Submenu2
Function
Setting the DMX address.
PanRev
Yes/No
Activate or deactivate Pan reverse.
TiltRev
Yes/No
Activate or deactivate Pan reverse.
PanAdj
000-255
Fine adjusting of Pan.
TiltAdj
000-255
Fine adjusting of Tilt.
Encoder
Yes/No
Activate or deactivate the feedback.
PanMode
540/630
Choose the required Pan mode.
GoboAdj
000-255
Setting of the Zoom.
AutoProg
Alone/Master
Choose an automatic mode.
Mic Cont
Alone/Master
Choose a sound-to-light mode.
MICSensy
000-100%
Setting the microphone sensitivity.
ChanTest
NoSigSet
Pan
000-255
Manual setting of pan.
Pan1
000-255
Manual setting of Pan fine.
Tilt
000-255
Manual setting of Tilt.
Tilt1
000-255
Manual setting of Tilt fine
Speed
000-255
Manual setting of the speed.
R1
000-255
Manual setting of dimmer red for LED 1 + LED 3.
G1
000-255
Manual setting of dimmer green for LED 1 + LED 3.
B1
000-255
Manual setting of dimmer blue for LED 1 + LED 3.
W1
000-255
Manual setting of dimmer white for LED 1 + LED 3.
R2
000-255
Manual setting of dimmer red for LED 2 + LED 4.
G2
000-255
Manual setting of dimmer green for LED 2 + LED 4.
B2
000-255
Manual setting of dimmer blue for LED 2 + LED 4.
W2
000-255
Manual setting of dimmer white for LED 2 + LED 4.
Zoom
000-255
Manual setting of the zoom
Stro
000-255
Manual setting of the strobe.
Lumi
000-255
Manual setting of the dimmer.
Colo
000-255
9 different color macros.
Warm
000-255
Different presets of color temperatures.
SavScene
Choosing the automatic mode.
Auto
Choosing the sound-to-light mode.
Music
No mode is chosen.
Close
Choosing the stored scene.
Scene
Choosing the automatic mode.
Basic
Mode Set
User
Choosing the required DMX mode.
Standard
9 / 16
UserMode
Pan
01-19
Manual assignment of the DMX channel for Pan.
Pan1
01-19
Manual assignment of the channel for Pan fine.
Tilt
01-19
Manual assignment of the DMX channel for Tilt.
Tilt1
01-19
Manual assignment of the DMX channel for Tilt fine.
Spee
01-19
Manual assignment of the DMX channel for speed.
R1
01-19
Manual assignment of the DMX channel for dimmer
red for LED 1 + LED 3.
G1
01-19
Manual assignment of the DMX channel for dimmer
green for LED 1 + LED3.
B1
01-19
Manual assignment of the DMX channel for dimmer
blue for LED 1 + LED 3.
W1
01-19
Manual assignment of the DMX channel for dimmer
white for LED 1 + LED 3.
R2
01-19
Manual assignment of the DMX channel for dimmer
red for LED 2 + LED 4.
G2
01-19
Manual assignment of the DMX channel for dimmer
green for LED 2 + LED4.
B2
01-19
Manual assignment of the DMX channel for dimmer
blue for LED 2 + LED 4.
W2
01-19
Manual assignment of the DMX channel for dimmer
white for LED 2 + LED 4.
Zoom
01-19
Manual assignment of the DMX channel for zoom.
Stro
01-19
Manual assignment of the DMX channel for the
strobe.
Lumi
01-19
Manual assignment of the DMX channel for
dimmer.
Colo
01-19
Manual assignment of the DMX channel for color
macros.
Warm
01-19
Manual assignment of the DMX channel for color
temperature.
Auto
00-08
Manual assignment of the DMX channel for
automatic mode.
Save Set
Store the manual assignments.
ResetDef
Reset.
Versions
Shows the current software version.
10 / 16
6. DMX chart
6.1. DMX mode Standard (19 channels)
Channel
Value from
Value to
Function
1
0
255
Pan
2
0
255
Pan fine
3
0
255
Tilt
4
0
255
Tilt fine
0
225
Speed Pan/Tilt fast-slow
226
235
No function
5
236
255
Highest speed.
6
0
255
Dimmer red LED 1 + LED 3
7
0
255
Dimmer green LED 1 + LED 3
8
0
255
Dimmer blue LED 1 + LED 3
9
0
255
Dimmer white LED 1 + LED 3
10
0
255
Dimmer red LED 2 + LED 4
11
0
255
Dimmer green LED 2 + LED 4
12
0
255
Dimmer blue LED 2 + LED 4
13
0
255
Dimmer white LED 2 + LED 4
14
Zoom (narrow to wide)
Strobe
15
16
0
16
No function
17
255
Strobe
0
255
Dimmer
Color Macros
17
18
19
0
55
No function
56
75
Red
76
95
Green
96
115
Blue 1
116
135
White
136
155
Pink
156
175
Orange 1
176
195
Blue 2
196
215
Blue 3
216
255
Orange 2
0
55
No function
56
255
Different presets of color temperatures.
0
75
No function
76
255
Automatic programs
11 / 16
6.2. DMX mode Basic (17 channels)
Channel
Value from
Value to
Function
1
0
255
Pan
2
0
255
Tilt
0
225
Speed Pan/Tilt fast-slow
226
235
No function
236
255
Highest speed.
4
0
255
Dimmer red LED 1 + LED 3
5
0
255
Dimmer green LED 1 + LED 3
6
0
255
Dimmer blue LED 1 + LED 3
7
0
255
Dimmer white LED 1 + LED 3
8
0
255
Dimmer red LED 2 + LED 4
9
0
255
Dimmer green LED 2 + LED 4
10
0
255
Dimmer blue LED 2 + LED 4
11
0
255
Dimmer white LED 2 + LED 4
12
0
255
Zoom (narrow to wide)
3
Strobe
13
14
0
16
No function
17
255
Strobe
0
255
Dimmer
Color Macros
15
16
17
0
55
No function
56
75
Red
76
95
Green
96
115
Blue 1
116
135
White
136
155
Pink
156
175
Orange 1
176
195
Blue 2
196
215
Blue 3
216
255
Orange 2
0
55
No function
56
255
Different presets of color temperatures.
0
75
No function
76
255
Automatic programs
12 / 16
7. Technical data
Power supply
Voltage
AC 100-240 V; 50/60 Hz
Power consumption max.
70 W
Light source
LM type
4in1 Osram LED
Color spectrum
RGBW
Power
60 W
Number / Power
4 x 15 W
Connections
Strom in
P-Con
Strom out
P-Con
XLR in/out
3pol
Pan
540 / 630
Tilt
235°
Controlling
Sound-to-light
Yes
Automatic
Yes
Master-Slave
Yes
DMX512
Yes
Number of canals
17 / 19 channels
Hardware
Protection class
IP20
Suitability
Indoor
Dimensions (L/B/H)
301 x 236 x 134 mm
Weight
4,37 kg
13 / 16
14 / 16
15 / 16
Importer:
B & K Braun GmbH
Industriestraße 2
D-76307 Karlsbad
www.bkbraun.com
[email protected]
16 / 16