Download PS Service Manual
Transcript
MAINTENANCE MANUAL PS SERIES MODELS: PS-3000, PS-6000, PS-12K, PS-30K PS-3000S, PS-6000S, PS-15KS, PS-30KS CONTENTS 1. INTRODUCTION 2. SPECIFICATIONS 2.1 SYSTEM BLOCK DIAGRAM 2.2 PHYSICAL LAYOUT OF ELECTRICAL CONNECTION 2.3 GENERAL SPECIFICATIONS 3. INITIAL SETUP 3.1 INTERNAL FUNCTION AND SETTING METHODS 3.2 AUTO AND DEALER CALIBRATION PROCEDURES 3.3 DISABLE CALIBRATION WITH DIP SW. (S1) 3.4 OFFSET AND SPAN VALUE DATA 3.5 FLOW CHART 4. TROUBLE SHOOTING 4.1 TROUBLE SHOOTING LOOP 4.2 PARTS AND COMPONENTS TROUBLE SHOOTING 5. ELECTRICAL CIRCUITRY 5.1 SCHEMATICS 5.2 PCB LAYOUT 6. BILL OF MATERIAL 7. APPENDIX APR. 2001 REV 1 Specifications and Function Subject to Change without Notice 1 1. INTRODUCTION The PS series is designed according to IP-65 protection requirements to assure working properly under toughest environment. Ender users should be advised not to undertake any troubleshooting except those listed on the operation manual. This maintenance manual containsof certain information that may result in fraudulent use. Do not release any part of this manual to any end users or un-authorized persons. The internal DIP S/W should beso set to prevent un-authorized settings or alternations. Should a load cell has been replaced, make sure that the protection devices are properly set. After servicing, it is necessary to go throughall tests and procedures to ensure the scale meets all the meteorological and approval requirements. Here are some features of the PS series 1. 2. 3. 4. 5. 6. 7. 8. Zero indicator Tare indicator Negative value indicator Subtractive tare function. Power on zero function. Manual zero function. Auto Power Saving Function Dual power: - By built-in rechargeable battery and external AC/DC power adaptor. 9. Low battery warning signal. 10. Dual color charge status indicator. 11. 2 Types of Calibration 12. Overload protection against positive and negative force 13. AC/DC power adaptor, adjustable feet included. 14. Dip Switch to prevent end-user calibration 15. Optional EL backlight facility. 2 2. SPECIFICATION 2.1 SYSTEM BLOCK DIAGRAM LCD LCD DRIVER LOAD CELL E+ ES+ S- A/D UNIT CPU with ROM POWER SUPPLY: AC ADAPTOR (9V/500mA) RECHARGEABLE BATTERY (6V 4Ah) KEYBOARD (8 KEYS) Description: When an article is placed on the platter, the load of the article is applied to the load cell inside the scale. The resistance to the excitation current in the strain gauge will then changed and the analog output signal varies. It is amplified and digitized continuously by the A/D converter into a digital signal. Subsequently, the resulting count is processed and managed by the CPU. The CPU refers to the instructions from the keyboard, and then conveys the output data to LCD driver, which formats the data into readout on the display panels. 3 2.2 PHYSICAL LAYOUT OF ELECTRICAL CONNECTION LOAD CELL DC JACK RECHARGEABLE BATTERY 6V 4Ah MAIN BOARD 4 2.3 GENERAL SPECIFICATION 2.3.1 Overall View 5 2.3.2 Overall Dimension: 280(W) x 330(D) x 455(H)mm 2.3.3 Platter Size: 280 X 330mm 2.3.4 Model Specifications Model Number PS-3000 PS-6000 PS-12K PS-30K PS-3000S PS-6000S PS-15KS PS-30KS Tare Range Power on Zero Range Manual Zero Range Operation Environment Power Consumption Power Source Weight Capacity 3000g 6000g 12kg 30kg 3000g 6000g 15kg 30kg Division 0.5g 1g 2g 5g 1g 2g 5g 10g Full Tare ¡10%F.S. ¡2%F.S. 0o~40oC (32o~104oF), Non-condensed. R.H.¡ 85% Normal = 0.1W Charging = 5W Built-in Rechargeable Battery, or AC/DC Power Adaptor:DC9V 500mA Net/Gross Weight: 8.4/9.4kg 2.3.5 Main Components Used Microprocessors: 89C51 Crystal Oscillator: 6MHz Display Device: WTN Liquid Crystal Display 5 1/2 digits,25mm height Load Cell Used: PS-3000,6000,12K,30K TEDEA 1022 Model PS-3000S,6000S,15KS,30KS NMB CB030 Model Load Cell Capacity: PS-3000 = 7kg PS-6000 = 10kg PS-15 = 20kg PS-30 = 35kg 6 2.3.6 Analog Specification Input sensitivity: 2mV/V Zero Drift: 0.02% R.O./10oC Zero Balance Range: ¡2% of rate capacity Load Cell Excitation Voltage: DV5V A/D Conversion Speed: 10 times/second Internal Resolution: 30000 7 3. INITIAL SETUP 3.1 INTERNAL FUNCTIONS AND SETTING METHODS INTERNAL FUNCTION TABLE Function 1 2 3 4 HOW a. b. c. d. e. f. g. h. Symbol F.1 F.2 F.3 F.4 Description Span value reading and dealer calibration Full display segment and max. capacity check Check offset value and scale configuration Auto power off setting TO ENTER THE REQUIRED FUNCTION MODE Turn scale off. Press and hold TARE, then turn scale on. Scale display F.1 Press TARE until the required function number ap pears. Press MODE Press MODE until the required setting appears. Press TARE to confirm. Repeat step c to f for other function setting, or Press ZERO to save settings and return to normal operation. F.1 Span Value Reading and Dealer Calibration a. Simply enter F.1 to read the A/D counts. b. Press ZERO to clear the A/D counts, apply test mass onto platter, the span value of test mass will be displayed. c. Refer to Dealer Calibration procedures for dealer calibration. F.2 Display Segment and Rated Capacity & Division Check When function is entered, all segments will be displayed. Check and make sure that no segments are missed. F.3 Total Internal Count Checking and Scale Configuration a. Enter F.3, scale displays the Offset Value when unloaded. b. Apply extra load onto platter, the total internal count value will be displayed. SELECT WEIGHT UNITS a. Press and hold MODE until the weight unit appears. b. To employ all (metric and pound) weight units, press MODE until lb appears. To disable pound weight unit, press MODE until kg appears. c. Press ZERO to save setting and back to normal operation status. 8 F.4 Auto Power Off Setting Two modes are available: (Default=4_OFF) 0._OFF = Auto Power Off function is disabled. 4._OFF = Scale will automatically be turned off after 4minutes unused. 3.2 AUTO AND DEALER CALIBRATION PROCEDURES ACCEPTABLE LOAD FOR AUTO AND DEALER CALIBRATION Model Number External Acceptable Auto and Dealer Division Calibration Load PS-3000 1/6000 *2kg 1kg PS-6000 1/6000 *4kg 2kg PS-12K 1/6000 *10kg 5kg PS-30K 1/6000 *20kg 10kg PS-3000S 1/3000 *2kg 1kg PS-6000S 1/3000 *4kg 2kg PS-15KS 1/3000 *10kg 5kg PS-30KS 1/3000 *20kg 10kg * Recommended calibration load Dealer Calibration Procedures: 1. Turn scale off. 2. Press and hold TARE, then turn scale on. 3. Scale displays F.1 4. Press MODE 5. Scale displays offset value 6. Press ZERO 7. Press TARE 8. Press ZERO 9. Press TARE 10.Press ZERO, scale displays a circle at the right hand of the display. It means the scale is ready for dealer calibration. Make sure that the figure being displayed is =0 or 1, If not, press ZERO again. 11.Load calibration either load as listed on above table. 12.When value displayed is stable, press MODE. 13.Wait until the scale starts countdown. 14.Calibration completed and scale is ready for operation. Auto Calibration Procedures: 1. 2. 3. 4. Turn scale off Press and hold MODE, then turn scale on. Scale displays CAL? Press MODE 9 5. 6. 7. 8. Scale displays LOAD XXXX or XXXX Load calibration load according to above table. Wait until the scale display DONE and starts count down. Calibration completed and scale is ready for operation. 3.3 DISABLE CALIBRATION AND AVOIRDUPOIS WEIGHT UNITS WITH DIP SW. (S1) The DIP SW.#1 is used to control calibration and avoirdupois weight units. Push this switch to ON position to disable calibration. 3.4 OFFSET AND SPAN VALUE DATA OFFSET AND SPAN VALUE DATA TABLE Model Number Offset Value (Thousand) PS-3000 10~14 PS-6000 10~14 PS-12K 10~14 PS-30K 10-14 PS-3000S 10~14 PS-6000S 10~14 PS-15KS 10~14 PS-30KS 10-14 Span Value(Thousand) at Various Load Applied 10~15 10~15 10-15 10~15 10~15 10~15 10-15 10~15 at at at at at at at at 1kg 2kg 5kg 10kg 1kg 2kg 5kg 10kg 20~30 20~30 20-30 20~30 20~30 20~30 20-30 20~30 at at at at at at at at 2kg 4kg 10kg 20kg 2kg 4kg 10kg 20kg Offset Control VR1 VR1 VR1 VR1 VR1 VR1 VR1 VR1 Trimmer Trimmer Trimmer Trimmer Trimmer Trimmer Trimmer Trimmer Span Control(Ohm) R1A 47K 40K 25K 25K 47K 40K 25K 25K READING OFFSET VALUE 1 Turn scale off 2 Remove all load from platter 3 Enter F.3 and read the offset value READING SPAN VALUE 1 Turn scale off 2 Remove all load from platter 3 Enter F.1 4 Press ZERO 5 Apply load to platter. Span value according to load applied will be displayed. HOW TO ADJUST OFFSET VALUE In case the offset value is out of range, adjust the trimmer located at VR1 on the main board to obtain correct offset value. HOW TO ADJUST SPAN VALUE The span value is controlled by resistor located on R1A, standard resistor value of R1A is listed on the above table. If the required span value is not attained, then change R1A resistor according to either case below: Span value too low: Increase the resistance of R1A. Span value too high: Decrease the resistance of R1A. 10 3.5 FLOW CHART 3.5.1 Auto Calibration (for end-user) START DISPLAY "YES" PRESS "MODE" & "ON/OFF" LCD PANORAMA DISPLAY "LOAD" DISPLAY FULL SCENE DISPLAY "XXXX" RELEASE "ON/OFF" KEY DISPLAY "or" CALIBRATING? DISPLAY "CAL.?" DISPLAY "XXXX" RELEASE "MODE" KEY PUT A ASSIGNED WEGHT ON PLATTER "MODE"=YES "ZERO" =NO PRESS "MODE" OR "ZERO" KEY NO YES CORRECT WEIGHT ASSIGNED? CALIBRATING? YES DISPLAY "DONE" NO DISPLAY "no" DISPLAY "99999" DISPLAY "99999" DISPLAY "00000" DISPLAY "00000" DISPLAY " 0" NO WEIGHT STILL ON THE PLATTER? YES STANDBY FOR OPERATION DISPLAY "XXXX" "XXXX"=ASSIGNED WEIGHT 11 3.5.2 Function Test (for technicians only) START PRESS "TARE" & "ON/OFF" LCD PANORAMIC VIEW RELEASE "ON/OFF" KEY S RELEASE "TARE" KEY 99999 COUNT DOWN F1 11111 F1 00000 O ther " MODE " PRESS K E Y ? S <- 0.00 kg "TARE" l F2 STANDBY FOR OPERATION F2 12 l D ISPLAY "X X X X ". xxxx:Show offset NO k PRESS "ZERO " ? YES TEST KEYBOARD CAL. LOOP A /D _ > 0 + / - 3 counts k k :key code 0 K ey in Private C ode NO PRESS K E Y C O D E :1 ,2 ,1 ,2 SW IT C H OFF ? NOTE : ¡ @ YES 1: TARE key NO END LEGITIMATE PROCEDURE 2: ZERO key C j YES 0 0 " 0 " A ccept Private C ode D ISPLAY SPA N V A L U E PUT ON THE ASSIGNED WEIGHT DIP SW. #1 > ON? NO j YES NO PRESS "M O D E " ? YES k NO WEIGHT ASSIGNED C YES DONE S 13 F2 F2 Other s "TARE" PRESS KEY? "MODE" X X .X X :Capacity AXX.XX L.C.D PANORAMIC VIEW "M O D E" other PRESS KEY? F3 S "TARE" F3 F1 other S "TARE" PRESS K E Y ? F4 "MODE" WEIGHT UNIT CHANGED: kg<--->kg/lb 14 F4 F4 " TARE " other F1 PRESS K E Y ? "M ODE A uto shut-off w hen notin use for 4 m in. 4_oFF S other PRESS K E Y ? "TA R E " F1 "M ODE " 0_oFF No A uto shut-off 15 4. TROUBLE SHOOTING 4.1 TROUBLE SHOOTING LOOP POWER ON NO DISPLAY COUNT DOWN? CHECK POWER SUPPLY, CPU,LCD,KEYBOARD OK COUNTS AND THEN ZERO? OK GHOST PROPER READOUT? CHECK POWER SUPPLY,LCD,LCD DRIVER IC,R18~21 OK INCORRECT RE-CALIBRATE THE SCALE CORRECT READOUT? OK DISPLAY RANDOM FIGURE CHECK CPU,LCD, LCD DRIVER IC SHOW ¡00000¡ CHECK LOAD CELL, A/D UNIT,OFFSET VALUE UNSTABLE CHECK PLATTER STOPPER,LOAD CELL,A/D UNIT, BAD SOLDERING CAN¡T REACH THE FULL CAPACITY CHECK PLATTER STOPPER,LOAD CELL,OFFSET VALUE NORMAL OPERATION 16 4.2 PARTS AND COMPONENTS TROUBLE SHOOTING 4.2.1 Power Supply Checking 4.2.1.1 Relevant parts: Main Board (PS-10-X) Q1 (C1061) ZD1(8.2V) BR1(W04/1A) Q4 (A1515) Q2 (C945) Q5 (A733) R30(1.2 ohm, 1/2W) U1 (IC 4027) U3 (LM358) ZD2(3.3V) 17 Description: 1) AC Adaptor: This AC Adaptor provides power for DC9~12V,500 mA. 2) Battery: Built-in Rechargeable Battery 6V/4Ah 3) How Battery is charged completely? The charging voltage is regulated by Q1 (C1061) and ZD1 (8.2V) for about 7 volts. The charging current will go down automatically when voltage reached. Q2(C945) and R30(1.2R, 1/2W) provide Over-Current protection. 4) +5V power drives digital circuit system. +5V power is created by U3B(LM358) with negative feedbacktechnology. 5) +5V & -5V power drives analog circuit system. U12(AIC1722-50) and U11(IC 7660) are used to create +/-5V power. 6) Auto-off: If the scale is set on 4_oFF or even under LO-BAT situation, after some minutes the CPU will release apositive pulse signal to change the U1(IC 4027) output state then makes Q4 cut-off, the scale will be shut off immediately. 7) Low Power Detection: U3A(LM358) is acted as a voltage comparator. When battery power is less than 5.5V, it will release a low potential signal to CPU, then CPU will instruct LCD display to show LO-BAT symbol. 4.2.1.2 Input voltage: 5.5V or higher Check and recharge battery if voltage less than 5.5V. Check DC-JACK or AC Adaptor if been defective. 18 4.2.1.3 System voltage (Vcc): 5V +/- 10% Check that the system voltage is within 5V +/- 10% a) less than 4.5V, the CPU may not work properly. b) more than 6V, ghost will appear on LCD. 4.2.2 Platter Stopper Checking The platter device shall not touch anything around itself during operation. Check that the platter is not contacted with the upper (no load) and/or lower (with load) stopper. 4.2.3 LCD Display Checking 4.2.3.1 Check that it is soldered and connected properly between LCD and driver IC (uPD7225), driver IC (uPD7225) and CPU. 4.2.3.2 Check whether LCD is broken. 4.2.4 CPU Checking 4.2.4.1 Check that all pins are seated properly into the socket. 4.2.4.2 Check that the Crystal Oscillator works. 4.2.4.3 Check the RESET is normally low. 4.2.5 A/D Unit Checking 4.2.5.1 Check that the +3.3V & +/-5V powers are correctly fed to the A/D unit. 4.2.5.2 Check that the signal output of loadcell is normal. 4.2.5.3 Check OP. Amplifiers & A/D Converter (AD7715). When no error is found with the above checking procedures, the trouble can be caused on the loadcell or the PCB itself. Replace a new one could be better to identify the defective. In this way, the readout of weight would be varied because of the output voltage of loadcell and different span value, so re -calibration is required after this replacement. 19 5. ELECTRICAL CIRCUITRY 5.1 SCHEMATICS 20 21 22 5.2 PCB LAYOUT PS-10-2 BOTTOM OVERLAY PS-10-2 TOP OVERLAY 23 PS-10-2 PS-10-2 TOP LAYER BOTTOM LAYER 24 6. BILL OF MATERIAL STRUCTURE Parts No. Description A00590***** A0950000011 A5001000312 A60******** F0001PS1100 F0001PS1000 F0002PW0000 F0003PS1100 F0003PS1101 F0003PS1102 F0003PS1103 F0004PS1000 F0009000035 F0029PS1000 G0004BW1000 G0004PS1000 G0004PW0100 G0005BW1000 G0030PS1020 X1PS1000000 Z0011200420 Z0014100508 Z0014100625 Z0015100406 Z0015100410 Z6BW1000010 A0906000210 A0950000010 A1204040250 A1208020351 Specification LOADCELL 1022 or CB030 CABLE CONNECTOR LTW-6FM-90 MOVABLE BUSHING PS SERIES (AMB-1S) ADAPTOR *** V/ 9V 500mA S/S HOUSING(UPPER) PS SERIES S/S HOUSING(UNDER) PS SERIES S/S PLATTER PW SERIES LOAD CELL SUPPORT ¢ PW SERIES LOAD CELL SUPPORT ¢ PW SERIES LOAD CELL SUPPORT ¢ PS SERIES LOAD CELL SUPPORT ¢ PS SERIES S/S PILLAR PS SERIES, L SHAPE S/S PLATE PS SERIES, PILLAR SUPPORT S/S ADJUSTABLE FEET COVER PS SERIES ADJUSTABLE FEET BW SERIES PLASTIC FOOT £ 8-10h RUBBER TUBE PW SERIES PLATTER BEARING RUBBER BW SERIES RUBBER PLUG PS SERIES OPERATION MANUAL PS SERIES S/S SCREW (Ny -Lock) M4x20 SCREW M5x8 S/S SCREW M6x25 S/S SCREW M4x6 S/S SCREW M4x10 PACKING MATERIAL PM/BW SERIES D C JA C K S C D -21 C O N N E C T O R (W A TER P R O O F) LTW-6MS-C WIRE ARRAY 4 PIN 25cm BATTERY WIRE ARRAY 2PIN 35 cm, SINGLE HOUSING INDICATOR STRUCTURE Parts No. Description Specification A1600060400 C1PS1****** C1PS1000000 E1PS1000011 F0003PS0000 F0005PS1000 F0005PS1100 F0013FS0000 F0022000010 G0030FS0000 6V / 4Ah PS SERIES PS SERIES (8 HOLES) PS-10-X PS SER IES PS SERIES PS SERIES NBS/FS/1705/PS FS INDICATOR FIXING DC JACK SC D -021 RECHARGEABLE BATTERY OVERLAY PANEL PC PC PLATE P.C.B. KIT S/S M O U N TIN G PLATE S/S DISPLAY H O U SIN G S/S DISPLAY H O U SIN G S/S BATTERY PLATE S/S ADJUSTABLE FEET RUBBER PLUG Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 4 4 1 4 4 1 1 6 6 4 6 10 1 1 1 1 1 Qty 1 1 1 1 1 1 1 1 2 1 Remark UPPER UNDER UPPER UNDER Remark FRONT REAR 25 G0030PS1000 G0030PS1010 G0030PS1030 Z0010000306 Z0010000308 Z0010001305 RUBBER PACKING RUBBER FRAME RUBBER PACKING SCREW SCREW SCREW PS SERIES PS SERIES PS SERIES £ 21(£ 15.3)x5L M3x5 M3x8 3x5 TAPPING 6 1 1 6 2 5 MAINBOARD Parts No. Description Specification E0PS1000000 A0202093461 A0203077450 A0205040270 A0206000071 A0206000072 A0206003580 A0207017223 A0208072250 A0300000040 A0401001060 A0401007330 A0401009450 A0401015150 A0501004002 A0501004148 A0502000001 A0503020033 A0503020082 A0625050000 A0701108016 A0701477016 A0701106016 P.C.B. I.C. I.C. I.C. I.C. I.C. I.C. VOLTAGE REGULATOR I.C. I.C. SO C K E T TRANSISTOR TRANSISTOR TRANSISTOR TRANSISTOR D IO D E D IO D E BRIDGE RECTIFIER ZEN ER ZEN ER L.E.D. CAPACITOR (EC) CAPACITOR (EC) CAPACITOR (EC) PS-10-X 93C46 AD7715AN-3 4027 OP-07CP OP-177 LM358N AIC-1722-33CZT UPD7225G 40 PIN 2SC1061 A733 2SC945 2SA1515 1N4002 1N4148 W 04/1A 3.3V 1/2W 8.2V GREEN/RED,ROUND,5 £ 1000uF/16V 470uF/16V 10uF/16V 1 1 1 1 1 1 1 1 1 1 1 3 2 1 1 1 1 1 1 1 1 1 8 A0701106016 A0713474063 A0720103101 A0730104050 CAPACITOR CAPACITOR CAPACITOR CAPACITOR 10uF/16V 0.47uF/63V(105) 0.01uF/100V(103J) 104Z 6 3 1 28 A0740020050 A0803041002 A0803042502 A0803044002 A0804041003 A0804041272 A0805020120 CAPACITOR (CC ) METAL FILM RESISTOR METAL FILM RESISTOR METAL FILM RESISTOR METAL FILM RESISTOR METAL FILM RESISTOR CARBON FILM RESISTOR 20pF 10K£ 25K£ 40K£ 100K£ 27K£ 1.2£ 2 2 1 1 5 1 1 (TC) (MEF) (PEI) (M LC) 1/4W 1/4W 1/4W 1/4W 1/4W 1/2W Qty Remark U8 U6 U1 U5 U4 U3 U2 U9 U7 Q1 Q3,5,6 Q2,7 Q4 D2 D1 BR1 ZD2 ZD1 LED 1 C30 C32 C16,20,24,25,27 28,36,47 C13,37,39,42,43,44 C7,8,10 C1 C 2-6,9,11,12,14,15, 17,21-23,26,29,31, 33-35,38,40-41,45, 46,48-50 C18-19 R8,11 R7 R10 R2-6 R44 R30 26 A0805021101 A0805041102 A0805041103 CARBON FILM RESISTOR 100£ CARBON FILM RESISTOR 1K£ CARBON FILM RESISTOR 10K£ 1/2W 1/4W 1/4W 1 2 9 R27 R14,32 R13,15,18-20,22, 36,39,49 R33,35,46 R34 R17 R31 R21 R26,28 R24,41,42,45 R29,38 R16,23,37,40,43 VR1 NR1 J2,3,7 J2,J8 LCD X1 S1 SW 1-8 EL1 IN 1 BZ1 L1-2 A0805041105 CARBON FILM RESISTOR 1M£ 1/4W 3 A0805041205 CARBON FILM RESISTOR 2M£ 1/4W 1 A0805041334 CARBON FILM RESISTOR 330K£ 1/4W 1 A0805041153 CARBON FILM RESISTOR 15K£ 1/4W 1 A0805041203 CARBON FILM RESISTOR 20K£ 1/4W 1 A0805041221 CARBON FILM RESISTOR 220£ 1/4W 2 A0805041223 CARBON FILM RESISTOR 22K£ 1/4W 4 A0805041471 CARBON FILM RESISTOR 470£ 1/4W 2 A0805041473 CARBON FILM RESISTOR 4.7K£ 1/4W 5 A0801001203 TRIM M ER 3006P-001-203 (20K ) 1 A0802047309 RESISTOR NETWORK 47K£ 9 PIN 1 A0902010020 C O N N E C T O R (POWER) 2 PIN W A FFER 3 A0910000080 C O N N E C T O R (FPC ) 8 PIN (ZIF) 2 A0910100130 SO C K E T STRIPS SIP 1*13 (FEMALE) 2 A1100260000 C R Y STA L 6.0M H Z 1 A1301000002 D IP SW . DS-02 (4 PIN) 1 A1306000003 T A C T SW . K PT-1104B 8 A1400000006 B A C K LIG H T 130*44m m 1 A1401005120 IN V E R T E R 5V TO 120V 1 A1500000004 B U ZZER OBO-15210 1 A5005000110 JUMPER 10m m 2 A0102000289 L.C.D. G289 1 A0201089511 I.C. 89C51 1 ============================================================================ 27 7. APPENDIX PARTS EXPLOSION: 28 ITEM PART NUMBER PART NAME SPECIFICATION 1 F0002PW0000 S/S PLATTER PW/PS SERIES 1 2 F0001PS1100 S/S HOUSING (UPPER) PS SERIES 1 3 G0004PW0100 RUBBER TUBE PW/PS SERIES 4 4 G0005BW1000 PLATTER BEARING RUBBER BW/PS SERIES 4 5 F0003PS110* LOAD CELL SUPPORT (UNDER) PS SERIES 6 A0071000*** LOAD CELL 7 F0003PS1100 LOAD CELL SUPPORT (UPPER) PS SERIES 1 8 F0009000035 S/S PLATE PILLAR SUPPORT 1 9 F0001PS1000 S/S HOUSING (UNDER) PS SERIES 1 10 A5001000312 MOVABLE BUSHING PS(AMB-1S) 11 QTY 1 1 NAME PLATE 1 2 12 F0029PS1000 S/S ADJUSTABLE FEET COVER PS ADJUSTABLE FEET 4 13 G0004BW1000 ADJUSTABLE FEET BW/PS SERIES 4 14 F0004PS1000 S/S PILLAR G0004PS1000 PLASTIC FOOT PS SERIES ¡ 8-10h 1 15 16 A5001000301 CABLE TIE CV-120S 1 17 F0003PS0000 S/S MOUNTING PLATE, U SHAPE INDICATOR FIXING 1 18 F0022000010 S/S ADJUSTABLE FEET INDICATOR FIXING 2 19 G0030PS1020 RUBBER PLUG PS SERIES 1 20 A0950000011 CABLE CONNECTOR (FEMALE) LTW-6FM 1 21 A0950000010 NUT LTW-6MS-C 1 22 A0906000210 RUBBER PLUG SCD-21 1 23 A0906000210 NUT SCD-21 2 24 F0005PS1100 S/S DISPLAY HOUSING (REAR) PS SERIES 1 25 A0950000010 CABLE CONNECTOR (MALE) 1 26 G0030PS1030 RUBBER PACKING LTW-6MS-C PS SERIES £ 21(£ 15.3)x5L 27 A0906000210 DC JACK SCD-21(BLACK) 1 28 A1208020351 BATTERY WIRE ARRAY 2 PIN,35cm 1 29 G0030FS0000 RUBBER RING SCD-21 1 30 A1600060400 RECHANGEABLE BATTERY GP4-6 6V,4Ah 1 31 F0013FS0000 S/S BATTERY PLATE FS/1705L/PS 1 32 G0030PS1010 RUBBER FRAME PS SERIES 1 33 E1PS1000011 P.C.B PS-10-X 1 34 A0102000289 L.C.D. UTN-G289JV 1 35 C1PS1000000 PC PLATE (8 HOLES) PS SERIES 1 36 G0030PS1000 RUBBER PACKING PS SERIES 6 37 F0005PS1000 S/S DISPLAY HOUSING (FRONT) PS SERIES 1 38 C1PS1XXXXX OVERLAY PANEL PC PS SERIES 1 39 Z0015100410 S/S SCREW M4*10 10 40 Z0014000625 S/S SCREW M6*25 4 41 Z0011000420 S/S SCREW M4*20 6 42 Z0014000508 SCREW M5*8 6 43 Z0015100406 S/S SCREW M4*6 6 44 Z0010000308 SCREW M3*8 2 45 Z0010001305 SCREW 3*5 5 46 Z0010000306 SCREW M3*5 6 1 1 29 30 31 32 33 34 35 36 37