Download 1. BEFORE INSTALLATION
Transcript
ENGLISH -*$+ Model names are indicated in 1-3. :KHQLQVWDOOLQJPXOWLXQLWVUHIHUWR WKHLQVWDOODWLRQPDQXDORIWKHPXOWL unit for outdoor unit installation. 63/,77<3($,5&21',7,21(56 INSTALLATION MANUAL Required Tools for Installation PPKH[DJRQDOZUHQFK 3KLOOLSVVFUHZGULYHU )ODUHWRROIRU5$ Level *DXJHPDQLIROGIRU5$ Scale 9DFXXPSXPSIRU5$ 8WLOLW\NQLIHRUVFLVVRUV &KDUJHKRVHIRU5$ PPKROHVDZ Torque wrench 3LSHFXWWHUZLWKUHDPHU :UHQFKRUVSDQQHU 1. BEFORE INSTALLATION 1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY • Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner. %HVXUHWRREVHUYHWKHZDUQLQJVDQGFDXWLRQVVSHFL¿HGKHUHDVWKH\LQFOXGHLPSRUWDQWLWHPVUHODWHGWRVDIHW\ $IWHUUHDGLQJWKLVPDQXDOEHVXUHWRNHHSLWWRJHWKHUZLWKWKH23(5$7,1*,16758&7,216IRUIXWXUHUHIHUHQFH WARNING N Do not install the unit by yourself (user). ,QFRPSOHWH LQVWDOODWLRQ FRXOG FDXVH ILUH RU HOHFWULF VKRFNLQMXU\GXHWRWKHXQLWIDOOLQJRUOHDNDJHRIZDWHU &RQVXOW WKH GHDOHU IURP ZKRP \RX SXUFKDVHG WKH XQLW RUDTXDOL¿HGLQVWDOOHU N Perform the installation securely referring to the installation manual. ,QFRPSOHWH LQVWDOODWLRQ FRXOG FDXVH ILUH RU HOHFWULF VKRFNLQMXU\GXHWRWKHXQLWIDOOLQJRUOHDNDJHRIZDWHU N Install the unit securely in a place which can bear the weight of the unit. If the installation location cannot bear the weight of the XQLWWKHXQLWFRXOGIDOOFDXVLQJLQMXU\ N (OHFWULFDOZRUNVKRXOGEHSHUIRUPHGE\DTXDOL¿HG H[SHULHQFHGHOHFWULFLDQDFFRUGLQJWRWKHLQVWDOODWLRQ manual. Be sure to use an exclusive circuit. Do not connect other electrical appliances to the circuit. ,IWKHFDSDFLW\RIWKHSRZHUFLUFXLWLVLQVXI¿FLHQWRUWKHUH LV LQFRPSOHWH HOHFWULFDO ZRUN LW FRXOG UHVXOW LQ D ¿UH RU DQHOHFWULFVKRFN N Do not damage the wires by applying excessive pressure with parts or screws. 'DPDJHGZLUHVFRXOGFDXVH¿UHRUHOHFWULFVKRFN N Be sure to cut off the main power in case of setting up the indoor P.C. board or wiring works. )DLOXUHWRGRVRFRXOGFDXVHHOHFWULFVKRFN N 8VHWKHVSHFL¿HGZLUHVWRFRQQHFWWKHLQGRRUDQG RXWGRRUXQLWVVHFXUHO\DQGDWWDFKWKHZLUHV¿UPO\WR the terminal block connecting sections so the stress of the wires is not applied to the sections. Do not H[WHQGWKHZLUHVRUXVHLQWHUPHGLDWHFRQQHFWLRQ ,QFRPSOHWHFRQQHFWLQJDQGVHFXULQJFRXOGFDXVH¿UH &RXOGOHDGWRGHDWKVHULRXVLQMXU\HWF N 'RQRWLQVWDOOWKHXQLWLQDSODFHZKHUHLQÀDPPDEOH gas may leak. ,I JDV OHDNV DQG DFFXPXODWHV LQ WKH DUHD DURXQG WKH XQLWLWFRXOGFDXVHDQH[SORVLRQ N Do not use intermediate connection of the power cord or the extension cord and do not connect many devices to one AC outlet. ,WFRXOGFDXVHD¿UHRUDQHOHFWULFVKRFNGXHWRGHIHFWLYHFRQWDFWGHIHFWLYHLQVXODWLRQH[FHHGLQJWKHSHUPLVVLEOHFXUUHQWHWF N %HVXUHWRXVHWKHSDUWVSURYLGHGRUVSHFL¿HGSDUWV for the installation work. 7KHXVHRIGHIHFWLYHSDUWVFRXOGFDXVHDQLQMXU\RUOHDNDJH RIZDWHUGXHWRD¿UHDQHOHFWULFVKRFNWKHXQLWIDOOLQJHWF N :KHQSOXJJLQJWKHSRZHUVXSSO\SOXJLQWRWKHRXWOHW PDNHVXUHWKDWWKHUHLVQRGXVWFORJJLQJRUORRVH parts in both the outlet and the plug. Make sure that the power supply plug is pushed completely into the outlet. ,IWKHUHLVGXVWFORJJLQJRUORRVHSDUWVRQWKHSRZHUVXSSO\SOXJRUWKHRXWOHWLWFRXOGFDXVHHOHFWULFVKRFNRU¿UH,I ORRVHSDUWVDUHIRXQGRQWKHSRZHUVXSSO\SOXJUHSODFHLW N Attach the electrical cover to the indoor unit and the service panel to the outdoor unit securely. If the electrical cover of the indoor unit and/or the service SDQHORIWKHRXWGRRUXQLWDUHQRWDWWDFKHGVHFXUHO\LWFRXOG UHVXOWLQD¿UHRUDQHOHFWULFVKRFNGXHWRGXVWZDWHUHWF N :KHQLQVWDOOLQJRUUHORFDWLQJWKHXQLWPDNHVXUH WKDWQRVXEVWDQFHRWKHUWKDQWKHVSHFL¿HGUHIULJHUant (R410A) enters the refrigerant circuit. $Q\ SUHVHQFH RI IRUHLJQ VXEVWDQFH VXFK DV DLU FDQ FDXVHDEQRUPDOSUHVVXUHULVHDQGPD\UHVXOWLQH[SORVLRQRULQMXU\ CAUTION N Earth the unit correctly. 'RQRWFRQQHFWWKHHDUWKWRDJDVSLSHZDWHUSLSHOLJKWning rod or telephone earth. Defective earthing could FDXVHHOHFWULFVKRFN N Install an earth leakage breaker depending on the installation place. ,I DQ HDUWK OHDNDJH EUHDNHU LV QRW LQVWDOOHG LW FRXOG FDXVHHOHFWULFVKRFN N Do not discharge the refrigerant into the atmosphere. If UHIULJHUDQWOHDNVGXULQJLQVWDOODWLRQYHQWLODWHWKHURRP ,I UHIULJHUDQW FRPHV LQ FRQWDFW ZLWK D ¿UH KDUPIXO JDV could be generated. N Check that the refrigerant gas does not leak after installation has been completed. ,IUHIULJHUDQWJDVOHDNVLQGRRUVDQGFRPHVLQWRFRQWDFW ZLWKWKHÀDPHRIDIDQKHDWHUVSDFHKHDWHUVWRYHHWF KDUPIXOVXEVWDQFHVZLOOEHJHQHUDWHG N Use appropriate tools and piping materials for installation. 7KH SUHVVXUH RI 5$ LV WLPHV PRUH WKDQ 5 1RWXVLQJDSSURSULDWHWRROVRUPDWHULDOVDQGLQFRPSOHWH LQVWDOODWLRQFRXOGFDXVHWKHSLSHVWREXUVWRULQMXU\ N :KHQSXPSLQJGRZQWKHUHIULJHUDQWVWRSWKHFRPpressor before disconnecting the refrigerant pipes. ,I WKH UHIULJHUDQW SLSHV DUH GLVFRQQHFWHG ZKLOH WKH FRPSUHVVRULVUXQQLQJDQGWKHVWRSYDOYHLVRSHQDLUFRXOGEHGUDZQ LQ DQG WKH SUHVVXUH LQ WKH UHIULJHUDWLRQ F\FOH FRXOG EHFRPH DEQRUPDOO\KLJK7KLVFRXOGFDXVHWKHSLSHVWREXUVWRULQMXU\ N :KHQLQVWDOOLQJWKHXQLWVHFXUHO\FRQQHFWWKHUHfrigerant pipes before starting the compressor. ,IWKHFRPSUHVVRULVVWDUWHGEHIRUHWKHUHIULJHUDQWSLSHV DUH FRQQHFWHG DQG ZKHQ WKH VWRS YDOYH LV RSHQ DLU could be drawn in and the pressure in the refrigeration F\FOHFRXOGEHFRPHDEQRUPDOO\KLJK7KLVFRXOGFDXVH WKHSLSHVWREXUVWRULQMXU\ N )DVWHQDÀDUHQXWZLWKDWRUTXHZUHQFKDVVSHFL¿HG in this manual. ,IIDVWHQHGWRRWLJKWDÀDUHQXWPD\EUHDNDIWHUDORQJ SHULRGDQGFDXVHUHIULJHUDQWOHDNDJH N The unit shall be installed in accordance with national wiring regulations. &RXOGOHDGWRVHULRXVLQMXU\LQSDUWLFXODUHQYLURQPHQWVZKHQRSHUDWHGLQFRUUHFWO\ N Perform the drainage/piping work securely accord- N Do not install the outdoor unit where small animals ing to the installation manual. may live. ,I WKHUH LV GHIHFW LQ WKH GUDLQDJHSLSLQJ ZRUN ZDWHU ,IVPDOODQLPDOVHQWHUDQGWRXFKWKHHOHFWULFSDUWVLQVLGH FRXOGGURSIURPWKHXQLWVRDNLQJDQGGDPDJLQJKRXVHWKHXQLWLWFRXOGFDXVHDPDOIXQFWLRQVPRNHHPLVVLRQ hold goods. RU ¿UH $OVR DGYLVH XVHU WR NHHS WKH DUHD DURXQG WKH unit clean. N 'RQRWWRXFKWKHDLULQOHWRUWKHDOXPLQXP¿QVRI the outdoor unit. 7KLVFRXOGFDXVHLQMXU\ 1-2. SELECTING THE INSTALLATION LOCATION INDOOR UNIT :KHUHDLUÀRZLVQRWEORFNHG :KHUHFRRODLUVSUHDGVRYHUWKHHQWLUHURRP • Rigid wall without vibration. :KHUHLWLVQRWH[SRVHGWRGLUHFWVXQVKLQH :KHUHHDVLO\GUDLQHG $WDGLVWDQFHPRUPRUHDZD\IURP\RXU79DQGUDGLR 2SHUDWLRQRIWKHDLUFRQGLWLRQHUPD\LQWHUIHUHZLWKUDGLR RU79UHFHSWLRQ$QDPSOL¿HUPD\EHUHTXLUHGIRUWKHDIfected device. ,QDSODFHDVIDUDZD\DVSRVVLEOHIURPÀXRUHVFHQWDQG LQFDQGHVFHQW OLJKWV VR WKH LQIUDUHG UHPRWH FRQWURO FDQ RSHUDWHWKHDLUFRQGLWLRQHUQRUPDOO\ :KHUHWKHDLU¿OWHUFDQEHUHPRYHGDQGUHSODFHGHDVLO\ REMOTE CONTROLLER :KHUHLWLVHDV\WRRSHUDWHDQGHDVLO\YLVLEOH • Where children cannot touch it. 6HOHFWDSRVLWLRQDERXWPDERYHWKHÀRRUDQGFKHFN WKDW VLJQDOV IURP WKH UHPRWH FRQWUROOHU DUH VXUHO\ UHFHLYHG E\ WKH LQGRRU XQLW IURP WKDW SRVLWLRQ µEHHS¶ RU µEHHSEHHS¶UHFHLYLQJWRQHVRXQGV$IWHUWKDWDWWDFKUHPRWHFRQWUROOHUKROGHUWRDSLOODURUZDOODQGLQVWDOOZLUHOHVVUHPRWHFRQWUROOHU Note: ,QURRPVZKHUHLQYHUWHUW\SHÀXRUHVFHQWODPSVDUHXVHG WKHVLJQDOIURPWKHZLUHOHVVUHPRWHFRQWUROOHUPD\QRWEH received. OUTDOOR UNIT :KHUHLWLVQRWH[SRVHGWRVWURQJZLQG :KHUHDLUÀRZLVJRRGDQGGXVWOHVV :KHUHUDLQRUGLUHFWVXQOLJKWFDQEHDYRLGHGDVPXFKDV possible. :KHUH QHLJKERXUV DUH QRW DQQR\HG E\ RSHUDWLRQ VRXQG or hot air. • Where rigid wall or support is available to prevent the increase of operation sound or vibration. :KHUHWKHUHLVQRULVNRIFRPEXVWLEOHJDVOHDNDJH :KHQLQVWDOOLQJWKHXQLWDWDKLJKOHYHOEHVXUHWRVHFXUH the unit legs. :KHUHLWLVDWOHDVWPDZD\IURPWKHDQWHQQDRI79VHW RUUDGLR2SHUDWLRQRIWKHDLUFRQGLWLRQHUPD\LQWHUIHUHZLWK UDGLR RU 79 UHFHSWLRQ LQ DUHDV ZKHUH UHFHSWLRQ LV ZHDN $QDPSOL¿HUPD\EHUHTXLUHGIRUWKHDIIHFWHGGHYLFH ,QVWDOOWKHXQLWKRUL]RQWDOO\ 3OHDVH LQVWDOO LW LQ DQ DUHD QRW DIIHFWHG E\ VQRZIDOO RU EORZLQJVQRZ,QDUHDVZLWKKHDY\VQRZSOHDVHLQVWDOOD FDQRS\DSHGHVWDODQGRUVRPHEDIÀHERDUGV Note: ,WLVDGYLVDEOHWRPDNHDSLSLQJORRSQHDURXWGRRUXQLWVRDV WRUHGXFHYLEUDWLRQWUDQVPLWWHGIURPWKHUH Note: :KHQRSHUDWLQJWKHDLUFRQGLWLRQHULQORZRXWVLGHWHPSHUDWXUHEHVXUHWRIROORZWKHLQVWUXFWLRQVGHVFULEHGEHORZ • Never install the outdoor unit in a place where its air LQOHWRXWOHWVLGHPD\EHH[SRVHGGLUHFWO\WRZLQG 7R SUHYHQW H[SRVXUH WR ZLQG LQVWDOO WKH RXWGRRU XQLW with its air inlet side facing the wall. • 7RSUHYHQWH[SRVXUHWRZLQGLWLVUHFRPPHQGHGWRLQVWDOO DEDIÀHERDUGRQWKHDLURXWOHWVLGHRIWKHRXWGRRUXQLW Avoid the following places for installation where air conditioner trouble is liable to occur. :KHUHÀDPPDEOHJDVFRXOGOHDN :KHUHWKHUHLVPXFKPDFKLQHRLO 6DOW\SODFHVVXFKDVWKHVHDVLGH :KHUHVXO¿GHJDVLVJHQHUDWHGVXFKDVDKRWVSULQJ :KHUHWKHUHLVKLJKIUHTXHQF\RUZLUHOHVVHTXLSPHQW 1-3. SPECIFICATIONS 0RGHO Indoor unit 3RZHUVXSSO\ Outdoor unit 06=*(9$ 06=*(9$ 06=*(9$ 08=*(9$ 08=*(9$ 06=*(9$ 08=*(9$ Rated Voltage )UHTXHQF\ 9 +] &RQQHFW WR WKH SRZHU VZLWFK ZKLFK KDV D JDS RI PP RU PRUHZKHQRSHQWRLQWHUUXSWWKHVRXUFHSRZHUSKDVH:KHQ WKHSRZHUVZLWFKLVVKXWRIILWPXVWLQWHUUXSWDOOSKDVHV 8VHZLUHVLQFRQIRUPLW\ZLWKGHVLJQ,(& 1HYHU XVH SLSHV ZLWK WKLFNQHVV OHVV WKDQ VSHFLILHG 7KH SUHVVXUHUHVLVWDQFHZLOOEHLQVXI¿FLHQW :LUHVSHFL¿FDWLRQV %UHDNHU FDSDFLW\ 3RZHUVXSSO\ $ 3-core PP $ 3-core PP Indoor/outdoor connecting wire FRUH PP 3LSHVL]H WKLFNQHVV Gas / Liquid ¡PP PP ¡PP PP *(*( 3LSHOHQJWKDQGKHLJKWGLIIHUHQFH 0D[SLSHOHQJWK P 0D[KHLJKWGLIIHUHQFH P 0D[QXPEHURIEHQGV 5HIULJHUDQWDGMXVWPHQW$ JP ,QVXODWLRQWKLFNQHVV PP 8VHDFRSSHUSLSHRUDFRSSHUDOOR\VHDPOHVVSLSH $GGLWLRQDOUHIULJHUDQW $îSLSHOHQJWKP %HFDUHIXOQRWWRFUXVKRUEHQGWKHSLSHGXULQJSLSHEHQGLQJ ,QVXODWLRQ PDWHULDO +HDW UHVLVWLQJ IRDP SODVWLF VSHFL¿FJUDYLW\ 5HIULJHUDQWSLSHEHQGLQJUDGLXVPXVWEHPPRUPRUH ,I SLSH OHQJWK H[FHHGV P DGGLWLRQDO UHIULJHUDQW 5$ %HVXUHWRXVHWKHLQVXODWLRQRIVSHFL¿HGWKLFNQHVV([FHVVLYHWKLFNQHVVPD\FDXVHLQFRUUHFWLQVWDOODWLRQRIWKHLQGRRU FKDUJH LV UHTXLUHG 1R DGGLWLRQDO FKDUJH LV UHTXLUHG IRU XQLWDQGLQVXI¿FLHQWWKLFNQHVVPD\FDXVHGHZGULSSDJH SLSHOHQJWKOHVVWKDQP 5HPRWHFRQWUROOHUKROGHU )L[LQJVFUHZIRUîPP %ODFN %DWWHU\$$$IRU :LUHOHVVUHPRWHFRQWUROOHU Felt tape )RUOHIWRUOHIWUHDUSLSLQJ P RUPR P UH $LUFOHDQLQJ¿OWHU When the piping is to be attached to a wall containing PHWDOVWLQSODWHGRUPHWDO QHWWLQJXVHDFKHPLFDOO\ WUHDWHGZRRGHQSLHFH PPRUWKLFNHUEHWZHHQWKH wall and the piping or wrap WRWXUQVRILQVXODWLRQYLQ\OWDSHDURXQGWKHSLSLQJ 7RXVHH[LVWLQJSLSLQJSHUIRUP&22/RSHUDWLRQIRU PLQXWHVDQGSXPSGRZQ EHIRUHUHPRYLQJWKHROGDLU FRQGLWLRQHU5HPDNHÀDUH DFFRUGLQJWRWKHGLPHQVLRQ for new refrigerant. PPRUPRUH <Outdoor unit> 'UDLQVRFNHW9$W\SHRQO\ 'UDLQFDS¡*(9$RQO\ PARTS TO BE PROVIDED AT YOUR SITE $ % & ' ( ) * + Indoor/outdoor unit connecting wire* ([WHQVLRQSLSH Wall hole sleeve Wall hole cover 3LSH¿[LQJEDQG WR )L[LQJVFUHZIRU(îPP WR 3LSLQJWDSH 3XWW\ Drain hose , RUVRIW39&KRVHPPLQQHU GLDPHWHURUKDUG39&SLSH93 *(9$ *(*( PPRUPRUH PP PRUH RU RU GE50VA RUPPP RUH - Refrigeration oil . 3RZHUVXSSO\FRUG * Note: 3ODFHLQGRRURXWGRRUXQLWFRQQHFWLQJZLUH$ DQGSRZHUVXSSO\FRUG.DWOHDVWPDZD\ IURPWKH79DQWHQQDZLUH 8QLWVVKRXOGEHLQVWDOOHGE\OLFHQVHGFRQWUDFWRU DFFRUGLQJWRORFDOFRGHUHTXLUHPHQWV $IWHUWKHOHDNWHVWDSSO\ LQVXODWLQJPDWHULDOWLJKWO\ so that there is no gap. *(*( PPRUPRUH , , )L[WKHSLSHWRZDOO ZLWKSLSH¿[LQJ EDQG( &XWRIIWKH H[WUDOHQJWK 3LSH¿[LQJEDQG ( )L[LQJVFUHZ ) Outdoor unit installation*(*( PP PP PP Air inlet PP ,QVWDOODWLRQSODWH¿[LQJVFUHZ îPP P P RUPR UH Seal the wall hole JDSZLWKSXWW\+ PP :DOOKROHFRYHU' Be sure to use wall hole Indoor unit VOHHYH&WRSUHYHQW indoor/outdoor connecting ZLUH$IURPFRQWDFWLQJ Wall hole PHWDOSDUWVLQWKHZDOODQG VOHHYH& WRSUHYHQWGDPDJHE\ rodents in case the wall is hollow. PP Installation plate PPRUPRUH PPRUPRUHIRU OHIWDQGOHIWEDFNSLSLQJ XVLQJVSDFHU 1-4. INSTALLATION DIAGRAM ACCESSORIES &KHFNWKHIROORZLQJSDUWVEHIRUHLQVWDOODWLRQ <Indoor unit> Air outlet PPîPPVORW PP Drain piping for outdoor unit <VA type only> 3URYLGHGUDLQSLSLQJEHIRUHLQGRRUDQG outdoor piping connection. &RQQHFW GUDLQ KRVH , ,' PP DV shown in the illustration. &KRRVH RQH KROH IRU GUDLQLQJ DQG LQVWDOO GUDLQ VRFNHW &ORVH WKH UHPDLQLQJWZRKROHVZLWKGUDLQFDS *(9$RQO\ 0DNHVXUHWRSURYLGHGUDLQSLSLQJZLWK DGRZQKLOOJUDGHIRUHDV\GUDLQÀRZ Note: ,QVWDOOWKHXQLWKRUL]RQWDOO\ 'RQRWXVHGUDLQVRFNHWLQFROG UHJLRQV'UDLQPD\IUHH]HDQGPDNHWKH fan stop. IMPORTANT NOTES 7RFRPSO\ZLWKWKHUHTXLUHPHQWVRI$XVWUDOLDQVWDQGDUG$61=6HOHFWULFDOLQVWDOODWLRQVZLULQJUXOHVWKHHOHFWULFDOZLULQJUHTXLUHGEHWZHHQWKH LQGRRUDQGRXWGRRUXQLWVPXVWEHLQVWDOOHGE\DOLFHQFHGHOHFWULFDOFRQWUDFWRU PP RUP RUH $SSHDUDQFHRIWKHRXWGRRUXQLWPD\GLIIHUIURP VRPHPRGHOV 2. INDOOR UNIT INSTALLATION 2-1. FIXING OF INSTALLATION PLATE )LQGDVWUXFWXUDOPDWHULDOVXFKDVDVWXGLQWKHZDOODQG¿[LQVWDOODWLRQSODWHKRUL]RQWDOO\ZLWK¿[LQJVFUHZV 7R SUHYHQW LQVWDOODWLRQ SODWH IURP YLEUDWLQJ EH VXUH WR LQVWDOO WKH ¿[LQJ VFUHZV LQ WKH KROHV LQGLFDWHG LQ WKH LOOXVWUDWLRQ )RU DGGHG VXSSRUW ¿[LQJ VFUHZV PD\ DOVR EH installed in other holes. :KHQ WKH NQRFNRXW LV UHPRYHG DSSO\ YLQ\O WDSH WR WKH NQRFNRXW HGJHV WR SUHYHQW GDPDJLQJWKHZLUHV :KHQEROWVUHFHVVHGLQWKHFRQFUHWHZDOODUHWREHXWLOL]HGVHFXUHLQVWDOODWLRQSODWH XVLQJîÂîRYDOKROHPPSLWFK ,IWKHUHFHVVHGEROWLVWRRORQJFKDQJHLWIRUDVKRUWHURQHDYDLODEOHLQWKHPDUNHW Wall 2-2. WALL HOLE DRILLING &HLOLQJ Bind the line to the center hole. 7HUPLQDOEORFN 9$FODPS 'HWHUPLQHWKHZDOOKROHSRVLWLRQ 'ULOO D ¡ PP KROH 7KH RXWGRRU VLGH VKRXOG EH ¡PP WRPPORZHUWKDQWKHLQGRRUVLGH ,QVHUWZDOOKROHVOHHYH& ,QVWDOODWLRQSODWH /RRVHQWHUPLQDOVFUHZDQGFRQQHFW¿UVWWKHHDUWKZLUHWKHQLQGRRURXWGRRUXQLWFRQQHFWLQJZLUH$WRWKHWHUPLQDOEORFN%HFDUHIXOQRWWRPDNHPLVZLULQJ)L[WKHZLUH WRWKHWHUPLQDOEORFNVHFXUHO\VRWKDWQRSDUWRILWVFRUHLVDSSHDUHGDQGQRH[WHUQDO IRUFHLVFRQYH\HGWRWKHFRQQHFWLQJVHFWLRQRIWKHWHUPLQDOEORFN )LUPO\WLJKWHQWKHWHUPLQDOVFUHZVWRSUHYHQWWKHPIURPORRVHQLQJ$IWHUWLJKWHQLQJSXOO WKHZLUHVOLJKWO\WRFRQ¿UPWKDWWKH\GRQRWPRYH 6HFXUHLQGRRURXWGRRUXQLWFRQQHFWLQJZLUH$DQGWKHHDUWKZLUHZLWKWKH9$FODPS 1HYHUIDLOWRKRRNWKHOHIWFODZRIWKH9$FODPS$WWDFKWKH9$FODPSVHFXUHO\ )L[LQJVFUHZ PP Outdoor side PP PP PPRUPRUH PPRUPRUHIRUOHIWDQGOHIW EDFNSLSLQJXVLQJVSDFHU Lead wire Level Indoor/outdoor unit FRQQHFWLQJZLUH$ PP RUPRUH PP RUPRUH PP Wall )L[LQJVFUHZ $OLJQWKHSOXPE line with the PDUN . Insert the scale. * Wall &HQWHURI ¡PPKROH Align the scale with the line. * ,QGRRUWHUPLQDOEORFN )RU IXWXUH VHUYLFLQJ JLYH H[WUD OHQJWK WR WKH connecting wires. Earth wire 0DNHHDUWKZLUHDOLWWOHORQJHUWKDQRWKHUV0RUH JUHHQ\HOORZ WKDQPP 'RQRWIROGWKHH[FHVVZLUHRUFUDPLWLQWRVPDOO VSDFH7DNHFDXWLRQQRWWRGDPDJHWKHZLUHV Indoor/outdoor Note: Do not place the wires between the inunit GRRUXQLWDQGWKHLQVWDOODWLRQSODWH'DPDJHG connecting wire $ ZLUHFRXOGFDXVHKHDWJHQHUDWLRQRU¿UH 3OXPE 6DPHIRUOHIWKROH 2XWGRRUWHUPLQDOEORFN 2-3. CONNECTING WIRES FOR INDOOR UNIT <RXFDQFRQQHFWLQGRRURXWGRRUOHDGZLUHZLWKRXWUHPRYLQJWKHIURQWSDQHO 2SHQWKHIURQWSDQHO 5HPRYH9$FODPS 3DVVLQGRRURXWGRRUXQLWFRQQHFWLQJZLUH$IURPWKHEDFNRIWKHLQGRRUXQLWDQGSURFess the end of the wire. 2-4. PIPE FORMING AND DRAIN PIPING Pipe Forming 3ODFHWKHGUDLQKRVHEHORZWKHUHIULJHUDQWSLSLQJ 0DNHVXUHWKDWWKHGUDLQKRVHLVQRWKHDYHGRUVQDNHG 'RQRWSXOOWKHKRVHZKHQDSSO\LQJWKHWDSH :KHQ WKH GUDLQ KRVH SDVVHV WKH URRP EH VXUH WR ZUDS LQVXODWLRQPDWHULDOREWDLQDEOHDWDVWRUHDURXQGLW Liquid pipe Gas pipe Indoor/outdoor unit FRQQHFWLQJZLUH$ )HOWWDSH 3LSLQJWDSH* 5HDUULJKWRUGRZQZDUGSLSLQJ &XWRIILQFDVHRI 3XW WKH UHIULJHUDQW SLSLQJ DQG WKH GUDLQ KRVH right piping. WRJHWKHU WKHQ ILUPO\ DSSO\ SLSLQJ WDSH * IURPWKHHQG &XWRIILQFDVHRI ,QVHUW WKH SLSLQJ DQG WKH GUDLQ KRVH LQWR WKH downward piping. ZDOOKROHVOHHYH&DQGKRRNWKHXSSHUSDUW RIWKHLQGRRUXQLWRQWKHLQVWDOODWLRQSODWH &KHFNLIWKHLQGRRUXQLWLVKRRNHGVHFXUHO\RQWKHLQVWDOODWLRQSODWHE\PRYLQJ the unit to left and right. 7KUXVWWKHORZHUSDUWRIWKHLQGRRUXQLWLQWRWKHLQVWDOODWLRQSODWH Drain Piping ,IWKHH[WHQVLRQGUDLQKRVHKDVWRSDVVWKURXJKDURRPEHVXUHWRZUDSLWZLWKFRPPHUFLDOO\VROGLQVXODWLRQ 7KHGUDLQKRVHVKRXOGSRLQWGRZQZDUGIRUHDV\GUDLQÀRZ)LJ ,IWKHGUDLQKRVHSURYLGHGZLWKWKHLQGRRUXQLWLVWRRVKRUWFRQQHFWLWZLWKGUDLQKRVH, WKDWVKRXOGEHSURYLGHGDW\RXUVLWH)LJ :KHQFRQQHFWLQJWKHGUDLQKRVHWRWKHKDUGYLQ\OFKORULGHSLSHEHVXUHWRLQVHUWLW VHFXUHO\LQWRWKHSLSH)LJ Drain hose Drain hose Downward slope +DUGYLQ\OFKORULGH SLSH,'PP FPRU PRUH Soft hose ,'PP Insert VHFXUHO\ Different GLDPHWHUMRLQW )LJ )LJ Fig. 3 'RQRWPDNHGUDLQSLSLQJDVVKRZQEHORZ $FFXPXODWHG drain water Do not raise Tip of drain hose dipped in water Air Water OHDNDJH Water OHDNDJH Waving Water OHDNDJH At least PP gap Ditch Left or left-rear piping Note: Be sure to reattach the drain hose and the drain cap in case of left or left-rear piping. 2WKHUZLVHLWFRXOGFDXVHGURSV RIZDWHUWRGULSGRZQIURPWKH drain hose. &XWRIILQFDVHRIOHIW piping. 3LSLQJWDSH* )HOWWDSH Drain cap Drain cap 3XWWKHUHIULJHUDQWSLSLQJDQGWKHGUDLQKRVHWRJHWKHU WKHQ¿UPO\DSSO\IHOWWDSHIURPWKHHQG )HOW WDSH RYHUODS ZLGWK VKRXOG EH WKH WDSH ZLGWK8VHDEDQGDJHVWRSSHUDWWKHHQGRIIHOWWDSH 3XOORXWWKHGUDLQFDSDWWKHUHDUULJKWRIWKHLQGRRUXQLW )LJ )LJ +ROGWKHFRQYH[VHFWLRQDWWKHHQGDQGSXOOWKH drain cap. 3XOORXWWKHGUDLQKRVHDWWKHUHDUOHIWRIWKHLQGRRUXQLW )LJ Drain hose +ROGWKHFODZPDUNHGE\WKHDUURZVDQGSXOORXWWKH )LJ drain hose forward. 3XW WKH GUDLQ FDS LQWR WKH VHFWLRQ WR ZKLFK WKH GUDLQ hose is to be attached at the rear of the indoor unit. )LJ • Insert not sharp-edged tools such as screwdrivers Drain cap into the hole at the end of the cap and insert the cap IXOO\LQWRWKHGUDLQSDQ Fig. 3 ,QVHUWWKHGUDLQKRVHIXOO\LQWRWKHGUDLQSDQDWWKHUHDU Drain hose ULJKWRIWKHLQGRRUXQLW)LJ &KHFNLIWKHKRVHLVKRRNHGVHFXUHO\WRWKHSURMHFtion of its inserting part at the drain pan. )LJ ,QVHUW WKH GUDLQ KRVH LQWR ZDOO KROH VOHHYH & DQG KRRNWKHXSSHUSDUWRILQGRRUXQLWRQLQVWDOODWLRQSODWH 7KHQPRYHWKHLQGRRUXQLWFRPSOHWHO\WRWKHOHIWLQ RUGHUWRPDNHSODFLQJWKHSLSLQJLQWKHEDFNVSDFHRI the unit easier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¿UPWKDWWKH\GRQRWPRYH &RQQHFWSRZHUVXSSO\FRUG. )L[LQGRRURXWGRRUXQLWFRQQHFWLQJZLUH$DQGSRZHUVXSSO\FRUG.ZLWKWKHFRUG FODPS &ORVHWKHVHUYLFHSDQHOVHFXUHO\ 7HUPLQDOEORFN PP PP 0DNH HDUWK ZLUH D OLWWOH ORQJHU WKDQRWKHUV0RUHWKDQPP )RU IXWXUH VHUYLFLQJ JLYH H[WUD length to the connecting wires. ,QGRRURXWGRRUXQLWFRQQHFWLQJZLUH$ 3RZHUVXSSO\FRUG. 3RZHUVXSSO\ FRUG. &RUGFODPS *(! &RUGFODPS *(! Lead wire 3-2. FLARING WORK &XW WKH FRSSHU SLSH FRUUHFWO\ ZLWK SLSH FXWWHU &RSSHU )LJ pipe &RPSOHWHO\UHPRYHDOOEXUUVIURPWKHFXWFURVVVHFWLRQRISLSH)LJ )LJ 3XWWKHHQGRIWKHFRSSHUSLSHWRGRZQZDUGGLUHFWLRQDV\RXUHPRYHEXUUVLQRUGHUWRDYRLGWROHW burrs drop in the piping. No good Good 5HPRYH IODUH QXWV DWWDFKHG WR LQGRRU DQG RXWGRRU XQLWV WKHQ SXW WKHP RQ SLSH KDYLQJ FRPSOHWHG EXUU UHPRYDO 1RW SRVVLEOH WR SXW WKHP RQ DIWHU IODULQJ ZRUN )ODULQJ ZRUN )LJ )LUPO\ KROG FRSSHU SLSH LQ Tilted Uneven Burred WKHGLPHQVLRQVKRZQLQWKHWDEOH6HOHFW$PPIURP )LJ WKHWDEOHDFFRUGLQJWRWKHWRRO\RXXVH &KHFN &RPSDUHWKHÀDUHGZRUNZLWK)LJ ,IÀDUHLVQRWHGWREHGHIHFWLYHFXWRIIWKHÀDUHGVHFWLRQDQGGRÀDULQJZRUN again. Flaring tool Burr &RSSHUSLSH 6SDUHUHDPHU 3LSHFXWWHU &OXWFKW\SH Fig. 3 :LQJQXWW\SH )LJ 6PRRWKDOO around Die Flare nut 3LSHGLDPHWHU PP ¡´ ¡´ ¡´ ¡´ Inside is shinLQJZLWKRXWDQ\ scratches. &RSSHUSLSH )LJ Even length all around )LJ $PP Tightening torque Nut &OXWFKW\SH &OXWFKW\SH Wing nut PP tool tool W\SHWRRO 1P NJIFP IRU5$ IRU5 IRU5 WR WR WR WR WR WR WR WR WR WR WR WR 3-3. PIPE CONNECTION )DVWHQÀDUHQXWZLWKDWRUTXHZUHQFKDVVSHFL¿HGLQWKHWDEOH :KHQ IDVWHQHG WRR WLJKW ÀDUH QXW PD\ EUDNH DIWHU D ORQJ SHULRG DQG FDXVH UHIULJHUDQW OHDNDJH Indoor unit connection &RQQHFWERWKOLTXLGDQGJDVSLSLQJVWRLQGRRUXQLW $SSO\DWKLQFRDWRIUHIULJHUDWLRQRLO-RQWKHVHDWVXUIDFHRISLSH )RUFRQQHFWLRQ¿UVWDOLJQWKHFHQWHUWKHQWLJKWHQWKH¿UVWWRWXUQVRIÀDUHQXW 8VHWLJKWHQLQJWRUTXHWDEOHEHORZDVDJXLGHOLQHIRULQGRRUXQLWVLGHXQLRQMRLQWVHFWLRQ DQGWLJKWHQXVLQJWZRZUHQFKHV([FHVVLYHWLJKWHQLQJGDPDJHVWKHÀDUHVHFWLRQ Outdoor unit connection &RQQHFWSLSHVWRVWRSYDOYHSLSHMRLQWRIWKHRXWGRRUXQLWLQWKH VDPHPDQQHUDSSOLHGIRULQGRRUXQLW )RUWLJKWHQLQJXVHDWRUTXHZUHQFKRUVSDQQHUDQGXVHWKH VDPHWLJKWHQLQJWRUTXHDSSOLHGIRULQGRRUXQLW WARNING :KHQLQVWDOOLQJWKHXQLWVHFXUHO\FRQQHFWWKHUHIULJHUDQW pipes before starting the compressor. 3-4. INSULATION AND TAPING &RYHUSLSLQJMRLQWVZLWKSLSHFRYHU )RURXWGRRUXQLWVLGHVXUHO\LQVXODWHHYHU\SLSLQJLQFOXGLQJYDOYHV 8VLQJSLSLQJWDSH*DSSO\WDSLQJVWDUWLQJIURPWKHHQWU\RIRXWGRRUXQLW 6WRSWKHHQGRISLSLQJWDSH*ZLWKWDSHZLWKDGKHVLYHDJHQWDWWDFKHG :KHQSLSLQJKDYHWREHDUUDQJHGWKURXJKDERYHFHLOLQJFORVHWRUZKHUHWKHWHPSHUDWXUHDQGKXPLGLW\DUHKLJKZLQGDGGLWLRQDOFRPPHUFLDOO\VROGLQVXODWLRQWRSUHYHQW condensation. 385*,1*352&('85(6/($.7(67$1'7(67581 4-1. PURGING PROCEDURES AND LEAK TEST 4-2. TEST RUN 5HPRYHVHUYLFHSRUWFDSRIVWRSYDOYHRQWKHVLGHRIWKHRXWGRRUXQLWJDVSLSH7KH VWRSYDOYHZLOOQRWZRUNLQLWVLQLWLDOVWDWHIUHVKRXWRIWKHIDFWRU\WRWDOO\FORVHGZLWKFDS RQ &RQQHFWJDXJHPDQLIROGYDOYHDQGYDFXXPSXPSWRVHUYLFHSRUWRIVWRSYDOYHRQWKH gas pipe side of the outdoor unit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details. WRWXUQV &ORVH *Open +H[DJRQDOZUHQFK &RPSRXQGSUHVVXUHJDXJH –03D IRU5$ Stop valve cap –PP+J 7RUTXHWR 3UHVVXUHJDXJH 1P Stop valve IRU5$ WRNJIƒFP for LIQUID *DXJHPDQLIROGYDOYH IRU5$ Handle Low Handle High &KDUJHKRVH IRU5$ Stop valve for GAS Service port cap 7RUTXHWR 1PWR NJI•FP Adapter for preYHQWLQJWKHEDFN ÀRZ 9DFXXPSXPSRUWKHYDFXXP SXPSZLWKWKHIXQFWLRQWR SUHYHQWWKHEDFNÀRZ 3UHFDXWLRQVZKHQXVLQJWKHFRQWUROYDOYH When attaching the control valve WRWKHVHUYLFHSRUWYDOYHFRUHPD\ GHIRUPRUORRVHQLIH[FHVVSUHVVXUH LVDSSOLHG7KLVPD\FDXVHJDVOHDN Service port A &RQWUROYDOYH Open &KDUJHKRVH &ORVH %RG\ When attaching the control valve to WKHVHUYLFHSRUWPDNHVXUHWKDWWKH YDOYHFRUHLVLQFORVHGSRVLWLRQDQG then tighten part A. Do not tighten SDUW$RUWXUQWKHERG\ZKHQYDOYH core is in open position. 5XQWKHYDFXXPSXPS9DFXXPL]HIRUPRUHWKDQPLQXWHV &KHFN WKH YDFXXP ZLWK JDXJH PDQLIROG YDOYH WKHQ FORVH JDXJH PDQLIROG YDOYH DQG VWRSWKHYDFXXPSXPS /HDYHDVLWLVIRURQHRUWZRPLQXWHV0DNHVXUHSRLQWHUJDXJHPDQLIROGYDOYHUHPDLQV LQWKHVDPHSRVLWLRQ&RQ¿UPWKDWSUHVVXUHJDXJHVKRZV±03D>*DXJH@± PP+J 5HPRYHJDXJHPDQLIROGYDOYHTXLFNO\IURPVHUYLFHSRUWRIVWRSYDOYH $IWHUUHIULJHUDQWSLSHVDUHFRQQHFWHGDQGHYDFXDWHGIXOO\RSHQDOOVWRSYDOYHVRQERWK VLGHVRIJDVSLSHDQGOLTXLGSLSH2SHUDWLQJZLWKRXWIXOO\RSHQLQJORZHUVWKHSHUIRUPance and this causes trouble. 5HIHU WR DQG FKDUJH WKH SUHVFULEHG DPRXQW RI UHIULJHUDQW LI QHHGHG %H VXUH WR FKDUJH VORZO\ ZLWK OLTXLG UHIULJHUDQW 2WKHUZLVH FRPSRVLWLRQ RI WKH UHIULJHUDQW LQ WKH V\VWHPPD\EHFKDQJHGDQGDIIHFWSHUIRUPDQFHRIWKHDLUFRQGLWLRQHU 7LJKWHQFDSRIVHUYLFHSRUWWRREWDLQWKHLQLWLDOVWDWXV /HDNWHVW (PHUJHQF\ operation switch (26: Checking the remote (infrared) signal reception 3UHVVWKH212))EXWWRQRQWKHUHPRWHFRQWUROOHUDQGFKHFNWKDWDQHOHFWURQLFVRXQG LVKHDUGIURPWKHLQGRRUXQLW3UHVVWKH212))EXWWRQDJDLQWRWXUQWKHDLUFRQGLWLRQHU off. 2QFHWKHFRPSUHVVRUVWRSVWKHUHVWDUWSUHYHQWLYHGHYLFHRSHUDWHVVRWKHFRPSUHVVRU ZLOOQRWRSHUDWHIRUPLQXWHVWRSURWHFWWKHDLUFRQGLWLRQHU 4-3. AUTO RESTART FUNCTION 7KLVSURGXFWLVHTXLSSHGZLWKDQDXWRUHVWDUWIXQFWLRQ:KHQWKHSRZHUVXSSO\LVVWRSSHG GXULQJRSHUDWLRQVXFKDVGXULQJEODFNRXWVWKHIXQFWLRQDXWRPDWLFDOO\VWDUWVRSHUDWLRQLQ WKHSUHYLRXVVHWWLQJRQFHWKHSRZHUVXSSO\LVUHVXPHG5HIHUWRWKHRSHUDWLQJLQVWUXFWLRQVIRUGHWDLOV Caution: $IWHUWHVWUXQRUUHPRWHVLJQDOUHFHSWLRQFKHFNWXUQRIIWKHXQLWZLWKWKH(26:RU WKHUHPRWHFRQWUROOHUEHIRUHWXUQLQJRIIWKHSRZHUVXSSO\1RWGRLQJVRZLOOFDXVHWKH XQLWWRVWDUWRSHUDWLRQDXWRPDWLFDOO\ZKHQSRZHUVXSSO\LVUHVXPHG To the user $IWHULQVWDOOLQJWKHXQLWPDNHVXUHWRH[SODLQWKHXVHUDERXWDXWRUHVWDUWIXQFWLRQ ,I DXWR UHVWDUW IXQFWLRQ LV XQQHFHVVDU\ LW FDQ EH GHDFWLYDWHG &RQVXOW WKH VHUYLFH UHSUHVHQWDWLYHWRGHDFWLYDWHWKHIXQFWLRQ5HIHUWRWKHVHUYLFHPDQXDOIRUGHWDLOV 4-4. EXPLANATION TO THE USER 8VLQJWKH23(5$7,1*,16758&7,216H[SODLQWRWKHXVHUKRZWRXVHWKHDLUFRQGLWLRQHUKRZWRXVHWKHUHPRWHFRQWUROOHUKRZWRUHPRYHWKHDLU¿OWHUVKRZWRUHPRYH RUSXWWKHUHPRWHFRQWUROOHULQWKHUHPRWHFRQWUROOHUKROGHUKRZWRFOHDQSUHFDXWLRQV IRURSHUDWLRQHWF 5HFRPPHQGWKHXVHUWRUHDGWKH23(5$7,1*,16758&7,216FDUHIXOO\ 5. RELOCATION AND MAINTENANCE 5-1. REMOVING AND INSTALLING THE PANEL ASSEMBLY 5-3. PUMPING DOWN :KHQUHORFDWLQJRUGLVSRVLQJRIWKHDLUFRQGLWLRQHUSXPSGRZQWKHV\VWHPIROORZLQJWKH SURFHGXUHEHORZVRWKDWQRUHIULJHUDQWLVUHOHDVHGLQWRWKHDWPRVSKHUH &RQQHFWWKHJDXJHPDQLIROGYDOYHWRWKHVHUYLFHSRUWRIWKHVWRSYDOYHRQWKHJDVSLSH side of the outdoor unit. )XOO\FORVHWKHVWRSYDOYHRQWKHOLTXLGSLSHVLGHRIWKHRXWGRRUXQLW &ORVHWKHVWRSYDOYHRQWKHJDVSLSHVLGHRIWKHRXWGRRUXQLWDOPRVWFRPSOHWHO\VRWKDW LW FDQ EH HDVLO\ FORVHG IXOO\ ZKHQ WKH SUHVVXUH JDXJH VKRZV 03D >*DXJH@ NJI FP 6WDUWWKHHPHUJHQF\&22/RSHUDWLRQ To start the HPHUJHQF\ RSHUDWLRQ LQ &22/ PRGH GLVFRQQHFW WKH SRZHU VXSSO\ SOXJ DQGRU WXUQ RII WKH EUHDNHU $IWHU VHFRQGV FRQQHFW WKH SRZHU VXSSO\ SOXJ DQGRU WXUQ RQ WKH EUHDNHU DQG WKHQ SUHVV WKH (2 6: RQFH 7KH HPHUJHQF\ &22/ operationFDQEHSHUIRUPHGFRQWLQXRXVO\IRUXSWRPLQXWHV )XOO\FORVHWKHVWRSYDOYHRQWKHJDVSLSHVLGHRIWKHRXWGRRUXQLWZKHQWKHSUHVVXUH JDXJHVKRZVWR03D>*DXJH@DSSUR[WRNJIFP 6WRSWKHHPHUJHQF\&22/RSHUDWLRQ. 3UHVVWKH(26:WZLFHWRVWRSWKHRSHUDWLRQ Removal procedure 5HPRYHWKHVFUHZVZKLFK¿[WKHSDQHODVVHPEO\ 5HPRYH WKH SDQHO DVVHPEO\ %H VXUH WR UHPRYH LWVERWWRPHQG¿UVW Installation procedure ,QVWDOO WKH SDQHO DVVHPEO\ IROORZLQJ WKH UHPRYDO procedure in reverse. %HVXUHWRSUHVVWKHSRVLWLRQVDVLQGLFDWHGE\WKH DUURZVLQRUGHUWRDWWDFKWKHDVVHPEO\FRPSOHWHO\ to the unit. 5-2. REMOVING THE INDOOR UNIT 5HPRYHWKHERWWRPRIWKHLQGRRUXQLWIURPWKHLQVWDOODWLRQ plate. :KHQUHOHDVLQJWKHFRUQHUSDUWUHOHDVHERWKOHIWDQGULJKW ERWWRPFRUQHUSDUWRILQGRRUXQLWDQGSXOOLWGRZQZDUGDQG IRUZDUGDVVKRZQLQWKH¿JXUHRQWKHULJKW WARNING :KHQSXPSLQJGRZQWKHUHIULJHUDQWVWRSWKHFRPSUHVVRUEHIRUHGLVFRQQHFWLQJ the refrigerant pipes. The compressor may burst if air etc. get into it. If the above method cannot be used 5HPRYHWKHIURQWSDQHO7KHQLQVHUWKH[DJRQDOZUHQFKHVLQWRWKHVTXDUHKROHVRQWKH OHIWDQGULJKWVLGHVRIWKHXQLWDQGSXVKWKHPXSDVVKRZQLQWKHIROORZLQJ¿JXUH7KHERWWRPRIWKHLQGRRUXQLWORZHUVDQGUHOHDVHVWKHKRRNV 3XVK Square hole Lower +($'2)),&(72.<2%/'*0$58128&+,&+,<2'$.872.<2 -$3$1