Download cgl control panels - Pentair Water Literature
Transcript
MODELS CGL-01SW, CGL-01DW (2HP, 208V, 1PH) CGL-21SW, CGL-21DW (2HP, 230V, 1PH) CGL(LD)-21SW, CGL(LD)-21DW (2HP, 230V, 1PH) CGL-23SW, CGL-23DW (2HP, 208-230V, 3PH) CGL-43SW, CGL-43DW (2HP, 460V, 3PH) CGL CONTROL PANELS INSTALLATION AND SERVICE MANUAL For Simplex and Duplex. NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system. Part # 23833A150 | © 2012 Pentair Pump Group, Inc. | 11/08/12 LOCATION AND MOUNTING CALIFORNIA PROPOSITION 65 WARNING: OUTDOOR USE The control box may be mounted at the location of the pump and basin or may be mounted in a remote location. The box should be secured to a stable vertical support which in turn should be secured to a concrete basin or footer. The box could also be mounted to the side of the house or other stationary support if available within a reasonable distance. When selecting a location, you should consider the visibility of the alarm light. The box may be secured by the use of four mounting holes located in the mounting feet on the top and bottom of the box. The box should be mounted approximately 5 feet from the ground to the circuit breaker handle. This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. INDOOR USE Locate the control box in a convenient location, preferably close to the pump installation. The box may be secured to a wall or other stable vertical support by use of the four mounting holes located in the mounting feet on the top and bottom of the box. The box should be mounted approximately 5 feet from the floor to the circuit breaker handle. Care should be taken to avoid mounting the control box under sweating pipes, faucets or other damp locations. POWER SUPPLY WARNING Do not attempt to wire this control box unless you have a good working knowledge of electricity and are familiar with state and local codes. If you are in doubt about anything, contact an electrician. The power supply for the control box will vary depending upon which particular model you have purchased. Do not attempt to operate this unit on any other voltage or power distribution other than what it was originally designed. Failure to comply with this will result in the immediate cancellation of all warranties and claims. It is advisable to put the pump on its own circuit using a circuit breaker adequately sized to protect the pump. Check state and local codes for the correct wire size and circuit protection to use. The wire should be sized large enough to handle the full load current of both pumps you are operating, and any voltage drop that might occur due to long service runs. 23833A150 11/08/12 Run power supply lines to the control box and secure (knockouts are not supplied in this box). Select a convenient location on the bottom to enter the box with the power supply. Cut a hole with a chassis punch, caution should be taken not to get fiberglass chips in the components while cutting hole. After the hole is cut, any fiberglass particles must be removed from box. Failure to do so may result in premature component failure. Connect incoming power to the circuit breaker top lugs and all necessary ground wires to the ground lug at the bottom of the box. The ground lug should be fastened to a good driven earth ground by one of the methods described in the National Electric Code. NOTE: On single phase panels, the neutral terminal block (labeled “N” and located next to the circuit breaker) must be connected to the incoming power neutral line. If the incoming power does not have a neutral line, then the neutral terminal block should be jumpered to the ground lug. 2 CONNECTING PUMPS AND FLOATS TO CONTROL BOX PUMP CORD Run the wires from both pumps to the bottom of the control box by means of one of the methods described in your pump or basin installation instructions. A hole must be cut into the control box (use the same procedure as that described for incoming power supply lines). Connect red, white and black wires to terminals marked M1, M2 and M3 (for 3 phase applications), or connect the red, white and black wires to terminals marked R, W and B (for 1 phase applications). Fasten green wire to ground lug. WGL pumps may have an additional brown wire in the pump cord. This is for the seal leak probe and it should be connected to the terminal strip in the control box. See wiring diagram for the proper terminal connections. NOTE:On 3 phase installations check for proper pump rotation. See the “ROTATION OF 3 PHASE PUMPS” section in this manual. FLOAT CORDS See basin instructions for the proper depth at which to set the floats. Strip the float cord wires 3/8", twist strands together, and connect black and white wires to terminal strip in the control box. See wiring diagram for proper terminal connections. OPERATING PUMPS 1.Make sure that all wires are inside the control box and not in a position to be pinched or shorted when the door is closed. 2.Turn on power to the control box. 3.Turn hand-off-auto switches to the “HAND” position. The pumps should start and the pump run lights should come on. (On duplex panels, this should be done for both pumps). 4.To put into service, put the hand-off-auto switch in the “AUTO” position. (On duplex panels, this should be done fore both pumps). See basin instructions. 5.If unit does not operate as described, see troubleshooting chart. NOTE:Addition of electrical components and circuitry to this unit is expressly forbidden unless written factory authorization is obtained. Failure to do so will result in warranty cancellation. ROTATION OF THREE PHASE PUMPS IMPORTANT Rotation of three phase pumps must be established by one of the two methods described below. CAUTION Keep hands and feet clear of impeller when checking rotation. Be sure to disconnect power to the control box while handling pumps. Make sure pump is wired and readied for rotation test before the control box is energized. 1.Before positioning pump in basin, run wires to control box. Lay the pump unit on its side and secure so that the starting torque of the motor will not cause the pump to roll. Energize the pump by turning the circuit breaker on and the hand-off-auto to “HAND”. The rotation should be counterclockwise as observed facing the bottom of the pump. If you do not get the proper rotation, disconnect the power to the control box and change the position of any two of the black motor leads in the terminal blocks. 2.Install the pump in the basin and run in some water so the pump can operate. Energize the pump by turning the circuit breaker on and the hand-of-auto switch to “HAND”. Let the pump pull the water down in the basin, and when the water reaches the bottom of the pump the rotation of the water can be observed. The water should rotate in a clockwise direction if the pump rotation is correct. 3 If you do not get the proper rotation, disconnect the power to the control box and change the position of any two of the black motor leads in the terminal blocks. 23833A150 11/08/12 CHECKING PUMP CURRENT DRAW 1 PHASE PUMPS 1.Use an amprobe to check the amperage of the pump. 2.Turn the hand-off-auto switch to the “HAND” position and compare the amperage reading to the values shown on the chart. (See page 9). 3.If you get a reading of 0, make sure there is voltage to the motor leads. Push the Klixon overload reset button in the control panel. the on winding overload may be tripped. Wait 15 minutes and try again. If you still do not get a reading, either the motor has failed or there might be a wiring problem between the control panel and pump (improper connection in the junction box). 3.If you get a reading of 0, make sure there is voltage to the motor leads. Push the overload reset button on the overload relay in the control panel. If you still do not get a reading either the motor has failed or there might be a wiring problem between the control panel and pump (improper connection in the junction box). 4.If you get high amperage readings on 2 wires and a zero reading on the third, you have a single phase condition which could be caused by one of the following: A.One motor lead is not connected properly. B.You have lost 1 phase of the 3 phase power coming into the panel. C.One winding in the motor is open. 3 PHASE PUMPS 1.Use an amprobe to check the amperage of any of the power leads going to the pump. 2.Turn the hand-off-auto switch to the “HAND” position and compare the amperage reading to the values shown on the chart. CHECKING PUMP AND FLOAT RESISTANCE TO CHECK PUMP OR FLOAT, DISCONNECT INCOMING POWER AND REMOVE WIRES FROM THE TERMINAL BLOCK AND WITH AN OHMMETER CHECK THE MEASUREMENTS PER CHART. CORD MEASURED ITEM MEASURED CORRECT READING OHMMETER SETTING IF YOU GET ANY OTHER READING CHECK FOR THE FOLLOWING: Power Motor Winding Cord (1 Phase) (See Chart) R x 1 Damaged winding or cord Power Motor Winding Cord (3 Phase) (See Chart) R x 1 Damaged winding or cord Power Ground to Motor Winding Cord (Green to Red, Black or White) Infinity to 200 R x 100K Damaged winding or cord moisture in motor Power Ground to Seal Probe (Opt.) Cord (Green to Brown) Infinity to 200 R x 100K Water in seal chamber or damaged cord Float Ground to Float Contacts Cord (Green to Black or White) Infinity to 200 R x 100K Water in float or damaged cord R x 1 Switch has failed or damaged cord 0 - Float On Float Float Contacts Infinity-Float Off Cord (Black to White) NOTE: Readings may vary slightly depending on length of wire running to the motor and the accuracy of the measurement instrument. 23833A150 11/08/12 4 TESTING COMPONENTS IN CONTROL BOX WARNING To prevent electrical shock, disconnect power entering the control box and turn the circuit breaker in the control box to the “OFF” position. CONTRACTOR 1.Physically examine the contractor for badly burnt or sticking contacts. The contractor arm should move in and out freely. 2.Remove the wires on the coil to the contactor and measure the resistance. Zero the ohmmeter, and on the R x 1 scale you should read approximately 138 ohms. 3.Often a burnt coil can be spotted by merely looking to see if it is badly discolored or has a dark spot on it. TRANSFORMER (3 PHASE PANELS ONLY) 208 VOLT 1.Remove the wires from the primary side (H3-H4) and also from the secondary side (X2-XF-X1). 2.With an ohmmeter on the R x 1 scale touch terminals H3 and H4 (primary), you should get a reading of approximately 15.6 ohms for Simplex panels, and 5.8 ohms for Duplex panels. 3.With an ohmmeter on the R x 1 scale touch terminals X2 and X1 (secondary), you should get a reading of approximately 3.6 ohms for Simplex panels and 1.6 ohms for Duplex panels. 4.With an ohmmeter on the R x 1 scale touch terminals XF and X1, you should get a reading of 0. If you do not, replace the fuse. 230 VOLT 1.Remove the wires from the primary side (H2-H4) and also from the secondary side (X2-XF-X1). 2.With an ohmmeter on the R x 1 scale touch terminals H2 and H4 (primary), you should get a reading of approximately 14 ohms for Simplex panels, and 6.5 ohms for Duplex panels. 3.With an ohmmeter on the R x 1 scale touch terminals X2 and X1 (secondary), you should get a reading of approximately 3.6 ohms for Simplex panels and 1.6 ohms for Duplex panels. 4.With an ohmmeter on the R x 1 scale touch terminals XF and X1, you should get a reading of 0. If you do not, replace the fuse. 460 VOLT 1.Remove the wires from the primary side (H1-H4) and also from the secondary side (X2-XF-X1). 2.With an ohmmeter on the R x 1 scale touch terminals H1 and H4 (primary), you should get a reading of approximately 49.7 ohms for Simplex panels, and 21.5 ohms for Duplex panels. 3.With an ohmmeter on the R x 1 scale touch terminals X2 and X1 (secondary), you should get a reading of approximately 3.6 ohms for Simplex panels and 1.6 ohms for Duplex panels. 4.With an ohmmeter on the R x 1 scale touch terminals XF and X1, you should get a reading of 0. If you do not, replace the fuse. OVERLOAD BLOCK (3 PHASE PANELS ONLY) 1.Remove the wires from the terminals on the side of the overload block. 2.With an ohmmeter on the R x 1 scale touch the two terminals, you should get a reading of 0. If you do not get this reading, push the large black reset button on the front of the overload block. 3.You may test the inner switching mechanism by pushing the small black button on the front of the overload block to trip the switch and pushing the large black button to reset it. If the inner switch does not work properly replace the overload block. OVERLOAD HEATERS (3 PHASE PANELS ONLY) 1.Remove the heaters from the overload block and examine them for physical damage. A slight discoloration is normal, but if they are melted or warped they should be replaced. FUSES 1.Pull the fuse out of the fuse block and check for continuity with an ohmmeter. 2.With an ohmmeter on the R x 1 scale, you should get a reading of 0. If you do not, replace it with the same type and rating that is shown on the decal located next to the fuse block. OVERRIDE RELAY (DUPLEX PANELS ONLY) 1.Physically examine the relay for burnt or stuck contacts and for a burnt or discolored coil. 2.Remove the relay from the socket and with an ohmmeter on R x 1000 scale, you should read approximately 7.68 ohms on pins 13 and 14. Often a burnt coil can be spotted by merely looking to see if it is badly discolored or has a dark spot on it. ALARM LIGHT 1.The light should activate when the alarm float con nections are jumpered, if not replace the light bulb. ALTERNATOR RELAY (DUPLEX PANELS ONLY) 1.When power is on and the relay is functioning properly, one of the two lights on top of the relay should be on. 2.With circuit breaker turned “off”, remove relay from socket. With an ohmmeter on the R x 1000 scale, touch the alternator coil terminals. The “black” lead 5 23833A150 11/08/12 TESTING COMPONENTS IN CONTROL BOX should be on pin 3, and the “red” lead should be on pin 5. You should have a reading of approximately 920-1020 ohms. 3.If alternator shows physical damage or does not test properly, replace it. KLIXON OVERLOAD (1 PHASE PANELS ONLY) 1.Remove black wire from the bottom of contactor and the white wire from the “B” terminal for the pump. Clip ohmmeter leads to the black and white wires and with the ohmmeter on R x 1, you should have a reading of 0. If you do not, push in on the reset button and check again. If you still do not read 0, replace overload. START AND RUN CAPACITOR NOTE: A good sign of a failed capacitor is a bulged or swollen enclosure, leaking oil or a burnt smell. This is true on both types of capacitors. 1.With power shut off, short the terminals of the capacitors together with a screwdriver or jumper cables. This will discharge any voltage stored in the capacitor. 2.Remove the wires from the ends of the capacitor. 3.Set the ohmmeter on R x 10,000 (10K) and adjust needle to zero, after clipping the ohmmeter leads together. 4.Clip one lead to one side of the capacitor terminal 23833A150 11/08/12 and touch the other lead to the other capacitor terminal. If the capacitor is good, the needle will go towards zero and then drift slowly towards infinity. If the ohmmeter does not read as described, the capacitor is bad and must be replaced. 5.If the capacity is checked a second time, be sure to reverse the ohmmeter leads to get a correct reading. START RELAY 1.With the power shut off, disconnect the wires going to the relay. 2.Set the ohmmeter to R x 1,000 and adjust the needle to zero, after clipping the ohmmeter leads together. 3.Check the resistance between terminals 1 and 2 on the relay. If the relay is good, the ohmmeter will read 0. 4.Check the resistance between terminals 2 and 5. The ohmmeter should read approximately 6,000 ohms. If it reads 0 or infinity, the relay is bad. NOTE: The relay can check good according to the above test and still not work properly. The contacts between terminals 1 and 2, that disconnect the start winding, may be stuck or burnt together, keeping the winding in the circuit until the overload trips. If this happens, replace the relay. 6 Auto On H-I Position Hand- AutoRun Switch Light Check 7 AutoOff- Hand Auto- On Off- Or Hand Off Fuse in Control Circuit Blown Control Box Buzzes Off L G-H-K-I F-J AutoOff- Hand Circuit Breaker Tripped Off Auto OffA-H-D-F Auto OrOnG-I Hand Alarm Activates Hand OffA-C-BPump D-F Does Not Run Auto OffA-F-C-BE-D-H Problem Pump Does Not Turn Off (3 PHASE ONLY) Reset by pushing overload reset button. If overload does not trip again problem may be fixed. If overload trips again, check power supply voltage. Check motor winding resistance, make sure pump shaft is not locked. Reset breakers or replace fuses. If they continue to blow, check amp capacity of wire and breakers. Make sure it is wired properly and that you have the correct power supply system. (See instructions “Power Supply”). Reset by pushing handle down to “OFF” position and resetting to “ON” position. Make sure that wires are not shorted and that the box is wired properly. Check fuse per instructions. Replace fuse with same type and rating. Check basin. Run pump manually to see if pump operates properly. B Tripped circuit breaker or CTripped circuit breaker DControl circuit fuse blown. E Level in basin may not be Check wiring per wiring diagram. Make sure pump is connected to terminal block properly. Reduce water flow. Pump may need servicing. Operate manually to see if basin pumps down and alarm goes off. Repair float if necessary. GToo much water coming HFloat switch may have or wrong voltage components. L Wrong operating voltage operating coil. K May be failed component Check voltage and make sure relays and contactors are of proper voltage. Check components per instructions. Check wiring. (Short will not be located in control cucuit unless control circuit fuse is blown). Check motor. (See chart for checking pump cables). J May be short circuit in wiring or pump power supply–Short in motor. Pull pump and check discharge line and pump inlet. (CAUTION: Never put hands on grinder impeller unless power is turned off). I Pump or discharge line may be plugged. failed. into basin. F May not be wired properly. high enough to turn switch on. in control panel. fuse at power supply panel. (1 PHASE ONLY) Reset by pushing Klixon overload reset button. If overload trips again, check power supply voltage. Check motor winding resistance, make sure pump shaft is not locked. CAUSEREMEDY A Motor overload tripped. TROUBLESHOOTING CHART (SIMPLEX PANELS) 23833A150 11/08/12 23833A150 11/08/12 Hand OffC-E-B-G Pump 1 AND 2 Will Not Run HandOnA-G-K HandOffC-G-L Auto OnA-G-K-L Auto OffM-F-G Pump 1 OR 2 Will Not Run 8 Auto- Off- Hand Auto- On Off- or Hand Off Fuse in Control Circuit Blown Control Box Buzzes Off Auto- Off- Off Hand L H-I-J-K G-N No Auto E-L Run Light On Circuit Breaker Tripped Alarm Activates Only One Auto G-D Light On Both AutoLights H-I-J On AutoOff F-I-CB-E-G Auto OnA-G-L-K Hand OnG-A-L-K Position Hand- AutoRun Switch Light Check Problem (3 PHASE ONLY) Reset by pushing overload reset button. If overload does not trip again problem may be fixed. If overload trips again, check power supply voltage. Check motor winding resistance, make sure pump shaft is not locked. Reset breakers or replace fuses. If they continue to blow, check amp capacity of wire and breakers. Make sure it is wired properly and that you have the correct power supply system. (See instructions “Power Supply”). B Tripped circuit breaker or Reset by pushing handle down to “OFF” position and resetting to “ON” position. Make sure that wires are not shorted and that the box is wired properly. Try operating both pumps in “HAND” position. If the run light comes on and pumps operate properly, replace override relay. Check fuse per instructions. Replace fuse with same type and rating. Check basin. Run pump manually to see if pump operates properly. DOverride relay not working properly E Control circuit fuse blown. F Level in basin may not be Check wiring per wiring diagram. Make sure pump is connected to terminal block properly. Reduce water flow. Pump may need servicing. HToo much water coming Pull pump and check discharge line and pump inlet. (CAUTION: Never put hands on grinder impeller unless power is turned off). Check components per instructions. J Pump or discharge line K May be failed component wiring or pump power supply—Short in motor. NMay be short in circuit in alternating phase — alternator may not be working properly. MMay not be lead pump in or wrong voltage components. L Wrong operating voltage operating coil. may be plugged. Check wiring. (Short will not be located in control circuit unless control circuit fuse is blown). Check motor. (See chart for checking pump cables). Let float switches cycle basin to see if alternator is alternating pumps. If not check alternator relay per instructions. Check voltage and make sure relays and contactors are of proper voltage. Operate manually to see if basin pumps down and alarm goes off. Repair float if necessary. failed. I Float switch may have into basin. GMay not be wired properly. high enough to turn switch on. in control panel. CTripped circuit breaker fuse at power supply panel. – wrong supply voltage (1 PHASE ONLY) Reset by pushing Klixon overload reset button. If overload trips again, check power supply voltage. Check motor winding resistance, make sure pump shaft is not locked. CAUSEREMEDY A Motor overload tripped. TROUBLESHOOTING CHART (DUPLEX PANELS) PUMP CURRENT DRAW, WINDING RESISTANCE OVERLOAD HEATER SELECTION* RESISTANCE MODEL HP VOLTAGE PHASE RPM F.L.A. L.R.A. BLK-WH BLK-RED WH-RED HEATER HEATER NO. WGL20-01 2 WGL20-21 2 208 230 1 1 3450 3450 15.0 12.5 52.5 1.14-1.264.63-5.11 5.77-6.37 44.0 1.46-1.627.20-8.00 8.66-9.62 — — — — WGL20-03 2 WGL20-23 2 WGL20-43 2 208 230 460 3 3 3 3450 3450 3450 9.5 8.4 4.2 34.0 2.65-2.932.65-2.93 2.65-2.93 32.5 3.12-3.453.12-3.45 3.12-3.45 16.3 12.5-13.812.5-13.8 12.5-13.8 K50 K49 K34 13621A091 13621A062 13621A104 *WARNING:On 3 phase panels, overload heater elements are not factory installed in the overload relay. Elements must be purchased separately and correspond with the above chart. This must be done before the panel is put into service. Failure to install the elements before the panel is put into service, or failure to install the correct size elements, may result in pump failure. All pump and panel warranties will be void if the above guidelines are not followed NOTICE All standard CGL (Simplex) Series control panels manufactured after July 1, 1993 will have the following changes: Pump Run Light Ass’y. Seal Leak Light Ass’y. Previous Part No. 21973A002 (Holder) 21974A001 (Bulb) 21973A001 (Holder) 21974A001 9 New Part No. 21973A013 21973A012 (Bulb) 23833A150 11/08/12 USE COPPER WIRE ONLY OVERLOAD PUSH IN TO RESET PUMP RUN PUMP AUTO OFF HAND LIGHT SEAL LEAK 23833A150 11/08/12 10 1 AMP, 230V, ABC-1 ALARM CIRCUIT FUSE 1 AMP, 230V, ABC-1 CONTROL CIRCUIT FUSE LIGHT 1 2 3 4 5 6 7 R W B GRD. 13-3/8 10 5/16 DIA. 15-5/16 14-5/8 15-1/2 7-23/32 ALARM LIGHT (22000A020 OR 22000A011) FLASHER (22002A001) END SECTION (21996A000) TERMINAL BLK. (21995A000) ENCLOSURE (21981C106A) BACK PANEL (21981C110A) CIRCUIT BREAKER (21985A001) START RELAY (21990A000) CAPACITOR BRACKET (2) (21989A002) USE COPPER WIRE ONLY U.L. LABEL OVERLOAD PUSH IN TO RESET PUMP RUN PUMP AUTO OFF WIRING DIAGRAM LIGHT HAND MOUNTING BRACKET (21997B024) START CAPACITOR (12141A005) KLIXON OVERLOAD (20704A008) TOGGLE SWITCH (21979A003) LIGHT ASSEMBLY (21973A002) LIGHT BULB (2) (21974A001) RUN CAPACITOR (23185A000) LIGHT ASSEMBLY (21973A001) SEAL LEAK CAT. NO. CGL-021SW FUSE HOLDER (2) (21991A001) 11 1 AMP, 230V, ABC-1 ALARM CIRCUIT FUSE 1 AMP, 230V, ABC-1 CONTROL CIRCUIT FUSE LIGHT END SECTION (21996A000) GROUND LUG (21994A001) 1 2 3 4 5 6 7 R W B GRD. CONTACTOR (22914A005) TERMINAL BLK. (10) (21995A000) FUSE (2) (20514A009) 23833A150 11/08/12 13-3/8 10 5/16 DIA. 15-5/16 14-5/8 15-1/2 7-23/32 ALARM LIGHT (22000A020 OR 22000A011) FLASHER (22002A001) END SECTION (21996A000) TERMINAL BLK. (21995A000) ENCLOSURE (21981C106A) BACK PANEL (21981C110A) CIRCUIT BREAKER (21985A001) START RELAY (21990A000) CAPACITOR BRACKET (2) (21989A002) USE COPPER WIRE ONLY U.L. LABEL OVERLOAD PUSH IN TO RESET PUMP RUN PUMP AUTO OFF WIRING DIAGRAM HAND MOUNTING BRACKET (21997B024) START CAPACITOR (12141A005) KLIXON OVERLOAD (20704A008) TOGGLE SWITCH (21979A003) LIGHT ASSEMBLY (21973A002) LIGHT BULB (21974A001) RUN CAPACITOR (23185A000) LIGHT CAT. NO. CGL(LD)-21SW 23833A150 11/08/12 FUSE HOLDER (2) (21991A001) 12 1 AMP, 230V, ABC-1 ALARM CIRCUIT FUSE 1 AMP, 230V, ABC-1 CONTROL CIRCUIT FUSE END SECTION (21996A000) GROUND LUG (21994A001) 1 2 3 4 5 6 R W B GRD. CONTACTOR (22914A005) FUSE (2) (20514A009) TERMINAL BLK. (9) (21995A000) 15-27/64 12 5/16 DIA. 17-7/16 16-3/4 17-1/2 7-11/16 ALARM LIGHT (22000A020 OR 22000A011) FLASHER (22002A001) BACK PANEL (21981C111A) CIRCUIT BREAKER (21985A003) ENCLOSURE (21981C107A) MOUNTING BRACKET (21997B022) U.L. LABEL TOGGLE SWITCH (21979A003) PUMP AUTO LIGHT ASSEMBLY (21973A002) PUMP RUN OFF HAND LIGHT BULB (2) (21974A001) LIGHT ASSEMBLY (21973A001) LIGHT SEAL LEAK LIGHT WIRING DIAGRAM 1 AMP, 250V, ABC-1 ALARM CIRCUIT FUSE FUSE HOLDER (21991A001) FUSE (20514A000) TRANSFORMER (22053A010) 1 AMP, 250V, FNM-1 CONTROL CIRCUIT FUSE 1 2 FUSE (22514A007) 3 4 5 6 7 M1 M2 M3 GRD. CAT. NO. CGL-23SW FUSE (2) (20514A014) MAGNETIC STARTER (24024A008) AUX. CONTACT (22913A010) 13 GROUND LUG (21994A001) END SECTION (21996A000) TERMINAL BLK. (10) (21995A000) 23833A150 11/08/12 15-27/64 12 5/16 DIA. 17-7/16 16-3/4 17-1/2 7-11/16 ALARM LIGHT (22000A020 OR 22000A011) FLASHER (22002A001) BACK PANEL (21981C111A) CIRCUIT BREAKER (22362A001) ENCLOSURE (21981C107A) MOUNTING BRACKET (21997B022) U.L. LABEL TOGGLE SWITCH (21979A003) ON PUMP AUTO LIGHT ASSEMBLY (21973A002) PUMP RUN OFF OFF HAND LIGHT BULB (2) (21974A001) LIGHT ASSEMBLY (21973A001) LIGHT SEAL LEAK LIGHT WIRING DIAGRAM 1 AMP, 250V, ABC-1 ALARM CIRCUIT FUSE FUSE HOLDER (21991A001) FUSE (20514A009) TRANSFORMER (22053A010) 1 AMP, 250V, FNM-1 CONTROL CIRCUIT FUSE 1 2 FUSE (20514A007) 3 4 5 6 7 M1 M2 M3 GRD. CAT. NO. CGL-43SW 23833A150 11/08/12 FUSE (2) (20514A012) MAGNETIC STARTER (24024A008) AUX. CONTACT (22913A010) 14 GROUND LUG (21994A001) END SECTION (21996A000) TERMINAL BLK. (10) (21995A000) 17-31/64 12 5/16 DIA. 19-31/64 18-7/8 19-5/8 10-5/8 ALARM LIGHT (22000A020 OR 22000A011) FLASHER (22002A001) CIRCUIT BREAKER (2) (21985A001) END SECTION (21996A000) TERMINAL BLK. (21995A000) ENCLOSURE (21981C108A) BACK PANEL (21981C112A) START RELY (2) (21990A002) CAPACITOR BRACKET (2) (16754A003) USE COPPER WIRE ONLY U.L. LABEL START CAPACITOR (2) (22747A000) END CAP (2) (20332A004) CAPACITOR BRKT. (2) (16754A002) RUN CAPACITOR (2) (23185A000) CONTACTOR (2) (22914A005) MOUNTING BRKT. (21997C025) FUSE (2) (20514A009) WIRING DIAGRAM OVERLOAD KLIXON OVERLOAD (2) (20704A008) OVERLOAD FUSE HOLDER (2) (21991A001) PUSH IN TO RESET 1 AMP, 250V, ABC-1 ALARM CIRCUIT FUSE 1 AMP, 250V, ABC-1 CONTROL CIRCUIT FUSE OVERRIDE RELAY (23634A005) LOAD 1 RELAY SOCKET (23527A000) 2 3 4 5 6 7 1 2 3 4 5 6 HAND HAND PUMP 1 RUN PUMP 2 RUN PUMP 1 SEAL LEAK PUMP 2 SEAL LEAK LIGHT BULB (4) (21974A001) LIGHT ASSEMBLY (2) (21973A001) GRD. GROUND LUG (2) (21994A001) ALTERNATOR RELAY (22045A001) TERMINAL BLK. (16) (21995A000) 15 OFF 7 GRD. CAT. NO. CGL-01DW LIGHT ASSEMBLY (2) (21973A002) PUMP AUTO OFF RELAY SOCKET (23527A002) 1 PUSH IN TO RESET PUMP AUTO LOAD 2 TOGGLE SWITCH (2) (21979A003) END SECTION (2) (21996A000) 23833A150 11/08/12 17-31/64 12 5/16 DIA. 19-31/64 18-7/8 19-5/8 10-5/8 ALARM LIGHT (22000A020 OR 22000A011) FLASHER (22002A001) CIRCUIT BREAKER (2) (21985A001) END SECTION (21996A000) TERMINAL BLK. (21995A000) ENCLOSURE (21981C108A) BACK PANEL (21981C112A) START RELY (2) (21990A002) USE COPPER WIRE ONLY U.L. LABEL CAPACITOR BRKT (4) (16754A002) START CAPACITOR (2) (12141A005) RUN CAPACITOR (2) (23185A000) MOUNTING BRKT. (21997C025) CONTACTOR (2) (22914A005) FUSE (2) (20514A009) WIRING DIAGRAM 1 AMP, 250V, ABC-1 ALARM CIRCUIT FUSE 1 AMP, 250V, ABC-1 CONTROL CIRCUIT FUSE OVERRIDE RELAY (23634A005) OVERLOAD PUSH IN TO RESET PUSH IN TO RESET KLIXON OVERLOAD (2) (20704A008) LOAD 1 1 RELAY SOCKET (23527A000) 2 3 4 5 6 7 1 2 3 4 5 6 ALTERNATOR RELAY (22054A001) TERMINAL BLK. (16) (21995A000) 16 HAND PUMP 1 RUN PUMP 2 RUN PUMP 1 SEAL LEAK PUMP 2 SEAL LEAK GRD. GROUND LUG (2) (21994A001) CAT. NO. CGL-21DW HAND 7 GRD. LIGHT ASSEMBLY (2) (21973A002) OFF OFF LOAD 2 TOGGLE SWITCH (2) (21979A003) PUMP AUTO PUMP AUTO RELAY SOCKET (23527A002) 23833A150 11/08/12 OVERLOAD FUSE HOLDER (2) (21991A001) END SECTION (2) (21996A000) LIGHT BULB (4) (21974A001) LIGHT ASSEMBLY (2) (21973A001) 17-31/64 12 5/16 DIA. 19-31/64 18-7/8 19-5/8 10-5/8 ALARM LIGHT (22000A020 OR 22000A011) FLASHER (22002A001) CIRCUIT BREAKER (2) (21985A001) END SECTION (21996A000) TERMINAL BLK. (21995A000) ENCLOSURE (21981C108A) BACK PANEL (21981C112A) START RELY (2) (21990A000) USE COPPER WIRE ONLY U.L. LABEL CAPACITOR BRKT. (4) (16754A002) START CAPACITOR (2) (12141A005) RUN CAPACITOR (2) (23185A000) MOUNTING BRKT. (21997C025) CONTACTOR (2) (22914A005) FUSE (2) (20514A009) WIRING DIAGRAM OVERLOAD OVERLOAD PUSH IN TO RESET PUSH IN TO RESET KLIXON OVERLOAD (2) (20704A008) FUSE HOLDER (2) (21991A001) 1 AMP, 250V, ABC-1 ALARM CIRCUIT FUSE 1 AMP, 250V, ABC-1 CONTROL CIRCUIT FUSE OVERRIDE RELAY (23634A005) RELAY SOCKET (23527A002) R RELAY SOCKET (23527A000) W B 1 2 3 4 5 6 7 8 9 W HAND PUMP 2 RUN PUMP 1 SEAL LEAK PUMP 2 SEAL LEAK LIGHT BULB (2) (21974A001) GRD. GROUND LUG (2) (21994A001) ALTERNATOR RELAY (22054A001) TERMINAL BLK. (14) (21995A000) 17 HAND PUMP 1 RUN B GRD. CAT. NO. CGL(LD)-21DW OFF OFF LOAD 1 LIGHT ASSEMBLY (2) (21973A002) PUMP AUTO PUMP AUTO LOAD 2 TOGGLE SWITCH (2) (21979A003) END SECTION (2) (21996A000) 23833A150 11/08/12 17-31/64 12 5/16 DIA. 19-31/64 18-7/8 19-5/8 10-5/8 ALARM LIGHT (22000A020 OR 22000A011) FLASHER (22002A001) ENCLOSURE (21981C108A) BACK PANEL (21981C112A) CIRCUIT BREAKER (2) (21985A003) MOUNTING BRKT. (21997C027) USE COPPER WIRE ONLY PUMP 2 PUMP 1 AUTO AUTO U.L. LABEL OFF OFF HAND HAND PUMP 1 RUN PUMP 2 RUN PUMP 1 SEAL LEAK PUMP 2 SEAL LEAK TOGGLE SWITCH (2) (21979A003) LIGHT ASSEMBLY (2) (21973A002) LIGHT BULB (4) (21974A001) LIGHT ASSEMBLY (2) (21973A001) FUSE HOLDER (21991A001) FUSE (20514A009) RELAY SOCKET (23527A002) 1 AMP, 250V, ABC-1 ALARM CIRCUIT FUSE OVERRIDE RELAY (23634A005) FUSE (2) (20514A014) TRANSFORMER (22053A001) FUSE (20514A007) WIRING DIAGRAM LOAD 2 LOAD 1 AUX. CONTACT (2) (22913A010) MAGNETIC STARTER (2) (24024A008) M1 M2 M3 1 2 3 1 AMP, 250V, FNM-1 CONTROL CIRCUIT FUSE 4 GRD. GROUND LUG (2) (21994A001) CAT. NO. CGL-23DW 23833A150 11/08/12 18 END SECTION (2) (21996A000) 5 6 7 8 9 10 M1 M2 M3 GRD. TERMINAL BLK. (16) (21995A000) RELAY SOCKET (23527A000) ALTERNATOR RELAY (22054A001) 17-31/64 12 5/16 DIA. 19-31/64 18-7/8 19-5/8 10-5/8 ALARM LIGHT (22000A020 OR 22000A011) FLASHER (22002A001) ENCLOSURE (21981C108A) BACK PANEL (21981C112A) CIRCUIT BREAKER (2) (22362A001) MOUNTING BRKT. (21997C027) USE COPPER WIRE ONLY PUMP 2 PUMP 1 AUTO AUTO U.L. LABEL ON ON OFF OFF TOGGLE SWITCH (2) (21979A003) OFF OFF HAND HAND PUMP 1 RUN PUMP 2 RUN PUMP 1 SEAL LEAK PUMP 2 SEAL LEAK LIGHT ASSEMBLY (2) (21973A002) LIGHT BULB (4) (21974A001) LIGHT ASSEMBLY (2) (21973A001) FUSE HOLDER (21991A001) FUSE (20514A009) RELAY SOCKET (23527A002) OVERRIDE RELAY (23634A005) FUSE (2) (20514A012) TRANSFORMER (22053A011) FUSE (20514A007) 1 AMP, 250V, ABC-1 ALARM CIRCUIT FUSE WIRING DIAGRAM LOAD 2 LOAD 1 AUX. CONTACT (2) (22913A010) MAGNETIC STARTER (2) (24024A008) R W B 1 2 3 4 GRD. GROUND LUG (2) (21994A001) CAT. NO. CGL-43DW 19 RELAY SOCKET (23527A000) ALTERNATOR RELAY (22054A001) 1 AMP, 250V, FNM-1 CONTROL CIRCUIT FUSE END SECTION (2) (21996A000) R W B 1 2 3 4 GRD. TERMINAL BLK. (16) (21995A000) 23833A150 11/08/12 1 AMP FUSE 3 1 R PUMP ON PUMP OFF HAND OFF AUTO 4 WH/YEL GRAY VIO 7 M1 6 VIO WH/VIO 1 RED M1 F YEL/RED WH/GRAY BLK TO SEAL LEAK PROBE IN PUMP WH/RED SR SR 2 YEL YEL CAT. NO. CGL-01SW 208 VOLT, 1 PHASE FLOAT CONTROLS MUST BE RATED FOR 2 AMPS AT 115 VOLTS 1 2 3 4 NOTE: DEPENDING ON PUMP MODEL, SEAL LEAK CIRCUIT MAY OR MAY NOT BE USED 2 5 HIGH WATER NOTE: CONNECT ALL GREEN WIRES TO GROUND BAR OR OR BLUE BRN 5 BLK R W B RED WH BLK PUMP MOTOR WH WH R-SEAL LEAK LIGHT (RED) M1-MOTOR CONTACTOR Y-RUN LIGHT (YELLOW) F-FLASHER AL-ALARM LIGHT (RED) GRN 7 R W B N START CAPACITOR RUN CAPACITOR 5 6 M1 Y AL KLIXON OVERLOAD WH PUMP OFF 1 AMP FUSE M1 M1 WH BLK PUMP ON BLUE BLK BLK 20A BREAKER WH BLK HIGH WATER L2 BRN RED WH BLK L1 POWER COR D INCOMING 200V 1 PH 1 AMP FUSE L2 OR OR BLUE 3 1 BRN BLUE 4 2 WH/YEL GRAY VIO 7 M1 HIGH WATER 5 6 BLK BLK 20A BREAKER VIO WH/VIO 5 1 RED M1 F YEL YEL 1 2 YEL/RED WH/GRAY BLK CAT. NO. CGL-21SW 230 VOLT, 1 PHASE FLOAT CONTROLS MUST BE RATED FOR 2 AMPS AT 115 VOLTS SR SR 2 BLK R W B RED WH BLK PUMP MOTOR WH WH AL-ALARM LIGHT (RED) GRN 7 R W B R-SEAL LEAK LIGHT (RED) M1-MOTOR CONTACTOR Y-RUN LIGHT (YELLOW) F-FLASHER 5 6 N START CAPACITOR RUN CAPACITOR 3 4 M1 Y AL KLIXON OVERLOAD TO SEAL LEAK PROBE IN PUMP WH/RED M1 M1 NOTE: CONNECT ALL GREEN WIRES TO GROUND BAR R PUMP ON PUMP OFF HAND OFF AUTO 1 AMP FUSE L1 INCOMING 230V 1 PH PUMP OFF 20 WH BLK PUMP ON MAIN WH BRN RED WH BLK START WH BLK HIGH WATER MAIN POWER COR D 23833A150 11/08/12 START BLK BLK 1 AMP FUSE 3 1 PUMP ON PUMP OFF HAND OFF AUTO BRN 4 GRAY VIO 6 M1 HIGH WATER 2 5 VIO WH/VIO 5 WH/RED M1 M1 1 2 SR SR 1 2 RED 3 4 M1 F 5 6 YEL/RED WH/GRAY BLK BLK M1 Y GRN R W B WH WH N M1-MOTOR CONTACTOR Y-RUN LIGHT (YELLOW) F-FLASHER AL-ALARM LIGHT (RED) START CAPACITOR PUMP MOTOR YEL RED WH BLK RUN CAPACITOR R W B YEL AL KLIXON OVERLOAD CAT. NO. CGL(LD)-21SW 230 VOLT, 1 PHASE FLOAT CONTROLS MUST BE RATED FOR 2 AMPS AT 115 VOLTS NOTE: CONNECT ALL GREEN WIRES TO GROUND BAR OR OR BLUE 1 AMP FUSE BLUE BLK BLK WH BLK PUMP ON 20A BREAKER WH BLK HIGH WATER L2 RED WH BLK L1 POWER COR D INCOMING 230V 1 PH WH PUMP OFF 3 1 R PUMP ON PUMP OFF HAND OFF AUTO 4 2 5 VIO 7 M1 6 VIO BLUE H1 H3 1 H2 2 F X2 H4 BLK M1 M1 GRN RED YEL/RED 3 4 5 6 T.O.C. Y WH WH GRN 7 M1 M2 M3 R-SEAL LEAK LIGHT (RED) TOC-THERMAL OVERLOAD CONTACT M1-MOTOR CONTACTOR Y-RUN LIGHT (YELLOW) F-FLASHER AL-ALARM LIGHT (RED) PUMP MOTOR CAT. NO. CGL-23SW OR CGL-43SW 208, 230 OR 460 VOLT, 3 PHASE FLOAT CONTROLS MUST BE RATED FOR 2 AMPS AT 115 VOLTS 1 2 WHITE AL M3 M2 M1 100VA TRANSFORMER TO SEAL LEAK PROBE IN PUMP WH/VIO WH/RED X1 BLK OVERLOAD ELEMENTS NOTE: DEPENDING ON PUMP MODEL, SEAL LEAK CIRCUIT MAY OR MAY NOT BE USED WH/YEL GRAY HIGH WATER 1 AMP FUSE 5 PRIMARY FUSES M1 M1 M1 NOTE: CONNECT ALL GREEN WIRES TO GROUND BAR OR OR OR XF 1 AMP FUSE BLK CIRCUIT BREAKER 208 - 230 V - 15 AMP 460V - 15 AMP WH PUMP OFF L1 L2 L3 WH BLK PUMP ON INCOMING 3 PH 208V, 230V, 460V WH BLK HIGH WATER 21 POWER COR D MAIN BRN RED WH BLK START BLK BLK 23833A150 11/08/12 R W YEL YEL RED WH B RED 6 4 2 8 R R FLOAT CONTROLS MUST BE RATED FOR 2 AMPS AT 115 VOLTS 7 5 3 BLK 9 WH/BRN AR AR 2 1 8 WH/RED WH/YEL OR WH/BLUE F 12 6 M2 WH/GRAY M1 GRN 10 1 2 3 4 5 6 7 8 9 TO SEAL LEAK PROBE IN PUMP 2 TO SEAL LEAK PROBE IN PUMP 1 5 OR 13 GRN WH N 1 2 YEL YEL R RED WH BLK START CAP. RUN CAP. R- SEAL LEAK LIGHT (RED) OR-OVERRIDE RELAY M2-MOTOR CONTACTOR AR- ALTERNATOR RELAY M1-MOTOR CONTACTOR Y-RUN LIGHT (YELLOW) F-FLASHER AL-ALARM LIGHT (RED) WH/GRAY RED W B PUMP MOTOR PUMP MOTOR RUN CAP. YEL R W B RED 8 R R FLOAT CONTROLS MUST BE RATED FOR 2 AMPS AT 115 VOLTS 7 5 3 BLK 5 M1 9 OR GRN AR AR L1 L2 F 12 6 6 7 8 9 TO SEAL LEAK PROBE IN PUMP 2 M2 WH/GRAY M1 OR BLK CAT. NO. CGL-21DW 230 VOLT, 1 PHASE WH WH SR SR BLK GRN 13 WH 3 WH 10 R W B 14 M2 Y 4 AR M1 Y 5 N 1 2 RED WH BLK YEL YEL R W B PUMP MOTOR START CAP. RUN CAP. R- SEAL LEAK LIGHT (RED) OR-OVERRIDE RELAY M2-MOTOR CONTACTOR AR- ALTERNATOR RELAY M1-MOTOR CONTACTOR Y-RUN LIGHT (YELLOW) F-FLASHER AL-ALARM LIGHT (RED) WH/GRAY RED KLIXON OVERLOAD BLK AL M2 M2 BLUE/RED 5 BLK BLK YEL/RED 20A BREAKER TO SEAL LEAK PROBE IN PUMP 1 WH/YEL OR WH/BLUE 4 5 2 1 8 WH/RED WH/BRN M2 2 3 10 1 GRAY WH/BLK M1 WH/BLUE WH/BLK VIOLET 9 BLK R W B 1 WH/VIO WH/BRN OVERRIDE AUTO OFF WH/YEL PUMP ON 1 SR SR BLK BLK M1 HIGH WATER 2 PUMP OFF HAND 6 4 2 AUTO OFF HAND BRN WH/GRAY RED NOTE: CONNECT ALL GREEN WIRES TO GROUND BAR OR OR OR OR OR ORANGE 1 AMP FUSE 1 AMP FUSE START CAP. YEL RED WH BLK KLIXON OVERLOAD BLK INCOMING 208V 1 PH 20A BREAKER BLK CAT. NO. CGL-01DW 208 VOLT, 1 PHASE WH WH SR SR 3 WH 10 R W B 14 M2 Y 4 AR 5 BLK KLIXON OVERLOAD BLK M1 Y AL M2 M2 BLUE/RED YEL/RED BLK BLK NOTE: DEPENDING ON PUMP MODEL, SEAL LEAK CIRCUIT MAY OR MAY NOT BE USED OR GRAY WH/BLK M2 M1 WH/BLUE WH/BLK VIOLET 9 BLK R W B 1 WH/VIO WH/BRN OVERRIDE AUTO OFF HAND SR 5 M1 BLK M1 HIGH WATER 1 BLK SR WH/YEL PUMP ON PUMP OFF AUTO OFF HAND BRN WH/GRAY RED 2 NOTE: CONNECT ALL GREEN WIRES TO GROUND BAR OR OR OR OR OR ORANGE 1 AMP FUSE 1 AMP FUSE START CAP. RUN CAP. RED 20A BREAKER WH BLK OVERRIDE BLK POWER COR D PUMP 1 L1 L2 WH BLK HIGH WATER KLIXON OVERLOAD BLK RED WH BLK BRN INCOMING 208V 1 PH POWER COR D PUMP 2 RED PUMP MOTOR PUMP OFF WH PUMP ON WH BLK BRN RED WH BLK START RED WH BLK BRN 20A BREAKER POWER COR D PUMP 1 22 WH PUMP OFF 23833A150 11/08/12 WH BLK PUMP ON START WH BLK OVERRIDE MAIN WH BLK HIGH WATER MAIN BRN RED WH BLK MAIN POWER COR D PUMP 2 MAIN START START 1 AMP FUSE OR OR 5 3 1 OVERRIDE AUTO OFF HAND WH/YEL PUMP ON PUMP OFF AUTO OFF HAND 5 6 4 2 5 9 WH/BRN M2 AR AR GRN R W B OR GRAY WH/BLK M1 WH/BLUE F 3 4 2 WH/YEL OR WH/BLUE 1 2 1 8 WH/RED 12 6 5 6 M2 WH/GRAY M1 5 7 8 13 WH 3 WH WH WH SR 1 SR BLK 2 N RED RED WH BLK YEL YEL R W B PUMP MOTOR START CAP. RUN CAP. OR-OVERRIDE RELAY M2-MOTOR CONTACTOR AR- ALTERNATOR RELAY M1-MOTOR CONTACTOR Y-RUN LIGHT (YELLOW) F-FLASHER AL-ALARM LIGHT (RED) WH/GRAY GRN R W B OR M2 Y 4 AR M1 Y 5 KLIXON OVERLOAD BLK AL M2 14 BLUE/RED YEL/RED BLK BLK M2 BLK CAT. NO. CGL(LD)-21DW 230 VOLT, 1 PHASE FLOAT CONTROLS MUST BE RATED FOR 2 AMPS AT 115 VOLTS 8 BLK WH/BLK VIOLET HIGH WATER 1 SR SR BLK NOTE: CONNECT ALL GREEN WIRES TO GROUND BAR OR RED ORANGE 2 7 WH/GRAY YEL BRN RED YEL R W 1 AMP FUSE START CAP. RUN CAP. RED WH BLK M1 WH PUMP OFF B WH BLK PUMP ON RED 20A BREAKER WH BLK OVERRIDE PUMP MOTOR BLK RED WH BLK L1 L2 WH BLK HIGH WATER M1 POWER COR D PUMP 1 INCOMING 230V 1 PH RED WH BLK 20A BREAKER POWER COR D PUMP 2 BLK KLIXON OVERLOAD BLK OR OR XF 4 M1 M1 BRN 8 AUTO OFF HAND 9 GRAY WH/BRN M2 AR AR OR WH/BLUE X1 F H1 2 WH/YEL 1 WH/RED BLUE PRIMARY FUSES 12 6 H3 5 14 RED GRN 10 1 2 3 4 5 6 7 8 9 TO SEAL LEAK PROBE IN PUMP 2 TO SEAL LEAK PROBE IN PUMP 1 13 GRN 10 M1 M2 M3 OR WH 3 WH T.O.C. Y 4 AR WH WH WHITE T.O.C. Y AL GRN RED BLUE/RED M2 M2 WH/GRAY H4 150 VA TRANSFORMER YEL/RED X2 M1 M1 H2 BLK BLK M1 PUMP MOTOR R- SEAL LEAK LIGHT (RED) OR-OVERRIDE RELAY M2-MOTOR CONTACTOR AR- ALTERNATOR RELAY TOC - THERMAL OVERLOAD CONTACT M1-MOTOR CONTACTOR Y-RUN LIGHT (YELLOW) F-FLASHER AL-ALARM LIGHT (RED) M3 M2 OVERLOAD ELEMENTS M2 M2 M2 BLK CIRCUIT BREAKER 208V, 230V - 15 AMP 460V - 15 AMP NOTE: DEPENDING ON PUMP MODEL, SEAL LEAK CIRCUIT MAY OR MAY NOT BE USED OR M1 M2 M3 1 WH/VIO WH/BRN 5 WH/BLK M1 WH/BLUE WH/BLK VIOLET 9 BLK BLK L1 L2 L3 INCOMING 3 PH 208V, 230V, 460V CAT. NO. CGL-23DW OR CGL-43DW 208, 230, OR 460 VOLT, 3 PHASE FLOAT CONTROLS MUST BE RATED FOR 2 AMPS AT 115 VOLTS NOTE: CONNECT ALL GREEN WIRES TO GROUND BAR R R 7 5 3 WH/YEL PUMP ON BLK HIGH WATER 1 AMP FUSE 1 AMP FUSE PUMP OFF AUTO OFF HAND 2 BLK M1 OVERLOAD ELEMENTS BLK 6 OVERRIDE OR OR OR RED ORANGE ORANGE M3 M2 POWER COR D PUMP 1 M1 RED WH BLK BRN WH PUMP OFF PUMP MOTOR PUMP ON RED CIRCUIT BREAKER 208V, 230V - 15 AMP 460V - 15 AMP WH BLK OVERRIDE 23 WH BLK HIGH WATER START WH BLK BRN RED WH BLK MAIN POWER COR D PUMP 2 MAIN BLK START 23833A150 11/08/12 STANDARD LIMITED WARRANTY Pentair Myers® warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Pentair Myers or 18 months from the manufacturing date, whichever occurs first – provided that such products are used in compliance with the requirements of the Pentair Myers catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids. During the warranty period and subject to the conditions set forth, Pentair Myers, at its discretion, will repair or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Myers reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for prior sold and/or shipped units. Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of startup through the Pentair Myers website: http://forms.pentairliterature.com/startupform/startupform.asp?type=m. Warranty is effective only if Pentair Myers authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Pentair Myers will cover only the lower seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Myers be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Myers service facility. This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Myers or an authorized Pentair Myers service provider; (h) to any unit that has been repaired using non factory specified/OEM parts. Warranty Exclusions: Pentair MYERS MAKES NO EXPRESS OR IMPLIED WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. Pentair MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE. Liability Limitation: IN NO EVENT SHALL Pentair MYERS BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY Pentair MYERS PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER INSTALLATION. Pentair MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS WARRANTY, FOR IMPROPER INSTALLATION. Pentair MYERS RECOMMENDS INSTALLATION BY PROFESSIONALS. Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or consequential damages and therefore such limitations may not apply to you. No warranties or representations at any time made by any representatives of Pentair Myers shall vary or expand the provision hereof. 1101 MYERS PARKWAY 490 Pinebush Road, Unit #4 ASHLAND, OHIO, USA 44805 CAMBRIDGE, ONTARIO, CANADA N1T 0A5 419-289-1144800-363-PUMP WWW.FEMYERS.COM Warranty Rev. 12/13