6 Commissioning 4085 Please ensure the “Benchmark” logbook is completed and left with the user. OVERHEAT SAFETY CUT-OFF 6.1 All Systems Commissioning should be carried out by a competent person in accordance with the current issue of BS6798. Do not operate the boiler wthout water. Make sure that the system has been thoroughly flushed out with cold water without the pump in place. Refit the pump, fill the system with water, making sure that all air is properly vented from the system and pump. Before operating the boiler check that all external controls are calling for heat. 6.2 Sealed Water Systems Only SETTING POINT Check the operation of the safety valve, by allowing the water pressure to rise until the valve opens. The valve should open within +/-0.3bar (+/-4.3lbf/in2) of the preset pressure. Where this is not possible conduct a manual check and test. CONTROL GAS SERVICE COCK THERMOSTAT (SHOWN OFF) KNOB Diagram 6.1 GAS PRESSURE ADJUSTMENT SCREW Release cold water to initial system design pressure. PLASTIC COVER 4108 Flush the whole of the system with cold water without the pump in place. Refit the pump and fill until the pressure gauge registers 2.7bar (40lbf/in2). Clear any air locks and check for water soundness. The set pointer on the pressure gauge should be set to coincide with the indicating pointer. MULTIFUNCTIONAL CONTROL 6.3 Initial Lighting and Testing CAUTION: This work must be carried out by a competent person, in accordance with the current issue of BS6798. Make sure that all naked lights and cigarettes are out. Identify the controls by reference to diagram 6.1. Check that the boiler is isolated from the electrical supply. Makes sure that the control thermostat is turned to “O” the “Off” position. Turn the gas service cock “On”, see diagram 6.1. Test the pilot supply tube and its connections for gas soundness as follows: Disconnect the ignition lead from the PCB, see diagram 5.9. Remove the combustion chamber front, see diagram 6.3. WARNING: The fan operates on mains voltage, terminals will become live. MAIN BURNER PRESSURE NOTE: TEST SCREW DO NOT ADJUST ANY Diagram 6.2 OTHER SETTING SCREWS Turn the electrical supply on and check that all remote controls are calling for heat. Check that the pump is circulating water through the system. To complete the test it is necessary to operate the boiler without its case, but UNDER ALL OTHER CIRCUMSTANCES the case must be correctly fitted and sealed. The step adjustment screw must not be touched. The pilot flame length should be as shown in diagram 6.4. Turn the control thermostat knob fully clockwise and the fan will work. Turn the control thermostat knob to “O” and isolate the boiler from the electrical supply. NOTE: There will be no sparks at the pilot. Take care and light the pilot with a match. Fit the combustion chamber front. Reconnect the ignition lead to the PCB. Test the pilot supply and connections for gas soundness, using a suitable leak detection fluid. Stick the self adhesive arrow indicator to the data label, against the rating that the boiler is going to be set to, for future reference. The arrow is in the loose items pack. Very cold weather may delay the operating sequence. The pilot rate is preset and must not be adjusted. 21 2000225233B