Download Monochrome Laser Printer Service Manual
Transcript
InfoPrint 1811, 1812 Dead machine service check CAUTION: Check the AC line voltage. The voltage should be within the following limits: • 100 V ac (volts alternating current)-127 V ac for the 110 V printer • 200 V ac-240 V ac for the 220 V printer FRU Action Unplug the printer. Remove the LVPS/HVPS, and check the fuses for continuity. LVPS/HVPS • If open, then replace the LVPS/HVPS. • If not open, then check the switch continuity across its conductors with the switch on. Turn the switch off. Plug the AC line into the LVPS/HVPS and switch unit on. Note: Voltages are exposed at several places on the board. Do these verifications, and then unplug the AC cord from the power supply: Pins Voltage CN201-6, 17, 19 +24 V dc CN201-10, 12, 14, 16, 18 Ground CN201-1,3, 5, 11,13, 15 +5 V dc • If voltages are not correct, then replace the LVPS/HVPS. • If voltages are correct, then check the controller board. See “Controller board service check” on page 2-18. 2-20 Lexmark™ E360d, E360dn