Machine Action
The broiler is designed and rated for operating conditions where the temperature is above 32F
Below 32F the actuator and upper platen may have higher friction and this results in slowed or sticky motion and overcurrent
errors (alarms 6 and 2)
The motor and all grates must warm up for the unit to function
An incorrect high temperature alarm message may be displayed: instead of reporting that the temperature is below 32F it
will report a high temperature alarm (alarms 21-24)
If any alarm from 21-24 is seen, the user should press the thermometer button to see the reported temperatures. All zones
must be above 32F before the alarm clears.
Reported grate temperatures may be lower than expected due to offsets; grill start-up may be delayed as a result (unless the
store warms the grates through some other means)
If an alarm was seen on start-up, the unit may not have finished its homing sequence: if the Press & Go button is greyed out,
turn the power off for 20 seconds then restart
Notes associated with event number.
Self-detected SIB error
Any
Hardware Problem
self-detected on
SIB
31
Any
Lane Communica- Defective circuit on UI or SIB; Brotion or Internal
ken wire; Electrically noisy enviroProgrammatic Error ment
Defective circuit on SIB; Memory
and/or software corruption on SIB
SIB unable to communicate
with UI
The LRS is not seen during calibration.
Lower Reference
Switch Failure
30
“Event
Index”
25
Event Suffix
(If Applicable)
Temperature
Motion
24
See cause statement
Error generation criteria
After finding the URS, the
During
platen moves the maximum
cold
allowed stroke of 2.900
home or
inches for safe operation
hot home
without finding the LRS
State
Any
Event Cause
Sensor detecting
Thermocouple is reading a temtemperature in
perature >685 F at some point
excess of High Temother than during a cook cycle
perature - Lower IR
Event Group
System
System
Event Description
GARLAND ELECTRIC CLAMSHELL BROILER GRILL, CXBE12 MODEL
SERVICE MANUAL
DIAGNOSTICS EVENTS LIST, continuation
Page 63