Download PRODUCT MANUAL INSTALLATION, OPERATION
Transcript
Part: G_EB_SM_CFABROILER Rev 09 (7 Mar 14) • • • • • • • “Reverse and move to Hood Height position if possible; Heaters: ALL are OFF Wait for operator input” “Reverse and move to Hood Height position if possible; Heaters: ALL are OFF Wait for operator input” “Reverse and move to Hood Height position if possible; Heaters: ALL are OFF Wait for operator input” “Reverse and move to Hood Height position if possible; Heaters: ALL are OFF Wait for operator input” Machine Action The broiler is designed and rated for operating conditions where the temperature is above 32F Below 32F the actuator and upper platen may have higher friction and this results in slowed or sticky motion and overcurrent errors (alarms 6 and 2) The motor and all grates must warm up for the unit to function An incorrect high temperature alarm message may be displayed: instead of reporting that the temperature is below 32F it will report a high temperature alarm (alarms 21-24) If any alarm from 21-24 is seen, the user should press the thermometer button to see the reported temperatures. All zones must be above 32F before the alarm clears. Reported grate temperatures may be lower than expected due to offsets; grill start-up may be delayed as a result (unless the store warms the grates through some other means) If an alarm was seen on start-up, the unit may not have finished its homing sequence: if the Press & Go button is greyed out, turn the power off for 20 seconds then restart Notes associated with event number. Self-detected SIB error Any Hardware Problem self-detected on SIB 31 Any Lane Communica- Defective circuit on UI or SIB; Brotion or Internal ken wire; Electrically noisy enviroProgrammatic Error ment Defective circuit on SIB; Memory and/or software corruption on SIB SIB unable to communicate with UI The LRS is not seen during calibration. Lower Reference Switch Failure 30 “Event Index” 25 Event Suffix (If Applicable) Temperature Motion 24 See cause statement Error generation criteria After finding the URS, the During platen moves the maximum cold allowed stroke of 2.900 home or inches for safe operation hot home without finding the LRS State Any Event Cause Sensor detecting Thermocouple is reading a temtemperature in perature >685 F at some point excess of High Temother than during a cook cycle perature - Lower IR Event Group System System Event Description GARLAND ELECTRIC CLAMSHELL BROILER GRILL, CXBE12 MODEL SERVICE MANUAL DIAGNOSTICS EVENTS LIST, continuation Page 63