11400-Series
Digltlzing Oscilloscopes
~
GPIB
IEEE-488
.
The 11400 Series complies
with IEEE
Standard 488.1978. RS.232C. and with
Tektronix Standard Codes and F1:Jrmats.
1-GHz and 500-MHz Bandwidth
. Eight Channels of Display and
Acquisition
. Plug-ln Modularity
. Waveform Processing and Automatic
Pulse Parameters
. Multiple 10,240-Point Waveform
Records
. Accepts Differential, HighImpedance, and 50-!l-lnput
Amplifiers
. Greatly Simplified Access to
Features
. Fully Programmable via GPIB and
RS-232C
With compliments.doc
TYPICALAPPLICATIONS
WaveformCharacterizatlon
Prototype Troubleshooting
and Debugging
MeasurementAgainst a Standard
The 11401and 11402are the first in a new
line of digitizing oscilloscopes. These versatile scopes,with their array of new supporting plug-ins and probes, solve
measurement problems equally weil on a
designer's bench or in a programmable
test system. Digital designers will benefit
from flexible triggering features and an
eight-channel display. Analog and powersupply designers can apply extensive
waveform processing to signals acquired
through high-performance differential
and single-ended amplifiers. 11000-Series
digitizing scopes can follow your designs
production. Full programmability via
. into
either IEEE-4BB or Rs-232C and features
77&e
11401 und 11402 are the first in a li'ne of high bandwidth, programmable digitizi1lg
like a DMA controller für fast waveform
IJSCiUosco-pes.
The 11401111402are idealfor digitizi1lg und accurately measuri1lg repetitive
transfers make these scopes a perfect fit
~veforms. 10-14 bit tleTtical resolution, 20 MSisA/D conversion system provides a cost-effective
für systems. 11000-Seriesdigitizing oscillosolution to a wide range of measurement problems.
scopesset new standards in performance.
Live Display 01 Up to Eight Traces
The 11401/11402 each support three
vertical-amplifier pluS-ins. This means
you can acquire up to eight channels of
data at 300 MHz, up to six channels of
data at 600 MHz, or up to three channels
of data at 1 GHz. You can, of course, mix
and match the pluS-ins to design the
system that works best für you. Eight
traces can be displayed at any one time
so that you can get the whole picture on
one screen. The update rate is so fast that
the 11401 and 11402 have the look and
feel of analog scopes.
T
E
K
1 GHz and 500 MHz
DIGITIZING OSCILLOSCOPES
.
c,
..
'"
-
-"
..
-
.
-
I
11000
SERIES
menus present choices and Cold down
when those selections are made. Onebutton hard-copy generation is made
possible by the use of a standard Centronix port and software drivers compatihle with Thktronix 4644 and low-cost Epgon dot-matrix printers. Overall, the
operation of the 11401/11402is intuitive.
The instrument can be used easily even
if it is not used every day. Acquisition
measurement, and documentation is ~
simple as six touches: Auto-set, mea..,ure,
measurements, rise, exit, hard copy. lt
doesn't set any simpler.
Plug-ln Modularity
The 11401and 11402are compatible with
five different vertical amplifiers. Each
scope will accept three of these amplifiern
in its plug-in compartments. You can configure a scope to meet your particular
needs, für example:
. Timing Measurements on High-Speed
TlI~ 11402 Digitizing
Logic
Use three 11A71sin the 11402für three
I-GHz bandwidth channels.
Osc'iUlJS{'ape
'Ivith 1-GHz System banduJidth.
High Vertical and Horizontal Resolution
The 11401 and 11402 uniquely combine
wide bandwidth with 10-ps horizontal
resolution and 10-bit vertical resolution
(vertical resolution can be increased to 14
bits when signals are averaged). Other
vendors have made a tradeoff: bandwidth
für vertical resolution or vertical resolution für bandwidth. The 11401/"11402
give
you both für making demanding voltage
and timing measurements in Olle box. In
addition, the 11401l'11402'strigger-totrigger measurement feature delivers
200-ps precision on single-shot time A - B
measurements and can even pro\ide
10-ps precision with averaging. lliggerto-trigger measurements of this nature
are only available on the 11401/11402and
a fev.' expensive, standalone counter!
Versatility tor a Wide Range of
Applications
. Characterization
Lab
of Waveforms
in a
Five plug-ins and new probes bring outSelect an 11A52 for two highstanding versatility to the 11401/11402.
bandwidth 50-0 channels, an 11A33for
The measurement-system and waveformhigh-bandwidth differential measureprocessing functions lead to quick soluments, and an 11A34 for four hightions to a wide variety of voltage, time,
impedance channels.
area and energy problems. The I-GHz
. Prototype
Troubleshooting
and
11402 can process and measure signals
Debugging
from high-bandwidth 50-ü amplifiers,
Use two each, four-channel amplifiers
high-impedance amplifiers, and differenand a two-channel high-bandwidth
tial amplifiers. I-mV sensitivity and 500-V
amplifier. This configuration gives you
maximum input voltage let users capture
eight channels of acquisition for timing
small signals from transducers or monitor
analysis and two high-bandwidth
ac power lines. Fast overdrive recovery
channels for exacting pulse response
and up to 2000 divisions of dynamic range
measurements.
give these scopes the power to look at
Power-Supply Evaluation
even the smallest detail on difficult-toUse three differential amplifiers to
capture waveforms.
determine efficiency and stability and
timers.Also, wind.owrecordscan ?e used Unparalleled Ease of Use
to measure noise and ripple.
to mcrease honzontal resolutIon on The 11401and 11402usesimple parallel . DAC and Operational-Amplifier
Set.specific segments of main records to pro- menus and touch screen to give easy actling
Time
vide a clear picture of signal details.
cess to their measurement and display
Fast overdrive recoverj' and up to 14
Multiple Long Record Lengths
features.All but.a few of the buttons and
bits of resolution make possible settlingThe 11401111402can acquire multiple
knobs have been eliminated in favor of
time measurements to ~-ithin a fraction
records of up to 10,240 points each. No a system that anly presents selections
of apercent.
other scope can capture as much data at. when they are valid and/or useful. An
once on repetitive waveforms. The main- autoset function sets up the scope tor you The Most Accurate Instruments 01 Their
Kind
trames can contain up to 102,400 points based upon the signal characteristics of
of waveform memory with Option 2D. the selected trace. This function can be The 11401 and 11402 are the most aCcurate high-bandwidth scopes on the
Long records and large storage capacity
activated from the probe tip, allowing für
market. They carotine the timing accambine to let users gather data over hands-off operation of the scope. Autoset
curacy inherent in digital time bases~;th
relatively long periods of time with high frees the operator to concentrate on the
resolution and improve measurement ac- measurement problem and the probe con- 1% vertical accuracy. The Enhanced AccuraC)' feature prompts the user to start
curacy. Olle doesn't need a computer to nection. The most. commonly used funcroutines whenever
log waveform data. Waveforms can be tions are no deeper than a second menu self-calibration
temperature
or
configuration
changes
stored on-board the scope für later level. lcons let you assign the knobs to
warrant it. You can even assign the
analysis.
waveform size and position no matter
11401/11402 to start a self-calibration
what operating mode you are in. Pop-up automatically. Time-base accuracy is
~
.
The11401and 11402 can display up to eight
tracesJ"roma variety of sources.Displayeight
channe/sof live u-aveformsfar timing analysi.S'
on digital systems, Oy display combinatiorl.S
Q/tive and stoyed u!avejorms.
,Wultiple wavejarm-parameter measurements
can beperf()nMd anti areupdatiJd continumiSly. A compare-and-reference measurement
mode aUows measurement results to be compared 10a standard, and ehedifference of two
results to be displayed.
Two buill-in time bases provide the !unetionality of delaying and delayed sweep.sin
analog scopes.The main time ba.sedejines ehe
overall acquisition i,nterval and the window
time ba.seallows high-resolution acquisition
of small portions of complex waveforms.
probes with this new interface is ready
to assist in the solution to your measurement problems.
Choose Your Computer Interface
The 11401and 11402have both IEEE-488
and RS-232C interfaces as standard
features for data transfer and instrument
control. The RS-232C port lets you conOn-Site Serviceability
trol the instrument with a PC, upload or
These scopes are card modular; they have
download waveforms from a workstation
extensive self-test and diagnostic routines
or mainframe, or run diagnostics over a
andreliability built-m. On-site Warrantymodem. GPffi and RS-232Cmenus let you
Plu.5service options help you keep the inmatch interface parameters with a construments up and running when down
troller, modem, or hast. If speed is a contime might otherwise halt Jour producsideration, the parallel interface provided
tion line. Tektronix service technicians
by the IEEE-488 port should be used. A
can be at Jour facility repairing these OMA option can be added to speed up
products within eight working hours if
GPIB data transfers even further.
youare within 75 miles of designated U.S. Whichever bus is chosen, the instruments
service centers.
respond to a logical set of Tektronix
Standard Codesand Formats commands
Probe Interface
that make it easy to write your test
We'veset a new standard for probe interfacing. Signal and probe-power connec- procedures.
tions are all made at the amplifier input,
Accurate, Automatic Measurements
eliminating extra probe-power lines. We The only reason oscilloscopes exist is für
cansupport as many active probes as you making measurements. The 11401 and
have channels. A smart serial interface
11402 perform waveform-processing
hetweenthe probe and the scope lets you functions, pulse-parameter analysis, curstop worrying about the proper terminasor functions, and trigger-to-trigger
tion impedance; it is set automatically.
measurements that combine to cover a
Youcan autoset the scope or sequence full range of measurement needs. A
through a genes of front-panel set-ups all special annotation mode shows where
from the probe-rn button. This leaves measurements are being made on the
Yourhands free to probe your circuit. A trace so users can feel confident that they
full complement of active and passive are on target. Oot cursors can be split
between two waveforms to make pro pagation-delay measurements or compare
voltages. Measurement zones can be set
to limit the automatic measurement to a
portion of a displayed trace. Users can set
proximal, distal, and mesial levels to
customize timing measurements. Up to
six measurement results can be displayed
and continuously updated as the data
changes.This lets users make adjustments
and see the results quicker than ever
before. A direct hard-copy output is provided that includes time and date of the
measurement tor archiving.
A Measurable Advance in Oscilloscope
Technology
Higher bandwidths, better resolution,
more accuracy, more versatility, hardware
and software modular, easier to use and
service, the 11000 Series sets new standards for digitizing oscilloscopes.
100ps +0.002% of the measured time interva1.The 11401 and 11402's accurate,
automatic measurements can rep1ace
dedicated countedtimers
and ac
voltmeters. Devices and subassemb1ies
can be tested to tighter tolerances, improving end product performance and
quality.
CHARACTERISTICS
VERTICAL SYSTEM
Enhanced AccuracyDepends on plug-in unit.
Equivalent-Time Bandwidth-Depends
on
plug-in used. (SeeMaximum Bandwidth Matrix
in the IIOOO-SeriesReference section.)
Vertical Resolution-IO
bits (1024 levels.)
Resolution can be increased to 14 bit., (16384
levels) using signal averaging.
Accuracy
With
TE K
1 GHz end 500 MHz
DIGITIZING
OSCILLOSCOPES
1100()
-.'"
,,~c
'
";,.
~ ,.
High bandwidth allows capture and measurement Qf.fast ri.~ limes Measu~
can be:
ruSlomized a'ld annotated to clearly shou'
wherf' artd hau' the measurement is being
~.
A
HORIZONTAL SYSTEM
Time Bases-Two identical built-\n time b8ses.
Record Duration-5.12 ns to 1024 s in 1-2-5
sequence
Time.Base Accuracy-IOO ps ...0.002% of
measurement inten"a1.
Record Length-512 points to 10,240 points.
Sampling Rate-20 MSis maximum.
Main Record Positioning-Position
of the
main record with respect to tht! trigger point
of the maul record. Prerrlgger: 1 record duration. fusTtrigger: I record duration. Resolution:
I maiß record point.
Windows-ln
addition to the main record,
either one or two window records may be acquired and dispiayed The windo,,' record~ may
be of a different Jength (duration) and may
have a smaller lulleidiv than the maiß record.
Ir t".o "'indo\\" rerords are used, they have the
samt! duration and timt!idiv settings and can
be [JOsitioned independently.
Windo,,' Record Positioning-The
windo\\"
record!Oare ~I~tioned relative to a windo""
trigger point, which may be positioned relative
to the main record's tngger point delayed by
either time or E'vents.
Main-Window
nme Measurement-The
time bet""een the MAIN record trigger and the
WINDOW trigger can be measured precisely,
eVE'n if each trigger occu~ only once.
Repetitive events allow this measurement to
be averaged for better resolution and accu~.
Single Trigger Precision: 200 ps. Repetitive
Precision: 10 ps, after 100 averages.Accuracy:
250 ps ...0.002% of record duration.
Coupllng and SensitivityDC Coupled: 0.35 div from dc to 50 MHz, increasing to 1 div at 500 MHz.
Noise Reject Coupled: 1.2 div or less from dc
to 50 MHz, increasing to 3 div at 500 MHz.
AC Coupled: 0.35 div from 60 Hz to 50 MHz
increasing to 1 div at SO()MHz. Attenuates
signals belo,,' 50 Hz.
HF Reject Coupled: 0.5 div from dc to 30 kHz.
LF Reject Coupled: 0.5 div from 80 kHz to 50
MHz, increasing to 1 div at. 500 MHz.
HoldotC Range-500 ns to 10 s.
TRIGGERING SYSTEM
Range-:!: Full screen.
Band,,'idth-500
MHz maximum.
Di~~~
high-resolution
Accumulaie
ing makes
display
with
Poinl-
Mode a/.(mg with powerful
tn:ggerit mudl
6OSi6r to ca.ptuf'P
and
d~lay
common
m6t.a8t4ble ~
digital{ault
conditions
like
glücJI-.
and nIce oondition&
MEASUREMENTSYSTEM
Waveform-Processing Functions-Waveform
Functions: Differentiale, in~U!,
interpolate,
smooth, average, and envelope, Arithmetic
Operators: Plus. minus, multiply, divide, square
root, logn, absolute value, signum, exp.
Measurement
Set-Amplitude
Measurements: Min, max, mid mean, peak-peak, RMS.
Timing Measurements: Rise, fall, width, delay
I, main-windo\\', period, propagation delay,
and freQuenC)'.Area and Energy: Area +, Area
.
: '. ,;".'
;
.,. I
SERIES
AJwerful wa~form-PnJceSsing functioM leI
v.sersdJUtIRtraces such os the power wa~orm
shown a~
77w top wavfd"orm is a VOLtage
waV!!form and the /x}ttom ~
is a 1KJWer
waV(lform created by squaring the VOltag~
waVfd'onnand dividing it by a lood ~71«
or paired mode,horizontal and vertical bars,
measurement-wnedelimiters.
CRT AND DISPLAY FEATURES
Standard CRT-9 in diagonal, monochrome,
magnetit deflection. Vertical raster-scan
orientation.
Standard Phosphor-GH (P31).
Video Resolution-552 horizontal by 704 vertical di!'played pixels.
POWER REQUIREMENTS
Line-Voltage Ranges-90 to 132 V RMS. ISO
to 250 V RMS
Line Frequency-48
t() 440 Hz.
Maximum Power Consumption-320 W.
ENVIRONMENTAL
AND SAFETY
Temperature-Operating:
0 to +50OC. Nonoperating: -40 to + 75 OC.
Humidity-Operating
and Nonoperating: Up
to 95% relativ~ humidity, up to +50OC.
Altitude,
Vibration,
Shock,
Bench Handling-Meets
MIL-T-28800c, Type 111,Class 5.
- , energy.Cursors:Single or dual dots, split
~ ~
to dot-~trix
- prinUrs
is provided througha standard CenlnmicsJIOTt.
H4m copi& 4re time 4nd d4lestampedfor4'fChivi1lg.
11
I
11Ie 11401and 11402 oller a unique combination of accurate timing
and accurate
amplitude measurements in a7lei1lStru1'nent.
Sirlgle or duallOxlD-division ~S may be
brought up Jor waV(lfarm displa:!J; Each axis
Electromagnetic Compatibillty-Meet.5 MILT.28800C;MlL-&TD-461B; FCC Part 15,Subpan
J, ClassB; VDE 08iV6. i8 Class B; CE-O1Part
4, with exceptions; CE-O3 Part 4, Curve 1;
CE-O:3
Part 4, Curve 4, Navy, NB, BB (with exceptions); CS-O1Part 7; CS-O2Part 4 (with exceptions);CS-06 Part 5; RE-O1Part 4 (with exceptions); RE-O2 Part 4; RS-O1Part 4; RS-Q3
?art i (limited to 1 GHz).
Safety-Listed UL 1244; CSA Bulletin 556B,
September1973;Thktronix self-certification to
Option lR-Rackmount.
Includes: Hardware,tooling,and instructions tor converting bench
model to rackmount configuration.
Option 2D-Memory Expansion.
Expandstotal waveform memoryto
102,400 points tor storage of
waveform records.
Option 4D-DMA Controller. Increases data transfer speed over
complywith lEC 348 recommendations.
PHYSICAL
-
CHARACTERISTICS
Cablnet
-
Dimensions
Width
Helght
Depth
-
Weights
-~
~
Net
St1lpplng
~-
-
Rackmount
mm
in.
mm
in.
448
176
483
190
238
599
94
23.6
222
550
8.8
21 6
kg
-
19
280
Ib
416
62.0
kg
-
Ib
220
31 4
48.0
68.0
ORDERING INFORMATION
11401 :)OO-MHz Programmable
Digitizing Oscilloscope
Includes:
Operator
guide (070-6103-00);
operator reference (070-5i91-00);
power cord
(161-0066-00); incoming inspection
(070'6694-00).
~1402 I-GHz Programmable
19ltlzing Oscilloscope
Ihcludes: Same as 11401.
OPTIONS
OPtion tC-Gable Feedthroughs.
Adds eight rear-to-front
feedIbroughs.
procedure
representsaJulllO-bit digitizirlg window.
GPIB.
INTERNATIONAL POWER PLUG OPTIONS
Option Al-Universal
Euro 220 V, 50 Hz.
Option A2-UK 240 V, 50 Hz.
Option A3-Australian
240 V. 50 Hz.
Option A4-North American 250 V, 60 Hz.
Option A5-Switzerland
240 V, 50 Hz.
WARRANTY-PLUS SERVICE PLANS
SeeCustomer Services and Information section
in the back of this catalog.
80-0n-Site Product Installation and
Set-Up.
81-(11401) 1 Year On-Site Service.
81-( 11402) I Year On-Site Service.
OPTIONAL ACCESSORIES
Power-Supply Extended Diagnostics.
Order 067-1264-00
Service Manual-Order
070-6779-00.1
Camera-C-4 Option 10
Cables(GPIB) 2 m. Order 012-0991-00
(RS-232C) 10 ft. Order 012-0911-00
(Centronics) 10 ft for hard copy
output. Order 012-0555-00
Blank Panel-For empty
compartrnents. Order 016-0829-00
The 11401and 11402are eMily integrated into automated test systems. Options foT rock
c{)nvers'ion, rear-w-front signal routing, and
DMA tra1l.${erofwat'eform data and measurement results maU ehe 11401/11402idealfar
systems applications.
Extender BoardOrder 067-1267-00,'1
Hard Copy Unit-Tektronix
4644
Dot Matrix Printer
Recommended Probes-See recommended probes later in this section,
Recommended Cart-K217, SeeInstrumentJCart Compatibility chart in
the Accessories section,
'I
Toarder, CO1!lact
yaur kxal TektronixSales
Office,
SOFTWARE SUPPORT
11400-Series/IBM PC UtilltyWavefomlJmeasurement data logging, graphics, and statistical
analysis. GPIB and RS-232Csupport.
Order S47PIO2.
11400-Series Asyst DriverMenu-driven package für scope control, wavefoml acquisition, data logging, and FFT analysis. Order
S47P:303
For more infomlation on utility and application software, see System Support section or
consult your local sales or applications
engineer.
TRAINING
Tektronix Instrument Group Customer Training otters operation and application training
to help you get tu" value out ot your Instrumentation investment. See Customer
Training section tor information or
1-800-835-9433ext. 430. In Oregon,
1.629-1017(collect).
ca"
ca"