Commercial Air Conditioning SERVICE MANUAL Models AU242FHBIA AU482FIBIA AU48NFIBJA And its indoor units zFeatures zNew cassette unit, with 700*700 panel and new unit body zNew PCB for cassette indoor unit and outdoor unit, much stabler zMutiple indoor unit types: cassette type, ceiling concealed type, and wall mounted type zFree combination, total indoor capacity can be 50%~130% of outdoor capacity zMultiple control types, infrared control+wired control zIndividual operation for every indoor uint, energy saving zNew refrigerant control device: MP2A, MP3A zAuto restart function zLong piping and high drop between indoor and outdoor zRefrigerant: R407C Manual code: SYJS-017-05REV.0 Edition: 2005-11-22 Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA CONTENTS Contents………………………………………………………...2 1. Description of products & features………………………..3 2. Specification…………………………………………………6 3. Safety precaution…………………………………………...14 4. Net dimension……………………………………………….16 5. Installation instructions………..……………………………21 6. Parts and functions………………………………………….53 7. Controller functions.............………………………………..21 8. Electrical control functions…………………………………71 9. Wiring diagrams…………………………………………….95 10. Failure code and troubleshooting………………………..99 11. Noise level……………………………………...................121 12. Performance curves......................................................124 -2- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 1.DESCRIPTION OF PRODUCTS & FEATURES 1.1. Products code explanation A B 14 2 F C B I A Climate type: T1 (see table 1) Design number (I stands for design sequence, inverter frequency type) Product type: A stands for heat pump type, refrigerant is R22 B stands for heat pump type, refrigerant is R407C M stands for cool only type, refrigerant is R22 N stands for cool only type, refrigerant is R407C Appearance code Product series: F stands for MRV Applicable voltage: 2 stands for 220-230V/50Hz, 4 stands for 220V/60HzˈN stand for 380-400V/50Hz Cooling / Heating capacity,14=14000BTU/h Product type : “B” stands for cassette type, “C” stands for convertible type, ”D” stands for duct, “S” stands for split type, ”Q” stands for chiller system, "E" stands for ceiling concealed type, “U” stands for outdoor unit Air Conditioner 1.2 Brief Introduction for T1ǃT2ǃT3 working condition Climate type Type of Conditioner Air T1 T2 T3 Cooling Only 18 ć~43ć 10ć~35ć 21ć~52ć Heat pump -7ć~43ć -7ć~35ć -7ć~52ć Electricity Heating ~43ć ~35ć ~52ć 1.3 Operating Range of Air Conditioners Working temperature range Cooling Indoor outdoor Heating Indoor outdoor Rated Maximum Minimum DBć 27 32 18 WBć 19 23 14 DBć 35 43 -5 WBć 24 26 -- DBć 20 27 15 WBć 14.5 -- -- DBć 7 24 -15 WBć 6 18 -- -3- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 1.4 Product features New designed panel 700*700 with the 600*600 cassette unit New designed swing louver with the non smooth surface, which can hold back the condensant water. New designed filter lock, which will fix the filter more firmly than before. Adopts the stepping motor, give the louver a larger swing angel. New fan with bigger diameter fan blade, sending out larger air flow. The cassette indoor unit adopts the panel whose dimension is identical to that of ceiling, after installation, the unit will be accordant with the decoration decor. Free combination, total indoor capacity can be 50%~130% of that of outdoor capacity The outdoor unit can match with all types of indoor unit with the allowable capacity, such as the cassette type, the ceiling concealed type, the wall mounted type, etc. Optional control types: infrared remote controller and wired controller The unit can be controlled by the smart infrared remote controller YR-H71, which can realize many functions such as heating, cooling, fan, swing, fresh, health, filter up/down, electric heating, etc. Furthermore, the remote controller can be compatible with many old controllers, more convenient for utilizing. If the unit is with wired controller YR-E06, which can realize remote control type by adding an infrared controller YR-H71. Auto-check function The unit can display the malfunction codes on the control board by using advanced auto-check technology, convenient for user find and dwell with the abnormal running. Auto–restart function (optional) All indoor units have auto-restart function. When the power supply cut off suddenly, the unit will automatically recover the previous running mode once the power supply is on. New refrigerant control device: MP2A, MP3A The new refrigerant control device MP2A and MP3A replace the previous device MP2 and MP3. The new device includes gas pipe and liquid pipe, more convenient for installation than before. -4- Commercial Air Conditioner Total unit: outdoor units appearance model refrigerant AU242FHBIA R407C AU482FIBIA AU48NFIBJA R407C appearance model indoor units type AB092FCBIA Four way cassette AB142FCBIA AB182FCBIA AE072FCBKA AE092FCBKA AE122FCBKA Ceiling concealed AE142FCBKA AE182FCBKA AE242FCBKA AS072FCBHA AS092FCBHA Wall-mounted (colorful screen) AS122FCBHA AS142FCBHA AS182FCBHA -5- Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 2. SPECIFICATION AU242FHBIA Item Model Function AU242FHBIA cooling heating Capacity BTU/h 24000 27000 Capacity W 7030 7910 Total power input W 3200 3100 Max. power input W 3800 3800 W/W 2.2 EER or COP 2.55 2 Power cable 6mm NˈVˈHz 1PH,220-230V~,50Hz A/A cooling: 18A/21A heating: 17/21A Start Current A -- Working frequency range Hz 30-105 Fuse A 3.15A 250V AC Power source Running /Max.Running current AU242FHBIA (white) Unit model (color) Type ROTARY Type × Number AXIAL*1 r/min 840±30/780±30/550±50 Fan motor output power kW 60*1 Air-flow(H-M-L) m³/h 3240 Type / Diameter mm inner grooved copper pipe ¶9.52 Speed Fan Outdoor unit C-7RB267H03AA/ SANYO SHENYANG Model / Manufacture Compressor Heat exchanger Temp. scope Dimension 2*1.5mm Row*fin pintch ć External ˄L×W×H˅ mm×mm×mm 948X830X340 Package ˄L×W×H˅ mm×mm×mm 1050X979X440 Refrigerant control method mm/mm Volume of Accumulator Noise level L -- dB(A) 58 -- material of reduce noise W 30 kg / kg 74/89 g R407C/3200 Recharge quantity g/m ij9.52 liquid pipe: 65g/mhactual length Liquid mm ¶9.52 Gas mm ¶15.88 crankcase heater power (Net / Shipping) Refrigerant PIPING EEV AUTO Defrosting Weight -- Pipe Type / Charge flared Connecting Method Between I.D &O.D MAX.Drop m outdoor upper: 30, outdoor lower: 20 MAX.Piping length m 50 -6- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA AU482FIBIA Item Model Function Capacity Capacity Total power input Max. power input EER or COP Power cable Power source Running /Max.Running current BTU/h W W W W/W PIPING heating 48000 61000 14000 18000 6500 6000 7500 7500 2.15 3.00 16mm NˈVˈHz A/A A Hz A Outdoor unit Type / Charge Recharge quantity Liquid Pipe Gas Connecting Method MAX.Drop Between I.D &O.D MAX.Piping length Refrigerant cooling 2 Start Current Working frequency range Fuse Unit model (color) Model / Manufacture Compressor Type Type × Number Speed r/min Fan Fan motor output power kW Air-flow(H-M-L) m³/h Type / Diameter mm Heat exchanger Row*fin pintch Temp. scope ć External ˄L×W×H˅ mm×mm×mm Dimension Package ˄L×W×H˅ mm×mm×mm Refrigerant control method mm/mm Defrosting Volume of Accumulator Noise level material of reduce noise crankcase heater power Weight (Net / Shipping) AU482FIBIA L dB(A) W kg / kg g g/m mm mm 1PH,220-230V~,50Hz cooling: 34A/42A heating: 30/40A -30-105 3.15A 250V AC AU482FIBIA (white) EEV48FAL1/MITSUBISHI ELECTRIC SCROLL AXIAL*2 920±30r/min/840±40r/min/560±50r/min 65*2 7480 inner grooved copper pipe ¶9.52 2*1.5mm 43-60 1250X948X340 1375X1050X440 EEV AUTO -58 -40 120/135 R407C/4200 ij9.52 liquid pipe: 65g/mhactual length ¶9.52 ¶19.05 flared m m -7- outdoor upper: 30, outdoor lower: 20 100 Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA AU48NFIBJA Item Model Function Capacity Capacity Total power input Max. power input EER or COP AU48NFIBJA cooling heating BTU/h 48000 61000 W 14000 18000 W 6000 6000 W 7000 7000 W/W 2.33 3.00 4mm2 Power cable Power source Running /Max.Running current NˈVˈHz A/A 3N~,380-400V,50Hz cooling: 10.5A/13A heating: 10.5/13A A -- Working frequency range Hz 25-95 Fuse A 3.15A 250V AC Start Current AU48NFIBJA (white) Unit model (color) Compressor AEV60FCHMT/MITSUBISHI ELECTRIC Model / Manufacture SCROLL Type AXIAL*2 Type × Number Outdoor unit Fan Heat exchanger r/min 920±30 r/min/840±40r/min/560±50r/min Fan motor output power kW 65*2 Air-flow(H-M-L) m³/h 7480 Type / Diameter mm inner grooved copper pipe ¶9.52 Speed Temp. scope Dimension 43-60 ć External ˄L×W×H˅ mm×mm×mm 1250X948X340 Package ˄L×W×H˅ mm×mm×mm mm/mm 1375X1050X440 Refrigerant control method Defrosting EEV AUTO L -- dB(A) 58 material of reduce noise -- crankcase heater power Weight (Net / Shipping) Volume of Accumulator Noise level Refrigerant PIPING 2*1.5mm Row*fin pintch Pipe W 40 kg / kg 120/135 g R407C/4400 Recharge quantity g/m ij9.52 liquid pipe: 65g/mhactual length Liquid mm ¶9.52 Gas mm ¶19.05 Type / Charge flared Connecting Method Between I.D &O.D MAX.Drop m outdoor upper: 30, outdoor lower: 20 MAX.Piping length m 100 -8- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Indoor: Item Cooling capacity Heating capacity Cooling capacity Heating capacity Dehumidifying capacity Power source Running current Starting current Refrigerant Noise level(H/M/L) model Btu/h Btu/h W W 10ϋ³×m³/h NˈVˈHz A A dB(A) Type × Number Air-flow(H-M-L) Fan motor output starting mothod Fan Heat exchanger Refrigerant control method Dimension(L×W×H) External Shipping Panel dimension (L×W× External H) Shipping Net Weight(unit/panel) Shipping Liquid Piping Gas Connection method Suited area Controller type Item m³/h W mm×mm×mm mm×mm×mm mm×mm×mm mm×mm×mm kg / kg kg / kg mm (inch) mm (inch) m2 model Cooling capacity Heating capacity Cooling capacity Heating capacity Dehumidifying capacity Power source Running current Starting current Refrigerant Noise level(H/M/L) Btu/h Btu/h W W 10ϋ³×m³/h NˈVˈHz A A dB(A) Type × Number Air-flow(H-M-L) Fan motor output starting mothod Fan m³/h W Heat exchanger AB092FCBIA AB142FCBIA 9000 12000 11000 14000 2800 3600 3200 4000 1.6 2.1 1PH 220V-230V~ 50HZ 1PH 220V-230V~ 50HZ --1 1 R407C R407C 42/--/-42/--/-centrifugal fan×1 centrifugal fan×1 700/--/-700/--/-55 55 PG PG Combination of wave cranny radiation fin and copper Capillary + EEV 660×570×260 660×570×260 710×675×360 710×675×360 700×700×60 700×700×60 740×735×105 740×735×105 19.0/2.8 19.0/2.8 23.5/4.8 23.5/4.8 6.35 (1/4") 6.35 (1/4") 12.7 (1/2") 12.7 (1/2") flared flared 12~23 17~27 remote controller AB182FCBIA 17000 19000 5000 5500 2.1 1PH 220V-230V~ 50HZ -1 R407C 42/--/-centrifugal fan×1 700/--/-55 PG Combination of wave cranny radiation fin and copper pipe Refrigerant control method Dimension(L×W×H) External mm×mm×mm Capillary + EEV 660×570×260 Shipping mm×mm×mm 710×675×360 External mm×mm×mm 700×700×60 Shipping mm×mm×mm 740×735×105 Net kg / kg 19.0/2.8 Shipping kg / kg 23.5/4.8 Liquid mm (inch) 6.35 (1/4") Gas mm (inch) 12.7 (1/2") m2 22~33 Panel dimension (L×W× H) Weight(unit/panel) Piping flared Connection method Suited area Controller type remote controller -9- Commercial Air Conditioner Item model Cooling capacity Heating capacity Dehumidifying capacity Power source AE072FCBKA Btu/h 7000 Btu/h 9000 10ϋ³×m³/h 1.2 NˈVˈHz 1PH 220V-230V 50HZ Refrigerant Noise level(H/M/L) dB(A) Type × Number Air-flow(H-M-L) m³/h starting mothod Fan Heat exchanger Refrigerant control method Dimension ˄L×W×H˅ External Net Weight Liquid Gas Piping kg mm mm m2 flared 8~16 Item Cooling capacity model Btu/h AE122FCBKA 12000 Heating capacity Dehumidifying capacity Btu/h Connection method Suited area Controller type NˈVˈHz 1PH 220V-230V 50HZ R407C dB(A) 42/38/32 Type × Number centrifugal fan×2 Fan Air-flow(H-M-L) m³/h starting mothod Piping mm Gas Connection method Suited area Controller type kg mm m2 AE142FCBKA 14000 16000 2 Power source Refrigerant Noise level(H/M/L) mm×mm×mm 674×225×450 18 6.35 9.52 flared 11~21 wired controller or remote controller 14000 10ϋ³×m³/h 1.8 Heat exchanger Refrigerant control method Dimension ˄L×W×H˅ External Weight Net Liquid AE092FCBKA 9000 11000 1.6 1PH 220V-230V 50HZ R407C R407C 36/32/29 36/32/29 centrifugal fan×2 centrifugal fan×2 520 / 420 / 300 520 / 420 / 300 Relay control Relay control Combination of wave cranny radiation fin and copper Capillary + EEV 674×225×450 18 6.35 9.52 mm×mm×mm Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 1PH 220V-230V 50HZ R407C 42/38/32 centrifugal fan×2 650 / 550 / 400 700/ 550 / 400 Relay control Relay control Combination of wave cranny radiation fin and copper Capillary + EEV 828×225×450 20 6.35 828×225×450 20 6.35 12.7 flared 12~23 12.7 flared 17~27 wired controller or remote controller -10- Commercial Air Conditioner Item model Cooling capacity Heating capacity Dehumidifying capacity Power source Refrigerant Noise level(H/M/L) 24000 28000 3 NˈVˈHz 1PH 220V-230V 50HZ 1PH 220V-230V 50HZ R407C 48 / 43 / 36 Controller type Piping Indoor unit Item Function Capacity Capacity Dehumidifying capacity Power cable Communication cable Power source Running current Unit model (color) Fan Type × Number Speed Motor output power Air-flows (H/M/L) Heat exchanger Type / Diameter Total area Temp. scope Dimension External (L×W×H) Package Drainage pipe material, diameter Controller type Refrigerant control Noise level H/M/L Weight Net / Shipping Refrigerant Type Pipe Liquid Gas Connecting method R407C 48 / 43 / 36 centrifugal fan×2 centrifugal fan×2 1000 /900/700 1000 /900/700 Relay control Relay control Combination of wave cranny radiation fin and Capillary + EEV Capillary + EEV mm×mm×mm kg mm mm 25 9.52 15.88 25 9.52 15.88 flared 23~36 wired controller or remote controller flared 32~49 wired controller or remote controller Connection method Suited area AE242FCBKA 18000 20000 10ϋ³×m³/h 2.4 dB(A) Heat exchanger Refrigerant control method Dimension ˄L×W×H˅ External Net Weight Liquid Piping Gas AE182FCBKA Btu/h Btu/h Type × Number Air-flow(H-M-L) m³/h starting mothod Fan Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA m 2 Model —— BTU/h W 10ϋ³×m³/h —— —— N, V, Hz A/A —— —— r/min W m³/h mm m² ć mm mm mm —— —— dB(A) kg / kg —— mm mm —— AS182FCBHA Cooling 18000 5200 Heating 20000 5800 2.0 3 × (1.0~1.5mm2 ) 2x(0.75~1.25mm2 ) 1, 220~230, 50 0.10 0.10 AS182FCBHA (white) CROSS×1 1350/1150/900 25 760/630/560 TP2M / 6.35×0.7 about 0.15 cooling: 6~7 / heating: 43~60 928×197×265 1025×309×330 PVC, 11.4/16.4 Phone type infrared EEV 44/41/38 11/14 R407C 6.35 12.7 Flared -11- Commercial Air Conditioner Piping Indoor unit Piping Indoor unit Item Model Function —— Capacity BTU/h Capacity W Dehumidifying capacity 10ϋ³×m³/h Power cable —— Communication cable —— Power source N, V, Hz Running current A/A Unit model (color) —— Fan Type × Number —— Speed r/min Motor output power W Air-flows (H/M/L) m³/h Heat exchanger Type / Diameter mm Total area m² Temp. scope ć Dimension External mm (L×W×H) Package mm Drainage pipe material, diameter mm Controller type —— Refrigerant control —— Noise level H/M/L dB(A) Weight Net / Shipping kg / kg Refrigerant Type —— Pipe Liquid mm Gas mm Connecting method —— Item Model Function —— Capacity BTU/h Capacity W Dehumidifying capacity 10ϋ³×m³/h Power cable —— Communication cable —— Power source N, V, Hz Running current A/A Unit model (color) —— Fan Type × Number —— Speed r/min Motor output power W Air-flows (H-M-L) m³/h Heat exchanger Type / Diameter mm Total area m² Temp. scope ć Dimension External mm (L×W×H) Package mm Drainage pipe material, diameter mm Controller type —— Refrigerant control —— Noise level H/M/L dB(A) Weight Net / Shipping kg / kg Refrigerant Type —— Pipe Liquid mm Gas mm Connecting method —— Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA AS072FCBHA AS092FCBHA Cooling Heating Cooling Heating 7000 9500 9000 10000 2000 2800 2600 3200 1.0 / 1.0 / 2 3 × (1.0~1.5mm ) 2 2x(0.75~1.25mm ) 1, 220~230, 50 0.10 0.10 0.10 0.10 AS072FCBHA (white) AS092FCBHA (white) CROSS×1 CROSS×1 1050/900/800 1250/1050/900 25 25 520/410/300 600/500/410 TP2M / 6.35×0.7 about 0.15 about 0.15 cooling: 6~7 / heating: 43~60 795×197×265 795×197×265 880×315×330 880×315×330 PVC, 11.4/16.4 Phone type infrared EEV 36/33/29 37/35/30 7.6/10.6 7.6/10.6 R407C 6.35 12.7 Flared AS122FCBHA AS142FCBHA Cooling Heating Cooling Heating 12000 15000 14000 17000 3500 4500 4000 5000 1.6 / 2.0 / 2 3 × 0.75mm 2x(0.75~1.25mm 2 ) 1, 220~230, 50 0.15 0.15 0.15 0.15 AS122FCBHA (white) AS142FCBHA (white) CROSS×1 CROSS×1 1250/1050/900 1250/1050/900 25 25 630/520/410 640/570/450 TP2M / 6.35×0.7 about 0.20 about 0.20 cooling: 6~7 / heating: 43~60 795×197×265 928×197×265 880×315×330 1025×309×330 PVC, 11.4/16.4 Phone type infrared EEV 39/37/30 44/41/38 7.6/10.6 11/14 R407C 6.35 12.7 Flared -12- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Norminal condition: indoor temperature (cooling): 27 ćDB/19ćWB, indoor temperature (heating): 20ćDB Outdoor temperature(cooling): 35ćDB/24ćWB, outdoor temperature(heating): 7ćDB/6ćWB The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level. The detailed method please refer to the following information: Installation state: the unit should be placed on the flat floor or be mounted in horizontal direction. Testing method: mounting-on-wall unit: built-in-ceiling unit: duct unit without auxiliary duct: 2m duct 1.4m 1.4m 0.8m 1m 1m outdoor unit: 1.air outlet from side: the noise level is the average sound pressure level measured from front, left, right directions. 2.air outlet from top: the noise level is the average sound pressure level measured from front, back, left, right directions. measured point: H ( height to the ground) = (h (unit height) + 1m) /2 and, it is 1m to each side. 1m 1m 1m h Note: Ĵ is the real time analyser position -13- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 3. Safety precaution Carefully read the following information in order to operate the airconditioner correctly. Below are listed three kinds of Safety Cautions and Suggestions. WARNING! Incorrect operations may result in severe consequences of death or serious injuries. CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences. INSTRUCTIONS: These information can ensure the correct operation of the machine. Be sure to conform with the following important Safety Cautions. The Safety Cautions should be at hand so that they can be checked at any time when needed. If the conditioner is transferred to the new user, this manual should be as well transferred to the new user. WARNING! If any abnormal phenomena is found (e. g.smell of firing), please cut off the power supply immediately, and contact the dealer to find out the handling method. Don't dismantle the outlet of the outdoor unit. The exposed fan is very dangerous which may harm human beings. In such case, to continue using the conditioner will damage the conditioner, and may cause electrical shock or fire hazard. switch off After the unit being used for a long time, the base should be checked for any damages. When the unit needs maintenance and repairment, please call dealer to handle it. Incorrect maintenance and repairment may cause water leak, electrical shock and fire hazard. If the damaged base is not repaired, the unit may fall down and cause accidents. -14- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA WARNING! Installed electrical-leaking circuit breaker. Nothing or nobody is permitted to placed on or stand on outdoor unit. It easily cause electrical shock without circuit breaker. The falling of goods and people may cause accidents. Air-conditioner can't be installed in the environment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard. Please let the dealer be responsible for installing the conditioner. Don't operate the air-conditioner with damp hands. Incorrect installation may cause water leak, electrical shock and fire hazard. Otherwise will be shocked. Call the dealer to take measures to prevent the refrigerant from leaking. If conditioner is installed in a small room be sure to take every measure in order to prevent suffocation accident Only use correctly-typed fuse. even in case of refrigerant leakage. May not use wire or any other materials replacing fuse, other-wise may cause faults or fire accidents. When conditioner is removed or reinstalled, dealer should be responsible for them. Incorrect installation may cause water leaking, electrical shock and fire hazard. Connect earthing wire. Earthing wire should not be connected to the gas pipe, water pipe, lightning rod or phone line, in-correct earthing may cause shock. Use discharge pipe correctly to ensure efficient discharge. Incorrect pipe use may cause water leaking. Earthing -15- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 4. Net dimension AU242FHBHA 948 Power wiring terminal 840 25 70 55 18 70 340 380 184 580 184 AU48* 948 Power wiring Terminal 580 184 70 55 25 18 380 340 1250 18 184 -16- Screw Hole (4xM10) Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA AB** Cassette unit: :;9 A9 ITL ZPM VITMRC ;>SS VITMR KMQRQTO B> :A9 ><>SS 7JMZ]MMT Y[YVMTYQUT VURMY8 NXMYP IQX PURM >@9SS 7QTLUUX [TQZ LQSMTYQUT8 ?>9SS 7KMQRQTO UVMTQTO LQSMTYQUT8 @99SS 7VITMR LQSMTYQUT8 :=9 GFEH D GFEH D AE** Ceiling concealed unit 54 25 100 25 225 b a 0 R1 55 C 30 240 R5 29(5 93 unit model a b c AE072FCBKA AE092FCBKA 615 650 452 AE122FCBKA AE142FCBKA 704 800 452 AE182FCBKA 858 1020 452 AE242FCBKA 990 1350 452 -17- <;9SS Y[YVMTYQUT PURLMX :>9SS @99SS 7VITMR LQSMTYQUT8 OIY VQVM ?>9SS 7KMQRQTO UVMTQTO LQSMTYQUT8 RQW[QL VQVM >@9SS 7QTLUUX [TQZ LQSMTYQUT8 LXIQTIOM VQVM U\MXRIVML LQYZITKM JMZ]MMT ZPM KMQRQTO ?9SS B9 Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA AS** series O :=DA I P Q FH@AE AS072FCBHA AS092FCBHA AS122FCBHA 462 AS142FCBHA AS182FCBHA 6/5 = > ? /32 .64 -18- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Dimensions for MP2A, MP3A: Installation on the horizontal ceiling: horizontal ceiling -19- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA vertical wall Installation on the vertical wall (adjust the installation position by fixing holder): -20- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 5. Installation Instructions 5.1 Piping dimension chart liquid pipe model mm inch AU24 9.52 3/8" AU48 9.52 3/8" AB09 6.35 1/4" AB14 6.35 1/4" AB18 6.35 1/4" AE07 6.35 1/4" AE09 6.35 1/4" AE12 6.35 1/4" AE14 6.35 1/4" AE18 9.52 3/8" AE24 9.52 3/8" AS07 6.35 1/4" AS09 6.35 1/4" AS12 6.35 1/4" AS14 6.35 1/4" AS18 6.35 1/4" gas pipe mm inch 15.88 5/8" 19.05 3/4" 12.7 1/2" 12.7 1/2" 12.7 1/2" 9.52 3/8" 9.52 3/8" 12.7 1/2" 12.7 1/2" 15.88 5/8" 15.88 5/8" 12.7 1/2" 12.7 1/2" 12.7 1/2" 12.7 1/2" 12.7 1/2" 5.2 Y-shape manifold pipe 12.7 15.9 9.52 12.7 15.88 9.52 75 model: FQG-B120 <gas side> 15.88 heat preservation material 9.52 12.7 <liquid side> 9.52 6.35 75 12.7 9.52 heat preservation material 12.7 9.52 Dimension is the out diameter connecting to the tubing. -21- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA FQG-B180 Refrigerant pipes between manifold pipes Total refrigerating amount of indoor unit Gas side Liquid side group after the manifold pipe Less than 38220Btu/h 15.9 9.52 38220~61157Btu/h 19.05 9.52 61157~126137Btu/h 25.4 12.7 Note: 1. Y-shape manifold pipe can be placed in horizontal or vertical direction 2. The manifold pipes must be welded with hard-solder 3. Pay attention to cut off the unnecessary part from its middle parts of each joint, and to remove burr. -22- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA In the file, the figure marked with "Ĝ" is permitted, and the figure marked with "h" is prohibited. You can confirm the position according to the actual condition. The refrigerant flow direction is always from the collective side to the divided side. horizontal horizontal floor surface floor surface floor surface floor surface vertical floor surface floor surface vertical floor surface floor surface floor surface -23- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 5.3 Instructions for the Electrical Expansion Valve Boxes The E.E.V.B. general information for the C-MRV and H-MRV indoor units. 1. Installation position 0° wiring connector 360° liquid pipe in/out 180° 0° Z: vertical direction X, Y: horizontal direction 2. Installation place The box should be installed where the place: a. do not have vibrations; b. easy to piping with the indoor and the outdoor unit, and the distance from the box to the indoor unit should not exceed a certain value; c. do not have a heat or steam source nearby; d. should be sunless and be dry; e. should be well ventilated and rainproof; f. do not have a strict noise restriction, because when working the box may make some noise; -24- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 5.4 MP2A, MP3A Installation Requirement vertical wall 1. Cautions 1.1 The place should be strong enough to support this equipment, no vibrantion; 1.2 The place where is convenient to install the indoor unit, outdoor unit and the refrigerant pipe, and the length of the pipe is in the permitted range; 1.3 No heat source and gas source nearby; 1.4 The place has enough space for installation and maintenance; 1.5 Donpt installation in the place in the state of high temperature and high humidity for a long time; 1.6 The place with good ventilation, no direct sunshine and rain; 1.7 Donpt install the unit near the bedroom because of the refrigerant flow noise; Please refer to the cautions and warnings in the operation manual about the other safety cautions. 2. Installation Method 2.1 MP2A, MP3A can be installed on the horizontal ceiling or the vertical wall by adjusting the fixing holder. The maintenance plate should be installed on the place easy to maintain and near the place, there should be checking hole with 600mm*600mm (adjust the fixing holder as below figure). 2.2 The equipment has been dealt with the EPS heat insulation material, so the drainage pipe needs not any other treatments. 2.3 The pipe connected to indoor is led from the branch pipe of the equipment. The gas pipe diameter can realize to match with different diameters by the changing pipe according to the indoor pipe diameter request. 2.4 In installation, the equipment gradient should be in the range of 5¤, or it may cause electronic expansion valve body in the equipment leakage or the other bad control failure. 2.5 Bolt, screw cap and gasket to fix the equipment will not be supplied by factory. 3. Wiring Connection 3.1 The wire and refrigerant pipe must be connected to the corresponding place (refer to marks on the equipment and the terminal block as 1,2,3). 3.2 Wiring diagram is sticked on the back of cover plate, and the wiring must be performed according to the wiring diagram, or the control will be bad or indoor and the equipment will be damaged. 3.3 After wiring, the wires must be fixed with the wire clip firmly, in case that the electric control parts are damaged or occurs person injury. -25- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 5.5 Connecting figure: 670 ;9E := LJ=< >FI KMF AE<FFI LEAKJ- GC=9J= ;FE>AID K@= 670 HL9EKAKO 9;;FI<AE? KF K@= 9;KL9C AE<FFI LEAKJ/ 671 ;9E := LJ=< >FI K@I== AE<FFI LEAKJ- GC=9J= ;FE>AID K@= 671 HL9EKAKO 9;;FI<AE? KF K@= 9;KL9C AE<FFI LEAKJ/ 5EJK9CC9KAFE D=K@F< AJ :=CFM- M@A;@ FECO K9B=J 671 9J 9E =N9DGC=/ 7C=9J= G9O 9KK=EKAFE K@9K K@= ?9J GAG=J AEJK9CC9KAFE AJ 9J K@= J9D= 9J K@= ;FE<AKAFE MAK@FLK 670+671,/ AE<FFI CAHLA< GAG= AE<FFI 2 QRP FLK<FFI CAHLA< GAG= AE<FFI 3 AE<FFI 4 AE<FFI 20 QRP 8.J@9G= D9EA>FC< GAG= Piping length and drop between units Haier + -26- AE<FFI 30 AE<FFI 40 Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 1) When connected with 8 units,indoor units refer to <admissible combination examples> 2) Total length=l1+l2*2+l3*4+l4*4+l5*4<=100m 3) Max. piping length =(l1+l2+l3+l5)<=70m 4) Max. piping length between the indoor unit and the first branch pipe<=30m 5) Max. drop between outdoor unit and indoor unit: H<=30m(indoor above outdoor);H<=20m(indoor below outdoor) 6) Max. drop between the two indoor units : h<=10m 7) Expansion valve is less than 15m to its corresponding indoor unit 8) Only wall mounted types are connected with expansion valves. 9) The expansion valves of different indoor models are different. 10)The first branch pipe must use FQG-180,the others use less than it. Combination example: 8 by 1: Haier AE07 AE07 MP3A AE07 AE07 AE07 MP3A AE07 AB09 AS07 EEV Note: 1.AU24 can connect with max. 5 indoor units, and AU48 can connect with max. 8 indoor units, but pay attention that the total indoor capacity can not exceed 130% of outdoor cooling capacity. 2. The ceiling concealed unit must connect with the outdoor unit through the MP2A or MP3A; the wall mounted unit must connect with the outdoor unit through the exterior EEV box; while for the cassette unit, because it has the built-in EEV, so it need not anything and it can connect to outdoor directly. -27- Commercial Air Conditioner 6 by one Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA AS09 (or other 9000BTU units) AS09 (or other 9000BTU units) Haier AS09 (or other 9000BTU units) AU48- AS09 (or other 9000BTU units) AS09 (or other 9000BTU units) EEV AS09 (or other 9000BTU units) -28- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 5.6 The Order of Installation Work Item Work Before installation Work division Make installation diagram Installation of indoor and outdoor unit Refrigerant pipe work Work Main points -to ascertain the person responsible for installation of pipes and wiring -to ascertain the pipe installation dimension and position of electronic expansion valve, to make control wiring system diagram -to prevent the ventilation from short circuit and guarantee repair space Drain pipe work -Pay attention to dry, clean and seal -Slant downward Heat insulation work -No gaps in the joint of heat insulation material Wiring work (control wire, power cord) Set every set switch -Choose the proper wire and cord Airtight test Vacuum drying Additional refrigerant Test run adjustment Training of use and maintenance -Should be complied with control wiring system diagram -Close all the gas, liquid valves -Should the vacuum pump that can reach 200Pa vacuity -Write down the additional refrigerant amount on the outdoor unit body and record table -Do test run to indoor unit one by one to verify if there is wrong pipes -Explain to user, simultaneously provide all the documents The above work order is general knowledge, they may be changed to be complied with the specific work site. 5.7 Attentive matters of safety Before installing, do read this [Attentive matters of safety] carefully to guarantee the proper installation. The below attentive matters are divided into [warning] and [note] two parts. When the wrong installation occur, it is very possible death and severe injury and other serious accidents will happen. For those items are listed in [warning] part. But even the items listed in [note] part can also cause serious accidents. Above all, both the two parts are very important contents related to safety, so they must be obeyed. After installation, do test run to verify everything is normal, after that please explains the use method and maintenance method to the user according to the operation manual. Additionally, give the installation manual together with operation manual to the user and ask them to keep them properly. Warning The distributing shop, where you bought the air conditioner, or the specified shops shall do the installation work. If you do the installation work by yourself, the improper installation will cause water leakage, electric shock fire and other accidents. The installation work shall be in line with what the installation manual specified. If installation is not proper, water leakage, electric shock, fire and other accidents will occur. Install the air conditioner to a place where can definitely stand its weight. Places not firm enough will cause drop down of unit resulting in body hurt. The installation work shall be preventive to typhoon and earthquake. If the installation -29- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA work is not met with the requirements, overturn of the unit will occur resulting in accidents. The wiring work shall be done by a qualified person and referred to the “technical standard of electric equipment”, “indoor wiring regulation” and what the manual specified. Do use special circuit. If the capacity of the circuit is not enough or bad work, electric shock, fire and other accidents will happen. Using the specified cable to do wiring work and connecting firmly and properly. Fix the connecting part of the terminals to prevent it from the external force. Improper connection and fixing will cause heating and fire etc. accidents. Wiring shall be kept in correct shape avoiding extrusion. After installation, the electric box cover and the external panel shall not nip the wire. Improper installation will cause heating and fire etc. accidents. When setting or moving the air conditioner do not let the air and things alike get into the refrigeration system except the specified refrigerant. If air and other things enter,abnormal high pressure will occur, which easily cause break and body injuries etc. When installing, do use the accessories or specified parts. If not using the parts specified by our company, water leakage, electric shock, fire and refrigerant leakage will occur. Do not lead the drainpipe to drain where the sulfur gas may be involved. Otherwise, the poisonous gas will enter into the indoor. During installation, if refrigerant leakage occurs, do the ventilation work immediately. As soon as the refrigerant gas meets fire, poisonous gas will be produce. If the refrigerant gas enters into room and meet the air blowing heater, heater or stove etc. fire source, the poisonous gas may be produced. After installation, confirm there is no leakage of refrigerant. Do not install the unit in a place where the combustible gas may be leaked. In any case the combustible gas leaks and accumulated around the unit, fire accident will occur. Do heat insulation work to the refrigerant gas pipes and liquid pipes to reach the purpose of heat preservation. If the heat insulation measure is not sufficient, water generated by condensing dew will drip leading to wet the floor and indoor articles. Do not damage the power line or change it arbitrarily to avoid occurrence of fire or electric shock. Do not extend the power line or using other electric appliance in the same power receptacle to avoid fire or electric shock. Note Do grounding work. Do not connect the grounding wire to gas pipe, tap, lighting rod or telephone line. Improper grounding will cause electric shock. In some places the electric leakage breaker shall be installed. If do not install the breaker, electric shock may occur. After installation, power on to do electric leakage detecting test. -30- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 5.8 Special Work and Main Points in Installation Warning During installation, if refrigerant leakage occurs, take ventilation measurement immediately. As soon as the leaked refrigerant gas meets fire, poisonous gas will generate. After finishing installation, confirm the refrigerant gas does not leak. If the refrigerant gas leaks in the room, once it meets heater, burner and gas stove etc. fire source, the poisonous gas will generate. A. Choosing of pipes According to the following indoor unit and outdoor unit installation diagram to choose the material and size of pipes and branch pipes. B. Connection of pipes 1 Method of pipe connection a. T he pipe shall be as short as possible to guarantee efficiency. b. Daub the refrigerant oil on the connection and flare nut. c. When bending the pipes, give the roundness as large as possible, to avoid crashing the pipes. d. To connect the pipe, fit the center and screw the nut with hand, then use spanner or torque wrench to tighten it. The fastening torque as shown in below table. As shown in figure. e. Be careful alien matters, such as sands, water etc. shall not enter the pipes. Forced fastening without careful centering may damage the threads and cause gas 2. Welding of pipes a. In welding, the nitrogen shall be used to avoid oxidation of the pipe inner part. b. The refrigerating pipe shall use clean new pipes. When working, it shall take steps to prevent water and dust from entering. c. When loosening and tightening the nuts, two spanners shall be used. If using one spanner, it can not reach the desired degree of tightness. Using the specified fastening torque to fasten nuts. Pipe diameter (mm) 6.35 9.52 12.7 15.88 Installation torque (N.M.) 11.8 (1.2kgf.m) 24.5 (2.5kgf.m) 49.0 (5.0kgf.m) 78.4 (8.0kgf.m) -31- Fastening torque (N.M.) 13.7 (1.4kgf.m) 29.4 (3.0kgf.m) 53.9 (5.5kgf.m) 98.0 (10.0kgf.m) Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA (4) Pipe connection of the outdoor unit Referring to the installation diagram in page 4, connect the indoor unit, outdoor unit, branch pipe and electronic expansion valve together by using the pipe connection method and welding method. -32- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 5.9 Test of leakage after wiring work is finished After connection of the refrigerant pipes, carry out leakage test. In this test, pressurize to the pipes as shown in the below figure by using nitrogen tank. Close the valves of the gas side and liquid side totally. The nitrogen may enter the cycle system of the outdoor unit, so that, before pressurizing, the valve rods must be fastened. (Both the gas side and liquid side). For each of the refrigerant system, pressurize from the discharge valve of gas side in procedure. When doing leakage test, it is absolutely forbidden to use oxygen, flammable gas and poisonous gas. The indoor unit expansion valve must be open. 5 vacuuming of the pipes and indoor unit (using vacuum pump to vacuums, it is strictly forbidden to use refrigerant purging) a. Choose of vacuum pump: it shall choose those that can reach a good vacuity (over 200Pa)and have a large air discharge amount (over 40L/min). b. After finishing the airtight quality test and the nitrogen discharging , connect the instrumental diverter to the 3-way discharge valve, then connect the vacuum pump according to the below figure. -33- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA c. Vacuumize 2~3 hours according to the length of the pipe. When vacuuming, confirm the gas side and liquid side of the 2-way valve and 3-way valve shall be in full close state. d. When it is not lower than 200Pa after 2 hours or more vacuuming, vacuums for another 1 hour. If after more than 3 hours vacuuming it is still not lower than 200Pa, the leak part shall be found. e. When it is lower than 200Pa after more than 2 hours vacuuming, close both the valve VL and VH of the diverter, then close the vacuum pump. Place it there to observe if the vacuity changes. If it changes, it indicates leakage exists, so the leak part shall be found. f. After finishing the above vacuuming work, replace the vacuum pump with refrigerant tank and turn to the refrigerant charging procedure. 5.10 Charging of refrigerant 1. Calculation of additional charging amount of refrigerant After finishing vacuuming work, replace the vacuum pump with refrigerant tank and turn to the refrigerant additional charging procedure. Calculation of additional charging amount of refrigerant Before the air conditioner leaving factory, the refrigerant-charging amount does not include the refrigerant in the site pipe part. Calculate the refrigerant amount for the site pipe first, then do the additional refrigerant charging work. Refrigerant charging amount when air conditioner leaves factoryR407C:4200g. Calculation method: According to the liquid pipe dimension of site pipe and actual length to calculate the additional refrigerant-charging amount. Calculation formula: Site refrigerant charging amount=Length of liquid pipe x additional refrigerant charging amount/m For example: additional charging amount R (kg) = (L1x0.030kg/m)+(L2x0.065kg/m) L1: Total length of liquid pipe diameter 6.35mm; L2: Total length of liquid pipe diameter 9.52mm. 2. Charging of refrigerant Close all valves of outdoor unit, and charge refrigerant from air discharge valve of gas side. When can not charge the specified amount, firstly, open all the valves, both liquid side and gas side, of outdoor unit, then switch the valve of gas side to close state a little. Under this condition, do cooling operation and charge refrigerant from the discharge valve of gas side. At this time, adjust the valve of the refrigerant tank to make the refrigerant in Gas State when it is absorbed by system. When refrigerant leakage making refrigerant lack in system occurs, the intrinsic refrigerant of the system shall be recovered and recharge it according to specified amount. 3. Opening of the refrigerant pipe Open all the valves of outdoor unit -34- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 5.11 Refrigerant QRU Y[cigWa W_g YdcZ_i_dc[g jh[h g[\g_][gWci :RGCIN:A T^_h g[\g_][gWci _ih[a\ _h _ccdYjdjh?cdc@YdbXjhi_Xa[ hW\[in g[\g_][gWciA Mji i^[c? l^[c WggWc]_c] i^[ W_g YdcZ_i_dc[g [fj_eb[ci? _i _h c[Y[hhWgn id iW`[ hdb[ hi[eh id iW`[ g[YWji_dch W]W_chi _c YWh[ d\ i^[ _cZddgh g[\g_][gWci a[W`W][A SjY^ Wh?i^[ gddb h_o[ h^Waa X[ iW`[c _cid WYYdjci id Wkd_Z bW`_c] i^[ YdcY[cigWi_dc d\ i^[ g[\g_][gWci cdi [mY[[Z i^[ YdcY[cigWi_dc a_b_i WcZ di^[g g[a[kWci hi[ehA T^[ YdcY[cigWi_dc a_b_i _h i^[ YdcY[cigWi_dc i^Wi _h cdi ^Wgb\ja id ^jbWc XdZn WcZ YWc iW`[ [b[g][cYn hi[eh id ig[Wi i^[ YdcY[cigWi_dc d\ Pg[dcA NdcY[cigWi_dc a_b_i d\ RGCINJ CAF`]BbF hW\[in g[\g_][gWciA DAS[fj[cY[ d\ g[\g_][gWci YdcY[cigWi_dc W\\_gbWcY[ NWaYjaWi[ i^[ g[\g_][gWci YdcY[cigWi_dc WYYdgZ_c] id i^[ \daadl_c] h[fj[cY[A D=NWaYjaWi[ i^[ idiWa g[\g_][gWci@Y^Wg]_c] Wbdjci d\ [WY^ d\ i^[ g[\g_][gWi_c] hnhi[b <`]=A p R[\g_][gWci Y^Wg]_c] Wbdjci d\ djiZddg hnhi[b > LZZ_i_dcWa g[\g_][gWci Y^Wg]_c] Wbdjci K TdiWa g[\g_][gWci Y^Wg]_c] Wbdjci d\ i^[ g[\g_][gWi_c] [fj_eb[ci <`]= p R[\g_][gWci Y^Wg]_c] Wbdjci d\ djiZddg hnhi[bJ R[\g_][gWci Y^Wg]_c] Wbdjci l^[c W_g YdcZ_i_dc[g a[Wk[h \WYidgnA p LZZ_i_dcWa g[\g_][gWci Y^Wg]_c] WbdjciJ LZZ_i_dcWa g[\g_][gWci Y^Wg]_c] Wbdjci WYYdgZ_c] id i^[ h_i[ e_e[ a[c]i^ WcZ e_e[ Z_Wb[i[gA E= NWaYjaWi[ i^[ b_c_bjb h_o[ d\ i^[ gddb hj_iWXa[ \dg i^[ _cZddg jc_i Whh[bXan <bF=A NWaYjaWi[ i^[ YdcY[cigWi_dc d\ g[\g_][gWciJ TdiWa g[\g_][gWci Y^Wg]_c] Wbdjci d\ g[\g_][gWi_c] [fj_eb[ciBi^[ b_c_bjb gddb h_o[ hj_iWXa[ \dg _cZddg jc_i Whh[bXan <bF=AR[\g_][gWci YdcY[cigWi_dc a_b_iJ CAF`]B bF EA Ndjci[gb[Whjg[ l^[c [mY[[Z_c] i^[ YdcY[cigWi_dc a_b_i 8 D= S[i Wc [\\[Yi_k[ de[c_c] \dg k[ci_aWi_dc WcZ \g[h^ W_gA p Nji Wc _ciW`[ g[he[Yi_k[an dc i^[ jee[g WcZ adl[g eWgi d\ i^[ Zddg l^_Y^ Wg[Wh Wg[ [fj_kWa[ci id CADH; ]gdjcZ_c] Wg[W? dg Yji Wc _ciW`[ _c di^[g eWgi d\ i^[ gddbA E= R[ZjY[ i^[ idiWa g[\g_][gWci Y^Wg]_c] Wbdjci d\ i^[ g[\g_][gWi_c] [fj_eb[ci p S^dgi[c i^[ g[\g_][gWci e_e[ a[c]i^A R[ZjY[ i^[ _chiWaaWi_dc eaWY[ Z_hiWcY[ X[il[[c i^[ djiZddg jc_i WcZ i^[ _cZddg jc_i id h^dgi[c i^[ g[\g_][gWci e_e[ a[c]i^? hd i^Wi g[ZjY[ i^[ idiWa g[\g_][gWci Y^Wg]_c] Wbdjci d\ i^[ g[\g_][gWi_c] [fj_eb[ciA F=OhiWXa_h^ k[ci_aWi_dc WcZ \g[h^ W_g hnhi[b p OhiWXa_h^ W b[Y^Wc_YWa [fj_eb[ci \dg \g[h^ W_g id `[[e i^[ g[\g_][gWci YdcY[cigWi_dc X[adl i^[ YdcY[cigWi_dc a_b_i <cdgbWa k[ci_aWi_dc= p V^[c YWc cdi k[ci_aWi[ i^[ cdgbWaan? ea[Wh[ h[i Wc WaWgb WeeWgWijh a_c`[Z l_i^ i^[ b[Y^Wc_YWa k[ci_aWi_dc [fj_eb[ciA -35- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 5.12 Electric cautions: Power supply specs model AU242FHBIA AU482FIBIA AU48NFIBJA AE*FCBKA AS*FCBHA Power source 1PH, 220-230V~, 50Hz 1PH, 220-230V~, 50Hz 3PH, 380-400V~, 50Hz 1PH, 220-230V~, 50Hz Connecting wire Circuit Power breaker cable 30A 5mm2 50A 10mm2 20A 4 mm2 Communication wire Wired controller wire core section area core section area 2 1.0-1.5mm2 3 15A 1.5mm AB*FCBIA 2 3 0.75mm2 3 Remark: 1. Must not connect the power cable and communication wire incorrectly. Forbidden to connect the power cable and communication wire with one muti-core cable, and they must be wired separately, keep proper distance between them to ensure the air conditioner run normally. 2. Communication wires among indoor units should be hand in hand type, and decrease the branch, also the shielded layer should be connected together and be earthed on one point. 3. All indoor communication wires will be connected to the communication bus wire (2-core), C1 and C2 are non-polar. 4. Because the indoor unit adopts EEV control method, when a sudden power off occurs, the EEV maybe keep some angle. If indoor unit and outdoor unit connect to power supply separately, when some indoor units running in cooling mode, when powered off, because the EEV does not reset, the indoor units maybe drop water, or ice up. We recommend that the indoor unit connect to power supply from the outdoor unit, or use one power supply with the outdoor unit. If the indoor unit need connect power supply individually, the personnel must explain to the customer that he (she) must switch off the unit with wired controller or remote controller, then he (she) can shut off the indoor unit. If there is accidental power failure, please firstly power on all the indoor units after power on, in order to reset the indoor EEV. 5. When wiring the MP2A or MP3A, please ensure that the power source and the communication wires of MP2A or MP3A must correspond with the relative indoor units. 6. AS*FCBHA and the cassette unit will not be connected with the MP2A or MP3A. 7. If the ceiling concealed indoor unit is with the electric heater, the circuit breaker will vary accordingly. -36- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 5.13 Indoor unit number setting: Indoor unit has two kinds of control type: infrared control and wired contrl, so the corresponding unit address setting will vary as the following: for the infrared control type unit, set with the address setting controller; for the wired control type unit, set with the dip switch, and the unit number is from 1 to 8. (1) Number setting for wired control type unit: 1 2 3 4 Indoor unit No. 0 0 0 0 1 1 0 0 0 2 0 1 0 0 3 1 1 0 0 4 0 0 1 0 5 1 0 1 0 6 0 1 1 0 7 1 1 1 0 8 Note: 1. Dip switch at ON position shows 0. 2. If there are not only the infrared control type unit also the wired control type unit in the whole system, please set the wired control type unit number firstly and then record the numbers, then set the infrared control type unit number, to avoid the repeated unit number. (2) Number setting for infrared control type unit: Please refer to the manual of address setting controller ASC-02. 5.14 The dip switch setting when out of factory: AE*FCBKA: Unit No.: 3; 3 fan speeds; wired control type; exterior EEV. That is: SW01-1 ON, SW01-2 OFF, SW01-3 ON, SW01-4 OFF; SW02-1 ON, SW02-2 OFF; SW03-1 ON, SW03-2 ON. AB*FCBIA: Unit No.: 3; 3 fan speeds; infrared control type; built-in EEV. That is: SW01-1 ON, SW01-2 OFF, SW01-3 ON, SW01-4 OFF; SW02-1 OFF, SW02-2 ON; SW03-1 OFF, SW03-2 ON. When installation, the installer should adjust the setting according to the actual condition. The ports functions for AB and AE unit (some are optional): port Corresponding parts port Corresponding parts CN4 Negative ion generator or high-voltage accumulator CN5 Gas/liquid pipe temp. sensor CN6 EEV CN7 Pump motor CN10 Indoor motor CN11 Float switch CN12 Swing motor CN13 Remote receiver CN14 Wired controller CN18 Neutral line of terminal block CN19 Auxiliary electric heating CN20 Live line of terminal block CN22 Auxiliary electric heating CN24 Room temp. sensor ˄ AE* unnecessary˅ CN25 Communication of EEV box CN9 Pre-set -37- Commercial Air Conditioner Cassette unit installation: t~,-w||w-{*~ v**|, Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Q^[ \ebbem_d] fWhji c[dj_ed[Z _d j^_i cWdkWb Wh[ j^[ _dijWbbWj_ed WYY[iieh_[i m[ fh[fWh[Z0 HdijWbbWj_ed jeebi Q^[ _dijWbbWj_ed jeebi b_ij[Z _d j^[ \ebbem_d] i^[[j YWd X[ ki[Z Wi h[gk_h[Z0 PocXeb NWhji LWc[ 30 PYh[m Zh_l[h 40 GWYaiWm 50 Ch_bb m_j^ W Z_Wc[j[h e\ 82cc 60 Hdd[h ^[nW]ed ifWdd[h.i^_\j_d] ifWdd[h 70 PfWdd[h ,36. 39. 3;.46.49cc80 N_f[ Ykjj[h 90 N_f[ [nfWdZ[h :0 Id_\[ ;0 N_dY[hi 320 J[WaW][ Z[j[Yjeh eh ieWfo mWj[h @ @Z^[i_l[ jWf[ A N_f[ YbWcf B Bedd[Yj_d] ^ei[ C ChW_dW][ ^ei[ D Led/^oZheiYef_Y ^[Wj _dikbWj_d] cWj[h_Wb E Fofikc femZ[h 330 AWdZ jWf[ 340 PYhWf[h 350 O[\h_][hWdj e_b t~,-w||w-{*~ u+*xzy.+z, 30P[b[Yj_ed e\ HdijWbbWj_ed NbWY[ ,3- NbWY[ WXel[ j^[ Y[_b_d] m^[h[ _j _i [dek]^ ifWY[ je WhhWd][ j^[ kd_j0 ,4- NbWY[ m^[h[ j^[ ZhW_dW][ f_f[ YWd X[ WhhWd][Z m[bb0 ,5- NbWY[ m^[h[ _db[j WdZ ekjb[j W_h e\ _dZeeh WdZ ekjZeeh kd_j m_bb dej X[ XbeYa[Z0 ,6- Ce dej [nfei[ j^[ kd_j je j^[ fbWY[ m_j^ ^[Wlo e_b eh ce_ijkh[ ,[0]0a_jY^[d WdZ mehai^ef-0 ,7- Ce dej i[j j^[ kd_j _d j^[ fbWY[ m^[h[ Z[ijhkYj_l[ ]Wi ,ikY^ Wi ikb\kh_Y WY_Z ]Wi- eh fkd][dj ]Wi ,j^_dd[h WdZ ]Wieb_d[- YedY[djhWj[i WdZ h[jW_di0 ,8- NbWY[ ijhed] [dek]^ je ikffehj j^[ kd_j 0 @_h ekjb[j 307c @_h _db[j 2053c G ,9- Le [nf[di_l[ Whj_Yb[i ikY^ Wi j[b[l_i_ed WdZ f_Wde X[bem _dZeeh kd_j0 ,:- Ddek]^ ifWY[ \eh cW_dj[dWdY[0 ,;- NbWY[ ceh[ j^Wd 3c WmWo \hec j[b[l_i_ed WdZ hWZ_e je Wle_Z Z_ijkhX_d] j[b[l_i_ed WdZ hWZ_e0 ,32- DWio \eh cW_dj[dWdY[0 @_h ekjb[j 307c 407c Ml[h -38- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 40HdijWbbWj_ed Nh[fWhWj_ed 372cc Pkif[dZ_d] Xebji B[_b_d] MhdWc[dj fWd[b C_ijWdY[ X[jm[[d ikif[dZ_d] Xebji 757cc 542cc Ml[hbWf X[jm[[d Y[_b_d] WdZ ehdWc[dj fWd[b i^Wbb X[ 47cc 82cc B[_b_d] ef[d_d] 872cc MhdWc[dj fWd[b 922cc HdZeeh kd_j 792cc ,3- Nei_j_ed e\ Y[_b_d] ef[d_d] X[jm[[d kd_j WdZ ikif[dZ_d] Xebj ,\hedj l_[m e\ kd_j-0 HdZeeh kd_j 792cc B[_b_d] ef[d_d] 872cc MhdWc[dj fWd[b 922cc ,4- Nh[fWh[ Wbb f_f_d] ,h[\h_][hWdj.mWj[h ZhW_dW][ -WdZ m_h[i ,Yedd[Yj_ed m_h[ e\ h[cej[ Yedjhebb[h. _dZeeh kd_j Yedd[Yj_ed m_h[i- je j^[ _dZeeh kd_j X[\eh[ _dijWbbWj_ed _d ehZ[h je Yedd[Yj _dZeeh kd_j _cc[Z_Wj[bo W\j[h _dijWbbWj_ed0 ,5- HdijWbb W ikif[dZ_d] Xebj Qe ikffehj j^[ kd_j m[_]^j .WdY^eh Xebj i^ekbZ X[ ki[Z _d j^[ YWi[ e\ j^[ [n_ij_d] Y[_b_d]0 Eeh d[m Y[_b_d]. ki[ \bki^/_d jof[ Xebj. Xk_bj/_d jof[ Xebj eh fWhji fh[jWh[Z _d j^[ \_[bZ0 A[\eh[ ]e_d] ed _dijWbb_d]. WZ`kij j^[ Z_ijWdY[ je Y[_b_d]0 72 q372cc Oee\ @dY^eh Xebj Jed] dkj eh j^h[WZ Pkif[dZ_d] X_bj K32 B[_b_d] >HdijWbbWj_ed DnWcfb[? Lej[< @bb j^[ WXel[ c[dj_ed[Z fWhji i^Wbb X[ fh[fWh[Z _d \[_bZ. j^[ Z_Wc[j[h e\ ikif[dZ_d] Xebj _i K32 50 HdijWbbWj_ed e\ _dZeeh kd_j Hd YWi[ e\ de Y[_b_d] HdijWbb kd_j j[cfehWh_bo Nkj ikif[dZ_d] XhWYa[j ed j^[ ikif[dZ_d] Xebj je ^Wd] j^[ kd_j kf0 A[ ikh[ je ki[ dkj WdZ mWi^[h Wj Xej^ [dZ e\ j^[ Xh[Wa[j je i[Ykh[ \_hcbo0 @\j[h _dijWbbWj_ed ed j^[ Y[_b_d] ,3- @Z`kij kd_j je _ji h_]^j fei_j_ed ,O[\[h je fh[fWhWj_ed \eh _dijWbbWj_ed/,3-,4-B^[Ya j^Wj kd_j _i ^eh_pedjWb0 TWj[h fkcf WdZ \beWj_d] im_jY^ _i _dijWbb[Z _di_Z[ _dZeeh kd_j.Y^[Ya \ekh Yehd[hi e\ j^[ kd_j \eh _ji b[l[h ki_d] ^eh_pedjWb YecfWhWjeh eh NSB jkX[ m_j^ mWj[h0,H\ kd_j _i j_bj_d] W]W_dij j^[ Z_h[Yj_ed e\ mWj[h ZhW_dW][.fheXb[c cWo eYYkh ed \beWj_d] mWj[h b[WaW][0- -39- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Hd j^[ YWi[ e\ [n_ij_d] Y[_b_d] Lkj ,Nh[fWh[ _d \[_bZ- ,3-HdijWbb kd_j j[cfehWh_bo TWi^[h ,Nh[fWh[Z _d \[_bZ- Nkj ikif[dZ_d] XhWYa[j ed j^[ ikif[dZ_d] Xebj je ^Wd] j^[ kd_j kf0A[ ikh[ je ki[ dkj WdZ mWi^[h Wj Xej^ [dZ e\ j^[ XhWYa[j je i[Ykh[ _j \_hcbo0 ,4-@Z`kij j^[ ^[_]^j WdZ fei_j_ed e\ j^[ kd_j0 ,5-NheY[[Z m_j^ fheY[Zkh[ ,6- e\ + Hd j^[ YWi[ e\ de Y[_b_d] + Pkif[dZ_d] Xebji EWij[d ,ZekXb[ dkji- Hdi[hj b[l[b[h TWi^[h \_n_d] fWZ ,fh[fWh[Z _d \[_bZU i[Ykh[ j^[ mWi^[h \_hcboV Neboj^[d[ f_f[ 60 HdijWbbWj_ed e\ mWj[h ZhW_dW][ f_f[ ,3- HdijWbb mWj[h ZhW_dW][ f_f[ N_f[ Z_Wc[j[h i^Wbb X[ [gkWb eh bWh][h j^Wd j^Wj e\ Yedd[Yj_d] f_f[ ,N_f[ e\ feboj^[d[= i_p[< 47cc= M0C0< 54cc ChW_df_f[ i^ekbZ X[ i^ehj. m_j^ W ZemdmWhZ ibef[ Wj b[Wij 31322 je fh[l[dj W_h XW] \hec \ehc_d]0 H\ ZemdmWhZ ibef[ e\ ZhW_df_f[ YWddej X[ cWZ[.b_\j_d] f_f[ i^Wbb X[ _dijWbb[Z0 I[[f W Z_ijWdY[ e\ 3/307c X[jm[[d ikif[dZ_d] Xebji. je cWa[ mWj[h ^ei[ ijhW_]^j0 3/307c ibef[ el[h 31322 Ri[ j^[ ZhW_dW][ ^ei[ WdZ Yb_f fhel_Z[Z m_j^ kd_j0 Hdi[hj mWj[h f_f[ _dje mWj[h fbk] kdj_b _j h[WY^[i j^[ m^_j[ jWf[0 Q_]^j[d j^[ Yb_f kdj_b ^[WZ e\ j^[ iYh[m _i b[ii j^Wd 6cc \hec ^ei[0 T_dZ j^[ ZhW_dW][ ^ei[ je j^[ Yb_f ki_d] i[Wb fWZ \eh ^[Wj _dikbWj_ed0 HdikbWj[ ZhW_dW][ ^ei[ _d j^[ heec0 Bb_f QWf[,m^_j[- Bb_f JWh][ i_p[ i[Wb fWZ ,WYY[iieho- ChW_d]W][ ^ei[ 6cc X[bem 70 BWkj_edi \eh j^[ mWj[h ZhW_dW][ b_\j_d] f_f[ HdijWbbWj_ed ^[_]^j e\ mWj[h ZhW_dW][ b_\j_d] f_f[ i^Wbb X[ b[ii j^Wd 4:2cc Bb_f 442cc -40- ChW_dW][ ^ei[ 722cc X[bem 11/ TWj[h ZhW_dW][ b_\j_d] f_f[ 722cc X[bem 522cc X[bem 3/307c Pkif[dZ_d] XhWYa[j 4:2cc kdj[h ChW_dW][ ^ei[ 97cc X[bem Q^[h[ i^ekbZ X[ W h_]^j Wd]b[ m_j^ kd_j .522cc \hec kd_j0 Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA > Lej[ ? Q^[ ibef[ e\ mWj[h ZhW_dW][ ^ei[ i^Wbb X[ m_j^_d 97cc . cWa[ j^[ ZhW_dW][ fbk] dej je X[Wh [nY[ii_l[ \ehY[0 H\ i[l[hWb mWj[h ^ei[i `e_d je][j^[h. e\ Wi f[h \ebbem_d] fheY[Zkh[i0 322cc rel[h Pbef[ X[bem 31322 Bedd[Yj_ed ZhW_dW][ ^ei[ m_j^ W Q/`e_dj Pf[Y_\_YWj_edi e\ j^[ i[b[Yj[Z ZhW_dW][ ^ei[i i^Wbb c[[j j^[ h[gk_h[c[dji \eh j^[ kd_j hkdd_d] 80 HdijWbbWj_ed e\ MhdWc[dj NWd[b HdijWbb ehdWc[dj fWd[b ed _dZeeh kd_j ,3- B^[Ya m^[j^[h _dZeeh kd_j _i ^eh_pedjWb m_j^ b[l[b[h eh feboj^[d[ f_f[ \_bb[Z m_j^ mWj[h . WdZ Y^[Ya j^Wj j^[ Z_c[di_ed e\ j^[ Y[_b_d] ef[d_d] _i Yehh[Yj0 QWa[ e\\ j^[ b[l[h ]Wk][ X[\eh[ _dijWbb_d] j^[ ehdWc[dj fWd[b0 ,4- EWij[d j^[ iYh[mi je cWa[ j^[ ^[_]^j Z_\\[h[dY[ X[jm[[d j^[ jme i_Z[i e\ _dZeeh kd_j b[ii j^Wd 7cc0 ,5- E_hijbo \_n _j m_j^ iYh[mi j[cfehWh_bo0 ,6- EWij[d j^[ jme j[cfehWh_bo \_n_d] iYh[mi WdZ ej^[h jme. WdZ j_]^j[d j^[ \ekh iYh[mi0 ,7- Bedd[Yj j^[ m_h[i e\ iodY^he/cejeh0 ,8- Bedd[Yj j^[ m_h[ e\ i_]dWb0 ,9- H\ de h[ifedi[ e\ h[cej[ Yedjhebb[h.Y^[Ya m^[j^[h j^[ m_h_d] _i Yehh[Yj.h[ijWhj h[cej[ Yedjhebb[h 32 i[YedZi W\j[h i^kj e\\ fem[h ikffbo0 Db[Yjh_Y Yedjheb Xen NWd[b b_c_jWj_ed XeWhZ _dijWbbWj_ed ,3-HdijWbb j^[ fWd[b XeWhZ _d j^[ Z_h[Yj_ed i^emd _d j^[ \_]kh[0 ,4-Q^[ _dYehh[Yj Z_h[Yj_ed m_bb h[ikbj _d mWj[h b[WaW][.c[Wdm^_b[ im_d] WdZ i_]dWb h[Y[_l_d] Wh[ Z_ifbWo[Z j^Wj YWddej X[ Yedd[Yj[Z0 N_f_d] Bedd[Yj_ed EbWh[ Yedd[Yj_ed 5/mWo lWbl[ FWi f_f[ HdZeeh Rd_j MkjZeeh kd_j J_gk_Z f_f[ EbWh[ Yedd[Yj_ed -41- 4/mWo lWbl[ Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Installation for wall mounted unit Please read these "Safety Precautions" first then accurately execute the installation work. The precautionary points indicated herein are divided under two headings: ! WARNING and ! CAUTION those points which are related to the strong possibility of an installation done in error resulting in death or serious injury are listed in the ! WARNING section. However, there is also a possibility of serious consequences in relationship to the points listed in the ! CAUTION section as well. In either case, important safety related information is indicated, so by all means, properly observe all that is mentioned. After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user of this equipment, based on the owner's manual. Moreover, ask the customer to keep this sheet together with the owner's manual. WARNING Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage electric shocks and fires. Execute the installation accurately, based on following the installation manual. Again improper installations can result in water leakage, electric shocks and fires. Please install your air conditioner on a wall or any place which can holder the weight of the air conditioner. And it cannot be installed on a non-professional metal structure (such as a burglary-resisting net). Otherwise injury would occur due to a falling of the unit. Execute the prescribed installation construction to prepare for earthquakes and the strong airs of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit. Wiring shall be done with the specified cable and the connection shall be firm and reliable. And the terminal connector shall be fixed firmly and reliably not to let external force exercise on the cables. Any improper connection or fixing would cause heat, fire, and other accidents. Wiring shall be done in a correct shape not to make any section rise upward, and accurately install the air conditioner. The cable shall not be clamped by the lid or outer plate. Any improper installation would lead to fire, heat, or other accidents. When setting up or moving the location of the air conditioner, do not mix air etc, or anything other than the designated refrigerant (R407C) within the refrigeration cycle, for such mixing would result in rupture and injury caused by abnormal high pressure. Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage. The drain pipe must not be placed or connected into the sewage tank where harmful gas such as sulphurous gas and etc would exist, otherwise the harmful gas would enter the room. During installation, if the refrigerant is leaked, please immediately take measures of ventilation, otherwise a harmful gas would be generated whenever the refrigerant meets fire. After installation, please ensure that the refrigerant is not leaked, because the leakage of refrigerant would produce a harmful gas if it meets fire or heating stoves. Don't install the air conditioner where a flammable gas would be probably produced, otherwise in case the flammable gas is leaked and exists around the unit, fire would be caused. For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items. The refrigerant gas pipe and liquid pipe shall all be thermally insulated to preserve the temperature. Any improper insulation would make the unit moist and the water would drop onto the floor or wet the indoor items. -42- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA PRECAUTION Execute proper grounding. Do not connect the earth wire to a gas pipe, water pipe, lightening rod, or a telephone ground wire. Improper placement of earth wires can result in electric shock. An electric leakage breaker must be installed, otherwise electric shock or other accidents would occur. After completion of the installation, the air conditioner shall be electrified to check for electric leakage. Preparation for installation Installation Tools 1. Screw Driver (flat head, wabbler, triangle) 2. Steel Saw 3. 60mm Drill 4. Inner Hexagon Spanner 5. Shifting Spanner 6. Spanner 7. Pipe Cutter 8. Pipe Expander 9. Knives 10. Clippers 11. Leakage Checker or Soap Liquid 12. Measuring Tape 13. Scraper or File 14. Refrigeration Oil Self-contained Accessories No. A B Name of Non-adhesive Adhesive Tape Parts tape C D Connecting Heat insulation Hose material E Gypsum powder F Drain hose Electrical Requirements Power supply voltage: Single Phase 1PH, 220-230V~, 50Hz. A specialized power supply wire, which shall be installed by a competent person as per the rules of the national standard. Power supply must be grounded effectively. An electric leakage breaker shall be installed. Layout of power supply wiring shall be Y connection. If the power supply wire is damaged, it must be replaced by the manufacturer or its service center or professional person (the power supply wire shall be self-contained). For connection of the power supply plug, L shall be connected with the live wire, N shall be connected with netural line, shall be connected with earth wire. 2 Power supply wire parameters:H05RN-F,3 G(1.0-1.5)mm ; 2 Signal wire parameters:H05RN-F,2 X (0.75-1.5)mm . (User shall self-provide signal wire ) Note:The singnal wire and connection wire should be provided for oneself. The singnal wire must be shielded wire ! WARNING BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION AND/OR PROPERTY DAMAGE. BE SURE TO READ INSTALLATION MANUAL FOR INDOOR UNIT WITH THIS MANUAL. -43- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 1.Accessories Confirm accessories shown below are attached in the bag with this Installation manual. Accessories Delivered with Your Air Conditioner Please check if your unit is delivered with the following accessories. No. Name 1 2 Remote controller Batteries 3 Mounting plate 4 6 5 Drain hose 4x25 screw Expansion bushing 7 8 9 Cement Piping hole Screw steel nail cover and 10 Plastic supporting plate shape Qty 1 2 1 1 6 6 8 1 2 1 Indoor Unit Install the indoor unit where the weight of the unit can be supported. Install the indoor unit where the heat source and steam source are not close and the Unit inlet and outlet are not blocked. Install the indoor unit where the drainage is easy and the outdoor unit can be Easily connected. Install the indoor unit where its cold air and hot air can be easily sent to all the comers of the room. Install the indoor unit where the power socket is near and there is sufficient space around the indoor unit. Install the indoor unit where there is no T.V set, radio set, and wireless appliance Underneath, and the sunlight lamp is over one meter away. If the remote controller is installed on the wall, the indoor unit shall be ensured to receive The signal while the sunlight lamp is on. Method for Cutting and Expanding Pipes. When the pipe is too long or the mouth is damaged, the pipe needs to cut or expanded. 3.Put on nut 4.Expand Hose 2.Removing burr 1.cutting hose Expansion Size A Hose dia. 6.35 mm(1/4) 12.7 mm(1/2) Size (mm)A 0.8-1.5 1.0-2.0 Hose Expander Not Correct Correct Tilting cracks on expanded mouth burr -44- incomplete too long Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA When the mounting plate is firstly fixed 1. Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. 2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail. 3. Making a Hole on the wall and Fitting the piping Hole cover Make a hole of 60mm in diameter, slightly descending to outside the wall. Indoor side Install piping hole cover and seal it off with putty after installation. Wall hole Outdoor side Thickness of wall 60mm 4. Drawing of pipe (Section of wall hole) Piping hole pipe Rear piping Draw pipes and the drain hose, then fasten them with the adhesive tape. Left Left-rear, piping In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials. a. Insert the drain hose into the dent of heat insulation materials of indoor unit. b. Insert the indoor/outdoor electric cord from backside of indoor unit, and pull it out on the front side, then connect them. c. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape. Heat insulation material Piping Pipe supporting plate Drain hose Lid for right piping Indoor/Outdoor Electric cable Lid for left piping Lid for under piping pipe Fix with adhesive tape Indoor/outdoor electric cord and drain hose must be bound with refrigerant piping by Protecting tape. -45- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Other direction piping Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole. When bending, be careful not to crash pipes. Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially. 5.Fixing the indoor unit body Hang surely the unit body onto the upper notches of the mounting plate. Move the body from side to verify its secure fixing. In order to fix the body onto the mounting plate, hold up the body aslant from the underside and then put it down perpendicularly. Putty Electric wiring When connecting the cord before installing the indoor unit Insert the cord from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cord ends fully into terminal block, then tighten the screws. Pull the cord slightly to make sure the cords have been properly inserted and tightened. After the cord connection, never fail to fasten the connected cord with the wiring cover. Note: when connecting the cord, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. ! CAUTION After connecting the piping, check the joints for gas leakage with gas leakage detector. HOW TO CONNECT WIRING TO THE TERMINALS A. For solid core wiring (or F-cable)(Fig.17A) (1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 25mm of the exposed solid wire. (2) Using a screwdriver, remove the terminal screw (s) on the terminal board. (3) Using pliers, bend the solid wire to form a loop suitable for the terminal screw. (4) Shape the loop wire properly, place it on the terminal board and tighten securely with the terminal screw using a screw driver. B. For strand wiring (Fig.17B) (1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 10mm of the exposed strand wiring. (2) Using a screwdriver, remove the terminal screw (s) on the terminal board. (3) Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end. (4) Position the round terminal wire, and replace and tighten the terminal screw using a screw driver. Fig. 17 B. Strand wire Loop Insulation Strip 10mm Strip 25mm A. Solid Round terminal After passing the connection cord and power cable through the insulation tube, fasten it with the cord clamp, as shown in Fig.18 -46- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Fig. 18 Screw with special washer Insulation tube Cord clamp Wire Round terminal Terminal board Screw with special washer Round terminal Wire Use VW-1, 0.5 to 1.0 mm thick, PVC tube as the insulation tube. Check the Layout of the Drain Pipe and Connection Wires The drain pipe should be placed underneath, and the connection wires should be placed upside; and the drain pipe especially the section inside the machine and indoors must be wound up with insulating material to preserve heat. The drain pipe shall be sloped and no concave and convex shall occur along the whole pipe. And the cases as the right figure indicates shall not occur. Installation check Is power supply voltage required? Is water completely drained to outdoors? Are power wire and connection wires between indoor and outdoor units correctly connected? Is any gas leaked from the pipe connectors? Are series numbers of the terminals on the indoor and outdoor units corresponding to each other? Is the connection section of the auxiliary pipe insulated? Is the indoor unit fixed firmly? Is noise big? Trial Operation The person who has completed this installation shall be requested to conduct a test operation for check: Is the temperature adjuster working normally? Does the location for installation conform to requirements? Winding up with Protective Plastic Tape The connection pipes, drain pipe, and the connection wires shall be wound up with PVC tape. Notes: The connection pipes shall also be wound up with insulating material to preserve the temperature. The airing direction shall be from bottom to top. -47- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Ceiling concealed OIEN 6IMN=GG=NEJI MK=?A S_\ `e[ffi le`k j_Xcc Y\ `ejkXcc\[ Xk cfZXk`fej n_\i\ Zfc[ Xe[ _fk X`i Zflc[ \m\ecp Z`iZlcXk\[4 S_\ ]fccfn`e^ cfZXk`fej j_flc[ Y\ Xmf`[\[@ OcXZ\j n`k_ i`Z_ jXck /j\Xj`[\ Xi\X04 OcXZ\j n`k_ gc\ekp f] ^Xj jlc]`[\j /dX`ecp `e nXid jgi`e^ Xi\Xj n_\i\ k_\ Zfgg\i klY\ Xe[ YiXq\ n\c[ `j \Xjp kf Zfiifj`fe04 KfZXk`fej n`k_ dlZ_ f`c /`eZcl[`e^ d\Z_Xe`ZXc f`c0 Xe[ jk\Xd4 KfZXk`fej lj`e^ fi^Xe`Z jfcm\ekj4 OcXZ\j n_\i\ k_\i\ Xi\ dXZ_`e\j ^\e\iXk`e^ HF \c\ZkifdX^e\k`Z nXm\j4 Ofj`k`fej X[aXZ\ek kf [ffi fi n`e[fn `e ZfekXZk n`k_ _`^_3_ld`[`kp \ok\ieXc X`i4 /EXjp kf ^\e\iXk\ [\n04 KfZXk`fej ]i\hl\ekcp lj`e^ jg\Z`Xc X\ifjfcj4 9DA BJGGJPEIC KJEINM MDJOG@ >A N=FAI ?=LA JB0 74 R\c\Zk jl`kXYc\ gcXZ\j k_\ flkc\k X`i ZXe Y\ j\ek kf k_\ \ek`i\ iffd2 Xe[ Zfem\e`\ek kf cXp flk k_\ Zfee\Zk`fe g`g\2 Zfee\Zk`fe n`i\ Xe[ k_\ [iX`eX^\ g`g\ kf flk[ffi4 84 S_\ Z\`c`e^ jkilZkli\ dljk Y\ jkife^ \efl^_ kf jlggfik k_\ le`k n\`^_k4 94 S_\ Zfee\Zk`e^ g`g\2 [iX`e g`g\ Xe[ Zfee\Zk`fe n`i\ F`^ 7 j_Xcc Y\ XYc\ kf ^f k_fl^_ k_\ Yl`c[`e^ nXcc kf Zfee\Zk Y\kn\\e k_\ `e[ffi Xe[ flk[ffi le`kj4 :4 S_\ Zfee\Zk`e^ g`g\ Y\kn\\e k_\ `e[ffi Xe[ flk[ffi le`kj Xj n\cc Xj k_\ [iX`e g`g\ j_Xcc Y\ Xj j_fik Xj gfjj`Yc\4 /R\\ F`^li\ 70 ;4 I] `kj e\Z\jjXip kf X[aljk k_\ ]`cc`e^ Xdflek f] k_\ i\]i`^\iXek2 gc\Xj\ i\]\i kf k_\ `ejkXccXk`fe dXelXc XkkXZ_\[ n`k_ k_\ flk[ffi le`k4 <4 S_\ Zfee\Zk`e^ ]cXe^\ j_flc[ Y\ gifm`[\[ Yp k_\ lj\i _`dj\c]4 =4 S_\ `e[ffi le`k _Xj knf nXk\i flkc\kj fe\ f] n_`Z_ `j fYjkilZk\[ Xk k_\ ]XZkfip /n`k_ X ilYY\i ZXg04 Necp k_\ flkc\k efk fYjkilZk\[ /c`hl`[ `ec\k Xe[ flkc\k j`[\0 n`cc Y\ ^\e\iXccp lj\[ [li`e^ `ejkXccXk`fe4 I] Xggc`ZXYc\2 Yfk_ k_\ flkc\kj j_flc[ Y\ lj\[ kf^\k_\i4 Mfk\@ S_\ XZZ\jj _fc\ dljk Y\ gifm`[\[ [li`e^ `ejkXccXk`fe f] `e[ffi le`k ]fi dX`ek\eXeZ\4 1BNAL MAGA?NEIC NDA EIMN=GG=NEJI MK=?A{ KLJ?AA@ NDA BJGGJPEIC MNAKM0 74 Di`cc X _fc\ `e k_\ nXcc Xe[ `ej\ik k_\ Zfee\Zk`e^ g`g\ Xe[ n`i\ k_ifl^_ X OUC nXcc3 k_ifl^_ klY\ gliZ_Xj\[ cfZXccp4 S_\ nXcc _fc\ j_Xcc Y\ n`k_ X flknXi[ [fne jcfg\ f] Xk c\Xjk 757664 /R\\ F`^li\ 80 84 B\]fi\ [i`cc`e^ Z_\Zb k_Xk k_\i\ `j ef g`g\ fi i\`e]fiZ`e^ YXi aljk Y\_`e[ k_\ [i`cc`e^ gfj`k`fe4 Di`cc`e^ j_Xcc Xmf`[ Xk gfj`k`fej n`k_ \c\Zki`Z n`i\ fi g`g\4 94 Lflek k_\ le`k fe X jkife^ Xe[ _fi`qfekXc Yl`c[`e^ iff]4 I] k_\ YXj\ `j efk ]`id2 `k n`cc ZXlj\ ef`j\2 m`YiXk`fe fi c\XbX^\4 :4 Rlggfik k_\ le`k ]`idcp4 F`^ 8 ;4 C_Xe^\ k_\ ]fid f] k_\ Zfee\Zk`fe g`g\2 Zfee\Zk`fe n`i\ Xe[ [iX`e g`g\ jf k_Xk k_\p ZXe ^f k_ifl^_ k_\ nXcc _fc\ \Xj`cp4 EXZ_ f] k_\ X`i j\e[`e^ [lZk Xe[ X`i i\klie [lZk j_Xcc Y\ ]`o\[ fe k_\ gi\]XYi`ZXk\[ gXe\c f] k_\ ]cffi Yp k_\ `ife YiXZb\k4 S_\ i\Zfdd\e[\[ [`jkXeZ\ Y\kn\\e k_\ \[^\ f] k_\ X`i i\klie [lZk Xe[ k_\ nXcc `j fm\i 7;6dd4 S_\ ^iX[`\ek f] k_\ Zfe[\ejXk\ nXk\i g`g\ j_Xcc b\\g fm\i 7.4 S_\ Zfe[\ejXk\ nXk\i g`g\ j_Xcc Y\ k_\idXc `ejlcXk\[4 V_\e `ejkXcc`e^ k_\ Z\`c`e^ CfeZ\Xc\[ kpg\ `e[ffi le`k2 k_\ X`i i\klie [lZk dljk Y\ [\j`^e\[ Xe[ `ejkXcc\[ /Xj ]`^li\ j_fne04 -48- Commercial Air Conditioner Bl`c[`e^ iff] f] `ejkXccXk`fe Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA X`i i\klie Yfo A`i flkc\k ^i`cc\ 746d /lj\ n_`k\ dfkfi gcl^0 ;46d/lj\ i\[ dfkfi gcl^0 A`i jlggcp + Z\`c`e^ le`k X`i i\klie Yfo X`i i\klie X`i jlggcp S_\i\ j_flc[ Y\ ef fYjkXZc\j n`k_`e 7d le`k X`i i\klie Mfk\@ V_\e Zfee\Zk`e^ k_\ j_fik [lZkj2 lj\ k_\ cfn jkXk`Z k\id`eXcj2 n_`Z_ Zfcfi `j n_`k\4 S_\ [`jkXeZ\ K ]ifd k_\ X`i flkc\k f] k_\ [lZk kf k_\ X`i flkc\k f] k_\ j`i Zfe[`k`fe\i j_Xcc Y\ ef dfi\ k_Xe 7 d4 Rljg\e[`e^ _ffb DiX`e g`g\ A`i flk [lZk A`i i\klie [lZk A`i i\klie Yc`e[ SiXej`k`fe [lZk A`i [`jki`YlkXip S`\3`e f] X`i [`jki`YlkXip S_\ jb\kZ_ dXg f] cfe^ [lZk Mfk\@ V_\e Zfee\Zk`e^ k_\ cfe^ [lZkj2 lj\ k_\ d`[[c\ jkXk`Z k\id`eXcj2 n_`Z_ Zfcfi `j i\[4 S_\ [`jkXeZ\ K ]ifd k_\ X`i flkc\k f] k_\ [lZk kf k_\ X`i flkc\k f] k_\ j`i Zfe[`k`fe\i j_Xc Y\ ef dfi\ k_Xe ; d4 L> n`[\ \ogXej`fe Yfck L> jljg\e[\i jZi\n A`i Zfe[`k`fe\i L> n`[\ cfZb nXj_\i L> jZi\n elk IejkXccXk`fe f] `e[ffi le`k [lZk 74 IejkXccXk`fe f] X`i j\e[`e^ [lZk S_`j le`k lj\j ifle[\[ [lZk2 k_\ [`Xd\k\i f] k_\ [lZk `j 7>6dd4 S_\ ifle[ [lZk e\\[j kf X[[ X kiXej`k`fe [lZk kf Zfee\Zk n`k_ k_\ X`i3j\e[`e^ [lZk f] `e[ffi le`k2k_\e Zfee\Zk n`k_ i\jg\Zk`m\ j\gXiXkfi4 Aj F`^4 7 j_fne2 Xcc k_\ ]Xe jg\\[ f] Xep f] k_\ j\gXiXkfiuj X`i flkc\k j_Xcc Y\ X[aljk\[ Xggifo`dXk\cp k_\ jXd\ kf d\\k k_\ i\hl`i\d\ek ]fi k_\ iffd X`i Zfe[`k`fe\i4 Ie[ffi le`k ]c\o`Yc\ af`ek SiXej`k`fe [lZk Qfle[\[ [lZk S`\3`e f] X`i [`jki`YlkXip A`i [`jki`YlkXip F`^4 7 Te`k@ dd 84 IejkXccXk`fe f] X`i i\klie [lZk Tj\ i`m\k kf Zfee\Zk k_\ X`i i\klie [lZk fe k_\ X`i i\klie `ec\k f] k_\ `e[ffi le`k2 k_\e Zfee\Zk k_\ fk_\i \e[ n`k_ k_\ X`i i\klie Yc`e[4 Aj F`^4 8 j_fne4 -49- Commercial Air Conditioner A`i i\klie Yc`e[ A`i i\klie [lZk Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Ie[ffi le`k i`m\k F`^4 8 9 S_\idXc `ejlcXk`fe f] [lZk A`i3j\e[`e^ [lZk Xe[ X`i i\klie [lZk j_Xcc Y\ k_\idXccp `ejlcXk\[4 F`ijk jk`Zb k_\ ^cl\p eX`c fe k_\ [lZk2 k_\e XkkXZ_ k_\ _\Xk gi\j\imXk`fe Zfkkfe n`k_ X cXp\i f] k`e]f`c gXg\i Xe[ lj\ k_\ ^cl\p eX`c ZXg kf ]`o4 F`eXccp lj\ k_\ k`e]f`c X[_\j`m\ kXg\ kf j\Xc k_\ Zfee\Zk\[ gXik4 Aj F`^4 9 j_fne4 ^cl\p ^cl\p _\Xk gi\j\imXk`fe k`e]f`c eX`c ZXg Zfkkfe eX`c X[_\j`m\ kXg\ F`^4 9 IejkXcc`e^ k_\ jljg\ej`fe jZi\n@ Tj\ L> fi L76 jljg\ej`fe jZi\nj /:2gi\gXi\[ `e k_\ ]`\c[0/n_\e k_\ jljg\ej`fe jZi\n_\`^_k \oZ\\[j 64?d2 L76 j`q\ `j k_\ fecp Z_f`Z\04S_\j\ jZi\nj j_Xcc Y\ `ejkXcc\[ Xj ]fccfnj n`k_ jgXZ\ X[Xgk`e^ kf X`i Zfe[`k`fe\i fm\iXcc [`d\ej`fej XZZfi[`e^ kf k_\ fi`^`eXc Yl`c[`e^ jkilZkli\j4 Vff[\e jkilZkli\ A jhlXi\ nff[ j_Xcc Y\ jlggfik\[ Yp k_\ Y\Xdj Xe[ k_\e j\k k_\ jljg\ej`fe jZi\nj4 B\Xd RhlXi\ nff[ M\n ZfeZi\k\ jcXY Sf j\k n`k_ \dY\[[\[ gXikj2]fle[Xk`fe Yfckj \kZ4 Rljg\ej`fe jZi\n Iife i\`e]fiZ\d\ek Ffle[Xk`fe Yfck Je`]\ \dY\[[\[ gXik Gl`[\ gcXk\ \dY\[[\[ gXik O`g\ jljg\ej`fe ]fle[Xk`fe Yfck Ni`^`eXc ZfeZi\k\ jcX[ HXe^`e^ Yfck Tj\ _fc\ _`e^\2_fc\ gcle^\i fi _fc\ Yfck4 Rk\\c i\`e]fiZ\d\ek jkilZkli\ Tj\ jk\\c Xe^c\ fi e\n jlggfik jk\\c Xe^c\ [`i\Zkcp4 Rljg\ej`fe jZi\n HXe^`e^ f] k_\ `e[ffi le`k Rlggfik jk\\c Xe^c\ FXjk\e k_\ elk fe k_\ jljg\ej`fe jZi\n Xe[ k_\e _Xe^ k_\ jljg\ej`fe jZi\n `e k_\ S jcfk f] k_\ jljg\ej`fe gXik f] k_\ le`k4 A`[\[ n`k_ X c\m\c d\k\i2X[aljk c\m\c f] k_\ le`k n`k_`e ;dd4 w 3=ONEJI Ie fi[\i kf [iX`e nXk\i efidXccp2 k_\ [iX`e g`g\ j_Xcc Y\ gifZ\jj\[ Xj jg\Z`]`\[ `e k_\ `ejkXccXk`fe dXelXc Xe[ j_Xcc Y\ _\Xk `ejlcXk\[ kf Xmf`[ [\n ^\e\iXk`fe4 Idgifg\i _fj\ Zfee\Zk`fe dXp ZXlj\ `e[ffi nXk\i c\XbX^\4 -50- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Q\hl`i\d\ekj S_\ `e[ffi [iX`e g`g\ j_Xcc Y\ k_\idXc `ejlcXk\[4 S_\ Zfee\Zk`fe gXik Y\kn\\e k_\ [iX`e g`g\ Xe[ k_\ `e[ffi le`k j_Xcc Y\ `ejlcXk\[ jf Xj kf gi\m\ek [\n ^\e\iXk`fe4 S_\ [iX`e g`g\ j_Xcc Y\ jcXek [fnenXi[j /^i\Xk\i k_Xe 7576604 S_\ d`[[c\ gXik j_Xcc efk Y\ f] R kpg\ \cYfn2 fk_\in`j\ XYefidXc jfle[ n`cc Y\ gif[lZ\[4 S_\ _fi`qfekXc c\e^k_ f] k_\ [iX`e g`g\ j_Xcc Y\ c\jj k_Xe 86 d4 Ie ZXj\ f] cfe^ g`g\2 jlggfikj j_Xcc Y\ gifm`[\[ \m\ip 74; t 8d kf gi\m\ek nXmp ]fid4 C\ekiXc g`g`e^ j_Xcc Y\ cX`[ flk XZZfi[`e^ kf k_\ ]fccfn`e^ ]`^li\4 SXb\ ZXi\ efk kf Xggcp \ok\ieXc ]fiZ\ fekf k_\ [iX`e g`g\ Zfee\Zk`fe gXik4 74;dr8d Rlggfik IejlcXk`fe Dfne jcfg\ /jlggc`\[ Yp k_\ lj\i0 XYfm\ 75766 R kpg\ \cYfn VXcc Sf k_\ cXi^\jk /Xgg4 76Zd0 Nlkj`[\ UO96 Dfne jcfg\ XYfm\ 75766 RcXek O`g\ Xe[ `ejlcXk`fe dXk\i`Xc O`g\ DiX`e g`g\ /jlggc`\[ Yp k_\ lj\i0 Q`^`[ OUC g`g\ UO974;dd /`ek\ieXc [`Xd\k\i0 IejlcXk`fe FfXd\[ OE n`k_ k_`Zbe\jj XYfm\ = dd Hfj\ DiX`e g`g\ j`q\@ /95:-0 OUC g`g\ S_\ _fj\ `j lj\[ ]fi X[aljk`e^ k_\ f]]3Z\ek\i Xe[ Xe^c\ f] k_\ i`^`[ OUC g`g\4 D`i\Zkcp jki\kZ_ k_\ _fj\ kf `ejkXcc n`k_flk dXb`e^ Xep [\]fidXk`fe4 S_\ jf]k \e[ f] k_\ _fj\ dljk Y\ ]Xjk\e\[ n`k_ X _fj\ ZcXdg4 Hfj\ Hfj\ ZcXdg Oc\Xj\ Xggcp k_\ _fj\ fe _fi`qfekXc gXik IejlcXk`fe ki\Xkd\ek@ ViXg k_\ _fj\ Xe[ `kj ZcXdg lek`c kf k_\ `e[ffi le`k n`k_flk Xep Zc\XiXeZ\ n`k_ `ejlcXk`e^ dXk\i`Xc2 Xj j_fne `e k_\ ]`^li\4 RlYj`[`Xip `ejlcXk`fe* DiX`e Zfe]`idXk`fe IejlcXk`fe Q`^`[ OUC g`g\ Dli`e^ ki`Xc ile2 Z_\Zb k_Xk k_\i\ `j ef c\XbX^\ Xk k_\ g`g\ Zfee\Zk`fe gXik [li`e^ nXk\i [iX`e`e^ \m\e `e n`ek\i4 AccfnXYc\ g`g\ c\e^k_ Xe[ [ifg S_\j\ gXiXd\k\ij [`]]\i XZZfi[`e^ kf k_\ flk[ffi le`k4 R\\ k_\ `ejkilZk`fe dXelXc XkkXZ_\[ n`k_ k_\ flk[ffi le`k ]fi [\kX`cj4 O`g\ dXk\i`Xc Xe[ j`q\ O`g\ dXk\i`Xc O_fjg_filj [\fo`[`q\[ Zfgg\i j\Xdc\jj g`g\ /SO80 ]fi X`i Zfe[`k`fe\i O`g\ j`q\ /dd0 GXj j`[\ K`hl`[ j`[\ s784=6 s<49; Q\Z_Xi^\ f] i\]i`^\iXek S_\ i\]i`^\iXek i\Z_Xi^\ j_Xcc Y\ g\i]fid\[ Xj jg\Z`]`\[ `e k_\ `ejkXccXk`fe `ejkilZk`fej4 S_\ X[[`e^ gifZ\[li\ j_Xcc Y\ X`[\[ n`k_ X d\Xjli`e^ d\k\i ]fi X jg\Z`]`\[ Xdflek f] jlggc\d\ek\[ i\]i`^\iXek4 Q\hl`i\d\ek Lfi\ fi c\jj i\]i`^\iXek n`cc ZXlj\ Zfdgi\jjfi ]Xlck4 S_\ dflek f] k_\ X[[\[ i\]i`^\iXek j_Xcc Y\ Xj jg\Z`]`\[ `e k_\ `ejkilZk`fej4 -51- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Cfee\Zk`fe f] i\]i`^\iXek g`g\ Cfe[lZk ]cXi\[ Zfee\Zk`fe nfib kf Zfee\Zk Xcc i\]i`^\iXek g`g\j4 S_\ Zfee\Zk`fe f] `e[ffi le`k g`g\j dljk lj\ [flYc\ jgXee\ij4 S_\ `ejkXcc`e^ kfihl\ j_Xcc Y\ Xj ^`m\e `e k_\ ]fccfn`e^ kXYc\4 Cfee\Zk`e^ g`g\ IejkXcc`e^ kfihl\ N4D4/dd0 /M3d0 s<49; 774> /748b^]3d0 s784=6 :?46 /;46 b^]3d0 DflYc\3jgXee\i fg\iXk`fe UXZlld gldg`e^ V`k_ X mXZlld gldg2Zi\Xk\ mXZlld ]ifd k_\ jkfg mXcm\ f] k_\ flk[ffi le`k4 Edgkp`e^ n`k_ i\]i`^\iXek j\Xc\[ `e k_\ flk[ffi le`k `j XYjfclk\cp ]fiY`[[\e4 Ng\e Xcc mXcm\j Ng\e Xcc k_\ mXcm\j fe k_\ flk[ffi le`k4 GXj c\XbX^\ [\k\Zk`fe C_\Zb n`k_ X c\XbX^\ [\k\Zkfi fi jfXg nXk\i k_Xk `] k_\i\ `j ^Xj c\XbX^\ Xk k_\ g`g\ Zfee\Zk`fej Xe[ Yfee\kj4 IejlcXk`fe ki\Xkd\ek Ng\iXk\ `ejlcXk`fe ki\Xkd\ek fe Yfk_ k_\ ^Xj j`[\ Xe[ c`hl`[ j`[\ f] g`g\j i\jg\Zk`m\cp4 Dli`e^ Zffc`e^ fg\iXk`fe2Yfk_ k_\ c`hl`[ Xe[ ^Xj j`[\j Xi\ Zfc[ Xe[ k_lj j_Xcc Y\ `ejlcXk\[ jf Xj kf Xmf`[ [\n ^\e\iXk`fe4 S_\ `ejlcXk`e^ dXk\i`Xc Xk ^Xj j`[\ j_Xcc Y\ i\j`jkXek kf X k\dg\iXkli\ XYfm\ 786 [\^i\\4 S_\ `e[ffi le`k g`g\ Zfee\Zk`fe gXik j_Xcc Y\ `ejlcXk\[4 S_\ efkZ_ lgnXi[/AkkXZ_\[ [\kX`c m`\n0 F`\c[ g`g`e^ j`[\ Ie[ffi le`k RlYj`[`Xip `ejlcXk`fe klY\ 1??AMMJLQ =M BJGGJP0 Mf4 7 AZZ\jjfip gXikj Pkp4 V`i\ ZcXdg 8 8 H\Xk `ejlcXk`fe j_\Xk_`e^ 717 9 RZi\n ZXg 717 -52- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 6. Parts and Functions AU242FHBIA: DLU LQOHW DLU RXWOHW JULOOH FRPSUHVVRUnLQVLGH RI XQLWo VWRS YDOYH AU482FIBIA, AU48NFIBJA: DLU LQOHW DLU RXWOHW FRPSUHVVRUnLQVLGH RI XQLWo VWRS YDOYH -53- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA :J[[N\\N ]WR\8 F_RWP UX]^NZ +9RZ OUX_ MRZNL\RXW LJW KN JMS][\NM K` ][RWP \QN FI?B> K]\\XW XW \QN ZNVX\N LXW\ZXUUNZ, CYNZJ\RWP :XW\ZXU DJWNU 9RZ ?WUN\ >ZRUUN 9RZ =RU\NZ +?W[RMN XO \QN ?WUN\ >ZRUUN, CYNZJ\RWP :XW\ZXU DJWNU a ENVX\N ZNLNR^NZ b :XVYZN[[XZ @JVY c G?A<E @JVY :CAD G?A<E d CD<E9G?CB @JVY CD<E DCI<E <A<E e DX_NZ @JVY a b c d e f <VNZPNWL` [_R\LQ f Ceiling concealed unit: IDQnLQVLGHo PRWRUnLQVLGHo DLU RXWOHW JLOOH GUDLQDJH SLSH JDV SLSH OLTXLG SLSH HYDSRUDWRU -54- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Wall mounted unit: VLJQDO UHFHLYHU ZLQGRZ DLU LQOHW JULOOH 2DLH DLU ILOWHUnLQVLGHo U DLU RXWOHW JULOOH ORXYHU -55- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 7. Controller functions 7 NQ q|0xw v-,20-**x0 slM`PV sv sw sx sy sz su st ss sr a\i hj_` { z y x \onj n`hk PDQ w v s{ mqdib tr c`\gnc t{ ^gj^f m`n ndh`l mg``k ts tt tu tv tw tx ty tz ur PRO adgn`l l`m`n l`m`n u jiOjaa t s QNjiOjaa u322-, o1xw 2- 230, -,O-yy 3,|2 RNnx+.x0t230x w|1.*t7 SN^*-v~ w|1.*t7 TNn|+x0 jiOjaa w|1.*t7 UNc3+|w|27 w|1.*t7 VN\|0 y|*2x0 v*xt,|,z w|1.*t7 q{x, 2{x0x |1 2-- +3v{ w312 v-**xv2xw -, 2{x t|0 |,*x2L 2{x 5|0x v-,20-**x0 5|** 1{-5 2{|1 w|1.*t7 2- 0x+|,w 2{x31x0 2- v*xt, 2{x t|0 |,*x2N\y2x0 v*xt,|,z t,w |,12t**t2|-,L }312 .0x11 2{x t|0 y|*2x0 0x1x2 u322-,N WNm3.x0Om-y2 -.x0t2|-, w|1.*t7 XNat, 1.xxw w|1.*t7 | @ihc g-5 at, hxw at, c|z{ at, \32- YN\32- m5|,z w|1.*t7 QPNcxt*2{ 12t2x w|1.*t7 QQNa0x1{ t|0 12t2x w|1.*t7 QRNc3+|w|y7|,z 12t2x w|1.*t7 QTNix25-0~ v-,20-* w|1.*t7 QUNq-0~|,z +-wx w|1.*t7 Scf_]b[ @ihc Bcc`]b[ CY\ia]X]Zm]b[ GYUh]b[ EUb acXY cdYfUh]cb cdYfUh]cb cdYfUh]cb cdYfUh]cb cdYfUh]cb S]fY Wcbhfc``Yf QVN`*xv20|v {xt2|,z w|1.*t7 QWNj.x0t2|-, +-wx u322-, o1xw 2- 1x2 5-0~|,z +-wxZ \32-L ^--*|,zL _x{3+|w|y7|,zL cxt2|,zL at, QXNat, 1.xxw u322-, o1xw 2- 1x2 yt, 1.xxwZ g-5 at,L hxw at,L c|z{ at,L \32QYNm5|,z u322-, o1xw 2- 1x2 \32- m5|,z -0 a|6xw t|0 1x,w|,z w|0xv2|-, RPNnx+.x0t230x mx22|,z u322-, o1xw 2- 1x2 2x+.x0t230xL 2x+.x0t230x 0t,zxZ QV ^9SP ^ RQN^*-v~ u322-, o1xw 2- vt*|u0t2x 2{x 2|+x -y 2|+x0 t,w v*-v~ RRNmx22|,z u322-, o1xw 2- v-,y|0+ 2{x 2|+x -y 2|+x0 t,w v*-v~ RSNm*xx. u322-, o1xw 2- 1x2 m*xx. 12t2x RTNn|+x \w}312|,z u322-, o1xw 2- tw}312 2{x 2|+x -y 2|+x0 t,w v*-v~ RUNlx1x2 u322-, q{x, 2{x 5|0x v-,20-**x0 t..xt01 tu,-0+t* v-,w|2|-,L 31x t 1{t0.M.-|,2xw t02|v*x 2- .0x11 2{|1 u322-, 2- +t~x 2{x 5|0x v-,20-**x0 0x13+x ,-0+t* RVN\|0 a|*2x0 lx1x2 u322-, \y2x0 v*xt,|,z 2{x t|0 |,*x2L .0x11 2{|1 u322-,L 2{x 3,|2 vt, 12t02 2- -.x0t2x RWNn|+x0 u322-, o1xw 2- 1x2 2{x +-wx -y 2|+x0 RXNg-v~ 12t2x w|1.*t7 RYNcxt*2{ o1xw 2- v-,20-* 2{x zx,x0t2|,z -67zx, y3,v2|-, t,w ,xzt2|4x |-,My3,v2|-, SPNlx+-2x v-,20-* 5|,w-5 o1xw 2- 0xvx|4x 2{x 0x+-2x v-,20-* 1|z,t* QSNm*xx. 12t2x w|1.*t7 i-2xZ QNn{|1 +-wx* w-x1 ,-2 {t4x 2{x y-**-5|,z 0x*t2xw w|1.*t7 t,w y3,v2|-, w x y { ss st sv sx tx RNn{x -32w--0 3,|2 ,- -67zx,Mut0 y3,v2|-, -0 ,- ,xzt2|4x |-, 3,|2 ,- sr t{ {xt*2{ y3,v2|-, t,w {xt*2{ w|1.*t7N M]ge^l]neji jb _gj_f q{x, 230,|,z -, 2{x 3,|2 y-0 2{x y|012 2|+xL 2{x v*-v~ 1{-3*w ux vt*|u0t2xwN n{x +x2{-w -y vt*|u0t2|-, |1Z QNk0x11 G^*-v~G u322-,L 2{x ^*-v~ w|1.*t7 G \hG G khG 5|** y*t1{N RNk0x11 -0 2- tw}312 2|+xN a-0 xtv{ .0x11L 2{x 2|+x 5|** |,v0xt1x -0 wxv0xt1x Q +|,32xN dy wx.0x11|,z 2{x u322-,L 2{x 2|+x 5|** |,v0xt1x -0 wxv0xt1x 0t.|w*7N SN\y2x0 v-,y|0+|,z 2{x 2|+xL .0x11 G mx2G u322-,L G \hG -0 G khG 5|** 12-. y*t1{|,zL2{x v*-v~ 5|** uxz|, 2- 5-0~N -56- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA lxv-++x,wt2|-,1 o1x ^jjg |, 13++x0N o1x c`\n |, 5|,2x0N o1x _ls |, 1.0|,zLt323+, t,w |, wt+. v*|+t2xN a\i hj_` IQJ o,|2 12t02 k0x11 jiOjaa u322-,L 3,|2 12t021N k0x4|-31 -.x0t2|-, 12t231 t..xt01 -, w|1.*t7 Ii-2 n|+x0 1x22|,zJN k-5x0 |,w|vt2-0 *|z{21 3.N IRJ mx*xv2 -.x0t2|-, +-wx k0x11 hj_` u322-,N a-0 xtv{ .0x11L -.x0t2|-, +-wx v{t,zx1 t1 y-**-51Z \onj 6 n`hk c`\gnc 7 m`n ^gj^f 8 ndh`l \h mqdib mg``k adgn`l l`m`n l`m`n 9 \onj ^jjg _ls c`\n jiOjaa a\i o,|2 5|** 03, |, -.x0t2|-, +-wx w|1.*t7xw -, g^_Nm2-. w|1.*t7 t2 7-30 wx1|0xw +-wxN ISJ mx*xv2 2x+.N 1x22|,z k0x11 n`hk u322-, `4x07 2|+x 2{x u322-, |1 .0x11xwL 2x+.N 1x22|,z |,v0xt1x1 Q ^N dy u322-, |1 ~x.2 wx.0x11xwL 2x+.N1x22|,z 5|** |,v0xt1x /3|v~*7N `4x07 2|+x 2{x u322-, |1 .0x11xwL 2x+.N 1x22|,z wxv0xt1x1 Q ^N dy u322-, |1 ~x.2 wx.0x11xwL 2x+.N 1x22|,z 5|** wxv0xt1x /3|v~*7N o,|2 5|** 12t02 03,,|,z 2- 0xtv{ 2{x 2x+.N 1x22|,z -, g^_N ITJ at, 1.xxw 1x*xv2|-, k0x11 a\i u322-,N a-0 xtv{ .0x11L yt, 1.xxw v{t,zx1 t1 y-**-51Z @RQM q|0xw v-,20-**x0 gj hd lx+-2x v-,20-**x0 gj hd cdb cdb 5 o,|2 03,1 t2 2{x 1.xxw w|1.*t7xw -, g^_Nd, c`\n +-wxL 5t0+ t|0 5|** u*-5 -32 ty2x0 t 1{-02 .x0|-w -y 2|+x w3x 2- v-*wMw0ty2 .0x4x,2|-, y3,v2|-,N d, _ls +-wxL 5{x, 0--+ 2x+.N uxv-+x1 R ^ {|z{x0 2{t, 2x+.N 1x22|,zL 3,|2 5|** 03, |,2x0+|22xM ,2*7 t2 gjq 1.xxw 0xzt0w*x11 -y a\i 1x22|,zN IUJ o,|2 12-. k0x11 jiOjaa u322-,N j,*7 2|+x t,w 0--+ 2x+. 0x+t|,1 -, g^_N \** |,w|vt2-01 z- -32N px02|vt* y*t. v*-1x1 t32-+t2|vt**7N c|,21 q|0x v-,20-**x0 vt, +x+-0|8x xtv{ -.x0t2|-, 12t231N q{x, 12t02|,z |2 ,x62 2|+xL }312 .0x11 jiOjaa u322-, t,w 3,|2 5|** 03, |, .0x4|-31 12t231N \on \on x . * \32- 03,,|,zZ _30|,z 2{x \32- 03,,|,z +-wxL t|0 v-,w|2|-,|,z 03,,|,z t,w vt, t32-M1x*xv2 2{x v--*|,zL{xt2|,zL yt, +-wx tvv-0w|,z 2- 2{x 0--+ 2x+.x0t230xN at, 03,,|,zZ n{x \^ -,*7 {t4x t|0 13..*7 03,,|,z ,- v--*|,z t,w {xt2|,z 03,,|,z t2 2{x v-,w|2|-,L \^ vt,H2 {t4x t32- t|0 13..*7 03,,|,zL t,w vt,H2 w|1.*t7 2{x 1x22|,z 2x+.x0t230x 4t*3x -, 2{x g^_N _30|,z 2{x {xt2|,z 03,,|,zL ty2x0 12t02 2{x \^L |, -0wx0 2- .0x4x,2 v--*xw t|0L \^ vt, 12-. y-0 t 5{|*x uxy-0x 1x,w {xt2 t|0N _30|,z 2{x wx{3+|y|vt2|-, 03,,|,zL 5{x, 2{x 0--+ 2x+.N 1x22|,z 2x+.N L ,-2 1x22|,z v-,w|2|-, tvv-0w|,z 2- 2{x t|0 1.xxwN -57- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Yan Mgj_f _jlla_ngq ^abjla mn]lneic Zehal jkal]nejiC s-3 vt, *x2 3,|2 12t02 -0 12-. t32-+t2|vt**7 t2 y-**-5|,z 2|+xZ ]xy-0x 7-3 5t~x 3. |, 2{x +-0,|,zL -0 zx2 utv~ y0-+ -321|wx -0 ty2x0 7-3 yt** t1*xx. t2 ,|z{2N ndh`l jiOjaa @DAKbnal oien mn]lnB maga_n qjol `amela` jkal]neji hj`aC j.x0t2|-, +-wx 5|** ux w|1.*t7xw -, g^_Nk-5x0 |,w|vt2-0 *|z{21 3.N @EAZRTOX hj`a maga_neji k0x11 ndh`l u322-, 2- v{t,zx ndh`l +-wxN`4x07 2|+x 2{x u322-, |1 .0x11xwL w|1.*t7 v{t,zx1 t1 y-**-51Z ML MEE ML MEE hj_` a\i mqdib n`hk c`\gnc ^gj^f m`n 6 ndh`l m`n mg``k o ML \h V`Ub_ \h mx*xv2 7-30 wx1|0xw ndh`l +-wx Iji -0 jaaJ 8 7 adgn`l l`m`n ODPDQ jiOjaa 5 @FAZehal manneic k0x11 ndh` u322-,N `4x07 2|+x 2{x u322-, |1 .0x11xwL 2|+x |,v0xt1x1 QP+|,Ndy u322-, |1 ~x.2 wx.0x11xwL 2|+x 5|** v{t,zx /3|v~*7N `4x07 2|+x 2{x u322-, |1 .0x11xwL 2|+x wxv0xt1x1 QP+|,Ndy u322-, |1 ~x.2 wx.0x11xwL 2|+x 5|** v{t,zx /3|v~*7N n|+x 5|** ux 1{-5, -, g^_N d2 vt, ux tw}312xw 5|2{|, RT{-301N @GAMjibelheic qjol manneic \y2x0 1x22|,z v-00xv2 2|+xL .0x11 m`n u322-, 2- v-,y|0+ GjiG -0 GjaaG 12-.1 y*t1{|,zN n|+x w|1.*t7xwZ o,|2 12t021 -0 12-.1 t2 6 {-30 6 +|, Iji -0 jaaJN n|+x0 +-wx |,w|vt2-0 *|z{21 3.N Zj _]i_ag ZRTOX hj`a e312 .0x11 ndh`l u322-, 1x4x0t* 2|+x1 3,2|* ndh`l +-wx w|1t..xt01N \vv-0w|,z 2- 2{x 1x2|,z 2|+|,z -.x,L v*-1x 1x/3x,vxL vt, 0xt*|8x y|012 -.x, 2{x, v-*1x 2{x 3,|2 -0 y|012 v*-1x 2{x, -.x, 2{x 3,|2N QeinmJ q|0x v-,20-**x0 .-11x11x1 +x+-07 y3,v2|-,L 5{x, 31x ndh`l +-wx ,x62 2|+xL }312 .0x11 m`n u322-, ty2x0 +-wx 1x*xv2|,z |y 2|+x0 1x22|,z |1 2{x 1t+x t1 .0x4|-31 -,xN q|0x 0x+-2x v-,20-**x0 -0 0x+-2x v-,20-**x0 vt, +x+-0|8x xtv{ 5-0~|,z v-,w|2|-,N ix62 2|+x -.x, 2{x 3,|2L -,*7 ,xxw 2- .0x11 2{x jiOjaa ~x7L 2{x \^ vt, 5-0~ tvv-0w|,z 2*t12 2|+x 5-0~|,z v-,w|2|-,NIn|+|,zL m*xx.|,z t,w m5|,z +-wx ,-2 |,v*3wxwNJ a0-+ n|+|,z v*-1x 2- 2|+|,z -.x,L vt, 1x22|,z 1*xx. +-wxN k*xt1x v*-1x {xt*2{ y3,v2|-, y|012 uxy-0x 1x22|,z n|+x0L 2{x, 7-3 vt, w- 2{x ndh`l ji -.x0t2|-,Nk*xt1x w- ,-2 31x 2{x {xt*2{ y3,v2|-, 5{x, |, ndh`l ji 12t2xN -58- Commercial Air Conditioner hj_` a\i mqdib n`hk 6 ndh`l m`n jaa \h kh 8 m`n mg``k o ji c`\gnc 7 ^gj^f Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA : 9 adgn`l l`m`n ODPDQ jiOjaa 5 ndh`l jiMjaa @DAKbnal oien mn]lnB maga_n qjol `amela` jkal]neji hj`a j.x0t2|-, +-wx 5|** ux w|1.*t7xw -, g^_N k-5x0 |,w|vt2-0 *|z{21 3.N @EA Wlamm ZRTOX ^onnji nj _d]ica ZRTOX hj`a `4x07 2|+x 2{x u322-, |1 .0x11xwL w|1.*t7 v{t,zx1 t1 y-**-51Z ML mx*xv2 ji jaa MEE ML MEE V`Ub_ N @FAZeha manneic bjl ZRTOX VU k0x11 ndh` u322-,N `4x07 2|+x 2{x u322-, |1 .0x11xwL 2|+x |,v0xt1x1 QP+|,Ndy u322-, |1 ~x.2 wx.0x11xwL 2|+x 5|** v{t,zx /3|v~*7N `4x07 2|+x 2{x u322-, |1 .0x11xwL 2|+x wxv0xt1x1 QP+|,Ndy u322-, |1 ~x.2 wx.0x11xwL 2|+x 5|** v{t,zx /3|v~*7Nn|+x 5|** ux 1{-5, -, g^_Nd2 vt, ux tw}312xw 5|2{|, RT{-301N \h 0xyx01 2- +-0,|,z t,w kh 2- ty2x0,--,N @GA Zeha _jibelheic bjl ZRTOX \y2x0 2|+x 1x22|,zL .0x11 ndh`l u322-, 2- v-,y|0+NGjiG 12-.1 u*|,~|,zL q{|*x GjaaG 12t021 u*|,~|,zN n|+x w|1.*t7xwZ o,|2 12t021 t2 r{-30 r +|,N @HAZeha manneic bjl ZRTOX VPP a-**-5 2{x 1t+x .0-vxw30x1 |, Gn|+x 1x22|,z y-0 ndh`l jiGN @IAZeha _jibelheic bjl ZRTOX VPP \y2x0 2|+x 1x22|,zL .0x11 m`n u322-, 2- v-,y|0+GjaaG 12-.1 y*t1{|,zN n|+x w|1.*t7xwZ o,|2 12-.1 t2 r {-30 r +|,N Zj _]i_ag ZRTOX hj`a e312 .0x11 ndh`l u322-, 1x4x0t* 2|+x1 3,2|* ndh`l +-wx w|1t..xt01N \vv-0w|,z 2- 2{x n|+x 1x22|,z 1x/3x,vx -y ndh`l ji -0 ndh`l jaaL x|2{x0 m2t02Mm2-. -0 m2-.Mm2t02 vt, ux tv{|x4xwN -59- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA YSOOW i-2xZ ]xy-0x 31|,z 2{|1 y3,v2|-,L +312 tw}312 2{x v*-v~L -0 2{x 1*xx. y3,v2|-, 5|** ux w|1-0wx0xwN ^-+y-02tu*x m*xx. hj_` a\i mqdib \2 ,|z{2L uxy-0x z-|,z 2- uxw 7-3 vt, .0x11 w-5, 2{x mg``k u322-, -, 2{x v-,20-**x0 t,w 2{x t|0Mv-,w|2|-,x0 5|** 03, u7 2{x ; v-+y-02tu*x 1*xx.|,z +-wx 2- +t~x 7-3 1*xx. +-0x v-+y-02tu*xN k0x11 mg``k u322-, -,vx 2- +t~x 2{x t|0 v-,w|2|-,x0 {t4x jiOjaa 2{x .0xM1x2 1*xx. 2|+x Iy|012 .-5x0M-, |1 GQ{GJL 2{x 1*xx. 17+u-* 5|** t..xt0N k0x11 2|+x u322-, L 7-3 vt, 1{--1x 2{x 2|+x |, Q9X {-301N `tv{ .0x11 -y L 2{x 2|+x |,v0xt1x1O0xw3vx1 Q{-30 t,w G6{G t..xt0 |, 2{x {3+|w|27 1x22|,z t0xtL GjaaG t..xt01 |, Gndh`l jaaG w|1.*t7 t0xt t,w 2|+x0M-yy 2|+x[ .0x11 mg``k u322-, tzt|, 2- vt,vx* 1*xx. y3,v2|-,L 2{x 1*xx. 17+u-* w|1t..xt01N Ri _jjgeicB `adohe`ebqeic hj`a j,x {-30 ty2x0 1*xx.|,z -.x0t2|-, 12t02L 2{x 2x+.N |1 Q B {|z{x0 2{t, 2{x 1x22|,z -,xN \y2x0 t,-2{x0 {-30 2{x 2x+.N 0|1x1 Q B t,w 2{x, 03, v-,2|,3-31*7 y-0 t,-2{x0 V{01H t,w 2{x, v*-1xN n{x tv23t* 2x+.N |1 {|z{x0 2{t, 2{x 1x22|,z -,x 5{|v{ |1 2- .0x4x,2 y0-+ ux|,z 2-- v--* 2- 7-30 1*xx.N Ri da]neic hj`a j,x {-30 ty2x0 12t02 3.L 2{x 2x+.N wxv0xt1x R B *-5x0 2{t, 2{x 1x22|,z -,xN \y2x0 t,-2{x0 {-30 wxv0xt1x u7 +-0x R BN n{x 2x+.x0t230x 5|** t32-+t2|vt**7 0|1x u7 Q B ty2x0 t,-2{x0 S{01H -.x0t2|-,L t,w 2{x, t32-+t2|vt**7 v*-1x ty2x0 S{01H v-,2|,3-31 -.x0t2|-,N n{x tv20t* 2x+.x0t230x |1 *-5x0 2{t, 2{x 1x22|,z -,x 5{|v{ |1 2- .0x4x,2 y0-+ ux|,z 2-- {-2 2- 7-30 1*xx.N UjnaJ d, \onj +-wxL 3,|2 5|** 03, |, mg``k y3,v2|-, tvv-0w|,z 2- 2{x -.x0t2|-, +-wxN \y2x0 1x22|,z mg``k y3,v2|-,L |2 |1 y-0u|wwx, 2- vt*|u0t2x v*-v~N dy 2{x 1x2 1*xx.M2|+x w-x1 ,-2 0xtv{ X {-301L 2{x 3,|2 5|** 12-. -.x0t2|-, t32-+t2|vt**7 ty2x0 1x2 2|+x |1 v-+.*x2xN mx2 Gndh`lMjaaG y3,v2|-, y|012L 2{x, 1x2 mg``kL t,w 2{x 1*xx.M1x2 |1 .x0y-0+t,vx[ 1x2 ndh`lMji y3,v2|-, y|012L 2{x 1*xx. y3,v2|-, vt, -,*7 ux 1x2 uxy-0x ndh`lMji[ |y 1x2 2{xmg``k y3,v2|-, y|012L 2{x ndh`l y3,v2|-, vt, ,-2 ux 1x2N \y2x0 1x22|,z 1*xx. y3,v2|-,L ,-2 t**-5xw 2- tw}312 2{x v*-v~N ^t,H2 31x 2{x 0x+-2x v-,20-**x0 -.x0t2x 2{x \^N dy 1-L .*xt1x vt,vx* 2{x 1*xx. y3,v2|-, y|012N \y2x0 1x22|,z 1*xx. y3,v2|-,L vt,H2 1x2 2{x 2|+|,z y3,v2|-,N n`hk m`n m`nndib n mcon _jqi 5 \f Q {0 tu-32 S {01 mg``k loi ]`bdim mg``k tu-32 V {01 wxv0xt1x1 RB S {01 m`n ndh`l mg``k loi mnjkm wxv0xt1x RB 5 \f \h mg``k loi ]`bdim ^gj^f adgn`l l`m`n l`m`n jaa \h c`\gnc Q {0 |,v0xt1xQ B |,v0xt1x Q^ |,v0xt1x Q^ mcon _jqi m`nndib n mg``k loi mnjkm ^--*|,z +-wx cxt2 +-wx -60- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Konj lamn]ln boi_neji @nj ^a ]kkgea` bjl ] ia_amm]lq meno]nejiA J \y2x0 2{x t32-M0x12t02 y3,v2|-, |1 1x2L |y .-5x0 yt|*30x 13wwx,*7 -vv301 5{|*x 2{x t|0 v-,w|2|-,x0 |1 5-0~|,zL |2 5|** 0x13+x 2{x .0x4|-31 5-0~|,z 12t2x 5{x, 2{x .-5x0 |1 13..*|xw tzt|,N mx22|,z hx2{-wZ q{x, 2{x 0x+-2x v-,20-**x0 |1 -, Ix6v*3w|,z 2|+x0 +-wx t,w yt, +-wxJL .0x11 2{x Gmg``kG u322-, -, 2{x 0x+-2x v-,20-**x0 QP 2|+x1 5|2{|, U 1xv-,w1L t,w ty2x0 2{x u388x0 0|,z1 T 2|+x1L 2{x t|0 v-,w|2|-,x0 5|** x,2x0 2{x 12t2x -y t32-M0x12t02 y3,v2|-,N ^t,vx* hx2{-wZ k0x11 2{x Gm*xx.|,zG u322-, -, 2{x 0x+-2x v-,20-**x0 QP 2|+x1 5|2{|, U 1xv-,w1L t,w ty2x0 2{x u388x0 0|,z1 R 2|+x0L 2{x .-5x0 yt|*30x v-+.x,1t2|-, +-wx 5|** ux vt,vx**xwN i-2x1Z q{x, t .-5x0 yt|*30x 13wwx,*7 -vv301 w30|,z 2{x t|0 v-,w|2|-,x0 |1 5-0~|,z ty2x0 2{x .-5x0 yt|*30x v-+.x,1t2|-, |1 1x2L |y 2{x t|0 v-,w|2|-,x0 5|** ,-2 ux 31xw y-0 t *-,z 2|+xL .*xt1x v32 -yy 2{x .-5x0 13..*7 2- .0x4x,2 |21 -.x0t2|-, y0-+ ux|,z 0x13+xw ty2x0 2{x .-5x0 |1 13..*|xw tzt|,L -0 .0x11 2{x Gm5|2v{ j,OjyyG u322-, ty2x0 2{x .-5x0 v-+x1 tzt|,Ndy 2{x v-,20-**x0 ,- 1*xx. ~x7 L31x 2{x G15|,zG ~x7 |,12xtw 2{x G1*xx.|,zG -, 1x22|,z 2{x t32- 0x12t02 y3,v2|-,N ^-,vx0,|,z hlp \32- lx12t02 y3,v2|-, y-0 cMhlp +-wx*1 ct|x0 \32- lx12t02 y3,v2|-, 5{x, 2{x 3,|2 .-5x0 w0-.1 w-5, 13wwx,*7L 2{x 3,|2 +|v0-.0-vx11-0 5|** 12-0x 2{x .0x4|-31 5-0~|,z v-,w|2|-, t,w 5{x, 2{x .-5x0 |1 -, tzt|,L 2{x 3,|2 5|** 03, t1 2{|1 +x+-07N \32- lx12t02 y3,v2|-, |1 wx1|z,xw ut1|vt**7 -, 2{x hlp 5{-*x 1712x+L u32 |2 |1 13|2tu*x y-0 xtv{ |,w--0 3,|2 |,w|4|w3t**7N dy 1-+x -y |,w--0 3,|21 .-5x0 v32 w-5,L u32 2{x -32w--0 3,|2 t,w 2{x -2{x0 |,w--0 3,|21 12|** 5-0~L +t7ux .0-u*x+1 5|** {t..x, 13v{ t1 y0xx8|,z t2 v--*|,z +-wx t,w -4x0*-tw .0-2xv2|-, t2 {xt2|,z +-wx -, 2{-1x |,w--0 3,|21 5|2{-32 .-5x0N lxt1-, q{x, -,x -0 1-+x |,w--0 3,|21 .-5x0 w0-.1 w-5, t,w 2{x -2{x0 |,w--0 3,|21 t0x 12|** 5-0~L 2{x |,w--0 3,|21 5|2{-32 2{x .-5x0L 5|** ~xx. 2{x .0x4|-31 5-0~|,z v-,w|2|-, uxy-0x 2{x .-5x0 |1 -yyN \,w x6.t,1|-, 4t*4x ~xx.1 -.x, t2 t ~|,w -y -.x,|,z 0t2x v-,w|2|-, t1 2{x .0x4|-31 0x/3|0x+x,2L 1- 2{x0x |1 0xy0|zx0t,2 y*-5|,z |, 2{x x6v{t,zx0L u32 2{x |,w--0 yt, 12-.1 5-0~|,zN dy 2{x 3,|21 5-0~ t2 v--*|,z +-wxL 2{x |,w--0 3,|21 5|2{-32 2{x .-5x0 5|** +t7ux +t~x y0xx8|,zN dy 2{x 3,|2 5-0~1 t2 {xt2|,z +-wxL +t7ux 2{x -32w--0 3,|2 v-+.0x11-0 5|** 12-. uxvt31x -y 2{x .0x1130x -0 2x+.x0t230x .0-2xv2|-,N n{|1 |1 -30 wx1|z, ut1|vt**7 -, \32- lx12t02 y3,v2|-, v300x,2*7N ct|x0L cx0x5|2{L 1-*x+,*7 |,y-0+1 -30 v312-+x01L |,12t**x01L w|120|u32-01L x2vN pdai h]feic eimn]gg]nejiB kga]ma h]fa mola pdai nda kjpal em mdon `jpi pdandal ]lnebe_e]ggq jl ]__e`ain]ggqB nda pdjga mqmnah ei_go`eic jon`jjl oien ]i` ]gg nda ei`jjl oienm homn ^a jbbC Rb qjo `j ijn h]fa nda eimn]gg]neji ]m jol ei`e_]nejiB Q]eal pegg ijn ^a lamkjime^ga bjl ]iq klj^gah lamogneic bljh ndemC [mal M]oneji \u-32 2{x 0x+-2x v,-20-* -.x0t2|-,L tu-4x -,*7 2t~x 5|0xw 0x+-2x v-,20-**x0 t,w 0x+-2x v-,20-**x0 t1 t x6t+.*x tu-32 2{x 0x+-2x v-,20-**x0 t,w 0x+-2x 0xvx|4x0 31x +x2{-wL |2 |1 2{x 1t+x 0x+-2x v-,20-**x0 L .*xt1x 31x 0xyx0 2- tu-4x +x2{-wN i- 1*xx. y3,v2|-, 5{x, 31x 0x+-2x t,w 0x+-2x 0xvx|4x0N -61- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA K^jon da]gnd boi_neji a\i hj_` m`n mqdib c`\gnc n`hk ^gj^f m`n ndh`l mg``k ; adgn`l l`m`n l`m`n jaa \h \h jiOjaa j, 2{x Gcxt*2{G +-wxL |y 7-3 5t,2 2- 1x22|,z 2|+|,z -.x, +-wxL 1{-3*w v*-1x 2{x {xt*2{ y|012Z j, 2{x 2|+|,z -.x, +-wxL .*xt1x w-,H2 31x {xt*2{ y3,v2|-,N QNc-5 2- 31x 2{x {xt*2{ y3,v2|-, I-,*7 y-0 3,|21 5|2{ 2{|1 y3,v2|-,J \y2x0 1x2 2{x 0|z{2 y3,v2|-, +-wxL .0x11 {xt*2{ u322-,L 0x+-2x v-,20-**x0 -0 5|0x v-,20-**x0 w|1.*t71 G GL-67zx, .3+. -0 ,xzt2|4x |-, zx,x0t2-0 12t021 3. 2- t..*7 -67zx, -0 ,xzt2|4x |-, 2- |,w--0 3,|2N k0x11 2{x u322-, tzt|,L2{x 1|z, G G w|1t..M xt0xw t,w ,xzt2|4x |-, zx,x0t2-0 12-.1 5-0~|,zN \y2x0 t** {xt*2{ y3,v2|-, -y 2{x |,w--0 3,|2 ux|,z y3**7 vt,vx*xwL -67zx, .3+. 12-..xwN ^\ondjiZ q{x, 2{x 2x+.x0t230x -y 2{x -32w--0 3,|2 |1 *-5x0 2{t,BT L -67zx, .3+. |1 t32-+t2|vt**7 12-..xwL |y .0x11 {xt*2{ u322-, }312 2{x,L -67zx, .3+. v-3*w ,-2 12t02 3.N ]32 |y 2{x t|0 v-,w|M 2|-,x0 {t1 2{x ,xzt2|4x |-, y3,v2|-, 1|+3*2t,x-31L5{x, .0x11 2{x {xt*2{ u322-,L ,xzt2|4x |-, y3,v2|-, v-3*w 12|** ux -.x0t2xwN q{x, 2{x 2x+.x0t230x -y 2{x -32w--0 3,|2 |1 {|z{x0 2{t,BV L -67zx, .3+. v-3*w t32-+t2|vt**7 0x13+x 2- -67zx,M+t~x y3,v2|-,N a-0 cMhlp 5|0xw 27.x |,w--0 3,|2L 2{x 5|0xw v-,20-**x0 vt, ux +t2v{xw 5|2{ 2{x 0x+-2x v-,20-**x0 slMcWQ 2- 0xt*|8x 2{x 0x+-2x v-,20-* y3,v2|-,N ] gxy2 .|v230x |1 t 5|0xw 0x+-2x v-,20-**x0L 5{|v{ vt, ux 31xw -, mx0|x1 5|0xw v-,20-* 3,|21 Ln{x 0x+-2x v-,20-**x0 vt, ux .30v{t1xw x620t**7N q|0xw 0x+-2x ^-,20-**x0 31|,z +x2{-wZ QNo1x -,x 5|0xw 0x+-2x v-,20-**x0N mxx y|z IQJ RN\*1- vt, u37 t 0x+-2x v-,20-**x0 x620t**7L 0xt*|8x 5|0xw 0x+-2x v-,20-* K 0x+-2x v-,20-* w3t* v-,20-* +-wx1N FC\dai nda lahjna _jinljggal _]i ^a oma` ji maleam pela` lahjna _jinljggal oienm Bnd]i kga]ma klamm nda ^jnnji ?MVNO?nj _djjma nda kljcl]h jb _j`a ?K? \ K [ Z V h _ VPP n`hk ji jaa mqdib hj_` c`\gnc a\i mg``k al`mc ^gj^f m`n ndh`l cdbcOmj adgn`l hj_` l`m`n ^j_` gdbcn gj^f \onj m`n < ji a\i n`hk ljjh jaa hj_` mqdib \onj c`\gnc ^gj^f m`n ndh`l mg``k m`n < ^ ji adgn`l l`m`n l`m`n jiOjaa a\i n`hk ljjh jaa ^gj^f m`n ndh`l mg``k ^ adgn`l l`m`n l`m`n jiOjaa lx+-2x v-,20-***x0 q|0x 0x+-2x v-,20-***x0 lx+-2x v-,20-***x0 |1 t, tvvx11-07L 2- ux -0wx0xw x620t**7 -62- mqdib c`\gnc Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA o..x0 v-4x0 -y 5|0x v-,20-**x0 QN lx+-4x 3..x0 v-4x0 -y 5|0x v-,20-**x0 lx+-4x 3..x0 .t02 -y 5|0x v-,20-**x0 u7 .0x11N k^] |1 +-3,2xw -, *-5x0 .t02 -y 5|0x v-,20-**x0L ux vt0xy3* ,-2 2- wt+tzx |2N g-5x0 v-4x0 -y 5|0x v-,20-**x0 RN d,12t** 2{x 5|0xw 0x+-2x v-,20-**x0 k*xt1x w0|** 25- {-*x1 -, 2{x 5t** tvv-0w|,z 2- 2{x utv~ v-4x0 1v0x5 {-*x .-1|2|-, -y 2{x 5|0x 0x+-2x v-,20-**x0L 2{x, 120|~x 2{x 5--w u*-v~ 2- 2{x {-*x1 0x1.xv2|4x*7L 2{x, t*|z, 2{x R 1v0x5 {-*x -y 2{x 5|0x v-,20-**x0 utv~ v-4x0 2- 2{x 5--w u*-v~L yt12x, 2{x 5|0x 0x-2x v-,20-**x0 2- 2{x 5t** 31x 5--w 1v0x51N SN m5|2v{ 1x22|,z m5|2v{ u322-, mv0x5 {-*x n{x 15|2v{1 1x22|,z t1 y-**-51ZQNji RNjaa SNji TNjaa Ujna n07 t1 yt0 t1 .-11|u*x t y*t2 130ytvx y-0 |,12t**t2|-,N _-,H2 31x x6vx11|4x y-0vx 5{x, 2|z{2x,|,z 1v0x51L -0 *-5x0 .t02 +|z{2 z-2 wxy-0+xwN TN ^-,,xv2|,z +x2{-w t1 2{x y-**-5|,z v{t02 i- m7+u-* v-,2x,21 v-*-30 Q \ q{|2x -0 b0xx, QRp R ] lxw b,w S ^ sx**-5 T _ 55 ]tv~ v-4x0 -y 2{x 5|0x v-,20-**x0 ^jh o1x 1{|x*xwx 5|0x1 y-0 2x*xv-++3,|vt2|-, ux25xx, 5|0x v-,20-**x0 t,w |,w--0 3,|2[ |,w--0 3,|2 t,w -32w--0 3,|2N b0-3,w 2{x 1{|x*w -, -,x 1|wxN j2{x05|1x +|1-.x0t2|-, uxvt31x -y ,-|1x +t7 -vv30N m|z,t* 5|0x |1 1x*yM.0-4|wxw u7 31x0N m{|x*wxw 5|0x z0-3,w UN lx.*tvx 2{x 3..x0 v-4x0 -y 5|0x v-,20-**x0 ]x vt0xy3* ,-2 2- {-*w w-5, 2{x 5|0|,zN Qein QN k-5x0 13..*7 15|2v{ t,w 1|z,t* 5|0x 1{-3*w ux .0x.t|0xw u7 2{x 31x0N RN _-,H2 2-3v{ k^] 5|2{ {t,wN -63- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 7OR ]tmwhwlk jutywurrlw gbN\TQ {:3/A3 >@3AA B63 0=BB=< VnzopV B= 16==A3 B63 >@=5@/; =4 1=23 VmV^ ~63@3 6/D3 A=;3 4C<1B7=< 0CBB=<A 7< B63 s]x|+ AGAB3; C<7BA B6/B B63G /@3 <=B CA3^~63 23B/7:32 7<4=@;/B7=< 7A /A 4=::=Ej Viuzy \lhryo mztjyutU ~63@3 7A Vyprl~t+p tzyV 4C<1B7=< =< B63 ,lww xz*y~po BG>3 /<2 nlmtyp~ BG>3 7<2==@ C<7BA\B63 23B/7:32 7<4=@;/B7=< =4 B67A 4C<1B7=< >:3/A3 A33 the following. ~63@3 7A Vz-.rpy rpyp|l~tyrV 4C<1B7=< =< B67A s]x|+ AGAB3; Y7BXA =4 /< =>B7=</: >/@B AGAB3;Z^ ~63 AGAB3; 1/< 53<3@/B3 4@3A6 =FG53< B= B63 @==; A>/13 0G 7<AB/::7<5 B67A >/@B AGAB3;^ l0=CB s3/:B6 4C<1B=<Yt4 B63 C<7B 6/A B63 4C<1B7=< =4 0=B6 Vyprl~t+p tzyV /<2 Vz-.rpy rpyp|l~tyrVZ l4B3@ A3B B63 @756B 4C<1B7=< ;=23\>@3AA 63/:B6 0CBB=<\@3;=B3 1=<B@=::3@ 27A>:/GA V V\<=E B63 7<2==@ C<7B >=E3@ :/;> BC@<A 4=@; =@/<53 1=:=@ B= 5@33< 1=:=@\=FG53< >C;> =@ <35/B7D3 7=< 53<3@/B=@ AB/@BA C> B= />>:G =FG53< =@ <35/B7D3 7=< B= 7<2==@^ {@3AA B63 0CBB=< /5/7<\B63 A75<V V27A/>>3/@32 /<2 <35/B7D3 7=< 53<3@/B=@ AB=>A E=@97<5^/4B3@ /:: 63/:B6 4C<1B7=< =4 B63 7<2==@ C<7B 037<5 4C::G 1/<13:32\=FG53< >C;> AB=>>32^ l0=CB s3/:B6 4C<1B=<Y=<:G 6/A =FG53< >C;> 4/<1B=<Zj l4B3@ A3B B63 @756B 4C<1B7=< ;=23\>@3AA 63/:B6 0CBB=<\@3;=B3 1=<B@=::3@ 27A>:/GA V V\<=E B63 7<2==@ C<7B >=E3@ :/;> BC@<A 4=@; =@/<53 1=:=@ B= 5@33< 1=:=@\=FG53< >C;> 53<3@/B=@ AB/@BA C> B= />>:G =FG53< B= 7<2==@^ {@3AA B63 0CBB=< /5/7<\B63 A75<V V27A/>>3/@32 ^/4B3@ /:: 63/:B6 4C<1B7=< =4 B63 7<2==@ C<7B 037<5 4C::G 1/<13:32\=FG53< >C;> AB=>>32^ `adZU[uw yol ptkuuw fhrr _uztylk htk Xhiptly ztpyx }=;3 4C<1B7=<A =4 B67A 1=<B@=::3@ ;/G03 <=B /D/7:/0:3 /11=@27<5 B= B63 1=@@3A>=<27<5 {nmXA 4C<1B7=<A\AC16 /A h aa ad af ag ba bc bd bh bi ca cb cc E6716 /@3 =>B7=</: 4=@ 27443@3<B C<7B^ `adZU[uw yol Xut{lwypirl htk Xhxxlyyl htk jutxurl ptkuuw ztpyx }=;3 4C<1B7=<A =4 B67A 1=<B@=::3@ ;/G03 <=B /D/7:/0:3 /11=@27<5 B= B63 1=@@3A>=<27<5 {nmXA 4C<1B7=<A\AC16 /A e h aa ad af ag ba bc bd bh bi ca cb cc E6716 /@3 =>B7=</: 4=@ 27443@3<B C<7B^ `adZU[uw yol Yzjy htk Xlprptn jutjlhrlk ptkuuw ztpyx }=;3 4C<1B7=<A =4 B67A 1=<B@=::3@ ;/G03 <=B /D/7:/0:3 /11=@27<5 B= B63 1=@@3A>=<27<5 {nmXA 4C<1B7=<A\AC16 /A b e h aa ad af ag ba bc bd bh bi ca cb cc E6716 /@3 =>B7=</: 4=@ 27443@3<B C<7B^ -64- Commercial Air Conditioner |3;=B3 1=<B@=::3@ bh bg bi bf c` ca be ml cb bd bc cc cd ce cf a d e f g h ba b` ai ~px{ zy b c bb V e d a a[[ },tyr zqq ah qly xzop }wpp{ ag splw~s q|p}s af nwznv }p~ ~txp| strs_}z ae ad qtw~p| |p}p~ nzop ac wtrs~ wznv ab i aa a` a^~px{ }3BB7<5 mCBB=< Y*A32 B= A3B B3;>3@/BC@3^ }3BB7<5 @/<53Aj af n B= c` nZ b^},tyr mCBB=< t4 G=C >@3AA B67A 0CBB=< =<13\ /CB= AE7<5 E7:: 03 /1B7D/B32^ t4 G=C >@3AA B67A 0CBB=< /5/7<\ B63 :=CD3@ E7:: 47F 7< B63 >@3A3<B >=A7B7=<^ c^{=E3@ zy_zqq mCBB=< *A32 4=@ C<7B AB/@B /<2 AB=> l4B3@ >=E3@ =<\ B63 wno =4 @3;=B3 1=<B@=::3@ E7:: 27A>:/G B63 >@3D7=CA =>3@/B7=< AB/B3 Y3F13>B 4=@ ~txp|\}wpp{ /<2 },tyr AB/B3Z^ d^z>3@/B7=< xzop *A32 B= A3:31B =>3@/B7=< ;=23^ pD3@G B7;3 G=C >@3AA xzop 0CBB=<\ =>3@/B7=< ;=23 16/<53A /11=@27<5 B= 4=::=E7<5 A3?C3<13j dol mztjyput um jukl W nzzw o|. spl~ e^splw~s mCBB=< f^nwznv mCBB=< *A32 B= A3B 1=@@31B B7;3^ g^~txp| mCBB=< *A32 B= A3:31B ~txp| ;=23j~txp| zy\~txp| zqq^ Yy=B3j 74 B7;3 =4 ~txp| zy 7A B63 A/;3 /A ~txp| zqqZ Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA h^ qtw~p| mCBB=< *A32 B= A3B C>_2=E< 4C<1B7=< =4 47:B3@^ i^nzop mCBB=< *A32 B= A3:31B n=23 l =@ m\ B67A ;/<C/: 7A 4=@ 1=23 m^ a`^|p}p~ mCBB=< {@3AA B67A 0CBB=< 0G CA7<5 / A6/@> /@B71:3 B= @3AC;3 B63 1=@@31B =>3@/B7=< =4 B63 @3;=B3 1=<B@=::3@ 7< 1/A3 =4 <332\ 7^3^ 4=@ 3F/;>:3 7< 1/A3 =4 ;/:4C<1B7=<A 2C3 B= 3:31B@=;/5<3B71 27ABC@0/<13^ aa^wtrs~ mCBB=< *A32 B= :756B B63 1=<B@=: >/<3: Y=<:G 4=@ 1/07<3B C<7BZ ab^wznv mCBB=< *A32 B= :=19 =>3@/B7=< 0CBB=< /<2 wno 27A>:/G 1=<B3<BAj 0G >@3AA7<5 B67A 0CBB=<\ =B63@ 0CBB=<A 1=;3A =CB =4 4C<1B7=< /<2 :=19 AB/B3 27A>:/G />>3/@Ak 74 G=C >@3AA 7B /5/7<\ :=19 AB/B3 E7:: 03 <= ;=@3 /1B7D3 /<2 :=19 AB/B3 27A>:/G E7:: 27A/>>3/@^ ac^sz*| l28CAB;3<B *A32 B= A3B 1:=19 /<2 B7;3@ A3BB7<5 ad^strs_}z mCBB=< *A32 B= A3:31B strs =@ }zq~ =>3@/B7=<^ ae^}p~ mCBB=< *A32 B= 1=<47@; ~txp| /<2 nwznv A3BB7<5A E63< =@ 1==:7<5_63/B7<5 af^q|p}s mCBB=< *A32 B= A3B 4@3A6 ;=23\ B63 C<7B E7:: 2@/E 7< 4@3A6 /7@^ ag^}wpp{ mCBB=< Y~63 1:=19 ;CAB 03 1=@@31B32 034=@3 A3BB7<5 A:33> 4C<1B7=<Z *A32 B= A3B A:33> ;=23^ ah^qly mCBB=< *A32 B= A3:31B 4/< A>332jwz,\xto\strs\l*~z^ ai^~txp| zqq o7A>:/G b`^~txp| o7A>:/G ba^qtw~p| o7A>:/G ,63< B63 47:B3@ <332 03 1:3/<32\ B63 A75< E7:: />>3/@ /CB=;/B71/::G^ bb^~px{p|l~*|p o7A>:/G bc^l*~z },tyr o7A>:/G bd^stry_}z |C< o7A>:/G be^n=23 l 27A>:/G bf^}trylw }pyotyr o7A>:/G bg^n=23 m 27A>:/G bh^q@3A6 o7A>:/G bi^lCF7:7/@G pwpn~|tnlw spl~tyr o7A>:/G c`^splw~s o7A>:/G o7A>:/GA E63< 63/:B6G @C< 4C<1B7=< 7A A3B^ ca^z>3@/B7=< xzop o7A>:/G cb^}wpp{ }B/B3 o7A>:/G cc^ml~~p|. p<3@5G o7A>:/G y=B74G B63 CA3@ E63< 7B 7A B7;3 B= 16/<53 B63 0/BB3@73A^ cd^wznv }B/B3 o7A>:/G ce^qly }{ppo o7A>:/G V e d a wz, -65- xto strs l*~z Commercial Air Conditioner cf^~txp| zy o7A>:/G |3;=B3 n=<B@=::3@ z>3@/B7=< ,63< 7< CA3\ 27@31B A75</: B@/<A;7AA7=< 63/2 B= B63 @3137D3@ >:/132 =< B63 7<2==@ C<7B ~63 27AB/<13 03BE33< B63 @3;=B3 1=<B@=::3@ /<2 B63 @3137D3@ A6=C:2 03 ;/F g; /<2 B63@3 A6=C:2 03 <= =0AB/1:3 03BE33< B63;^ o= <=B B6@=E B63 @3;=B3 1=<B@=::3@k >@3D3<B 7B 4@=; 037<5 2/;/532^ ,63< =>3@/B7<5 B63 @3;=B3 1=<B@=::3@ 7< /< /@3/ E63@3 3:31B@=<71/::G 1=<B@=::32 :756BA /@3 7<AB/::32 =@ E7@3:3AA 6/<2A3BA /@3 CA32\ >:3/A3 ;=D3 1:=A3@ B= B63 7<2==@ C<7B /A B63 4C<1B7=< =4 B63 @3;=B3 1=<B@=::3@ ;756B 03 /4431B32 0G A75</:A 3;7BB32 0G B63 /0=D3 ;3<B7=<32 3?C7>;3<BA^ m/BB3@G :=/27<5 m/BB3@G :=/27<5 m/BB3@73A /@3 47BB32 /A 4=::=EAj Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA blvrhjptn yol ihyylw} jusvhwyslty rpk ~63 0/BB3@G 1=;>/@B;3<B :72 7A @37<AB/::32 7< B63 @3D3@A3 A3?C3<13^ Ypxvrh} wl{pl| {@3AA B63 0CBB=< B= A33 74 0/BB3@73A /@3 >@=>3@:G 47BB32^ t4 <= 27A>:/G />>3/@A\ @347B B63 0/BB3@73A^ Xutmpwshyput ptkpjhyuw t4 <= 7<271/B7=< 7A 27A>:/G32 /4B3@ >@3AA zy_zqq 0CBB=<\ @3:=/2 B63 0/BB3@73A^ t4 B63 @3;=B3 1=<B@=::3@ 2=3A <=B =>3@/B3 /A 23A75<32 /4B3@ 47BB7<5 <3E 0/BB3@73A =4 B63 A/;3 BG>3\ >@3AA B63 |3A3B 0CBB=< Y;/@932 Z E7B6 / >=7<B32 /@B71:3^ y=B3j + tB 7A @31=;;3<232 B6/B B63 0/BB3@73A 03 @3;=D32 4@=; B63 1=;>/@B;3<B 74 B63 @3;=B3 1=<B@=::3@ 7A <=B CA32 4=@ /< 3FB3<232 >3@7=2^ ~63 @3;=B3 1=<B@=::3@ 7A >@=5@/;;32 4=@ /CB=;/B71 B3AB =4 =>3@/B7=< ;=23 /4B3@ B63 0/BB3@73A /@3 @3>:/132^ |3;=D3 B63 0/BB3@G 1=;>/@B;3<B ,63< B63 B3AB 7A 1=<2C1B32\ /:: 71=<A E7:: />>3/@ =< :72 }:756B:G >@3AA /<2 27A3<5/53 B63 0/BB3@G B63 A1@33< /<2 B63< 27A/>>3/@ 74 B63 0/BB3@73A /@3 1=;>/@B;3<B :72 ;/@932 E7B6 V V /<2 B63< 6=:2 B63 >@=>3@:G 47BB32^ @3;=B3 1=<B@=::3@ 0G B63 C>>3@ A31B7=< /<2 B63< @3;=D3 ,63< B63 27A>:/G 031=;3 E3/9\ B67A 27A>:/G <= B63 0/BB3@G 1=;>/@B;3<B :72 0G >@3AA7<5 7< B63 27@31B7=< >=E3@ 7< B63 0/BB3@G\ >:3/A3 16/<53 B63 0/BB3@G^ - - + =4 B63 /@@=E /A A6=E< 7< B63 475C@3 /0=D3^ ^uhkptn yol ihyylw} p<AC@3 B6/B 0/BB3@73A /@3 1=@@31B:G >:/132 7< B63 1=;>/@B;3<B /A @3?C7@32 4=@ >=A7B7D3 /<2 <35/B7D3 B3@;7</:A^ Xrujq cly ,63< C<7B 7A AB/@B32 4=@ B63 47@AB B7;3 /<2 /4B3@ @3>:/17<5 0/BB3@73A 7< @3;=B3 1=<B@=::3@\ 1:=19 A6=C:2 03 /28CAB32 /A 4=::=EAj a^{@3AA nwznv 0CBB=<\ 1:=19 7<271/B7=< =4 V lx V =@ V {x V 4:/A63A^ b^{@3AA =@ B= A3B 1=@@31B B7;3^ p/16 >@3AA E7:: 7<1@3/A3 =@ 231@3/A3 a ;7<^ t4 B63 0CBB=< 7A 93>B >@3AA32\ B7;3 E7:: 7<1@3/A3 =@ 231@3/A3 ?C719:G^ c^l4B3@ B7;3 A3BB7<5 7A 1=<47@;32\ >@3AA V}p~V j lx =@ {x AB=> 4:/A67<5\ E67:3 1:=19 AB/@BA E=@97<5^y=B3jlx ;3/<A ;=@<7<5 /<2 {x ;3/<A /4B3@<==<^ xzop }wpp{ splw~s q|p}s nwznv }p~ 0 / ~txp| strs_}z 1 qtw~p| |p}p~ wtrs~ nzop wznv Xaa^ M \ZVd htk Ybg avlwhyput m a^ *<7B AB/@B {@3AA zy_zqq 0CBB=<\C<7B AB/@BA^ {@3D7=CA =>3@/B7=< AB/BCA />>3/@A =< wno Y3F13>B 4=@ ~txp|\ }wpp{ /<2 },tyr A3BB7<5Z b^}3:31B =>3@/B7=< ;=23 {@3AA xzop 0CBB=<^ lB 3/16 >@3AA\ =>3@/B7=< ;=23 16/<53A /A 4=::=EAj 4=::=EAj V e d a ~px{ zy zqq },tyr xzop 3 splw~s nzzw ~63< A3:31B nzzw o|. spl~ =>3@/B7=< =@ A3:31B o|. =>3@/B7=< =@ A3:31B spl~ =>3@/B7=< qly }wpp{ q|p}s nwznv }p~ ~txp| strs_}z qtw~p| |p}p~ -66- / nzop wtrs~ wznv 2 Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA c^~3;>3@/BC@3 A3BB7<5 {@3AA ~px{ 0CBB=<^ pD3@G B7;3 B63 0CBB=< 7A >@3AA32\ B3;>^ A3BB7<5 7<1@3/A3A a235@33^ t4 0CBB=< 7A 93>B 23>@3AA32\ B3;>^ A3BB7<5 E7:: 7<1@3/A3 ?C719:G^ pD3@G B7;3 B63 0CBB=< 7A >@3AA32\ B3;>^ A3BB7<5 231@3/A3A a235@33^ t4 0CBB=< 7A 93>B 23>@3AA32\ B3;>^ A3BB7<5 E7:: 231@3/A3 ?C719:G^ }3B >@=>3@ B3;>3@/BC@3 d^l28CAB qly 0CBB=< {@3AA qly 0CBB=<^ lB 3/16 >@3AA\ 4/< A>332 16/<53A /A 4=::=EAj V e d a wz, xto strs l*~z l7@ 1=<27B7=<3@ E7:: @C< /B B63 A3:31B32 4/< A>332^ e^ *<7B AB=> {@3AA zy_zqq 0CBB=<\ C<7B AB=>A nzzw =>3@/B7=< AB/@BA E63< @==; B3;>^7A 67563@ B6/< B3;>^A3BB7<5^ *:B@/]:=E /7@ 4:=E t< spl~ ;=23\E/@; /7@ E7:: 0:=E =CB /4B3@ / A6=@B >3@7=2 =4 B7;3 2C3 B= /<B7]1=:2 4C<1B7=<^ ~3;>^ A3BB7<5 [b n z< @3/167<5 B3;>^ A3BB7<5 [b n\ C<7B E7:: @C< 7< ;7:2 o|. ;=23^ dpslw a`Pa[[ [ztjyputMKcly jrujq juwwljyr} ilmuwl xyhwyptn d]_Zb uvlwhyputL m a[[ ~px{ zy zqq },tyr xzop splw~s / qly dpslw a`Na[[ [ztjyput a^*<7B AB/@B l4B3@ C<7B AB/@BA\A3:31B G=C@ 23A7@32 =>3@/B7=< ;=23Yz>3@/B7=< ;=23 E7:: 03 27A>:/G32 =< wnoZ b^~txp| ;=23 A3:31B7=< {@3AA ~txp| 0CBB=< =< B63 @3;=B3 1=<B@=::3@ B= 16/<53~txp| ;=23^ pD3@G B7;3 B63 0CBB=< 7A >@3AA32\27A>:/G =4 ~txp| ;=23 16/<53A /A 4=::=EAj +* +~~ 0:/<9 }wpp{ ~txp| zy ~txp| zqq q|p}s nwznv }p~ ~63< A3:31B ~txp| ;=23 /A <33232 c^~7;3 A3BB7<5 3 5 {@3AA B7;3 0CBB=< pD3@G B7;3 B63 0CBB=< 7A >@3AA32\B7;3 7<1@3/A3A /< 6=C@^t4 B63 0CBB=< 7A 93>B >@3AA32\B7;3 E7:: 16/<53A ?C719:G^ pD3@G B7;3 B63 0CBB=< 7A >@3AA32\B7;3 231@3/A3A /< 6=C@^t4 B63 0CBB=< 7A 93>B >@3AA32\B7;3 E7:: 16/<53A ?C719:G^tB 1/< 03 /28CAB32 E7B6 7< ab 6=C@A /B E7::^ lx @343@A B= ;=@<7<5 /<2 {x @343@A B= /4B3@<==<^ d^~7;3@ 1=<47@;7<5 l4B3@ B7;3 A3BB7<5 \>@3AA }p~ 0CBB=< B= 1=<47@; B7;3^ e^n/<3: ~txp| ;=23 uCAB >@3AA ~txp| 0CBB=< A3D3@/: B7;3A C<B7: ~txp| ;=23 27A/>>3/@A^ l11=@27<5 B= B63 B7;3 A3BB7<5 A3?C3<13 =4 ~txp| zy /<2 ~txp| zqq\ 37B63@ AB/@B]AB=>A =@ AB=>A]AB/@B 1/< 03 @3/:7H32^ | ~txp| 2 qtw~p| |p}p~ nzop | 0 tr 4 1sstrs_}z qtw wtrs~ wznv l4B3@ @3>:/17<5 0/BB3@73A =@ 74 />=E3@ 4/7:C@3 =11C@A\~txp| A3BB7<5 ;CAB 03 @3A3B^ |3;=B3 1=<B@=::3@ 6/A ;3;=@G 4C<1B7=<^,63< G=C CA3 ~txp| ;=23 <3FB B7;3\8CAB >@3AA }p~ 0CBB=< /4B3@ ;=23 A3:31B7=< 74 B7;3@ A3BB7<5 7A B63 A/;3 /A B63 >@3D7=CA =<3^ -67- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA \lhryo J [wlxo Vpw uvlwhyput \lhryo uvlwhyput l4B3@ BC@<7<5 =< B63 C<7B /<2 A3B B63 23A7@32 E=@97<5 ;=23^ {@3AA B63 s3/:B6 0CBB=<\B63 wno E7:: 27A>:/GV V\B63 C<7B 0357<A 63/:B6 =>3@/B7=<YAB/@B B63 <35/B7D3 7=< 53<3@/B7=< 23D713Z^{@3AA B63 s3/:B6 0CBB=< /5/7<\B63 V V27A>:/G32 =< B63 wno 27A/>>3/@A\63/:B6 =>3@/B7=< 7A 1/<13::32YBC@< =44 B63 <35/B7D3 7=< 53<3@/B7=< 23D713Z^ m V e d a y=B3j,63< 7<2==@ 4/< ;=B=@ 2=3A <=B E=@9\B63 C<7B E7:: /CB=; /B71/::G BC@< =44 <35/B7D3 7=< 53<3@/B7 =< 23D713^ ~px{ zy zqq },tyr qly }wpp{ xzop splw~s nwznv / q|p}s 0 }p~ ~txp| strs_}z qtw~p| |p}p~ nzop wtrs~ wznv Viuzy \lhryo uvlwhyput l4B3@ B63 AB/@B =4 63/:B6 =>3@/B7=<\B63 <35/B7D3 7=< 53<3@/B=@ E7:: 53<3@/B3 :/@53 /;=C<B =4 <35/B7D3 7=<\E6716 1/< 34431B7D3:G 0/:/<13 B63 /;=C<B =4 >=A7B7D3W <35/B7D3 7=< 7< B63 /7@ /<2 6/A B63 0/1B3@7/]97::7<5 /<2 /113:3@/B7<5 B63 2CAB 23>=A7B7=< =4 B63 @==; B= ;/93B63 @==; /7@ 4@3A6 /<2 63/:B6G^ q@3A6 l7@ =>3@/B7=< l4B3@ BC@<7<5 =< B63 C<7B /<2 A3B B63 23A7@32 E=@97<5 ;=23YB63 @3;=B3 1=<B@=::3@ wno /<2 1=<B@=: >/<3: wno 27A>:/G B63 E=@97<5 ;=23Z^ {@3AA B63 q@3A6 /7@ 0CBB=< =4 B63 @3;=B3 1=<B@=::3@\B63 wno 27A>:/GAV V\/<2 B63 C<7B 0357<A 1=<B7<C=CA 4@3A6 /7@ =>3@/B7=<k>@3AA B63 0CBB=< /5/7<\B63V V7< V V4:/A63A /<2 0357< /CB=;/B71 4@3A6 /7@ =>3@/B7=<^>@3AA B63 0CBB=< 4=@ B63 B67@2 B7;3 B= 1/<13: 4@3A6 /7@ 4C<1B7=<^ n=<B7<C=CA 4@3A6 /7@ =>3@/B7=<j~6/B 7A B= A/G\74 B63@3 7A <= 7<B3@D3<B7=<\B63 4@3A6 /7@ =>3@/B7=< E7:: 1=<B7<C=CA:G @C< /<2 <=B AB=>^ lCB=;/B71 4@3A6 /7@ =>3@/B7=<j~6/B 7A B= A/G\B63 4@3A6 /7@ =>3@/B7=< @C<A 7<B3@;7BB3<B:G^l4B3@ b` ;7<CB3A =>3@/B7=<\B63 4@3A6 /7@ =>3@/B7=< E7:: AB=> 4=@ b` ;7<CB3Ak@C<A 4=@ /<=B63@ b` ;7<CB3A\7B E7:: AB=> 4=@ /<=B63@ b` ;7<CB3A\@3>3/B32:G @C<A^ y=B3jp7B63@ 7< zy =@ zqq AB/B3\B63 4@3A6 /7@ =>3@/B7=< 1/< 03 7<23>3<23<B:G A3B B= @C<^ Viuzy [wlxo hpw uvlwhyput ~63 D3<B7:/B7=< 23D713 =4 B67A /7@ 1=<27B7=<3@ 1/< 27A16/@53 B63 7<2==@ /7@ B= =CB2==@A\E67:3 B63 =CB2==@ 4@3A6 /7@ AC>>:3;3<B B= 7<2==@A\A= B6/B 4C:47::A B63 4@3A6 /7@ 4C<1B7=<^ -68- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 7 NS lx+-2x 0xvx|4x0 l`MPQ dy 2{x 3,|2 |1 5|0xw 27.x t,w |2 |1 5|2{-32 2{x 0x+-2x 0xvx|4x0L 7-3 vt, 31x 2{x 0x+-2x 0xvx|4x0 l`MPQ t,w 2{x 0x+-2x v-,20-**x0 slMcWQ 2- 0xt*|8x 2{x 0x+-2x y3,v2|-,N n{x |,12t**t2|-, -y 0x+-2x 0xvx|4x0 t,w 31tzx y3,v2|-, t0x t1 y-**-51Z n{x 0|z{2 y|z30x |1 t 0x+-2x v-,20-**x0L 5{|v{ vt, ux 31xw -, 1x0|x1 0x+-2x v-,20-* 3,|21 t,w 2{x +t2v{|,z 0x+-2x v-,20-* 0xvx|4x0 QNlx+-2x v-,20-* 0xvx|4x0 31|,z +x2{-w Z o1x 0x+-2x v-,20-**x0 v-,20-* 2{x 0x+-2x v-,20-* 5|,w-5 -y 2{x 0x+-2x v-,20-* 0xvx|4x0N ECYaleam lahjna _jinljggal oienm kga]ma klamm nda ji jaa ^jnnji ?MVNO?nj _djjma nda kljcl]h jb _j`a ?L? ] \ K [ Z V h _ VPP n`hk mqdib a\i mg``k hj_` c`\gnc al`mc ^gj^f m`n ndh`l cdbcOmj adgn`l l`m`n ^j_` gdbcn gj^f lx+-2x 0xvx|4x0 lx+-2x v-,20-***x0 d,12t**t2|-, -y 0xvx|4x w|1.*t7 ]xvt31x -y 2{x 2x+.x0t230x 1x,1|2|4x wx4|vxL w- ,-2 |,12t** 2{x 0xvx|4x w|1.*t7 t2 120t|z{2 13,*|z{2 .*tvxL x|2{x0 |, y0-,2 -y t|0 -32*x2 z0|**L y-0 |2 |1 xyyxv2xw z0xt2*7 y0-+ v--* t|0 t,w {xt2 t|0L 2{x 0xvx|4x w|1.*t7 |1 t2 *xt12 RP++ w|12t,vx 2- 2{x t|0 -32*x2 z0|**N m|,vx 2{x0x |1 *|z{2 1x,1|2|4x wx4|vx 5{|v{ 0xvx|4x1 5|0x*x11 0x+-2x 1|z,t*L 1- w- ,-2 |,12t**xw ux{|,w 2{x 5|,w-5 v302t|, -0 -2{x0 -u12tv*x1L |, -0wx0 ,-2 2- -u1203v2 2{x 1|z,t*N h312 y|6 2{x 0x+-2x v-,20-* 5|0x yt0 y0-+ 120-,z x*xv20|v|27 I13v{ t1 2{x 5|0|,z -y x*xv20|v *|z{2L t|0 v-,wM |2|-,x0L x2vNJ t,w 5xt~ x*xv20|v|27 I13v{ t1 2{x 5|0|,z -y 2x*x.{-,xL |,2x0.{-,xL x2vNJN QNa|6 2{x 0xvx|4x w|1.*t7 5|2{ 1v0x51 -, 2{x 1x*xv2xw .*tvx ^-,,xv2|,z 5|0|,z +x2{-w -y 0xvx|4x0 Z lxyx0 2{x |,w--0 3,|2 5|0|,z w|tz0t+ N mtyx27 vt32|-,1 1xx 2{x x*xv20|vt* 5|0|,z .t02 N RNk*tvx 2{x .t,x* -,2- 2{x y|6xw y0t+xL .t7 t22x,2|-, 2{t2 2{x y-30 v*t51 +312 ux .*tvxw |,2- 2{x v-00x1.-,w|,z y-30 .-*x1 -, 2{x y0t+x Q N`+x0zx,v7 15|2v{ R Nl3,,|,z *t+.Z q{x, 2{x v-+.0x11-0 5-0~|,zL 2{|1 *t+. u0|z{2N S Nn|+|,z *t+.Z q{x, 2{x 3,|2 uxx, 1x22|,z n|+|,z 03,,|,zL 2{|1 *t+. u0|z{2N T Nk-5x0 *t+.Z \y2x0 -.x, 2{x 3,|2L 2{|1 *t+. u0|z{2 5{x, 2{x 3,|2x x,2x0 {xt*2{ 03,,|,zL 2{x *t+. v{t,zx y0-+ -0t,zx 2- u*3x *t+.N U Nd,w--0 2x+.N 1x,1-0Z nx12 2{x 0--+ 2x+.x0t230xN -69- 9 6 8 7 5 Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 7 vy {**/+00 0+1 ~.-1/.,,+/ {}|uwx 20 AYU_UMW OZYYQO_UZY ZR [ZbQ] ^`[[Wd JT]QQ ^QOZYP^ MR_Q] _TQ ]QXZ_Q OZY_]ZWWQ] U^ OZYYQO_QP _Z [ZbQ] ^`[[Wd.PQRM`W_ ^dXNZW +2+ ZR _TQ `YU_ XZPQW bUWW NQ PU^[WMdQP ZY _TQ C<= MYP _TQ YQb UOZY + + ^TMWW NQ _]MY^XU__QP0 30 F[Q]M_UZYZR ]QXZ_QOZY_]ZWWQ] JTQ I>C><J ;`__ZY 9JTQ UOZY + + U^ PU^[WMdQP bTQY _TQ N`__ZYU^ RU]^_ []Q^^QP MYP _TQ R`YO_UZY RZ] _]MY^XU^^UZY ZR []QaUZ`^Wd ^Q_ OZPQ U^ ^Q_0 AR _TQ ^MXQ N`__ZY U^ []Q^^QP MSMUY. _TQ UOZY + + M[[QM]^ RZ] ^Q__UYS ZR YQb OZPQ0 JTQ R`YO_UZY UOZY bUWW NQ ^bU_OTQP RZ] PU^[WMd UR _TQ N`__ZY U^ OZY_UY`Z`^Wd []Q^^QP0 JTQ +HQMP+ N`__ZY9 G]Q^^UYS ZR _TU^ N`__ZY bUWW ]Q^`W_ UY ^UX`W_MYQZ`^ PU^[WMdZR PQT`XUPURdUYS MYP _]MY^XU^^UZY UOZY^ ,NWMOV bM_Q] P]Z[ MYP [d]MXUP M^ ^TZbY UY_TQ RUS`]QJTQ CZOV N`__ZY9 JTU^N`__ZY OMYNQ []Q^^QP MR_Q] YQbOZPQ _]MY^XU^^UZYU^ ^Q_0LTQY _TQ N`__ZY U^ []Q^^QP._ TQ UOZY+FRR+ M[[QM]^ZY _TQC<=. _TQY QcOQ[_ _TQ HQMPUYS N`__ZY. MWW _TQ N`__ZY^ bUWW NQ ^TUQWPQP bU_T _TQ ]QOQUaQ] OZPQ WZOVQP0 AR _TQ N`__ZYU^ []Q^^QP MSMUY. UOZY+FRR+ PU^M[[QM]^MYP _TQ WZOV/ZY R`YO_UZY U^ UYMO_UaM_QPRZ] MWW _TQ Z_TQ] N`__ZY^0 DMOTUYQ Y`XNQ] N`__ZY ,EZ02 _Z EZ06 `YU_-9 AR _TQ N`__ZY U^ []Q^^QP. M XMOTUYQ ^Q]UMW N`__ZY U^ PU^[WMdQP bU_T M RWM^TUYS R]Q\`QYOd ZR 2@e0 IQ_ XMOTUYQ Y`XNQ] 7.89 []Q^^ N`__ZY 6.MYP bU_TUY 3^QOZYP^ []Q^^ N`__ZY 2. _TQY WZZ^Q _TQX ^UX`W_MYQZ`^Wd. 7 bUWW PU^[WMd UY _TQ ^O]QQY. bTUOT ^_MYP^ RZ] ^QWQO_UYS `YU_ 70 :YP _TQY []Q^^ N`__ZY+^Q_+. dZ` OMY ^Q_ `YU_ 70JTQY []Q^^ +H>:=+ _Z OZYRU]X UR _TQ `YU_ Y`XNQ] U^ ]UST_0 LU_T _TQ ^MXQ XQ_TZP. ^Q_ `YU_ EZ080 DMOTUYQ Y`XNQ] +^Q_+ N`__ZY9 JTU^ N`__ZY OMY NQ ^Q_ bTQY XMOTUYQ Y`XNQ] RWM^TQ^ ZY _TQ C<=0 DMOTUYQ Y`XNQ] RWM^TUYS bUWW NQ ^Q_ MYP _]MY^XU__QP UR _TQ N`__ZY U^ []Q^^QP. _TQ XMOTUYQ Y`XNQ] ^_Z[^ RWM^TUYS MYP M _]MY^XU^^UZY UOZY ,_TQ NWMOV [d]MXUP ^TZbY UY _TQ RUS`]Q- bUWW M[[QM] ZY _TQ C<=0 JTQ +HQ^Q_+ N`__ZY9 AY^Q_ M [ZUY_QP _ZZW , 3XX- UY_Z _TQ TZWQ ZR _TQ HQ^Q_ N`__ZY0> aQ]d []Q^^ ZR _TQ _ZZW bUWW ]Q^Q_ _TQ QcU^_UYS ^Q__UYS. MYP _T]QQ ^QOZYP^ WM_Q]. UYU_UMW Z[Q]M_UZY XZPQ bUWW M[[QM] ZY _TQ C<=0 40 JQ^_ ZR ]QXZ_QOZY_]ZWWQ] ,UQ0 EZ0 4 `YU_G]Q^^ KYU_ 4 N`__ZY._TQ Y`XNQ] 4 RWM^TQ^ bU_T M R]Q\`QYOd ZR 2@e0 G]Q^^ _TQ XMOTUYQ Y`XNQ] ^Q_ N`__ZY. _TQ ^QWQO_QP `YU_ Y`XNQ] bUWW NQ ^Q_ MYP _]MY^XU__QP _Z _TQ ]QOQUaQ] ZR _TQ `YU_0 rns G]Q^^ _TQ HQMP N`__ZY MYP _TQ ^QWQO_QP `YU_ ^_M]_^ ]QMP _TQ ^Q_ XMOTUYQ Y`XNQ]0AR XMOTUYQ Y`XNQ] ZR ^QWQO_QP UYPZZ] opgh opgi opgj `YU_ U^ OZ]]QO_Wd PU^[WMdQP.,?WM^T Y`XNQ] ZR _TQ UYPZZ] `YU_ opgk opgl opgm [ZbQ] UYPUOM_Z] UX[WUQ^ XMOTUYQ Y`XNQ]- ^Q__UYS ZR XMOTUYQ Y`XNQ] U^ ^`OOQ^^R`W Z] aUOQ aQ]^M0 qnrns LTQY ^Q__UYS U^ OZX[WQ_QP. []Q^^ _TQ CZOV N`__ZY. ,RZ] YQb Y`XNQ] ]QXZ_Q OZY_]ZWWQ] ZYWd- MYP _TQ UOZY CZOV/ZY M[[QM]^ ZY _TQ C<=. _TQY _TQ XMOTUYQ Y`XNQ] ZR _TQ UYPZZ] `YU_ U^ WZOVQP0 K^`MWWd XMOTUYQ Y`XNQ]^ PZ YZ_ YQQP _Z NQ WZOVQP0 50 : ^WUST_ ^Z`YP XMd NQ []ZP`OQP Nd _TQ UYPZZ] `YU_ bTQY _TQ ^USYMW R]ZX _TQ ]QXZ_Q OZY_]ZWWQ] U^ ]QOQUaQP0 F?? CF<B EZ_Q9 =ZYZ_ ^Q_ XMOTUYQ Y`XNQ]^ RZ] XZ]Q _TMY ZYQ UYPZZ] `YU_ NQRZ]Q M WM[^Q ZR 31 ^QOZYP^ MR_Q] OZX[WQ_UZY ZR ^Q__UYS ZR XMOTUYQ Y`XNQ] ZR M UYPZZ] `YU_0 -70- I>C ><J Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 8. Electrical Control Functions 8.1 Outdoor control principle: No 1 Item AU242FHBIA 1. Startup period in cooling mode: high 2. Cool, Dry mode: ƽCurrent state is Fan OFF mode: TC˚21ć: low speed ƽ Current state is low speed: TC˚30ć, med speed TC˘15ć, fan off ƽ Current state is med speed: TC˚42ć, high speed TC˘22ć, low speed ƽ Current state is high speed: TC ˘ 39 Current state is Fan motor med speed: control AU482FIBIA AU48NFIBJA 1. Startup period in cooling 1. Startup period in cooling mode: mode: high TA˚16ć, high speed 2. Cool, Dry mode: ƽ Current state is Fan OFF TAİ16ć, low speed mode: 2. Cool, Dry mode: TC˚37ć: low speed ƽTA˚32ć, high speed ƽCurrent state is low speed: ƽ15ćİTA˘31ć: TC˚50ć, med speed TC˚45ć, high speed TC˘30ć, fan off 40 ć ˘ TC ˘ 44 ć , med ƽCurrent state is med speed: speed TC˚47ć, high speed TC˘39ć, low speed TC˘40ć, low speed ƽTA˘15ć: ƽCurrent state is high speed: TC˘30ć, fan off TC˘41ć, med speed TC˚50ć, low speed ƽIn low speed: ƽIn low speed: TC˘40ć, lower fan off TC˘36ć, lower fan off TC˚42ć, lower fan startup TC˚38ć, lower fan startup 1. Startup period in heating: TAı20ć, low speed 1. Startup period in heating: TA˘20ć, high speed High speed 1. Startup period in heating: 2. Running state in 2. Running state in heating:ƽ High speed heating: TA˚17ć 2. Running state in heating: ƽTA˚17ć: running units capacity İ ƽTA˚17ć running units capacityİ1 running units capacityİ 1HP, low speed will be ON HP, low speed will be ON and OFF in turns. 1HP, low speed will be and OFF in turns. ƽOther condition: ON and OFF in turns. running units capacity ˚ TE˘7ć, high speed ƽOther condition: 1HP, low speed TE˚10ć, low speed TE˘7ć, high speed ƽ 17 ć ˚ TA ˚ 15 ć , low 3. TE˚14ć, lower fan off TE˚10ć, low speed speed TE˘12, lower fan startup ƽ 14 ć ˚ TA ˚ 10 ć , med speed ƽTA˘9ć, high speed 2 EEV In COOL, DRY, DEFROST state, EEV will open fully with 480 pulse. -71- Commercial Air Conditioner control 3 4 Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA In heating mode, EEV will be adjusted due to the overheating value: SH= TS-TC 1. Adjust range: according to the compressor frequency, min open angle of EEV will be different: high frequency, 120; med frequency, 110; low frequency, 90; the max open angle: 470/350 2. Overheating modification: according to the discharging temperature, modify the overheating value, when Td>100ć, overheating value will decrease 2 at the standard overheating value; when Td İ 70 ć , overheating value will add 2 at the standard overheating value 1. Secure operation conditions of 4-way valve: ƽ After the outdoor receives the heating signal from indoor unit, if the 4-way valve is not electrified before the compressor starts up, the unit will enter the 4-way valve secure operation. ƽ After defrosting is over, the unit will enter the 4-way valve secure operation. 2. 4-way valve secure operation control: 4-way ƽ In heating mode, After the outdoor receives the startup signal from indoor unit, the valve compressor will start up, (fan motor shutoff, EEV close) and when the frequency rises up secure to 50Hz for 10 seconds, 4-way valve will reverse (meanwhile, fan motor will enter the operation target speed, EEV enters the open angle of soft startup) and the unit enters soft startup period. ƽ In defrosting, when the defrost condition is met, the compressor frequency will decrease to 50Hz, 4-way valve will reverse (meanwhile, fan motor will enter the target speed) and the unit enters soft startup period. 3. 4-way valve control in OFF state: 4-way valve will close after compressor stops for 30 minutes. 1. Enter condition: when compressor runs for 45 minutes in all in heating mode, by checking TE and TA, if the below conditions can be met for continuous 5 minutes, the unit will enter defrosting operation: TEİChTAˉ¢, herein, Defrosting ƽC˖TA˘0ć, C=0.8; TAı0ć, C=0.6 control ƽ¢˖set as 12˄L˅,10˄M˅,8˄H˅ according to the actual condition. At the easily defrosting place, set as H; at the not-easy-defrosting place, set as L; when out of factory, set as M ƽTemperature limitation: -15ćEİTEİ2ćE -72- 1. Enter condition: when compressor runs for 45 minutes in all in heating mode, by checking TE and TA, if the below conditions can be met for continuous 5 minutes, the unit will enter defrosting operation: ƽWhen Ta˘2ć, TA-TE ı9ć for continuous 2 minutes; or Te ˘ -12 ć for continuous 5 minutes; ƽWhen Taı2ć, Te˘-5 ć for continuous 5 minutes; Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 2. Defrosting control: When defrosting condition is met, compressor frequency will go down to the min. frequency, and 4-way valve will be powered off and turn into cooling mode (fan motor off, EEV in soft startup open angle); compressor frequency rises up to 78Hz and begins to defrosting operation. 3. Quit condition: ƽTE is over 7ć for 60 seconds in all or is up to 12ć, defrosting is over; ƽDefrosting accumulative time is up to 10 minutes, defrosting is over. 5 Electric heater control 1. When TAİ27ć, if the compressor stops running, electric heater will be electrified; 2. When TAı27ć, or when compressor starts up, electric heater will be off; and temp. difference is 5ć. 6 1. To balance pressure: it will open 1 minute before compressor starts up, and keep open Unloading in soft startup period after compressor starts up until the soft startup is over; in the remaining operation and 10 minutes later after shutoff, SV1 will open; valve SV1 control 2. Improve low pressure: in heating mode, when (TCǃTSǃTE)min. valueİ-13ć SV1 open, temp. difference is 3ć. 7 Spray Adjust the SV2 according to the discharging temperature: valve SV2 when TDı115ć, SV2 will open; when TDİ110ć, SV2 will close. control High pressure switch protection: ƽWhen input level of pressure switch is 1, it shows there is no protection. ƽWhen input level of pressure switch is 0 for a while, it shows high pressure beginning; compressor stops and the unit alarms. The alarm can be resumable, the unit will alarm in 3 minutes when compressor is standby. 8 Pressure Low pressure switch protection: switch ƽWhen input level of pressure switch is 1, it shows there is no protection. control ƽ When compressor is running, if low pressure switch has acted for 3 minutes continuously, the unit will alarm. When compressor stops, if low pressure switch has acted for 30 seconds continuously, the unit will alarm. When compressor starts up, low pressure switch will be shielded within 3 minutes. ƽIn defrosting and in 6 minutes after defrosting is over, low pressure switch will be shielded. -73- Commercial Air Conditioner 9 Compress or capacity output control Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA In cooling mode, frequency will be calculated according to the horse power of the running indoor units: 1. Every indoor unit will confirm 8 capacity codes according to the difference between the set temperature and the ambient temperature; then add all the capacity code of the running indoor unit. 2. Divide the outdoor capacity into 13 capacity classes due to the frequency; every capacity class is corresponding with the different indoor capacity code; modify the relative indoor capacity code due to the different ambient temperature; 3. Compressor will confirm its target frequency according to the sum of indoor capacity code; Cooling target frequency will be confirmed due to the indoor running horse power and the outdoor ambient temperature: F=C1(P-C2)+C3(T-35)+C4 Herein: C1=22, C2=160, C3=64, C4=4200; Heating target frequency will be confirmed due to the indoor running horse power and the outdoor ambient temperature: F=C1(P-C2)+C3(7-T)+C4+C5(C6-TZ) Herein: C1=16; C2=160; C3=32; C4=4500; C5=300; C6=45. -74- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 8.2 Indoor electric control functions: No 1 Control item AE*FCBKA AS*FCBHA AB*FCBIA In cooling mode, the adjustment by the over heating: SH= TC1(gas pipe)-TC2˄liquid pipe˅ 1. Adjust range: min. angle: 60/65, max. angle: 470/350˄data will take EEPROM as standard˅ 2. Overheat modification: according to the discharging temperature, modify the overheat state, if Td > 100 ć, the overheat value will add 2 degree at the base of standard degree; 3. Open modification: when EEV is at min. angle, the unit will measure the difference between Tliquid and Ta at the interval of 5 minutes, if the EEV control difference is within 5 degree, the valve will be back to base open angle and modify the open angle due to the overheat state In heating mode, adjust the open angle according to the conformity of liquid pipe temperature. 1. Adjust range: indoor unit startup, min open angle: 100, max open angle: 470; indoor unit standby: open angle: 60. 2. The indoor EEV open angle will depend on the temperature difference between indoor liquid pipe temp. and average liquid temp. of all running indoor units. (if lower than average temp., the valve will open; if high than average temp., the valve will close. 2 Anti-freeze control in cooling mode: ƔWhen liquid pipe temp. is below 7 degree for 40 minutes, or when liquid pipe temp. is below 4 degree for 10 minute, the unit will enter anti-freeze function. At this time, the current indoor EEV will close, and the fan motor will turn into low speed from the current speed. ƔAfter the anti-freeze function has worked for 10 minutes, and liquid pipe temp. is over 7 degree, the unit will quit anti-freeze control (take the data in Fan motor EEPROM as standard). control Anti-cold air control in heating mode: ƔWhen liquid pipe temp. is below 33 degree, indoor fan speed will turn into low speed from the set speed; when liquid pipe temp. is below 25 degree, indoor motor will stop. ƔWhen liquid pipe temp. is over 30 degree, indoor fan speed will turn into low speed from stop; when liquid pipe temp. is over 35 degree, indoor motor will enter the set speed (take the data in EEPROM as standard). -75- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 8.3 Temperature compensation adjustment (only for indoor unit with new PCB-AB**FCBIA): For infrared control type unit, the temperature compensation can be adjusted. But for wired control type unit, there is no temperature compensation. Set the EEPROM by SWING (or SLEEP) button. For example: Infrared control—in heating mode, press “ON/OFF” button to switch on the unit. Take the 24 degree set temperature as the base point, press SWING (SLEEP) within 5 seconds, it will sound 2 times, the unit will enter the heating temperature compensation mode, at this time, if you set the temperature to 25 degree and switch off, the temperature compensation will be +1 degree; if you set the temperature to 26 degree and switch off, the temperature compensation will be +2 degree, and so on, the max. compensation can be +6 degree ( 30 degree); if you want to cancel the compensation, adjust the temperature back to 24 degree. Infrared control—in cooling mode, press “ON/OFF” button to switch on the unit. Take the 24 degree set temperature as the base point, press SWING (SLEEP) within 5 seconds, the unit will enter the cooling temperature compensation mode, at this time, if you set the temperature to 23 degree and switch off, the temperature compensation will be -1 degree; if you set the temperature to 22 degree and switch off, the temperature compensation will be -2 degree, and so on, the max. compensation can be -8 degree ( 16 degree); if you want to cancel the compensation, adjust the temperature back to 24 degree. Read the temperature compensation value: Infrared control type—change to cooling mode, the set temperature is 30 degree, in high speed. Press SWING (SLEEP) 7 times within 5 seconds, the running LED will flash as the current temp. compensation value. Infrared control type—change to heating mode, the set temperature is 16 degree, in high speed. Press SWING (SLEEP) 7 times within 5 seconds, the running LED will flash as the current temp. compensation value. 8.4 Unit debugging: 1. Confirm indoor unit quantity After the unit is electrified, you can check the indoor unit quantity by the outdoor dip switch or the testing board. The display quantity must be in accordance with the actual quantity. If not, please check if there is repeated unit No. or if the dip switch is broken, and if the communication wire is connected correctly. 2. Confirm indoor EEV FAQ: 2.1 The EEV communication wire is not in accordance with the indoor unit. If all the indoors are running, the operation will be normal; when the only one indoor unit is running and it can not cool, while the EEV of the unit not running opens. 2.2 The live wire and the neutral wire of the EEV power cable is not in accordance with those of indoor unit power cable, E7 failure occurs. 2.3 The coil temperature sensor is not in original place or not fixed well, which cause EEV not work properly. The efficiency will be bad or outdoor unit will be liquid return. -76- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Only No.1 unit in cooling If the refrigerant of the unit not running not flow—if yes If No.1 unit in cooling Switch on all the indoor units in turn If No. 1 unit in cooling—if yes, OK If not Short connect the corresponding terminal, open the EEV compulsorily. If it can open, check if the EEV communication wire is in accordance with that of indoor unit and modify. If the refrigerant flows, check if the EEV communication wire is in accordance with that of indoor unit and modify. If yes Can’t open Check if EEV is installed properly, tap the EEV body, or reset. Still not Replace EEV PCB Still not Replace EEV -77- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 3. Confirm cooling operation start Once outdoor stops, the unit Set the unit in cooling mode and begin to run must run again 2 minutes and a half later. If indoor unit blows cold air Confirm compressor state Confirm the louver direction If air circulation is OK Make all indoor units running If temp. drop between air outlet/indlet is normal If the operation voltage is OK Check power voltage and power (230Vf10ˁ˅ circuit. If the running current is 15% of the nominal value (at max. frequency) Check indoor/outdoor temp. Check piping length and refrigerant charge. Check If working pressure is normal noise normal -78- compressor running frequency and if there is abnormal Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 4. Confirm heating operation start Set the unit in heating mode and begin to run Once outdoor stops, the unit can work only 2 minutes and a half later If blowing warm air? Confirm compressor state If air circulation is OK Confirm the louver direction Make all indoor unit running If temp. drop between air outlet/indlet is normal If the operation voltage is OK Check power voltage and power ˄230Vˇ10ˁ˅ circuit. If the running current is 15% of the nominal value (at max. frequency) Check indoor/outdoor temp. Check piping length and refrigerant charge. Check If working pressure is normal frequency compressor and abnormal noise normal -79- if running there is Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 8.5 PCB information AU242FHBIA PCB circuit diagram: 1 2 3 CN21 CN9 CN6 CN22 CN23 жÔØ CN35 CN10 4 Ñõ°É CN8 CN7 ÅçÉä 5 6 7 8 CN4 ËÄͨ ¼ÓÈÈ´ø ·ç»ú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d 10K $9&& 7;B287 $95 &6 $966 6. ,30 ', R11 100 +5V '&567 LOWV 309B$ R12 C43 30 104 31 CX1 10MHz 1 14 2 13 C23 104 IC9 PST600D 100K C19 103 3 P44 P04 P45 P03 P46 P02 P47 P01 VSS P00 8 9 7 6 5 TEST 21 VDD HPRE_SW C44 104 RA1 RA-4(10KX4) GND 5 34 LPRE_SW 45 CJ1 LED4 R99 TX_OUT 10K GND1 RED 2 43 3 GND 33 8 C23 104 GND R31 10K 30 ZD6 5.6V CD4 CD6 100UF 100UF 10K CN13 $ 10 % 10K IC10 CD5 CD7 100UF100UF DQ4 ZD3 9013 5.6V R65 9 R68 10K 31 ZD5 5.6V CD2 1UF R69 4.7K PST600D C ZD4 5.6V GND 29SERIAL 28 +5V 1 27 GND +5V C26 104 8 2 7 3 6 CN27 XP-9A R63 R45 10K 10K 26 +5V 4 GND 5 24C02IC6 R47 10K 22SDA +5V +5V 8 7 IC7 93C46 4 6 B C27 104 5 309B& R67 +5V 40 R66 10K CN3 T1 T28051 10K 39 GND 38 +5V 37 02' 309B' 02' 3(1*6( ;,1 3)&B287 +12V C30 104 ;287 3)&B,1 *1' 1& PFC_OUT 33 PFC_IN CD18 GND VD8 4148 AC1_INR48 4148 1 2 3 4 IC13 CD10 100UF R565.6K ICE2A165 CD11 100UF VD17 FR102 VD20 HER204 +12V R15 180K 27 CT_IN CD13 C15 100UF 103 IC4 ULN2003 R55 5.6K FR102 VD21 R8 C29 104 R36 CD1 5 6 VD16 R545.6K VD11 VD1 1K CD9 100UF FR102 FR102 FR106 +5V 7 CD8 100UF VD12 R71 10 C48 220UF 104 CN2 R53 5.6K VD15 CD3 10UF 34 VD14 FR102 R2 C2 47K/2W 472 18V 7805 35 32 R3 560K/1W ZD2 IC11 7805 36 8 9 7 9013 44 GND 8 CN19 DQ3 J6 J5 J4 J3 46 10 7 11 R70 4.7K R64 +5V 11 6 6 +5V 32 1K C21103 12 TMP86FH46N 12 IC8 4011 351007B P22 P21 13 5 GND R1010K R32 25COM_LED 560 P20 LED2 RED 24 R46 _RST 10K 23 SCL XIN GND 4 C20103 309B% 1&B*1' ,17 28 GND P05 14 4 41 HIV 7;B,1 V-IN R6210K P43 XOUT 42 567 VD7 4148 P06 20 '2 29 R35 VD6 1K 4148 C18103 P07 P42 19 47 Ts 27 DQ1 8550 P41 3 104 48 Ta 23 R18 P15 55 51 104 22 26 P40 15 49 21 25 TX_IN P14 54 50 24 +5V 18 CX2 16.0MHz GND AVSS +12V 2 GND +5V Te 1 2 3 4 5 CD24 4.7UF B C46 17 57 52 Pd(NOP) 20 +5V 16 4051S3 GND 58 56 53 IC1 MB89P857 $&B,1 7F 19 15 4051S2 &23+($7 $&B&203 AC1_IN CN14 14 4051S1 59 P13 6 LED3 RED 13 595RCK AVDD GND 37FR1007 361007A 7 GND R30 GND 12 595SCK CD17 16V/100UF LOW 7 CA1 C28 104 GND 3&7 3:0B; 1000PF*8 62 61 60 3:0B< 6 +5V 11 595SI P12 5 SERIAL R29330 10 +5V GND 63 P11 VREF C11 MM1007 16 R85100 38FR857 8 CN5 R28330 64 9 P37 TX_IN R96 100K ,6 1& '5$,1 R26330 R27330 104 GND 1 2 3 4 5 GND C 2 SW06 1 UP CD14 16V/100UF 8 P10 R95 2K +5V IC3 C47 101 1 TX_OUT R84100 39TO857 C10104 SW04 R94 2K % E B B 2 2 $ % ' ' 1 1 , , ' ' GND R25330 GND C49 3 R24330 6 7 SW07 4 CN1 IC5 ULN2803 P36 GND SW05 R93 2K START 40JP1 $ B 2 ' & 1 4 +5V R50 R51 R88 10K 10K 10K P30 42 41 D B 2 ' & 1 9013 C36 104 C22 103 9013 C25 104 P31 9 ' 1 * +5V P32 P34 P35 JP2 CN34 DQ6 C24 103 CN16 P33 104 C12104 R14100K 1 & , 9 3 H,C GND DQ5 2 SS/TEST STOP 1 , & 1 HPRE_SW R98 1K R13100K R92 2K & 1 2 ' LPRE_SW R97 1K R39 1K +5V IC2 1 HEAT R81 100K GND R38 1K CN26 GND CN24 COOL 2K +5V +5V GND C13 CN25 62)7 *1' )% 9&& 1 CT2 472 472 803 CT_IN 560 1K 103 R83 R72 1K 10K R91 10K +5V C5 FDG_1 561 CD15 100UF 1 1 2 2 ZEN2 C1 C42 VD9 R82 4148 3K AC2_IN +5V +5V CP250 CN12 R73 PFC_IN R75 9 CT1 803 CN30 GND C8 103 C7 103 C9 103 2 5 4 3 R19 100 CN11 R74 10K C45 104 PTC1 C3 0.47UF R5 100 3 T38003 GND CN31 0.47UF 2.2UF L1 4 ZEN1 561 CP250 R37 1K R6 2 SGND R7 2 HER204 IC12 ZD1 R1 11V 471 R76 CD12 5.6K 1000UF TLP421 GND 16 15 14 13 12 9 11 GND GND CD20 100UFVD22 SV2 CD16 16V/100UF 10 SGND +12V A A FR102 CN32 CN15 Title Size Number Revision A2 1 2 3 4 5 -80- 6 7 Date: 3-Sep-2005 File: C:\Documents and Settings\dupeng\ Drawn \ᴼᑇথ䖛ᴹⱘ݇Ѣ80ⱘ Ḡ䴶By: Sheet of 8 Commercial Air Conditioner AU482FHBIA PCB circuit diagram: -81- Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA AU48NFIBJA PCB circuit diagram: 1 2 3 4 5 6 8 7 +5V +5V R304 100¦¸ 100¦¸ R306 TXD1 C326 22uF RXD1 IC303D 109 11 P3.2 R305 IC303E 74HC14 +5V R329 4.7k RESET 8 R332 R334 10k¦¸ IC303F 13 12 4.7k 4148 74HC14 +5V R331 10k¦¸ D311 14 R328 100k¦¸ C330 D313 4148 D312 4148 471 7 +5V R301 R302 R303 6 - 1N4148 D301 D302 D303 4.7k 4.7k 4.7k +5V +5V SK CN302 TXD RXD1 GND2 3 4 ÏÔʾ¹¤×° 5 +5V 74HC14 Z301 QP301 PNP_3906 R333 1k¦¸ 3V CN105 100¦¸ XH5-5»Æ D304 D305 D306 C302 C303 C304 471 471 471 D +5V R308 4.7k RXD0 +5V P0.0 P0.7 104 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 Z303 Z305 NPN_2222A QN302 IC309 9 NPN_2222A 10 11 12 +5V R311100k¦¸ C311204 C312204 13 14 R312 15 100k¦¸ 16 d_outb D_INA D_OUTB D_INB D_OUTANC 8 7 5 Vcc GND 4 IN2 Vin IN1 NC 3 +12V 2 1 54 55 56 57 58 59 60 61 62 P2.1 63 64 65 P2.2 66 P2.3 67 P2.7 68 69 70 P2.4 71 P2.5 72 73 74 P0.5 P0.4 P0.3 P0.2 P0.1 P0.0 P2.4 6 d_outa NC NC D_OUT P2.3 +5V P2.2 R326 2.7k¦¸ R327 MM1007 P2.1 2.7k¦¸ XH2-2½ðÉ« 5 R313 R314 10k¦¸/1% XH2-2ÂÌ C320 P0.7 +5V 104 C313 472 6 7 8 DO GND ORGDI DC SK VCCCS 4 P2.7 P3.0 P3.1 32 P3.2 31 P3.3 30 P3.4 29 P3.5 28 P3.6 27 P3.7 26 25 24 23 22 21 20 19 18 17 16 +5V 15 14 13 12 R315 P0.5 C314 472 C321 C322 30pF 30pF P3.1 C329 105 XH2-2°× R317 R318 10k¦¸/1% 270¦¸ P0.4 4148 2 1 D318 4148 2 74HC14 7 IC304F 12 13 IC306B 6 CN315 +5V Ts 1 2 XH2-2ºÚ 270¦¸ 74HC14 IC304D 8 R321 R322 10k¦¸/1% 270¦¸ 74HC14 IC305C P0.3 5 C316 472 +5V P0.2 R323 R324 47k¦¸/1% 270¦¸ P0.1 C318 472 +12V 1 +5V 2 +5VA3 GND 4 GNDA 5 LED301 LED_GREEN C331 104 74HC14 +5V C301 47uF 13 R325 470¦¸ XH5-5°× IC305F 12 74HC14 7 XH2-2À¶ 8 1 2 3 4 5 6 7 8 9 IC307 OUT 1 IN 1 OUT 2 IN 2 OUT 3 IN 3 OUT 4 IN 4 OUT 5 IN 5 OUT 6 IN 6 OUT 7 IN 7 OUT 8 IN 8 DIODE CLAMP GND C332 ULN2803A 18 17 16 15 14 13 12 11 10 CN310 +12V 1 +12V 2 A 3 B 4 C 5 D 6 XH6-6½ðÉ« +12V μç×ÓÅòÕÍ·§PMV CN305 1 2 3 4 5 6 7 8 9 IC308 OUT 1 IN 1 OUT 2 IN 2 OUT 3 IN 3 OUT 4 IN 4 OUT 5 IN 5 OUT 6 IN 6 OUT 7 IN 7 OUT 8 IN 8 DIODE CLAMP GND C333 ULN2803A 18 17 16 15 14 13 12 11 10 +12V 1 2 3 4 5 6 7 8 9 10 11 12 13 ALM P0.6 XH13-13°×É« CN203 74HC14 IC305A 74HC14 IC304C Title 6 5 74HC14 Size A2 Date: File: 3 4 5 -82- A 2 1 2 GND W_P HEAT SV1 SV2 4_WAY Ox_P F_M_R F_L F_H GND OU Vs 104 10 A 1 B 104 IC305E 11 CN309 SPRY 1 Vo 2 GND 3 +12V 4 XH4-4°× 74HC14 IC305D 9 +12V C334 104 4 +5V +12V +5V+5VA CN301 CN316 +5V Td 1 2 6 3 CN202 R349 10k¦¸/1% 10k¦¸/1% 74HC14 IC305B C317 472 XH2-2°× 5 R348 +12V CN308 +12V 1 FAN1 C335 2 104 XH2-2°× CN307 +12V 1 FAN2 2 R347 IC304E 10 11 +12V 3 LM324 74HC14 C315 472 R319 R320 10k¦¸/1% IC306A 2 10k¦¸/1% R346 +12V 10k¦¸/1% +5V 74HC14 C324 104 LM324 1 R345 IC304B 4 3 14 XH2-2»Æ LED302 D317 9 CN314 +5V Ta 1 2 R352 330¦¸ P3.7 4 74HC14 IC303A +5V RA302 +5V RAA09103 C323 471 JP301 JUMPER LED_RED IC303B ALM CN313 +5V Te 1 2 C PNP_3906 R344 2.7k¦¸ IC304A RAA09103 QP302 R350 4.7k R343 P3.3 2.2k¦¸ 4148 6 1 B30116MHz R351 10k¦¸ R342 1k¦¸/1% D316 R339 74HC14 +5V 2 P3.4 1 +5V 10 IC303C 3 R341 8.2k¦¸/1% 9 LM324 270¦¸ C328 472 5 RA303 3 P2.5 P0.0 12 LM324 IC306C 8 OP XH2-2dz»Æ 13 7 R316 10k¦¸/1% 270¦¸ P3.0 P3.1 P3.2 P3.3 P3.4 P3.5 P3.6 P3.7 D315 4148 R3378.2k¦¸ RAA09103 RA301 14 4148 1 2 R340 1k¦¸/1% 74HC14 93C66 CN312 +5V Tt 1 2 B 270¦¸ IC302 NC P3.0/AD00 P3.1/AD01 P3.2/AD02 P3.3/AD03 P3.4/AD04 P3.5/AD05 P3.6/AD06 P3.7/AD07 NC NC P4.0/AD08 P4.1/AD09 P4.2/AD10 P4.3/AD11 P4.4/AD12 NC P4.5/AD13 Vcc P4.6/AD14 P4.7/AD15 75 76 77 78 79 80 81 82 83 84 1 2 3 4 5 6 7 8 9 10 11 +5V +5VCN311 Tsink 1 2 p0.6/a6/t1clk/pm.2 ANGND Vref P0.5/A5/PM.1 P0.4/A4/PM.0 P0.3/A3 P0.2/A2 P0.1/A1 P0.0/A0 NC P2.0/EPA0/PVER P2.1/SCLK0/BCLK0/PALE NC NC P2.2/EPA1/PROG P2.3/COMP3 P2.7/SCLK1/BCLK1 NC NC P2.4 P2.5 +5V IC306D 14 Z304 N87C196MH Z302 NPN_2222A IC301 4 - Z_5.6V QN301 DACN304 DB 1 2 HBS XH2-2ºì R338 p0.7/a7/t1dir/pm.3 p1.0/txd0 p1.1/rxd0 NC NC P1.2/TXD1 P1.3/RXD1 P6.0/WG1 P6.1/WG1 P6.2/WG2 Vss P6.3/WG2 P6.4/WG3 P6.5/WG3 Vcc NC Vss EA NC NMI RESET C308 100uF QN303 10k¦¸ 100uF P2.6/COMP2/CPVER P6.7/PWM1 P6.6/PWM0 NC NC NC XTAL2 XTAL1 Vss EXTINT P5.4 P5.6/READY P5.1/INST Vss P5.0/ALE Vpp P5.3/RD P5.5/BHE NC P5.2 P5.7 C310 100uF D314 RESET OH CN318 P3.5 R336 10k¦¸ TXD1 RXD1 GUN GUP GVN GVP GWN GWP C319 C307 +5V 104 ALM TXD0 RXD0 100uF 1 2 XH2-2ÒøÉ« +5V +5VA C309 CN317 P3.6 C325 1 2 C306 471 11 100¦¸ D310 C305 471 XH9-9°× TXD0 100¦¸ D309 C 103 P3.4 P3.2 P3.0 R309 R310 R335220¦¸ C327 4 10k¦¸/1% R307 D308 4.7k 4 - 1N4148 D307 R330 4.7k +5V +5V SK CN303 TXD1 RXD2 GND3 4 5 485ͨѶ XH5-5À¶ D CN306 TRIP GUP GVP GWP GUN GVN GWN ALM GND GUP 1 GVP 2 GWP 3 GUN 4 GVN 5 GWN 6 ALM 7 8 9 6 7 º£¶ûKR-160W/(BP)S¿ØÖÆ Number A00000013Revision V1.0 11-Aug-2004 Sheet of C:\Documents and Settings\shibin\×ÀÃæ\KR-160~2.DDB Drawn By: 8 Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 8.6 Dip switch and the ports on PCB functions AU242FHBIA ports on PCB: Ports Ports name Wiring method CN1 IPM-OUT CN2 IPM-POWER CN3 +310V ,GND CN4 Fan motor port To fan motor CN5 SERIAL 857 detecting serial port CN6 Four-way valve port To four-way valve CN7 Live line of electric heater To live line CN8 Neutral line of electric heater To neutral line CN9 Live line of power source To live line CN10 Neutral line of power source To neutral line CN11 Live line of power source To live line CN12 Earthing line To earthing line CN13 Communication port To communication line CN14 Sensor port Including defrosting, discharging, ambient, air return, evaporating temp. sensors CN15 EEV port To EEV CN16 High pressure switch port To high pressure switch CN19 SERIAL 846 detecting serial port, no used CN22 Spray valve port To spray valve CN23 Oxygen generator port IPM output control line To 4-way 15V power source To 310V DC power source To oxygen generator (optional) CN27 Indicator board To exterior testing device, showing failure code CN30 Compressor current detecting To compressor current detecting board CN32 +15VˈGND ———— CN34 Low pressure switch port To compressor low pressure switch CN35 Unloading port To unloading valve -83- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA AU48NFIBJA PCB ports name and functions Ports Ports name Wiring method R, S, T Power supply ports To power of 3 PH, 380V, 50Hz U, V, W Compressor ports To motor (pay attention to phase sequence) E Grounded port Grounding (less than 10Ȧ;more thanȻ1.6mm) N Neutral wire port If 3 phase, it is connected to neutral wire; if 1 phase, it is blank. L1, L2 Reactance port To wire of reactance (non-polar) CN102 Current transducer port To current transducer CN211, CN212 Fan motor port To fan motor CN205 Water pump port To water pump (be spare) CN206 Electric heater port To electric heater CN207 Solenoid valve port To solenoid valve CN208 Solenoid valve port To solenoid valve CN209 Four-way valve port To four-way valve CN210 Oxygen generator port To oxygen generator (blank temporarily) CN303 Testing board port To testing board. Used to modify, check data for after sale personnel. CN304 Communication port To C1, C2 of communication block CN307, CN308 Fan motor port for dispersing heat To fan motor for dispersing heat (be spare) CN310 EEV port To outdoor electronic expansion valve CN311 Radiator temp. sensor port To radiator temp. sensor (blank temporarily) CN312 Mid-condenser port To mid-condenser temp. sensor CN313 Defrosting temp. sensor port To defrosting temp. sensor CN314 Ambient temp. sensor port To ambient temp. sensor CN315 Suction temp. sensor port To compressor suction temp. sensor CN316 Discharging temp. sensor port To discharging temp. sensor CN317 Low pressure switch port To low pressure switch CN318 High pressure switch port To high pressure switch temp. sensor -84- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Below we will comment for the functions of some ports and some changes of PCB 0010451530 and 0010451531: 1. Control Board 0010451530 Herein, the control board we are concerned is the board without CPU. Functions for every port are as follows: CN301: port for power supply, connected with CN202 of the power board. CN302: connected to testing board. CN303: connected to the computer serial port through the testing device. CN304: HBUS communication port. CN305: the driving port for relay, connected to CN203 of the power board. CN306: the driving port for IPM, connected to CN105 of the power board. CN307, CN308: port for the heat-emitting fan. No used at present. CN309: port for the main relay and for testing current, connected to CN104 of the power board. CN310: the driving port for electronic expansion valve. CN311: testing port for the radiator temperature. No used at present. CN312: testing port for the coil temperature Tt. CN313: testing port for the defrosting temperature Te. CN314: testing port for the outdoor ambient temperature Ta. CN315: testing port for the suction temperature Ts. CN316: testing port for the discharging temperature Td. CN317: port for the signal of compressor overheat protection initially,but now for low pressure switch. CN318: port for the signal of high/low pressure protection,but now only for high pressure switch. Control board 1 Control board 2 Control board 3 Totally there are 3 types of control board, because they have different appearance, you will distinguish them much easier. Control board 1 is the earliest edition, because this board is rather big and it will cover the fixing screw which supports the electric control box, also taken into consideration the convenient installation and service, we modified and designed the Control board 2. Control board 2 is the second edition, because there are electric parts on both sides of this board, and -85- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA hard to be installed, we designed the Control board 3. Contro l boa rd 3: the current edition. Now the part number of control PCB is 0010451971 instead of 0010451530. The new control board(0010451971) also can be used as 0010451530,but the connector "OH" must be shorted. 2. Pow er board 0010451531 There are two types of power board, and they have the same dimensions, but have the different voltage testing parts. That is easy to distinguish. The newly power board adopts the voltage sensor to test the voltage. On the board there is a black square type voltage sensor. The old board adopted the LM331 to test the voltage, which is an inserted part IC with 8 feet. However both the new or old power boards can match any of the control board, but the CPU diagrams are different. 3. Fil ter board 0010451536 Originally, the electric control box has not any filter board. In order to avoid the exterior interference and result in the bad communication, the second edition (current edition) are all added the filter board. -86- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 8.7 Testing board for AU48NFIBJA: Press button “mode”, the display will change over in the following sequence: State Frequency Current output Voltage on DC side Ambient temp Discharging temp Suction temp Defrosting temp Coil temp Indoor unit quantity Open degree of EEV Display Fxx.xx A xx.x U xxx 1 xx 2 xx 3 xx 4 xx 5 xx 6 xx 7 xxx 5XQ 6WRS 'HIU &RRO +HDW 5XQ &RRO +HDW 3URJ 6WRS 0RGH (QWHU Note: Please connect the wire on power off. Insert the testing board on the CN302 of the outdoor PCB. The part number is 0010451601. In addition, we set a testing port CN303 which can be connected to the computer through another testing device (part number: 0010451800). The distributor can get the testing device and the testing software from us. Testing procedure: 1. After the unit powered off, connect the wire of testing board to CN302 port, and then pull down the communication wire between outdoor and indoor unit. 2. Check if the wiring is right. If yes, power on the outdoor unit. 3. On the operation panel of the testing board, the relative data can be modified. 4. Press “Prog.”, enter data editing mode. 5. Set data “Pr-00” as “0”ˈthen data can be edited. Press “Enter” to confirm. 6. The other data can be set according to the requirement like this way. 7. After all the data be modified, set “Pr-00” as “1”. 8. Press “Prog.”, quit out of data editing mode. 9. Note: Data of the chip is very important, the improper modification will cause the main parts damaged such as compressor. So before modification, please contact with us. 10. After quitting from data editing mode, operation board will display “P r.E” which will to reset flash. After 3 minutes, it will display “b.P.160”. At this time, pressing the the program. 11. After reset, power off the outdoor. For 1~2 minutes, the outdoor release all the electricity, plug the communication wire between outdoor and indoor to the original position, the modification is over. -87- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 8.8 AU482FIBHA: function specification of SW01, SW02, SW04, SW05, SW06, SW07 Table 1 SW01 SW02 Display of 7 segments LED (LD1,LD2,LD3) 0 0 FFF shows capability overloading (if capability overloading function is chose) Outdoor diagnosis code when without diagnosis code, display: - 1 Outdoor running mode cooling: C heating: H defrosting: J 2 Defrosting area set: display 1------shows that L is set at “12” display 2------shows that L is set at “10” display 3------shows that L is set at “8” When the following condition is available, the unit enters into defrosting running: (TE: defrosting temp., TA: ambient temp.) TEİChTAˉ¢ Note˖C˖TA˘0ćˈC=0.8 TAı0ćˈC=0.6 The value of ¢ can be set according to the selection of jump wiring: selection of jump wiring L M H 12e 10e 8e ¢(ć) 4 INV command frequency˄decimalism˅ e.g.120 stands for 120HZ 5 INV receiving frequency˄decimalism˅ e.g. 84 stands for 84HZ 6 Quantity of indoor units connected˄decimalism˅ e.g. 6 stands for 6 indoor units 7 Back up running: TS sensor: 1 , TE sensor: 1 This function is preset and not available. 8 9 13 14 15 1 0 1 2 3 4 5 6 7 8 9 10 Back up running: TA sensor: 1 , mid-section temp. sensor: 1 This function is preset and not available. Back up running: PD sensor: 1 , PS sensor: 1 This function is preset and not available. Display compensation of capacity class: 4------class 4, 6-----class 6 After the start-up of system is over, the frequency of compressor has gotten the target frequency confirmed by the request of indoor unit capacity for 5 minutes, and then the unit will modulate the capacity. (Note: class 4 and class 6 can be selected. Class 4 is that the capacity class whose range is from 4 classes higher to 3 classes lower than the target frequency. Class 6 is that the capacity class whose range is from 6 classes higher to 4 classes lower than the target frequency. For the unit without pressure sensors, there is no this function.) Display “U” shows that indefinite capacity is chose Display “d” shows that definite capacity is chose (indoor total capacity can’t be over 130%˅ Display o1-----stands for HP Display o2-----stands for HP Display H1-----shows that can be connected with central communication TD sensor data˄decimalism˅ TA sensor data˄decimalism˅ TS sensor data˄decimalism˅ TE sensor data˄decimalism˅ Mid-section of coil pipe sensor data (decimalism) Pd sensor data˄display corresponding saturation temperature˅ Ps sensor data˄display corresponding saturation temperature˅ Opening degree of outdoor PMV1˄decimalism˅ Opening degree of outdoor PMV2˄decialism˅ 2-way valve switched on: SV ON˖ 1ˈno switched on: -Outdoor running current (decimalism) -88- Commercial Air Conditioner 2 3 11 12 13 14 0 1 2 3 4 5 6 7 8 9 10 11 0—7 8 4 5 0—15 0—15 6 7 8 0—15 0—15 0—15 9 10 11 12 13 1—16 1—16 1—16 1—16 1—16 Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Outdoor fan mode :_1˄low speed˅,_2˄med speed˅,_3˄high speed˅ Temperature sensor ON display ON˖ 1ˈOFF˖-Four-way valve switched on: ON˖ 1 Four-way valve not switched on: OFF˖_ _ Running mode selection cooling˖ C, heating: H Dispatch line check cooling˖CC --this function is preset Dispatch line check heating˖HH--this function is preset Cool trial run˖ C --this function is preset Heat trial run: H --this function is preset Swing trial run: _F--this function is preset Indoor unit uniform start/stop˖run: 11/stop: 00˄display -- after 3 minutes˅ --this function is preset Clean abnormal function: CL--this function is preset Outdoor PMV1fully openǃclose function: fully open: FF, fully close: 00 Outdoor PMV2 fully openǃclose function: fully open: FF, fully close: 00 Indoor PMV fully openǃclose function˖fully open: FF Outdoor rated setting: -F Indoor communication state: receiving normal˖ 1 receiving abnormal: Display quantity of communicating indoor unit, e.g. : 6 shows that 6 indoor units are working. Indoor diagnosis code, no diagnosis code: --this function is preset Indoor HP new code:0 stands for 0.8HP, 1 stands for 1HP, 2 stands for 1.2HP, 3 stands for 1.5HP, 4 stands for 2HP, 5 stands for 2.5HP, 6 stands for 3HP, 7 stands for 4HP Old code: 1 stands for 1HP,7 stands for 7HP Indoor required capacity (decimalism) indoor P-CODE Indoor PMV opening degree (decimalism) Indoor saturation temperature (decimalism) -26.0—67.0˄account according to outdoor suction pressure PS˅ Indoor sensor TA temperature˄decimalism˅-26.0—67.0 Indoor sensor TC2 temperature˄indoor gas pipe˅˄decimalism˅-26.0—100.0 Indoor sensor TC1 temperature˄indoor liquid pipe˅˄decimalism˅-26.0—100.0 Single cool trial run--this function is preset Single heat trial run--this function is preset Combination control with outdoor switches Table 2 function summary Cool trial run Indoor trial run in cooling mode, the function is the same as trial run with remote controller, the indoor unit which trials run fixes the temp. difference as max. temp., and send it to outdoor, the other control is similar with normal. Heat trial run Indoor trial run in heating mode, the function is the same as trial run with remote controller, the indoor unit which trials run fixes the temp. difference as max. Method of set, cancel [set] SW01“2”, SW02“03”, press SW04 for more than 2 seconds, after set of trial run success, LD will always display –C until the function is cancelled. [cancel] in trial run state, SW01“02”, SW02“03”, press SW05 [set] SW01“2”, SW02“04”, press SW04 for more than 4 seconds, after set of trial run success, LD will always display –H until the function is cancelled. [cancel] in trial run state, SW01“02”, SW02“03”, press -89- Commercial Air Conditioner Swing trial run temperature, and send it to outdoor, the other control is similar with normal. Indoor trial run in swing mode,the control is the same as swing trial run with remote controller. Uniform running Indoor is uniform running The indoor running mode is corresponding with the setting or memory of remote controller. Uniform stop Indoor uniform stops Indoor PMV fully open compelled Indoor PMV fully compelled in 2 minutes Rated running Set the unit rated running Outdoor PMV1 fully open, closed function Outdoor PMV1 compelled fully open or close in 2 minutes open Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA SW05 [set] SW01“02”, SW02“05”, press SW04 for more than 2 seconds, after set of trial run success, LD will always display –F until the function is cancelled. [cancel] in trial run state, SW01“02”, SW02“05”, press SW05 [set] SW01“02”, SW02“05”, press SW04 for more than 2 seconds, after set of trial run success, LD will display FF for 5 seconds. [cancel] cancel according to operation of remote controller [set] SW01“02”, SW02“06”, press SW05 for 2 seconds, after set success, LD will display FF for 5 seconds. [cancel] cancel according to operation of remote controller [set] SW01“2”, SW02“10”, press SW04 for more than 2 seconds [confirmation] in 2 minutes, 7-segment LED of base board I/F will display “FF” all the time [cancel] the control software will recover PMV to normal open degree after 2 minutes ˄ after indoor software receives the signal of fully open from outdoor, PMV will fully open only in 2 minutes.˅ [set] SW01“02”, SW02“11”, press SW05 for more than 2 seconds, after setting success, LD will display –F, shows that the unit may enter rated running mode, afterwards you can set SW06, SW07.SW06 is used for increasing frequency, while SW07 is used for decreasing frequency. [cancel] cancel according to operation of remote controller [set] SW01“3”, SW02“9”, press SW04 for more than 2 seconds [confirmation] in 2 minutes, 7-segment LED of base board I/F will display “FF” all the time [cancel] the control software will recover PMV to normal open degree after 2 minutes ˄ after indoor software receives the signal of fully open from outdoor, PMV will fully open only in 2 minutes.˅ -90- Commercial Air Conditioner Outdoor PMV2 fully open, closed function Outdoor PMV2 compelled fully open or close in 2 minutes Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA [set] SW01“3”, SW02“10”, press SW04 for more than 2 seconds [confirmation] in 2 minutes, 7-segment LED of base board I/F will display “FF” all the time [cancel] the control software will recover PMV to normal open degree after 2 minutes ˄ after indoor software receives the signal of fully open from outdoor, PMV will fully open only in 2 minutes.˅ 2. Specification for SW03 The two switches of SW03 should be ON or OFF at the same time. -91- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 8.9 Sensor characteristic model AU482FIBIA AU48NFIBJA AB092FCBIA AB142FCBIA AB182FCBIA AE072FCBKA AE092FCBKA AE122FCBKA AE142FCBKA AE182FCBKA AE242FCBKA AS072FCBHA AS092FCBHA AS122FCBHA AS142FCBHA AS182FCBHA AF092FCBHA AF122FCBHA sensor number sensor name sub-sensor number 0010450192 outdoor ambient temp. sensor 001A3800082 0010450193 suction temp. sensor 001A3800093 0010450194 defrosting temp. sensor 001A3800093 0010450195 mid-condenser temp. sensor 001A3800093 0010450196 compressor discharging temp. sensor 001A3800096 0010450194 defrosting temp. sensor 001A3800093 0010451328 pipe temp. sensor 001A3800093 0010451511 discharging temp. sensor 001A3800096 0010451513 suction temp. sensor 001A3800093 0010451514 ambiet temp. sensor 001A3800082 0010450699 pipe temp. sensor 001A3900004 0010451327 ambiet temp. sensor 001A3900003 0010450699 pipe temp. sensor 001A3900004 R25=10Kȍ±3% B25/50=3700K±3% 001A3800103 liquid pipe temp. sensor 001A3900004 R25=10Kȍ±3% B25/50=3700K±3% coil temp. sensor 001A3900003 001A3900004 1.R25=10Kȍ±3% B25/50=3700K±3% 2.R25=23Kȍ±2.5% B25/50=4200K±3% 001A3900059 -92- characteristic R25=10Kȍ±3% B25/50=3700K±3% R25=10Kȍ±3% B25/50=3700K±3% R25=10Kȍ±3% B25/50=3700K±3% R25=10Kȍ±3% B25/50=3700K±3% R80=50Kȍ±3% B25/80=4450K±3% R25=10Kȍ±3% B25/50=3700K±3% R25=10Kȍ±3% B25/50=3700K±4% R80=50Kȍ±3% B25/80=4450K±3% R25=10Kȍ±3% B25/50=3700K±4% R25=10Kȍ±3% B25/50=3700K±3% R25=10Kȍ±3% B25/50=3700K±3% R25=23Kȍ±2.5% B25/50=4200K±3% Commercial Air Conditioner R80=50Kȍ±3% B25/80=4450K±3% T(ć) -30 -29 -28 -27 -26 -25 -24 -23 -22 -21 -20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Rnom(Kȍ) 11600 10860 10170 9529 8932 8375 7856 7372 6920 6498 6104 5736 5392 5071 4770 4488 4225 3978 3747 3531 3328 3138 2960 2793 2636 2489 2351 2221 2099 1984 1877 1775 1680 1590 1506 1426 1351 1280 1214 1151 1092 1036 983.2 933.4 886.4 841.9 800 760.8 722.8 687.3 653.8 622 592 553.6 R80=50Kȍ±3% B25/80=4450K±3% T(ć) 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA R25=10Kȍ±3% B25/50=3700K±3% Rnom(Kȍ) T(ć) Rnom(Kȍ) 536.6 511.1 486.9 464 442.3 421.7 402.1 383.6 366 349.3 333.5 318.4 304.1 290.5 277.6 265.3 253.6 242.5 232 221.9 212.3 203.2 194.5 186.3 178.4 170.9 163.7 155.9 150.4 144.2 138.3 132.7 127.3 122.1 117.2 112.5 108 103.8 99.68 -20ć -19 -18 -17 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 90.79 85.72 80.96 76.51 72.33 68.41 64.73 61.27 58.02 54.97 52.1 49.4 46.86 44.46 42.21 40.08 38.08 36.19 34.41 32.73 31.14 29.64 28.22 26.4 25.61 24.41 23.27 22.2 21.18 20.21 19.3 18.43 17.61 16.83 16.09 15.38 14.71 14.08 13.48 12.9 12.36 11.84 11.34 10.87 10.43 10 9.59 9.21 8.84 8.48 8.15 7.83 7.52 7.23 -93- R25=10Kȍ±3% B25/50=3700K±3% T(ć) 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 Rnom(Kȍ) 6.95 6.68 5.43 5.6 5.59 5.73 5.52 5.32 5.12 4.93 4.9 4.58 4.42 4.26 4.11 3.97 3.83 3.7 3.57 3.45 3.33 3.22 3.11 3.11 2.9 2.81 2.72 2.63 2.54 2.49 2.38 2.3 2.23 2.16 2.09 2.03 1.96 1.9 1.85 1.79 1.73 1.68 1.63 1.58 1.54 1.49 1.45 Commercial Air Conditioner R25=23Kȍ±2.5% B25/50=4200K±3% R25=23Kȍ±2.5% B25/50=4200K±3% T(ć) Rnom(Kȍ) T(ć) Rnom(Kȍ) -20ć 281.34 24ć 24.12 -19ć 263.56 25ć 23 -18ć 247.04 26ć 21.94 -17ć 231.66 27ć 20.94 -16ć 217.35 28ć 19.99 -15ć 204.02 29ć 19.09 -14ć 191.61 30ć 18.23 -13ć 180.04 31ć 17.42 -12ć 169.24 32ć 16.65 -11ć 159.17 33ć 15.92 -10ć 149.77 34ć 15.22 -9ć 140.99 35ć 14.56 -8ć 132.78 36ć 13.93 -7ć 125.11 37ć 13.34 -6ć 117.93 38ć 12.77 -5ć 111.22 39ć 12.23 -4ć 104.93 40ć 11.71 -3ć 99.04 41ć 11.22 -2ć 93.52 42ć 10.76 -1ć 88.35 43ć 10.31 0ć 83.5 44ć 9.89 1ć 78.94 45ć 9.49 2ć 74.67 46ć 9.1 3ć 70.65 47ć 8.74 4ć 66.88 48ć 8.39 5ć 63.33 49ć 8.05 6ć 60 50ć 7.73 7ć 56.86 51ć 7.43 8ć 53.91 52ć 7.14 9ć 51.13 53ć 6.86 10ć 48.51 54ć 6.6 11ć 46.04 55ć 6.34 12ć 43.72 56ć 6.1 13ć 41.52 57ć 5.87 14ć 39.45 58ć 5.65 15ć 37.5 59ć 5.44 16ć 35.66 60ć 5.24 17ć 33.92 18ć 32.27 19ć 30.72 20ć 29.25 21ć 27.86 22ć 26.54 23ć 25.3 -94- Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 9. Wiring diagram AU242FHBIA Wiring diagram: OUTDOOR UNIT WIRING DIAGRAM Compressor Spray Valve 4-Way Valve Crankcase Fan Motor Heater M Oxygen Generator CN3 CN7 CN8 CN22 CN6 CN4 N CN101 L1 B Y/G Control Board CN2 Y/G CN12 Connected To Indoor Communication Wire CN21 COM NO U B Power Supply 1PH,220v-230V~,50Hz CN11 IPM R CN13 RL1 CN1 CN102 W R 1PH,220v-230V~,50Hz OR BL Indoor unit Power Supply R V W Y/G W CN10 PTC P CN9 CN23 F3.15A/250V CT Parts in dashed frame are optional. M Fan Motor Capacitor BL B Defrost Temp. Sensor Discharge Temp. Sensor Ambient Temp. Sensor Suction Temp. Sensor Mid-Condensor Temp.Sensor W CN14 Y CN16 CN30 CN15 CN34 R Electrolytic Capacitor 2500F/400V ˇ ˉ ˇ ˉ Electrolytic Capacitor 100F/400V M High-pressure Switch B B Low-pressure Switch Electronic expansion Valve B:Black BL:Blue BR:Brown R:Red W:White Y:Yellow OR:Orange Y/G:Yellow/Green Reactor Rectifier 25A/600V Rectifier 50A/600V B AU482FIBIA Wiring diagram: Capacitor High Voltage Control Board Te Ta Td 6: 6: 6: Fuse Fan Capacitor R R AC Motor A 6SUD\ 9DOYH W B Earthing Y/G W W Electrolytic Capacitor W Y/G W B B W 1 / & & Fan Capacitor AC Motor B To indoor uint R 4-Way Unloading Crankcase Oxygen valve Valve Generator Heater CT B W B B /RZ3UHVVXUH 6ZLWFK +LJK3UHVVXUH 6ZLWFK 'HIURVW 7HPS 6HQVRU &RPSUHVVRU 9HQW 6HQVRU $PELHQW 7HPSHUDWXUH 6HQVRU &RPSUHVVRU ,QKDOH 6HQVRU 3LSH 7HPSHUDWXUH 6HQVRU 0 EEV CN2 L CN1 N /' /' /' Ts Current Detecor 6: 6: Tc B W R Power Supply B AC Contactor R R Resistance -95- B Rectifier Reactor Electrolytic Capacitor 1.Parts in dashed frame are optional 2.B:Black R:Red W:White Y/G:Yellow/Green Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA AU48NFIBJA wiring diagram: 4-WAY OX-P SV2 CRANKCASE HEART SV1 FM3 FM4 0010577105 W-P CN210 3 2 1 CN210 3 2 1 RY206 CN208 CN207 CN206 CN205 3 2 1 3 2 1 3 2 1 3 2 1 RY205 RY204 RY203 RY202 RY201 CN202 Fan capacitor CF1 5 4 3 2 1 FAN1 RY208 Power Supply Board 5 4 3 2 1 FAN2 SCLD-P-B-4PDT-C 1 2 3 4 5 6 CN203 7 8 9 10 11 12 13 RY207 CN212 1 2 3 4 5 1 CN1 CN3 2 3 1 2 3 CN302 4 5 RY209 CN211 CF2 Fan capacitor 1 2 3 4 5 1 CN303 2 3 CN301 4 5 1 2 3 4 5 T3.15A/250VAC 1 2 CN2 3 4 5 CN204 CN201 2019 16 1512 11 8 7 4 1 3 2 1 1 2 CN308 1 2 CN307 1 2 JP301 CN311 CN312 Control Board CN313 1 2 CN314 1 2 CN315 CN316 1 2 3 4 5 6 7 CN305 8 9 10 11 12 CN306 13 1 2 3 4 5 6 7 8 9 CN309 1 2 3 4 1 2 1 2 1 2 1 2 CN317 1 2 CN318 1 2 CN310 1 2 3 4 5 CN304 TSINK Tt Te Ta Ts Td 0H(L) 0P(H) 1 2 Remarks: L N 1. CN302 ǃ CN303 areports for controllers,and will be used in maintenance. 2. Parts in dashed frame are optional. 1 2 3 4 5 6 7 8 9 CN105 2019 16 1512 11 8 7 4 1 CN103 Symbols meaning symbol part name part name symbol CM compressor Te defrosing temp. sensor FM fan motor Ta ambient temp. sensor OX-P oxygen bar function Ts suction temp. sensor Td discharging temp. sensor 4-WAY 4-way valve SV solenoid valve 0H Low pressure switch 0P High pressure switch HEAT crankcase heater EEV Electronic expansion valve W-P water pump CT current transducer TSINK radiator temp. sensor mid-condenser temp. sensor Tt C101 C102 C103 R101 N U C104 C105 C106 PTC R114 IPM P V L2 W () (+) RY101 RECTIFIER () () () 1 1 2 CN107 2 3 CN104 3 4 Noise Filter Color symbol: symbol B BL R C1 C2 W Y G Communication Y/G Anti-surge relay CT U R V W W R S T N Lm1 Lm2 B Power Supply CM symbol black blue red white yellow green yellow/green Y/G Y/G AB**2FCBIA wiring diagram: Indoor unit wiring diagram M M electronic expansion valve Builtin EEV type 1 2 3 4 5 6 2 3 4 CN6 sw02 1 CN11 CN 2 serial CN16 CN9 Indoor control board sw03 emergency LED1 switch LED2 LED3 10 9 8 7 6 5 4 3 2 1 OPER BEEP1 POW COMP TIM sw01 Remote receiver CN13 CN1 4 3 2 1 d b ac 2 R 1 CN4 CN7 3 2 1 3 2 1 C CN19 R pump motor D CN20 Attentions: The CN9 is not available . So the second bit of SW03 is must be set "ON",And CN19,CN22 is not available. CN16 is a serial communication port for service. negative ion generator or high voltage accumulator outdoor communication W B R <* electronic expansion valve box power supply and communication Wired control type The dip switch setting when out of factory Outside EEV type indoor power B:Black BL:Blue BR:Brown R:Red W:White Y/G:Yellow/Green CN22 Wired controller and remote receiver only can be chosen one of type at will. The setting of SW01,SW02 and SW03 : 1.The former three bits of SW01 are used to set unit number,which are operated by the installer on field . 2.The fourth bit of SW01 is used to choose different indoor fan speed in heating mode."ON"means that fan speed can be set as middle and low level,"OFF"means that fan speed can be set as high,middle and low level. 3.The first bit of SW02 and SW03 is used to choose wired control type or remote control type. "ON"means that the unit with wired controller(other parts are as the same as remote control unit). And "OFF"is remote controller. The unit with wired controller can make remote operation on wired controller with remote controller such as YR-H71 . 4.The second bit of SW02 is used to choose built-in or outside electronic expansion valve setting . "ON"means built-in type : CN6 is connected with electronic expansion valve and indoor unit control refrigerant flow itself. "OFF"means outside type: CN25 is connected with electronic expansion valve communication,and the electronic expansion valve box(MP3A) control indoor refrigerant flow. M Wired controller B CN18 unit code setting CN14 Remote control type A CN25 FUSE T3.15A/250VAC 1 LED4 2 3 4 5 6 7 8 9 10 sw01 In the diagram,gas pipe temp. sensor,liquid pipe temp. sensor,room temp.sensor ,indoor fan motor,float switch, pump motor,swing motor are necessary parts; Wired controller,remote receiver,electronic expansion valve are parts matched with the model(combined usage); negative ion generator or high voltage accumulator are optional parts for health and comfort˄combined usage). CN5 1 1 2 2 3 2 1 float switch Room temp. sensor 4 3 2 1 CN8 1 liquid pipe temp. sensor fan motor 5 2 3 4 5 CN3 0010577029 About the PCB setting swing motor 1 gas pipe temp. sensor M fan capacitor 1PH.220-230V~.50Hz NOTE˖Must connect electronic expansion valve box power and communication from corresponding indoor,wiring sequence must correspond with the label respectively,other wise, will cause PCB of indoor and electronic expansion valve box not work and damaged. -96- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA AE**2FCBKA wiring diagram: 0010573324 Indoor unit wiring diagram M electronic expansion valve NOTE:The dashed " ˉˉˉ "in indoor controll board is PCB inner wiring. for built-in EEV type BL 2 3 4 1 gas pipe temp. sensor CN6 temperate CN9water sensor CN5 1 2 2 3 CN8 CN17 1 1 liquid pipe temp. sensor BL 1 2 3 4 5 6 2 3 2 CN11 1 transformer 1 ambient temp. sensor CN24 CN23 unit code setting CN16 CN15 2 CN25 BR Indoor control board 1 CN13 CN18 W FUSE T3.15A/250VAC RL7 RL6 RL5 RL4 RL3 RL2 CN22 RL1 CN14 1 2 3 4 receive display PCB choice of remote controller type serial 1 2 1 2 3 4 5 6 7 8 9 10 1 CN1 1 SW1 10 9 8 7 6 5 4 3 2 LED3 LED2 LED1 2 2 float switch indoor temp sensor 1 2 CN2 CN1 CN10 2 1 choice of wired controller type R CN4 7 6 5 4 3 2 1 B C CN12 3 2 1 CN19 Y/G M connector M D CN3 CN20 3 2 1 1 2 B fan capacitor A CN7 3 2 1 R R R M earthing pump motor swing motor Attentions: The water temp sensor (CN9) and indoor temp sensor (CN24) are unuseful now. The fourth bit of 4 position dial switch is used to choose the different speed of indoor fan under heating mode. "ON" means that the speed of indoor can be choosed from middle and low."OFF" means that the speed of indoor fan can be choosed from high,middle and low. indoor fan motor negative ion generator or high voltage accumulator resumable heat protector 80ćˈ10A/250VAC wired controller electronic expansion valve box power supply and communication outdoor communication auxiliary heater SW1 FUSE T15A/250VAC indoor power NOTE˖Must connect electronic expansion valve box power and communication from corresponding 1PH.220-230V~.50Hz indoor,wiring sequence must correspond with the label respectively,other wise, will cause PCB of indoor and electronic expansion valve box not work and damaged. About control board outer connector: In the diagram,gas pipe temp. sensor,liquid pipe temp. sensor,indoor fan motor,transformer are necessary parts˗Wired controller,receive display,electronic expansion valve,float switch,pump motor,swing motor are parts matched with the model(combined usage ˅˗ Auxiliary electric heater,negative ion generator,high voltage accumulator are optional parts for health and comfort˄combination usage arbitrarily).Wired controller and receive display only can choose one at will. The unit with remote controller is matched with receive display: 1.Ceiling concealed type:CN11 must be short connected with a jump wire ˗ 2.Duct type ˖connected with float switch and pump motor ˗ 3.Cassette type:connected with float switch ǃ pump motor and swing motor ˗ 4.Cabinet type:CN11 must be short connected with a jump wireˈconnected with swing motor ˗ The unit with wired controller(equipped with wired controllerˈcan make remote operation on wired controller with remote controller such as YR-H39) ˖ Short connect CN15 ǃCN17 together with jump wireˈother parts are the same as remote control unit Setting method with electronic expansion valve outside: CN23 is disconnected,CN25 is connected with electronic expansion valve communication,and the electronic expansion valve box(MP3 or MP2) control indoor refrigerant flow. ˖ valve: Setting method with built-in electronic expansion CN23 is short connected with a jump wire, CN6 is connected with electronic expansion valve ˈand indoor unit control refrigerant flow itself. one-off heat protector 105ćˈ10A/250VAC only applicable for unit with auxiliary electric heater CN23 CN15 CN17 short connector for built-in electronic expansion valve short connector for wired controller CN16 serial communication port CN11 connector for float switch LED3 indicator ˄runningˉred˅ LED2 indicator ˄timer ˉyellow˅ LED1 indicator ˄power ˉgreen˅ RL7 emergency switch(ON/OFF) indoor fan motor low-speed relay RL6 indoor fan motor Mid-speed relay RL5 indoor fan motor High-speed relay RL4 health function module relay RL3 pump motor relay RL2 swing motor relay RL1 auxiliary eletric heater relay B:Black BL:Blue BR:Brown R:Red W:White Y/G:Yellow/Green AS**2FCBHA wiring diagram: 0010573625 VIEW A TRANSFORMER 1 Display Bar M CN2 CN13 CN11 R W CN10 CN1 XB1 3 FAN MOTOR R W B Y/G 2 TO ELECTROMAGNETIC VALVE BOX 4 VIEW A CN12 XB2 SW2 Control Board SW01 CN14 ON CN7 OFF CN8 EMERGENCY SWITCH LIQUID PIPE TEMP. SENSOR ROOM TEMP. SENSOR GAS PIPE TEMP. SENSOR CN5 M CN6 STEPPING MOTOR EARTHING R: RED B: BLACK W: WHITE BL: BLUE BR: BROWN Y/G: YELLOW/GREEN Note: W B 1.SW01 is the dip switch to set N L unit number. 2CN6 is a serial port for some Power Supply device. 1PH,220-230v~,50Hz -97- Y/G Earthing Wire C1 R C2 R Communication Wire Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA MP3A wiring diagram: MP3A wiring diagram 0010577068 FUSE T3.15A/250VAC CN1 CN2 Control board CN3 electronic expansion valve3 M electronic expansion valve2 M CN4 CN7 CN5 CN8 CN9 6 5 4 3 2 1 6 5 4 3 2 1 CN15 CN6 1 CN14 2 SERIAL CN6 CN10 CN11 CN12 CN13 65 43 21 electronic expansion valve1 M B W BR B W BR B W BR L1 N1 C1 L2 N2 C2 L3 N3 C3 Y/G indoor 3 indoor 1 indoor 2 B:Black BR:Brown W:White Y/G:Yellow/ Green NOTE: Power supply and communication wire must be connected with the corresponding indoor units.Wiring sequence must be correspondent respectively,L and N must not be connected reversely,otherwise, it will cause the unit not work and demaged. On running, "indoor 1" must be electrified always, or air conditioner does not work normally.When the system is equipped with MP2A, the installer should use the corresponding two-way electronic expansion valve communication wiring and its driver port . -98- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 10. Failure code and troubleshooting 10.1 Outdoor failure code: AU242FHBIA, AU482FIBIA: check indoor mainboard LED1 or outdoor mainboard LED1. Failure code Failure description 01 Outdoor defrosting temperature sensor TE circuit failure 02 Ambient temperature sensor TA circuit failure 03 Suction temperature sensor TS circuit failure 04 Discharging temperature sensor TD circuit failure 05 Outdoor mid-condenser temperature sensor failure 06 Over current abnormal 07 Current mutual inductor failure 09 IPM protection 10 EEPROM on PCB incorrect 11 Discharging temperature protection action 13 Pressure switch circuit abnormal 14 Pressure switch circuit abnormal 19 Discharging temperature protection action when in low frequency 20 Communication abnormal when chip 857 receives signal from chip 846 21 Compressor over current failure 22 Communication abnormal when chip 846 receives signal from indoor unit 23 Chip 846 EEPROM/chip 857 EEPROM failure -99- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA AU48NFIBJA malfunction code: LED display on Malfunction description Code the regulating board Normal Defrosting temperature sensor abnormal Ambient temperature sensor abnormal Suction temperature sensor abnormal Discharging temperature sensor abnormal Coil temperature sensor abnormal Over current protection 0 Normal 1 E.4. 2 E.1. 3 E.3. 4 E.2. 5 E.5. If sent to indoor unit? Remarks Yes Yes Resumable Yes Resumable Yes Resumable Yes Resumable Yes Resumable O.C. Yes After there are current malfunction for 3 P O.C. no times in 1 hour, the testing board will 6 display the last abnormal reason P X.X. Need powered off and restart Current sensor abnormal Overload protection 8 IPM protection Read 7 9 EEPROM value wrongly 10 C.T. temperature over high abnormal After trouble shooting, need powered off and restart O.L. Yes After there are current malfunction for 3 P O.L. no times in 1 hour, the testing board will E.P. Yes display the last abnormal reason P X.X. P E.P. no Need powered off and restart P E.E. O.D. Discharging Yes no Need reset and restart After there are current malfunction for 3 Yes times in half an hour, the testing board 11 P O.D. will display the last abnormal reason P no X.X. Need powered off and restart High pressure switch abnormal Voltage over low protection Voltage over high protection Compressor overheat protection Recover the parameter set when out of factory Clear the malfunction memory Need reset Radiator temperature sensor abnormal 12 13 14 O.P. L.U. Yes Resumable Yes After there are voltage malfunction for 3 times in 1 hour, the testing board will P L.U. O.U. display the last abnormal reason P X.X. Yes Need powered off and restart P O.U. 15 O.H. 16 P I.A. 17 P C.T. 18 P r.E. -- -- Yes Resumable no Need reset and restart no Need reset and restart no Need reset and restart No use temporarily -100- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 10.2 Indoor failure code A. Wired control type indoor unit: the dip switch of wired controller is 1 and 3 at ON, 2 and 4 at OFF. Failure code Failure description E0 Float switch abnormal E1 Outdoor unit failure E2 Abnormal mode operation E3 Liquid pipe temperature sensor failure E4 Gas pipe temperature sensor failure E5 Repeated indoor unit number (E5 flashes for a while and then turn to E9) E7 Communication abnormal with EEV box E8 Communication abnormal between wired controller and indoor PCB E9 Communication abnormal between indoor and outdoor EB (pre-set, not available) Water temperature sensor abnormal B. Infrared control type indoor unit: TIMER lamp flash times Failure description Once Liquid pipe temperature sensor failure twice Gas pipe temperature sensor failure 3 times Ambient temperature sensor failure 4 times Communication abnormal between indoor and outdoor 5 times Communication abnormal with EEV box 10 times Indoor motor abnormal 11 times Float switch or pump motor abnormal 12 times Repeated indoor unit number 13 times Indoor over heat Note: if indoor RUN lamp flashes, that shows outdoor abnormal, so no matter how many times it flashes, you should check outdoor indicator flash times and the relative failure code. -101- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 10.3 AU242FHBIA, AU482FIBIA troubleshooting: 1.Communication failure between indoor and outdoor units Wired controller: E9; 4 flashes of TIMER lamp Is indoor unit address properly set? Without repetition? no Reset address yes Are communication terminals of indoor and outdoor units securely connected? no Reconnect yes Is shielded wire used for communication? Use shielded wire. Shield layer should be grounded at single point no yes Are communication wire and power cable set separately? no wiring Separately yes Is there external signal interference? yes Eliminate interference no Is indoor mainboard poorly welded? yes Replace indoor PCB no Are communication resistance and capacitor of indoor PCB correct? See NOTE no yes Check outdoor mainboard 0010450351. Make necessary replacement -102- Replace indoor PCB Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 2. Sensor failure no Is sensor properly connected? reconnect yes Are resistance and temperature characteristics of sensor normal? no change sensor yes check if PCB is defective, if yes,replace 3.EEPROM failure: outdoor displays 10 start no Is EEPROM in mainboard inversely connected or in poor contact? re-set replace PCB 4. Over current protection: 6 flashes of outdoor ALARM lamp, fault readout: 6 Is supply voltage good? Is wire specification correct? no Modify power supply circuit yes Are connectors in good condition? no Check and reconnect yes no Check if the compressor current is over protection value: 30A Is filter board in good condition? yes Change PCB no yes 1. Is output voltage among U, V and W balanced? 2. Disconnect all terminals. Is resistance between P and N; P and U, V, W; N and U, V, W acceptable? Change filter board no Check: 1. Is a valve in system close? 2. Is piping clogged; 3. Is system overfed; is there air in system; 4. (Cooling cycle) Is condenser dirty? Does outdoor fan motor run at low speed or stop? 5. (Heating cycle) Is evaporator or filter dirty? Does indoor fan motor run at low speed or stop? 6. Is ambient temperature too high? Is system overloaded? yes Is pressure acceptable? no yes no Is compressor in good condition? yes Is compressor winding resistance acceptable? Is it stuck? no Is rectifier in good condition? Replace power module 1. Check diode characteristics of rectifier+, AC; - AC 2. Measure voltage between P and N, which should be 310VDC at 220VAC yes Is electrolytic capacitor for filtration in good condition? no Check capacitance and conductivity and make necessary replacement yes Check mainboard and make necessary replacement -103- Commercial Air Conditioner 5. IPM power module protection 9 flashes of outdoor ALARM light, fault readout:9 Possible causes: 1. Short-circuit or overcurrent 2.Four-way control supply (15VDC) is less than 13.5V. 3.Module is hot with a temperature higher than 145° C. Are connectors in low voltage PCB in poor contact? yes Check and reconnect yes Is 10-pin connector between IPM and mainboard short-circuit or in poor contact? yes Replace cable no Measure + and - terminals of electrolytic capacitor. Is output voltage of rectifier acceptable (310VDC at 220V.) no Replace rectifiter yes Check point: CN12 in mainboard. Is four-way supply voltage less than 13.5V (normal value: 13.5-16.5VDC) yes Replace power board no if the compressor is normal no Is compressor winding resistance acceptable? Is it stuck? yes Is power module too hot? yes Is silica gel well distributed on radiation fins? no Is current up to protection yes limit of power module? 1.Is voltage of supply circuit too low? 2.Is heat exchanger or indoor fan motor broken? 3.Is ambient temperature too high? Is system overloaded? no 1.Is output voltage among U, V and W balanced? 2.Disconnect all terminals. Is resistance between P and N; P and U, V, W; N and U, V, W acceptable? no Replace power module yes Check mainboard and make necessary replacement -104- Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 6. Discharging temperature protection 11 flashes of outdoor ALARM light; fault readout: 11 When is temperature protection activated: Temperature of discharge line is above 115° C. no Are stop valves in gas pipe and liquid pipe of outdoor unit open totally? Open the stop valve yes Does EEV work properly during heating cycle? Check 1) Connector 2) Winding resistance 3) Valve 4) Mainboard yes no Is actual discharging temperature detected by thermometer too high? no Repair outdoor EEV Is discharging temperature sensor in good condition? yes yes Does indoor fan work properly during heating cycle? Does outdoor fan work properly during cooling cycle? replace PCB no Check fan motor and capacitor yes yes Is filter or heat exchanger dirty? cleaning no Measure balance pressure and running pressure to see if the refrigerant is too much or lack. Is there air in system? Is there a leak? yes Conduct leak test. Evacuate and recharge no Is piping twisted or deformed? Is piping clogged with weld? no yes Adjustment or replacement no When TD is high, is refrigerant injection circuit in good condition? Is injection capillary in good condition? no 1.Check coil and valve body of electromagnetic valve. 2.Check injection capillary. -105- Replace TD sensor Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 7. High pressure overhigh protection: 13 flashes of outdoor alarm lamp. When high pressure switch is activated: Pressure is above 3.0 MPa. Are connectors of CN16 pressure switch in good condition? no Check and reconnect yes Is high pressure switch activated? no replace PCB yes Is pressure value detected by pressure gage above 3MPa? no Replace high side pressure switch yes Are stop valves in suction pipe and liquid pipe of outdoor unit open? no Open stop valve yes yes Is piping twisted or deformed? no if outdoor fan motor work properly during cooling cycle? and if indoor fan motor and indoor EEV work properly during heating cycle? Repair or replacement no Check fan motor or indoor EEV yes yes Is filter or heat exchanger dirty? cleaning no Is system overfed? Is there air in system? Is reading of discharging pipe pressure gauge oscillatory? yes Evacuate and recharge -106- Commercial Air Conditioner 8. Low pressure too low protection Low pressure is lower than 0.05MPa for 3 minutes; or lower than 0.05MPa for 30 seconds during halt time no Are connectors of pressure switch in good condition? Check and reconnect yes no Is low side pressure switch activated? Replace PCB yes Is pressure valve detected by pressure gauge lower than 0.05MPa? no Replace low pressure switch yes If outdoor stop valves of gas pipe and liquid pipe are open totally no Open stop valve yes Is piping twisted or deformed? no Adjust and maintain no Do outdoor fan and PMV work properly during cooling cycle? Do indoor fan and EEV work properly during heating cycle? no Repair fan motor and EEV yes If the filter and heat exchanger are dirty yes Cleaning yes If refrigerant circuit is leak? or lack of refrigerant? yes Check leakage point, evacuate and recharge -107- Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 9. Fault in built-in overload protection of compressor Normally closed; open in the event of a fault. Fault readout: 8; 8 flashes of ALARM light no Is CN14 in power supply drive properly connected? reconnect yes Check power power source board to see if the 10th pin of CN13 has low level. If not, replace it. no Is overload protector open-circuit? yes no Is resistance of compressor winding acceptable? Replace compressor yes If compressor current and discharge pressure are acceptable, the problem is not related to refrigeration system. Check if piping is clogged, ambient temperature is high or heat exchanger is soiled 10. Current transducer failure Display 7, ALARM lamp flashes 7 times check if the wiring is correct according to wiring diagram no reconnect yes if compressor is running? Is rectifier in good condition? Is AC contactor activated? Is contact good? Is power module in good condition? no yes Is compressor current acceptable? Is DC voltage between both ends of CN4 acceptable? yes Check connection of mainboard CN4 and make necessary replacement no Is connection between filter board CN1 and mainboard CN4 normal? yes Replace filter -108- no reconnect Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 10.4 AU48NFIBJA troubleshooting: 1.Communication failure Note: For outdoor units before December 2004, in the event of 3 IPM or high current faults, outdoor unit will stop signal transmission to indoor unit. Indoor unit will display communication fault. Normally, testing board will indicate number of indoor units. The number is fixed. Wired controller display: E9; 4 flashes of indoor TIMER light of models with remote control Is number of indoor units indicated by testing board correct? Changeable? yes yes Is indoor unit address properly set? Without repetition? Communication normal no Reset address yes Are communication terminals of indoor and outdoor units securely connected? no Reconnect yes Is shielded wire used for communication? Use shielded wire. Shield layer should be grounded at single point no yes Are communication wire and power cable set separately? no wiring Separately yes Is there external signal interference? yes Eliminate interference no Is indoor mainboard poorly welded? yes Replace indoor PCB no Are communication resistance and capacitor of indoor PCB correct? See NOTE no Replace indoor PCB yes Check outdoor mainboard. Make necessary replacement NOTE: 1. R49.R50 resistor in AS072-182FCBHA circuit and R40.R41 resistor in AE072-242FCBKA circuit have a resistance of 100 K instead of 47K AS models and C28~C30 of AE models use 104 polyester resistors. -109- Commercial Air Conditioner 2.Sensor failure Are connectors of sensor properly connected? no Reconnect yes Are resistance and temperature characteristics of sensor acceptable? no Replace sensor yes Check PCB and replace 3.EEPROM failure no Is CPU chip installed firmly? Reinstall in right direction yes Is fault corrected after JP301 is reset? yes Normal no yes If chip is broken? Replace chip no Is it normal after replacing chip? no Check PCB and replace -110- Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 4. Over current protection: outdoor LED302 flashes 6 times Is supply voltage good? Lack of phase? no Modify power supply circuit yes Are connectors in good condition? no Check and reconnect yes Is actual compressor current detected by ammeter or test board (0010451601) above protection limit 16.9A? no Wrong report. Replace 0010451971 or 0010451530 yes 1. Is output voltage among U, V and W balanced? 2. Disconnect all terminals. Is resistance between P and N; P and U, V, W; N and U, V, W acceptable? no Check: 1. Is a valve in system close? 2. Is piping clogged; 3. Is system overfed; is there air in system; 4. (Cooling cycle) Is condenser dirty? Does outdoor fan motor run at low speed or stop? 5. (Heating cycle) Is evaporator or filter dirty? Does indoor fan motor run at low speed or stop? yes Is pressure acceptable? no yes no Is compressor in good condition? yes Is 3-phase rectifier in good condition? no Replace power module Is compressor winding resistance acceptable? Is it stuck? 1.Check if resistance between rectifier+, L1L2L3; and - L1L2L3 complies with diode characteristics. 2. Measure + and - terminals of CN201. Measure voltage between P and N, which should be 530VDC at 380VAC yes Is electrolytic capacitor for filtration in good condition? no Check capacitance and conductivity and make necessary replacement yes Check mainboard and make necessary replacement -111- Commercial Air Conditioner 5. IPM power module protection 9 flashes of outdoor LED302 light. Possible causes: 1. Short-circuit or overcurrent 2. Control supply is less than 13.5V. 3.Module is hot with a temperature higher than 145° C Are connectors in light current board in poor contact? yes Check and reconnect yes Is 9-pin connector between IPM and low voltage board short-circuit or in poor contact? yes Replace cable no Check point: + and - pins of CN201 in power source board. Is output voltage of rectifier acceptable (530VDC at 380V) no Replace rectifiter yes Check point: CN12 in mainboard. Is four-way supply voltage less than 13.5V (normal value: 13.5-16.5VDC) yes Replace power board no if the compressor is normal no Is compressor winding resistance acceptable? Is it stuck? yes Is power module too hot? yes Is silica gel well distributed on radiation fins? no Is current up to protection yes limit of power module? 1.Is voltage of supply circuit too low? 2.Is heat exchanger or indoor fan motor broken? 3.Is ambient temperature too high? Is system overloaded? no 1.Is output voltage among U, V and W balanced? 2.Disconnect all terminals. Is resistance between P and N; P and U, V, W; N and U, V, W acceptable? no Replace power module yes Is there any damaged component in power module driver? no Replace power module driving board yes Check low voltage and make necessary replacement -112- Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 6. Discharging temperature protection 11 flashes of outdoor LED302 When is temperature protection activated: Temperature of discharge line is above 115° C no Are stop valves in gas pipe and liquid pipe of outdoor unit open totally? Open the stop valve yes Does EEV work properly during heating cycle? Check 1) Connector 2) Winding resistance 3) Valve 4) Mainboard no Repair outdoor EEV yes Is actual discharging temperature detected by thermometer too high? no Is discharging temperature sensor in good condition? yes yes Does indoor fan work properly during heating cycle? Does outdoor fan work properly during cooling cycle? replace PCB no Check fan motor and capacitor yes Is filter or heat exchanger dirty? yes cleaning no Measure balance pressure and running pressure to see if the refrigerant is too much or lack. Is there air in system? Is there a leak? yes Conduct leak test. Evacuate and recharge no Is piping twisted or deformed? Is piping clogged with weld? no yes Adjustment or replacement no When TD is high, if SV2 by pass circuit can work normally no Check coil and valve body of electromagnetic valve. -113- Replace TD sensor Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 7. High pressure overhigh protection: 12 flashes of outdoor LED302 When is high pressure switch activated: Pressure is above 3.0 MPa. Are connectors of CN318 pressure switch in good condition? no Check and reconnect yes Is high pressure switch activated? no replace PCB yes Is pressure value detected by pressure gage above 3MPa? no Replace high pressure switch yes Are stop valves in suction pipe and liquid pipe of outdoor unit open? no Open stop valve yes yes Is piping twisted or deformed? no if outdoor fan motor work properly during cooling cycle? and if indoor fan motor and indoor EEV work properly during heating cycle? Repair or replacement no Check fan motor or indoor EEV yes yes Is filter or heat exchanger dirty? cleaning no Is system overfed? Is there air in system? Is reading of discharging pipe pressure gauge oscillatory? yes Evacuate and recharge -114- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 8. Low pressure too low protection Outdoor LED flashes 15 times. Low pressure is lower than 0.05MPa for 3 minutes; or lower than 0.05MPa for 30 seconds during halt time no Are connectors of CN317pressure switch in good condition? Check and reconnect yes no Is low side pressure switch activated? Replace PCB yes Is pressure valve detected by pressure gauge lower than 0.05MPa? no Replace low pressure switch yes If outdoor stop valves of gas pipe and liquid pipe are open totally no Open stop valve yes Is piping twisted or deformed? no Adjust and maintain no Do outdoor fan and PMV work properly during cooling cycle? Do indoor fan and EEV work properly during heating cycle? no Repair fan motor and EEV yes If the filter and heat exchanger are dirty yes Cleaning yes If refrigerant circuit is leak? or lack of refrigerant? yes Check leakage point, evacuate and recharge -115- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 10.5 H-MRV indoor unit troubleshooting: 1. Models with wired controller Models with wireless remote controller Fault code readout: E0 11 flashes of Timer light. Fault description: The float switch or pump motor is broken. Check if the switch and pump connector are in good condition? No Repair Yes Check if the float switch is open? Yes No Replace the indoor PC board Check if the pump is running? Yes Check if the drain system is clogged or the float switch is stuck. No Check if the pump is poweron? Yes Clean the drain system and reconnect the switch. Yes Replace the pump 2. Models with wired controller Models with wireless remote controller Fault code readout: E1 The Operation light flashes. Check in accordance with the list of outdoor fault codes. Fault description: Failure in outdoor unit Faults in models with remote controller can be identified by the number of flashes made by fault indicator of outdoor unit. Check in accordance with the list of fault codes. 3. No. Models with wired controller Models with wireless remote controller 1 Readout: E3 1 flash of Timer light. 2 Readout: E4 2 flashes of Timer light. 3 N/A 3 flashes of Timer light. 1 Description: Liquid line temperature sensor (Ti) is short-circuit or open-circuit. 2 Description: Suction line temperature sensor (T0) is short-circuit or open-circuit. 3 Description: Ambient temperature sensor is short-circuit or open-circuit. -116- Commercial Air Conditioner Check if the sensor is properly connected to the mainboard. Yes No Check the sensor resistance with a multimeter: R25ć=10Kȍ+3%˗ B(25/50)=3741K+70K Reconnect Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Yes Replace the mainboard. No Replace the sensor 4. Models with wired controller Models with wireless remote controller Readout: E5 6 flashes of Timer light. Description: Transmission error between indoor unit 846 chip and 808 chip. What to do: Replace the mainboard. 5. Models with wired controller Models with wireless remote controller Readout: E7 5 flashes of Timer light. Description: Transmission error with electronic expansion valve driver. Check if the electric control of indoor unit and the electric control of expansion valve share the same supply and if live wire and null wire are properly connected. No Reconnect Yes Check if the internal wiring of indoor unit and expansion valve is properly done. For AEFCBKA mainboard, a jumper wire is used to select the function of wire controller. Yes Check if the mainboard is noticeably damaged and if the control panel works properly after replacement. Check if the PCB CN23 of AC series is short connected. No Replace the mainboard Yes Remove the short wire -117- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 6. Models with wired controller Models with wireless remote controller Readout: E8 / Description: Transmission error between wire controller and indoor unit mainboard Check if the wire controller is properly connected to A, B and C of indoor unit. No Reconnect Yes No Check if the voltage between A and B is +12VDC? Replace indoor unit mainboard Note: CN15 and CN17 of AE series should be short connected. Yes Check if the voltage between C and B changes regularly? No Replace the wire controller 7. Models with wired controller Models with wireless remote controller Readout: N/A 10 flashes Description: PG failure in the fan of indoor unit Check if the fan is properly connected to the mainboard. Yes Check if PIN 3 and 1 of CN2 (color models) or CN8 (regular models) are up to DC 5V. No Yes Check if there is pulse output from PIN2 and 1 of CN2 or CN8. Yes Replace the indoor unit mainboard. No Replace the fan. -118- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 8. Models with wired controller Models with wireless remote controller Readout: E9 4 flashes of Timer light Description: Transmission error with outdoor unit (an alarm will be given 4 minutes after the appliance is started.) Check if there is repetition in the indoor unit address IDs. No Check if the transmission line is shortcircuit or open-circuit; if the shield wires at both ends of transmission line are earthed properly; if the earth wire of outdoor unit is properly earthed. No Disconnect the indoor unit transmission lines from the control panel and connect them to the outdoor unit. Check if the number of indoor units is steady through the outdoor unit mainboard or the test kit. No Check if the transmission resistor and capacitor in indoor unit mainboard are in good condition. See flow chart of troubleshooting for outdoor unit. -119- Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Models with wired controller Models with wireless remote controller N/A 8 flashes of Timer light Description: Fault with 12V supply of heavy current board in expansion valve Check if there are noticeable burns or hot components in the mainboard. Use a multimeter to check if the 12V supply in 7805 chip of mainboard is in good condition. Measure the central and the left pins of the chip. Check if the mainboard is properly connected. Replace the mainboard Models with wired controller Models with wireless remote controller N/A 9 flashes of Timer light Description: Fault with polarity of indoor unit (to be determined) Check if the null wire and the live wire of indoor unit are properly connected. Check if the mainboard and the fan wire are noticeably damage. It’s recommended to bring spare parts of fan. Connect the fan to see if there is any alarm. If yes, replace the mainboard. If no, replace the fan. -120- sound pressure level DB sound pressure level DB . 40 0 . 50 0 . 63 0 80 . 80 0 1 . 00 0 1 . 25 0 1 . 60 0 2 . 00 0 2 . 50 0 3 . 15 0 4 . 00 0 5 . 00 0 6 . 30 0 8 . 00 0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 00 250 600 000 500 150 000 000 300 000 000 500 000 000 0 1 1 1 2 2 3 4 5 6 8 10 12 16 20 -121- 0 10 20 25 .0 31 .5 40 .0 50 .0 63 .0 .0 10 0 .0 12 5 .0 16 0 .0 20 0 .0 25 0 .0 31 5 .0 40 0 .0 50 0 .0 63 0 .0 80 0 .0 10 0 0 0. 12 5 0 0. 16 0 0 0. 20 0 0 0. 25 0 0 0. 31 5 0 0. 40 0 0 0. 50 0 0 0. 63 0 0 0. 80 0 0 0. 00 0 0. 50 0 0. 00 0 0. 00 0 0. third octave band frequency Hz 10 12 16 20 fan low cooling low heating low fan med cooling med heating med 40 30 fan high cooling high heating high 50 60 sound level-AB182FCBIA third octave band frequency Hz fan low cooling low heating low fan med 10.0 5 cooling med 20.0 . 31 heating med 30.0 0 fan high 40.0 . 25 cooling high 50.0 0.0 heating high 60.0 70.0 noise level-AU242FHBIA Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 11. Noise level sound pressure level DB sound pressure level DB 60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 75 73 71 69 67 65 63 61 59 57 55 53 51 49 47 45 43 41 39 37 35 33 31 29 27 25 .0 25 .0 25 .5 31 .5 31 .0 40 .0 40 .0 50 .0 50 .0 63 .0 63 -122third octave band frequency Hz .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 80 100 125 160 200 250 315 400 500 630 800 000 250 600 000 500 150 000 000 300 000 000 500 000 000 8 5 6 4 3 2 2 1 1 1 20 12 16 10 noise level-AE242FCBKA third octave band frequency Hz .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 80 100 125 160 200 250 315 400 500 630 800 000 250 600 000 500 150 000 000 300 000 000 500 000 000 8 6 5 3 4 2 2 1 1 1 20 16 10 12 noise level-AU482FIBIA heat (89Hz) cool (89Hz) heat (89Hz) cool (89Hz) Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA sound pressure level DB sound pressure level DB 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 76 74 72 70 68 66 64 62 60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 .0 25 .0 25 .5 31 .5 31 .0 40 .0 40 .0 50 .0 50 .0 63 .0 63 -123third octave band frequency Hz .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 80 100 125 160 200 250 315 400 500 630 800 000 250 600 000 500 150 000 000 300 000 000 500 000 000 8 6 5 4 2 2 3 1 1 1 20 10 12 16 noise level-AE242FCBKA third octave band frequency Hz .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 80 100 125 160 200 250 315 400 500 630 800 000 250 600 000 500 150 000 000 300 000 000 500 000 000 2 6 0 8 6 5 4 3 2 2 0 1 1 1 2 1 1 1 noise level-AU48NFIBJA cool (90Hz) heat (90Hz) cool (90Hz) heat (90Hz) Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA 12. Performance curves heating capacity( kW) ƵAU242FHBIA 11.00 10.00 9.00 8.00 7.00 6.00 5.00 4.00 3.00 2.00 1.00 0.00 -15 -13 -11 -9 -7 -5 -3 -1 1 3 5 7 9 11 13 15 outdoor temp. 10.00 9.00 cooling capacity(kW) 8.00 7.00 6.00 5.00 4.00 3.00 2.00 1.00 0.00 18 23 28 33 outdoor temp. -124- 38 43 17 Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Ƶ AU48** 1) Calculation method Calculation method of refrigerating capacity-Refrigerating capacity to be known = Refrigerating capacity x (1) x (2) x (3) x (4) x (5) W (3) Capacity modification value Capacity compensation value of outdoor air dry-bulb temperature condition 1.2 1.2 1.1 1.1 1.0 1.0 0.9 0.9 -5 0.8 15 20 24 indoor air wet-bulb temperature(*) 0 5 10 15 20 25 under airflow variation rate of indoor unit group (only for airflow type unit) 30 35 40 43 1.0 0.9 80 90 100 110 120 airflow variation rate (5) Capacity compensation suitable for total capability of indoor unit group (cooling) Outdoor unit 120 100 lo ho 30 86 87 88 89 91 90 92 93 94 95 96 100% 99 99 98 97 98 97 ha la hc hb lb A B lc 80 60 40 20 C 10 20 25 30 40 50 60 70 80 90 100 110 120 standard capacity Indoor unit group he capacity modification value 50 40 -30 -40 -50 1.1 outdoor air dry-bulb temperature(*) (4) Fall of refrigerant pipe of indoor and outdoor unit, capacity compensation value of pipe length 20 10 0 -10 -20 Capacity modification value (1) Capacity compensation value of indoor air wet-bulb temperature condition 0 L(m) Length of refrigerant pipe (corresponding length) L (m) 20 40 60 80 100 120 135 Total capacity of indoor unit group 2) Calculation method of heating capacity—Heating capacity to be known = Heating capacity ((1) x (2) x (3) x (4) x (5) x (6)) W (1) Capacity modification under indoor air wet-bulb temperature condition 1.2 1.2 1.1 1.1 (2) Capacity modification under outdoor air wet-bulb temperature condition (3) Capacity modification value under airflow variation rate of indoor unit group 1.1 1.0 1.0 1.0 0.9 0.9 0.8 0.8 15 0.7 20 24 0.9 80 0.5 -15 -10 -5 0 5 outdoor air wet-bulb temperature(*) 10 (4) Fall of refrigerant pipe of indoor and outdoor unit, capacity compensation value of pipe length 50 40 capacity modification value 120 H=ho+(the max. value of ha, hb, hc) L=lo+(the max. value of la, lb, lc) 0 lo 86 87 88 89 91 90 92 93 94 95 96 he hb ha Length of refrigerant pipe (corresponding length) L (m) -126- lb le B C 100 80 60 40 20 standard capacity hc A Indoor unit group 100% 99 99 98 97 98 97 ho 10 20 25 30 40 50 60 70 80 90 100 110 120 15 (5) Capacity compensation suitable for total capability of indoor unit group (heating) Outdoor unit 30 -30 -40 -50 100 110 120 0.6 indoor air dry-bulb temperature(*) 20 10 0 -10 -20 90 20 40 60 80 100 120 135 Total capacity of indoor unit group Commercial Air Conditioner Model: AU242FHBIA, AU482FIBIA, AU48NFIBJA Sincere Forever Haier Group Haier Industrial Park, No.1, Haier Road 266101, Qingdao, China http://www.haier.com