Download TECHNICAL MANUAL MANUAL TÉCNICO
Transcript
10 ACCUMULATION The versions with accumulation offer different set-ups that vary on the basis of the effective pressure that you want to obtain, the characteristics of the pumping unit, and the presence or absence of holes for integrative resistance. The following tables show the main characteristics of the components of the hydraulic circuit, while the graphs on these pages show the relative pressures. The accumulation tanks with holes for heaters are equipped with plastic, temporary closing plugs. Glycole mix Hm bar l (1) l (2) l (3) 30 3.2 2.174 978 510 Water temperature °C 25 2.8 2.646 1190 622 20 2.3 3.118 1404 732 15 1.8 3590 1616 844 Reference condition max. min. 10% 40 -2 0,507 (1) 10% 60 -2 0,686 (2) (3) 10% 85 -2 0,809 20% 40 -6 0,434 (1) 20% 60 -6 0,604 (2) 20% 85 -6 0,729 (3) 35% 40 -6 0,393 (1) 35% 60 -6 0,555 (2) 10.1 35% 85 -6 0,677 (3) The standard value of pre-charge pressure of the two expansion tanks is 1.5 bar, while their volume is 24 litres, maximum value 6 bar. The calibration of the tanks must be regulated on the basis of the maximum difference of level (H) of the user (see figure), according to the formula: p (calibration) [bar] = H [m] / 10.2 + 0.3. For example, if the level difference H is 20m, the calibration value of the tank will be 2.3 bar. If the calibration value obtained from the calculation is lower than 1.5 bar (i.e. for H < 12.25), maintain the standard calibration. GlYjÛºÛ?Û£Û~Û¶Û ?ÛeYpÛ¨~©ÛºÛÛe ?ÛºÛ~Ûe GlYjÛºÛ~ÛZYj 10.1.1 Calibration of expansion tank Reference working conditions: (1) Cooling: Max. water temp. 40 °C. Min water temp 4 °C. (2) Heating (heat pump): Max. water temp 60 °C. Min water temp 4 °C. (3) Heating (boiler): Max. water temp 85 °C. Min water temp 4 °C. ? ?ÛºÛÛe GlYjÛºÛ~ÛZYj MAXIMUM WATER CONTENT in the system ≥ 12.25 1.5 3852 1732 904 Correction factor WARNING Before start-up, the installer must assemble the heaters. If these heaters are not immediately necessary, the plastic plugs must be replaced with suitable metal plugs. The table below indicates the maximum water content, in litres, of the hydraulic system, compatible with the capacity of the expansion tank supplied as standard. The values shown in the table refer to three conditions of maximum and minimum water temperature. If the effective water content of the hydraulic system (including the accumulation tank) is greater than that shown in the operational conditions table, another, additional expansion tank must be installed, measured (using the common criteria) with reference to the additional volume of water. From the following tables, it is possible to obtain the values of maximum system content, also for other operational conditions with glycol water. The values are obtained by multiplying the reference value by the correction coefficient. 24 Hydraulic height Expansion tank calibration Reference value water content Reference value water content Reference value water content ?ÛeafÛ¨© (1) Ensure that the highest terminal unit doesn’t exceed 55 metres of level difference. (2) Ensure that the lowest terminal unit can support the global pressure present at that point.