Download SL AUTO - I.c.f.
Transcript
PAGE 8 PAGE 1 GUIDE DE DEPANNAGE SCHEMA DE PRINCIPE SECHE LINGE CARTE ELECTRONIQUE DE PUISSANCE M/AT SL AUTO CONDENSATION PH BL/VI AP N BL/OR SEC.PORTE REF.2/10454/D TC2 OR CE SECHE LINGE A PROGRAMMATION ELECTRONIQUE EST EQUIPE D'UN PROGRAMME DIAGNOSTIC QUI PERMET DE VOUS AIDER DANS LA RECHERCHE DE PANNE TC4 PRES.COND VIOL BAC PLEIN TC5 IMPORTANT CON.6V TC6 CON.6V CARTE ELECTRONIQUE D'ACCES VIOL BE/CL R2:150° AVANT D'EFFECTUER CE PROGRAMME ASSUREZ-VOUS QUE: J2 MA/NR CON.2V 1200W FUS. -LE TAMBOUR SOIT VIDE DE LINGE -LE FILTRE SOIT PROPRE (PAS DE PELUCHE) ATTENTION NE PAS PASSER SOUS L'EAU VE/F 1000W R1:140° -LE CONDENSEUR DOIT ETRE PROPRE CON.4V BE/F KL1 MAR MOTEUR PANIER ATTENTION CD NOIR VE/CL CE PROGRAMME EST CONSTITUE DE 2 PHASES CON.3V MOTEUR VENTILATEUR . CD PHASE 1 ROUG (PAGES 2/3)-PERMET LE CONTROLE DE LA FONCTIONNALITE DE LA CARTE D'ACCES (CONTROLE DES VOYANTS ET DES TOUCHES) LES ETAPES B-C-D-E SONT INDEPENDANTES LES UNES DES AUTRES ELLES PEUVENT ETRE REALISEES DANS UN ORDRE INDIFFERENT L'ETAPE F PERMET DE VERIFIER SI TOUTES LES ETAPES ONT ETE REALISEES CLAPET CAPTEUR HYGROCAPT ROUG ART POSITIONNE GR PHASE 2 CON.2V GR J6 CON.4V CON.4V CAPTEUR HYGROCAPT (PAGE 4/5)-PERMET LE CONTROLE DE LA FONCTIONNALITE DES COMPOSANTS: MINIRUPTEUR DE PORTE CAPTEUR HYGROCAPT MOTEUR SENS + ET CHAUFFAGE 1/2 PUISSANCE MOTOVENTILATEUR CHAUFFAGE PLEINE PUISSANCE ET MOTEUR SENS COMMANDE CLAPET CAPTEUR HYGROCAPT ARRET POSITIONNE PAGE 2 LEGENDE PHASE 1 VOYANT ALLUME CONTROLE CARTE D'ACCES PAGE 3 PHASE 1 VOYANT ETEINT VOYANT CLIGNOTANT INDIQUE LES VOYANTS A VERIFIER CONTROLE MANUEL DES BOUTONS ET DES VOYANTS ENTREE EN AUTOTEST NOTA:LE VOYANT L12 S'ALLUME DES L'APPUI DU MARCHE/ARRET ACTIONS MANUELLES FONCTIONS/SECHE LINGE VISUALISATION CARTE DIAGNOSTIC CHENILLARD -APPUI SUR MARCHE-ARRET. APPUI SIMULTANNE SUR: CHENILLARD TOUCHE. A SI CHENILLARD DES 4 VOYANTS INDIQUES = OK 1 2 3 FOIS SUR TOUCHE. CLIGNOTEMENT EN CHENILLARD L6-L5-L7-L1 VOUS ETES RENTRE DANS SI DEFAUT,VERIFIER: LE PROGRAMME CONTROLE -L'ALIMENTATION(TENSION SECTEUR) -MARCHE/ARRET 3 (en - de 5s) LE TAMBOUR TOURNE EN SENS + SIGNAL SONORE (3 BIPS) -LIAISON CARTE PUIS./CARTE D'ACCES SI NON CHANGER CARTE D'ACCES 2 3 1 SI CHENILLARD DES 5 VOYANTS INDIQUES = OK ALLUMAGE EN CHENILLARD TOURNER(1/2TOUR)LE BOUTON ENCODEUR sens + B 4 DES VOYANTS L11-L8-L10-L9-L12 (LE TAMBOUR TOURNE EN SENS +) DANS LE SENS + HORAIRE CHENILLARD SI NON CHANGER CARTE D'ACCES CHENILLARD 4 SI CHENILLARD DES 3 VOYANTS INDIQUES ET CHENILLARD ET SI ALLUMAGE FIXE DES 2 VOYANTS INDIQUES=OK ALLUMAGE EN CHENILLARD CHENILLARD TOURNER(1/2TOUR)LE BOUTON ENCODEUR sens - C 4 SI NON CHANGER CARTE D'ACCES DES VOYANTS L15-L14-L13 (LE TAMBOUR TOURNE EN SENS +) DANS LE SENS - ANTI-HORAIRE ALLUMAGE FIXE DES VOYANTS L17-L18 4 SI CHENILLARD DES 3 VOYANTS INDIQUES ET CHENILLARD CHENILLARD ET SI ALLUMAGE FIXE DU VOYANT INDIQUE=OK SI NON CHANGER CARTE D'ACCES D APPUYER SUR TOUCHE. CLIGNOTEMENT EN CHENILLARD L6-L5-L7 2 L1 (LE TAMBOUR TOURNE EN SENS +) ALLUMAGE FIXE DU VOYANT L1 2 SI CHENILLARD DES 3 VOYANTS INDIQUES=OK CHENILLARD CHENILLARD E APPUYER SUR TOUCHE. SI NON CHANGER CARTE D'ACCES L2 ALLUMAGE EN CHENILLARD DES VOYANTS L3 L4 5 (LE TAMBOUR TOURNE EN SENS +) 5 APPUYER 1 FOIS SUR TOUCHE CHENILLARD FIXE OU CLIGNOTANT 3 CLIGNOTEMENT EN CHENILLARD DES VOYANTS L6-L5-L7 (LES PHASES B-C-D-E ONT ETE TOUTES REALISEES) F ALLUMAGE FIXE VOYANT L1 CHENILLARD (LE TAMBOUR TOURNE EN SENS +) OU OU L6 (SI VOUS VOULEZ SHUNTER LES PHASES B-C-D-E) 3 APPUYER 3 FOIS EN - DE 2S SUR . L5 CLIGNOTEMENT EN CHENILLARD DES VOYANTS L6-L5-L7 3 CLIGNOTEMENT VOYANT L1 L7 L1 PAGES 4-5 PHASE 2 ACTIONS MANUELLES A FONCTIONS VISUALISATION CARTE EXTINCTION DES VOYANTS G A ARRET DU MOTEUR SENS + DIAGNOSTIC MINIRUPTEUR SEC.PORTE OUVRIR LE COUVERCLE B SI ALLUMAGE FIXE DES VOYANTS INDIQUES=CAPTEUR OK SI CLIGNOTEMENT DES VOYANTS INDIQUES VERIFIER: B FERMER LE COUVERCLE CONTROLE CAPTEUR HYGROCAPT ALLUMAGE FIXE VOYANT L18-L19 -LIAISON 4V/4V CAPTEUR /CARTE PUIS. SI LIAISON=OK H CHANGER CAPTEUR HYGROCAPT SI DEFAUT CAPTEUR PHASE H -->ARRET MOTEUR ET CHAUFFAGE L11 I APPUYER SUR 3 ALLUMAGE FIXE VOYANT L11 CONTROLE MOTEUR SENS + CONTROLE PUISSANCE 1200W 3 SI DEFAUT CAPTEUR PHASE H -->ARRET VENTILATEUR L8 J APPUYER SUR 3 ALLUMAGE FIXE VOYANTS L8 CONTROLE VENTILATEUR 3 SI DEFAUT MOTEUR VERIFIER: -LIAISON MOTEUR /CARTE PUIS. -CONDENSATEUR -MOTEUR SI DEFAUT PUIS.1200W VERIFIER: -LIAISON ELEM.CHAUFFANT/CARTE PUIS. -THERMOSTATS 1/2 POUCES -ELEMENT CHAUFFANT (FUS.THERM) SI NON CHANGER CARTE DE PUISSANCE ->BLOCAGE DU PROG.DIAGNOSTIC AVEC L11 ALLUME SI CAPTEUR DEFECTUEUX EN PHASE H SI DEFAUT VENTILATEUR VERIFIER: -LIAISON VENTILATEUR /CARTE PUIS. -CONDENSATEUR - MOTEUR VENTILATEUR SI NON CHANGER CARTE DE PUISSANCE SI DEFAUT BOBINE CAPTEUR -->ARRET MOTEUR ET CHAUFFAGE L18 L10 K ->BLOCAGE DU PROG.DIAGNOSTIC AVEC L11 ALLUME SI CAPTEUR DEFECTUEUX EN PHASE H APPUYER SUR 3 CONTROLE BOBINE CLAPET CAPTEUR ALLUMAGE FIXE VOYANTS L18 ET L10 CONTROLE MOTEUR SENS - 3 CONTROLE CHAUFFAGE MAXI ALLUMAGE FIXE VOYANT L12 SI DEFAUT CAPTEUR PHASE K -->ARRET MOTEUR SI VOYANTS INDIQUES FIXE =BOBINE OK SI CLIGNOTEMENT VOYANT L18 : BLOCAGE DU PROG.DIAGNOSTIC VERIFIER: -LIAISON BOBINE/CARTE DE PUIS. SI NON CHANGER CAPTEUR HYGROCAPT SI DEFAUT CHAUFFAGE VERIFIER: -LIAISON ELEM.CHAUFFANT/CARTE PUIS. -THERMOSTATS 1/2 POUCES -ELEMENT CHAUFFANT (FUS.THERM) SI NON CHANGER CARTE DE PUISSANCE ->BLOCAGE DU PROG.DIAGNOSTIC AVEC L17 ALLUME SI CAPTEUR DEFECTUEUX EN PHASE K L17 L12 L ALLUMAGE FIXE L17 SI PAS D'ARRET POSIT.(nota) APPUYER SUR 3 ALLUMAGE FIXE VOYANT L17 A L'ARRET PANIER (NOTA:POUR LES SL NON EQUIPES DE L'OPTION 3 CONTROLE PHASE D'ARRET POSITIONNE (ARRET PANIER EN POSITION HAUTE) CLIGNOTEMENT VOYANT L17 PDT LA PHASE D'ARRET PANIER . LE VOYANT L17 CLIGNOT APRES 10S) M EXTINCTION DE TOUS LES VOYANTS APPUYER SUR 1 1 MARCHE/ARRET SORTIE DU PROGRAMME CONTROLE SI DEFAUT ARRET POSITIONNE VERIFIER: -LIAISON ARRT POSIT/CARTE PUIS. -PRESENCE AIMANT -CAPTEUR ARRET POSITIONNE SI NON CHANGER CARTE DE PUISSANCE PAGE 6 PAGE 7 16 17 GR J7 J8 VCC HR GND CMT2 CMT1 COM NC LED3 LED1 LED2 J2 SCL SDA MUX NC NEUTR J1 OPT2 OPT1 COM J3 J4 CARTE D'ACCES START MA/AT COM CARTE DE PUISSANCE CTN J6 GR DOSSERET SECT SCHEMA DE CABLAGE BL/VI BL/VI SAV 57X1511 SL AUTO CD VE/CL ROUG ROUG MAR NOIR BE/F BE/CL VIOL VIOL OR BL/OR BL/VI SEC.PORTE VE/F MA/NR J14 GR J6 GR SCL SDA N PH ARRET POSITIONNE VE/CL ROUG ROUG MAR NOIR BE/F BE/CL VIOL VIOL OR BL/OR BL/VI VE/F N BA . PHASE TERRE MAS.PLAQ. NEUTRE BLANC BLANC BLANC BLANC ROUGE ROUGE VE/CL MARRON BE/F NOIR VIOL VIOL BE/CL JAUNE 1200W ELEMENT CHAUFFANT SOCLE CAPTEUR HYGROCAPT BLANC BLANC BLANC BLANC ROUGE ROUGE MARRON VE/CL NOIR BLEU MAR NOIR BLEU COND.8UF COND.1.5UF BE/F MARRON NOIR VENTILATEUR 1000W BAC PLEIN FUS. MOTEUR PANIER ROUGE BA NOIR MARRON 0R NOIR VIOL VIOL JAUNE R2 R1 PRESENCE COND. BE/CL VE/F. (230V-50HZ) THERMOSTAT 3 5 6 7 8 9 1 2 3 COMMANDE ELEMENT CHAUFFANT 1200W 5 6 7 8 9 10 11 12 13 14 15 10 COMMUN MOTEUR PANIER 11 COMMANDE MOTEUR PANIER SENS + 12 COMMANDE MOTEUR PANIER SENS - 13 COMMANDE BOBINE CLAPET NEUTRE+SECURITE PORTE SECURITE PORTE 14 COMMANDE BOBINE CLAPET SECURITE BAC PLEIN+PRESENCE CONDENSEUR 15 COMMANDE MOTEUR VENTILATEUR 16 CAPTEUR ARRET POSITIONNE 17 CAPTEUR ARRET POSITIONNE COMMANDE ELEMENT CHAUFFANT 1000W PHASE N L VE/F FILTRE AP BL/OR L THERMOSTAT 2 1 MA/NR BL/OR ORANGE MA/NR CARTE DE PUISSANCE SECURITE BAC PLEIN+PRESENCE CONDENSEUR COMMUN ELEMENT CHAUFFANT (1000+1200W) ATTENTION LORS DU REMPLACEMENT DE LA CARTE DE PUISSANCE: -RESPECTER LA CONCORDANCE ENTRE LA COULEUR DES FILS DU TORON ET LES MARQUAGES INSCRITS SUR LA CARTE -TIRER SUR LES CONNECTEURS POUR LES DESENFICHER (NE PAS TIRER PAR LES FILS) MARQUAGE/CARTE COULEUR FIL MA/NR -MARRON/NOIR VE/F -VERT FONCE BL/VI -BLANC/VIOLET BL/OR -BLANC ORANGE OR -ORANGE VIOL -VIOLET BE/CL -BLEU CLAIR BE/F -BLEU FONCE NOIR -NOIR MAR -MARRON ROUGE -ROUGE VE/CL -VERT CLAIR