Installation Manual
Version 4.6
GB
F
I
E
DK
Installation Manual
Manuel d’installation
Manuale installatore
Manual de la instalación
Installationsmanual
PROTECT™ 2200i · PROTECT™ 1100i · PROTECT™ 600i
Copyright 2012, PROTECT A/S – Denmark
2
PROTECT™ 600i/1100i/2200i
GB Table of contents
STANDARD O
AN
F
E
C
OP
INDEPENDENTLY
TESTED AND GAINED
EN 50131-8
EUROPEAN STANDARD
ES
IC
EU
R
Tables des matières
OPÉENNE
EUR
PO
E
M
LES CANONS
À
UR
CONFORME
Á LA NORME
EN 50131-8
NORME EUROPÈENNE
N
SIO
NO
R
1. Important – si vous installez pour la première fois un générateur de fumée
Lisez s’il vous plait le manuel d’installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Démontage du capot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Montage du support de fixation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Emplacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Instructions de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Câblage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2. Connections, réglages et tests
Carte à circuit imprimé . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dipswitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Entrées . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Volume de fumée . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Branchement de la batterie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installer le réservoir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Essai . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3. Remise
Information et enregistrement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Recommandations de Service et de Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4. En cas de défauts
Rechercher les défauts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Fusibles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Indicateurs d’état/codes erreur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5. Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
ANTI-INT
MÉE
RU
FU
Indice
Vignet_I_tryk.pdf
RI
PE
1
SISTEMI DI S
IC
U
QUESTO PRODOTTO
È CONFER ME CON
EN 50131-8
STANDARD EUROPEO
NEBBIOG
EN
ZZA
A
RE
1. Importante – per chi installa un generatore di nebbia per la prima volta
Consultazione del manuale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Apertura del contenitore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Montaggio delle staffe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Posizionamento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Sicurezza . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cablaggio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2. Collegamenti, impostazioni e test
Circuito stampato . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installazioni tipiche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dipswitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Ingressi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Volume della nebbia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Collegamento delle batterie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installazione del contenitore del liquido . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3. Consegna dell’impianto
Informazione e registrazione . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Contratto di manutenzione . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4. In caso di funzionamento anomalo
Identificazione errore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Fusibili . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Display e codici errore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5. Avvertenze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
DARD EUROP
EO
AN
ST
I
URITY FOG
DE
SEC
V
F
PREVENTION
W
ME
I
RI
TH
1. Begin here – very important if you are installing a Fog Cannon for the first time
Please read the installation manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Removal of cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Mounting the brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2. Connections, setting and test
Printed circuit board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Typical installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dipswitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Fog volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Connecting the batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installation of the fluid container . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3. Hand over
Information and registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Service and maintenance agreement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4. In case of faults
Fault finding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Status indicators/fault codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5. Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
07/10/11
17.49
3
PROTECT™ 600i/1100i/2200i
Contenido
CIÓN MED
VEN
IA
N
ESTE PRODUCTO ES
CONFORME CON LA
EN 50131-8
M
A
NORMA EUROPEA
A DE SE
IEBL
GU
R
ROPEA SOBR
EU
E
E
PR
N
TE
NO
R
1. Empezar por aquí – importante si es su primera instalación de un generador de niebla
Por favor lea detenidamente el manual de instalación . . . . . . . . . . . . . . . . . . . . . . . . 4
Retire las cubiertas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Montaje de los anclajes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Colocación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Instrucciones de seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cableado . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2. Conexiones, configuración y prueba
Placa de circuito impreso (PCB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Instalación típica . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dipswitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Entradas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Volumen de niebla . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Conexión de la batería . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Se instala el recipiente . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Prueba . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3. Entrega
Información y registro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Acuerdo de servicio y mantenimiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4. En caso de averías
Comprobación de la avería . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Fusibles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Indicadores de estado/códigos de avería . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5. Advertencias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
AD
ID
E
DK Indholdsfortegnelse
SK NORM
PÆI
F
RO
YVERISIKRIN
OPF YLDER
NOR MEN
EN 50131-8
FOR TÅGESIKRING
G
ER
T
OR
ÅGEKAN
DT
ON
ME
EU
1. Start her – Særlig vigtigt, når du monterer første gang
Start med at læse manualen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Afmontering af kabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Montering, beslag og mål . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Placering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Sikkerhedsinstrukser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Kabelføring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2. Tilslutning, indstillinger og test
Printkort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Typisk installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dipswitche/tågetider . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Indgange, oversigt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Tågevolumen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Tilslutning af batterier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Montering af væskedunk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3. Aflevering
Information og registrering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Serviceaftale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4. I tilfælde af fejl
Fejlfinding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Sikringer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Statusindikatorer/fejlkoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5. Advarsler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4
PROTECT™ 600i/1100i/2200i
1. Begin here - very important if you are installing a Fog Cannon for the first time
F:
I:
E:
DK:
GB
F
I
E
DK
GB
F
Commencez ici – Particulièrement important quand vous installez un canon à fumée pour la première fois
Importante: per chi installa un generatore di nebbia per la prima volta
Empezar por aquí – importante si es su primera instalación de un generador de niebla
Start her – Særlig vigtigt, når du monterer første gang
As an installer you must participate in a
PROTECT training session.
1
Avant l’installation, les installateurs doivent suivre
les cours techniques de PROTECT.
Suggeriamo la partecipazione ad un corso di
Formazione organizzato da PROTECT ITALIA
Como instalador, debe participar en un curso de
capacitación de PROTECT.
Som installatør skal du have deltaget i et PROTECT
træningskursus.
When unpacking the Fog Cannon please read the
installation manual carefully.
2
Quand vous déballez l’appareil, lisez s’il vous plait le
manuel d’installation avec attention.
I
Leggere attentamente il manuale installatore prima di
iniziare l’installazione.
E
Antes de desembalar el equipo, por favor lea
detenidamente el manual de instalación.
DK
Før du pakker tågekanonen ud, bedes du læse installationsmanualen omhyggeligt.
GB
Removal of cover.
F
Démontage du capot.
I
Rimozione del coperchio.
E
Retire las cubiertas.
DK
Afmontering af kabinet.
3
5
PROTECT™ 600i/1100i/2200i
GB
4
Measurements for installation of the Fog Cannon.
F
Dimensions du générateur de fumée lors du montage.
I
Dimensioni del generatore nebbiogeno.
E
PROTECTTM 600i PROTECTTM 1100i PROTECTTM 2200i
Medidas del generador de niebla.
DK
Tågekanonens ophængsmål.
GB
5
Mounting the brackets. Use enclosed template.
F
Montage du support de fixation. Utilisez le gabarit
fourni.
I
Montaggio delle staffe. Utilizzare la dima in dotazione.
E
Montaje de los anclajes. Use plantilla adjunta.
DK
Montering af beslag. Brug vedlagte skabelon.
GB
F
I
E
During the installation the generator hangs on the 4
screws before it is pushed into position.
Pendant l’installation, le générateur est suspendu entre
4 supports avant qu’il soit poussé dans sa position
finale.
Durante l’installazione il generatore rimane appeso
alle 4 viti. Ultimati i collegamenti, spingerlo nella posizione
definitiva di lavoro.
Durante la instalación, el generador colgará de los 4
tornillos antes de ser colocado en su posición.
DK
Under installationen hænger maskinen i 4 skruer,
inden den skubbes helt på plads.
6
X
475 mm
475 mm
633 mm
Y
332 mm
332 mm
352 mm
Z
154 mm
174 mm
172 mm
KG
12,6
16
24,8
6
GB
To ensure the best possible coverage the fog needs
free passage.
F
PROTECT™ 600i/1100i/2200i
7
Pour assurer une couverture optimale, la fumée doit
être expulsée sans encombre.
I
Il generatore di nebbia deve essere posizionato in modo
da coprire istantaneamente i beni da proteggere.
E
DK
GB
Para asegurar una cobertura óptima, es importante
que la niebla circule libremente al dispararse.
For at sikre bedst mulig dækning skal tågen affyres,
så den har et frit forløb.
he Fog Cannon must be placed to ensure
T
immediate coverage of possible access points
8
F
lacer le générateur de fumée de façon à couvrir
P
immédiatement toute voie d’accès.
I
Per assicurare una buona copertura, la nebbia non deve
incontrare ostacoli. Sono disponibili vari ugelli per l’emissione
della nebbia con inclinazioni e direzioni diverse.
30°
E
l generador de niebla debe colocarse de manera que las
E
posibles vías de acceso se cubran inmediatamente.
DK
Tågekanonen placeres, så mulige adgangsveje
dækkes øjeblikkeligt.
GB
F
revent sabotage by installing the Fog Cannon
P
correctly out of reach and avoid blocking exit routes.
Eviter les risques de sabotage en installant le générateur
correctement hors de portée; ne pas couvrir les voies
de fuite.
I
Evitate la possibilità di sabotaggio installando il generatore di
nebbia fuori portata. La nebbia non deve ostruire le vie di fuga
E
Evite la posibilidad de sabotaje mediante una
instalación correcta y fuera de alcance, y evite cubrir
las posibles vías de escape.
DK
Undgå sabotagemulighed ved korrekt montage uden
for rækkevidde samt undgå at dække flugtveje.
9
7
PROTECT™ 600i/1100i/2200i
GB
10
Min. installation distance from objects.
F
Ecart minimal entre le générateur et d’autres objets.
I
Distanza minima per ottenere un buon effetto.
E
Distancia de instalación mín. respecto a otros objetos.
DK
Min. installationsafstand til genstande.
GB
F
For horizontal mounting, place the Fog Cannon as
shown in the picture.
11
Montage horizontal: installer le générateur de fumée
comme illustré.
I
Posizionamento corretto e distanze minime da pareti e
soffitti.
E
En caso de montaje horizontal, el generador de niebla
debe colocarse tal como aquí se indica.
DK
Ved horisontal montage placeres tågekanonen som
vist her.
GB
F
Min. safety distance
– risk of scalding.
12
Distance de sécurité minimum
– danger d’échaudage.
I
Distanza minima di sicurezza
- ATTENZIONE: pericolo ustione.
E
Distancia de seguridad mínima
– peligro de quemaduras.
DK
Min. sikkerhedsafstand
- fare for skoldning.
Min. 35 cm.
8
GB
F
I
E
DK
Avoid unintentional fog emission
– remove the fluid container during installation.
PROTECT™ 600i/1100i/2200i
13
Enlever le réservoir de liquide pendant le montage
pour éviter toute émission de fumée.
Togliere il contenitore del fluido durante l’installazione
per evitare la generazione accidentale di nebbia.
Evite los disparos accidentales – retire el recipiente
de líquido durante la instalación.
Undgå utilsigtet affyringer
– fjern væskedunken under montage.
GB
Cabling of PROTECT TM 600i/1100i/2200i.
14
F
Câblage par PROTECT TM 600i/1100i/2200i.
I
Cablaggio del sistema PROTECT TM 600i/1100i/2200i
Collegamento al sistema d’allarme.
E
Cableado del sistema PROTECT TM 600i/1100i/2200i.
DK
LOW VOLTAGE
Kabelføring af PROTECT TM 600i/1100i/2200i.
GB
Cabling of PROTECT TM 600i/1100i/2200i.
15
F
Câblage par PROTECT TM 600i/1100i/2200i.
I
Cablaggio del sistema PROTECT TM 600i/1100i/2200i
Collegamento alla rete di alimentazione elettrica.
E
Cableado del sistema PROTECT TM 600i/1100i/2200i.
DK
Kabelføring af PROTECT TM 600i/1100i/2200i.
HIGH VOLTAGE
9
PROTECT™ 600i/1100i/2200i
2. Connections, setting and test
F:
I:
Connections, réglages et tests
Collegamenti, impostazioni e test
E:
Conexiones, configuración y prueba
DK: Tilslutning, indstillinger og test
GB: Printed circuit board F: Carte à circuit imprimé (PCB) I: Circuito stampato
E: Placa de circuito impreso (PCB) DK: Printkort
GB: Voltage F: Tension I: Alimentazione E: Tensión DK: Spænding
PROTECT™ 600i
PROTECT™ 1100i
PROTECT™ 2200i
230 V ac
230 V ac
230 V ac
GB: Effect F: Effet I: Assorbimento E: Consumo DK: Effekt
PROTECT™ 600i
PROTECT™ 1100i
PROTECT™ 2200i
1050 W
1350 W
1680 W
Typical Installation
Installation type
Installazione tipica
Instalación típica
Typisk Installation
GB: Connection to alarm
panel (typical installation)
Primary trigger is NO
(normal open) and
a service switch is
installed.
F:
Connexion au tableau
d’alarme (installation
type).
Les signaux de
déclenchement
primaires sont NO
(normalement ouverts)
et un commutateur de
service est installé.
I:
Connessione alla centrale di allarme.
I segnali di attivazione
sono in tensione 12 Volt
di tipo NA (normalmente assenti).
E:
Conexión al panel de
alarma (instalación
típica).
Las señales de activación primarias son
del tipo NA (normalmente abierto) y hay un
interruptor de servicio
instalado.
DK: Tilslutning til alarmpanel
(typisk installation).
Primær trigger signaler
er NO (normal open),
og serviceafbryder er
installeret.
GB:
F:
I:
E:
DK:
OFF
ON 1
ARM
12 V
Output
Tamper
Prim.
Sec.
–
+
–
+
–
+
–
+
–
+
+
–
10
COM.
NC
NO
COM.
NC
NO
COM.
NC
NO
Disable
Fire
Dipswitch
Fluid Rly.
Fault Rly.
Fog Rly.
Service
Fog Generator
Service Switch
PRIMARY TRIGGER NORMALLY OPEN
+ 12 V
+ 12 V
+
– 12 V
Tamper
Motion
PIR
Gnd
Contact closes when alarm is tripped
Alarm Signal
Contact Closed During Daytime
Disable Signal
Zone Swich Position
Zone Tamper
Zone Fluid
Zone Fault
Zone Fog
Alarm System
10
PROTECT™ 600i/1100i/2200i
Typical Installation
Installation type
Installazione tipica
Instalación típica
Typisk Installation
GB: Connection to
alarm panel (typical installation).
All triggers are NC
(normal closed).
F:
Connexion au
tableau d’alarme
(installation type).
Tous les signaux
de déclenchement
sont NC (normalement fermés).
I:
Connessione alla
centrale di allarme.
I segnali di attivazione sono in
tensione 12 Volt di
tipo NC (normalmente presenti).
E: Conexión al panel
de alarma (instalación típica). Todas las señales de
activación son del
tipo NC (normalmente cerrado).
DK: Tilslutning til
alarmpanel (typisk
installation). Alle
trigger signaler
er NC (normal
closed).
GB:
F:
I:
E:
DK:
OFF
ON 1
ARM
12 V
Output
Tamper
Prim.
Sec.
–
+
–
+
–
+
–
+
–
+
+
–
10
COM.
NC
NO
COM.
NC
NO
COM.
NC
NO
Disable
Fire
Dipswitch
Fluid Rly.
Fault Rly.
Fog Rly.
Service
Fog Generator
Service Switch
Alarm System
+ 12 V
+ 12 V
+
– 12 V
Tamper
Motion
PIR
Gnd
Contact opens when alarm is tripped
Alarm Signal
Contact Closed During Daytime
Disable Signal
Zone Tamper
Zone Fluid
Zone Fault
Zone Fog
ALL TRIGGER SIGNALS NORMALLY CLOSED
PROTECT™ 600i/1100i/2200i
11
12
PROTECT™ 600i/1100i/2200i
1. GB: Dipswitch F: Dipswitch I: Dipswitches E: Dipswitch DK: Dipswitch
DIP
GB: Function
F: Fonction
I: Funzione
E: Función
DK: Funktion
Desactivar calentamiento
ON = el elemento térmico
se desconecta
Heat disable
ON = varme afbrydes,
når disable aktiveres
1
Heat disable
On = The heating element disconnects if disable is activated
Chauffage désactivé
On = l’élément chauffant s’éteint
si “disable” est activé
ON = l’elemento termico è
disattivato quando è attivo il
comando “disable”.
Lasciare in posizione OFF
2
Fog time
Durée de la fumée
Temporizzazione
emissione nebbia
Tiempo de niebla
Tågetid
Tiempo de niebla
Tågetid
Tiempo de niebla
Tågetid
3
Fog time
Durée de la fumée
Temporizzazione
emissione nebbia
4
Fog time
Durée de la fumée
Temporizzazione
emissione nebbia
5
Arm*
Arm*
Arm*
Arm*
Arm *
6
Primary*
Primaire*
Primario*
Primario*
Primær *
7
Secondary*
Secondaire*
Secondario*
Secundario*
Sekundær *
8
Fire-alarm delay**
Temporisation de l’avertisseur
d’incendie**
Ritardo allarme incendio**
Retraso alarma incendio**
Brandmelder forsinkelse **
9
Reserved. Leave in OFF
position
Réservé.
Doit rester sur la position OFF
Riservato.
Lasciare in posizione OFF
Reservado. Mantener en posición
OFF
Reserveret.
Sættes i OFF position
10
Error indicator
On = Beeper connected
Détection d’erreur
On = bipeur activé
Segnalatore di errore
ON = buzzer inserito
Indicador de fallo
On = sonido conectado
Fejlmelder
ON = lydgiver tilkoblet
* ON = normal open / normal ouvert / normalmente assente / normal abierta / aktiv slutte.
OFF = normal closed / normalement fermé / normalmente presente / normal cerrada / aktiv bryde.
** ON = delay is active / retraso activo / ritardo attivo / retraso se activa / forsinkelse aktiv.
GB: Inputs F: Entrées I: Ingressi E: Entradas DK: Indgange
Tamper
12V
ARM
Primary
Sec.
DIS.
Fire
GB
F
I
E
DK
Potential-free switches activate
(open) when the covers are removed. They can be used in the
alarm system’s tamper circuit.
Des contacts libres sont installés
et sont activés (ouverts) lorsque
les couvercles sont enlevés.
Ils peuvent être utilisés dans
le circuit tamper du système
d’alarme.
I contatti puliti si attivano (aprono)
alla rimozione del coperchio. Si
possono collegare al circuito
antisabotaggio del sistema di
allarme.
Las conexiones libres de potencial se activan (se abren) al
desmontarse las tapas y pueden
emplearse en el circuito tamper
de la instalación de alarma.
Der er monteret potentialefri kontakter, som aktiveres
(åbner), når dækslerne afmonteres. Disse kan benyttes i
alarmanlæggets tamper kreds.
Built-in 12V supply system that
delivers 0.1A – mainly to supply
the secondary circuit, e.g. a PIR
sensor.
Alimentation 12V intégrée qui
peut fournir 0,1A principalement
pour alimenter le circuit secondaire, tel qu’un capteur PIR.
Alimentazione 12V 0,1 A per
alimentare il circuito secondario,
ad esempio un sensore IR come
sensore di verifica, o da utilizzare
nel caso manchi il comando 12
Volt dal sistema d’allarme e sia
solo disponibile un comando
relè
Alimentación de 12V para suministro de 0.1A al circuito secundario, p. ej. un sensor PIR.
Indbygget 12V forsyning, som
kan levere 0.1A til hovedsageligt at forsyne sekunddærkredsen, eks. en PIR-sensor.
Can be activated permanently by
selecting an active break signal
and by not connecting anything
to the terminals.
Peut être activé en permanence
en choisissant comme signal un
signal d’interruption actif et en
évitant de connecter quoi que ce
soit aux bornes.
Può essere attivato permanentemente impostandolo come segnale di interruzione attiva e non
collegandoci nulla ai terminali.
Se activa permanentemente seleccionando la señal como señal
de ruptura activa sin conectar
nada a los bornes.
Kan aktiveres permanent ved
at vælge signalet som et aktivt bryde signal og undlade at
forbinde noget til klemmerne.
The primary trigger signal is normally taken from the alarm system and activated from it in case
of a break-in.
Le signal de déclenchement primaire se fait, en règle générale,
à partir du système d’alarme qui
l’active en cas d’effraction.
Il segnale di attivazione primaria è
derivato dalla centrale d’ allarme
quando rileva un’intrusione.
Generalmente, la señal de activación primaria procede del
sistema de alarma y se activa
desde aquí en caso de robo.
Det primære udløsesignal
tages som en hovedregel fra
alarmsystemet og aktiveres
herfra ved indbrud.
The secondary trigger signal is
normally taken from a verifying
sensor such as a room sensor or
a door switch.
Le signal de déclenchement secondaire se fait normalement à
partir d’un capteur de vérification
tel qu’un détecteur de mouvement ou d’un contact de porte.
Generalmente il segnale di attivazione secondaria è derivato
da un sensore volumetrico della
stanza protetta (doppio consenso per attivare il generatore
di nebbia).
Normalmente, la señal de activación secundaria procede de un
sensor verificador, p.ej un sensor
de sala o un contacto de puerta.
Det sekundære udløsesignal
tages normalt fra en verificerende sensor såsom rumføler
eller en dørkontakt.
The disable function can be used
to stop the Fog Cannon when it is
producing fog. The signal is connected to the alarm, so the Fog
Cannon is dis­connected when
the alarm is disconnected.
“Disable” peut être utilisé pour
arrêter le générateur de fumée
lorsque celui-ci est en train
d’émettre de la fumée. Le signal
est relié à l’alarme de telle sorte
que le générateur de fumée est
désactivé lorsque l’alarme est
désactivée.
Questo comando blocca la
generazione di nebbia mentre
la macchina è attiva e quando il
sistema d’allarme non è inserito
(locali occupati)
La función desactivar puede emplearse para detener el generador
de niebla. La señal se conecta a
la alarma de manera que cuando
la alarma está desconectada,
el generador de niebla también
queda desconectado.
Disable bruges til at stoppe
tåge­kanonen, når den er i gang
med at producere tåge.
Signal forbindes til alarm, så
tåge generatoren er frakoblet,
når alar­men er frakoblet.
Connection of 12 V DC, N/O signal from the fire alarm system.
In case of a fire alarm this signal
will disconnect the Fog Cannon
as long as the signal is active.
Also, the Fog Cannon will activate a sound signal and report an
error on the system error relay.
Raccordement du 12V c.c., signal N/O du système d’alarme
incendie.
Lorsque
l’alarme
d’incendie se déclenche, ce signal arrête le générateur de fumée
tant que le signal reste actif. Simultanément, le générateur de
fumée produit un signal sonore
et envoie un message d’erreur au
relais du système d’erreurs.
Comando in ingresso 12V cc
dalla centrale di rilevazione incendio. In questo modo, in caso
di allarme incendio, il generatore
di nebbia viene disabilitato per
tutto il tempo di presenza del
segnale. Contemporaneamente il
generatore produrrà un suono di
allarme e attiverà il relè di errore
di sistema.
Conexión de la señal 12 V CC,
NA del sistema antiincendio.
Cuando se produce una alarma
de incendio, esta señal interrumpe el generador de niebla,
mientras la señal esté activa. Al
mismo tiempo, el generador de
niebla emite una señal sonora y
envía un mensaje de fallo al relé
de fallo.
Tilslutning af 12 V DC, N/O signal fra brandalarmanlægget.
Når der opstår brandalarmtilstand, vil dette signal afbryde
tågekano­nen, så længe signalet er aktivt. Samtidig vil tågekanonen afgive lydsignal og
melde fejl på systemfejlrelæet.
13
PROTECT™ 600i/1100i/2200i
GB: Fog Volume F: Volume de fumée I: Volume di nebbia E: Volumen de niebla DK: Tågevolumen
GB
In the tables below the fog volume mentioned is based on the industry
standard of security fog - and in the brackets the new standard according to the current EU standard EN 50131-8. The Fog Cannons of
PROTECT meets the requirements of EN 50131-8 (see certificate in this
manual). It’s important to perform a test firing of the installation - and
not only rely on the calculation of cubic metres. A change in visibility
is gained through longer/shorter time with fog (adjustment of the unit),
more/less Fog Cannons and/or different placing of the unit(s).
F
Dans les tableaux ci-dessous les volumes de fumée exprimés sont basés sur les standards de l’industrie de la Protection par la fumée, entre
parenthèses les nouvelles valeurs en fonction de la EN 50131-8. Les
générateurs de fumée PROTECT répondent à la norme EN 50131-8
(voir les certificats dans ce manuel).
Il est important de réaliser un tir réel et complet pour validation
l’installation - et ne pas s’appuyer seulement sur le calcul du volume.
Un changement de la visibilité est obtenu en augmentant ou réduisant
le temps de (réglage du temps de production sur l’appareil) plus ou
moins de générateurs, aux emplacements différents améliore la protection.
E
En las tablas que hay a continuación, el volumen de niebla indicado se
basa en el estándar de la industria de la niebla de seguridad – y entre
paréntesis, los nuevos estándares de acuerdo con la actual normativa
de la UE norma EN 50131-8. Los generadores de niebla PROTECT
cumplen con los requisitos de las normas Europeas EN 50131-8 (vea
certificado en este manual). Es importante realizar un disparo en la instalación – y no confiar únicamente en el cálculo de los metros cúbicos.
Un cambio en la visibilidad se consigue mediante un tiempo de disparo
mayor/menor de niebla (ajustable en el equipo), más/menos Generadores de Niebla y/o diferente ubicación de la/s unidad/es.
DK
Tallene i skemaerne nedenfor angiver tågevolumen ud fra tågeindustriens standarder - og i parentes den nye standard ifølge gældende
EU-norm EN 50131-8.
En ændring i sigtbarheden opnås ved længere/kortere tågetid, flere/
færre tågekanoner og/eller ændret placering. PROTECT’s tågekanoner opfylder kravene i EU-normen EN 50131-8 (se certifikat bagest i
manualen). Det er altid vigtigt at teste installationen i praksis og ikke
kun gå ud fra kubikmeterudregning.
I
Nella tabella riportata in basso il volume di nebbia è quantificato sugli
standard industriali definiti per la nebbia di sicurezza – e tra parentesi
lo Standard Europeo EN 50131-8. I sistemi nebbiogeni PROTECT soddisfano a pieno i requisiti dello Standard Europeo EN 50131-8 (vedi
certificato in questo manuale). È fondamentale eseguire un test finale
sul luogo dell’installazione, e non basarsi esclusivamente su di un calcolo treorico dei metri cubi da saturare. Una variazione della visibilità è
ottenibile tramite un maggiore/minore tempo di emissione della nebbia (vedi tabella di programmazione), un numero maggiore/minore di
sistemi nebbiogeni e/o una differente disposizione degli stessi.
PROTECTTM 600i
Dip Setting / Réglage DIP / Posizione DIP
Dip Configuración / Dip instillinger
Fog Time / Durée de la fumée / Tempo di
erogazione nebbia / Tiempo de niebla /
Tågetid
Fog Volume / Volume de fumée /
Volume di nebbia prodotto
Volumen de niebla / Tågevolumen
Dip 2
Dip 3
Dip 4
OFF
OFF
OFF
demo
m³/pied³/pies³
-
ON
OFF
OFF
20s
290 (145*)
OFF
ON
OFF
40s
540 (270*)
ON
ON
OFF
60s
700 (350*)
OFF
OFF
ON
60s + 1 min.
775 (385*)
ON
OFF
ON
60s + 4 min.
1050 (525*)
OFF
ON
ON
60s + 9 min.
1700 (850*)
ON
ON
ON
30s – turbo
600 (300*)
*M3 according to the current EU standard EN 50131-8.
*M3 selon la norme européenne EN 50131-8
*M3 secondo l’attuale norma europea EN 50131-8.
*M3 de acuerdo a la actual norma europea EN 50131-8
*M3 i henhold til den gældende EU standard EN 50131-8.
PROTECT 600i:
GB: Total time in max. pulse mode = 10 min. 60 sec. + pulse shots. Total
fog production = 1700 m3 (850*). Total capacity in the fluid container = 3
complete sequence in pulse mode.
F: Durée totale en mode pulse = 10 min. (60 sec. + tirs en mode pulse).
Volume total de fumée = 1700 m3 (850*). Capacité totale d’une recharge de
liquide: 3 séquences complètes en mode pulse.
I: Tempo massimo di erogazione in un ciclo con funzione ad impulsi =
10minuti (1 minuto + erogazioni ad impulsi) Produzione totale nebbia =
1700 m3 (850*). Capacità massima di un contenitore di fluido = 3 sequenze
complete (vedi sopra).
E: Tiempo total máximo en modo de pulsos = 10 min. 60 seg. + disparos
de pulso. Producción total de niebla = 1700 m3 (850*). Capacidad total del
depósito de fluido = 3 secuencias completas en modo de pulsos.
DK: I alt ca. 10 min. ved maks. pulsfunktion. 60 sek. + pulsskud. Total
produktion = 1700 m3 (850*) tåge. Total kapacitet = 3 komplette sekvenser
m/puls i en dunk.
14
PROTECT™ 600i/1100i/2200i
PROTECTTM 1100i
Dip Setting / Réglage DIP / Posizione DIP
Dip Configuración / Dip instillinger
Fog Time / Durée de la fumée / Tempo di
erogazione nebbia / Tiempo de niebla /
Tågetid
Fog Volume / Volume de fumée /
Volume di nebbia prodotto
Volumen de niebla / Tågevolumen
Dip 2
Dip 3
Dip 4
OFF
OFF
OFF
demo
demo
ON
OFF
OFF
15s
500 (250*)
OFF
ON
OFF
30s
875 (435*)
ON
ON
OFF
45s
1200 (600*)
OFF
OFF
ON
60s
1300 (650*)
ON
OFF
ON
60s + 4 min.**
1700** (850*)
OFF
ON
ON
-
-
ON
ON
ON
-
-
*M according to the current EU standard EN 50131-8.
*M3 selon la norme européenne EN 50131-8
*M3 secondo l’attuale norma europea EN 50131-8.
*M3 de acuerdo a la actual norma europea EN 50131-8
*M3 i henhold til den gældende EU standard EN 50131-8.
3
**Not useable on 115/130 V markets. See supplement to this manual for low volt markets.
**Non applicable pour les Pays en 115/130 Volts. Voir le supplément à ce manuel pour les Pays à faible voltage.
**Non utilizzabile nei paesi con tenisone domestica di 115/130 V. Vedi nel supplemento manuale per basso voltaggio.
**No utilizable en países cuyo voltaje sea de 115/130 V. Vea el anexo a este manual para los mercados con bajo voltaje
**Kan ikke bruges i lande med 115/130 V. Se tillæg til denne manual for lande med lav volt.
PROTECT 1100i:
GB: Total time in pulse mode = 5 min. 60 sec. + pulse shots. Total fog production = 1700 m3 (850*). Total capacity in the fluid container = 3 complete
sequence in pulse mode.
F: Durée totale en mode pulse = 5 min. (60 sec. + tirs en mode pulse).
Volume total de fumée = 1700 m3 (850*). Capacité totale d’une recharge de
liquide: 3 séquences complètes en mode pulse.
I: Tempo massimo di erogazione in un ciclo con funzione ad impulsi = 5
minuti (1 minuto + erogazioni ad impulsi) Produzione totale nebbia = 1700
m3 (850*). Capacità massima di un contenitore di fluido = 3 sequenze complete (vedi sopra).
E: Tiempo total en modo de pulsos = 5 min. 60 seg. + disparos de pulso.
Producción total de niebla = 1700 m3 (850*). Capacidad total del depósito
de fluido = 3 secuencias completas en modo de pulsos.
DK: I alt ca. 5 min. med pulsfunktion. 60 sek. + pulsskud. Total produktion
= 1700 m3 (850*) tåge. Total kapacitet = 3 komplette sekvenser m/puls i en
dunk.
PROTECTTM 2200i
Dip Setting / Réglage DIP / Posizione DIP
Dip Configuración / Dip instillinger
Fog Time / Durée de la fumée / Tempo di
erogazione nebbia / Tiempo de niebla /
Tågetid
Fog Volume / Volume de fumée /
Volume di nebbia prodotto
Volumen de niebla / Tågevolumen
Dip 2
Dip 3
Dip 4
OFF
OFF
OFF
demo
demo
ON
OFF
OFF
20s
900 (450*)
OFF
ON
OFF
40s
1800 (900*)
ON
ON
OFF
60s
2700 (1350*)
OFF
OFF
ON
70s
2875 (1435*)
ON
OFF
ON
30s + 6 min.**
2500** (1250*)
OFF
ON
ON
60s + 10 min.**
3700** (1850*)
ON
ON
ON
-
-
*M3 according to the current EU standard EN 50131-8.
*M3 selon la norme européenne EN 50131-8
*M3 secondo l’attuale norma europea EN 50131-8.
*M3 de acuerdo a la actual norma europea EN 50131-8
*M3 i henhold til den gældende EU standard EN 50131-8.
**Not useable on 115/130 V markets. See supplement to this manual for low volt markets.
**Non applicable pour les Pays en 115/130 Volts. Voir le supplément à ce manuel pour les Pays à faible voltage.
**Non utilizzabile nei paesi con tenisone domestica di 115/130 V. Vedi nel supplemento manuale per basso voltaggio.
**No utilizable en países cuyo voltaje sea de 115/130 V. Vea el anexo a este manual para los mercados con bajo voltaje
**Kan ikke bruges i lande med 115/130 V. Se tillæg til denne manual for lande med lav volt.
PROTECT 2200i:
GB: Total time in pulse mode = 6,5 min. 30 sec. + pulse shots. Total fog production = 2500 m3 (1250*). Total capacity in the fluid container = 4 complete
sequence in pulse mode.
F: Durée totale en mode pulse = 6,5 min. (30 sec. + tirs en mode pulse).
­Volume total de fumée = 2500 m3 (1250*). Capacité totale d’une recharge de
liquide: 4 séquences complètes en mode pulse.
I: Tempo massimo di erogazione in un ciclo con funzione ad impulsi = 6,5
minuti (30 sec. + erogazioni ad impulsi) Produzione totale nebbia = 2500 m3
(1250*). Capacità massima di un contenitore di fluido = 4 sequenze complete
(vedi sopra).
E: Tiempo total en modo de pulsos = 6,5 min. 30 seg. + disparos de pulso.
Producción total de niebla = 2500 m3 (1250*). Capacidad total del depósito
de fluido = 4 secuencias completas en modo de pulsos.
DK: I alt ca. 6,5 min. med pulsfunktion. 30 sek. + pulsskud. Total produktion
= 2500 m3 (1250*) tåge. Total kapacitet = 4 komplette sekvenser m/puls i en
dunk.
PROTECT 2200i:
GB: Total time in pulse mode = 11 min. 60 sec. + pulse shots. Total fog production = 3700 m3 (1850*). Total capacity in the fluid container = 3 complete
sequence in pulse mode.
F: Durée totale en mode pulse = 11 min. (60 sec. + tirs en mode pulse). Volume total de fumée = 3700 m3 (1850*). Capacité totale d’une recharge de
liquide: 3 séquences complètes en mode pulse.
I: Tempo massimo di erogazione in un ciclo con funzione ad impulsi = 11
minuti (1 minuto + erogazioni ad impulsi). Produzione totale nebbia = 3700 m3
(1850*). Capacità massima di un contenitore di fluido = 3 sequenze complete
(vedi sopra).
E: Tiempo total en modo de pulsos = 11 min. 60 seg. + disparos de pulso.
Producción total de niebla = 3700 m3 (1850*). Capacidad total del depósito
de fluido = 3 secuencias completas en modo de pulsos.
DK: I alt ca. 11 min. med pulsfunktion. 60 sek. + pulsskud. Total produktion
= 3700 m3 (1850*) tåge. Total kapacitet = 3 komplette sekvenser m/puls i en
dunk.
GB:
F:
I:
E:
DK:
Pulse
Impulsion
Impulsivo
Pulsos
Puls
60 sec. fog
Fog output
Fog output
Fog output
Fog output
Fog output
PROTECTTM Pulse Effect
Break
Break
Break
Break
Break
15
PROTECT™ 600i/1100i/2200i
GB
F
I
E
DK
GB
F
I
E
DK
GB
F
I
E
DK
GB
F
I
E
DK
GB
F
I
E
DK
Check the control signals before testing.
16
Contrôler les signaux de commande avant de tester.
Controllare i segnali di attivazione prima di iniziare Il test.
Controle las señales de mando antes de realizar el ensayo.
Kontroller styresignaler før afprøvning.
Connect the battery. One battery measures 97 x 43 x 51 mm.
17
Brancher la batterie. Dimension d’une batterie: 97 x 43 x 51 mm.
Collegamento delle batterie.
Dimensioni di una batteria: mm 97 x 43 x 51.
Conexión de la batería. Una batería mide 97 x 43 x 51 mm.
Batteriet tilsluttes. Et batteri måler 97 x 43 x 51 mm.
Install the fluid container and attach the metal cover.
18
Installez la recharge de fluide et fixez le capot en métal.
Installare il contenitore del liquido e chiudere il coperchio.
Fije el depósito de fluido y la tapa metálica.
Installer væskedunken og sæt metalkabinettet på.
Remember to heat the system before testing.
19
Ne pas oublier le temps de chauffe avant de tester.
Permettere al sistema di riscaldarsi prima di eseguire il test.
Recuerde el tiempo de calentamiento antes de realizar el ensayo.
PROTECTTM 600i PROTECTTM 1100i PROTECTTM 2200i
Husk opvarmningstid før test.
Full-scale test: Remember that the test must include the entire
alarm installation.
Test en situation réelle: Ne pas oublier d’inclure l’ensemble de
l’installation d’alarme dans l’essai.
Test completo: il test deve includere tutto l’impianto d’allarme.
Ensayo completo: Recuerde que el ensayo debe incluir toda la
instalación de alarma.
Fuld skala test: Husk: testen skal omfatte hele
alarminstallationen.
Min.
20
10-15
15-25
30-45
16
PROTECT™ 600i/1100i/2200i
3. Hand over
F: Remise I: Consegna dell’impianto E: Entrega DK: Aflevering
GB
F
Check the fluid level after testing (hand over
the Fog Cannon with a full fluid container).
Contrôler le niveau de liquide après l’essai (remettre le
générateur de fumée le réservoir rempli).
I
Controllare il livello di liquido nel contenitore dopo il
test. Consegnare al cliente il generatore di nebbia con il
contenitore pieno.
E
Controle el nivel del líquido después del ensayo
(entregue el generador de niebla con el recipiente de
líquido lleno).
DK
21
Kontrollér væskestanden efter test (aflever tåge­
kanonen med fuld væskedunk).
GB
22
Remember to put warning labels on the windows.
F
I
E
Ne pas oublier de bien placer les autocollants
d’avertissement sur les fenêtres.
Apporre le etichette di avviso sulle superfici vetrate
(punti di accesso).
No olvide colocar las etiquetas de advertencia en las
ventanas.
DK
Husk påsætning af advarselsmærkater på vinduerne.
GB
F
I
E
DK
Before leaving the installation all users must be
instructed in how the Fog Cannon works.
L’installation finie, l’installateur doit instruire tout utilisateur
dans le fonctionnement du générateur de fumée.
Al termine tutto il personale del locale deve essere
informato sul funzionamento del generatore nebbiogeno.
Antes de abandonar la instalación, asegúrese de que
todos los usuarios han sido instruidos en el manejo del
generador de niebla.
Før du forlader installationen, skal alle brugere
instrueres i hvorledes tågekanonen virker.
23
17
PROTECT™ 600i/1100i/2200i
GB
F
I
E
DK
The users must be informed that further information
can be found on www.ProtectGlobal.com
24
Les utilisateurs doivent être informés de la possibilité
d’obtenir plus de renseignements sur le site
www.ProtectGlobal.com
Informare il cliente che ulteriori informazioni
Sono disponibili sul sito www.ProtectGlobal.com
Informe a los usuarios que pueden consultar
www.ProtectGlobal.com para mayor información.
Brugerne skal oplyses, at flere informationer kan
findes på www.ProtectGlobal.com
GB
25
Complete the warranty sheet and send it to PROTECT.
F
Remplir le certificat de garantie et l’envoyer à PROTECT.
I
La garanzia deve essere compilata ed inviata a PROTECT.
E
La hoja de garantía debe rellenarse y enviarse
a PROTECT.
DK
Garantibeviset udfyldes og sendes til PROTECT.
GB
F
I
E
DK
Complete the sheet for the authorities and send it to
your local police and fire department.
Remplir la notification aux autorités publiques et
l’envoyer à la police et au corps des pompiers locaux.
Compilare il modulo per le autorità locali ed inviarlo
agli organi di Polizia competenti e ai Vigili del Fuoco.
La hoja informativa para las autoridades debe rellenarse y enviarse a la policía local y al departamento
de bomberos.
Meddelelse til myndigheder udfyldes og sendes til
det lokale politi og brandvæsen.
26
18
GB
F
I
E
DK
Finally, a contract of service must be made, which
should contain an agreement for min. one test a year.
PROTECT™ 600i/1100i/2200i
27
Finalement, dresser un contrat d’entretien qui doit
comprendre au minimum un essai par an.
Si suggerisce infine di stipulare con il cliente
un contratto di manutenzione.
Por último, debe firmarse un contrato de servicio que incluya un
acuerdo de 1 prueba anual como mínimo.
Afslutningsvis indgås serviceaftale, som bør
indeholde en aftale om min. 1 årlig test.
GB: Service and maintenance agreement
A service agreement with the customer includes the following: Visually inspect the fog fluid level. Durability: 5 years from
production date in unopened packaging. 2 years from date of
installation. Do not use when discolored! • Check the loading
capability and the age of the batteries • If the batteries are
more than 2 years old they must be replaced • Check if there
is any fault indicated on the Fog Cannon • Check that the
nozzle is clean of foreign bodies • Check if there are any signs
of sabotage and check the sabotage switches • Check that
the verifying sensor is working correctly • Make a full-scaletest, where the interaction between all systems is tested (also
the fire alarm system if there).
F: Recommandations de Service et de Maintenance
Contrat de service avec le client final, celui-ci respectant les
points suivants: Vérifier visuellement le niveau de liquide fumigène. Durée de vie: Sans á partir de ca date de fabrication si
c’emballage n’est pas ouvert. 2 ans á partir de la date d’installation. Ne pas utiliser quand il est décoloré • Vérifier le niveau
de charge et l’âge des batteries • Si les batteries ont plus de
deux ans, elles doivent être remplacées • Vérifier si il n’y a
pas de défaut (message d’erreur sur l’afficheur) sur l’appareil
• Vérifier que la buse ne soit pas obstruée par des “corps
étrangers” • Vérifier qu’il n’y ait pas de signe de malveillance
sur l’appareil et sur les switch • Vérifier le bon fonctionnement
du detecteur de confirmation • Tester l’ensemble de l’installation d’alarme afin de verifier les interferences des différents
appareils entre eux (y compris le SSI si present).
I: Manutenzione
Un tipico contratto di manutenzione con il cliente contempla:
Ispezione visiva del livello di liquido nel contenitore. Durata:
Cinque anni dalla data di produzione con confezione integra.
Due anni dalla data di installazione. Non utilizzare quando
scolorito! • Controllo dello stato delle batterie: se hanno più di
due anni, devono essere sostituite • Verifica di eventuali messaggi di errore sul display • Controllo della pulizia dell’ugello •
Verificare se sono presenti segni di sabotaggio e controllo del
contatto antisabotaggio • Controllo del funzionamento corretto dell’ eventuale sensore di verifica collegato al generatore
di nebbia • Controllo del corretto funzionamento dell’intero
sistema d’ allarme
E: Acuerdo de servicio y mantenimiento
Un acuerdo de mantenimiento con el cliente, que debe incluir
lo siguiente: Inspeccione visualmente el nivel de fluido de niebla. Durabilidad: 5 años a partir de la fecha de producción
para los productos sin abrir. 2 años a partir de la fecha de
instalación. ¡No utilizar en el caso de el fluido haya perdido
su color! • Compruebe la capacidad y la antigüedad de las
baterías • Si las baterías tienen más de dos años de antigüedad, deben ser reemplazadas • Compruebe si hay algún
aviso de avería en el generador de niebla • Compruebe que la
boquilla no está obstruida por objetos extraños • Compruebe
si hay alguna señal de sabotaje y compruebe los interruptores de sabotaje • Compruebe que el sensor de verificación
funciona correctamente • Haga una prueba completa de funcionamiento, donde se compruebe la interacción de todos los
sistemas (incluso el ABA si existe).
DK: Serviceaftale
En serviceaftale med kunden bør min. indeholde: Inspicer
tågevæskestand visuelt. Holdbarhed: 5 år fra produktionsdato
i uåbnet emballage. 2 år fra installationsdato (ved misfarvning
kasseres væsken) • Undersøg batteriernes belastbarhed og
alder • Er batterierne 2 år eller mere, bør de under alle omstændigheder skiftes • Er der eventuelt fejlmeldinger på maskinen? • Er udblæsningsdysen fri for fremmedlegemer? • Er
der tegn på sabotage? Kontroller sabotageswitse • Virker den
verificerende sensor, som den skal? • Foretag en fuld-skalatest, hvor samspillet mellem alle systemer afprøves (også ABA
hvis til stede).
19
PROTECT™ 600i/1100i/2200i
4. In case of faults
F: En cas de défauts I: In caso di funzionamento anomalo E: En caso de averías DK: I tilfælde af fejl
GB:An identified error can be reset by pressing the Reset button for approx. 4 seconds. The button is located in the centre of the circuit board.
F:
Une faute enregistrée est remise à zéro en appuyant pendant environ 4 secondes sur la touche “Reset” qui est située au milieu de la carte électronique.
I:
Un errore segnalato sul display può essere cancellato premendo il pulsante reset per circa 4 secondi. Il pulsante si trova al centro della scheda elettronica.
E:
Para reiniciar un fallo registrado, mantenga pulsado el botón “Reset”, que está situado en el centro de la placa electrónica, aprox. 4 segundos.
DK: En registreret fejl nulstilles ved at trykke på “Reset” knappen, placeret midt på elektronikkortet i ca. 4 sekunder.
GB
F
I
E
DK
1
Identify the error
(see code on the display)
Identifier l’erreur
(voir le code sur l’écran)
Identifica il tipo di errore
(vedi il codice sul display)
Identifique el fallo
(véase el código en el display)
Identificér fejlen
(Se koden i displayet)
2
Find the cause of the error
Trouver la cause de l’erreur
Individua la causa dell’errore
Determine la causa del fallo
Find årsagen til fejlen
3
Correct the cause of the error
Corriger la cause de l’erreur
Elimina la causa dell’ errore
Corrija la causa del fallo
Ret fejlen
GB: Fejlfinding F: Défauts possible I: Uscite di allarme E: Salidas de avería DK: Fejlfinding
F
I
Fluid
Output activated if fluid level is
too low.
GB
La sortie est activée si le niveau de
liquide est bas.
L’uscita si attiva quando il livello di
liquido è troppo basso.
La salida se activa si el nivel de
líquido es demasiado bajo.
E
Udgang trækker, hvis væskestanden bliver lav.
Fault
Output activated in case of system
error. Error type can be read in
the display.
La sortie est activée lors d’une erreur de l’appareil. Le type d’erreur
est indiqué sur l’écran.
L’uscita si attiva in caso di anomalia di sistema. Il tipo di guasto
viene indicato sul display.
La salida se activa en caso de un
fallo en el aparato. El tipo de fallo
se lee en el display.
Udgang bliver aktiv ved en
fejl i apparatet. Fejltypen kan
aflæses af displayet.
Fog
When the Fog Cannon produces
fog, this output will activate.
Lorsque le générateur produit de la
fumée, cette sortie est activée.
L’uscita è attiva durante la generazione di nebbia.
Cuando el generador produce
niebla, esta salida se activa.
Når tågekanonen produ­cerer
tåge, vil denne udgang blive
aktiv.
DK
GB: Fuses F: Fusibles I: Fusibili E: Fusibles DK: Sikringer
230V AC Fuses / Fusibles / Fusibili / Fusibles / Fuses
PROTECTTM 600i
PROTECTTM 1100i
PROTECTTM 2200i
F1 (Incoming Power/High Voltage)
10 AT
10 AT
10 AT
F3
6.3 AT
8 AT
10 AT
F4
0.5 AT
0.5 AT
1 AT
20
PROTECT™ 600i/1100i/2200i
GB: External LED status indicator – a service function in arm and
disarm status.
F:
LED exterieure d’ indicateurs d’état –
fonction mise en- ou hors- service du système (+/- 12v sur DIS).
I:
Indicatore esterno di stato a LEDs,
diagnostiche di guasto.
E:
Indicador LED externo de estado encendido tanto en estado de armado como desarmado.
DK: Dioder til ekstern statusmelding - en servicefunktion i frakoblet
og tilkoblet tilstand.
Green and yellow light / Lumière verte et jaune /
Luce verde e giallo / LED Luz verde y amarilla /
Grøn og gult lys
Red light / LED rouge / Led rosso / Luz roja / Rødt lys
GB
Green LED flashes first time the Fog Cannon is connected to mains power.
Green LED lights constantly on when the Fog Cannon is heated and ready.
Yellow LED flashes for low fluid level. Check fluid. All LEDs are turned off
when Fog Cannon has arm signal from alarm panel (disable signal is removed).
One Red flash every 10 seconds (E1): Mains power failure (and no critical failure
at the same time). Three Red flashes every 10 seconds (E3): Fire alarm input activated (and no critical failure at the same time). Four Red flashes every 10 seconds
(E4): Low battery voltage (and no critical failure at the same time). Alarm installer
is required! Constant Red flashing: Serious failure(s) detected. Alarm installer is
required!
F
Led verte clignote à la première connection électrique du canon à fumée.
Led verte est allumée en permanence lorsque le canon à fumée est chaud
et est prêt à fonctionner. Led jaune clignote lorsque le niveau du liquide
est bas. Vérifiez le produit. Tous les voyants sont éteints lorsque le canon à
fumée est mis en Marche à partir du clavier d’Alarme ( le contact « DISABLE
»est enlevé: 0V).
Un flash rouge toutes les 10 secondes (E1): défaut secteur (220 V). Trois clignotements rouges toutes les 10 secondes (E3): activation de l’entrée FIRE. Quatre
clignotements rouges toutes les 10 secondes (E4): batterie basse. Clignotement
rouge constant: panne majeure: nécessite une intervention de l’installateur.
Led verde lampeggia al collegamento alla alimentazione di rete. Led verde
costantemente acceso: sistema pronto. Led giallo lampeggia: fluido basso,
controllare il livello del fluido. Tutti i Leds spenti: il nebbiogeno è settato in
ARM dal sistema d’allarme (comando DISABLE assente).
1 Flash del Led rosso ogni 10 secondi (E1): mancanza di alimentazione di rete
(senza contemporaneamente allarme critico). 3 Flashes del Led rosso ogni 10
secondi (E3): ingresso allarme incendio attivato (senza contemporaneamente
allarme critico). 4 Flashes del Led rosso ogni 10 secondi (E4): voltaggio basso
delle batterie (senza contemporaneamente allarme critico). Necessario intervento
tecnico.
Led rosso lampeggio costante: guasto grave, necessario intervento tecnico.
El Led verde parpadea al conectar por primera vez el Generador de Niebla
a la corriente alterna. El Led verde se mantiene encendido cuando el Generador de Niebla está caliente y preparado. El Led amarillo parpadea si hay
bajo nivel de fluido. Verifique dicho nivel. Todos los Leds se apagarán al
activar el Generador de Niebla desde el sistema de alarma (se retira la señal
de inhabilitación).
Un parpadeo rojo cada 10 segundos (E1): Fallo de alimentación de red (y sin fallo
crítico al mismo tiempo). Tres parpadeos en rojo cada 10 segundos (E3): Activación de la entrada de alarma de incendio (y sin fallo crítico al mismo tiempo).
Cuatro parpadeos en rojo cada 10 segundos (E4): Baja batería (y sin fallo crítico
al mismo tiempo). Se requiere la presencia del instalador. Parpadeo constante
en rojo: Se ha producido una avería importante. Se requiere la presencia del instalador.
I
E
DK
Grøn diode blinker, når der sættes strøm til tågekanonen. Grøn diode lyser konstant, når tågekanonen er varm og klar. Gul diode blinker ved lav
væskestand. Kontroller væske. Alle lysdioder slukkes, når alarmen tilkobles.
(disable-signalet fjernes).
Ét blink pr. 10 sek. (E1): Ved svigt af netspænding (og der samtidig ikke er en
mere kritisk fejl). Tre blink pr. 10 sek. (E3): Ved aktiveret brandalarmindgang (og
der samtidig ikke er en mere kritisk fejl). Fire blink pr. 10 sek. (E4): Ved lav batterispænding (og der samtidig ikke er en mere kritisk fejl). Kræver servicebesøg.
Konstant blinken: Ved alvorlige fejl, som kræver indgreb fra installatøren.
21
PROTECT™ 600i/1100i/2200i
GB: Display/fault codes
F: Afficheur/Codes d’erreur
I: Significato dei codici a display
E: Display/códigos de avería
PrO Ec 600 EU
H.
r.
d.
H.d.
B. .
A.
P.
S.
H: Heat
r: ready
d: disable
GB
Hd: Heat disable
Bt: Blocking timer
A: Arm trig
DK:
Display/fejlkoder
b.A. . bat: battery
C.
C: Charge
E.
E: Error + no
P: Primary trig
1.234567890
S: Secondary trig
1. 2 3 4 5 6 8 7 9 0
E
DK
F
I
H
Heating. The system is in the
heating phase and has not reached
operating temperature.
Chauffage. La machine est en train
de chauffer et n’a pas encore atteint
la température de fonctionnement.
Heat Il sistema è in fase di riscaldamento, la temperatura di esercizio
non è ancora stata raggiunta.
Calentamiento. La máquina está
en la fase de calentamiento y no
ha alcanzado su temperatura de
funcionamiento.
Heating. Maskinen er i
opvarmnings­fasen og har ikke nået
driftstempera­tur.
r
The system has reached normal
operating temperature and is ready
to produce fog.
La machine a atteint la température
de fonctionnement normale et peut
produire de la fumée.
ready Il sistema ha raggiunto la
temperatura necessaria ed è pronto
al funzionamento.
La máquina ha alcanzado su temperatura de funcionamiento y está
lista para la generación de niebla.
Maskinen har nået normal
driftstemperatur og kan producere
tåge.
d
”Disable” input activated and
system blocked, as the alarm is not
connected (heating has not been
disconnected).
L’entrée “Disable” est activée et la
machine est bloquée car l’alarme
est à l’arrêt (le chauffage
n’est pas éteint).
disable L’ingresso “Disable” è
attivato e il sistema bloccato, in
quanto il sistema d’allarme non è
inserito. Il riscaldamento non è stato
disattivato.
La entrada ”desactivar” está
activada y la máquina está bloqueada, ya que la alarma no está
conectada (el calentamiento no está
desconectado).
”Disable” indgang aktiveret, og
maskinen er blokeret, da alarmen
ikke er tilkoblet (varmen er ikke
koblet fra)
Hd
”Heat Disable”. ”Disable” input
activated and system blocked, as
the alarm is not connected. Heating
is also disconnected, as dipswitch 1
is in the ON position.
“Heat Disable”. L’entrée “Disable”
est activée et la machine est
bloquée car l’alarme est à l’arrêt
connectée. Le chauffage est également éteint car l’interrupteur DIP 1
est sur la position ON.
Heat disable L’ingresso “Disable”
è attivato e il sistema bloccato, in
quanto il sistema d’allarme non è inserito. Il riscaldamento è disattivato
(DIP switch 1 in posizione ON).
”Desactivar calentamiento”. La
entrada ”Desactivar” está activada
y la máquina está bloqueada ya
que la alarma no está conectada.
El calentamiento también está
desconectado ya que el conmutador
1 está en posición ON.
”Heat Disable”. ”Disable” indgang
aktiveret, og maskinen er blokeret,
da alarmen ikke er tilkoblet.
Varmen er også koblet fra, da
dipswitch 1 står i ON position.
bt
“Blocking timer active”. System
blocked from fog triggering internally
(timer-controlled). This occurs after
the fog has been triggered or in connection with system start-up after
loss of mains voltage.
“Blocking timer active”. La machine
est bloquée contre le déclenchement interne de la fumée (commandé par le temporisateur). C’est
ce qui se passe lorsque la fumée a
été émise, lorsque la machine est
lancée, ou après une perte de tension du réseau.
Blocking timer ”Timer di blocco
attivo”. Sistema bloccato internamente dal temporizzatore. Accade
dopo che la nebbia è stata attivata o
dopo il restart successivo a perdita
di alimentazione da rete.
”Temporizador de bloqueo activo”
La máquina está bloqueada contra
el disparo de la niebla (controlado
por temporizador) en relación con la
puesta en marcha de la máquina o
la pérdida de tensión de red.
“Blocking timer active”. Maskinen
er blokeret mod udløsning af tågen
internt (timer styret). Dette sker
efter, at tågen har været udløst,
eller i forbindelse med opstart af
maskinen efter tab af netspænding,
ved forkert indstillet tågetid eller
hvis lav væskestand.
A
“ARM” input activated.
L’entré “ARM” est activée.
Arm trig Ingresso ”ARM” attivato.
La entrada ”ARM” está activada.
“ARM” indgangen er aktiveret.
La entrada ”Activación primaria”
está activada.
“Primary Trig” indgangen er
aktiveret.
P
“Primary Trig” input activated.
L’entrée “Primary Trig” est activée.
Primary trig Ingresso “Attivazione
primaria” attivo.
S
“Secondary Trig” input activated.
L’entrée “Secondary Trig” est
activée.
Secondary trig Ingresso “Attivazione
secondaria” attivo.
La entrada ”Activación secundaria”
está activada.
“Secondary Trig” indgangen er
aktiveret.
A battery is (or has been) mounted.
Une batterie est (ou a été) installée.
Battery Batterie collegate.
Hay (o ha habido) una batería
montada.
Der er (eller har været) et batteri
monteret.
The battery is currently being
charged.
La batterie est en cours de chargement.
Charge Batterie in carica.
La batería se está cargando.
Der lades i øjeblikket på batteriet.
Fallo de tensión de red.
Netspænding’s svigt – auto reset
bAt
C
E1
Mains voltage failure.
Panne de tension du réseau.
Error 1 Mancanza alimentazione
di rete.
E2
Low fluid level.
Niveau liquide bas.
Livello di liquido basso.
Nivel de líquido bajo.
Lav væskestand – auto reset
E3
Fire alarm input activated.
Entrée de l’alarme incendie activée.
Input “Allarme incendio” attivo.
Entrada de alarma de incendio
activada.
Brandalarm indgang aktiveret –
auto reset
E4
Low battery voltage.
Tension de batterie basse.
Tensione batteria bassa.
Tensión de batería baja.
Batterispænding lav – auto reset
E5
Failed attempts to charge the battery for 24 hours.
Chargement de la batterie inopérant
après 24 heures.
Ricarica batteria non riuscita durante
le ultime 24 ore.
Intento inútil de cargar la batería
durante 24 horas.
Batteri forgæves forsøgt opladet
i 24 timer.
E6
Battery failed load test.
Erreur de batterie détectée par le
test de charge.
La batteria non supera il test di
carica.
La batería no pasó la prueba de
carga.
Batteriet fejlede i belastningstest.
E7
PCB temperature too high.
Température du circuit imprimé
trop élevée.
Temperatura della scheda elettronica
troppo elevata.
Temperatura del circuito
demasiado alta.
Temperaturen på printet for høj.
E8
PCB temperature too low.
Température du circuit imprimé
trop basse.
Temperatura della scheda elettronica
troppo bassa.
Temperatura del circuito
demasiado baja.
Temperaturen på printet for lav.
E9
Thermo-sensor temperature too high
(or connection lost).
Température du capteur thermique
trop élevée (ou perte de connexion).
Temperatura del sensore termico
troppo alta (o non collegato).
Temperatura del sensor térmico
demasiado alta (o pérdida de conexión).
Termoføler temperatur for høj (eller
mistet forbindelse).
E10
Thermo-sensor temperature too low
(after preliminary heating).
Température du capteur thermique
trop basse (après la première phase
de chauffe).
Temperatura del sensore termico
troppo bassa (dopo il riscaldamento
iniziale).
Temperatura del sensor térmico
demasiado baja (después del calentamiento inicial).
Termoføler-temperatur for lav (efter
indledende opvarmning).
E12
Pump timeout. The pump has
been running for too long. Lack of
fluid, etc.
Temporisation de la pompe. La
pompe a fonctionné trop longtemps.
Manque de liquide.
Temporizzazione della pompa.
La pompa ha funzionato troppo a
lungo: mancanza di liquido ecc
Tiempo de espera de la bomba por
tiempo de funcionamiento excedido,
falta de líquido, etc.
Pumpe Timeout. Pumpen har kørt
for længe. Væskemangel etc.
E13
External 12 supply shut down due
to overload.
L’alimentation 12V externe est
fermée à cause d’une surcharge.
Alimentazione esterna 12V
bloccata per carico eccessivo.
Alimentación externa 12 cerrada por
sobrecarga.
Ekstern 12 forsyning lukket ned
pga. overlast.
E14
Error in “load test circuit”.
Erreur dans le circuit du test de
charge.
Errore nel circuito di test di carica.
Fallo en el ”circuito de ensayo de
carga”.
Fejl i “load test kredsløbet”.
22
PROTECT™ 600i/1100i/2200i
5. Warnings: Must be read by users and fitters of PROTECT security fog protection
F:
I:
E:
DK:
GB
Avertissements: Doit être lu par les utilisateurs et les installateurs de générateur de brouillard.
Avvertenze: Devono essere lette dall’utilizzatore e dall’installatore del generatore di nebbia PROTECT
Advertencias: Deben ser leídas por los usuarios e instaladores de la protección por niebla Protect.
Advarsler: Skal læses af brugere og installatører af PROTECT tågesikring.
- Spilled fog fluid from dripping or other, which has gathered on the
floor underneath the machine, immediately after the system has
been activated or in connection with the handling of the fog fluid,
must be removed immediately due to the risk of slipping and falling.
- Do not swallow the fog liquid, and keep it away from children and
animals. In case of ingestion of large quantities: Contact a physician
immediately. Avoid contact with eyes. In case of contact with eyes,
rinse immediately with clean water for min. 15 minutes. If irritation
continues, contact a physician. In case of direct contact with skin
rinse thoroughly with water and soap.
- Avoid prolonged stays in fog filled premises as this can irritate the
mucous membrane in the eyes, nose and throat. The effect is temporary and only occurs in connection with prolonged stays in the
dense fog.
- Never stick your fingers or other objects behind the grille in front of
the nozzle. The nozzle may be hot and touching it may cause burns.
Do not look directly into the nozzle.
- Flammable or heat-sensitive objects must be placed at least 35 cm.
from the nozzle.
- The system must only be cleaned using a damp cloth. Do not spray
it with water.
- Air the room for 20 minutes within the first hour of fog activation to
avoid condensation.
- The installer must ensure that staff who work in the secured premises
on a daily basis are informed about the proper rules of precaution
when operating the Fog Cannon.
- If the Fog Cannon is installed in premises with public access, the staff
needs to be instructed in how to guide visitors and show them the way
out in case the Fog Cannon should fire unintentionally at a time where
people have access to the secured premises.
- The electrical connections of the Fog Cannon must only be handled
by certified electrical fitter. The system MUST be connected to earth
to meet electrical safety requirements and must only be serviced by
instructed personnel. PROTECT and our distributors worldwide provide training sessions regarding correct mounting, setting and use of
the system. The system should be fitted with max. 16A fuses.
- The device must be connected to the mains supply via a plug or via
switch which breaks all the conducting poles (both live and neutral).
- The system must be set correctly to prevent overdosing. Never install the system without supervision (connection to alarm panel and
control centre) and service/test the system once a year. Servicing/
tests must be carried out by an alarm technician.
- The system must be placed outside normal reach. The system must
not be placed e.g. near the floor where animals or children can reach
it.
- The system must not be installed in a way which blocks emergency
exits or fire escapes when fired.
- Place the system with the distance from the nozzle to the nearest
object or surface being min. 2.5 m. Secure the system properly.
- Make sure that there is sufficient ventilation space around the system
(minimum 15 cm). Do not fit the system in a closed cavity space.
- Disconnect the mains supply before removing protective covers.
Live parts are accessible inside the device, and there may be risk
of electrical chock.
- The system is produced for use in a dry indoor climate and must
therefore not be placed outdoors or in damp rooms.
- Special precautions must be taken where the Fog Cannons are installed in locations with automatic fire alarm systems and in blocks
of flats.
- Before installing the Fog Cannons the installer must ensure that this
can be done in accordance with relevant national legislation and regional regulations. The installer must inform the authorities, the control centre and security staff of the installation.
- Before service on signalling cables, the Fog Cannon and connected
equipment such as alarms, etc. the Fog Cannon must be protected
against unintentional firing. The system must be protected against
activation when the secured premises are in normal use.
- If the above instructions are not observed, PROTECT A/S shall not be
liable for any consequences resulting from such non-observance.
- Certain types of thermal paper, thermal labels and certain types of
ink used for print on plastic wrappings and plastic bags can be damaged by the fog.
- This PROTECT fog cannon is only to be installed and used in the
country, from where it is purchased. Local PROTECT dealers/installers only service machines purchased in their own countries.
F
-L
e liquide fumigène répandu par terre sous le générateur immédiatement après le déclenchement du générateur ou lors de la manipulation du liquide doit être épongé aussitôt pour éviter tout glissement
ou chute.
- Ne pas ingérer le liquide fumigène et ne pas le laisser à la portée
des enfants ni des animaux. En cas d’ingestion dans des quantités
importantes, appeler immédiatement le médecin. Eviter que le liquide fumigène ne soit en contact avec les yeux. En cas de contact
avec les yeux, rincer immédiatement avec de l’eau pure pendant au
moins un quart d’heure. Contacter le médecin si l’inconfort persiste.
En cas de contact direct avec la peau, nettoyer soigneusement avec
de l’eau et du savon.
- Eviter de rester longtemps dans les pièces remplies de fumée car la
fumée peut irriter les muqueuses des yeux, du nez et de la gorge.
L’irritation est passagère et n’apparaît qu’après une longue période
dans une fumée dense.
- Ne jamais glisser un doigt ou un objet derrière la grille du diffuseur.
Danger de brûlure car le diffuseur peut être chaud. Ne pas regarder
directement dans le diffuseur.
- Les objets inflammables ou thermosensibles doivent être placés à au
moins 35 cm du diffuseur.
- Nettoyer le générateur uniquement à l’aide d’un chiffon humide. Ne
pas asperger le générateur d’eau.
- Dans l’heure après la décharge de la fumée, il faut aérer la pièce
pendant au moins 20 minutes pour éviter la condensation.
- Il appartient à l’électricien-installateur de s’assurer que les employés qui travaillent dans les pièces protégées soient informés des
mesures appropriées à prendre en cas de décharge de fumée.
- Si la protection fumigène est installée dans des locaux avec accès
au public, les employés doivent savoir comment guider les visiteurs
et leur montrer la sortie au cas où la fumée est déclenchée de façon
non intentionnelle pendant que les personnes ont un accès normal
aux zones protégées.
- Seuls les installateurs électriques agréés sont autorisés á effectuer
les branchements électriques du générateur. Le générateur doit
obligatoirement être mis à la terre pour remplir les conditions de sécurité électrique, et les opérations d’entretien et de service doivent
être exécutées par des personnes formées. PROTECT organise des
cours de montage, d’ajustage et d’utilisation des générateurs de
fumée. La machine doit être équipée avec des fusibles de 16A au
maximum.
- La machine doit être raccordée au réseau électrique par une fiche ou
via un interrupteur qui coupe toutes les bornes conductrices (neutre
et phase).
- Il faut régler le générateur correctement pour éviter tout surdosage.
Ne jamais effectuer l’installation sans surveillance (branchement au
panneau d’alarmes et à la centrale de contrôle). Effectuer une opération de service/un essai du générateur une fois par an. Pour cela,
faire appel à un technicien d’alarme.
1/3
23
PROTECT™ 600i/1100i/2200i
- Placer le générateur hors de portée normale, p.ex. pas trop près du
plancher d’où les enfants et les animaux peuvent le toucher.
- Installer le générateur de telle manière que la fumée déchargée
n’obstrue pas les sorties de secours ni les escaliers d’incendie.
- Veiller à ce qu’il y ait suffisamment d’espace d’aération autour du
générateur (au moins 15 cm). Ne pas encastrer le générateur dans
le mur.
- Ne pas démonter les panneaux du générateur sans avoir interrompu
le courant au générateur. Dans l’appareil, des pièces sous tension
sont immédiatement accessibles, ce qui génère un risque de choc
électrique.
- Le générateur est conçu pour un climat intérieur et ne doit donc pas
être placé en plein air ni dans une pièce humide.
- Des mesures spécifiques sont à prendre, si la protection fumigène
est installée dans des locaux avec détecteurs d’incendie ou dans
des immeubles.
- Avant l’installation de la protection fumigène, il appartient à
l’installateur de s’assurer que l’installation soit conforme à la loi
nationale en vigueur et aux règlements régionaux en question.
L’installateur doit informer les autorités publiques, la centrale de
veille et le personnel de sécurité de l’installation.
- Avant d’effectuer les opérations d’entretien ou de service sur les
câbles de signal, le générateur de fumée et autres appareils branchés comme les systèmes d’alarmes etc., il faut faire en sorte que
le générateur ne soit pas déclenché de façon non intentionelle.
L’activation du générateur doit être bloquée pendant l’utilisation normale des locaux protégés.
- En cas de non-respect de ces consignes, PROTECT A/S s’exonère
de la responsabilité des suites éventuelles.
- Certains papiers ou étiquettes thermosensibles et certaines encres
utilisées pour imprimer sur les emballages et sacs en plastique peuvent être affectés par la Fumée.
- Ce Canon à fume PROTECTdoit être installé et utilisé uniquement
dans le pays de son acquisition. Seul l’installateur Local ayant acheté
l’appareil dans son pays peut en assurer l’installation et la maintenance officiellement.
I
- Il liquido caduto a terra sotto il generatore di nebbia durante
l’intervento di manutenzione o altro, deve essere immediatamente
eliminato perchè scivoloso e potrebbe provocare cadute.
- Non ingerire il liquido e tenerlo lontano dalla portata di bambini e
animali. Consultare immediatamente il medico in caso di ingestione
di quantità importanti di liquido. Evitare il contatto con gli occhi. In
caso di contatto con gli occhi, sciaquare immediatamente con acqua pulita per almeno 15 minuti. Se l’irritazione continua, consultare
il medico. In caso di contatto con la pelle risciaquare con acqua e
sapone.
- Evitare la permanenza prolungata in ambienti riempiti di nebbia:
potrebbe provocare irritamento alla mucosa di occhi, naso e gola.
L’effetto è temporaneo e può accadere solo in caso di permanenza
prolungata in ambienti con nebbia molto densa.
- Non toccare con le dita il diffusore, potrebbe essere caldo e provocare ustioni. Non guardare direttamente nell’ugello.
- Materiali infiammabili non devono trovarsi a meno di 35 cm
dall’ugello.
- L’apparato può essere pulito solamente con un panno umido. Non
spruzzare acqua sull’apparato.
- Arieggiare il locale per almeno 20 minuti entro un’ora dall’attivazione
del generatore di nebbia onde evitare processi di condensa.
- L’installatore deve preoccuparsi di informare il personale che opera
nei locali protetti riguardo le norme di precauzione da adottare.
- Se il generatore di nebbia è installato in locali pubblici, il personale
che ci lavora deve essere istruito sul modo di aiutare i visitatori ad
evacuare il locale in caso di attivazione accidentale.
- Le connessioni elettriche del dispositivo devono essere eseguite unicamente da personale abilitato. Il dispositivo deve essere collegato a
terra per ragioni di sicurezza elettrica. La manutenzione può essere
effettuata solamente da personale istruito. PROTECT organizza corsi
di formazione per installatori. Il sistema deve essere protetto con fusibili di max 16A.
- Il dispositivo deve essere collegato alla rete attraverso un interruttore
bipolare (fase e neutro).
- Il sistema deve essere impostato correttamente per evitare erogazioni
eccessive. Non installare il sistema senza supervisione (collegamento
alla centrale di allarme e al centro di vigilanza). Ispezionare il sistema
annualmente. Test e manutenzione devono essere effettuati da installatore abilitato per la sicurezza.
- Il sistema deve essere posizionato fuori dalla normale portata delle
persone. Per esempio, non deve essere installato vicino al pavimento,
alla portata di bambini o animali.
- Il sistema non deve essere installato in modo da ostacolare uscite di
emergenza e vie di fuga.
- Posizionare il sistema in modo che l’uggello si trovi ad almeno 2,5m
dall’oggetto o superficie più vicina, misurato nel senso di orientamento dell’uggello.
- Assicurarsi che ci sia sufficiente ventilazione attorno al dispositivo
(almeno 15 cm). Non posizionare il dispositivo in cavità chiuse.
- Sconnettere il dispositivo dalla rete prima di aprirlo. Pericolo di scarica elettrica.
- Il dispositivo è stato costruito per operare in ambienti chiusi e. Non
deve essere utilizzato all’esterno o in ambienti umidi.
- Precauzioni particolari devono essere prese quando il generatore di
nebbia viene installato in ambienti con sistemi di rilevazione incendio
o edifici residenziali.
- Prima di installare il generatore di nebbia bisogna assicurarsi che ciò
avvenga nel rispetto delle leggi e norme locali. L’installatore deve avvertire le autorità competenti dell’avvenuta installazione.
- Prima dell’intervento di manutenzione sul generatore o sui dispositivi
collegati (sistema di allarme), assicurarsi che lo stesso non possa essere attivato accidentalmente. Bisogna prevenire l’attivazione accidentale quando l’ambiente protetto è utilizzato regolarmente.
- Il non rispetto di queste norme di sicurezza esonera PROTECT da
ogni responsabilità.
- Alcuni tipi di carta termica, etichette termiche e alcuni tipi di inchiostro
usati per la stampa su plastica potrebbero essere danneggiati dalla
nebbia prodotta da questo generatore.
- Questo sistema nebbiogeno può essere installato e utilizzato unicamente nel Paese dove è stato acquistato. Assistenza e manutenzione
sono sempre onere di chi ha venduto il prodotto stesso.
E
- En caso de producirse goteo o derrame de líquido de niebla en el
suelo debajo de la máquina, inmediatamente después de dispararse
la máquina o durante el manejo del líquido, el líquido debe quitarse
inmediatamente por el riesgo de caídas y resbalones.
- El líquido de niebla no debe ingerirse y por eso ha de mantenerse
fuera del alcance de los niños y los animales. En caso de ingestión
de grandes cantidades: Consulte inmediatamente a un médico. Evite
que el líquido de niebla entre en contacto con los ojos. En caso de
contacto con los ojos, lave inmediatamente con agua limpia durante
al menos 15 minutos. Si persisten las molestias, contacte a un médico. En caso de contacto con la piel, lave intensamente con agua y
jabón.
- Evite permanencias prolongadas en salas llenas de niebla, ya que
esto puede causar irritación en las mucosas de los ojos, la nariz y
la garganta. El efecto es transitorio y sólo se produce en caso de
permanencias prolongadas en niebla densa.
- Nunca introduzca los dedos ni otros objetos detrás de la rejilla que
está ubicada delante de la boquilla. La boquilla puede estar caliente,
por lo que existe riesgo de quemaduras. No mire directamente dentro de la boquilla.
- No deje objetos inflamables o sensibles al calor a menos de 35 cm
de la boquilla.
- La limpieza del aparato sólo debe efectuarse con un paño húmedo.
El aparato no debe exponerse a chorros de agua.
- Dentro de la hora siguiente al accionamiento de la niebla, debe ventilarse la sala durante al menos 20 minutos para evitar la condensación.
- El instalador está obligado a informar al personal que diariamente
frecuenta los locales protegidos sobre las correctas medidas de precaución a tomar cuando se dispara la niebla.
- Si la protección por niebla se instala en un local de acceso público,
el personal debe recibir capacitación sobre cómo guiar a los visitantes para que abandonen el local en caso de que el generador de
niebla se dispare de manera accidental durante los períodos en que
el público tiene acceso al lugar protegido.
- Las conexiones eléctricas de la máquina deben ser instaladas por un
instalador eléctrico. La máquina DEBE estar conectada a tierra para
cumplir con las normas de seguridad eléctrica, y las tareas de ser-
2/3
24
vicio sólo deben ser realizadas por personal capacitado. PROTECT
organiza cursos sobre montaje, configuración y uso correctos de la
máquina. La máquina debe estar protegida con fusibles de 16A máx.
- La máquina debe conectarse a la red eléctrica mediante una clavija
de contacto o mediante un interruptor que corte todos los polos conductores (fase y neutro).
- La máquina debe ajustarse correctamente para evitar la sobredosificación. Nunca instale la máquina sin supervisión (conexión al panel
de alarma y centro de mando). Realice un servicio/ ensayo de la
máquina una vez al año (esta tarea debe ser llevada a cabo por un
técnico de alarmas).
- La máquina debe estar ubicada fuera del alcance normal, p. ej. no
debe colocarse cerca del suelo donde pueden acercarse los niños
y los animales.
- La máquina no debe instalarse de manera que bloquee las salidas de
emergencia o las escaleras de escape al dispararse.
- Coloque la máquina de modo que la distancia entre la boquilla y
el objeto o la superficie más cercanos sea de al menos 2,5 m. La
máquina debe fijarse de manera segura.
- Asegúrese de mantener un espacio de ventilación alrededor de la
máquina (mín. 15 cm). La máquina no debe empotrarse en espacios
cerrados.
- No retire las cubiertas de la máquina sin desconectar antes la co­
rriente del aparato. Las partes eléctricas están al alcance de la mano
dentro del aparato por lo que hay riesgo de choque eléctrico.
- La máquina se ha diseñado para un clima interior seco (IP20) por lo
que no debe colocarse al aire libre o en habitaciones húmedas.
- Es necesario aplicar medidas de precaución especiales si la protección por niebla se instala en lugares dotados de sistemas automáticos de alarma contra incendios o en edificios de varios pisos.
- Antes de instalar los generadores de niebla, el instalador está
o­bligado a asegurar que la instalación se realice de acuerdo con la
legislación nacional pertinente y con las regulaciones regionales. El
instalador debe dar parte a las autoridades, al centro de alarmas y al
personal de guardia.
- Antes de realizar tareas de servicio en los cables de señal, el generador de niebla y el equipo conectado (tal como alarmas, etc.), debe
asegurarse el generador de niebla contra disparos accidentales. Se
debe bloquear la máquina contra un accionamiento involuntario durante el uso normal del local protegido.
- En caso de no respetar las pautas arriba expuestas, PROTECT A/S
declina cualquier responsabilidad sobre las consecuencias de su incumplimiento.
- Ciertos tipos de papel y etiquetas por calor y ciertos tipos de tinta
usados para imprimir bolsas y envoltorios plásticos pueden verse
dañados por la niebla.
- Este generador de niebla PROTECT sólo puede ser instalado en
el país donde ha sido adquirido. Los instaladores y distribuidores
locales de PROTECT sólo realizan mantenimientos en sus propios
países.
PROTECT™ 600i/1100i/2200i
gang i sikrede lokaler, informeres om korrekte forholdsregler i forbindelse med tågens udløsning.
- Installeres tågesikring i lokaler med offentlig adgang, skal personale
instrueres i at vejlede besøgende og vise dem vej ud af lokalerne,
i det tilfælde at tågesikringen utilsigtet skulle komme til udløsning
på tidspunkter, hvor personer har normal adgang til det sikrede område.
- Maskinens elektriske forbindelser må kun tilsluttes af autoriserede elinstallatører. Maskinen SKAL jordforbindes for at leve op til kravene
for elsikkerhed, og servicering må kun foretages af instrueret personale. PROTECT afholder kurser i korrekt montering, indstilling og brug
af maskinen. Maskinen må maks. sikres med 16A sikringer.
- Maskinen skal forbindes til el-nettet via stikprop eller via afbryder, der
bryder alle ledende poler (både nul og fase).
- Maskinen skal indstilles korrekt således, at overdosering ikke
forekommer. Installer aldrig maskinen uden overvågning (tilslutning
til alarmpanel og kontrolcentral), og servicer / test maskinen en gang
om året. Dette skal foretages af en alarmtekniker.
- Maskinen skal placeres uden for normal rækkevidde. Maskinen må
f.eks. ikke placeres nær gulvet, hvor husdyr og børn kan komme til
apparatet.
- Maskinen må ikke installeres således, at den i forbindelse med udløsning danner en fælde eller blokerer nødudgange og brandtrapper.
- Placer maskinen, så afstanden fra dysen til nærmeste objekt eller
overflade er minimum 2,5 m. Maskinen skal fastgøres på forsvarlig
vis.
- Sørg for fornøden ventilationsafstand omkring maskinen (minimum
15 cm). Maskinen må ikke indbygges i aflukkede hulrum.
- Fjern ikke maskinens dæksler uden at afbryde strømmen til apparatet
først. Spændingsførende dele er umiddelbart tilgængelige inde i apparatet, og der er derfor risiko for elektrisk chok.
- Maskinen er beregnet til tørt indendørs klima (IP20) og må derfor ikke
placeres udendørs eller i fugtige rum.
- Særlige forholdsregler skal træffes, hvor tågesikring installeres i lokaler med automatiske brandalarmsystemer samt i etageejendomme.
- Før tågesikring installeres, er det installatørens ansvar at sikre sig, at
dette kan ske i overensstemmelse med relevant national lovgivning
og regionale bestemmelser. Installatøren skal informere myndighederne, vagtcentral og vagtpersonale om installationen.
- Før service på signalkabler, tågekanonen og tilsluttet udstyr, såsom
alarmanlæg og lignende, skal tågekanonen sikres imod utilsigtet affyring. Maskinen skal blokeres imod aktivering, når det sikrede lokale
er i normalt brug.
- Såfremt ovenstående retningslinier ikke overholdes, fraskriver PROTECT A/S sig ansvaret for eventuelle følger.
- Visse typer termopapir og termolabels, samt visse typer tryksværte
brugt på plast emballagen kan beskadiges af tågen.
- Denne tågekanon er kun godkendt til brug i det land, den er købt.
Lokale PROTECT-forhandlere vil kun servicere PROTECT tågekanoner købt i deres egne lande.
DK
- Spildt tågevæske i form af dryp eller lignende, der eventuelt skulle
have samlet sig på gulvet under maskinen, umiddelbart efter at
maskinen har været udløst eller i forbindelse med håndteringen af
tågevæsken, skal fjernes straks, da der ellers kan være risiko for at
glide og falde.
- Tågevæsken må ikke indtages og skal derfor holdes væk fra børn og
husdyr. Ved indtagelse af større mængder: Søg straks læge. Undgå
at få tågevæsken i øjnene. I tilfælde af stoffet i øjnene skylles straks
med rent vand i min. 15 minutter. Kontakt lægen ved fortsat ubehag.
Ved direkte kontakt med huden skylles grundigt med vand og sæbe.
- Undgå forlænget ophold i tågefyldte lokaler, da dette kan virke irriterende på slimhinder i øjne, næse og svælg. Virkningen er forbigående
og er kun forbundet med længerevarende ophold i kraftig tåge.
- Stik aldrig fingre eller andre objekter ind bag gitteret foran dysen.
Dysen kan være varm, og der er derfor risiko for forbrænding ved
berøring. Se ikke direkte ind i dysen.
- Placer ikke brandbare eller varmefølsomme objekter nærmere end
35 cm foran dysen.
- Rengøring af apparatet må kun foregå ved hjælp af en fugtig klud.
Apparatet må ikke oversprøjtes med vand.
- Inden for en time efter tågens udløsning skal der, for at undgå kondensation, sørges for fornøden udluftning i min. 20 minutter.
- Det er installatørens pligt at sikre sig, at personale, der har sin daglige
3/3
26
PROTECT™ 600i/1100i/2200i
Attestation
of conform
ity 1053
DELTA clie
nt
Protect A/S
Jegstrupve
j 30
8361 Hasse
lager
Denmark
DELTA
Product iden
certified
DELTA proj
ec
T201134
t no.
tificat
ion
Protect Fo
gC
Protect mod annon
el
Protect mod 600: 230V AC, 50-6
0
el
Protect mod 1100: 230V AC, 50 Hz, 1050 W
-60 Hz, 13
el 2200: 23
50
0V AC, 50
-60 Hz, 16 W
80 W.
Test specifi
cation
EN 501318:2009
EN 501304:2003
EN 501305:1998
EN 501311:2006
EN 501315EN 60065: 3:2005
2002
EN 610006-3:2007
Test does no
t include on
-site in
stallation,
service and
Ref. docum
maintenan
ent(s)
ce.
DELTA pr
oject no. T
201035, D
DELTA pr
ANAK-191
oject no. A
1638
530910
DELTA Pr
ojec
AK 9.11.2 t no. A506933, DANA
5 Report.
K-1910906
Revision A
Comments
and
During Apr Conclusion
il
referenced and May 2010, and O
standards.
ctober 2011
we have pe
rformed te
sts in acco
The tested
rdance to th
items have
e above list
fulfilled al
l the requir
ed and
em
en
Conclusion
ts without
remarks.
Protect mod
el
standard ac 600, Protect model
11
cording to
test specific 00, and Protect mod
el 2200 Pro
ation.
tect Fog C
annon com
ply with E
uropean
Date
Hørsholm,
31
DELTA - Ve
nlighedsvej
4 - 2970 Hø
rsholm - De
Assessor
October 20
11
nmark - Tel.
+45 72 19 40
00 - Fax +4
5 72 19 40
01 - www.m
Susanne O
tto, Consult
an
t
adebydelta.co
m
20 ass -sh ee
t-j
DELTA confirms that we
comply with the EU standard for fog security
DELTA, a highly recognised and DANAK
accredited laboratory, has tested and certified
PROTECT’s products in accordance with the
new EU standard EN 50131-8.
The conclusion of the comprehensive EMC,
environmental and functional tests is that
PROTECT’s product series, models 600i, 1100i
and 2200i, complies with the EU standard.
GB
PROTECT A/S is the world’s largest supplier and the only producer of Fog Cannons in Scandinavia.
PROTECT is represented worldwide in 40 countries.
F
PROTECT A/S est le plus grand fabriquant mondial et l’unique fabriquant en Scandinavie de Canon à
fumée. PROTECT est représentée dans le monde dans plus de 40 pays.
I
PROTECT A/S è il maggior produttore di generatori di nebbia al mondo e l’unico produttore in Scandinavia. E’presente in 40 paesi.
E
PROTECT A/S es el mayor productor mundial de cañones de niebla y el único en Escandinavia.
PROTECT se halla representada en más de 40 países.
DK
PROTECT A/S er Skandinaviens eneste og verdens største producent af tågekanoner. PROTECT er
repræsenteret i 40 lande og i Danmark af over 330 professionelle alarminstallatører.
PROTECT A/S • Jegstrupvej 30 • 8361 Hasselager • Denmark • CVR 2568 7272
Tel. +45 8672 1881 • Fax: +45 8672 1882
[email protected] • www.ProtectGlobal.com