Download Propane Floor Burnisher with Dust Control

Transcript
ENGLISH
EN
8 Hour Time Weighted Average (OSHA Method)
1.5 % 750,000cf
Hours Operation
1
2
3
4
TWA (OSHA Method)
0 change/hr
5
14 27 46
1/2 change/hr
4
9
16 24
1 change/hr
3
7
11 16
2 change/hr
2
4
7
9
5
69
33
20
11
6
96
42
25
13
7
8
128 164
50 59
29 34
16 18
Based on the CO production rates shown above the TWA would not be exceeded in a
100 x 750 x 10 foot (empty) space after 8 hours with 2 air changes per hour. (Assumes no additional CO
exposure during 8 hour time period)
Maintenance of Equipment
Warning: The proper maintenance of equipment is vital to safe operation. LPG engines are dependent on
engine tune up, and air filter replacement. CO concentration (production) skyrockets when the air to fuel ratio becomes
fuel rich. Follow the recommended Maintenance Schedule for the engine found in the Engine Operator/Owner Manual as
well as the Maintenance And Adjustments schedule found in the Propane Floor Equipment Operator’s Manual that were
supplied with the equipment. Additional manuals may be obtained by contacting at 1-800-545-3454 or write to Customer
Service, 2100 Hwy. 265, Springdale AR 72764.
CO Safety Equipment Available
• Envirogard automated fuel to air ratio monitoring and regulation providing an optimum combustion
• Three-way type catalytic converter to scrub CO, Hydro Carbons (HC), and Nitrous Oxide (NOx) from the engine
exhaust providing the lowest possible emissions
• High cubic feet per minute (CFM) fans (forced air mixing)
• Digital combustion analyzers for tail pipe emissions monitoring
SPECIFICATIONS:
Model
Part Number
Pad Size
Engine
Catalytic Muffler
Carb Gard
Clutch
Pad Speed
Propane Tank
Auto Fuel Shutoff
Low Oil Shutdown
Hour Meter
Sound Level
Productivity Rate
Agency Approvals
CARB Certified
(California Air Resource Board)
Weight
Dimensions:
Length
Widith
Height
Warranty
Page
-10-
Dust Control
2117BCATCL
2717BCATCL
08992B
08993B
21" (53 cm)
27" (68 cm)
17 hp Twin-V Kawasaki
Yes
Yes
Centrifugal
2100 RPM
1500 RPM
20 lb. (9.1 kg) Capacity, 80% Safety fill
Yes
Yes
Yes
87 - 89 dB(A)
33,000 ft2/hr (3,066 m2/hr)
25,000 ft2/hr (2,322 m2/hr)
EPA plus UL Approved Propane Components
Yes
276 lbs.
298 lbs.
66" (167.4 cm)
69" (175.3 cm)
23.5" (59.7 cm)
29.5" (74.9 cm)
43" (109.2 cm)
43" (109.2 cm)
2 Year Parts & Labor
PBU Operator's Manual (EN) - DC Propane Burnisher