ENGLISH EN 8 Hour Time Weighted Average (OSHA Method) 1.5 % 750,000cf Hours Operation 1 2 3 4 TWA (OSHA Method) 0 change/hr 5 14 27 46 1/2 change/hr 4 9 16 24 1 change/hr 3 7 11 16 2 change/hr 2 4 7 9 5 69 33 20 11 6 96 42 25 13 7 8 128 164 50 59 29 34 16 18 Based on the CO production rates shown above the TWA would not be exceeded in a 100 x 750 x 10 foot (empty) space after 8 hours with 2 air changes per hour. (Assumes no additional CO exposure during 8 hour time period) Maintenance of Equipment Warning: The proper maintenance of equipment is vital to safe operation. LPG engines are dependent on engine tune up, and air filter replacement. CO concentration (production) skyrockets when the air to fuel ratio becomes fuel rich. Follow the recommended Maintenance Schedule for the engine found in the Engine Operator/Owner Manual as well as the Maintenance And Adjustments schedule found in the Propane Floor Equipment Operator’s Manual that were supplied with the equipment. Additional manuals may be obtained by contacting at 1-800-545-3454 or write to Customer Service, 2100 Hwy. 265, Springdale AR 72764. CO Safety Equipment Available • Envirogard automated fuel to air ratio monitoring and regulation providing an optimum combustion • Three-way type catalytic converter to scrub CO, Hydro Carbons (HC), and Nitrous Oxide (NOx) from the engine exhaust providing the lowest possible emissions • High cubic feet per minute (CFM) fans (forced air mixing) • Digital combustion analyzers for tail pipe emissions monitoring SPECIFICATIONS: Model Part Number Pad Size Engine Catalytic Muffler Carb Gard Clutch Pad Speed Propane Tank Auto Fuel Shutoff Low Oil Shutdown Hour Meter Sound Level Productivity Rate Agency Approvals CARB Certified (California Air Resource Board) Weight Dimensions: Length Widith Height Warranty Page -10- Dust Control 2117BCATCL 2717BCATCL 08992B 08993B 21" (53 cm) 27" (68 cm) 17 hp Twin-V Kawasaki Yes Yes Centrifugal 2100 RPM 1500 RPM 20 lb. (9.1 kg) Capacity, 80% Safety fill Yes Yes Yes 87 - 89 dB(A) 33,000 ft2/hr (3,066 m2/hr) 25,000 ft2/hr (2,322 m2/hr) EPA plus UL Approved Propane Components Yes 276 lbs. 298 lbs. 66" (167.4 cm) 69" (175.3 cm) 23.5" (59.7 cm) 29.5" (74.9 cm) 43" (109.2 cm) 43" (109.2 cm) 2 Year Parts & Labor PBU Operator's Manual (EN) - DC Propane Burnisher