Download GRAM Compact 610 / BAKER 610
Transcript
Temperature alarm Temperature alarm – display. The controller is equipped with a temperature alarm, that monitors the cabinet temperature. The temperature value that activates the alarm, can be set by the user. If the temperature exceeds the set value, the display starts flashing according to the set time delay. To reset the alarm, turn the cabinet on and off. Setting the alarm value (setting range -35°C to +25°C – default +25°C): • Push P + 1 for more than 3 seconds. • Push + until the display shows dPL. • Push • Use the + or keys to set the value. • Push the P to view the alarm value. P key to confirm the new value. Press twice to exit the menu. Setting the time delay (setting range 0 to 120 min. – default 60 min.): Proceed as above, except the parameter for time delay is dPt. Potential free alarm relay Connector no. 19 on the power PCB is for connecting a remote alarm. A relay closes the circuit, if the temperature has been too high or too low according to the set time delay. Setting the upper alarm value (setting range -35°C to +25°C): • Push P + 1 for more than 3 seconds. • Push + until the display shows HAr. • Push • Use the + or keys to set the value. • Push the P to view the alarm value. P key to confirm the new value. Press twice to exit the menu. Setting the lower alarm value (setting range -35°C to +25°C): Proceed as above, except the parameter for lower alarm value is LAr. Setting the time delay (setting range 0 to 120 min. – default 60 min.): Proceed as above, except the parameters for upper and lower alarm time delay are HAt and LAt respectively. 76-504-1245 Gram-webshop.nl 21 Gram-webshop.nl