TROUBLESHOOTING TROUBLE POSSIBLE CAUSE REMEDY AND CONTROLS Irregular advancement of wire - incorrect wire guide pressure. check if wire guide prevents wire from rolling and adjust pressure accordingly. - wire guides are not aligned with roller track. check that wire is not bending and realign. - feed rollers or wire guide inappropriate for wire. check and if necessary change. - wire guide obstructed. remove wire guide, blow out with compressed air or soak in petrol bath. Otherwise change. - coil turns overlapping. check and if necessary change the coil. - oxidated or bad quality wire. cut oxidated turns or change coil. - excessive coil brake. adjust brake. - coil turns falling under reel. adjust reel brake. Porous weld - gas hoses not correctly connected. check. - gas cylinder empty; gas valve closed. check gas flow is regular by opening valve and disconnecting hose. - electrovalve and contactor not working. change control module and if problem reappears check connections by consulting electrical diagram provided. - electrovalve not working, contactor working. check if voltage is present at the ends of the electrovalve: if so change electrovalve - defective gas regulator. check. - gas diffusor holes obstructed. remove diffusor and clean holes. To avoid further obstructions spray the diffusor with silicon-free spray. - air current in welding area. protect arc area with adequate screens. - gas leaking hoses. check for incorrect fastening of clamps and gas. If necessary tighten. - contact pipe withdrawn too far. check - dirty workpiece. check that pieces are not noist, dirty or rusty. - bad quality of gas or wire. change wire coil or gas cylinder. Remember that gas must be dry and not humid. No wire advancement - defective torch push button. check and change. - thermal switch interruption due to overload. wait several minutes for the machine to cool. - defective fuse on auxiliary transformer. check and change. - defective feeder motor. check and change. - faulty electronic systems for speed control. check and change module. - spot timer "on". switch "off". No welding current with normal wire feed - faulty ”allow welding” relay. - - check the voltage over the ends of the reel; if it is 24v replace the relay. adjustment switch check the secondary voltage for each position of the switches. faulty rectifier. take the rectifier off the secondary and make sure each thyristor is “blocked” for both direct and reverse polarisation; if not, replace the rectifier. faulty thyristor electronic control board failure of one or more start signals from thyristor gates: replace the control board earth cable positioned badly. connect the earth clamp directly to the piece being welded; make sure the cable is intact and tightly connected to the earth clamp. Minimum and maximum wire speed incorrect - wrong regulation of speed control system adjust trimmers on control module to correct speed. ______________(D)______________ BEDIENUNGSANLEITUNG ACHTUNG: VOR GEBRAUCH DER MASCHINE LESEN SIE SORGFÄLTIG DIE BETRIEBSANLEITUNG SICHERHEITSNORMEN - - - 12 - Vermeiden Sie direkten kontakten mit dem Schweißstromkreis. Die Leerspannung des Generators kann unter Umständen gefährlich sein. Bevor Sie Installationen oder Reparatur-und Prümassnahmen ausführen, schalten Sie unbedingt das Gerät von der Stromquelle ab. Vor Ersatz der Verschleißteile des Schweißbrenners ist der Netzstecker zu ziehen. Die Schweißmaschine darf ausschließlich an ein Versorgungsnetz mit geerdetem Nulleiter angeschlossen werden. Die Schweißmaschine darf ausschließlich an ein Versorgungsnetz mit geerdetem Nulleiter angeschlossen werden. Vergewissern Sie sich, dass die Steckdose korrekt geerdet ist. Verwenden Sie nie das Gerät in feuchter oder nasser Umgebung oder bei Regen. Verwenden Sie keine Leitungen mit schlechten Isolierung oder verstärkten Verbindungen. Schweißen Sie nicht auf Kontainern, Behältern oder Rohrleitungen, die aus entflammbaren Materialen, Gasen oder Brennmaterialien besiehen.