Transcript
6.2. General precautions concerning water circuit NOTICE Before continuing the installation of the unit, check the following points: In most applications this miminum water volume will have a satisfying result. ■ The maximum water pressure is 4 bar. ■ The maximum water temperature is 80°C. In critical processes or in rooms with a high heat load though, extra water volume might be required. ■ Provide adequate safeguards in the water circuit to be sure that the water pressure will never exceed the maximum allowable working pressure (4 bar). NOTICE ■ Shut-off valves from flexible hoses delivered with the unit should be installed so that normal servicing can be accomplished without draining the system. ■ Drain taps must be provided at all low points of the system to permit complete drainage of the circuit during maintenance or service to the unit. A drain valve is provided in the unit to drain the water from the unit water system. ■ Be sure to provide a proper drain for the pressure relief valve to avoid any water coming into contact with electrical parts. ■ When circulation in each space heating/radiator loop is controlled by remotely controlled valves, it is important that this minimum water volume is kept even if all the valves are closed. Example (See "6.3. Application examples" on page 9.) A B 12 11 2 3 1 C1 11 4 Air vents must be provided at all high points of the system. The vents shall be located at points which are easily accessible for servicing. An automatic air purge is provided inside the indoor unit. Check that this air purge valve is not tightened too much so that automatic release of air in the water circuit remains possible. ■ Take care that the components installed in the field piping can withstand the water pressure and temperature. ■ Always use materials which are compatible with the water used in the system and with the materials used on the unit. ■ Select piping diameter in relation to required water flow and available ESP of the pump. When designing the hydraulic system always consider the available static pressure of the indoor unit. ESP [kPa] 120 110 100 90 80 70 60 50 40 30 20 10 0 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Flow [l/min] ESP (kPa) External static pressure (kPa) flow (l/min) Flow (l/min) 6 78 9 10 M3 T3 M2 T2 M1 12 5 T1 1 2 3 4 5 6 7 8 9 10 11 12 C1 M1...M3 Outdoor unit Indoor unit Refrigerant heat exchanger Water heat exchanger Compressor Pump Shut-off valve Collector (field supply) By-pass valve (field supply) Radiator (field supply) Electronic expansion valve Indoor unit refrigerant stop valve Remote controller Individual motorized valve to control loop radiators (field supply) T1...T3 Individual room thermostat (field supply) A Installation space B Living room Without 3-way valve Including 3-way valve Maximum external static pressure if ΔT=10°C (heating) Maximum external static pressure if ΔT=5°C (heating) INFORMATION ■ The ESP curve is the maximum ESP curve. The pump of the indoor module is inverter controlled and controls to have a fixed ΔT between return and leaving water temperature. ■ In case of installing a domestic hot water tank there is an additional pressure drop over the 3-way valve (delivered as accessory with the tank). Check that the total water volume in the installation, excluding the internal water volume of the unit, is 20 l minimum. Installation manual 8 HXHD125A7V1B VRVIII system indoor unit 4PW62584-1A – 11.2010