Download USER MANUAL
Transcript
BOXER / MARLIN / FALCON / POLAR SERIES USER MANUAL Description of the program cycle for digital sensor control 1. Select the program number with the PROG key and the small display. If the selected program is programmed with the active gas flush function then a dot appears in the lower right hand corner of the small display. If the selected program is programmed with the active VACUUM PLUS function then a dot appears in the lower right hand corner of the large display. 2. Close the lid. 3. Vacuum function The machine starts to vacuum the chamber. The light in front of [VACUUM] is burning. Large Display: incrementing percentage vacuum until the percentage set (max.. 99%). Vacuum meter starts increasing counter clock wise. 4. Vacuum Plus function The machine continues vacuuming the chamber after 99% value is reached. The light in front of [VACUUM] is burning. Large Display: decrementing time per second starting at the time set (max. 99 sec.) and a dot in the lower right hand corner. The vacuum meter will very slowly increment counter clock wise (hardly noticeable). Remark: can only be installed with a vacuum function whereby the value is set to the maximum of 99%. (if installed) 5. Gas flush Function (if installed) 6 Gas flush Plus Function (if activated) Once the vacuum function has completed, the gas flush function starts to flush gas into the vacuum chamber. The light in front of [GAS] is burning. Large Display: decrementing percentage vacuum until the set percentage (min. 30%). Vacuum meter starts decreasing clock wise. Once the normal gas flush phase is finished, it is possible to add time for additional gas flushing. With this extra gas can be inserted while the sealing system is closing. 7. Seal function When the vacuum function or gas flush function (if installed) ends, the seal function starts to seal the vacuum bag(s). The light in front of [SEAL] is burning. Large Display: decrementing time per second starting at the time set (max. 6.0 sec.). The reading on the vacuum meter stays the same. 8. Soft-air ventilation function After ending the seal function the soft air function starts to slowly ventilate the vacuum chamber. The light in front of [SOFT AIR] is burning. Large Display: decrementing time per second starting at the time set (max. 99 sec.). Vacuum meter starts slowly decreasing clock wise. (if installed) 9. Ventilation function After ending the seal function or the soft air function (if installed) the ventilation function starts ventilating the chamber to 1 atmosphere/ATO and the lid opens. All lights are off in front of the functions. Large Display: lines going up and down until the lid is open. The vacuum meter runs back to the right to zero and the lid opens automatically. 10. The product is packed and ready to remove. Version 11.10 DIG.EN 17