Download technical installation manual vers. 13

Transcript
ingenium
www.ingeniumsl.com
fire and gas sensors
· B-DTV
· B-DTV
BUSing® fire/smoke sensors Adapter
Installation
Allows adapting conventional analog sensors (loop type).
Cable
4x0.5mm
• Integrated circuit
+12 A B Ref.
+ -
Consumes
• 2 wires connection
· B-DTV
+12V
A
B
Ref.
• Mounting on the rear of the sensor
ingenium
www.ingeniumsl.com
• Size: Ø 30x15mm
Description
This device allows the connection of a conventional fire or gas loop type (2 wires) sensor to the BUSing® system.
Ð
Connection to sensor
2 wires loop type
M‡x. distance: 30m
With this solution, the sensor becomes into another home automation device, connectable to BUS and completely programmable and configurable from the Development System (SIDE).
Configuration using Development System (SIDE)
• 2 programmable scenes for activation and deactivation of the sensor.
• Up to 60 programmable BUS events for each scene.
+
Technical Characteristics
Device
Reference
Voltage
Supply
Current
Consumption
Number of
connectable sensors
Max. Recommended
Distance
B-DTV
9–16V DC (BUS)
25mA (BUS)
3
30m*
Connection example to DH/DTV
Fire or gas sensor
* maximum recommended distance between sensor and adapter
Cable
4x0.5mm
Consumes
+12V
A
B
Ref.
á DH/DTV
4
3
2
Connection of additional DH/DTV sensors
Up to 3 sensors can be connected directly
to a B-DTV.
Ð
Ð
+
3
3
1
2
+
3
4
Ð
+
4
2
1
4
2
1
1