December 10, 2010 A USER’S GUIDE TO ENERGYPLAN not, or never needed to, charge and discharge at the same time. To simulate this scenario in EnergyPLAN, select NO for “Allow for simultaneous operation of turbine and pump”. However, if energy storage devices are designed especially to integrate fluctuating renewable energy, there may be additional benefits when using PHES that can charge and discharge at the same time. This can be achieved in a single PHES facility by installing two penstocks, as displayed in Figure 20, or also by installing multiple single penstock system PHES facilities on the same energy system i.e. one can charge while the other is discharging at the same time. By using a double penstock system, the PHES introduces more flexibility onto the energy system and hence it can aid the integration of more renewable energy. As a result, this operating strategy is also possible in EnergyPLAN by selecting YES when asked “Allow for simultaneous operation of turbine and pump”. Upper Reservoir
Electricity Out During Discharging Upper Reservoir
Electricity Out During Discharging Generator
Turbine Pump Turbine
Motor/Generator Double Electricity In Single Pump Lower Reservoir
Lower Reservoir Electricity In (A) (B)
Figure 20: One PHES facility with (A) a single penstock system and (B) a double penstock system. So how do these operating strategies affect the hourly operation of the system in EnergyPLAN? To illustrate this, an example is presented in Table 4‐1 using the parameters defined in Table 4‐2. As seen in Table 4‐1, the primary advantage of a double penstock PHES facility relates to grid stabilisation: to see how the grid stabilisation percentage is calculated, see section 8.3 of the EnergyPLAN user manual. As the pump and turbine can operate together, a double penstock system can store excess wind production using the pump, while also producing grid stabilising power using the turbine. In contrast, the single penstock system has to prioritise one of these as the pump and turbine cannot operate together. From Table 4‐1 it is clear that the single penstock system prioritises the pump and therefore, the excess electricity is sent to the PHES while the power plants (PP) must now provide the grid stabilising power. As a result, a system with single penstock PHES facility typically requires more fuel (i.e. more PP production) than a system with a double penstock PHES. Also, as a double penstock can charge and discharge at the same time, the storage capacity does not fill up as quickly as a single penstock system. Therefore, double penstock system can achieve higher fluctuating renewable energy penetrations at lower storage capacities than a single penstock system. 36 Areas of Difficulty | University of Limerick