Transcript
Operating Instructions 03/2009 Screwless Wall Socket 1 2 Remove 90 mm of the outer cable sheath and feed it through the grommet into the enclosure. Then strip 8-10 mm of insulation from the wires. While pressing the release lever, bend one wire and insert into its terminal. Repeat this process until all wires have been placed in their designated terminal. 3 Solid conductors, cross section 1,5 to 4 mm2. Strip wire and you’re done. Flexible conductor, cross section 1,5 to 2,5 mm2, with wire end ferrule, crimped in a gastight manner. Flexible conductor, cross section 1,5 to 4 mm2, ultrasonically welded. Simply press the release lever to remove wire from its terminal. Walther-Werke · Ferdinand Walther GmbH P.O. Box 11 80 · 67298 Eisenberg/Pfalz Phone + (49) 63 51 / 475-0 Fax + (49) 63 51 / 475-227 Internet: www.walther-werke.de E-mail: [email protected] Latest version (update): www.walther-werke.de Use ruler to determine length of cable sheat / wire insulation to be removed (90 mm / 10 mm): 90 80 70 60 50 40 30 20 10 (For a true to scale printout choose „no page adjustment” in the print menu). 0