Download GIPDC/B User Guide - Aura Light Sverige
Transcript
GIPDC/B User Guide • Single gang PIR switch • Replaces a standard light switch or dimmer • Turns off automatically • Turns on automatically • Security mode • Switches all lighting, heating and ventilation loads up to 10A installation This product should be installed in accordance with the current IEE wiring regulations. If in doubt consult a qualified electrician. Compatible with all BS4662 dimensions back boxes. Remove top and bottom lugs if fitted. Use the extender if there is less than 25mm free space. REMEMBER – put the wires through the extender before connecting. 25mm Do not overtighten Location It is important to locate the detector so that any occupants fall within the detection zone shown on the diagram. Do not block the sensor with a door or other object. Do not install above a radiator or other heat source. Avoid direct sunlight entering the sensor. 2 ✘ ✔ 5M M 4.5 Detection zone wiring 1 way switching If the lights are controlled from one location only, wire as in the diagram. May have red May have sleeve red or or brown brown sleeve Com L1 Neutral Black or Blue Live Red or Brown Earth Yellow Green Strapper Yellow or Grey 2 way switching If more than one detector is required to switch the lighting (e.g. at the top and bottom of a staircase) they can be wired in parallel, as in the diagram. 3 controls and basic operation Remove front cover Use a flathead screwdriver or similar to gently prise off the cover and replace with new one by snapping on to switch. time setting daylight setting TOP off PIR lens 1 2 battery indicator ON on battery toggle switches Short press – lights on Press for more than 5 seconds to activate (see Activate section). Short press – lights off The lights will turn off whilst the area is occupied. The unit will reset to automatic operation after a period of time. Press for more than 5 seconds to de-activate (see Activate section). 4 Remove top and bottom lugs if fitted setup and suggested settings GIPDT TimeGIPDC setting 1min GIPDT – 30min rt Guide The lights will turn off after the set time Quick Start Guide period. When movement is detected, the time period automatically restarts. Clockwise = longer time period. Li Remove top su Lamps and bottom lugs if fitted May have red or brown sleeve Toggle switch settings Com 2 L Manual on (use on button): Do not Auto off (whenDo nobody not in the overtighten room, after time period). overtighten Auto on (when somebody Daylight setting This product should be installed enters room): Use this setting to adjust the point atin accordance with the current This should be in installed Auto product off (when nobody the room, after time period). accordance with the current which daylight brightness automatically IEE wiring regulations. in Shallow back bo IEE wiring regulations. turns lights on. Clockwise = turn on If with in doubt consult a qualified ics.co.uk Different wiring Security activated. If in doubtmode consult a qualified electrician. brighter daylight. www.cpelectronics.co.uk See ‘Security Mode’ section 2 way wiring? electrician. (pg 6). Auto on mode – in this mode lights Refer to main d remain off if there is enough natural daylight. Security mode deactivated. ttings CORRIDOR suggested settings CORRIDOR suggested settings BEDROOM ARE suggested setting meone enters the corridor to on—turns Corridoron when someone enters the corridor Bedroom body in the room for 20 minutes •forManual on—turns onsettings when top button pressed The above turn light/s on when The above turn light/s on when to off—turns off settings when nobody in the room 20 minutes ere is someone little or noenters naturalthe light • Manual on—turns when top bu corridor, turn light/s the topoffbutton pressed androom turnonlight/s • Autolight off—turns when is nobody in the for 10 minute x—only turns on when there is little or no natural off when no movement is sensed for 20 off when no•movement is sensed 10 nobody Auto off—turns off for when minutes. Only turn light/s on if there is minutes. little or no daylight. 5 activate • Before using, the unit needs to be activated • Press and hold the top button for more than 5 seconds. The red LED will flash to indicate that it has activated and the unit will now operate • If the unit is going to be out of use for prolonged periods (more than 6 months) it should be deactivated by repeating the procedure above with the bottom button. This will help to prolong battery life. security mode • Security mode can be turned on and off using the switches as shown in the ‘setup’ section • When activated, security mode is used to switch on lighting when it gets dark, giving the impression a house is occupied • When the unit senses that it is dark outside, the lights will automatically switch on for a period of 2 hours then switch off. batteries • The internal battery should last in excess of 3 years, dependent on usage • When it needs replacing, a red LED will flash on the front of the unit • Follow the steps opposite to replace the battery • Use only good quality, 9V alkaline batteries type PP3 • Once the battery has been changed activate the unit as described in the ‘activate’ section. 6 battery replacement 1.Remove front cover 4.Replace battery 2.Remove switch cover 3.Lever out battery 5. Push into holder 6. Replace switch cover 7. Replace front cover 8. Activate 7 troubleshooting Lights turn off even though room is occupied • Check location of sensor – see detection diagram • Increase timing, typically 15 minutes for a living area. Lights never turn off • The lights will only turn off after no movement is detected for the time period. Is the time period set too long? ratings EMS 534520 Voltage 230VAC +/- 10% Frequency 50Hz Temperature 0ºC to 35ºC Power 10A Compliance BS EN60669-2-1 & BS EN55015 EU registered design no. 000638069-0003, 000638069-0004 FM 45789 CP Electronics Brent Crescent London NW10 7XR T: + 44 (0)333 900 0671 F: + 44 (0)333 900 0674 www.cpelectronics.co.uk [email protected] 8 #WD411 issue 1