Download uk - Wood Burning Stoves

Transcript
WESTFIRE · WF21
WF21
DK: INSTALLATIONS- OG BRUGSVEJLEDNING
UK: INSTALLATION MANUAL AND OPERATING INSTRUCTIONS
D: INSTALLATIONS- UND GEBRAUCHSANWEISUNG
FR: NOTICE D’INSTALLATION ET D’UTILISATION
1
dansk ingeniørkunst
UK
WESTFIRE · WF21
UK: INSTALLATION MANUAL AND OPERATING INSTRUCTIONS – WESTFIRE WF21
This manual refers to the stove type listed below, which has been tested in accordance with EN 13240.
Congratulations on your purchase of a new wood burning stove from Westfire ApS. Please read this manual carefully in order to ensure that you get maximum enjoyment from your new stove and to prevent any problems.
Please note that “all local regulations, including those referring to national and European Standards, need to be
complied with when installing this appliance”.
For further information on installing and using fireplaces and wood burning stoves, please see the relevant
brochure on building regulations that applies to the country in which WF 21 has been approved, as well as the
relevant brochure on the correct use of wood burning stoves available from your local stove supplier or your
chimney sweep.
INSTALLATION GUIDELINES
You must comply with all applicable national and local building regulations when installing your wood burning
stove. Please see the applicable regulations for full details. The regulations state that flammable floors beneath
closed hearths must be covered by a fire-proof material that extends a minimum of 30 cm in front of the stove
opening and a minimum of 15 cm on either side. The fire-proof material may be e.g. a steel plate, a glass plate,
tiles or artificial slate.
The floor on which the wood burning stove is to be installed must be sufficiently strong to carry the weight of the stove.
The minimum distances to flammable materials are specified on the EN 13240 plaque on the back of the stove.
WF 21
Rear (cm)
Sides (cm)
Furniture in front (cm)
17,5 cm
30 cm
80 cm
There are no rules regarding the minimum distance to non-flammable walls, but we recommend leaving a gap of
at least 10 cm behind the stove to make cleaning easier.
Combustion requires air, and fresh air must therefore be available in the room in which the stove is installed. Air
inlets must be positioned in such a way that they cannot be blocked. An air inlet may be a vent (the vent must be
open and the capacity of the vent sufficient when the stove is lit) or a fresh air system linked to the stove.
All wood burning stoves from Westfire are fitted with heat deflection baffles, which ensure the maximum efficiency
and the clean burn of the stove. These baffles should not be removed.
CHIMNEY CONNECTION
The chimney to which the stove is connected must have a diameter of at least 15 cm, which corresponds to an
area of 175 cm2.
The chimney must be sufficiently long to provide a good chimney draft, and to ensure that the smoke from the
stove will not cause a nuisance. The chimney must be fitted with an easily accessible cleaning hatch.
WF 21 has been approved in accordance with EN 13240. The nominal heat output of this stove is 5 kW.
WF 21 has a test weight of 81 kg.
Minimum draft: The stove has been tested with a draft of 12 Pa. Max. draft 25 Pa.
Flue gas flow 6.3 g/sec.
Flue gas temperature 248°C.
WF 21 is fitted with both a top and rear outlet.
The chimney may be equipped with a regulation damper in the flue pipe to allow the draft to be regulated on
windy days. The damper must not be able to close fully, and must have a clearance of at least 20 cm2 of the total
clear opening of the pipe.
6
UK
WESTFIRE · WF21
Other types of dampers may also be used, such as allowing air to enter the chimney by bypassing the
stove.
More than 1 appliance on a flue system is not allowed in the UK under any circumstance.
Operating instructions
The heat-resistant paint on the stove will harden the first time you light up the appliance. This process produces a
good deal of smoke and odour, and the room should therefore be well ventilated.
The stove door should be kept open during the first couple of firings and only closed once the stove has cooled
down to prevent the packing cord around the door from sticking and coming away from the door. Once the
heat-resistant paint has hardened, the stove door must be kept closed except when lighting the stove, adding
firewood or removing ash in order to prevent flue gas from escaping.
Firelighters should ideally used when lighting the stove. (Never use mentholated spirit, petrol or other flammable
liquids)
To light the stove
1.Place a few smaller pieces of dry wood (kindling) in the stove on top of the non toxic firelighters.
2.Fully pull open the air slider(secondary air)
3.Light the firelighters and push the door closed until it is 1-2cm open. (do not lock the door shut)
4.Once the fire has caught, add two pieces of wood measuring approx 20cm with a combined weight of approx 1.2kg and again push the door closed until it is 1-2cm open. (do not lock the door shut)
5.After approximately 5 minutes when the fire is burning brightly shut the door. (leave air slider fully open)
6.After approximately another 7 minutes close the air slider by 10% (90% open)
At nominal heat output, expect to refuel your stove approximately once an hour.
WF 21 is designed for intermittent combustion (wood must be added often and the stove is not designed for
24-hour use).
WF 21 is equipped with a control valve for secondary air designed to ensure a plentiful supply of oxygen during firing.
When lit, the stove will get very hot and due care must therefore be exercised. Please use a glove when operating levers and dampers.
In the event of a chimney fire: Close the air damper and the stove door, and call 999 or your local fire department.
BASIC POSITIONS OF DAMPERS DURING OPERATION
Secondary air
WF 21
90 % open
You will need to become familiar with your stove in order to be able to regulate the secondary air intake correctly,
as factors such as the quality and height of your chimney, the quality of your fuel and the external conditions
play a large role. It is easy to see whether the stove is functioning correctly, however. Incomplete combustion
may lead to a build-up of hard, shiny soot on the inside of your stove. This is prevented by the introduction of
additional secondary air.
It is important to check the draft conditions before lighting your stove. This may be done, for instance, by crumpling a piece of newspaper, placing it in the combustion chamber and lighting it. The draft conditions are good if
the smoke is drawn away through the chimney.
FUEL
Never use toxic wood such as chipboard, impregnated or painted wood. Always use dry firewood. The dryness of the firewood plays an important role since the use of wet wood results in poor fuel economy and may cause tarry soot to form.
7
UK
WESTFIRE · WF21
Newly cut wood contains 60–70% water, making it totally unsuitable for use as firewood.
Newly cut wood should be stacked and air dried under cover for two years before being used as firewood.
MAINTENANCE
Ash must be removed from the stove at regular intervals.
The stove must be completely cold before being cleaned. The outside should be cleaned using a dry cloth. The
inside of the stove should be cleaned once a year. To clean the inside, remove all ash, soot and tar residue from
the combustion chamber. The smoke plate should be removed as dirt and soot will collect behind it. The packing
cord in the door will wear over time and should therefore be checked.
The stove, the flue pipe connection and the chimney should be checked regularly by a qualified engineer. The
chimney should also be checked for blockages before relighting the stove if it has not been used for an extended
period of time.
The lacquer may wear thin in exposed places due to overheating. This, and other lacquer damage, may be
repaired using a special senotherm lacquer spray available at all stove outlets.
Ash must be stored in a non-combustible container and must not be mixed with other combustible waste.
The combustion chamber is lined with Skamol. These panels will wear over time and will therefore need replacing. The same is true for the smoke plate.
A Skamol panel may crack if hit too hard by a piece of firewood. This has no effect on the function of the stove
(this is not the case with the smoke plate). The Skamol panels will only need to be replaced once they become
very worn and are no longer whole, or if they crack in several places.
The air damper and the stove door must be closed in the event of overheating.
OPERATING PROBLEMS
Soot forms on the window: The firewood may be too wet, or the intake of secondary air may be insufficient.
The wood burns too quickly: The chimney draft may be too strong, or there may be a leak near the door of the stove.
The stove fails to heat fully: The firewood may be too wet.
Smoke or odour: Weak chimney draft – check for blockages in the flue pipe/chimney and check the height of the
chimney in relation to the surroundings.
Soot in the chimney: The firewood may be too wet, or the intake of secondary air may be insufficient.
GUARANTEE
Your new stove is covered by a five year guarantee against manufacturing defects. Your receipt documents the
date of purchase. The guarantee does not cover damage caused by faulty operation such as overheating or the
stove being incorrectly connected, or damage which occurs as a result of external physical force.
The guarantee does not cover damage to replaceable parts, transport costs associated with repairs under warranty
or the installation/dismantling of the stove in connection with repairs under warranty.
Warning! Any unauthorised modification of the appliance is forbidden.
Only replacement parts recommended by Westfire ApS should be used for repairs.
8
UK
WESTFIRE · WF21
VERMICULITE FIRE BRICK INSTALLATION SEQUENCE – WESTFIRE UNIQ 21
Installation procedure:
Right inner top baffle brick 2 – positioned
on secondary air pipe & side supports.
1 – Left Inner Top Baffle Brick
2 – Right Inner Top Baffle Brick
3 – Rear Brick
4 – Left Base Brick
5 – Right Base Brick
6 – Left Angled Side Brick
7 – Right Angled Side Brick
8 – Left Side Brick
9 – Right Side Brick
10 – Top Baffle Brick
1.
2.
10.
3.
6.
8.
7.
4.
5.
9.
Left inner top baffle bricks 1 positioned on
secondary air pipe & side supports.
Left and right angled side bricks 6 &
7 fitted.
Right inner top baffle brick 2 – positioned
on secondary air pipe & side supports.
Left and right angled side bricks 6 &
7 fitted.
Top baffle bricks 2 & 3 fitted.
Left and right side bricks 8 & 9 fitted.
Rear brick 3 – line up tertiary air holes.
Front face of brick has smaller surface area.
Left and right side bricks 8 & 9 fitted.
Left & right base bricks 4 & 5 fitted – with
metal base brick tensioner positioned
at side.
Top baffle brick 10 (smallest straight edge
resting on top edge of rear brick) fitted
and supported with two side pins.
9
UK
WESTFIRE · WF21
UK: INSTALLATION MANUAL AND OPERATING INSTRUCTIONS
WESTFIRE WF UNIQ21 · WF UNIQ21 WALL HUNG · WF UNIQ21 PEDESTAL
This manual refers to the stove type listed above, which has been tested in accordance with EN 13240.
Congratulations on your purchase of a new wood burning stove from Westfire ApS. Please read this manual carefully in order to ensure that you get maximum enjoyment from your new stove and to prevent any problems.
Please note that “all local regulations, including those referring to national and European Standards, need to be
complied with when installing this appliance”.
For further information on installing and using fireplaces and wood burning stoves, please see the relevant building regulations that apply to the country in which UNIQ 21 has been approved, as well as the relevant documents
on the correct use of wood burning stoves available from your local stove supplier or your Chimney sweep.
These instructions cover the basic principles to ensure the satisfactory installation of the UNIQ 21 wood stove,
although detail may need slight modification to suit particular local site conditions.
In all cases the installation must comply with current Building Regulations, Local Authority Byelaws and other
specifications or regulations as they affect the installation of the stove.
It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS 8303, BS 6461 and BS 7566 as an alternative means to achieve an equivalent level of performance to that obtained following the guidance given in Approved Document J.
HEALTH AND SAFETY PRECAUTIONS
Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work
Act are met.
Handling
Adequate facilities must be available for loading, unloading and site handling.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of
contact, wash immediately with plenty of water.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation then
please seek specialist guidance and use appropriate protective equipment.
Metal Parts
When installing or servicing this stove care should be taken to avoid the possibility of personal injury.
WESTFIRE UNIQ 21 WOODSTOVE
UNIQ 21 dimensions
WF UNIQ 21
WF UNIQ 21 WALL HUNG
WF UNIQ 21 PEDESTAL
Height
800 mm
730 mm
1140mm
Width
440mm
440mm
440mm
Depth
430mm
450mm ( inc bracket)
430mm
Closed combustion option
YES
YES
YES
10
UK
WESTFIRE · WF21
STOVE PERFORMANCE & TESTING
Westfire WF UNIQ 21 has been approved in accordance with EN 13240.
Stove model
Weight
Nominal heat output
WF UNIQ 21 PEDESTAL
WF UNIQ 21
81KG
wood
Smokeless fuels
YES
N/A
WF UNIQ 21 WALL HUNG
WF UNIQ 21 PEDESTAL
81KG
YES
N/A
91KG
YES
N/A
PREPARATORY WORK AND SAFETY CHECKS
IMPORTANT WARNING
This stove must not be installed into a chimney that serves any other heating appliance.
There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes
into the room.
CHIMNEY
Chimney Connection
Flue Diameter 150mm (175cm2)
IMPORTANT: When installing the WF UNIQ 21 wood stove remove steel retaining bar across top flue exit. Remove
bolts and take out bar replace and bolt cast onto collar.
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate
draught so as to clear the products of combustion and prevent smoke problems into the room.
Minimum draft: WF UNIQ 21 stove has been tested with a draft of 12 Pa. Maximum draft 25 Pa.
Flue gas flow 4.2 g/sec.
Flue gas temperature 240°C. approximately 12 Pa.
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of
the chimney should be satisfactory. Alternatively the calculation procedure given in BS 5854:1980 may be used as
the basis for deciding whether a particular chimney design will provide sufficient draught.
The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J.
If installation is into an existing chimney then it must be sound and have no cracks or other faults which might
allow fumes into the house. Older properties, especially, may have chimney faults or the cross section may be
too large i.e. more than 160 mm x 160 mm. Remedial action should be taken, if required, seeking expert advice,
if necessary. If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in
accordance with Building Regulations Approved Document J.
Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of
the stove. If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and
the open fire.
If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations
Approved Document J or a twin walled insulated stainless steel flue to BS 4543 can be used. These chimneys must
be fitted in accordance with the manufacturer’s instructions and Building Regulations.
11
UK
WESTFIRE · WF21
A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for
the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its
dimension should be not less than the size of the outlet socket of the stove.
Any bend in the chimney or connecting fluepipe should not exceed 45°. 90° bends should not be used.
If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternatively
a draught stabiliser should be fitted. The adjustable flue damper should not close off the flue entirely but should
in its closed position leave a minimum continuous opening free area of at least 20 % of the total cross sectional
area of the flue or fluepipe.
Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping the chimney and
connecting flue pipe.
Distance to Combustible materials
Combustible materials should not be located where the heat dissipating through the walls of fireplaces or flues
could ignite it. Therefore when installing the stove in the presence of combustible materials due account must be
taken of the guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions.
WF UNIQ 21
Distance to combustible materials rear
175mm
Distance to combustible materials side
300mm
Distance to flammable material/furniture
800mm
Hearth
The hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not independently supported.
The Westfire WF UNIQ 21 wood stove has been tested and is suitable to be installed on a 12mm non combustible
plate such as Westfire 12mm glass plates or 20mm slate plates. Installation of all hearths should comply in size
and construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J.
The clearance distances to combustible material beneath, surrounding or upon the hearth and walls adjacent to
the hearth should comply with the guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions.
If the stove is to be installed on a wooden floor, it must be covered with a non-combustible material at least
12mm thick, in accordance with Building Regulations Approved Document J, to a distance of 30 cm in front of the
stove and 15 cm to each side measuring from the door of the combustion chamber.
Combustion air supply
In order for the stove to perform efficiently and safely there should be an adequate air supply into the room in
which the stove is installed to provide combustion air. This is particularly necessary if the room is double-glazed
or a flue draught stabiliser is operating in the same room as the appliance. The provision of air supply to the
stove must be in accordance with current Building Regulations Approved Document J. An opening window is not
appropriate for this purpose. Air inlets must be positioned in such a way that they cannot be blocked. An air inlet
may be a vent (the vent must be open and the capacity of the vent sufficient when the stove is lit) or a fresh air
system linked to the stove.
12
UK
WESTFIRE · WF21
WF UNIQ 21 stoves are available with a closed air supply collar (additional item) this enables the stove to take
combustion air directly from outside with a 100 mm pipe from the stove.
There are no European rules regarding the minimum distance to non-flammable walls, Westfire recommend leaving a gap of at least 10 cm behind and to sides of stove.
WF 21 Dimensions:
155mm
155mm
1140mm
800mm
1020mm
680mm
85mm
485mm
WF UNIQ 21
WF UNIQ 21 PEDESTAL
180mm
155mm
30mm
35mm
17mm
80mm
40mm
208mm
730mm
208mm
696mm
610mm
73mm
208mm
80mm
35mm
190mm
WF UNIQ 21 WALL HUNG
WF 21 WALL HUNG BRACKET
Top of bracket is 18mm below top of stove
Westfire Insulated chambers
The Westfire WF UNIQ 21 wood burning stove is lined with heat deflection panels and baffles, these panels are
designed to ensure the maximum efficiency and are an integral part of the clean burn process of the stove. These
baffles should not be removed apart from for cleaning the stove. Any defective panels should be replaced.
Connection to chimney
13
UK
WESTFIRE · WF21
Westfire WF UNIQ 21 wood stoves have both rear and top flue connector that allows connection to either a
masonry chimney or a prefabricated factory made insulated metal chimney in accordance with the instructions for
“Connection to chimney” given in the instruction booklet.
Commissioning and handover
Ensure loose parts are fitted in accordance with the instructions, page 15 & 16. ‘ Vermiculite fire brick installation
sequence’ before handover. Operation of primary and secondary air controls must be fully explained.
On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, when
a small fire may be lit and checked to ensure the smoke and fumes are taken from the stove up the chimney and
emitted safely to atmosphere. Do not run at full output for at least 24 hours.
On completion of the installation and commissioning ensure that the operating instructions for the stove are left
with the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be
used on the stove and warn them to use only the recommended fuels for the stove.
Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to
use a fireguard to BS 6539 in the presence of children, aged and/or infirm persons.
Operating your stove – WF UNIQ 21
Initial lighting
The heat-resistant paint on your stove will cure and harden the first time you light your appliance. The curing
process produces a good deal of smoke and odour, it is therefore important that the first time you light your stove
the room should be well ventilated. During the process it is important to open and close the stove door periodically (every 30mins) during the first couple of firings therefore preventing the door seal cord around the door
from sticking and coming away from the door. Once the Heat-resistant paint has hardened; the stove door must
be kept closed except when lighting the stove, adding firewood or removing ash in order to prevent flue gas from
escaping.
Lighting your appliance
Quality Firelighters should be used when lighting the stove. (Never use mentholated spirit, petrol or other flammable liquids). Lighting your stove with fire lighters will be more reliable and easier than paper.
To light your stove
1. Place a few smaller pieces of dry wood (kindling) in the stove on top of the non toxic firelighters.
2. Fully pull open the air slider (secondary air)
3. Light the firelighters and push door to closed position but do not close latch, door should remain open
approximately 1cm.
4. Once the fire has caught, add two pieces of wood measuring approx 20cm with a combined weight of
approx 1.4kg and close the door.
5. After approximately 10-15 minutes when the fire is burning brightly and hot closed the door fully. If the fire
falters and dies down unlatch door for another 5-10 mins.
6. After approximately another 10 minutes close the secondary air slider by 10% , for the stove to burn cleanly
plenty of secondary air is needed, do not be tempted to shut the fire down too early as this may cause smoke.
At nominal heat output, expect to refuel your stove approximately once an hour.
WF UNIQ 21, stoves are all equipped with a control valve for secondary air designed to ensure a plentiful supply
of oxygen during firing. When lit, the stove will get very hot and due care must therefore be exercised. Please use
a glove when operating levers and dampers.
RE-FUELING
To re-fuel in the cleanest way.
Before refuelling open secondary air value fully and leave for 5 minutes. Open door gently, add two pieces of
wood measuring approx 20cm with a combined weight of approx 1.4kg and close the door. Leave the air values
open for 10 minutes to allow the fire to reach a good temperature. Then close secondary air valve to 90% open.
In the event of a chimney fire: Close the air damper and the stove door, and call 999 or your local fire department.
If your stove is over heating close all dampers and door must be closed, and left until the stove has return to
nominal temperatures.
14
WESTFIRE · WF21
CONTROLS on WESTFIRE UNIQ 21
Pre-heated Tertiary air
Handle – Turn away from glass to open
Secondary air lever – push in for fully closed
– pull out for fully open
When lighting stove unlatch door 1 cm
to allow extra air into stove
Door operation
When opening the door of your Westfire stove always wear the glove that is provided to protect your hand from
possible heat. The handle twists right away from the fire. When shutting the door push the door closed and twist
left until the handle firmly closes.
WOOD FUEL
IMPORTANT: Never use toxic wood such as chipboard, impregnated, painted wood or finished prepared woods
such as pallet.
Good quality wood is the most important factor in your stove working efficiently and cleanly. Always use dry
firewood. The dryness of the firewood plays an important role since the use of wet wood results in poor fuel
economy and may cause a tarry sooty film on the internals of the stove.
Newly cut wood contains 60–70% water, making it totally unsuitable for use as firewood.
Newly cut wood should be stacked and air dried under cover for two years before being used as firewood.
SOLID SMOKELESS FUELS – Westfire stoves are only CE/EN/HETAS tested and approved for wood. It is possible,
however, to use other types of fuel with due care. When using coal/smokeless fuel you must use a coal insert and
a mix of 80% wood, 20% coal. Please note coal reduces the lifetime of the stove and the chimney considerably.
PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS STOVE; ITS USE WILL INVALIDATE THE GUARANTEE
Overnight burning
Westfire stoves are wood stoves, wood burns more efficiently and cleanly if is burnt hotter. Westfire do not recommend that their stoves are burnt overnight for this reason.
As a night time regime we recommend that the fire is loaded when hot and burnt for five minutes with the
secondary air valve fully open until the new wood has taken and is burning, then close the secondary air valve to
its operational position.
On returning to the stove in the morning the fire will have burn out, reload with some paper or firelighter and
some kindling and open all the values fully open and the stove will relight quickly. Beware as the ash bed will
have hot embers.
Use of operating tools
Always use the operating tools provided when handling parts likely to be hot when the stove is in use.
Maintenance
UNIQ 21 wood stove needs to have the ash removed from the stove at regular intervals. Make sure the stove is
completely cold before cleaning out ash (embers can remain hot for over 24 hours).
To clean the outside of the stove use a dry cloth.
Annual service
The inside of the stove should be serviced /cleaned once a year. To clean the inside, remove all ash, soot and tar
residue from the combustion chamber. Remove insulated chamber panels and baffle, dirt and soot will collect
15
UK
UK
WESTFIRE · WF21
behind it and this must be cleaned out. Check the quality of all insulated panels and replace any which are damaged or cracked, replace stove door rope cord in the door. Check glass is correctly positioned.
The stove, the flue pipe connection and the chimney should be checked regularly by a qualified engineer. The
chimney should also be checked for blockages before relighting the stove if it has not been used for an extended
period of time.
The paint/ lacquer can wear thin in exposed places due to overheating. This, and other lacquer damage, may be
repaired using a Westfire Senotherm paint/lacquer spray available from your Westfire dealer.
Ash must be stored in a non-combustible container and must not be mixed with other combustible waste.
TROUBLE SHOOTING, CHECK THE FOLLOWING:
1.Fire Will Not Burn
a) the air inlet is not obstructed in any way,
b) that chimneys and flueways are clear,
c) that a suitable fuel is being used,
d) that there is an adequate air supply into the room,
e) that an extractor fan is not fitted in the same room as the fire.
2.Fire Blazing Out Of Control
a) the doors are tightly closed,
b) the air control is turned down to the minimum setting,
c) the air inlet damper is closed and that it is not prevented from closing completely by a piece of ash,
d) a suitable fuel is being used,
e) the door seals are in good condition.
f) the chimney draft may be too strong
g) check ash pan seal and
h) check for ash below ash pan causing pan to not seat correctly and clean out.
3.Soot forms on the window
a) The firewood may be too wet
b) the intake of secondary air may be insufficient
c) fire not hot enough
4.The stove fails to heat fully
a) The firewood may be too wet
b) The intake of secondary air may be insufficient
5.Smoke or odour
a) Weak chimney draft
b) check for blockages in the flue pipe/chimney
c) check the height of the chimney in relation to the surroundings
6.Soot in the chimney
a) The firewood may be too wet
b) intake of secondary air may be insufficient
Chimney Fires
If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does
occur turn the air control setting to the minimum, and tightly close the doors of the stove. This should cause the
chimney fire to go out in which case the control should be kept at the minimum setting until the fire in the stove
has gone out. The chimney and flueways should then be cleaned. If the chimney fire does not go out when the
above action is taken then the fire brigade should be called immediately.
After a chimney fire the chimney should be carefully examined for any damage. Expert advice should be sought
if necessary.
16
WESTFIRE · WF21
Permanent air vent
The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently.
In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the
room in which the stove is installed to provide combustion air. This air vent should not under any circumstances
be shut off or sealed.
WARNING NOTE
Properly installed and maintained, this stove will not emit fumes into the dwelling during normal operation.
Occasional fume emissions may occur when removing ash and re fuelling. However, persistent fume emission is
potentially dangerous and must not be tolerated. If fume emission does persist, then the following immediate
action should be taken:
(a)
(b)
(c)
(d)
Open doors and windows to ventilate room
Let the fire out or eject and safely dispose of fuel from the appliance
Check for flue or chimney blockage and clean if required
Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected.
If necessary seek expert advice.
The most common cause of fume emission is flueway or chimney blockage. For your own safety these must be
kept clean at all times.
IMPORTANT NOTES
General
Before lighting the stove check with the installer that the installation work and commissioning checks described
in the installation instructions have been carried out correctly and that the chimney has been swept clean, is
sound and free from any obstructions. As part of the stoves’ commissioning and handover the installer should
have shown you how to operate the stove correctly.
Use of fireguard
When using the stove in situations where children, aged and/or infirm persons are present a fireguard must be used
to prevent accidental contact with the stove. The fireguard should be manufactured in accordance with BS 6539.
Chimney cleaning
The chimney should be swept at least once a year for smokeless fuels and a minimum of twice a year for wood
and other fuels. It is important that the flue connection and chimney are swept prior to lighting up after a prolonged shutdown period.
If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear
any soot falls which may have occurred due to the difference in combustion between the stove and the open fire.
In situations where it is not possible to sweep through the stove the installer will have provided alternative
means, such as a soot door. After sweeping the chimney the stove flue outlet and the flue pipe connecting the
stove to the chimney must be cleaned with a flue brush.
HETAS Ltd Approval
This appliance has obtained HETAS Ltd approval on a safe and fit for purpose level (single tick approval) for burning wood logs only as detailed in list of recommended fuels. Approval does not cover the use of other fuels either
alone or mixed, nor does it cover instructions for the use of other fuels.
Guarantee
Your new stove is covered by a five year guarantee against manufacturing defects. Your receipt documents the
date of purchase. The guarantee does not cover damage caused by faulty operation such as overheating or the
stove being incorrectly connected, or damage which occurs as a result of external physical force.
The guarantee does not cover damage to replaceable parts, transport costs associated with repairs under warranty
or the installation/dismantling of the stove in connection with repairs under warranty.
Warning! Any unauthorised modification of the appliance is forbidden.
Only replacement parts recommended by Westfire ApS should be used for repairs.
17
UK
14136 Mediegruppen Reklamebureau
Der tages forbehold for trykfejl
WESTFIRE 2009
24
Tømrervej 3 | DK-6800 Varde | telefon +45 7522 5352 | fax +45 7522 1352 | www.westfire.dk | e-mail: [email protected]