Download Movifit-FC - Operating Instructions
Transcript
Mechanical Installation Installation instructions 4 4 Mechanical Installation 4.1 Installation instructions • Mount MOVIFIT® only on a level, vibration-proof and torsionally rigid support structure, as described in the section "Approved installation position". • Use suitable cable glands (use reducing adapters if necessary). For versions with plug connectors, make sure to use the matching mating connectors. • Use screw plugs to seal cable entries not in use. • Use protective caps to seal plug connectors not in use. CAUTION Risk of injury due to protruding parts, especially the mounting rail. Risk of cutting or crushing. 4.2 • Cover sharp and protruding parts, especially the mounting rail, to protect against injury and damage. • Make sure that only trained specialists carry out the installation. Approved installation position The following figure depicts the approved installation position for MOVIFIT®. MOVIFIT® is attached by means of a mounting plate using the four screws already installed in the mounting surface. For further information, refer to section "Assembly instructions" (see page 21). 812409611 TIP This section uses the version with terminals and cable bushings as an example. However, the assembly instructions are applicable for all versions. 20 Operating Instructions – MOVIFIT®-FC