Download LED-246D User Manual

Transcript
11A
Innovation, Quality, Performance
Professional Entertainment Technology
User Manual
LED-246D
LED DUET RGBW
1A
30/60 days.
10A
y Clean the external optics at least every 20 days. Clean the internal optics at least every
y Always dry the parts carefully.
y Clean with soft cloth using normal glass cleaning fluid.
accumulation of dirt on the unit’s optics.
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
periodically to optimize light output. Cleaning frequency depends on the environment in
The cleaning of internal and external optical lenses and/or mirrors must be carried out
8. Fixture Cleaning
2. The motor’s drive IC on the PCB might be out of condition.
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
E. One of the channels is not working well
2. Check microphone to see if it is good by tapping the microphone.
1. Make sure the fixture does not receive DMX signal.
D. No response to the sound
2. Check if the unit is receiving DMX signal and cut it off.
1. Check the LED for the response of the master/ slave mode signal.
C. Some fixtures don’t respond to the easy controller
cause damage or interference to DMX interface circuit.
5. Check if the DMX cables run near or run alongside to high voltage cables that may
4. Try to use another DMX controller.
Check the connection of power and main fuse.
Measure the mains voltage on the main connector.
1.
2.
of the fixture or the previous one.
9A
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB
DMX polarity.
2. If the DMX LED is on and no response to the channel, check the address settings and
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
B. Not responding to DMX controller
The fixture does not work, no light
A.
suggestions for easy troubleshooting:
Following are a few common problems that may occur during operation. Here are some
7. Troubleshooting
Pin 4/5: Not used.
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
7. 3 pin XLR connectors are more popular than 5 pin XLR.
6. The end of the DMX 512 system should be terminated to reduce signal errors.
controller. The address number is between 0-512 (usually 0 & 1 are equal to 1).
5. Each lighting unit needs to have an address set to receive the data sent by the
circuit, when power is connected to the unit.
4. The DMX output and input connectors are pass-through to maintain the DMX
system.
joints or corroded connectors can easily distort the signal and shut down the
DMX 512 is a very high-speed signal. Inadequate or damaged cables, solder
to the input of the next unit. The cable can not be branched or split to a ‘Y’ cable.
3. Connect the unit together in a ‘daisy chain’ by XLR plug from the output of the unit
and plug it in the DMX-output of the last unit.
ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug
2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120
adapter-cable.
1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin
2A
8. Fixture Cleaning
7. Trouble Shooting
6. DMX 512 Connection
5. DMX 512 Configuration
4.4 Universal DMX controller
4.2 Easy controller
4.2 Master/Slave operation
4.1 Control Panel
4. How to Control the Unit
3. Installation
2. Technical Specification
1. Safety Instruction
TABLE OF CONTENTS
The unit must be installed in a location with adequate ventilation, at least 50cm from
y
Replace fuse only with the same type.
Make sure there are not flammable materials close to the unit while operating as it is fire
y
y
Do not look directly at the LED light beam while the fixture is on.
The housing must be replaced if they are visibly damaged.
Do not touch any wire during operation as high voltage might be causing electric shock.
y
y
y
3A
Don’t connect the device to any dimmer pack or power pack.
same type spare parts. .
please contact the nearest authorized technical assistance center and always use the
attempt any repairs by yourself. In the unlikely event your fixture may require service,
There are no user serviceable parts inside the fixture. Do not open the housing or
during its operation.
Unit surface temperature may reach up to 60℃. Don’t touch the housing bare-hand
y
y
y
Maximum ambient temperature is TA: 40℃ and don’t operate it where the temperature
y
is higher than this.
Use safety cable when fixes this unit.
y
hazard.
Disconnect mains power before fuse replacement or servicing.
y
adjacent surfaces. Be sure that no ventilation slots are blocked.
The unit is for indoor use only and use only in a dry location.
shock.
It’s important to ground the yellow/green conductor to earth in order to avoid electric
y
y
Before operating, ensure that the voltage and frequency of power supply match the
y
power requirements of the unit.
Unpack and check carefully there is no transportation damage before using the unit.
be sure that they also receive this instruction booklet.
Please keep this User Manual for future consultation. If you sell the unit to another user,
information about the installation, operation and maintenance.
y
y
WARNING
Please read the instruction carefully which including important
1. Safety Instruction
8A
The DMX 512 is widely used in intelligent lightings and with a maximum of 512 channels.
6. DMX 512 Connection
1
Value
2
#2
4
#3
1 Channel mode:
5. DMX 512 Configuration
Unit 4:dip / on: #3 (=4)
Unit 3:dip / on: #1,#2 (1+2=3)
Unit 2:dip / on: #2 (1+1=2)
Unit 1:dip / on: #1 (=1)
1 Channel mode: (Dip switch 10 off)
• Examples:
#1
Dip-switches
DMX 512 Address Chart:
8
#4
7A
16
#5
32
#6
64
#7
know how to address your DMX 512 system in the binary code.
128
#8
256
#9
2-Light show
#10
The dip switch 10 is used to choose channel mode. Please refer to the following diagram to
address by Dip switches from 1 to 9 to make sure all the units will receive its DMX signal.
When using a universal DMX controller to control the chain of units, you have to set DMX
4.4 Universal DMX Controller
LED: 2 x 10W LED
Power Consumption: 34.5W
Dimension: 344 x 350 x 152 mm
Weight: 5.0kg
y
y
y
4A
Ideal for all applications
y
y
Strong carrying handle, standing feet and hanging bracket for reliable operation
y
Fuse: T 6.3A
Optional easy controller CA-8 for instant lighting shows
y
y
Great built-in programs under Master/Slave triggered by music
y
Voltage: AC 100-240V~50/60Hz
Colorful RGBW spots like fireworks in the sky
y
y
Three operation modes: DMX, Master/Slave mode, Sound Active
column reflectors
Features double 10Watt high powered quad-color LEDs, two barrel reflectors and two
y
y
2. Technical Specification
OFF) In Master mode, Dipswitch 10 “on” means the unit runs in 1MSL mode and “Off”
means the unit runs in 1-CH mode.
Slave units: DMX start address may have any value but NOT 001 (example: set the first 3
DIP switches to ON)
firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure
to which you are attaching the unit is secure and is able to support a weight of 10 times of
the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the
unit when installing the fixture.
5A
perform the great built-in pre-programmed lighting shows triggered by music.
4.2 Master/Slave Operation
The unit can be linked together in daisy chain as many as you need in master/slave mode to
5 Dip switches:For different function setting.
○
Stand by, Function and Mode function.
1 DMX output: For DMX512 link, use 3/5-pin XLR plug cable to link the next unit.
○
2 DMX input: For DMX512 link, use 3/5-pin XLR plug cable to input DMX signal.
○
3 Power:Connect to input/output mains power.
○
4 Only for remote control: Connecting with CA-8/CA-9/CA-9RTX to control the unit for
○
4.3 Easy Controller (by CA-8/CA-9/CA-9RTX)
4.1 Control Panel
6A
Sound (LED OFF)
Function
Mode
Select color
Select Show
1–6
Red
Green
Blue
White
Red + Green
Red + Blue
Red + White
Green + Blue
Green + White
Blue + White
Red + Green + Blue
Red + Green + White
Red + Blue + White
Green + Blue + White
Red + Green + Blue +
White
16. Color change by sound
Manual Color (LED ON)
Show (LED slow
blinking)
Blackout the unit
Strobe
1. Synchronous strobe in 1.
white
2.
2. Sound strobe in white
3.
3. Sound strobe in color
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Blackout
selection
the first unit will control all the other units for Stand by, Function and Mode
to the 4-pin jack of the first unit, you will find that the remote controller on
The easy remote control is used only in master/slave mode. By connecting
master unit that operates the light show.
units only. Dipswitch 10 on the first (Master) unit is no use for the 2-light show as it is the
linking to the master unit to get contrast movement to the master unit, even if you have two
show. In order to create a great light show, you can set dip switch 10 ”on” on any unit that is
Dipswitch 10 ”off” means the unit works normally. And “on” means the unit runs 2-Light
4. How To Control The Unit
of the touch of people and has no one pass by or under it.
2-Light Show
Master unit: DMX start address MUST be set to 001. (First DIP switch = ON, all others are
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is
The equipment must be fixed by professionals. And it must be fixed at a place where is out
In Master/Slave mode refer to the DMX settings below:
3. Installation