(DMH110a) ENGLISH - WIRE IDENTIFICATION AND WIRING SCHEMATICS
52127
WIRING DIAGRAM NOTES:
1. The BOLD lines are what you should be connecting to the terminals
on this new thermostat.
2. The DASHED lines are optional depending upon your system type.
3, 4 WIRES
2
1-STAGE, COOLING ONLY
** Use “O” or “B”
Terminals, Never Both
Factory RH-RC Jumper Wire Installed
O
B
Y
3. In many cases, the thin lines shown as “SYSTEM COMMON” will
not be visible at the thermostat location, they are located with your
heating and cooling equipment.
W
RH
RC
G
C
Y
R
G
Y1
RC
F
6
V
4. For Heat Pumps, use the “B” or “O” wire, NOT BOTH. Typically
neither are used in a conventional system.
O
AIR
CONDITIONER
24V
POWER
1
HEATING ONLY (INCLUDING MILLIVOLT)
(2-WIRE HEAT USE “RH” & “W”)
4, 5 WIRES
O
B
Y
W
RH
RC
C
W
R
G
W1
RH
F
4
V
FAN WIRE
MAY NOT BE
PRESENT IN
ALL SYSTEMS
O
24V
POWER
Y
W
RH
G
W
R
G
X
Y1
W1
RH
F
B*
6
4
V
O
P
T
I
O
N
A
L
FAN
RC
F
V
24V
POWER
HEATER
REVERSING
VALVE
X
O
P
T
I
O
N
A
L
B*
24V
POWER
HEAT
PUMP
FAN
BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
5, 6 WIRES
5
1-STAGE HEATING AND 1-STAGE COOLING
WITH TWO SEPARATE 24V TRANSFORMERS
Factory RH-RC Jumper Wire REMOVED
O
B
Y
W
RH
RC
G
C
C
Y
W
RH
RC
G
X
Y1
W1
R
R
F
B*
6
4
V
V
O
P
T
I
O
N
A
L
FAN
C
X
B*
O
P
T
I
O
N
A
L
COMMON
AIR
CONDITIONER
BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
C
COMMON
3
COMMON
AIR
CONDITIONER
C
6
C
Y
G
Y1
FAN
RC
RC
X
O
P
T
I
O
N
A
L
C
COMMON
HEATER
B
RH
B*
B
Factory RH-RC Jumper Wire Installed
G
W
G
CONVENTIONAL (NON HEAT PUMP)
1-STAGE HEATING AND 1-STAGE COOLING
Factory RH-RC Jumper Wire Installed
Factory RH-RC Jumper Wire
Y
R
O
BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
2, 3, 4 WIRES
ADD Y-W Jumper Wire
Y
COMMON
6. If you have a “B” wire in your system which is used as a common
wire, connecting it to the “B” terminal on this thermostat may
damage your system and/or the thermostat.
B
C
5. If “Y” and “C” wires are both present, then “C” is a common wire.
4
SINGLE-STAGE HEAT PUMP SYSTEM
WITH NO AUX OR EMERGENCY HEAT
4, 5 WIRES
24V HEAT
POWER
HEATER
24V COOL
POWER
FAN
BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
(DMH110a) FRANÇAIS – IDENTIFICATION DES FILS ET SCHÉMAS DE CÂBLAGE
REMARQUES AU SUJET DES SCHÉMAS DE BRANCHEMENT :
1. Les lignes en GRAS représentent les fils que vous devriez connecter
aux bornes de ce nouveau thermostat.
2. Les traits TIRÉS sont optionnels d’après le type de votre système.
3. Dans de nombreux cas, les lignes minces marquées « SYSTÈME
COMMUN » ne seront pas visibles où le thermostat se trouve, car elles
se trouvent avec les appareils de chauffage et de climatisation.
4. Pour les pompes à chaleur, utilisez le fil « B » ou le fil « O », MAIS
PAS LES DEUX. Ceux-ci ne sont habituellement pas utilisés pour les
systèmes traditionnels.
5. Si « Y » et « C » sont tous les deux présents, alors « C » est un fil
commun.
6. Si un fil « B » de votre système est un fil commun, le connecter à la
borne « B » du thermostat pourrait endommager votre système et/ou le
thermostat.
2, 3, 4 FILS
1
CHAUFFAGE SEULEMENT (INCLUANT MILLIVOLT)
(CHAUFFAGE À 2 FILS UTILISEZ « RH » ou « W »)
3, 4 FILS
O
B
Y
W
B
Y
W
RH
R
W1
RH
4
V
G
C
O
Y
R
G
C
Y1
RC
F
X
6
V
B*
O
P
T
I
O
N
N
E
L
B
O
G
C
G
Y
F
X
B*
LE FIL DE
VENTILATEUR
N'EST PAS
NÉCESSAIREMENT
PRÉSENT DANS
TOUS LES
SYSTÈMES
W
ROBINET
INVERSEUR
VENTILATEUR
LES LETTRES DE NOIRES BORNES SONT TYPIQUES,
LES LETTRES DE BORNES GRISES SONT SPÉCIFIQUES SELON LA MARQUE
4, 5 FILS
O
P
T
I
O
N
N
E
L
Y
W
CLIMATISEUR
VENTILATEUR
RH
LES LETTRES DE NOIRES BORNES SONT TYPIQUES,
LES LETTRES DE BORNES GRISES SONT SPÉCIFIQUES SELON LA MARQUE
C
R
G
Y1
RC
F
6
V
O
P
T
I
O
N
N
E
L
C
X
B*
THERMOPOMPE
RC
G
3
5, 6 FILS
VENTILATEUR
5
CHAUFFAGE 1 ÉTAGE ET CLIMATISATION 1 ÉTAGE
AVEC DEUX TRANSFORMATEURS DISTINCTS 24 V
O
C
W
R
G
Y1
W1
RH
F
6
4
V
C
X
B*
COURANT
DE 24 V
COURANT
DE 24 V
Cavalier RH-RC d'usine RETIRÉ
Y
CHAUDIÈRE
G
LES LETTRES DE NOIRES BORNES SONT TYPIQUES,
LES LETTRES DE BORNES GRISES SONT SPÉCIFIQUES SELON LA MARQUE
TRADITIONNEL (NON PAS UNE THERMOPOMPE)
CHAUFFAGE 1 ÉTAGE ET CLIMATISATION 1 ÉTAGE
B
RC
Y
B
B
Y
O
P
T
I
O
N
N
E
L
W
RH
RC
G
C
Y
W
RH
RC
G
Y1
W1
R
R
F
6
4
V
V
O
P
T
I
O
N
N
E
L
C
X
B*
COMMUN
COMMUN
COURANT
DE 24 V
RH
COMMUN
COURANT
DE 24 V
CLIMATISEUR
O
C
INSTALLÉ PAR LE CLIENT Cavalier J-B
Cavalier RH-RC d'usine installé
COMMUN
COMMUN
CHAUDIÈRE
RC
Cavalier RH-RC d'usine installé
RC
W
RH
4
SYSTÈME À THERMOPOMPE UN ÉTAGE
AVEC SANS CHAUFFAGE AUX OU D'URGENCE
4, 5 FILS
** Utilisez des bornes « O » ou « B »,
mais non pas les deux
Cavalier RH-RC d'usine installé
Cavalier RH-RC d'usine installé
O
2
1 ÉTAGE, CLIMATISATION SEULEMENT
CLIMATISEUR
VENTILATEUR
LES LETTRES DE NOIRES BORNES SONT TYPIQUES,
LES LETTRES DE BORNES GRISES SONT SPÉCIFIQUES SELON LA MARQUE
COURANT DE
CHAUFFAGE
DE 24 V
CHAUDIÈRE
COURANT DE
CLIMATISATION
DE 24 V
VENTILATEUR
LES LETTRES DE NOIRES BORNES SONT TYPIQUES,
LES LETTRES DE BORNES GRISES SONT SPÉCIFIQUES SELON LA MARQUE
(DMH110a) ESPAÑOL – IDENTIFICACION DE CABLES Y DIAGRAMAS DE CABLEADO
COMENTARIOS SOBRE LOS DIAGRAMAS DE CABLEADO:
1. Las líneas RESALTADAS son las que debe conectar a los terminales
de este nuevo termostato.
2. Las líneas ENTRECORTADAS son opcionales de acuerdo con su tipo
de sistema.
3. En muchos casos, las líneas delgadas, que se indican como
“SISTEMA COMÚN”, no se pueden ver en el termostato porque se
encuentran en su equipo de calefacción y refrigeración.
4. Para las bombas de calor, use el alambre “B” u “O”, NO AMBOS.
Generalmente no se utiliza ninguno en un sistema convencional.
5. Si hay un alambre “Y” y un alambre “C”, el común será el alambre
“C”.
6. Si un alambre “B” en su sistema se utiliza como alambre común,
entonces conectarlo al terminal "B" del terminal del termostato puede
causar daños a su sistema y/o al termostato.
2, 3, 4 CABLES
1
SÓLO CALEFACCIÓN (INCLUYE MILIVOLTIOS)
(LA CALEFACCIÓN DE 2 CABLES USA "RH" Y "W")
3, 4 CABLES
Cable de puente RH-RC instalado de fábrica
O
B
B
Y
W
RH
RC
Y
W
G
C
R
G
Y1
RC
F
6
V
O
C
X
B*
O
P
C
I
O
N
A
L
B
O
G
C
R
G
AIRE
ACONDICIONADO
POTENCIA
DE 24V
W1
RH
F
4
V
PUEDE QUE
EL CABLE
DEL VENTILADOR
NO ESTÉ PRESENTE
EN TODOS LOS
SISTEMAS
X
B*
LAS LETRAS NEGRAS DE LAS TERMINALES SON TÍPICAS,
LAS LETRAS GRISES DE LAS TERMINALES SON ESPECÍFICAS DE CADA MARCA
W
RH
4, 5 CABLES
3
CONVENCIONAL (SIN BOMBA DE CALOR)
CALEFACCIÓN DE 1 FASE Y ENFRIAMIENTO DE 1 FASE
O
P
C
I
O
N
A
L
B
Y
W
AIRE
ACONDICIONADO
RH
RC
G
G
C
Y
R
G
Y1
RC
F
6
V
C
X
B*
O
P
C
I
O
N
A
L
W
R
G
Y1
W1
RH
F
6
4
V
5, 6 CABLES
O
C
X
B*
POTENCIA
DE 24V
BOMBA DE
CALEFACCIÓN
POTENCIA
DE 24V
VENTILADOR
CALEFACCIÓN DE 1 FASE Y ENFRIAMIENTO DE 1 FASE
CON DOS TRANSFORMADORES DE 24V POR SEPARADO
5
Cable de puente RH-RC de fábrica ELIMINADO
C
Y
CALENTADOR
RC
LAS LETRAS NEGRAS DE LAS TERMINALES SON TÍPICAS,
LAS LETRAS GRISES DE LAS TERMINALES SON ESPECÍFICAS DE CADA MARCA
O
P
C
I
O
N
A
L
B
Y
W
RH
RC
G
C
Y
W
RH
RC
G
Y1
W1
R
R
F
6
4
V
V
C
X
B*
O
P
C
I
O
N
A
L
COMUN
COMUN
VENTILADOR
B
VÁLVULA
DE INVERSIÓN
VENTILADOR
LAS LETRAS NEGRAS DE LAS TERMINALES SON TÍPICAS,
LAS LETRAS GRISES DE LAS TERMINALES SON ESPECÍFICAS DE CADA MARCA
O
C
Y
4
COMUN
Cable de puente RH-RC instalado de fábrica
W
POTENCIA
DE 24V
RC
Y
COMUN
CALENTADOR
RH
SISTEMA DE BOMBA DE CALOR DE FASE ÚNICA
CON NINGUNA CALEFACCIÓN AUX. NI DE EMERGENCIA
** Use la terminal "O" ó "B",
Cable de puente Y-W INSTALADO POR EL CLIENTE
nunca ambas
Cable de puente RH-RC instalado de fábrica
4, 5 CABLES
COMUN
Cable de puente RH-RC instalado de fábrica
O
2
1 ÉTAGE, CLIMATISATION SEULEMENT
VENTILADOR
LAS LETRAS NEGRAS DE LAS TERMINALES SON TÍPICAS,
LAS LETRAS GRISES DE LAS TERMINALES SON ESPECÍFICAS DE CADA MARCA
AIRE
ACONDICIONADO
CALENTADOR
POTENCIA DE POTENCIA DE VENTILADOR
CALEFACCIÓN ENFRIAMIENTO
DE 24V
DE 24V
LAS LETRAS NEGRAS DE LAS TERMINALES SON TÍPICAS,
LAS LETRAS GRISES DE LAS TERMINALES SON ESPECÍFICAS DE CADA MARCA