Download Active Ventilation RBSF-8-GR Installation Guide

Transcript
Installation Instructions: RBSF- Shingle Roof
1. Included in box (1) Round back Solar Fan (RBSF)
2. Before installing ( RBSF ), decide location to place opening.
Mark and cut opening *(cut at least two rows down from top
of shingle roof). Remove shingle
Top
only remove bottom shingle
5 watt
solar panel
Underside
3. Apply roofing grade sealant, silcone or tar on the underside
4. Place RBSF above opening by sliding flange in place
of flange.
underneath shingle. Using a #8 or #10 screw(or nails) should
be placed approximately a distance of 4 inch on center
on all 4 sides.
top half of flange should be
secured underneath shingles
sealant around perimeter
screws should be @ 4" on
center on all 4 sides
Active Ventilation Products, Inc.
311 First Street, Newburgh, NY 12550-4857
800-ROOF VENT (766-3836)
Website: roofvents.com
Ph: 845-565-7770
Fax: 845-562-8963