Transcript
Model: THD1035 Pre-Plumbed Laundry / Sink Tray System Ready To Install Installation Instructions 1. Use caution when opening the carton so you do not damage the unit, 2. Inlet Connection - Install an 1-1/2 in. PVC Schedule 40 threaded male adapter into the basins inlet hole as shown. This is the hole on the side of the lid. Use Teflon tape, silicon sealant or plumber's pipe dope to seal the threads. 3. Connect the inlet piping to the 1-1/2 in. PVC Schedule 40 threaded male adapter using PVC primer and solvent cement to properly seal the connection. 4. Referto Figures 2, 3 and 4 for typical installations configura- tions. 5. Discharge Connection - Install an 1-1/2 in. PVC Schedule 40 threaded male adapter into the sump pumps discharge hole as shown, Make sure that it is the sump pump discharge and not the vent port. Use Teflon tape, silicon sealant or plumber’s pipe dope to seal the threads. 6. Connect discharge pipe to the 1-122 in. PVC Schedule 40 threaded male adapter using PVC primer and solvent cement to properly seal the connection. We suggest that a union be in- stalled on this line to allow for easy pump service or removal. 7. Vent Connection - Install an 1-1/2 in. PVC Schedule 40 threaded male adapter into the vent hole as shown. Use Teflon tape, silicon sealant or plumber's pipe dope to seal the threads. 8. Connect vent pipe to the 1-122 in. PVC Schedule 40 threaded male adapter using PVC primer and solvent cement to properly seal the connection. Connect the vent pipe to the sewer's vent system. Once again, we suggest that a union be installed on this line to allow for easy pump service or removal, 9. Testthe system by filling the basin with water and running the pump through a complete cycle. ZN WARNING AN Risk of electrical shock. Do not handle pump or pump motor with wet hands. If basement floor is wet, do not walk on wet area until all power is turned off. If shut-off box is in basement, call the electric company to shut off service to the house, or call your local fire department for instructions. Re- move pump and repair or replace. Failure to follow this warning can result in fatal electrical shock. Always electrically ground pump motor to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway system, or to a ground wire system. Do not cut round grounding prong off of plug. Unplug pump before attempting to service or remove any component. Install according to local and national electrical codes. AN WARNING AN Do not use in explosive atmospheres. Pump water only with this pump. Failure to follow this waming can result in personal injury and/or property damage. Notice: Refer also to the Pump Owner's Manual for additional information. We suggest that a cena installed on the dischame vent pipes to allow i Toren + HE in РУС pump servios or rem peo 40 Pipe and 1-12 in PVC Toms Schedule 40 Pipa (Not included) Inci 1-1/2 in PVC To Schedule 40 threaded mate 1-122 in PVC adapter (Not Included) Cord Grommet Schedule 40 threaded male adapter G (Not incited) 1-12 in PVC Schedule e 5 40 threaded male ump Pump » adapter and pipe Discharge Pipe = (Not Inciuded) - Lid Gasket Basin wih id, kd gasicet, Sump Pump bolts and cord grommet Check Valve Pump Lock Plate - sis on bottom of basin locking pump in place 1/4 HP Sump Pump with Vertical Switch Figure 1 - Pre-Plumbed Laundry / Sink Tray System diagram amare Figure 2 - Installation for laundry sinks and washing machines rm ver (typical) м ~~ Y X A pes 20 A | ‘ + o {Г - | A NN 77 A | | \ ) j A WARNING A To prevent lint from the washing machine’s discharge from clogging the pump and causing a flood, cover the end of the discharge hose with a nylon stocking or a filter. WG Figure 3- Figure 4 - Installation for vet Installation to remove au conditioner bar (typical) condensate or hurmoñfier water > = n NAL. “ il [Е в ? ` A | Eo A 98. sa OS | LAT